VOGTLE ELECTRIC GENERATING PLANT                                   l UNITS 1 & 2 SECOND 10 -YEAR INTERVAL PUMP INSERVICE TEST PROGRAM R                                                     ITS       ITS   ITS   VNMS E     DATE                 DESCRIPTION               PREP'D   REV'D APPV'D APPV'D V                                                       BY       BY   BY     BY 0   12/06/96 INITIAL ISSUE TO VEGP FOR REVIEW & APPROVAL.                                         #
VOGTLE ELECTRIC GENERATING PLANT UNITS 1 & 2 SECOND 10 -YEAR INTERVAL PUMP INSERVICE TEST PROGRAM R
VEGP IST APPROVAL IST Eng             J --       'I         6/co/e-l Engr. Supv:         /         104tre         97-97 Mgr. Engr:               [ 4%d               .5 'M/ 2 ANQ:     'd                 pf{w           JhGX phA ZfErg, _ J 9 7 PRB: Mtg. No:           Mb9               30             JA   .
ITS ITS ITS VNMS E
                            ,5lsMg
DATE DESCRIPTION PREP'D REV'D APPV'D APPV'D V
                                                    / j'     [ / I' Date:    _
BY BY BY BY 0
12/06/96 INITIAL ISSUE TO VEGP FOR REVIEW & APPROVAL.
VEGP IST APPROVAL IST Eng J --
'I 6/co/e-l Engr. Supv:
/
104tre 97-97 Mgr. Engr:
[
4%d
.5 'M/ 2 ANQ:
'd pf{w JhGX phA ZfErg, _
J 9 7 PRB: Mtg. No:
Mb9 30 JA Date:
,5lsMg j'
[ / I'
/
Gen. Mgr:
Gen. Mgr:
t C ,,
C,,
O [$     7
O [$
                                                          /
7 t
l 9706030209 970529 PDR   ADOCK 05000424 P                     PDR Vogtle Electric Generating Plant Route 2, Box 299-A Waynesboro, GA 30830
l
                                      *) ' 10\
/
9706030209 970529 PDR ADOCK 05000424 P
PDR Vogtle Electric Generating Plant Route 2, Box 299-A Waynesboro, GA 30830
*) ' 10\\


i DISTRIBUTION LIST                             I l
DISTRIBUTION LIST l
1 IIOLDER                         _
IIOLDER MANUAL NUMBER K. G. Lowery (SCS) 1 1
MANUAL NUMBER K. G. Lowery (SCS)                                               1               1 T. M. Hickox                                                     2 J. J. Churchwell                                                 3 l
T. M. Hickox 2
SNC Site Document Control Supervisor                             4 SNC Site Perfbrmance Supervisor                                 5               i K. L. Glandon                                                   6               l J. C. McWimrter                                                 7 ITS Department Shelf Copy                                       8 O
J. J. Churchwell 3
l Rev.O
SNC Site Document Control Supervisor 4
SNC Site Perfbrmance Supervisor 5
i K. L. Glandon 6
J. C. McWimrter 7
ITS Department Shelf Copy 8
O l
Rev.O


TABLE OF CONTENTS (See Active Page List for Current Revision)
TABLE OF CONTENTS (See Active Page List for Current Revision)
O SECTION PAGES PROGRAM INTRODUCTION                                               1-1 thm 1-2 ABBREVIATIONS LIST                                                 2-1 thm 2-2 PUMP INTRODUCTION                                                 3-1 thm 3-9 VEGP 1 PUMP TABLES                                                 4-1 thm 4-8     ]
O SECTION PAGES PROGRAM INTRODUCTION 1-1 thm 1-2 ABBREVIATIONS LIST 2-1 thm 2-2 PUMP INTRODUCTION 3-1 thm 3-9 VEGP 1 PUMP TABLES 4-1 thm 4-8
NSCW PUMPS                                                         5-1 thm 5-10 NSCW PUMP TEST DIAGRAMS                                     8 pages         l CCW PUMPS                                                         6-1 thm 6-7     l CCW PUMP TEST DIAGRAMS                                       A pages S1 PUMPS                                                           7-1 thm 7-3 S1 PUMP TEST DIAGRAMS                                       2 pages I
]
RHR PUMPS                                                         8-1 thm 8-3 RHR PUMP TEST DIAGRAMS                                       2 pages CS PUMPS                                                           9-1 thm 9-3 CS PUMP TEST DIAGRAMS                                       2 pages CVCS PUMPS                                                         10-1 thm 10-3 CVCS PUMP TEST DIAGRAMS                                     2 pages BAT PUMPS                                                         11-1 thm 11-3 BAT PUMP TEST DI AGRAMS                                     2 pages AFW PUMPS                                                           12-1 thru 12-6 AFW PUMP TEST DIAGRAMS                                       3 pages ESF PUMPS                                                           13-1 thru 13-3 ESF PUMP TEST DIAGRAMS                                       2 pages VEGP-2 PUMP TABLES                                                 14-1 thru 14-8 NSCW PUMPS                                                         15-1 thm 15-10 NSCW PUMP TEST DIAGRAMS                                     8 pages CCW PUMPS                                                           16-1 thru 16-7 CCW PUMP TEST DIAGRAMS                                       6 pages Page1of2
NSCW PUMPS 5-1 thm 5-10 NSCW PUMP TEST DIAGRAMS 8 pages l
CCW PUMPS 6-1 thm 6-7 CCW PUMP TEST DIAGRAMS A pages S1 PUMPS 7-1 thm 7-3 S1 PUMP TEST DIAGRAMS 2 pages RHR PUMPS 8-1 thm 8-3 RHR PUMP TEST DIAGRAMS 2 pages CS PUMPS 9-1 thm 9-3 CS PUMP TEST DIAGRAMS 2 pages CVCS PUMPS 10-1 thm 10-3 CVCS PUMP TEST DIAGRAMS 2 pages BAT PUMPS 11-1 thm 11-3 BAT PUMP TEST DI AGRAMS 2 pages AFW PUMPS 12-1 thru 12-6 AFW PUMP TEST DIAGRAMS 3 pages ESF PUMPS 13-1 thru 13-3 ESF PUMP TEST DIAGRAMS 2 pages VEGP-2 PUMP TABLES 14-1 thru 14-8 NSCW PUMPS 15-1 thm 15-10 NSCW PUMP TEST DIAGRAMS 8 pages CCW PUMPS 16-1 thru 16-7 CCW PUMP TEST DIAGRAMS 6 pages Page1of2


Table of Contents (cont.)
Table of Contents (cont.)
S1 PUMPS                                               17-1 thru 17-3
S1 PUMPS 17-1 thru 17-3 SI PUMP TEST DIAGRAMS 2 pages RHR PUMPS 18-1 thm 18-3 RHR PUMP TEST DIAGRAMS 2 pages 1
,          SI PUMP TEST DIAGRAMS                           2 pages RHR PUMPS                                               18-1 thm 18-3 RHR PUMP TEST DIAGRAMS                           2 pages           1 CS PUMPS                                               19-1 thru 19-3   l CS PUMP TEST DIAGRAMS                           2 pages CVCS PUMPS                                             20-1 thru 20-3 CVCS PUMP TEST DIAGRAMS                         2 pages BAT PUMPS                                               21-1 thru 21-3 BAT PUMP TEST DIAGRAMS                           2 pages AFW PUMPS                                               22-1 thm 22-6 AFW PUMP TEST DIAGRAMS                           3 pages l
CS PUMPS 19-1 thru 19-3 CS PUMP TEST DIAGRAMS 2 pages CVCS PUMPS 20-1 thru 20-3 CVCS PUMP TEST DIAGRAMS 2 pages BAT PUMPS 21-1 thru 21-3 BAT PUMP TEST DIAGRAMS 2 pages AFW PUMPS 22-1 thm 22-6 AFW PUMP TEST DIAGRAMS 3 pages ESF PUMPS 23-1 thru 23-3 i
ESF PUMPS                                               23-1 thru 23-3   i ESF PUMP TEST DIAGRAMS                           2 pages RELIEF REQUESTS                                         24-1 thru 24-5 O
ESF PUMP TEST DIAGRAMS 2 pages RELIEF REQUESTS 24-1 thru 24-5 Ob l
b l
O L)
l O
L)
Page 2 of 2
Page 2 of 2


1 ACTIVF PAGE LIST Pane No. Rev. No.       Page No.       Rev. No.
1 ACTIVF PAGE LIST Pane No.
(
Rev. No.
  '( )s 1-1         0       -
Page No.
6-6             0                           '
Rev. No.
l-2         0               6-7             0 2-1         0               ISI-D-209       2 2-2         0               ISI-D-210       2 3-1         0               ISI-D-211       2 3-2         0               ISI-D-212       2 3-3         0               ISI-D-213       2                           I 3-4         0               ISI-D-214       2 3-5         0               7-1             0 3-6         0               7-2             0 3-7         0               7-3             0                           !
('( )s 1-1 0
3-8         0               ISI-D-215       3 3-9         0               ISI-D-216       3                           1 4-1         0               8-1             0 4-2         0               8-2             0 4-3         0               8-3             0 4-4         0               ISI-D-217       6 4-5         0               ISI-D-218       6 4-6         0               9-1             0 4-7         0               9-2             0 4-8         0               9-3             0 (j   5-1         0               ISI-D-219       3 5't         0               ISI-D-220       3 5-3         0               10 - 1         0 5-4         0               10 - 2         0 5-5         0               10 -3           0 5-6         0               ISI-D-221       5 5       0               ISI-D-222       5
6-6 0
,        5-8         0               11-1           0 5-9         0               11 - 2         0 5 - 10     0               11 - 3         0 ISI-D-201   2               ISI-D-228       3
l-2 0
,        ISI-D-202   2               ISI-D-229       3 ISI-D-203   2               12-1           0 ISI-D-204   2               12- 2         0 ISI-D-205   2               12- 3         0 ISI-D-206   2               12-4           0 ISI-D-207   3               12- 5         0
6-7 0
,      ISI-D-208   3               12- 6         0 6-1         0               ISI-D-223       2 6-2         0               ISI-D-224       2 6-3         0               ISI-D-225       2 6-4         0               13 - 1         0
2-1 0
(]s  6-5         0               13 - 2         0 Page 1 of 2             Updated 04/28/97
ISI-D-209 2
2-2 0
ISI-D-210 2
3-1 0
ISI-D-211 2
3-2 0
ISI-D-212 2
3-3 0
ISI-D-213 2
3-4 0
ISI-D-214 2
3-5 0
7-1 0
3-6 0
7-2 0
3-7 0
7-3 0
3-8 0
ISI-D-215 3
3-9 0
ISI-D-216 3
4-1 0
8-1 0
4-2 0
8-2 0
4-3 0
8-3 0
4-4 0
ISI-D-217 6
4-5 0
ISI-D-218 6
4-6 0
9-1 0
4-7 0
9-2 0
4-8 0
9-3 0
(j 5-1 0
ISI-D-219 3
5't 0
ISI-D-220 3
5-3 0
10 - 1 0
5-4 0
10 - 2 0
5-5 0
10 -3 0
5-6 0
ISI-D-221 5
5 0 ISI-D-222 5
5-8 0
11-1 0
5-9 0
11 - 2 0
5 - 10 0
11 - 3 0
ISI-D-201 2
ISI-D-228 3
ISI-D-202 2
ISI-D-229 3
ISI-D-203 2
12-1 0
ISI-D-204 2
12-2 0
ISI-D-205 2
12-3 0
ISI-D-206 2
12-4 0
ISI-D-207 3
12-5 0
ISI-D-208 3
12-6 0
6-1 0
ISI-D-223 2
6-2 0
ISI-D-224 2
6-3 0
ISI-D-225 2
(]s 6-4 0
13 - 1 0
6-5 0
13 - 2 0
Page 1 of 2 Updated 04/28/97


  -. ....___..._..____.-.__....__.__._.____._.._m                           _ . _      _ . _ . _ . . . _ _ _ . . _ _ _ . _ . _ .
....___..._..____.-.__....__.__._.____._.._m t
t
- Pane No.-
              - Pane No.-                           Rev No. Page No.         Rev.No.
Rev No.
P 13 - 3                             0         17-4             0                                                     :
Page No.
:              ISI-D-226                           3         ISI-D-264         2                                                     ,
Rev.No.
i               ISI-D-227                           3       -
P 13 - 3 0
ISI-D-265         2                                                     '
17-4 0
i               14 - 1                             0         18 - 1           0 14'- 2                             0         18 - 2           0
ISI-D-226 3
!                14 - 3                             0         18 - 3           0 l             . 14-4                               0         18 -4             0 2               14                           0         ISI-D-266         3-
ISI-D-264 2
;              14 - 6                             0         ISI-D-267         3 4
i ISI-D-227 3
14 - 7                             0.       19 - 1           0 0             ' 14-8                               0         19 - 2           0 i               15 - 1                             0         19 -3             0 j-               15 - 2                             0         ISI-D-268         4                                                     *
ISI-D-265 2
]               15 - 3                             0         ISI-D-269         4
i 14 - 1 0
;                15 - 4                             0         20 - 1           0 2
18 - 1 0
15 - f                             0         20 - 2           0                                                     1 i               15 - 6                             0         20 -3             0                                                     ,
14'- 2 0
15 - 7                             0         ISI-D-270         5 15 - 9.                           O         ISI-D-271         2 15 - 8                             0         21 - 1           0 i               15 - 10                           0         21 - 2           0 l               ISI-D-250                           5         21 - 3           0
18 - 2 0
!              ISI-D-251                         '2         ISI-D-277         2 I               ISI-D-252                           2         ISI-D-278         2 ISI-D-253                           2         22 - 1           0 ISI-D-254                           2         22 - 2           0 ISI-D-255                           2         22 - 3           0 ISI-D-256                           2         22 - 4           0 ISI-D-257                           3         22 - 5           0 16 .1                             0         22 - 6           0 16 - 2                             0         ISI-D-272         2 l
14 - 3 0
16 - 3                             0         ISI-D-273         2 16 - 4                             0         ISI-D-274         2 16 - 5                             0         23 - 1           0 16 - 6                             0         23 - 2           0 16 - 7                             0         23 -3             0 ISI-D-258                           2         ISI-D-275         3 ISI-D-259                           2         ISI-D-276         3 ISI-D-260                           2         24 - 1           0 ISI-D-261                           2         24 - 2           0 ISI-D-262                           2         24 - 3           0 ISI-D-263                           2         24 - 4           0 17-1                               0         24 - 5           0 17 - 2                             0 17 - 3                             0 Page 2 of 2                 Updated 04/28/97
18 - 3 0
l
. 14-4 0
18 -4 0
2 14 0 ISI-D-266 3-14 - 6 0
ISI-D-267 3
4 14 - 7 0.
19 - 1 0
0
' 14-8 0
19 - 2 0
i 15 - 1 0
19 -3 0
j-15 - 2 0
ISI-D-268 4
]
15 - 3 0
ISI-D-269 4
15 - 4 0
20 - 1 0
15 - f 0
20 - 2 0
2 1
i 15 - 6 0
20 -3 0
15 - 7 0
ISI-D-270 5
15 - 9.
O ISI-D-271 2
15 - 8 0
21 - 1 0
i 15 - 10 0
21 - 2 0
l ISI-D-250 5
21 - 3 0
ISI-D-251
' 2 ISI-D-277 2
I ISI-D-252 2
ISI-D-278 2
ISI-D-253 2
22 - 1 0
ISI-D-254 2
22 - 2 0
ISI-D-255 2
22 - 3 0
ISI-D-256 2
22 - 4 0
ISI-D-257 3
22 - 5 0
16.1 0
22 - 6 0
16 - 2 0
ISI-D-272 2
l 16 - 3 0
ISI-D-273 2
16 - 4 0
ISI-D-274 2
16 - 5 0
23 - 1 0
16 - 6 0
23 - 2 0
16 - 7 0
23 -3 0
ISI-D-258 2
ISI-D-275 3
ISI-D-259 2
ISI-D-276 3
ISI-D-260 2
24 - 1 0
ISI-D-261 2
24 - 2 0
ISI-D-262 2
24 - 3 0
ISI-D-263 2
24 - 4 0
17-1 0
24 - 5 0
17 - 2 0
17 - 3 0
Page 2 of 2 Updated 04/28/97


1.0     PUMP IST PROGRAM INTRODUCTION 1.1     GENERAL
1.0 PUMP IST PROGRAM INTRODUCTION 1.1 GENERAL
: q
: q
'(v /
'(
This document describes the Pump Inservice Testing (IST) Program for the Vogtle Electric j               Generating Plant (VEGP), Units 1 and 2. Provided below are important dates relative to the IST l               Program.
/
VEGP-1                     VEGP-2 4
This document describes the Pump Inservice Testing (IST) Program for the Vogtle Electric v
Construction Permit:         06-28-74                   06-28-74 j                         Commercial Operation:         05-31-87                   05-20-89 1st 10-Year Interval:         05-31-87 to                 05-20-89 to 05-30-97                   05-30-97*
j Generating Plant (VEGP), Units 1 and 2. Provided below are important dates relative to the IST l
i 2nd 10-Year Interval:         05-31-97 to                 05-31-97* to 05-30-2007                 05-30-2007
Program.
* VEGP-2 was updated at the same time as VEGP-1 for the 2nd 10-Year Interval in order to t
VEGP-1 VEGP-2 4
Construction Permit:
06-28-74 06-28-74 j
Commercial Operation:
05-31-87 05-20-89 1st 10-Year Interval:
05-31-87 to 05-20-89 to 05-30-97 05-30-97*
i 2nd 10-Year Interval:
05-31-97 to 05-31-97* to 05-30-2007 05-30-2007 VEGP-2 was updated at the same time as VEGP-1 for the 2nd 10-Year Interval in order to t
utilize the same Code edition for both units (See Relief Request RR-G-2 which is included in the Valve IST Program document).
utilize the same Code edition for both units (See Relief Request RR-G-2 which is included in the Valve IST Program document).
4 The edition of 10 CFR 50.55a current on May 31,1996, was used to determine the applicable
4 O'
. O'            Code (s) of record for this program update. 10 CFR 50.55a identified the ASME Section XI Code, 1989 Edition, as the applicable Code. The 1989 edition of ASME XI references OM Part 6 (IWP) as being applicable for pump testing. 10 CFR 50.55a(b)(2)(viii) references the OMa-1988 Addenda to the OM-1987 Edition of ANSI /ASME part 6 for pump testing.
The edition of 10 CFR 50.55a current on May 31,1996, was used to determine the applicable Code (s) of record for this program update. 10 CFR 50.55a identified the ASME Section XI Code, 1989 Edition, as the applicable Code. The 1989 edition of ASME XI references OM Part 6 (IWP) as being applicable for pump testing.
10 CFR 50.55a(b)(2)(viii) references the OMa-1988 Addenda to the OM-1987 Edition of ANSI /ASME part 6 for pump testing.
ASME issued the OM Code-1990 Edition which included requirements for pump, valve, relief valve and dynamic restraint inservice testing, and subsequently issued the OMb-1992 Addenda, the OMc-1994 Addenda, the OM-1995 Edition and the OMa-1996 Addenda. Therefore, the below listed Code version is being utilized for pump IST at VEGP as described in Relief Request RR-G-
ASME issued the OM Code-1990 Edition which included requirements for pump, valve, relief valve and dynamic restraint inservice testing, and subsequently issued the OMb-1992 Addenda, the OMc-1994 Addenda, the OM-1995 Edition and the OMa-1996 Addenda. Therefore, the below listed Code version is being utilized for pump IST at VEGP as described in Relief Request RR-G-
,                1. (RR-G-1 is included in the Valve IST Program document.) The NRC approved the use of the 1
: 1. (RR-G-1 is included in the Valve IST Program document.) The NRC approved the use of the 1
ASME OM Code-1990 Edition for pump testing at Plant Vogtle in a letter dated November 27, i               1996.
ASME OM Code-1990 Edition for pump testing at Plant Vogtle in a letter dated November 27, i
!                        ASME OM Code -1990 Edition Subsections ISTA and ISTB This program document includes IST requirements for safety.related ASME Code Class 1,2 and 3 pumps. NRC Generic Letter 89-04 and Supplement 1 (NRC NUREG-1482) were used, to the extent practical, for guidance in the development of this program.
1996.
1.2     EFFECTIVE DATE The Pump IST Program, for the 2nd 10-Year Interval, will become effective on May 31,1997 and will be utilized through May 30,2007 unless federal regulations are revised otherwise.
ASME OM Code -1990 Edition Subsections ISTA and ISTB This program document includes IST requirements for safety.related ASME Code Class 1,2 and 3 pumps. NRC Generic Letter 89-04 and Supplement 1 (NRC NUREG-1482) were used, to the extent practical, for guidance in the development of this program.
1-1                                 Rev.0
1.2 EFFECTIVE DATE The Pump IST Program, for the 2nd 10-Year Interval, will become effective on May 31,1997 and will be utilized through May 30,2007 unless federal regulations are revised otherwise.
1-1 Rev.0


