| title = Agreement State Report - Fixed Nuclear Gauge Shutter Failed To Close
| title = Agreement State Report - Fixed Nuclear Gauge Shutter Failed to Close
| event text = The following information was received via E-mail:
| event text = The following information was received via E-mail:
The licensee reported that a shutter on a fixed gauge (Isotope Measuring Systems, Inc. model 5221-02) containing five (5) five curies of Americium-241 sealed sources had one of the five shutters on the device fail to close during device calibration on January 9, 2018. This failure was reported to the Iowa Department of Public Health (IDPH) on January 10, 2018. The licensee has contacted the manufacturer and a service representative will arrive on site Thursday, January 11, 2018 to assess the cause of the shutter failure. IDPH will provide additional information to the NRC after receiving the manufacturer service representatives field report.
The licensee reported that a shutter on a fixed gauge (Isotope Measuring Systems, Inc. model 5221-02) containing five (5) five curies of Americium-241 sealed sources had one of the five shutters on the device fail to close during device calibration on January 9, 2018. This failure was reported to the Iowa Department of Public Health (IDPH) on January 10, 2018. The licensee has contacted the manufacturer and a service representative will arrive on site Thursday, January 11, 2018 to assess the cause of the shutter failure. IDPH will provide additional information to the NRC after receiving the manufacturer service representatives field report.

Revision as of 21:41, 1 March 2018

ENS 53163 +/-
Where
Arconic Davenport Works
Bettendorf, Iowa (NRC Region 3)
License number: 0169-1-82-Fg
Organization: Iowa Department Of Public Health
Reporting
Agreement State
Time - Person (Reporting Time:+33.32 h1.388 days <br />0.198 weeks <br />0.0456 months <br />)
Opened: Randal Dahlin
15:19 Jan 10, 2018
NRC Officer: Donald Norwood
Last Updated: Jan 10, 2018
53163 - NRC Website