| event date = 05/08/2004 04:50 CDT | | event date = 05/08/2004 04:50 CDT | ||
| last update date = 05/08/2004 | | last update date = 05/08/2004 | ||
| title = Reactor Startup Cancelled Due | | title = Reactor Startup Cancelled Due to Erratic Source Range Monitor | ||
| event text = While performing a unit start-up, SRM 24 was declared inoperable due to erratic indications. SRM 22 was already inoperable which resulted in falling below the Technical Specification 3.3.1.2 mode 2 requirement of 3 operable SRMs. | | event text = While performing a unit start-up, SRM 24 was declared inoperable due to erratic indications. SRM 22 was already inoperable which resulted in falling below the Technical Specification 3.3.1.2 mode 2 requirement of 3 operable SRMs. | ||
The cause of the erratic indications on SRM 24 is unknown at this time. All control rods were fully inserted at 0527 CDT. | The cause of the erratic indications on SRM 24 is unknown at this time. All control rods were fully inserted at 0527 CDT. |
Latest revision as of 21:23, 1 March 2018
Where | |
---|---|
Dresden Illinois (NRC Region 3) | |
Reporting | |
10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown | |
Time - Person (Reporting Time:+-2.72 h-0.113 days <br />-0.0162 weeks <br />-0.00373 months <br />) | |
Opened: | Scott Briley 07:07 May 8, 2004 |
NRC Officer: | John Mackinnon |
Last Updated: | May 8, 2004 |