    . -                . . - _    .              _    ~     . _-.                                  .  .
~
1.3     SCOPE This document is a description of the Pump IST Program to be implemented for Units 1 and 2 at i
1.3 SCOPE This document is a description of the Pump IST Program to be implemented for Units 1 and 2 at i
VEGP. This document describes only the IST surveillance testing applicable to safety-related w    ASME Code Class 1,2 and 3 punips included in the program.
VEGP. This document describes only the IST surveillance testing applicable to safety-related ASME Code Class 1,2 and 3 punips included in the program.
A 1.4     SUBSEQUENT PROGRAM REVISIONS It is anticipated that this document will be reviewed again near the end of the 120 month interval and compared to a later NRC approved version of the ASME Code applicable for IST. At that 3      time, the program will be modified, if required, to comply to the extent practical with the later Code edition. Any additional relief requests for impractical requirements will be submitted in 4
w A
accordance with the applicable regulations.
1.4 SUBSEQUENT PROGRAM REVISIONS It is anticipated that this document will be reviewed again near the end of the 120 month interval and compared to a later NRC approved version of the ASME Code applicable for IST. At that time, the program will be modified, if required, to comply to the extent practical with the later 3
1.5     RESPONSIBILITY
Code edition. Any additional relief requests for impractical requirements will be submitted in accordance with the applicable regulations.
{       Southern Nuclear Operating Company, being license holder and agent for Georgia Power Company           !
4 1.5 RESPONSIBILITY
(Owner), bears the overall responsibility for the implementation of the inservice testing activities j       contained in this program per the ASME OM Code - 1990 Edition, Subsection ISTA 1.4.                   l l
{
1.6     RECORDS                                                                                       I i
Southern Nuclear Operating Company, being license holder and agent for Georgia Power Company (Owner), bears the overall responsibility for the implementation of the inservice testing activities j
Records and documentation of information and testing results, which provide the basis for
contained in this program per the ASME OM Code - 1990 Edition, Subsection ISTA 1.4.
~
l l
evaluation and which facilitate comparison with results from previous and subsequent tests, will be maintained and available for the active life of the component or system in accordance with the ASME OM Code - 1990 Edition, Subsection ISTA 3.
1.6 RECORDS i
1.7     METHODS OF TESTING t
Records and documentation of information and testing results, which provide the basis for evaluation and which facilitate comparison with results from previous and subsequent tests, will be
The method of testing applicable to each pump is listed adjacent to the component identification in the Pump IST Program Tables. The ASME OM Code does not stipulate any specific training / certification requirements for personnel involved in pump testing. At Plant Vogtle, all
~
!      pump testing is performed by operations, maintenance or engineering personnel who have been           l l        trained to perform specific testing tasks.
maintained and available for the active life of the component or system in accordance with the ASME OM Code - 1990 Edition, Subsection ISTA 3.
1 1.8     STANDARDS FOR TESTING EVALUATION The acceptance criteria applicable for each pump to be tested have been developed in accordance with the ASME OM Code requirements as modified by any applicable relief requests. Acceptance criteria are not provided in the IST Program document, but are provided in the applicable surveillance testing procedures which are available for review at the plant site.
1.7 METHODS OF TESTING t
O l-2                               Rev.0
The method of testing applicable to each pump is listed adjacent to the component identification in the Pump IST Program Tables.
The ASME OM Code does not stipulate any specific training / certification requirements for personnel involved in pump testing. At Plant Vogtle, all pump testing is performed by operations, maintenance or engineering personnel who have been l
trained to perform specific testing tasks.
1 1.8 STANDARDS FOR TESTING EVALUATION The acceptance criteria applicable for each pump to be tested have been developed in accordance with the ASME OM Code requirements as modified by any applicable relief requests. Acceptance criteria are not provided in the IST Program document, but are provided in the applicable surveillance testing procedures which are available for review at the plant site.
O l-2 Rev.0


ABBREVIATIONS LIST Abbreviation     Definition Acc               Accuracy AFW               Auxiliary Feedwater
ABBREVIATIONS LIST Abbreviation Definition Acc Accuracy AFW Auxiliary Feedwater
  ' Amp.             Amplitude ASME American Society of Mechanical Engineers atm .             Atmospheric Aux               Auxiliary Bldg             Building CC ASME Code Class CCW Component Cooling Water Coord.           Coordinate CS Containment Spray CVCS Chemical Volume & Control System AP               Pump DifferentialPressure APr Reference DifferentialPressure Differ.           Differential ECCS Eme gency Code Cooling System ESF Eagmeered Safety Feature F
' Amp.
Fahrenheit FI FlowrateIndicator ft                 Feet Freq.             Frequency GPC               Georgia Power Company gpm Gallons Per Minute Hz               Hertz I.D.             Identification in/s Inches Per Second IST               Inservice Testing kW               Kilowatt LOCA Loss OfCoolant Accident LI                 LevelIndicator NA                 Not Applicable N                 Speed No.               Number NPSH Net Positive Suction Head NSCW               Nuclear Service Cooling Water OM                 ASME OM Code PC Vogtle Plant Project Class P&ID               Piping & Instrumentation Diagram Pi                 Pump Inlet Pressure PI                 Pressure Indicator Po                 Pump Outlet Pressure psig               Pounds Per Square Inch 21                               Rev.O i
Amplitude ASME American Society of Mechanical Engineers atm.
Atmospheric Aux Auxiliary Bldg Building CC ASME Code Class CCW Component Cooling Water Coord.
Coordinate CS Containment Spray CVCS Chemical Volume & Control System AP Pump DifferentialPressure APr Reference DifferentialPressure Differ.
Differential ECCS Eme gency Code Cooling System ESF Eagmeered Safety Feature F
Fahrenheit FI FlowrateIndicator ft Feet Freq.
Frequency GPC Georgia Power Company gpm Gallons Per Minute Hz Hertz I.D.
Identification in/s Inches Per Second IST Inservice Testing kW Kilowatt LOCA Loss OfCoolant Accident LI LevelIndicator NA Not Applicable N
Speed No.
Number NPSH Net Positive Suction Head NSCW Nuclear Service Cooling Water OM ASME OM Code PC Vogtle Plant Project Class P&ID Piping & Instrumentation Diagram Pi Pump Inlet Pressure PI Pressure Indicator Po Pump Outlet Pressure psig Pounds Per Square Inch 21 Rev.O i


_ __ _ ... _. _      __.._....._.. _.._ _ _ _ _ ~ _.... .... _ . _ .. _ _ _ . _ _ . _.-. _ _ _ _ . .__ _ __ _ . _ ._ _ ._... _ ..       -
__.._....._.. _.._ _ _ _ _ ~ _........ _. _.. _ _ _. _ _. _.-. _ _ _ _..__ _ __ _. _._ _._... _..
4 l
4 1
1 Abbreviations (cont.)
Abbreviations (cont.)
i a
i a
Abbreviation                                                                   Definition Q                                                                     - Pump Flowrate Qtr.                                                                         Quarterly                                   ,
Abbreviation Definition Q
Qr                                                                                                                       !
- Pump Flowrate Qtr.
Reference Flowrate RCS                                                                                                                       !
Quarterly Qr Reference Flowrate RCS Reactor Coolant System l
Reactor Coolant System l                 Ref.                                                                         Reference                                   l Req.~                                                                         Required                                     .
Ref.
RHR                                                                                                                       :
Reference Req.~
'                                                                                                ResidualHeat Removal                       j rpm Revolutions PerMinute
Required RHR ResidualHeat Removal j
!                  RR                                                                            ReliefRequest i
rpm Revolutions PerMinute RR i
i                  SI                                                                           SafetyInjection j-                 SI                                                                           Speed Indicator
ReliefRequest i
!                  SNC Southern Nuclear Operating Company V                                                                             Vibration i                 VEGP                                                                         Vogtle Electric Generating.'lant i                 Vib.                                                                         Vibration Vr                                                                           Reference Vibration Amplitude I
SI SafetyInjection j-SI Speed Indicator SNC Southern Nuclear Operating Company V
Vibration i
VEGP Vogtle Electric Generating.'lant i
Vib.
Vibration Vr Reference Vibration Amplitude I
t i
t i
I l
I liO l
iO l
4 i
4 i
1 i
1 i
O 2-2                 Rev.0
O 2-2 Rev.0


INTRODUCTIGN A. Regulatory Position r''N U                                     ~
INTRODUCTIGN A.
This document defines the testing requirements for the pumps incicded for inservice testing (IST) at Southern Nuclear Operating Company's (SNC) Vogtle Electric Generating Plant (VEGP) Unit I and 2.         This Pump IST Program was developed to comply with the         i provisions of 10 CFR 50.55a. The Code of record applicable for this program is the ASME OM Code - 1990 Edition. NRC Generic Letter 89-04 and its Supplement 1 (NUREG-1482) were used for guidance, to the extent practical, in the development of this program document.
Regulatory Position r''N U
B. Ssage In accordance with 10 CFR 50.55a and NRC Regulatory Guide 1.26 (water, steam and radioactive waste containing systems), ASME Code Class 1,2 and 3 safety-related pumps which perform a function required in; 1) shutting the reactor down to the cold shutdown condition,2) maintaining the cold shutdown condition,3) or mitigating the consequences of an accident, and are provided with an emergency power source, are included in this program document for inservice testing.
This document defines the testing requirements for the pumps incicded for inservice testing
It was recognized that 10 CFR 50, Appendix A, General Design Criteria 1, and Appendix B, Criterion XI, intended that all pumps necessary for safe operation of the plant be tested to demonstrate that they will perform satisfactorily in service. The subject testing is to be performed to a level commensurate with the safety significance of the pump. For those non-
~
(IST) at Southern Nuclear Operating Company's (SNC) Vogtle Electric Generating Plant (VEGP) Unit I and 2.
This Pump IST Program was developed to comply with the i
provisions of 10 CFR 50.55a. The Code of record applicable for this program is the ASME OM Code - 1990 Edition. NRC Generic Letter 89-04 and its Supplement 1 (NUREG-1482) were used for guidance, to the extent practical, in the development of this program document.
B.
Ssage In accordance with 10 CFR 50.55a and NRC Regulatory Guide 1.26 (water, steam and radioactive waste containing systems), ASME Code Class 1,2 and 3 safety-related pumps which perform a function required in; 1) shutting the reactor down to the cold shutdown condition,2) maintaining the cold shutdown condition,3) or mitigating the consequences of an accident, and are provided with an emergency power source, are included in this program document for inservice testing.
It was recognized that 10 CFR 50, Appendix A, General Design Criteria 1, and Appendix B, Criterion XI, intended that all pumps necessary for safe operation of the plant be tested to demonstrate that they will perform satisfactorily in service. The subject testing is to be
[]
[]
L ASME Code Class 1,2 and 3 pumps, this testing is performed in accordance with the plant technical specifications and/or other plant testing programs and is not included in this program document.
performed to a level commensurate with the safety significance of the pump. For those non-L ASME Code Class 1,2 and 3 pumps, this testing is performed in accordance with the plant technical specifications and/or other plant testing programs and is not included in this program document.
The determination as to whether a pump should be included in this testing program was performed by review and evaluation of the Updated Final Safety Analysis Reports (UFSAR) and other design and licensing documents. These documents were reviewed to determine 1
The determination as to whether a pump should be included in this testing program was performed by review and evaluation of the Updated Final Safety Analysis Reports (UFSAR) and other design and licensing documents. These documents were reviewed to determine 1
which pumps are required to respond to the design basis accident scenarios and provide a     ;
which pumps are required to respond to the design basis accident scenarios and provide a function required to shutdown the reactor, maintain the shutdown condition, or mitigate the consequences of the accident.
function required to shutdown the reactor, maintain the shutdown condition, or mitigate the consequences of the accident.
C.
C. Testine Reauirements A description of the ASME OM Code testing requirements applicable to pumps is provided in each section. The ASME OM Code-1990 Edition should be used in conjunction with this         !
Testine Reauirements A description of the ASME OM Code testing requirements applicable to pumps is provided in each section. The ASME OM Code-1990 Edition should be used in conjunction with this description to ensure a complete identification of the testing requirements. Subsection ISTB l
description to ensure a complete identification of the testing requirements. Subsection ISTB l' of the ASME OM Code is applicable for pump inservice testing and the applicable ISTB paragraph is listed in parenthesis for cross reference.
of the ASME OM Code is applicable for pump inservice testing and the applicable ISTB paragraph is listed in parenthesis for cross reference.
: 1. Definitions (ISTB 1.3)                                                                 l
1.
{
Definitions (ISTB 1.3) l
v               The below listed definitions are provided for easy reference as they are applicable to VEGP and are used in subsequent sections of this introduction.
{v The below listed definitions are provided for easy reference as they are applicable to VEGP and are used in subsequent sections of this introduction.
0 3-1                               Rev.0
0 3-1 Rev.0


3 i
inservice rest - a test to determine the operational readmess of a pump 3
inservice rest - a test to determine the operational readmess of a pump
i instrument accuracy - the allowable inaccuracy of an instrument loop based on the l
:.                  instrument accuracy - the allowable inaccuracy of an instrument loop based on the     .
square root of the sum of the square of the inaccuracies of each instrument or
l                    square root of the sum of the square of the inaccuracies of each instrument or
[
[                     component in the loop-instrument loop - two or more instruments or components working together to provide i
component in the loop-instrument loop - two or more instruments or components working together to provide i
a single output (e.g., a vibration probe and its associated signal conditioning and
a single output (e.g., a vibration probe and its associated signal conditioning and readout devices) operationalreadiness - the ability of a pump to perform its intended function preservice testperiod - the period of time after completion of construction activities j
;                    readout devices) operationalreadiness - the ability of a pump to perform its intended function
!                  preservice testperiod - the period of time after completion of construction activities j
related to the pump and before first electrical generation by nuclear heat, in which component and system testing take place 1
related to the pump and before first electrical generation by nuclear heat, in which component and system testing take place 1
j                   pump - a mechanical device used to move liquid                                           l J
j pump - a mechanical device used to move liquid J
reference values - one or more values of test parameters measured or determined when the equipment is know to be operating acceptably l
reference values - one or more values of test parameters measured or determined when the equipment is know to be operating acceptably i
i routine servicing - the performance of planned, preventative maintenance (e.g.,           ;
routine servicing - the performance of planned, preventative maintenance (e.g.,
replacing or adjusting valves in reciprocating pumps, changing oil, flushing the cooling i
replacing or adjusting valves in reciprocating pumps, changing oil, flushing the cooling i
system, adjusting packing, adding p*Wg rings or mechanical seal maintenance or           :
system, adjusting packing, adding p*Wg rings or mechanical seal maintenance or replacement) l system resistance - the hydraulic resistance to flow in a system 2.
replacement)                                                                             l system resistance - the hydraulic resistance to flow in a system 2.
Reference Information (ISTB 2)
Reference Information (ISTB 2)
The hydraulic and mechanical condition of a pump relative to a previous condition can be determined by attempting to duplicate by test a set of reference values. Deviations detected are symptoms of changes and, depending upon the degree of deviation, indicate need for further tests or corrective action.
The hydraulic and mechanical condition of a pump relative to a previous condition can be determined by attempting to duplicate by test a set of reference values. Deviations detected are symptoms of changes and, depending upon the degree of deviation, indicate need for further tests or corrective action.
: 3. Owner's Responsibility (ISTB 3.1)
3.
Each pump to be tested in accordance with this program shall be identified by the         ;
Owner's Responsibility (ISTB 3.1)
Owner and listed in the plant records.                                                     '
Each pump to be tested in accordance with this program shall be identified by the Owner and listed in the plant records.
: 4. Testing Requirements (ISTB 4) 1 A. Preservice Testine (ISTB 4.1) j Each pump shall be tested during the preservice test period. These tests shall be         !
4.
conducted under conditions as near as practical to those expected during subsequent O             inservice testing. Only one preservice test is required for each pump, except when a pump is repaired or replaced (see C.4.D).
Testing Requirements (ISTB 4) 1 A. Preservice Testine (ISTB 4.1) j Each pump shall be tested during the preservice test period. These tests shall be conducted under conditions as near as practical to those expected during subsequent O
j I
inservice testing. Only one preservice test is required for each pump, except when a j
3-2         Rev.O             I l
pump is repaired or replaced (see C.4.D).
l l
I 3-2 Rev.O


B. Inservice Testina (ISTB 4.2)
B. Inservice Testina (ISTB 4.2)
Inservice testing shall commence when the pump is required to be operable (see C.5.C).
Inservice testing shall commence when the pump is required to be operable (see C.5.C).
t l3 V   C. Reference Values (ISTB 4.3)
l3 t
V C. Reference Values (ISTB 4.3)
Initial reference values shall be determined from the results of the preservice test or from the results of the first inservice test.
Initial reference values shall be determined from the results of the preservice test or from the results of the first inservice test.
Reference values shall be established at points of operation readily duplicated during subsequent testing.
Reference values shall be established at points of operation readily duplicated during subsequent testing.
Line 190: Line 401:
If the particular parameter being measured or determined can be significantly influenced by other related conditions, then these conditions shall be analyzed.
If the particular parameter being measured or determined can be significantly influenced by other related conditions, then these conditions shall be analyzed.
D. Effect of Pump Reolacement. Reoair. and Maintenance on Reference Values (ISTB 4.4)
D. Effect of Pump Reolacement. Reoair. and Maintenance on Reference Values (ISTB 4.4)
When a reference value or set of reference values may have been affected by repair,           ;
When a reference value or set of reference values may have been affected by repair,
  ],s replacement, or routine servicing of a pump, a new reference value or set of reference values shall be established in accordance with C.4.C above (ISTB 4.3), or the previous         .
],s replacement, or routine servicing of a pump, a new reference value or set of reference values shall be established in accordance with C.4.C above (ISTB 4.3), or the previous value(s) reconfirmed by an inservice test run before declaring the pump operable.
l value(s) reconfirmed by an inservice test run before declaring the pump operable.
Deviations between the previouc and new reference value(s) shall be evaluated, and verification that the new reference value(s) represent acceptable pump operation shall be placed in the record of tests.
l Deviations between the previouc and new reference value(s) shall be evaluated, and             l verification that the new reference value(s) represent acceptable pump operation shall be placed in the record of tests.
E. Establishment of Additional Set of Reference Values (ISTB a 5)
E. Establishment of Additional Set of Reference Values (ISTB a 5)                             i If necessary or desirable, for some reason other than stated in C.4.D above, to establish an additional set of reference values, an inservice test shall be run at the conditions of an existing set ofieference values and the results analyzed. If operation is acceptable per C.5.B (ISTB 6.2), then a second test run at new reference conditions shall follow as soon as practical. The results of this test shall establish the additional set of reference   I values.
If necessary or desirable, for some reason other than stated in C.4.D above, to establish an additional set of reference values, an inservice test shall be run at the conditions of an existing set ofieference values and the results analyzed. If operation is acceptable per C.5.B (ISTB 6.2), then a second test run at new reference conditions shall follow as soon as practical. The results of this test shall establish the additional set of reference I
Whenever new reference values are established, the reason for doing so shall be l       documented in the record of tests.
values.
fh l
Whenever new reference values are established, the reason for doing so shall be l
I 0
documented in the record of tests.
'                                            3-3                                   Rev.O
fh 0
l I
3-3 Rev.O


