| Title | Offsite Notification Due to Inadvertent Activation of Emergency Sirens |
| Event Description | The following information was obtained from the licensee via facsimile:
At 0912 [EDT] the Salem Township sirens, zone 14, sounded for 3 minutes. All ten sirens in zone 14 sounded. The reason for the siren sounding was unknown at that time. The Sheriff Dispatcher notified Emergency Preparedness of the sirens sounding. Emergency Preparedness called the vendor, Transco, to investigate the siren sounding. Transco went to the 500 [foot] siren tower and polled the siren system and found that the Zone 14 sirens had been activated by a signal from the Sheriff Dispatch office at 0912 [hrs.]. Transco then went to the Sheriff Dispatch office to look at the system and found no problems. At 1158 [hrs.], on 5/8/04, a quiet test, e.g. low noise level test, was conducted for siren 91, next to the Sheriff's office, to ensure the siren system was operating properly. Discussions with the Sheriff Dispatchers indicated that they were not in the vicinity of the siren console and did not have the siren screen called up. Therefore, it was not possible for the Sheriff Dispatchers to inadvertently activate the sirens. The only other activity in the siren console area was an exterminator working. Therefore, at this time, the most likely cause of the sirens sounding is the exterminator inadvertently activating the Zone 14 sirens. The Prompt Notification System (sirens) were verified capable of performing [their] intended function (operable), at no time was Emergency Notification capability impaired, it was also validated, that once activated by the inadvertent action, the system responded as expected. This spurious activation does not appear in any way to be related to Event #40734 regarding the test failure on May 7, 2004. The licensee has notified the NRC Resident Inspector. |
| Where | |
|---|---|
| Davis Besse Ohio (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release | |
| Time - Person (Reporting Time:+-1.45 h-0.0604 days <br />-0.00863 weeks <br />-0.00199 months <br />) | |
| Opened: | Art Lewis 15:58 May 8, 2004 |
| NRC Officer: | Howie Crouch |
| Last Updated: | May 8, 2004 |
| 40736 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 564132023-03-15T13:50:00015 March 2023 13:50:00
[Table view]10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Inadvertent Actuation of Emergency Sirens ENS 547922020-07-20T00:03:00020 July 2020 00:03:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Emergency Siren Failure ENS 542192019-08-14T16:01:00014 August 2019 16:01:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertant Activation of Emergency Sirens ENS 493692013-09-20T18:00:00020 September 2013 18:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Press Release Notification ENS 465762011-01-31T13:49:00031 January 2011 13:49:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Emergency Notification System Sirens Inadvertantly Actuated for 3 Minutes ENS 457642010-03-13T02:43:00013 March 2010 02:43:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Control Rod Drive Mechanism Nozzle Indications ENS 455232009-11-27T12:34:00027 November 2009 12:34:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Accidental Discharge of a Security Officer'S Pistol ENS 450322009-04-30T12:55:00030 April 2009 12:55:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notifications Made Due to Inadvertant Activation of Six Epz Sirens ENS 445962008-10-23T13:00:00023 October 2008 13:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Sump Discharge Line Leakage ENS 422762006-01-20T16:25:00020 January 2006 16:25:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Press Release Issued Regarding Agreement with Doj Related to Davis-Besse Reactor Head Issue ENS 409062004-07-29T15:03:00029 July 2004 15:03:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Industrial Accident on the Owner Controlled Area ENS 407362004-05-08T17:25:0008 May 2004 17:25:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Inadvertent Activation of Emergency Sirens 2023-03-15T13:50:00 | |