| event date = 02/21/2005 02:50 EST
| event date = 02/21/2005 02:50 EST
| last update date = 02/21/2005
| last update date = 02/21/2005
| title = Safety Parameter Display System Inoperable For Greater Than One Hour
| title = Safety Parameter Display System Inoperable for Greater than One Hour
| event text = On February 21, 2005, at 0250 hours [EST], the Unit 1 Plant Computer System (PCS) failed rendering the Safety Parameter Display System (SPDS) inoperable.  The PCS and SPDS were restored at 0650 hours.  This event is a major loss of emergency assessment capability for greater than one hour and is reportable under 10 CFR 50.72(b)(3)(xiii).
| event text = On February 21, 2005, at 0250 hours [EST], the Unit 1 Plant Computer System (PCS) failed rendering the Safety Parameter Display System (SPDS) inoperable.  The PCS and SPDS were restored at 0650 hours.  This event is a major loss of emergency assessment capability for greater than one hour and is reportable under 10 CFR 50.72(b)(3)(xiii).
The licensee will notify the NRC Resident Inspector.
The licensee will notify the NRC Resident Inspector.

Latest revision as of 22:21, 1 March 2018

ENS 41426 +/-
Where
North Anna Dominion icon.png
Virginia (NRC Region 2)
Reporting
10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness
Time - Person (Reporting Time:+1.78 h0.0742 days <br />0.0106 weeks <br />0.00244 months <br />)
Opened: Page Kemp
09:37 Feb 21, 2005
NRC Officer: Mike Ripley
Last Updated: Feb 21, 2005
41426 - NRC Website