      . . - - . -. -- - - . - . ~                         - - . . -            . - - . . . . . . - . . - - . . - . . - . _ . - . . - - . . . - -
.. - -. -. -- - -. -. ~
f' F. Instrumentation (ISTB 4.6)                                                                                         '
f' F. Instrumentation (ISTB 4.6)
Instrument accuracy shall be within the limits of the below table (Table ISTB 4.6.1-1).
Instrument accuracy shall be within the limits of the below table (Table ISTB 4.6.1-1).
Station instruments meeting these requirements are acceptable.                                                       j l                                  ACCEPTABLE INSTRUMENT ACCURACY (Table ISTB 4.6.1-1) j                                                                 Percent Quantity                       [ Note (1)]
Station instruments meeting these requirements are acceptable.
Pressure                       i2%
j ACCEPTABLE INSTRUMENT ACCURACY (Table ISTB 4.6.1-1) l j
l                                 Flow Rate '                   i2%                                                                             ~
Percent Quantity
1                                 Speed i                                                                i2%
[ Note (1)]
j                                 Vibration                     iS%                                                                                     !
Pressure i2%
DifferentialPressure           i2%
l Flow Rate '
i2%
~
1 Speed i2%
i j
Vibration iS%
DifferentialPressure i2%
i NOTE:
Y (1) Percent of full scale for individual analog instruments, percent of total loop accuracy for a combination ofinstruments, or over the calibrated range for digital j
instruments.
i
i
!                                  NOTE:                                                                                                                  Y (1) Percent of full scale for individual analog instruments, percent of total loop accuracy for a combination ofinstruments, or over the calibrated range for digital                                          ;
{
j                                      instruments.                                                                                                        '
The full-scale range of analog instruments shall not be greater than three times the i
i
reference value.
{                                  The full-scale range of analog instruments shall not be greater than three times the i                                 reference value.
Digital instruments shall be selected such that the reference value does not exceed 70%
Digital instruments shall be selected such that the reference value does not exceed 70%
;                                of the calibrated range of the instrument.                                                                                 j I
of the calibrated range of the instrument.
Vibration instruments are excluded from the range requirements stated above. The                                       '
j Vibration instruments are excluded from the range requirements stated above. The i
i 1
frequency response range of vibration measuring transducers and their readout system 1
frequency response range of vibration measuring transducers and their readout system shall be from one-third minimum pump operating speed to at least 1000 Hz.
shall be from one-third minimum pump operating speed to at least 1000 Hz.
i                                 The Owner shall be responsible for establishing the location of instruments used for
i The Owner shall be responsible for establishing the location of instruments used for
}                                                                                                                                                           {
{
inservice testing. The location shall be appropriate for the parameter being measured                                     !
}
i and the same location shall be used for subsequent tests. Instruments that are position-
inservice testing. The location shall be appropriate for the parameter being measured and the same location shall be used for subsequent tests. Instruments that are position-i
{                                                                                                                                                           !
{
sensitive shall be either permanently mounted, or provisions shall be made to duplicate their position during each test.                                                                                           l
sensitive shall be either permanently mounted, or provisions shall be made to duplicate their position during each test.
;                                                                                                                                                            l j
1 j
1 i
Instruments and instrument loops shall be cahbrated in accordance with the Owner's i
Instruments and instrument loops shall be cahbrated in accordance with the Owner's quality assurance program New or repaired instruments shall be calibrated before test l                               use.
quality assurance program New or repaired instruments shall be calibrated before test l
use.
1
1
[                               G. Pressure Memenrements (ISTB 4.6.2)                                                                                       l l'                                                                                                                                                           i i                                Differential pressure across a pump may be determined using a differential pressure gage i                               or a differential pressure transmitter that provides direct measurement of pressure
[
;                              difference, or the difference between pump discharge pressure and pump inlet pressure j .
G. Pressure Memenrements (ISTB 4.6.2) l' i
Differential pressure across a pump may be determined using a differential pressure gage i
or a differential pressure transmitter that provides direct measurement of pressure difference, or the difference between pump discharge pressure and pump inlet pressure j
shall be used.
shall be used.
1 1                                                                         3-4                                                             Rev.0 1
1 1
i
3-4 Rev.0 1
          -, - - . .                                , ~ -         --                                                                              ,--
i s
, ~ -
-m m-


4 H. Rotational Speed Man =nremente GSTB 4.6.3)                                                         !
4 H. Rotational Speed Man =nremente GSTB 4.6.3) a i
a i
Rotational speed measurements of variable speed pumps shall be measured by a method I
I Rotational speed measurements of variable speed pumps shall be measured by a method l that meets the instrument accuracy requirements of the above instrument accuracy table c
that meets the instrument accuracy requirements of the above instrument accuracy table (C.4.F).
(C.4.F).
c
)                         I. Vibration Man = e...=a GSTB 4.6.4) j p
)
On centrifugal pumps, vibration measurements shall be taken in a plane approximately                 i perpendicular to the rotatmg shaft in two orthogonal directions on each accessible                 D j
I. Vibration Man = e...=a GSTB 4.6.4) j p
pump-bearing housing. Measurement shall also be taken in the axial direction on each                 "
On centrifugal pumps, vibration measurements shall be taken in a plane approximately perpendicular to the rotatmg shaft in two orthogonal directions on each accessible D
;                        accessible pump thrust bearing housing.
i j
pump-bearing housing. Measurement shall also be taken in the axial direction on each accessible pump thrust bearing housing.
t l
t l
;                        On vertical line shaft pumps, measurements shall be taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
On vertical line shaft pumps, measurements shall be taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
If portable vibration instruments are used, the ' measurement points shall be clearly identified on the pump to permit repeatability in both location and plane.
If portable vibration instruments are used, the ' measurement points shall be clearly identified on the pump to permit repeatability in both location and plane.
J. Flow Rate Ma==nremanta GSTB 4.6.5)
J. Flow Rate Ma==nremanta GSTB 4.6.5)
Flow rate shall be measured using a rate or quantity meter installed in the pump test                 l circuit. If the meter does not indicate flow rate directly, the record of tests shall include the method used to reduce the data.
Flow rate shall be measured using a rate or quantity meter installed in the pump test l
j
circuit. If the meter does not indicate flow rate directly, the record of tests shall include the method used to reduce the data.
: 5.       Testing Methods (ISTB 5)
j 5.
Testing Methods (ISTB 5)
A. Frequency ofInservice Tests GSTB 5.1)
A. Frequency ofInservice Tests GSTB 5.1)
An inservice test shall be performed on each pump nominally every 3 months except for .
An inservice test shall be performed on each pump nominally every 3 months except for.
pumps that are declared inoperable or are not required to be operable.
pumps that are declared inoperable or are not required to be operable.
B. Test Procabre GSTB 5.2)
B. Test Procabre GSTB 5.2)
An inservice tests shall be conducted with the pump operating at specified test reference conditions. The test parameters listed in the below tables shall be determined and recorded.
An inservice tests shall be conducted with the pump operating at specified test reference conditions. The test parameters listed in the below tables shall be determined and recorded.
t i
t i
O 3-5                                                 Rev.0
O 3-5 Rev.0


4 i                                                                          INSERVICE TEST PARAMETERS (Tchle ISTB 5.2-1)
4 INSERVICE TEST PARAMETERS (Tchle ISTB 5.2-1) i Quantity Remarks Speed, N Ifvariable speed pump
Quantity                                     Remarks
~
                                                                              ~
i DifferentialPressure, AP
:                                                    Speed, N i                                                                                                Ifvariable speed pump DifferentialPressure, AP                 ' Centrifugal pumps, including vertical line shaft I
' Centrifugal pumps, including vertical line shaft I
Pumps i
Pumps i
l                                                   Discharge Pressure, P                       Positive displacement pumps
l Discharge Pressure, P Positive displacement pumps Flow Rate, Q All pumps i
!                                                    Flow Rate, Q                               All pumps i
i Vibration i
i                                                     Vibration i
Displacement, Vd Peak-to-Peak Velocity, VV Peak The pump shall be operated at nominal motor speed for a constant speed driver or at a speed adjusted to the reference point for variable speed drivers.
Displacement, Vd                   Peak-to-Peak Velocity, VV                       Peak The pump shall be operated at nominal motor speed for a constant speed driver or at a speed adjusted to the reference point for variable speed drivers.
The resistance of the system shall be adjusted until the flow rate equals the reference value. The differential pressure shall then be determined and compared to the reference value. Alternately, the flow rate shall be varied until the differential pressure equals the O
The resistance of the system shall be adjusted until the flow rate equals the reference value. The differential pressure shall then be determined and compared to the reference value. Alternately, the flow rate shall be varied until the differential pressure equals the O                                             reference value and the flow rate determined and compared to the reference flow rate value.
reference value and the flow rate determined and compared to the reference flow rate value.
If system resistance cannot be varied, flow rate and pressure shall be determined and compared to their respective reference values.
If system resistance cannot be varied, flow rate and pressure shall be determined and compared to their respective reference values.
Pressure, flow rate, and sihration shall be determined and compared with the corresponding reference values. All deviations from the reference values shall be compared with the acceptance criteria listed below and corrective action shall be taken as specified in Section C.6.
Pressure, flow rate, and sihration shall be determined and compared with the corresponding reference values. All deviations from the reference values shall be compared with the acceptance criteria listed below and corrective action shall be taken as specified in Section C.6.
Vibration measurements shall be broad band (unfiltered). Velocity measurements shall be peak and displacement amplitudes shall be peak-to-peak respectfully.
Vibration measurements shall be broad band (unfiltered). Velocity measurements shall be peak and displacement amplitudes shall be peak-to-peak respectfully.
O 3-6                                         Rev.0
O 3-6 Rev.0


VIBRATION ACCEPTANCE CRITERIA (Table ISTB 5.2-2a)
VIBRATION ACCEPTANCE CRITERIA (Table ISTB 5.2-2a)
Pump                 Pump             Test             Acceptable                 Alert             Required
Pump Pump Test Acceptable Alert Required
  /Q     Type                 Speed         Parameter               Range                   Range V                                                                                                        Action Range Centrifugal &       <600 rpm         Vd or VV         52.5Vr             >2.5Vr to 6Vr or           >6Vr or Venical Line
/Q Type Speed Parameter Range Range Action Range V
                                                                                    >10.5 to 22 mils           >22 mils i       Shaft (Note 2)                                                                                                                   l 4
Centrifugal &
Centrifugal &         2 600 rpm       Vvor Vd           s2.5Vr             >2.5Vr to 6Vr or         >6Vr or                     I VerticalLinc
<600 rpm Vd or VV 52.5Vr
                                                                                    >0.325 to 0.7 in/sec       >0.7 in/sec l       Shaft (Note 2)
>2.5Vr to 6Vr or
Reciprocating                         Vd or Vr         s2.5Vr             >2.5Vr to 6Vr             >6Vr NOTES:
>6Vr or Venical Line
>10.5 to 22 mils
>22 mils i
Shaft (Note 2) 4 Centrifugal &
2 600 rpm Vvor Vd s2.5Vr
>2.5Vr to 6Vr or
>6Vr or I
VerticalLinc
>0.325 to 0.7 in/sec
>0.7 in/sec l
Shaft (Note 2)
Reciprocating Vd or Vr s2.5Vr
>2.5Vr to 6Vr
>6Vr NOTES:
(1) Vr is reference vibration value in selected units.
(1) Vr is reference vibration value in selected units.
(2) Refer to OM Code Figure ISTB 5.2 1 to establish di=!=~nt limits for pumps with speeds 2 600 rpm or velocity limits for pumps with speeds s 600 rpm.
(2) Refer to OM Code Figure ISTB 5.2 1 to establish di=!=~nt limits for pumps with speeds 2 600 rpm or velocity limits for pumps with speeds s 600 rpm.
l HYDRAULIC ACCEPTANCE CRITERIA (Table ISTB 5.2-2b)
l HYDRAULIC ACCEPTANCE CRITERIA (Table ISTB 5.2-2b)
'                                              Acceptable                                             Required Action Range Test Parameter               Range                       Aled Range a
Acceptable Required Action Range Test Parameter Range Aled Range Low High I
Low                   High         I I                                                                                                                                         l
a I
('T   P (Positive Displacement Pumps)         0.93 to 1.10Pr           0.90 to <0.93Pr           <0.90Pr U                                                                                                                          >1.10Pr AP (VerticalLine Shaft Pumps)           0.95 to 1.10APr           0.93 to <0.95APr           <0.93APr               >l.10APr Q(Positive Displacement and             0.95 to 1.10Qr 0.93 to <0.95Qr           <0.93Qr               >1.10Qr VerticalLine Shaft Pumps)
('T P (Positive Displacement Pumps) 0.93 to 1.10Pr 0.90 to <0.93Pr
AP (Centrifugal Pumps)                   0.90 to 1.10APr               none
<0.90Pr
                                                                                                      <0.90APr             >1.10APr
>1.10Pr U
,        Q (Centrifugal Pumps)                   0.90 to 1.10Qr               none                   <0.90Qr               >1.10Qr C. Pumos In Systems Out of Service GSTB 5.4)
AP (VerticalLine Shaft Pumps) 0.95 to 1.10APr 0.93 to <0.95APr
<0.93APr
>l.10APr Q(Positive Displacement and 0.95 to 1.10Qr 0.93 to <0.95Qr
<0.93Qr
>1.10Qr VerticalLine Shaft Pumps)
AP (Centrifugal Pumps) 0.90 to 1.10APr none
<0.90APr
>1.10APr Q (Centrifugal Pumps) 0.90 to 1.10Qr none
<0.90Qr
>1.10Qr C. Pumos In Systems Out of Service GSTB 5.4)
For a pump in a system declared inoperable or not required to be operable, the test schedule need not be followed. However, within 3 months before the system is placed in an operable status, the pump shall be tested. Pumps that can only be tested during plant operation shall be tested within I week following startup.
For a pump in a system declared inoperable or not required to be operable, the test schedule need not be followed. However, within 3 months before the system is placed in an operable status, the pump shall be tested. Pumps that can only be tested during plant operation shall be tested within I week following startup.
i
i
(               D. Duration ofTests GSTB 5.6)
(
D. Duration ofTests GSTB 5.6)
After pump conditions are as stable as the system permits, each pump shall be run for at least 1
After pump conditions are as stable as the system permits, each pump shall be run for at least 1
2 minutes prior to measuring any ofthe required test parameters.
2 minutes prior to measuring any ofthe required test parameters.
!O
!O 3-7 Rev.O t
,                                                                3-7                                           Rev.O t


,-    . ..- .. . - - . -                            ..~- - . - - _ - .                             - -      . . . . ~ . . - .. ..
..~- -. - - _ -.
;              6.         A::alysis czd Ev:.1=ti:2 (ISTB 6) 4 A.- Acceptance Criteria GSTB 6.1)
.... ~.. -..
J i U b
6.
If the measured test parameter values fall within the alert range of the applicable table (see -
A::alysis czd Ev:.1=ti:2 (ISTB 6)
[                         C.S.above), the frequency of testing shall be doubled until the cause of the deviation is determined and the condition is corrected.                                                             ,
A.- Acceptance Criteria GSTB 6.1) 4 b Ji U If the measured test parameter values fall within the alert range of the applicable table (see -
j If the measured test parameter values fall within the required action range of the applicable table (see C.5 above), the pump shall be declared inoperable until either the cause of the 2
[
deviation has been determined and the condition corrected. (See ReliefRequest RR-P-2)
C.S.above), the frequency of testing shall be doubled until the cause of the deviation is determined and the condition is corrected.
If the measured test parameter values fall within the required action range of the applicable j
table (see C.5 above), the pump shall be declared inoperable until either the cause of the deviation has been determined and the condition corrected. (See ReliefRequest RR-P-2) 2
)
)
When a test shows measured parameter values that fall outside the acceptable rarges that have resulted from an identified system error (e.g. improper system lineup, inaccurate                 ;
When a test shows measured parameter values that fall outside the acceptable rarges that have resulted from an identified system error (e.g. improper system lineup, inaccurate instruments) the test shall be rerun after correcting the error.
instruments) the test shall be rerun after correcting the error.
B. Time Allowed for Analysis ofTests GSTB 6.2)
B. Time Allowed for Analysis ofTests GSTB 6.2)
?
?
l All test data shall be analyzed within 96 hours after completion of test.
l All test data shall be analyzed within 96 hours after completion of test.
i         - 7.           Records and Reports (ISTB 7) a j                         A. Pumo Records GSTB 7.1) fj                       The Owner shall maintain a record, for each pump included in the program, that includes the j'                       followinginformation:                                                                                     ,
i
)                                                                                                                                 1
- 7.
{                                                                                                                                 I (a) the manufacturer and the manufacturer's model and serial number or other identification !
Records and Reports (ISTB 7) a j
i                              number, j
A. Pumo Records GSTB 7.1) fj The Owner shall maintain a record, for each pump included in the program, that includes the j'
(b) a copy or summary of the manufacturer's acceptance test report if available; and
followinginformation:
!                        (c) a copy of the pump manufacturer's operating limits.
)
1
{
I (a) the manufacturer and the manufacturer's model and serial number or other identification i
: number, j
(b) a copy or summary of the manufacturer's acceptance test report if available; and (c) a copy of the pump manufacturer's operating limits.
B. Inservice Test Plans GSTB 7.2) i The Owner shall maintain a record of test plans and procedures that shall include the following:
B. Inservice Test Plans GSTB 7.2) i The Owner shall maintain a record of test plans and procedures that shall include the following:
i (a) the hydraulic circuit to be used; (b) the location and type of measurements for the required test parameters;                               ;
i (a) the hydraulic circuit to be used; (b) the location and type of measurements for the required test parameters; (c) the reference values; and 1
(c) the reference values; and 1
(d) the method of determining test parameter values that are not directly measured by instrumentation.
(d) the method of determining test parameter values that are not directly measured by instrumentation.
This Pump IST Program document in conjunction with the pump surveillance test procedures satisfy the above requirement.
This Pump IST Program document in conjunction with the pump surveillance test procedures satisfy the above requirement.
O 3-8                             Rev.0
O 3-8 Rev.0


