| event date = 09/18/2013 12:59 EDT
| event date = 09/18/2013 12:59 EDT
| last update date = 10/31/2013
| last update date = 10/31/2013
| title = High Pressure Coolant Injection System Declared Inoperable Due To Steam Leak
| title = High Pressure Coolant Injection System Declared Inoperable Due to Steam Leak
| event text = On 9/18/13, during performance of the High Pressure Coolant Injection (HPCI) pump operability surveillance, a minor steam leak was discovered on the governor valve inspection cover flange.  Due to the leak, HPCI was declared inoperable.
| event text = On 9/18/13, during performance of the High Pressure Coolant Injection (HPCI) pump operability surveillance, a minor steam leak was discovered on the governor valve inspection cover flange.  Due to the leak, HPCI was declared inoperable.
Actions taken: A 14-day LCO per TS 3.5.E.2 has been entered and corrective actions are in progress.
Actions taken: A 14-day LCO per TS 3.5.E.2 has been entered and corrective actions are in progress.

Latest revision as of 21:52, 1 March 2018

ENS 49355 +/- *RETRACTED*
Where
Vermont Yankee Entergy icon.png
Vermont (NRC Region 1)
Reporting
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident
Time - Person (Reporting Time:+1.82 h0.0758 days <br />0.0108 weeks <br />0.00249 months <br />)
Opened: James Kritzer
18:48 Sep 18, 2013
NRC Officer: Howie Crouch
Last Updated: Oct 31, 2013