Line 2: Line 2:
| number = ML070610273
| number = ML070610273
| issue date = 06/06/2007
| issue date = 06/06/2007
| title = Fort Calhoun Station, Unit 1 - Technical Specification Pages - Amendment No. 250 Adoption of TSTF-447 to Delete Requirements for Hydrogen Purge System - CLIIP (TAC No. MD3854)
| title = Technical Specification Pages - Amendment No. 250 Adoption of TSTF-447 to Delete Requirements for Hydrogen Purge System - CLIIP
| author name = Wang A B
| author name = Wang A
| author affiliation = NRC/NRR/ADRO/DORL/LPLIV
| author affiliation = NRC/NRR/ADRO/DORL/LPLIV
| addressee name = Ridenoure R T
| addressee name = Ridenoure R
| addressee affiliation = Omaha Public Power District
| addressee affiliation = Omaha Public Power District
| docket = 05000285
| docket = 05000285
| license number = DPR-040
| license number = DPR-040
| contact person = Wang A B, NRR/DORL/LPL4, 301-415-1445
| contact person = Wang A, NRR/DORL/LPL4, 301-415-1445
| case reference number = TAC MD3854
| case reference number = TAC MD3854
| package number = ML070610267
| package number = ML070610267
Line 19: Line 19:


=Text=
=Text=
{{#Wiki_filter:TECHNICAL SPECIFICATIONS
{{#Wiki_filter:TECHNICAL SPECIFICATIONS 2.0 LIMITING CONDITIONS FOR OPERATION 2.6 Containment System (Continued)
: c.
DELETED
: d.
The containment isolation valves VA-280 and VA-289 shall be locked closed. Opening of these valves intermittently under administrative control is not allowed.
: e.
The containment purge isolation valves will be locked closed unless the reactor is in a cold or refueling shutdown condition.
(2)
Internal Pressure The internal pressure shall not exceed 3 psig (except for containment leak rate tests).
2.6 - Page 2 Amendment No. 68,139,151,188 250


===2.0 LIMITING===
TECHNICAL SPECIFICATIONS TABLE 3-5 MINIMUM FREQUENCIESFOR EQUIPMENT TESTS Test Frequency
CONDITIONS FOR OPERATION 2.6 Containment System (Continued)
: 17.
: c. DELETED d. The containment isolation valves VA-280 and VA-289 shall be locked closed. Opening of these valves intermittently under administrative control is not allowed.e. The containment purge isolation valves will be locked closed unless the reactor is in a cold or refueling shutdown condition.
DELETED
(2) Internal Pressure The internal pressure shall not exceed 3 psig (except for containment leak rate tests).2.6 -Page 2 Amendment No. 68,139,151,188 250 TECHNICAL SPECIFICATIONS TABLE 3-5 MINIMUM FREQUENCIESFOR EQUIPMENT TESTS Test Frequency 17. DELETED 18. Shutdown Cooling 1. Verify required shutdown cooling loops are OPERABLE and one shutdown cooling loop is IN OPERATION.
: 18.
: 2. Verify correct breaker alignment and indicated power is available to the required shutdown cooling pump that is not IN OPERATION.
Shutdown Cooling
S (when shutdown cooling is required by TS 2.8).W (when shutdown cooling is required by TS 2.8).312 -Page 12-Page 12Amendment No. 438,1.69,188, 246 250}}
: 1.
Verify required shutdown cooling loops are OPERABLE and one shutdown cooling loop is IN OPERATION.
: 2.
Verify correct breaker alignment and indicated power is available to the required shutdown cooling pump that is not IN OPERATION.
S (when shutdown cooling is required by TS 2.8).
W (when shutdown cooling is required by TS 2.8).
312 - Page 12
- Page 12Amendment No. 438,1.69,188, 246 250}}

Latest revision as of 03:01, 15 January 2025

Technical Specification Pages - Amendment No. 250 Adoption of TSTF-447 to Delete Requirements for Hydrogen Purge System - CLIIP
ML070610273
Person / Time
Site: Fort Calhoun 
Issue date: 06/06/2007
From: Wang A
NRC/NRR/ADRO/DORL/LPLIV
To: Ridenoure R
Omaha Public Power District
Wang A, NRR/DORL/LPL4, 301-415-1445
Shared Package
ML070610267 List:
References
TAC MD3854
Download: ML070610273 (2)


Text

TECHNICAL SPECIFICATIONS 2.0 LIMITING CONDITIONS FOR OPERATION 2.6 Containment System (Continued)

c.

DELETED

d.

The containment isolation valves VA-280 and VA-289 shall be locked closed. Opening of these valves intermittently under administrative control is not allowed.

e.

The containment purge isolation valves will be locked closed unless the reactor is in a cold or refueling shutdown condition.

(2)

Internal Pressure The internal pressure shall not exceed 3 psig (except for containment leak rate tests).

2.6 - Page 2 Amendment No. 68,139,151,188 250

TECHNICAL SPECIFICATIONS TABLE 3-5 MINIMUM FREQUENCIESFOR EQUIPMENT TESTS Test Frequency

17.

DELETED

18.

Shutdown Cooling

1.

Verify required shutdown cooling loops are OPERABLE and one shutdown cooling loop is IN OPERATION.

2.

Verify correct breaker alignment and indicated power is available to the required shutdown cooling pump that is not IN OPERATION.

S (when shutdown cooling is required by TS 2.8).

W (when shutdown cooling is required by TS 2.8).

312 - Page 12

- Page 12Amendment No. 438,1.69,188, 246 250