C. Record ofTests USTB 7.3)
C. Record ofTests USTB 7.3)
The Owner shall maintain a record of each test that shall include the following:
The Owner shall maintain a record of each test that shall include the following:
                                  ~
. (s) pump identification;.
  . (s) pump identification; .
~
(b) date of test;
(b) date of test;
  . (c) reason for test (e.g. post-maintenance, routine inservice test, or establishing new reference values);
. (c) reason for test (e.g. post-maintenance, routine inservice test, or establishing new reference values);
:(d) values ofmeasured parameters; (e) identification ofinstruments used; (f) comparisons with allowable ranges of test values and analysis of deviations; (g) requirements for corrective action; (h) evaluation andjustification for changes to reference values; and (I) signature of the person (s) responsible for conducting and analyzing the test data.
:(d) values ofmeasured parameters; (e) identification ofinstruments used; (f) comparisons with allowable ranges of test values and analysis of deviations; (g) requirements for corrective action; (h) evaluation andjustification for changes to reference values; and (I) signature of the person (s) responsible for conducting and analyzing the test data.
This Pump IST Program document in conjunction with the pump surveillance test procedures satisfy the above requirement.
This Pump IST Program document in conjunction with the pump surveillance test procedures satisfy the above requirement.
D. Record ofCorrective Action GSTB 7.4)
D. Record ofCorrective Action GSTB 7.4)
The Owner shall maintain records of corrective action that shall include a summary of the corrections made, the subsequent inservice tests and confirmation of operational adequacy, and the signature of the individual (s) responsible for corrective action and verification of results.
The Owner shall maintain records of corrective action that shall include a summary of the corrections made, the subsequent inservice tests and confirmation of operational adequacy, and the signature of the individual (s) responsible for corrective action and verification of results.
O                                                                                                       '
O O
O 3-9                               Rev.0
3-9 Rev.0


                                                                                                                                                                                          . - . _ . ~ - . . . - - .. . - - .                                                                   - -
. -. _. ~ -... - -... - -.
O                                                                                           .
O O
O VEGP-1 PUMP TEST TABLE Nuclear Service Cooling Water - System 1202 i
VEGP-1 PUMP TEST TABLE Nuclear Service Cooling Water - System 1202 Measured Parmarters & Frm i
Measured Parmarters & Frm LD. Number         CC/PC         PalD-Sheet No.                     _CM Description                                                               h                           E           R               Y           E                                     NW Gulal                         (a:D       isa!al theerl                 smal                                                                 ,
LD. Number CC/PC PalD-Sheet No.
I l-1202-P4-001     3D13           IX4D1133-1                         C-8 NSCW Pump                                                                 QTR                         QTR         QTR             QTR         NA                                   RR-P-2 1-1202-P4-002       3813           IX4DB133-2                       C-5   NSCW Pump                                                                 QIR                                                                     NA QTR         QTR             QIR                                               RR-P-2                         +
_CM Description h
i 1-1202-P4-003       3813         IX4DB133-1                         C-5 NSCW Pump                                                                                             QTR                                         NA QTR                                       QTR             QIR                                             RR-P-2 1-1202-P4-004       3/313         IX4DB133-2                         C-5 NSCW Pump                                                                 QIR                         QTR' QTR                       QTR         NA                                 RR-P-2 1-1202-P4-005       3D13         IX4DB133-1                         C-7 NSCW Pump                                                                 QTR                       QTR           QIR             QTR         NA                               RR-P-2 1-1202-P4-006     3D13         IX4DB133-2                         C-7 NSCW Pump                                                                 QIR                       QTR           QTR             QIR           NA                               RR-P-2 1-1202-P4-007       3D13         IX4DB133-1                         C4   NSCW Transfer Pump                                                       QTR                       QTR           QTR             QTR           NA                             RR-P-2 1-1202-P4-008       3D13         IX4DB133-2                         C-6 NSCWTransfer Pump                                                         QIR                     QIR             QTR             QIR           NA                             RR-P-2 i
E R
Test Frequency: QIR = Quarterly Pump Test i                                                                                                                                                                                                                                                                                                   .
Y E
4-1                                                                                         Rev.O                                               I r
NW Gulal (a:D isa!al theerl smal I
_ _ _ _ _ _ _ . , , _ _          . _ . . _ . . . . - . . - - - - _ - - - - - - - - - - - - - - - .          - - = - - - - - - - - -                                             ' - - ' ' ' '    - - - - ' ^ ' ^ ' " -     - ~ - - - ' ^ ^ ^
l-1202-P4-001 3D13 IX4D1133-1 C-8 NSCW Pump QTR QTR QTR QTR NA RR-P-2 1-1202-P4-002 3813 IX4DB133-2 C-5 NSCW Pump QIR QTR QTR QIR NA RR-P-2
+
i 1-1202-P4-003 3813 IX4DB133-1 C-5 NSCW Pump QTR QTR QTR QIR NA RR-P-2 1-1202-P4-004 3/313 IX4DB133-2 C-5 NSCW Pump QIR QTR' QTR QTR NA RR-P-2 1-1202-P4-005 3D13 IX4DB133-1 C-7 NSCW Pump QTR QTR QIR QTR NA RR-P-2 1-1202-P4-006 3D13 IX4DB133-2 C-7 NSCW Pump QIR QTR QTR QIR NA RR-P-2 1-1202-P4-007 3D13 IX4DB133-1 C4 NSCW Transfer Pump QTR QTR QTR QTR NA RR-P-2 1-1202-P4-008 3D13 IX4DB133-2 C-6 NSCWTransfer Pump QIR QIR QTR QIR NA RR-P-2 i
Test Frequency: QIR = Quarterly Pump Test I
i 4-1 Rev.O I
r
- - = - - - - - - - - -
- - - - ' ^ ' ^ ' " -
- ~ - - - ' ^ ^ ^


                    . _ . _ . ___m.._       .  . _ _ _      ..              ._._ _.                    _ _ _. . . . _ _ _ _ _                            . _          m . ._._                                ._ _        _    _      _ . . _
___m.._
O                                                                                               O                                                                                                                       O VEGP-1 PUMP TEST TABLE Compoecat Cooling Water - System 1203 Measured Pas ___;a.e & Fm LD. Number                       P&ID-Sheet No.         Coord,               Descristion QC/PQ                                                                                                              fe           R                 Q                               V         H           RR/ Remarks fagl 1       fa!D               (snel (heus)                               (en) 1-1203-P4-001     3/313         IX4 dbl 36             H-4                 CCW Pump                                                 Q1R         QTR                 QTR                           QTR         NA         RR-P-2 1-1203-P4-002     3/313         IX4DB136               D-4                 CCW Pump                                                 QTR       QTR                   QTR                         QTR           NA         RR-P-2               ;
m.._._
i 1-120'i-P4-003   3/313         IX4DB136               G-4                 CCW Pump                                                 QTR       QTR                   QTR                         QTR           NA         RR-P-2 1-1203-P4-004     3/313         IX4DB136               C-4                 CCW Pump                                                 QTR     QTR                     Q1R                       QTR             NA         RR-P-2 1-1203-P4-005     3/313         IX4DB136               F-4                 CCW Pump                                                 QTR     Q1R                     QTR                       QIR             NA           RR-P-2 1-1203-P4-006     3/313       IX4DB136                 B-4                 CCW Pump                                                 QTR   QTR                     Q1R                       QTR             NA           RR-P-2 Test Farquency: QTR = Quarterly Pump Test i
O O
O VEGP-1 PUMP TEST TABLE Compoecat Cooling Water - System 1203 Measured Pas ___;a.e & Fm LD. Number QC/PQ P&ID-Sheet No.
: Coord, Descristion fe R
Q V
H RR/ Remarks fagl 1 fa!D (snel (heus)
(en) 1-1203-P4-001 3/313 IX4 dbl 36 H-4 CCW Pump Q1R QTR QTR QTR NA RR-P-2 1-1203-P4-002 3/313 IX4DB136 D-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 i
1-120'i-P4-003 3/313 IX4DB136 G-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 1-1203-P4-004 3/313 IX4DB136 C-4 CCW Pump QTR QTR Q1R QTR NA RR-P-2 1-1203-P4-005 3/313 IX4DB136 F-4 CCW Pump QTR Q1R QTR QIR NA RR-P-2 1-1203-P4-006 3/313 IX4DB136 B-4 CCW Pump QTR QTR Q1R QTR NA RR-P-2 I
Test Farquency: QTR = Quarterly Pump Test L
r i
i t
i t
4-2                                                                                                                         Rev.O
4-2 Rev.O I


                                                                                . . . . . ~ . _ . . . . . _ _ . .               . - - ~       . ~ - -    - - - - . - - -  .. -
..... ~. _..... _ _..
VEGP-1 PUMP TEST TABLE                                                                                       .
. - - ~
t Safety lajection - System 1204 Measured Parameten & Freescacy LD. Number           CC/PC   P&ID-Sheet No. Coord. Description h       AE     9. Y         M           RR/ Remarks (a!!al     fa!!1 Onual h)       Daisl 1-1204-P6-003         2/212   IX4DB121       E-2   SIPump                                   QTR     QTR   QTR QTR- NA                 RR-P-2 1-1204-P6-004         2/212   IX4DB121       C-2   SIPump                                                                                                           '
. ~ - -
QTR       QTR   QTR QTR       NA           RR-P-2 Test Frequency: QTR = Quarterly Pump Test t
VEGP-1 PUMP TEST TABLE t
Safety lajection - System 1204 Measured Parameten & Freescacy LD. Number CC/PC P&ID-Sheet No.
Coord.
Description h
AE 9.
Y M
RR/ Remarks (a!!al fa!!1 Onual h)
Daisl 1-1204-P6-003 2/212 IX4DB121 E-2 SIPump QTR QTR QTR QTR-NA RR-P-2 1-1204-P6-004 2/212 IX4DB121 C-2 SIPump QTR QTR QTR QTR NA RR-P-2 Test Frequency: QTR = Quarterly Pump Test t
b i
b i
f r
f r
v i
v
4-3                                                               Rev.0 L
'i i
4-3 Rev.0 L
I
I


    . . - =   .  . . . . . . . . . - .      . - -    . . - - . - - . - . . - .                _ ~ _ ~ . . .               -        . . - . -                                                          .                            -                                                              - . - _      . .  . _ _ . . . -    . ~ . . . . . .
.. - =
O                                                                                               O                                                                                                                                                                                                                     O VEGP-1 PUMP TEST TABLE                                                                                                                                                                                                                                                             .
_ ~ _ ~...
I Residual Heat Removal- System 1205 i
. ~...
Measured Paranneters & Freauency                                                                                                                                                                                         1 LD. Number                             P&ID-Sheet No.                         Description                                                                                                                                                                                                          y CC/PC                                          Coord.                                                               P2                                 R                                                           .Q                                                                   M                 RR/ Remarks (Mal                                 (eG                                                   (smal &=ci                                                               fouel 1-1205-P6 @ l       2/212             IX4DB122                     F-4       RHR Pump                                                                                                                                                                                                                       NA
O O
                                                                                                                                          'QTR                               QTR                                                         Q1R                                                       QIR                         RR-P-2 1-1205-P6-002       2/212             IX4DB122                     G-4       RIIR Pump                                                 QTR                               QTR                                                         QTR                                                       QTR' NA                     RR-P-2                               ,
O VEGP-1 PUMP TEST TABLE I
i Test Frepency: QTR = Quarterly Pump Test i
Residual Heat Removal-System 1205 i
Measured Paranneters & Freauency 1
LD. Number CC/PC P&ID-Sheet No.
Coord.
Description P2 R
.Q y
M RR/ Remarks (Mal (eG (smal &=ci fouel 1-1205-P6 @ l 2/212 IX4DB122 F-4 RHR Pump
'QTR QTR Q1R QIR NA RR-P-2 1-1205-P6-002 2/212 IX4DB122 G-4 RIIR Pump QTR QTR QTR QTR' NA RR-P-2 i
Test Frepency: QTR = Quarterly Pump Test i
i f
i f
I 4-4                                                                                                                                                                                                             Rev.0
I 4-4 Rev.0 m
__ _ _ . .            _ _ _ . _ _ _ _ _  . _ . _          _ _ _ . . _ _ _ . . _ _ _ _ _ _ _ _ _ _ . . _ _ _ _ _ _ _ . _ . . _ _ _ _ _ . . . _ _ _ _ . _ _ _ _ _ _ _ _ - . _ _ _ _ _ _ . _ . _ _ . _ _ _ _ _ _                                                        ___m___


(,                                                                         t i
(,
t i
VEGP-1 FIIMP TEST TABLE r
VEGP-1 FIIMP TEST TABLE r
Contahment Spray - System 1206                                                                                                               i I
Contahment Spray - System 1206 i
Measured Parameters & Fr*==-=ar                               .
I Measured Parameters & Fr*==-=ar LD. N mber QC/PC P&ID-Sheet No.
LD. N mber         QC/PC       P&ID-Sheet No. Coord. Descristlos             Po     AE     _Q     Y       H               RR/ Remarks     :
Coord.
fadal   fa:D   Gmed fw=c)     trued l-1206-P6-001     2/212       IX4DB131       G-4   CS Pump                                                 NA QTR   QTR   QTR     QTR                     RR-P-2           !
Descristlos Po AE
l-1206-P6-002     2/212       IX4DB13i       C-4   CS Pump                                               NA QTR   QTR   QTR     QTR                     RR-P-2   i Test Frequency: QTR = Quarterly Pump Test 1
_Q Y
H RR/ Remarks fadal fa:D Gmed fw=c) trued l-1206-P6-001 2/212 IX4DB131 G-4 CS Pump QTR QTR QTR QTR NA RR-P-2 l-1206-P6-002 2/212 IX4DB13i C-4 CS Pump QTR QTR QTR QTR NA RR-P-2 i
Test Frequency: QTR = Quarterly Pump Test 1
I D
I D
4-5                                             Rev.O                         I
4-5 Rev.O I


                                                                                                                                                                                                                                                                .n .
.n.
VEGP-1 PUMP TEST TABLE Chemical & Volume Control - System 1208 Measured Parameters & Freauency I.D. N mber       CC/PC       P&lD-Sheet No. Coord. Description                                       P_o                                                         _AP_                                                     Q   V   N       RR/ Remarks Ot!!rl                                                               (a!!1                                                 framl da/wd Ltned 1-1208-P6-002     2/212       IX4DB116-2       G-4   CVCS - Centrifugal                             QTR                                                         QTR                                                       QTR QTR NA       RR-P                                                         Charging Pump t
VEGP-1 PUMP TEST TABLE Chemical & Volume Control - System 1208 Measured Parameters & Freauency I.D. N mber CC/PC P&lD-Sheet No.
1-1208-P6-003     2/212       IX4DBil6-2       C-4   CVCS - Centrifugal                             QTR                                                         QTR                                                         QTR QTR NA       RR r.y.
Coord.
Charging Pump 1-1208-P6-006      3/313        IX4DB118    . ,
Description P_o
D-4   CVCS-Boric Acid                               QTR                                                         QTR                                                         QTR QTR NA       RR-F-1, RR-P-2 Transfer Pump 1-1208-P6-007     3/313       IX4DB118         B-4   CVCS - Boric Acid                             QTR                                                         QTR                                                         QTR QTR NA       RR-P-1, RR-P-2 Transfer Pump Test Frequency: QTR = Quarterly Pump Test 4-6                                                                                                                                                                   Rev.0
_AP_
Q V
N RR/ Remarks Ot!!rl (a!!1 framl da/wd Ltned 1-1208-P6-002 2/212 IX4DB116-2 G-4 CVCS - Centrifugal QTR QTR QTR QTR NA RR-P Charging Pump t
1-1208-P6-003 2/212 IX4DBil6-2 C-4 CVCS - Centrifugal QTR QTR QTR QTR NA RR r.y.
Charging Pump D-4 CVCS-Boric Acid QTR QTR QTR QTR NA RR-F-1, RR-P-2 1-1208-P6-006 3/313 IX4DB118 Transfer Pump 1-1208-P6-007 3/313 IX4DB118 B-4 CVCS - Boric Acid QTR QTR QTR QTR NA RR-P-1, RR-P-2 Transfer Pump Test Frequency: QTR = Quarterly Pump Test 4-6 Rev.0


O                                                   O                                                                                                   O VEGP-1 PUMP TEST TABLE i
O O
Auxili;ry Feedwater - System 1302                                                                                                                                                         I Measured Parameters & Preemency LD. Number                       CC/PC P&ID-Sheet No. Coord. Description             Po                   V       N AP    Q                                                                    RR/ Remarks Gulal   fadl famed Gn w fraud                                                                   i 1-1302-P4-001                   3/313   IX4DB161-2     F-6   AFW Pump                 QTR     QTR   QTR     Q1R     NA                                                 RR-P-2
O VEGP-1 PUMP TEST TABLE i
                                                                  'Ihrbine Driven 1-1302-P4-002                     3/313 IX4DB161-2     D4     AFW Pump                                                                                                                 '
Auxili;ry Feedwater - System 1302 I
Q1R     Q1R   Q1R     Q1R     NA'                                                 RR-P-2 Motor Driven 1-1302-P4@3                       3/313 IX4DB161-2     B4     AFW Pump                                                 NA QTR     QfIR QTR   QTR                                                         RR-P-2
Measured Parameters & Preemency LD. Number CC/PC P&ID-Sheet No.
* Motor Driven Test Frequency: QTR = Quarterly Pump Test s
Coord.
Description Po AP Q
V N
RR/ Remarks Gulal fadl famed Gn w fraud i
1-1302-P4-001 3/313 IX4DB161-2 F-6 AFW Pump QTR QTR QTR Q1R NA RR-P-2
'Ihrbine Driven 1-1302-P4-002 3/313 IX4DB161-2 D4 AFW Pump Q1R Q1R Q1R Q1R NA' RR-P-2 Motor Driven 1-1302-P4@3 3/313 IX4DB161-2 B4 AFW Pump QTR QfIR QTR QTR NA RR-P-2 Motor Driven Test Frequency: QTR = Quarterly Pump Test s
v b
v b
b i
b i
F I
F I
1 L
1 L
4-7                                                                                     Rev.0             [
4-7 Rev.0
[


_ _ - - - .            - _ = - - - _ - - - - - _ - - _ _ - _ _ - - - _ - _ _ - - - - - - _ - - - _ - - - - _ _ - - - - - ._ - - __ - -- - --_-__----- -
- _ = - - - _ - - - - - _ - - _ _ - _ _ - - - _ - _ _ - - - - - - _ - - - _ - - - - _ _ - - - - -._ - - __ - -- - --_-__----- -
O                                                                                                                                                       O                                                                                                                                                                       O VEGP-1 PUMP TEST TABLE Safety Related (ESF) Chillers - System 1592 i
O O
Measured Parameters & Freaucacy                                                                                       i LD. Number,               CC/PC                           P&ID-Sheet No.                                                         Coord.           Description                                                                               P
O VEGP-1 PUMP TEST TABLE Safety Related (ESF) Chillers - System 1592 i
_3      AE     .Q                                                 V                 RR/Researks N!
Measured Parameters & Freaucacy i
fa:Isl   &!Il fanal (Mt!s)                                             frauni 1
LD. Number, CC/PC P&ID-Sheet No.
1-1592-P7-001             3813                             IX4DB221                                                               F-5             ESF Chilled Water                                                                         Q1R   QTR     QTR                                                 QTR   NA         RR-P-2 Pump 1-1592-P7-002           3B13                             IX4DB221                                                               C-5             ESF Chilled Water                                                                         Q1R   QTR     Q1R' Q1R'                                               NA         RR-P-2     ,
Coord.
Pump Test Frespency: QIR = Quarterly Pump Test i
Description P
4-8                                                                                                                                                       Rev.0
AE
_ . . . _ - _ _ _ _ _ _      ____u    -_    a__ ______    _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _                                                                            _ - _          +-_ _-  -'
.Q V
N!
RR/Researks
_3 fa:Isl
&!Il fanal (Mt!s) frauni 1
1-1592-P7-001 3813 IX4DB221 F-5 ESF Chilled Water Q1R QTR QTR QTR NA RR-P-2 Pump 1-1592-P7-002 3B13 IX4DB221 C-5 ESF Chilled Water Q1R QTR Q1R' Q1R' NA RR-P-2 f
Pump Test Frespency: QIR = Quarterly Pump Test l
i 4-8 Rev.0 u
a
+-


