ENS 50157: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 05/30/2014 10:00 MDT
| event date = 05/30/2014 10:00 MDT
| last update date = 06/05/2014
| last update date = 06/05/2014
| title = Agreement State Report - Radiography Camera Source Failed To Retract
| title = Agreement State Report - Radiography Camera Source Failed to Retract
| event text = After attempting to retract the source during radiography operations, the radiographer noticed elevated radiation levels.  The radiographer set up a boundary and notified the RSO.  The RSO determined that the source was not fully retracted but was able to retract the source. The RSO was in a 40 mr/hr area for about 5 minutes.  The licensee will send the camera to the manufacturer for repair.
| event text = After attempting to retract the source during radiography operations, the radiographer noticed elevated radiation levels.  The radiographer set up a boundary and notified the RSO.  The RSO determined that the source was not fully retracted but was able to retract the source. The RSO was in a 40 mr/hr area for about 5 minutes.  The licensee will send the camera to the manufacturer for repair.
Exposure Device:
Exposure Device:

Latest revision as of 20:50, 1 March 2018

ENS 50157 +/-
Where
Premier Ndt
Rangely, Colorado (NRC Region 4)
License number: 116201
Organization: Colorado Dept Of Health
Reporting
Agreement State
Time - Person (Reporting Time:+-2.18 h-0.0908 days <br />-0.013 weeks <br />-0.00299 months <br />)
Opened: Cheri Hall
13:49 May 30, 2014
NRC Officer: Dong Park
Last Updated: Jun 5, 2014
50157 - NRC Website