ENS 50157: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
| Line 16: | Line 16: | ||
| event date = 05/30/2014 10:00 MDT | | event date = 05/30/2014 10:00 MDT | ||
| last update date = 06/05/2014 | | last update date = 06/05/2014 | ||
| title = Agreement State Report - Radiography Camera Source Failed | | title = Agreement State Report - Radiography Camera Source Failed to Retract | ||
| event text = After attempting to retract the source during radiography operations, the radiographer noticed elevated radiation levels. The radiographer set up a boundary and notified the RSO. The RSO determined that the source was not fully retracted but was able to retract the source. The RSO was in a 40 mr/hr area for about 5 minutes. The licensee will send the camera to the manufacturer for repair. | | event text = After attempting to retract the source during radiography operations, the radiographer noticed elevated radiation levels. The radiographer set up a boundary and notified the RSO. The RSO determined that the source was not fully retracted but was able to retract the source. The RSO was in a 40 mr/hr area for about 5 minutes. The licensee will send the camera to the manufacturer for repair. | ||
Exposure Device: | Exposure Device: | ||
Latest revision as of 20:50, 1 March 2018
| Where | |
|---|---|
| Premier Ndt Rangely, Colorado (NRC Region 4) | |
| License number: | 116201 |
| Organization: | Colorado Dept Of Health |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+-2.18 h-0.0908 days <br />-0.013 weeks <br />-0.00299 months <br />) | |
| Opened: | Cheri Hall 13:49 May 30, 2014 |
| NRC Officer: | Dong Park |
| Last Updated: | Jun 5, 2014 |
| 50157 - NRC Website | |