  . _                . __      ..~..._ _ _ _ _ _. _ __                              _ . _ . . - _ _ _  _ _ . __
..~..._ _ _ _ _ _. _ __
NSCWPumps
NSCWPumps (1-1202-P4-001, 002, 003, 004, 005, & 006) l l
!                                (1-1202-P4-001, 002, 003, 004, 005, & 006) l l       System Function Provide cooling water for the containment coolers, control l
System Function l
'                                                  building essential chiller condensers, various engineered safety feature pump motor and lube oil coolers, and the component cooling water and auxiliary component cooling             I water diesel generator jacket water heat exchangers and transfers the heat removed to the ultimate heat sink.
Provide cooling water for the containment coolers, control building essential chiller condensers, various engineered safety feature pump motor and lube oil coolers, and the component cooling water and auxiliary component cooling I
Quantity                                   6 Type l                                                  Vertical Line Shaft, 2 stage, selflubricated
water diesel generator jacket water heat exchangers and transfers the heat removed to the ultimate heat sink.
;      Manufacturer /Model                         Bingham-Willamette/18x27B VCM i
Quantity 6
Rated Capacity                             8600 gpm(each)
l Type Vertical Line Shaft, 2 stage, selflubricated Manufacturer /Model Bingham-Willamette/18x27B VCM i
Rated TotalDynamic Head                   230 feet Driver                                                                                                         i l
Rated Capacity 8600 gpm(each)
Type                                 Electric Motor l           Horsepower                           700                                                                 ;
Rated TotalDynamic Head 230 feet Driver i
Speed                                 1180 rpm Power Supply.                         4160V,60 Hz,3 phase Code Class                                 3                                                                     i Project Class ~                             313 Outline Drawing                             IX4AF02-32                                                             l i
Type Electric Motor l
Instruction Book                           1x4AF02-93                                                             1
l Horsepower 700 Speed 1180 rpm Power Supply.
;      Physical Location                         NSCW Pump House P&ID                                       1X4DB133-1, -2 l
4160V,60 Hz,3 phase Code Class 3
Surveillance Procedure                     14802-1 Pump Test Loop Diagrams                   ISI-D-201 through ISI-D-206 i     Test Parameter Sheets                     Page 5-3 through 5-8 l~
i Project Class ~
:                                                                                                                        )
313 Outline Drawing IX4AF02-32 l
i Instruction Book 1x4AF02-93 1
Physical Location NSCW Pump House l
P&ID 1X4DB133-1, -2 Surveillance Procedure 14802-1 Pump Test Loop Diagrams ISI-D-201 through ISI-D-206 i
Test Parameter Sheets Page 5-3 through 5-8 l~
)
e
e
!O                                                                                                                         ,
!O 5-1 Rev.0 I
1 5-1                                     Rev.0 I


__            .__m .- . - . _ . - - - _ - _ _ _ _ _.__.                                ._        .  - _ .  . . _ . _ _ _ ._ __
.__m
                                                                                                                                          ?
?
NSCW Transfer Pumps                                                               !
NSCW Transfer Pumps (1-1202-P4-007, 008)
(1-1202-P4-007, 008)
System Function 1
;        System Function                                                                                                                   1 Provides capability to transfer water between cooling tower                   :
Provides capability to transfer water between cooling tower basins.
basins.
Quantity 2
Quantity                                         2 i
i Type Vertical Line Shaft,2 stage, selflubricated i
;        Type i
1 Manufacturer /Model Bingham-Willamette/18x12A VCM i
Vertical Line Shaft,2 stage, selflubricated 1
Rated Capacity 600 gpm (each) i 4'
Manufacturer /Model                               Bingham-Willamette/18x12A VCM i
Rated TotalDynamic Head 110 feet Driver Type Electric Motor Horsepower 30 Speed 1765 rpm Power Supply 480V,60 Ih,3 phase Code Class 3
!        Rated Capacity                                   600 gpm (each) i 4
Project Class 313 O
;        Rated TotalDynamic Head                           110 feet                                                                       :
Outline Drawing IX4AF02-3 Instruction Book IX4AF02-95 PhysicalLocation NSCW Pump House P&ID 1X4DB133-1, -2 Surveillance Procedure 14801-1 Pump Test Loop Diagrams ISI-D-207 and ISI-D-208 Test Parameter Sheet Page 5-9 and 5-10 O
Driver Type                                         Electric Motor Horsepower                                   30 Speed                                       1765 rpm Power Supply                                 480V,60 Ih,3 phase Code Class                                         3 Project Class                                     313 O     Outline Drawing                                   IX4AF02-3 Instruction Book                                   IX4AF02-95 PhysicalLocation                                 NSCW Pump House                                                                 '
5-2 Rev.0
P&ID                                               1X4DB133-1, -2 Surveillance Procedure                             14801-1 Pump Test Loop Diagrams                           ISI-D-207 and ISI-D-208 Test Parameter Sheet                             Page 5-9 and 5-10 O
5-2                                   Rev.0


                                                                                                                                                                                                                        .m v                                                                            O~
.m O~
l Test Parameter Table - Pump 1-1202-P4-001                                                                                                                           ;
v
(Figure ISI-D-201)                                                                                                                                 j Instrumentation Utilized           Ref.               Acceptable                   Alert           Action Earameter               Test Freq. I.D. No.f4)     Bange         Req. Acc. Value             Range                         Bange           Bange                                           Comments                           ,
+
Speed (N)                     NA         NA             NA           NA           NA                 NA                           NA               NA                                             Constant speed driver Inlet                                                                                                                                                                                                                               ,
l Test Parameter Table - Pump 1-1202-P4-001 (Figure ISI-D-201) j Instrumentation Utilized Ref.
Pressure               Qtr         LI-1606         NA           (1)         NA                 NA ~                         NA               NA                                             Measure basin level               j (Pi)
Acceptable Alert Action Earameter Test Freq.
Outlet Pressure               Qtr         PI-2148         0-200         12%         NA                 NA                           NA               NA                                             NA                 .
I.D. No.f4)
(Po)                                               psig                                                                                                                                                                           &
Bange Req. Acc.
Differ Pressure               Qtr         (2)             NA           i2%         APr               .95 - 1.10APr                 .93 - <.95APr   <.93 or >l.10APr NA                                                               i (AP) l Flowrate               Qtr         FI-l 1760       0-15000       12%         Qr                 NA                           NA               NA                                             Flowrate is set at reference value (Q)                                                 gpm                                                                                                                                                                             j Vib.
Value Range Bange Bange Comments Speed (N)
Amp.                   Qtr         (3)             NA           15%         Vr                 5; 2.5Vr                     >2.5Vr - 6Vr     >6Vr or                                         1,A                               ,
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1606 NA (1)
(V)(5)                                                                                                                         or >.325 in/s   >.70 in/s N:tes:
NA NA ~
NA NA Measure basin level j
(Pi)
Outlet Pressure Qtr PI-2148 0-200 12%
NA NA NA NA NA (Po) psig Differ Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA i
(AP) l Flowrate Qtr FI-l 1760 0-15000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm j
Vib.
Amp.
Qtr (3)
NA 15%
Vr 5; 2.5Vr
>2.5Vr - 6Vr
>6Vr or 1,A (V)(5) or >.325 in/s
>.70 in/s
?
N:tes:
t
t
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
t
t
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instmments are utilized.
: 3. Portable vibration instmments are utilized.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                   j
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three onhogonal directions, one of which is the axial direction.                                                                                                   ;
j,
: 5. Measurements are taken on the upper motor-bearing housing in three onhogonal directions, one of which is the axial direction.
i L
i L
5-3                                                                                                             Rev.0                               {
5-3 Rev.0
                                                                                                        *  -rw -
{
-rw


(
(
Test ParameterTable - Pump 1-1202-P4-002 (Figure ISI-D-202)
Test ParameterTable - Pump 1-1202-P4-002 (Figure ISI-D-202)
Instrumentation Utilized                                               Ref.         Acceptable                                       Alert                                                                                         Action P_aramritt           Test Freq.                                             LD. No.(4)                                                               Range   Req. Acc.             Yalut         Bangt                                             Range                                                                                         Range         Comments                                 ;
Instrumentation Utilized Ref.
i Speed                                                                                                                                                                                                                                                                                                                                                                                                       l (N)                 NA                                                     NA                                                                       NA       MA                   NA           NA                                               NA                                                                                             NA             Constant speed driver                   l Inlet                                                                                                                                                                                                                                                                                                                                                                                                       i Pressure             Qtr                                                     LI-1607                                                                 NA       (1)                   NA           NA                                               NA                                                                                             NA             Measure basin level                     ;
Acceptable Alert Action P_aramritt Test Freq.
(Pi)                                                                                                                                                                                                                                                                                                                                                                                                       ,
LD. No.(4)
Outlet Piessure             Qtr                                                     PI-2149                                                                 0-200   12%                 NA             NA                                               NA                                                                                             NA             NA                 i (Po)                                                                                                                                                 psig                                                                                                                                                                                                                                                 ;
Range Req. Acc.
Differ.                                                                                                                                                                                                                                                                                                                                                                                                     !
Yalut Bangt Range Range Comments i
Pressure             Qtr                                                   (2)                                                                       NA       12%                 APr           .95 - 1.10APr                                     .93 - <.95APr                                                                               <.93 or >l.10APr NA (AP)                                                                                                                                                                                                                                                                                                                                                                                                         ,
Speed l
Flowrate             Qtr                                                     FI-l1763                                                                 0-15000 12%                 Qr             NA                                               NA                                                                                           NA               Flowrate is set at reference value (Q)                                                                                                                                                   gpm Vib.                                                                                                                                                                                                                                                                                                                                                                                                         ;
(N)
Amp.                 Qtr                                                   (3)                                                                       NA       i5%                 Vi             s 2.5Vr                                         > 2.5Vr - 6Vr                                                                                 >6Vr or         NA (V)(5)                                                                                                                                                                                                                                             or >.325 in/s                                                                                 >.70 in/s                                                 j Notes:
NA NA NA MA NA NA NA NA Constant speed driver l
: 1. Basin level indicator is utilized to determine icvel in feet.                                                                                                                                                                                                                                                                                                                                             [
Inlet i
: 2. DifTerential pressure is calculated using basin level (to determine suction head) and outlet pressure.                                                                                                                                                                                                                                                                                                    .
Pressure Qtr LI-1607 NA (1)
NA NA NA NA Measure basin level (Pi)
Outlet Piessure Qtr PI-2149 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr (2)
NA 12%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr FI-l1763 0-15000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA i5%
Vi s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s j
Notes:
: 1. Basin level indicator is utilized to determine icvel in feet.
[
: 2. DifTerential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.
: 3. Portable vibration instruments are utilized.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.                                                                                                                                                                                                                                                                             ,
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
t 5-4                                                                                                                                                                         Rev.0 I
t 5-4 Rev.0 I
i
i u
_ _ _ . _ _ . _ _    ._  u  - _                      -. _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ . . _ _ _ _ _ _ _ . _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ . _ . _ _ _ _              -
mm m
__mm______.__.__          _ _ _ . _ _ _ . _ _ _ . _ _ _ _                                ____m_ _______ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ . . _ _ . _ _ _ _ _ . _ _ _ _ _ _ . -                                      t---     .- _
t---


O                                                                                                                                                               O Test Parameter T$ble - Pump 1-1202-N-003 (Figure ISI-D-203)
O O
Instrumentation Utilized                                                                               Ref.             Acceptable   Alert                                                   Action Parameter                         Test Freg,                         LD. No.(4)                                       Range               Req. Acc.                                     Yalue               Range         Range                                                   Range                                                             Comments Speed (N)                               NA                                 NA                                               NA                   NA                                           NA                 NA           NA                                                       NA                                                                 Constant speed driver                   i U
Test Parameter T$ble - Pump 1-1202-N-003 (Figure ISI-D-203)
Inlet                                                                                                                                                                                                                                                                                                                                                                                           ;
Instrumentation Utilized Ref.
Pressure                         Qtr                               L1-1606                                         NA                   (1)                                           NA                 NA           NA                                                     NA                                                                 Measure basin level (Pi)
Acceptable Alert Action Parameter Test Freg, LD. No.(4)
Outlet Pressure                         Qtr                               PI-2152                                         0-200                 12%                                           NA                 NA           NA                                                     NA                                                                 NA                 i (Po)                                                                                                                 psig                                                                                                                                                                                                                                                                       ;
Range Req. Acc.
DitTer.
Yalue Range Range Range Comments Speed (N)
Pressure                         Qtr                               (2)                                             NA                     12%                                         APr                 .95 - 1.10APr .93 - <.95APr                                         <.93 or >l.10APr NA                                                                                           i f
NA NA NA NA NA NA NA NA Constant speed driver i
(AP)
U Inlet Pressure Qtr L1-1606 NA (1)
Flowrate                         Qtr                               FI-I 1762                                       0-15000               12%                                           Qr                   NA           NA                                                     NA                                                                   Flowrate is set at reference value (Q)                                                                                                                 gpm                                                                                                                                                                                                                                                                         ;
NA NA NA NA Measure basin level (Pi)
Vib.
Outlet f
A m p.                           Qtr                               (3)                                             NA                     i5%                                           Vr                   s 2.5Vr       >2.5Vr - 6Vr                                           >6Vr or                                                             NA (V)(5)                                                                                                                                                                                                                     or >.325 in/s                                         >.70 in/s                                                                                                     i f
Pressure Qtr PI-2152 0-200 12%
i t
NA NA NA NA NA i
Notes:                                                                                                                                                                                                                                                                                                                                                                                           1
(Po) psig DitTer.
                                                                                                                                                                                                                                                                                                                                                                                                  +
Pressure Qtr (2)
NA 12%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA i
f (AP)
Flowrate Qtr FI-I 1762 0-15000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
{
A m p.
Qtr (3)
NA i5%
Vr s 2.5Vr
>2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s i
f i
t Notes:
1
+
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                                                                                                 [
[
: 3. Portable vibration instruments are utilized.
[
L
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.                                                                                                                                                                                                                                                               ;
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
t i
t 1
5-5                                                                                                                                                         Rev.0                                     [
i 5-5 Rev.0
[
[
[
b
b
                            - - - .                                                                  _ _ _ _ _ _ _ . . _ _- _ _ _ .            .__.u--__ __.-_._.._. _ __ _ . . - _ - _ _ _ - _ _ _ _              e                                                                                                                                       w     o-         w<w w     w =-'i
.u--
e w
o-w<w w
w
=-'i


O                                                                                                                                                                     O                                                                                                                                                     O Test ParameterTable - Pump 1-1202-P4-004 (Figure ISI-D-204)
O O
Instrumentation Utilized                                                                                             Ref.     Acceptable                         Alert               Action Parameter                                             Iest Freg. I.D. No.f 4)                       Range ~                                               Req. Acc.                                               Value     Rangt                             Range               Range                                         Comments Speed (N)                                                   NA         NA                                 NA                                                   NA                                                       NA       NA                                 NA                 NA                                           Constant speed driver Inlet Pressure                                               Qtr       L1-1607                           NA                                                   (1)                                                     NA       NA                                 NA                 NA                                           Measure basin level (Pi) i
O Test ParameterTable - Pump 1-1202-P4-004 (Figure ISI-D-204)
,                                                  Outlet Pressure                                               Qtr       PI-2153                           0-200                                               12%                                                       NA       NA                                 NA                 NA                                           NA                                             i (Po)                                                                                                 psig 4
Instrumentation Utilized Ref.
DitTer.
Acceptable Alert Action Parameter Iest Freg.
Pressure                                               Qtr       (2)                               NA                                                 i2%                                                       APr       .95 - 1.10APr                     .93 <.95APr         <.93 or >l.10APr NA (AP)
I.D. No.f 4)
Flowrate                                               Qtr       F1-11765                           0-15000                                             12%                                                       Qr       NA                                 NA                 NA                                           Flowrate is set at reference value                                           ;
Range ~
(Q)                                                                                                   gpm Vib.                                                                                                                                                                                                                                                                                                                                                                                                           ,
Req. Acc.
A m p.                                                 Qtr       (3)                               NA                                                 15%                                                       Vr       s 2.5Vr                           > 2.5Vr - 6Vr       >6Vr or                                     NA (V)(5)                                                                                                                                                                                                                                                           or >.325 in/s       >.70 in/s                                                                                                                 ;
Value Rangt Range Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr L1-1607 NA (1)
NA NA NA NA Measure basin level (Pi) i Outlet Pressure Qtr PI-2153 0-200 12%
NA NA NA NA NA i
(Po) psig DitTer.
4 Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr F1-11765 0-15000 12%
Qr NA NA NA Flowrate is set at reference value l
(Q) gpm Vib.
I A m p.
Qtr (3)
NA 15%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s I
Notes:
Notes:
i
i
Line 525: Line 929:
: 4. At the discrenon of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. At the discrenon of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
5-6                                                                                                 Rev.0 t
5-6 Rev.0 t
i
i


O                                                                                                                                                                                                 O                                                                                       O Test Parameter Table - Pump 1-1202-P4-005 (Figure ISI-D-205)
O O
Instrumentation Utilized                                                                                                                             Ref.       Acceptable                   Alert               Action Parameter         Test Freq.             LD. No.(4)                             Range                                                                 Req. Ace.                                   Yalue       Range                       Range               Range           Comments Speed (N)               NA                     NA                                     NA                                                                     NA                                           NA         NA                           NA                 NA               Constant speed driver Inlet Pressure           Qtr                   LI-1606                                 NA                                                                   (1)                                           NA         NA                           NA                 NA               Measure basin level (Pi)
O Test Parameter Table - Pump 1-1202-P4-005 (Figure ISI-D-205)
Outlet Pressure           Qtr                   PI-2150                                 0-200                                                                 12%                                           NA         NA                           NA                 NA               NA                 i             l (Po)                                                                             psig Differ.
Instrumentation Utilized Ref.
Pressure           Qtr                   (2)                                     NA                                                                   i2%                                           APr       .95 - 1.10APr                 .93 <.95APr         <.93 or >1.10APr NA                                 ,
Acceptable Alert Action Parameter Test Freq.
(AP)                                                                                                                                                                                                                                                                                                                   !
LD. No.(4)
Flowrate           Qtr                   FI-l 1761                               0-15000                                                               t2%                                           Qr         NA                           NA                 NA               Flowrate is set at reference value l (Q)                                                                               gpm r
Range Req. Ace.
Yalue Range Range Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1606 NA (1)
NA NA NA NA Measure basin level (Pi)
Outlet Pressure Qtr PI-2150 0-200 12%
NA NA NA NA NA i
l (Po) psig Differ.
Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 <.95APr
<.93 or >1.10APr NA (AP)
Flowrate Qtr FI-l 1761 0-15000 t2%
Qr NA NA NA Flowrate is set at reference value l
(Q) gpm r
Vib.
Vib.
Amp.               Qtr                   (3)                                     NA                                                                   i5%                                           Vr         s 2.5Vr                       > 2.5Vr - 6Vr       >6Vr or         NA                                 l (V)(5)                                                                                                                                                                                                                                         or >.325 in/s       >.70 in/s i
Amp.
Qtr (3)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA l
(V)(5) or >.325 in/s
>.70 in/s i
(
(
Notes:                                                                                                                                                                                                                                                                                                                 f
f Notes:
: 1. Basin level indicator is utilized to determine level in feet.                                                                                                                                     _
: 1. Basin level indicator is utilized to determine level in feet.
f
f
: 2. DifTerential pressure is calculated using basin level (to vetermine suction head) and outlet pressure.                                                                                                                                                                                                             ;
: 2. DifTerential pressure is calculated using basin level (to vetermine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                       [
: 3. Portable vibration instruments are utilized.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                                                                                                       ;
[
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of w hich is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of w hich is the axial direction.
L i
L i
5-7                                                                         Rev.0                               [
5-7 Rev.0
[


O                                                                                                 O                                                                           O Test Parameter Table - Pump 1-1202-P4-006 (Figure ISI-D-206)
O O
Instrumentation Utilized               Ref.                 Acceptable       Alert               Action P_arameter         Test Freq.               I.D. Nol4)   Range             Rea. Ace. Yalue               Range           Range               Range             Comments r
O Test Parameter Table - Pump 1-1202-P4-006 (Figure ISI-D-206)
Speed (N)                 NA                       NA-           NA               NA           NA                   NA               NA                 NA                 Constant speed driver Inlet Pressure           Qtr                     LI-1607       NA               (1)           NA                   NA.             NA                 NA                 Measure basin level (Pi)
Instrumentation Utilized Ref.
Outlet Pressure           Qtr                     PI-2151       0-200           12%           NA                   NA               NA                 NA                 NA                 e (Po)                                                       psig                                                                                                                                               ,
Acceptable Alert Action P_arameter Test Freq.
i Differ.
I.D. Nol4)
Pressure           Qtr                     (2)           NA             i2%           APr                 .95 - 1.10APr   .93 - <.95APr       <.93 or >l.10APr NA (AP)
Range Rea. Ace.
Flowrate           Qtr                     FI-I1764     0-15000         12%             Qr                   NA               NA                 NA                 Flowrate is set at reference value     ,
Yalue Range Range Range Comments r
(Q)                                                       gpm i
Speed (N)
NA NA-NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1607 NA (1)
NA NA.
NA NA Measure basin level (Pi) l Outlet Pressure Qtr PI-2151 0-200 12%
NA NA NA NA NA e
(Po) psig i
Differ.
Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr FI-I1764 0-15000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm i
Vib.
Vib.
Amp.               Qtr                     (3)           NA             i5%             Vr                   s 2.5Vr         > 2.5Vr - (Vr       >6Vr or           NA (V)(5)                                                                                                                           or >.325 in/s       >.70 in/s Notes:
Amp.
Qtr (3)
NA i5%
Vr s 2.5Vr
> 2.5Vr - (Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s Notes:
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
Line 562: Line 1,010:
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
5-8                                                                         Rev.0 i
5-8 Rev.0 i


T                                                                                                                                                                                                               b v
T bv Test ParameterTable - Pump 1-1202-P4-007 (Figure ISI-D-207)
Test ParameterTable - Pump 1-1202-P4-007 (Figure ISI-D-207)
Instrumentation Utilized Ref.
Instrumentation Utilized                                                                     Ref.                                                       Acceptable     Alert       Action Paramtier           Test Freo.                             I.D. No.(4)                             Bange                         Rea. Acc.                             Value                                                       Range         Range         Range Comtatnis Speed                                                                                                                                                                                                                                                                                                                   .
Acceptable Alert Action Paramtier Test Freo.
(N)                   NA                                   NA                                       NA                           NA                                   NA                                                           NA           NA           NA               Constant speed driver
I.D. No.(4)
Bange Rea. Acc.
Value Range Range Range Comtatnis Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver
[
[
Inlet                                                                                                                                                                                                                                                                                                                   ,
Inlet Pressure Qtr LI-1606 NA (1)
Pressure             Qtr                                   LI-1606                                 NA                             (1)                                 NA                                                           NA           NA           NA               Measure basin level i
NA NA NA NA Measure basin level i
(Pi)
(Pi)
Outlet                                                                                                                                                                                                                                                                                                                   i Pressure             Qtr                                   PI-8895                               0-60                           12%                                   NA                                                           NA           NA           NA               NA                               ,
Outlet i
(Po)                                                                                               psig Differ.
Pressure Qtr PI-8895 0-60 12%
Pressure             Qtr                                   (2)                                     NA                             12%                                 APr                                                           .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA (AP)
NA NA NA NA NA (Po) psig Differ.
Flowrate             Qtr                                   FI-2156                                 0-1000                         12%                                 Qr                                                           NA           NA           NA               Flowrate is set at reference value (Q)                                                                                               gpm Vib.
Pressure Qtr (2)
Amp.                 Qtr                                   (3)                                   NA                             i5%                                 Vr                                                           s 2.5Vr       > 2.5Vr - 6Vr >6Vrer           NA (V)(5)                                                                                                                                                                                                                                             or >.325 in/s > 70 in/s Notes:                                                                                                                                                                                                                                                                                                                   !
NA 12%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr FI-2156 0-1000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vrer NA (V)(5) or >.325 in/s
> 70 in/s Notes:
t
t
: 1. Basin level indicator is utilized to determine level in feet.                                                                                                                                                                                                                                                        .
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                         [
: 3. Portable vibration instruments are utilized.
i           4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                                                                                                         !
[
i
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
I
I
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
5-9                                                                                                     Rev.0
5-9 Rev.0


O                                                                                                                                                                                 O                                                                                                                   ,
O O
Test ParameterTable - Pump 1-1202-P4-008
Test ParameterTable - Pump 1-1202-P4-008
                                                                                                                                            - (Figure ISI-D-208)
- (Figure ISI-D-208)
InstEnmentation Utilized                                                             Ref.                                                           Acceptable   Alert                                                           Action Parameter                     Test Freq. 1.D. No.f4) Range                                 Reg. Acc.                               Value                                                           Range         Range                                                           Range           Comments Speed                                                                                                                                                                                                                                                                                                                                               i (N)                           NA         NA           NA                                   NA                                       NA                                                             NA           NA                                                             NA             Constant speed driver                             ,
InstEnmentation Utilized Ref.
Inlet                                                                                                                                                                                                                                                                                                                                               t Pressure                     Qtr       LI-1607     NA                                   (1)                                       NA                                                             NA           NA                                                             NA             Measure basin Icvel                               j (Pi)
Acceptable Alert Action
Outlet Pressure                     Qtr       PI-8894     0-60                                 12%                                       NA                                                             NA           NA                                                             NA               NA                 i                             j (Po)                                                 psig DitTer.                                                                                                                                                                                                                                                                                                                                             ,
{
Pressure                     Qtr       (2)         NA                                   i2%                                     APr                                                             .95 - 1.10APr .93 - <.95APr                                                 < 93 or >l.10APr NA (AP)
Parameter Test Freq.
Flowrate                     Qtr       F1-2157     0-1000                               12%                                     Qr                                                               NA           NA                                                           NA               Flowrate is set at reference value               l (Q)                                                   gpm                                                                                                                                                                                                                                                                                           l i
1.D. No.f4)
Vib.                                                                                                                                                                                                                                                                                                                                               .t Amp.                         Qtr       (3)         NA                                 i5%                                       Vr                                                               s 2.5Vr       > 2.5Vr - 6Vr                                                 >6Vr or         .NA                                               !
Range Reg. Acc.
(V)(5)                                                                                                                                                                                                             or >.325 in/s                                                 >.70 in/s Notes:
Value Range Range Range Comments i
Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet t
Pressure Qtr LI-1607 NA (1)
NA NA NA NA Measure basin Icvel j
(Pi) l Outlet Pressure Qtr PI-8894 0-60 12%
NA NA NA NA NA j
i (Po) psig DitTer.
Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 - <.95APr
< 93 or >l.10APr NA (AP)
Flowrate Qtr F1-2157 0-1000 12%
Qr NA NA NA Flowrate is set at reference value l
(Q) gpm l
i Vib.
.t Amp.
Qtr (3)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or
.NA (V)(5) or >.325 in/s
>.70 in/s Notes:
}
1
1
: l. Basin level indicator is utilized to determine level in feet.                                                                                                                                                                                                                                                                                     +
: l. Basin level indicator is utilized to determine level in feet.
+
I
I
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.
: 3. Portable vibration instruments are utilized.
l
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.                                                                                                                                                                                                                   ,
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
I i
I i
5 - 10                                                                                                                                                       Rev.0                                             I i
5 - 10 Rev.0 I
i
 
- _. _ _.. _... ~ _ _, _..
O O
O NOTE: THIS IA A SIMPLIFIED DIAGRAM CV USED TO DEPICT A TEST CIRCUIT.
9446
'MC><]}---{MpCID ADDITION O
REFER TO THE P8.ID FOR DETAILS, g
(ggiD f6T4)
BLIND FLANGE D
TO 2' y ;
;g TE FC BLOVDOVN Q23)
(172)
M I, (4 3 plSPERSANT ADDITION
- 1642 (0Z6)
G V
0 S
3' (048)
C e4-20 g
16*
18' S
4 0MCB 4 0MCB QMCB 1602A 1608A 1634
[
18' 18' i
g y
l 11760 l
11761 l
j 11762 NSCVS
_~.v
~
b
. COMPONENTS 24 PDI PI PDI PI PDI PI I
11726 2148 11727 2150 (11729 2152 I
O 1668" L
SrC QMCB
-lbr"
' ll
-lbrl
' ll gh 1606 HV HV HV 1160 1160 l
i 11600 18'
,TO TGVER TO BASIN t
me G
m.AA: s
/N
/\\
/\\
1-1202-P4-001 1-1202-P4-005 1-1202-P4-003 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4-001 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
VATER TOVER r
c.
 
==
n c=-.
mawres.
nau m2
=>
nn.
-3
=-ars s4.-
as n
ita, a nY n
3 7 4.-98 Cf.
CV.
tFDAM TO EV M tF IM400 33-i JK
" " ~ ' " "
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT =$ = "
 
==
=c
 
== vs UNIT 1 "C C' m,
PUMP INSERVICE TESTING LOOP FOR neu.
NUCLEAR SERVICE COOLING VATER PUMP l-1202-P4-001 N/A N/A ISI-D-201 1 [F 1 2 i
i


_ _ . .         . _ _ _ _ . _ _ - . _ . .                                             - _ . _ _ . . _ . . . ~ _ _ , _ . .                                                       . . - . . .                             _ _ _ . _ _ _ _                                      .
-m.___._
O                                                                                                                                        O                                                                                                                                                                      O                                      -
._._m.._.
NOTE: THIS IA A SIMPLIFIED DIAGRAM                                                                                                                               CV USED TO DEPICT A TEST CIRCUIT.                                                                                                                       9446                                                                         'MC><]}---{MpCID ADDITION REFER TO THE P8.ID FOR DETAILS,                                                            O                                                                                                                                  g                                          (ggiD f6T4)                           BLIND FLANGE TE                        D                                                            TO                                                                                            2' y ;                          ;g                                                          ;
m.
FC                                BLOVDOVN                                                                                                                      (172)
.. _._ - __,~..-....__.
                                                                                      - 1642                                                                                                                                                                                                    Q23)
O O
M I, (4 3 plSPERSANT ADDITION VS                                                                                                  @                                              0 (0Z6)               G 3'                                                 (048)
O i
C                              e4-                                                                                                                                                                                                                          20                                                                                                         ;
NOTE: THIS IA A SIMPLIFIED DIAGRAM CV i
g                                                                                                                                                                                                                                                                                                                                            16*                    '-
USED TO DEPICT A TEST CIRCUIT.
18'                               S QMCB                                                            4 0MCB                                                                                                              4 0MCB 1602A                                                                   1608A                                                                                                               1634 18'                                                                                                           18'                                                                                                                                                                                                   i g                                                           y l           11760                                 l             11761                                                                                           l   . j 11762                                                 _
9447 M[>qj l'/pCID ADDITION (049)
REFER TO THE PS.ID FOR DETAILS.
(077) j-BLIND FLANGE b
TU
" l>4; l'AHf TE FC BLOVDOVN g
g
- 1643 I
if X
'yISPERSANT ADDITION Q68)
Cd797 (076)
>{
68 3'
C050)
O 24' 20' l6*
18' M QMCB g QHCB g QMCB 1603A 1609A 1635 18' W
1 g
g 1
l 11763 l
11764 l
11765 1
le 1-i
\\
-~*
669 NSCVS l
24-COMPONENTS t
- ~. v W
PDI PI PDI PI PDI PI ll l
~
11730 2149 11731 2151 11733 2153 l
i l O Il Il h 1669B
-dist:
'F g
Hist:
' ll
-Hell
' l' 1607 HV HV HV 11612 11613 11607 18'
, TO TOVER TO BASIN NAhMNLA
/g j
\\
E
/~\\
/~\\
1-1202-P4-002 1-1202-P4-006 1-1202-P4-004 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4-002 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
VATER TOVER L
my ante pr two sEs:kPruse appea arre2 arme.3 arva e areas moeurs s-e.-e.
sas vs ism,rm n, n
3 7-f46 Cs3 CVS LFhhTE TD KV 10 F SK430123-2 JK Southern Company Services, Inc.roR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT -> "
**" =
c"'
vs UNIT 1 PUMP INSERVICE TESTING LOOP FOR
~ ui a
,,n, p
.C NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-002 N/A N/A ISI-D-202 1 DF 1 2
 
\\
t V
v NOTE: THIS IA A SIMPLIFIED DIAGRAM CV USED TO DEPICT A TEST CIRCUIT.
9446
'M[><3l
"/F-ACID ADDITION N
REFER TO THE P8.ID FOR DETAILS.
(155)
(040) (074)
BLIND FLANGE FC OVDOVN
- 1642 I
/
X syISPERSANT ADDITION I'
(156)
(076)
(075)
S 3'
,048)
(
0 24' 20*
OMCB QMCB QMCB
[6' 18' H
1602A 1608A 1634 18' 18' 1
g l
11760 l
11761 l
11762 1
l a
{a 1668 g
NSCVS
NSCVS
_~.v                                                 .' '
~ ~ "
                                                                                                                                                                            ~
24. COMPONENTS
b                                                                      !!
-.v
24 . COMPONENTS I
- ~. "
PDI       PI                                                     PDI           PI                                                                                                           PDI     PI                                                                                       !
PDI PI PDI PI PDI PI
11726 2148                                                       11727 2150                                                                                                           (11729 2152 O               "
,li 11726 2148 11727 2150 11729 2152 h O h
1668" SrC                                QMCB                -lbr"                              ' ll                                                                   -lbrl                                      ' ll gh 1606           HV                                                                                                   HV HV                                           1160                                                                                             1160 i
i l b
11600                                                                                                                                                                                                                                                                                                               18'                                         ;
1668B
                                                                                                                                                                                                                                                                                                        ,TO TGVER                      TO BASIN                                 ,
-il;rll DMCB
t m.AA: s                                    me                                                                                                                                                                                    G
-ll>rll
                                    /N                                                                      /\                                                                                                                 /\
' ll
1-1202-P4-001                                                       1-1202-P4-005                                                                                                       1-1202-P4-003 NUCLEAR SERVICE                                                     NUCLEAR SERVICE                                                                                                       NUCLEAR SERVICE                                                                             1-1202-V4-001 COOLING VATER PUMP                                               COOLING VATER PUMP                                                                                                         COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                                                                                                                                                 VATER TOVER
-U>rl'
: c.     ==         n  c=-.                       mawres.                              nau        m2        =>           nn.                            -3            =-ars
''H GIT 1606 HV HV HV 1160 11606)
    .      s4.-       as  n      ita, a nY                                                  n 3       7 4 .-98  Cf. CV. tFDAM TO EV M tF IM400 33-i                                JK
 
            ''''''    "            " " ~ ' " "
==
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT =$                                                                                        = "                         ==               =c UNIT 1                                                                 ""*                                  == vs PUMP INSERVICE TESTING LOOP FOR                                                                                                       neu.           "C C'                      m, NUCLEAR SERVICE COOLING VATER
11600 18'
  -                                                                                                                                                                                        PUMP l-1202-P4-001                                                                                        N/A           N/A         ISI-D- 201                  1 [F 1 2            i
, TO TOVER TO BASIN N,_AhhNL V
/~\\
/~\\
/~\\
1-1202-P4-001 1-1202-P4-005 1-1202-P4-003 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4 -001 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
VATER TDVER
.,t o.,
wa.,v o.
-u
-u ms
 
=== s ve.-
.as vs i:=>r= m n
R
?-24-M Cs3 CVW L*3 ATE TO MV 96 EF INGDR173-0 JK e
=+=
=
 
==aw m onis MS Southern Company Services. Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT==* "
 
==
=c "m'
vs UNIT 1 PUMP INSERVICE TESTING LOOP FOR 5."S b"."
me,
~
muta
.cy.
NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-003 N/A N/A ISI-D-203 10F 1 2
 
O O
O NOTD THIS IA A SIMPLIFIED DIAGRAM CV M[><]l lM}--- ACID ADDITION USED TO DEPICT A TEST CIRCUIT.
9447 N
(041) (677)
BLIND FLANGE REFER TO THE PtID FOR DETAILS.
@ 2'; g D
TO TE FC BLOVDOVN g
- 1643 I
M X
yISPERSANT ADDITION s
I' W
M l
S 3'
(050)
O 24' 20' QMC5 QMCB QMCB 16' 18' H
3 3
1603A 1609A 1635 t
IO' I
I 1
t j 11765 j 11764 l
l 11763 l
1 1-I
\\
{n 1669 g
NSCVS 24' COMPONENTS
.v PDI PI PDI PI PDI PI
.I l
E 11730 2149 11731 2151 11733 2153 7
O l
1669B
-U;rij
' l}-
O B
--g;rll Hsrll t
' 'V 1607 HV HV H
11612 11613 11607 18'
, TO TOVER TO BASIN MAM LMMG m
i
/~\\
/~\\
/~\\
1-1202-P4-002 1-1202-P4-006 1-1202-P4-004 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE l-1202-V4-002 COOLING VATER PUMP CODLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE CDOLING (SPARE)
VATER TOVER
[
6w ears se o=,
uscuerase


                                                          -m.___._                            ._._m.._.                              m.    . . _._ - __,~..- ....__.                          .__        _ _ _ _ _ _ _ _ . _ . . _ _ _ _ . _                          -._
==4
O                                                                                                                           O                                                                                                         O                   i NOTE: THIS IA A SIMPLIFIED DIAGRAM                                                                                                                   CV                                                                                                                     i USED TO DEPICT A TEST CIRCUIT.
= = =
(049) 9447                                          M[>qj                        l'/pCID ADDITION REFER TO THE PS.ID FOR DETAILS.                                                                                                                                                                                 (077)            j-BLIND FLANGE TE                                 b                                    TU                                    " l>4;              l'AHf
ma
                                                                        - 1643                                                            FC                         BLOVDOVN I
=e 4 was acuses D
g                g if            X               'yISPERSANT ADDITION Q68)68        Cd797            (076) 3'       >{              C050)
9-**-84 BBS v3 IEILED Flut,tY FT l
O                              24'                                                                                                                                                                   20' g QMCB                                                              l6*
t de*-as css tvs urann to arv se y 1 4 set 33-a a
18'                          M QMCB                                                                         g QHCB 1603A                                                                          1609A                                                                      1635 18'           g W                  g                                                                             ,                      1 1
~
l             11763                                l          11764                                        _
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT K=
l               11765                _
8'a"
1                                                     le                                                                                              1-                                                                             i 669
=c UNIT 1
      \~. v
""' s o.5 v
                                  --,                        W                                                  ;-- ;                                      -~*
Ec=c corr r wtr i
NSCVS 24- COMPONENTS l
PUMP INSERVICE TESTING LOOP FOR ana mm.
t
c.
                                                                                                                                                                                                ~
wr, av.
PDI     PI                                         PDI                             PI                                                                   PDI     PI                                      ll      l 11730 2149                                            11731                        2151                                                                  11733 2153                                                                                          l i lO                                                Il @                                                                                            Il        h                                                           1669B
NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-004 N/A N/A ISI-D-204 1 [F 1 2
          -dist:               'F            g                Hist:                                       ' ll                                                -Hell                  ' l'                                                      __
 
1607          HV                                                                                     HV HV                                         11612                                                                                  11613                                                                                            --
O O
11607                                                                                                                                                                                                                                      18'                       :
O NOTE: THIS IA A SIMPLIFIED DIAGRAM CV M C)<%
                                                                                                                                                                                                                    , , TO TOVER                    ,  TO BASIN                 !
''MCID ADDITION USED TO DEPICT A TEST CIRCUIT.
NAhMNLA
9446 2'g (fy-)
                                /~\                                                                           /~\                                                                         /g \                                                                                 j 1-1202-P4-002                                                                1-1202-P4-006                                                                1-1202-P4-004 NUCLEAR SERVICE                                                           NUCLEAR SERVICE                                                                 NUCLEAR SERVICE                                   1-1202-V4-002 COOLING VATER PUMP                                                     COOLING VATER PUMP                                                                 COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                                                                 VATER TOVER my        ante      pr  two                        sEs:kPruse                                appea      arre2      arme.3          arva e    areas        moeurs
REFER TO THE PLID FOR DETAILS.
.         s-e.-e. sas  vs   ism ,rm n,                                                         n 3        7-f46    Cs3  CVS  LFhhTE TD KV 10 F SK430123-2                                      JK Southern Company Services, Inc.roR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT ->                      "                              **" =
Mt g
                                                                                                                                                                                                                "**                                c"'    vs UNIT 1 PUMP INSERVICE TESTING LOOP FOR                                ~ ui ap                  $$ $"            ,,n,  .C NUCLEAR SERVICE COOLING VATER                                                                                          '
BLIND FLANGE D
PUMP 1-1202-P4-002                        N/A            N/A          ISI-D- 202        1 DF 1    2
TO
;g W TE FC BLOVDOVN g
g 1642 I
f X
yISPERSANT ADDITION s
i
>S (075) 3' (048) 24' 20-l6*
18*
M QMCB 4 0MCB g DMCB 1602A 1608A 1634 18' W
1 g
g j
11760 l
11761 l
11762 1
1-la 1668 NSCVS
~ ~. "
~T"
'd 24. COMPONENTS
. s PDI PI PDI PI PDI P7 I,
i 11726 2148 11727 2150 11729 2152 g
gy g
h 1668B
-iwi y
-Hwl:
-iwl:
HV HV l1606 ) 1160 HV j
1160 11600 18'
, TO TGVER TO BASIN MJM A
GMM
/
\\
/ \\
/
\\
1-1202-P4-001 1-1202-P4-005 1-1202-P4-003 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4-001 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
VATER TOVER 7
av.
 
==
or ci usc.er==
-i
.,,u
-3 mi s s-e+
ma vs issu n n,
n I
7-# * -#
CSS Cwp treaYt 10 WEV 161F lx4Det33-t JK
"~"~
Southern Company Services. Inc.FOR Southern Nuclear Operoling Company i
V0GTLE ELECTRIC GENERATING PLANT K5=*


                                                                                                                                                            \
==
t                                                                                                                            V                                                                                                                            v NOTE: THIS IA A SIMPLIFIED DIAGRAM                                                                                                                        CV USED TO DEPICT A TEST CIRCUIT.
"c 5
N                                  9446                                                      'M[><3l                          "/F- ACID ADDITION REFER TO THE P8.ID FOR DETAILS.                                                                                                                                                                        (155)              (040) (074)                        BLIND FLANGE FC                                    OVDOVN
UNIT 1 PUMP INSERVICE TESkING LOOP FOR
                                                                                  - 1642                                                                                                                              '              I
",,,an a
                                                                                                                                                                                                                      /                  X            syISPERSANT ADDITION I'                                                                      (156)                (076)        (075) 3'            S                ,048)
$am mr erv.
(
NUCLEAR SERVICE COOLING VATER PUMP l-1202-P4-005 N/A N/A ISl-D-205 1 Ir 1 2
0                                24'                                                                                                                                                                                  20*
f
QMCB                                                                      [6' 18'                              H      OMCB                                                                                      QMCB 1602A                                                                                1608A                                                                                  1634 18'                                                                                              18' g
-s w
1 11760                                      l          11761                                                                                l                  11762 l                                                                                                                    _                                                                                      _
a
1                                                        _-                                                                                              l                                                                                              a
-t
{a
                                                                                                                                                                ~
g
                                                                                                                                                                    ~ "
1668 NSCVS
      -.v                            , ,                          ~."                                                    ,    ,                                                                                      ,
                                                                                                                                                                                                                                                            ,          24 . COMPONENTS PDI                            PI                                                                      PDI    PI                                            ,l PDI        PI                                                                                                                                                                                                                  i 11726 2148                                                        11727 2150                                                                                        11729 2152 hO                                                        h    @                                                                                          i l  b                                                                                1668B
        -il;rll                ' '!-            DMCB            -ll>rll                                          ' ll                                            -U>rl'                          ''H                                                          --
GIT              HV                                                                                      HV 1606 HV                                              1160
                                                                                                                                                                                                                                                                  ==
11606)                                                                                                              18' 11600
                                                                                                                                                                                                                                            , TO TOVER              ,        TO BASIN N,_AhhNL                                                                                                                                                                                                    V
                                /~\                                                                                    /~\                                                                                    /~\
1-1202-P4-001                                                                    1-1202-P4-005                                                                      1-1202-P4-003 NUCLEAR SERVICE                                                    NUCLEAR SERVICE                                                                                    NUCLEAR SERVICE                                            1-1202-V4 -001 COOLING VATER PUMP                                              COOLING VATER PUMP                                                                                      COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                                                                            VATER TDVER
        .,t      .,    o.,                            wa.,v o.                      -u                          -,      -u          -.        ms            === s
.      ve.-    .as    vs    i:=>r= m                                                n R      ?-24-M  Cs3      CVW    L*3 ATE TO MV 96 EF INGDR173-0                          JK e      =+=    =              ==aw m onis                                            MS Southern Company Services. Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT ==*                                    ""
                                                                                                                                                                                                                                              "                        ==
                                                                                                                                                                                                                                                                      "m'
                                                                                                                                                                                                                                                                                  =c UNIT 1                                                                             vs
                                                                                                                                                                                                                                                ~
PUMP INSERVICE TESTING LOOP FOR                                                       muta        5."S b"."                          me, .cy.
NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-003                                      N/A           N/A     ISI-D- 203                          10F 1 2


O                                                                                               O                                                                                 O NOTD THIS IA A SIMPLIFIED DIAGRAM                                                                                 CV USED TO DEPICT A TEST CIRCUIT.
O O
N                9447                               M[><]l                lM}--- ACID ADDITION BLIND FLANGE REFER TO THE PtID FOR DETAILS.                                                                                                                       (041) (677)
O t
TE                D                    TO                     @ 2'; g
NOTE: THIS IA A SIMPLIFIED DIAGRAM CV MC><]HyCID ADDITION '
                                                                                  - 1643                       FC            BLOVDOVN I
USED TO DEPICT A TEST CIRCUIT.
g M          X         yISPERSANT ADDITION s
9447 (049F 04L) (077)
I'S W          M          @                                              l 3'            (050)                                                                                                  ,
BLIND FLANGE REFER TO THE P8,ID FOR DETAILS.
O                              24'                                                                                                                      20' QMCB                                          QMCB                                            16' 18'                            H      QMC5                                                        3                                            3 1603A                                                             1609A                                           1635                                                                       t I
Q6J7) 2'(gW 0
IO'                    I                                                 1                                                              *                          .
g TO TV FC BLOVDOVN g
t l           11763                                   l   .              j 11764                 -
- 1643 I
l  . j 11765 1                                                    1-                                                          I
/
      \.v                          , ,                        .                                      , ,
X
{ng                        ,  ,
/
1669 24' NSCVS COMPONENTS               !
nISPERSANT ADDITION 8
PDI     PI                                                     PDI       PI                                     PDI     PI                           .I      l 11730 2149                                                       11731     2151                                     11733 2153 O                 '"
V ci6Tn cum L0z8) 3*
l
S g
                                                                                                                                                '"                              1669B
c e4 go.
        -U;rij              ' l}-            O B            --g;rll                                                      Hsrll                                                              .:
l6*
t 1607         HV                                                     HV
18*
          ' H'V                                          11612                                                  11613                                                                   :
M OMCB g DMCB g GMCB 1603A 1609A 1635 18" 18' I
11607                                                                                                                                                                               18'                            '
I a
                                                                                                                                                                      , TO TOVER                 TO BASIN
=
      '  MAM                                                                                            LMMG                                                                                        m                          i
l 11763 l
                              /~\                                                                 /~\                                             /~\
11764 l
1-1202-P4-002                                                       1-1202-P4-006                                   1-1202-P4-004 NUCLEAR SERVICE                                                     NUCLEAR SERVICE                                 NUCLEAR SERVICE                       l-1202-V4-002 COOLING VATER PUMP                                                 CODLING VATER PUMP                               COOLING VATER PUMP NUCLEAR SERVICE CDOLING (SPARE)                                                                           VATER TOVER                             [
11765
6w      ears      se  o=,                          uscuerase                          ==4    ===    ma  =e 4  was  acuses                                                                                              .
=p
FT                                                                                                                                  l D      9-**-84  BBS  v3    IEILED Flut ,tY t      de*-as  css  tvs    urann to arv se y 1 4 set 33-a                              a
=8
        ~        "            " " ' " "
=p i
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT K=              "                    8'a"  =c
1669 Q
                                                                                                                                                                  '"*                                v UNIT 1                  Ec=c    ,                ""' s o.5 wtr corr r i
NSCVS g
PUMP INSERVICE TESTING LOOP FOR                          ana          mm.      c.        wr,  av.
~'
NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-004                N/A          N/A      ISI-D- 204            1 [F 1 2
24*
COMPONENTS is
~
PDI PI PDI PI PDI PI ll ll
[
11730 2149 11731 2151 11733 2153 Nb j l h
O i
1669B d)(0
'U
-0)(C
'E
-lJfC
'l
~
1607 HV HV i
HV 1 612 11613
=,
11607 18
, TO TOVER.
TO BASIN M}A.) G L
G
/
\\
/~\\
/~\\
I 1-1202-P4-002 1-1202-P4-006 1-1202-P4-004 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4-002 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING f
(SPARE)
VATER TOVER t
e 1:
o.
scane mi me
=u
=s


O                                                                                                                                                                                                        O                                                                                          O NOTE: THIS IA A SIMPLIFIED DIAGRAM                                                                                                                                                                                            CV USED TO DEPICT A TEST CIRCUIT.                                                                                                                                                                                    9446                              M C)<%
==srs t
                                                                                                                                                                                                                                                                                                      ''MCID ADDITION REFER TO THE PLID FOR DETAILS.                                                                                                                                                                  Mt D                    TO g                  2'g
3-
                                                                                                                                                                                                                                                                                          ;g (fy-)W BLIND FLANGE TE 1642                    FC            BLOVDOVN                                  g          g
.=
'                                                                                                                                                                                                                                                                                      I yISPERSANT ADDITION f
wi nm. r=,n n
i X            s
9 7-f*-M CiB CVD LPenfE TO WV 30 IF IM450133-2 JK
                                                                                                                                                                                                                              >S
*~*"
                                                                                                                                                                                                                                                                    @                  @          (075)
Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERAT.NG PLANT 8ES=8 n
* 3'            (048)
= "
      "                                24'                                                                                                                                                                                                                                          20-g DMCB                                                          l6*
3 UNIT 1
18*                          M QMCB                                                                                                                                                                        4 0MCB 1602A                                                                                                                                                                        1608A                                        1634 18'                                                                  g W            g                                                                      ,
" " ' v5 PUMP INSERVICE TESTING LOOP FOR
1 j            11760                                                                                                l                                                            11761                                          l        11762 1                                                                                                                            1-                                                                                                la                                                                  1668 NSCVS
~,Enna SC C" m,
          ~
.y.
                                                                                                                                      ~T"                                                                                              -"
i NUCLEAR SERVICE COOLING VATER l
            ~."                        . s                                                                                                                                                                          , ,
PUMP 1-1202-P4-006 N/A N/A ISI-D-206 1 IF 1 2
                                                                                                                                                                                                                                                                  'd                              ,                    24 . COMPONENTS PI                                      PDI                                                I, PDI      PI                                                                                                                                                                PDI                                                      P7                                    i 11726 2148                                                                                                                                                                  11727 2150                                  g      11729 2152                                          gy g
h                                                                                                                            1668B
            -iwi                  ':                                y                                                                          -Hwl:                                                        ' ::                        -iwl:              ':                                                  _
HV                                                                                        HV HV                                              l1606                    j ) 1160                                                                                                                            1160                                                                            :-
11600                                                                                                                                                                                                                                                                                                    18'
                                                                                                                                                                                                                                                                                            , TO TGVER              ,  TO BASIN MJM                                                                                                                                                                                                        A                                            GMM
                                    / \                                                                                                                                                                          / \                                          / \
1-1202-P4-001                                                                                                                                                                1-1202-P4-005                                  1-1202-P4-003 NUCLEAR SERVICE                                                                                                                                                                NUCLEAR SERVICE                                NUCLEAR SERVICE                                1-1202-V4-001 COOLING VATER PUMP                                                                                                                                                          COOLING VATER PUMP                                COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                                  VATER TOVER                            7 av.     ==        or  ci                                                                            usc.er==                                                                                      -i    -,    .,,u  -.    -3    mi s
    .      s-e+      ma    vs    issu n     n,                                                                                                                                                        n I      7-# * -#  CSS  Cwp    treaYt 10 WEV 161F lx4Det33-t                                                                                                                                          JK
    *                 "            "~"~
Southern Company Services. Inc.FOR Southern Nuclear Operoling Company
                                                                                                                                                                                                                                                                                                  "                    ==    "c V0GTLE ELECTRIC GENERATING PLANT K5=*          ""'                        """ **
UNIT 1                                                                     '
PUMP INSERVICE TESkING LOOP FOR                       " ,,,an a          $am              mr      erv.
NUCLEAR SERVICE COOLING VATER PUMP l-1202-P4-005                        N/A           N/A       ISl-D- 205        1 Ir 1 2 f
                                              . . _ _ _ _ , _ . _ . _ . . _ . . . - - - _ . - - . _ . - - - _ _ . - - - - - - _ _ - - . - - _ - - - - _ _ - - - _ _ - - - - _ _ - - - - - - - -                                                                      - _ _ . . . ---            -              -s            w              a  -t


O                                                                                                             O                                                                                                                                                                 O t
O O
NOTE: THIS IA A SIMPLIFIED DIAGRAM                                                                                                             CV USED TO DEPICT A TEST CIRCUIT.
O NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT.
(049F 9447                                                                MC><]HyCID ADDITION '
REFER TO PLID FOR DETAILS HV FI 1670 2156 pg 8895 a ls, v
REFER TO THE P8,ID FOR DETAILS.                                                                                                                                                                              04L) 0              (077)                                              BLIND FLANGE TV                        g                                  -      TO                                          Q6J7) 2'(gW
s g e
                                                                                  - 1643                                      FC                            BLOVDOVN                                                                        g I                        '            nISPERSANT ADDITION
e LO M"
                                                                                                                                                                                                            /
g GMCB FI HV 2 54
8 X                  /
.LD ei 4
VS                                                                        ci6Tn          cum                  L0z8) 3*                                  g c                              e4                                                                                                                                                                            go.                                                                                                            .
4 6-PI 6'
g GMCB                                                                                                       l6*
2155 PDI 0" O 11728 PI 1606 8894 QMC O
18*                          M OMCB                                                                  g DMCB 1603A                                                                  1609A                                                                                    1635 18"                                                                                18'                    ,
PDI m
I                                                        I                                                                                  a                                                                                                                                  =
1173 r
11763                                  l                  11764                                                              l                11765 l                                                                                                        _                                                                                        _
WMAMM JM)JM.
                                                                                                                                                          =p                                                                                        i                                                                          -
M
        =p                                                      =8                                                                                                                                                                                1669 g                                                                                  ~'
/
Q                                                                                                                                                NSCVS              ,
/_
        -                          > <                        ~
3 r 1-1202-P4-007 1-1202-P4-008 TRANSFER PUMP 1-1202-V4-001 TRANFFER PUMP 1-1202-V4-002 NUCLEAR SERVICE COOLING NUCLEAR SERVICE COOLING VATER TGVER VATER TOVER
                                                                                                            ><                                                                                      is                                                                    24* COMPONENTS PDI     PI                                                   PDI           PI                                                                      PDI                  PI                                          ll ll                                                                                [
* tv-SmTc BT cier"5 KstBFTEDI AFFRJ APFH2 appet3 arFR4 APPR.S E3tWKS
11730 2149                                                    11731      2151                                                                      11733 2153                                                                                                                                              :
.-e.-
Nb                                                    jl        @                                                                              h    O                                                                                1669B i
so.
d)(0                  'U                              -0)(C                              'E                                                    -lJfC                                  'l                                                              __
n
                                                                                                                                                                                                                                                                  ~
:mes,= m n
1607          HV                                                                      HV HV                                            1 612                                                                  11613                                                                                                                        =,          18 i
i i
11607
1-e.-es cs cv.
                                                                                                                                                                                                                                  , , TO TOVER .                                               TO BASIN                          ,
up.m m u-uv i a
M}A .) G                                                                                                L                                                                                        G                                                                                                                  ,
: u. san-e av. m ut l
                                / \                                                                    /~\                                                                                        /~\
U'I "$
1-1202-P4-002                                                      1-1202-P4-006                                                                                  1-1202-P4-004 NUCLEAR SERVICE                                                  NUCLEAR SERVICE                                                                            NUCLEAR SERVICE                                            1-1202-V4-002 COOLING VATER PUMP                                              COOLING VATER PUMP                                                                    COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                                                                                    VATER TOVER                                                                     t e          1:            o.                            scane                            mi          me        =u        -.         =s                  ==srs                                                                                                                                                                    t
[.",", [
.       3-   -
[y"3 Southern Company Services. Inc.FOR Southern Nuclear Operating Company VOGTLE ELECTRIC GENERATING PLANT "5=*
                    .=   wi    nm. r= ,n                                                n 9      7-f*-M      CiB  CVD    LPenfE TO WV 30 IF IM450133-2                            JK                                                                                                                                                                                                                                      ,
"a" "c
*                  "           *~*"
UNIT 1 PUMP INSERVICE INSPECTION LOOP Ra.
Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERAT.NG PLANT 8ES=8                                            n                                            = "                                       3 UNIT 1                                    ""'                                              " " ' v5                                                !
527 s,an
PUMP INSERVICE TESTING LOOP FOR                                                  ~ ,Enna                      SC C"                                        m,    .y.
~
i NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-006                                              N/A         N/A               ISI-D- 206                                      1 IF 1 2 l                                                                                                                                                                                                                    .
FOR TRANSFER PUMP l-1202-P4-007 N/A N/A ISI-D-207 10F 1 3


O                                                                                                                                                                                    O                                                                                                          O NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT.
NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT.
REFER TO PLID FOR DETAILS HV                                                 FI pg 1670                                         2156 8895                                                                                                                                                                                                                           , ,                                   _
t REFER TO PLID FOR DETAILS HV FI 1670 2156 pg 8895
e a ls,                                v s g                                                            e LO g GMCB                                                      FI                                     HV                                                         M" 2 54                                                                                                                                                                                                                            .LD                                                                      .
,l, n_
ei                          . .
ii i i LO QMCB i
4                                                        ..
FI HV 2166 2157 1671 167A pg 2154 LO
4 6-PI 6'                  2155                                                                                            , ,
[
PDI 0" O 11728 PI 1606                                                                                                       8894                                           QMC O
Mll l l
m                                                         PDI r
[
1173 WMAMM                                                                                                                                                                                    JM)JM.                                                           M
6-PI PDI V
                                                                                                                                              /                                                                                                                                                         /_                              3 r 1-1202-P4-007                                                                                                                                         1-1202-P4-008 TRANSFER PUMP                                                 1-1202-V4-001                                                                               TRANFFER PUMP                                 1-1202-V4-002 NUCLEAR SERVICE COOLING                                                                                                                       NUCLEAR SERVICE COOLING VATER TGVER                                                                                                                                VATER TOVER
QMCB 11728 PI 1606 8894 QMCB i
* tv-  SmTc                                    BT                      cier"5                                                                      KstBFTEDI                    AFFRJ          APFH2  appet3          arFR4    APPR.S  E3tWKS
PDI m
  .     .-e.-                             so.                                  n                         :mes,= m                                                                n i
1173 r
i      1-e.-es                          cs                              cv.                             up.m m u- uv i a                                  u. san-e av. m        ut l      U'I                              "$                                                              [ ." ,", [                                                              [y"3                                                      Southern Company Services. Inc.FOR Southern Nuclear Operating Company VOGTLE ELECTRIC GENERATING PLANT "5=*                                          "            "a"      "c UNIT 1                                ~    "
+
PUMP INSERVICE INSPECTION LOOP FOR TRANSFER PUMP Ra. 527              s,an l-1202-P4-007                              N/A      N/A  ISI-D- 207      10F 1 3
WhAAA.A.A> N.
A A A.A.A.A d v vNJhhh
/~\\
I f
/ \\
y 1-1202-P4-007 1-1202-P4-008 TRANSFER PUMP 1-1202-V4-001 TRANSFER PUMP 1-1202-V4-002 l
NUCLEAR SERVICE COOLING NUCLEAR SERVICE COOLING VATER TOVER VATER TOVER e
.,c o,
mawen.
-2 nm nm
-4
.-s 5-e4-e4 iss vi uma nBe n, n
3
,-24-95 CSS tv5 tatafE TO luem Ev 14 dBG IN4BBi33-e EEV. W J.I I
e s-i4-se Cte vs apK3 pg gag ggyi DeWEE9 Pt 2135 TU ef34 WLW MB Southern Company Services, Inc.FOR Southern Nuclear Operating Company 3
e-e-w
;w.
..c 3
m V0GTLE ELECTRIC GENERATING PLANT K''K8


NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT.                t REFER TO PLID FOR DETAILS HV                    FI 1670                    2156 pg 8895                                                                                                  , ,                                ,l,                                  ,
==
n_                            i i LO ii QMCB                                                                                "
'"e UNIT 1 PUMP INSERVICE INSPECTION LOOP
FI                        HV                          i 2166                        2157                    1671                        167A pg 2154                                                                                                    LO                                        ,
~,. m
[                      Mll                l l                                    [
",'.~v,.*h*"
6-PI PDI                                                                                                                                V                                                              !
m1,
QMCB 11728 PI 1606                                                                                              QMCB                                                                                    i 8894 m                            PDI r                          1173                                                                                                        .
~
                                                                                                                                                                                                                +
.v.
WhAAA.A.A> N .                                                    A A A.A.A.A d v                        vNJhhh
                                                            /~\                    I f                                                        / \                                  y 1-1202-P4-007                                                                                                1-1202-P4-008 TRANSFER PUMP                                        1-1202-V4-001                                          TRANSFER PUMP                      1-1202-V4-002                      l NUCLEAR SERVICE COOLING NUCLEAR SERVICE COOLING VATER TOVER                                                                              VATER TOVER e  .,c        ,  o,                                              mawen.      -2      nm    nm  -4    .-s        --.
. 5-e4-e4  iss  vi  uma nBe n,                                              n 3  ,-24-95  CSS  tv5  tatafE TO luem Ev 14 dBG IN4BBi33-e EEV. W              J.I vs  apK3 pg gag ggyi DeWEE9 Pt 2135 TU ef34                WLW    MB e  s-i4-se e-e-w Cte
            ;w.        .                        . .c          3              m                                    Southern Company Services, Inc.FOR Southern Nuclear Operating Company 3
                                                                                                                                                                      "              ==     '"e V0GTLE ELECTRIC GENERATING PLANT K''K8    ""'                """ "'
UNIT 1 PUMP INSERVICE INSPECTION LOOP
                                                                                                                                                                ~
                                                                                                                                                                      ~ ,. m       ",'.~v,.*h*"     m1,     .v. -
FOR TRANSFER PUMP
FOR TRANSFER PUMP
                                                                                                                              .1-1202-P4-008                     N/A     N/A     ISI-D- 208     1 IF 1 3
.1-1202-P4-008 N/A N/A ISI-D-208 1 IF 1 3


J CCWPumps (1-1203-P4-001, 002, 003, 004, 005, & 006)
J CCWPumps (1-1203-P4-001, 002, 003, 004, 005, & 006)
; p)u System Function Remove waste heat from the spent fuel pool heat exchangers, RHR heat exchangers and the RHR pump seal coolers during plant operation, plant cooldown and during a        '
; p)
System Function Remove waste heat from the spent fuel pool heat u
exchangers, RHR heat exchangers and the RHR pump seal
}
}
postulated post-accident condition.~ This heat energy is then transferred by the component cooling water heat
coolers during plant operation, plant cooldown and during a postulated post-accident condition.~ This heat energy is then transferred by the component cooling water heat exchangers to the NSCWS. The CCWS functions as an intermediate system between a radioactive fluid system and 1
'                                                        exchangers to the NSCWS. The CCWS functions as an intermediate system between a radioactive fluid system and the non-radioactive NSCWS, which operates at a higher 1                                                                                                                              l system pressure. This arrangement greatly reduces the i
the non-radioactive NSCWS, which operates at a higher system pressure. This arrangement greatly reduces the i
probability ofradioactive fluid leakage to the enviroment by         ;
probability ofradioactive fluid leakage to the enviroment by means of the NSCWS.
4                                                        means of the NSCWS.                                                 J Quantity -                                   6
J 4
!                                                                                                                              )
Quantity -
!          Type.
6
:                                                        Horizontal, centrifugal, single-stage, split volute with l
)
mechanical seals                                                       '
Type.
Horizontal, centrifugal, single-stage, split volute with mechanical seals
[
[
Manufacturer /Model                           Ingersoll-Rand /10x18 SE
Manufacturer /Model Ingersoll-Rand /10x18 SE l
:                                                                                                                              l Rated Capacity                               5000 gpm (each) i~
Rated Capacity 5000 gpm (each) i~
Rated Total Dynamic. Head                     160 feet iO I
Rated Total Dynamic. Head 160 feet iO I
Driver Type Electric Motor, Westinghouse, LAC-LLD, 5008-S
Driver Type Electric Motor, Westinghouse, LAC-LLD, 5008-S Horsepower 300
;              Horsepower                             300                                                                   {
{
;              Speed                                   1761 rpm j               Power Supply                           4160V,60 Hz,3 phase Code Class                                   3 1
Speed 1761 rpm j
;        Project Class                                 313 j         Outline Drawing i                                                      IX4AF01-67 & 1X4AF01-70 l
Power Supply 4160V,60 Hz,3 phase Code Class 3
Instruction Book                             X4AF01-136 Physical Location Aux Bldg, Level A, Rooms R-A03 & R-A05 i         P&ID                                         1X4DB136 i
1 Project Class 313 j
Surveillance Procedure                       14803-1 i
Outline Drawing IX4AF01-67 & 1X4AF01-70 i
;        Pump Test Loop Diagrams                     ISI-D-209 through ISI-D-214
l Instruction Book X4AF01-136 Physical Location Aux Bldg, Level A, Rooms R-A03 & R-A05 i
  . w
P&ID 1X4DB136 i
;        Test Parameter Sheets                       Page 6-2 through 6-7 6-1                                   Rev.O i                                                                                                                               !
Surveillance Procedure 14803-1 i
                                                                      .,              1
Pump Test Loop Diagrams ISI-D-209 through ISI-D-214 w
Test Parameter Sheets Page 6-2 through 6-7 6-1 Rev.O i
1


O                                                                             O                                                                                         O4 Test Parameter Table - Pump 1-1203-P4-001                                                                                                 ,
O O
(Figure ISI-D-209)
O4 Test Parameter Table - Pump 1-1203-P4-001 (Figure ISI-D-209)
Instrumentation Utilized         ~ Ref.         Accepuble             Alert               Action Earameler         Int Freq.         1.D. No.01   Range         Rea. Acc.     Yalue       Range                 Range               Range           Comments                                         ;
Instrumentation Utilized
Speed                                                                                                                                                                                                     .
~ Ref.
(N)                 NA             NA             NA             NA             NA         NA                     NA                   NA               Constant speed driver                           !
Accepuble Alert Action Earameler Int Freq.
l Inlet Pressure           Qtr             PI-1878       0-60         12%             NA         NA                     NA                   NA               NA                                               i (Pi)                                               psig Outlet Pressure           Qtr             PI-1858       0-200         12%             NA         NA                     NA                   NA               NA                         i                   y (Po)                                               psig                                                                                                                                                   !
1.D. No.01 Range Rea. Acc.
Differ.
Yalue Range Range Range Comments Speed (N)
Pressure           Qtr             NA(1)         NA           12%             APr       .90 - 1.10APr         NA                   <.90 or >l.10APr NA                                               f (AP)
NA NA NA NA NA NA NA NA Constant speed driver l
Flowrate           Qtr             F1-11794       0-10000       12%             Qr         NA                   NA                   NA               Flowrate is set at reference value (Q)                                               gpm                                                                                                                                                   t Vib.
Inlet Pressure Qtr PI-1878 0-60 12%
Amp.               Qtr             (2)           NA             i5%             Vr         s 2.5Vr               > 2.5Vr - 6Vr         >6Vr or         NA (V)(4)                                                                                                           or >.325 in/s         >.70 in/s Notes:
NA NA NA NA NA i
(Pi) psig Outlet Pressure Qtr PI-1858 0-200 12%
NA NA NA NA NA i
y (Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA f
(AP) j Flowrate Qtr F1-11794 0-10000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm t
Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA
[
(V)(4) or >.325 in/s
>.70 in/s Notes:
i
i
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
Line 864: Line 1,665:
: 3. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
6-2                                                                   Rev.0
l 6-2 Rev.0
                                                                                                          - - - -                  _ --    _ _ - - - -  . - - _ - - - - - -          _    - - - _ - -n
- -n


Test Parameter Table - Pump 1-1203-P4-002 (Figure ISI-D-210)
Test Parameter Table - Pump 1-1203-P4-002 (Figure ISI-D-210)
Instrumentation Utilized                                                   Ref.                                                                 Acceptable                               Alert         Action Parameter           Irst Freq.     I.D. No.f3)         Range         Rec.Acc.                                         Value                                                                 Range                                     Rangt         Range             Comments Speed NA             NA                 NA           NA                                               NA                                                                   NA                                         NA           NA               Constant speed driver (N) inlet Pressure           _ Qtr           PI-1881           0-60           12%                                             NA                                                                   NA                                         NA           NA               NA (Pi)                                                   psig Outlet Pressure           Qtr             PI-1859           0-200         12%                                             NA                                                                     NA                                         NA           NA               NA                 i (Po)                                                   psig Differ.
Instrumentation Utilized Ref.
Pressure           Qtr             NA(1)             NA             12%                                             APr                                                                   .90 - 1.10APr                             NA           <.90 er > l.10APr NA (AP)
Acceptable Alert Action Parameter Irst Freq.
Flowrate           Qtr             F1-11795         0-10000         12%                                             Qr                                                                     NA                                         NA           NA               Flowrate is set at reference value (Q)                                                   gpm Vib.
I.D. No.f3)
Amp.               Qtr             (2)               NA             i5%                                             Vr                                                                   s 2.5Vr                                     > 2.5Vr - 6Vr >6Vr or           NA (V)(4)                                                                                                                                                                                                                                 or>.325 in/s >.70 in/s Notes:
Range Rec.Acc.
Value Range Rangt Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure
_ Qtr PI-1881 0-60 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1859 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er > l.10APr NA (AP)
Flowrate Qtr F1-11795 0-10000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or>.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
6-3                                                                                                                                           Rev.0 E         -_                _    _-.      ._.        ._ _ _ _ _ . . .      _ . _ _ . . _ _ _ . _ _ _ _ _ . _ . . _ _ _ . _ _ . . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ , _                                    _ _ _ _ _ _ _ _
6-3 Rev.0 E


O                                                                                                             O                                                                                                                                                                                                               O '
O O
i Test Parameter Table - Pump 1-1203-P4-003 (Figure ISI-D-211)
O i
Instrumentation Utilized                                               Ref.     Acceptable             Alert                                       Action Paramettr         Test Frea.       I.D. NoJ3)     Range               Rea. Acc.                                 Value     Range                 Bange                                       Range                                     Comments Speed (N)                 NA               NA             NA                   NA                                       NA       NA                     NA                                         NA                                       Constant speed driver Inlet
Test Parameter Table - Pump 1-1203-P4-003 (Figure ISI-D-211)
  . Pressure           Qtr             PI-1879       0-60                 12%                                       NA       NA                     NA                                         NA                                       NA (Pi)                                               psig Outlet Pressure           Qtr             PI-1860       0-200                 2%                                       NA       NA                     NA                                         NA                                     NA                                                                                                 i (Po)                                               psig Differ.
Instrumentation Utilized Ref.
Pressure           Qtr             NA(1)         NA                   12%                                       APr       .90 - 1.10APr         NA                                         <.90 or >l.10APr NA                                                                                                                               ,
Acceptable Alert Action Paramettr Test Frea.
r (AP)
I.D. NoJ3)
Flowrate           Qtr             F1-11796     0-10000               12%                                       Qr       NA                     NA.                                         NA                                     Flowrate is set at reference value (Q)                                               gpm Vib.
Range Rea. Acc.
Amp.               Qtr             (2)           NA                   i5%                                       Vr       5 2.5Vr               > 2.5Vr - 6Vr                               >6Vr or                               NA (V)(4)                                                                                                                                             or >.325 in/s                               > 70 in/s b
Value Range Bange Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet
. Pressure Qtr PI-1879 0-60 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1860 0-200 2%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP) r Flowrate Qtr F1-11796 0-10000 12%
Qr NA NA.
NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr 5 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
> 70 in/s b
Notes:
Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                                                                                                                                 i
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
i
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-beanng housing and in the axial direction on each accessibie thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-beanng housing and in the axial direction on each accessibie thrust bearing housing.
i                                                                                                                                                                                                                                                                                                                                                   .
i 6-4 Rev.0 l
6-4                                                                                                       Rev.0 l                                                                                                                                                                                                                                                                                                                                                   :
4
4


p                                                                                     s.
p s.
O                                                                           V                                                                                                   :
O V
Test Parameter Table - Pump 1-1203-P4-004 (Figure ISI-D-212)
Test Parameter Table - Pump 1-1203-P4-004 (Figure ISI-D-212)
Instrumentation Utilized           Ref.         Acceptable             Alert             Action Parameter           Test Freq.     1.D. No.01     Range         Rea. Acc. Value         Range                   Range             Range           Comments Speed (N)                 NA             NA             NA             NA         NA           NA                     NA                 NA               Constant speed driver Inlet Pressure           Qtr             PI-1882       0-60           12%         NA           NA                     NA                 NA               NA (Pi)               BC(2)                         psig Outlet                                                                                                                                                                                       "
Instrumentation Utilized Ref.
Pressure           Qtr             PI-1861       0-200         12%         NA           NA                     NA                 NA               NA                 i (Po)                                               psig Differ.
Acceptable Alert Action Parameter Test Freq.
Pressure           Qtr             NA(1)         NA             i2%         APr           .90 - 1.10APr         NA                 < 90 or >l.10APr NA (AP)
1.D. No.01 Range Rea. Acc.
Flowrate           Qtr             F1-11797       0-10000       t2%         Qr           NA                     NA                 NA               Flowrate is set at reference value   :
Value Range Range Range Comments Speed (N)
(Q)                                               gpm Vib.
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-1882 0-60 12%
Amp.               Qtr             (2)           NA             i5%         Vr           <; 2.5Vr               > 2.5Vr - 6Vr       >6Vr or         NA                                   !
NA NA NA NA NA (Pi)
(V)(4)                                                                                                             or >.325 in/s       >.70 in/s 5
BC(2) psig Outlet Pressure Qtr PI-1861 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA i2%
APr
.90 - 1.10APr NA
< 90 or >l.10APr NA (AP)
Flowrate Qtr F1-11797 0-10000 t2%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr
<; 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s 5
Notes:
Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
Line 912: Line 1,769:
i
i
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
6-5                                                                     Rev.0 m_--___                    - . . . - _ __              _
6-5 Rev.0 m --


O                                                                                                                                                                   '
O O
O Test Parameter Table - Pump 1-1203-P4-005 (Figure ISI-D-213)
Test Parameter Table - Pump 1-1203-P4-005 (Figure ISI-D-213)
Instrumentation Utilized                                 Ref.                                                                 Acceptable             Alert                                                             Action Parameter                           Test Freo. I.D. NoJ3)       Range                           Rea. Acc. Value                                                                 Bange                   Range                                                             Bange                                               Comments Speed (N)                                   NA.       NA                 NA                             NA           NA                                                                   NA                     NA                                                                 NA                                                 Constant speed driver Inlet Pressure                             Qtr       PI-1880           0-60                               2%       NA                                                                   NA                     NA                                                               NA                                                 NA (Pi)                                                               psig Outlet Pressure                             Qtr       PI-1862           0-200                         12%           NA                                                                   NA                     NA                                                               NA                                                 NA                 i (Po)                                                               psig DifTer.                                                                                                                                                                                                                                                                                                                                                                     I Pressure                             Qtr       NA(1)             NA                           i2%           APr                                                                   .90 - I .10APr         NA                                                               <.90 or >I.10APr NA                                                                         >
Instrumentation Utilized Ref.
(AP)
Acceptable Alert Action Parameter Test Freo.
Flowrate                             Qtr       FI-l 1798         0-10000                       12%           Qr                                                                   NA                     NA                                                               NA                                                   Flowrate is set at reference value (Q)                                                                 gpm                                                                                                                                                                                                                                                                                                     .
I.D. NoJ3)
Vib.
Range Rea. Acc.
Amp.                                 Qtr       (2)               NA                           i5%             Vr                                                                   s 2.5Vr                 > 2.5Vr - 6Vr                                                   >6Vr or                                             NA (V)(4)                                                                                                                                                                                                         or >.325 in/s                                                   >.70 in/s                                                                                   i i
Value Bange Range Bange Comments Speed (N)
t I.
NA.
NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-1880 0-60 2%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1862 0-200 12%
NA NA NA NA NA i
(Po) psig DifTer.
I Pressure Qtr NA(1)
NA i2%
APr
.90 - I.10APr NA
<.90 or >I.10APr NA (AP)
Flowrate Qtr FI-l 1798 0-10000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s i
i t
I.
Notes:
Notes:
: 1. DifTerential pressure is calculated as, AP = Po - Pi
: 1. DifTerential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                                                                             l
: 2. Portable vibration instruments are utilized.
l
: 3. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
6-6                                                                                                                                                                                                           Rev.0 I
6-6 Rev.0 I
t-
t-


                                                                                          /m                                                                         em Os                                                                         U                                                                           U Test Parameter Table - Pump 1-1203-P4-006 (Figure ISI-D-214)
/m em Os U
Instrumentation Utilized           Ref.         Acceptable     Alert             Action Parameter         Test Frea.       I.D. No.(3)   Range         Rea. Ace. Value         Range           Range             flanFe             Comments '
U Test Parameter Table - Pump 1-1203-P4-006 (Figure ISI-D-214)
Speed (N)                 NA             NA             NA             NA         NA           NA             NA               NA                 Constant speed driver Inlet Pressure           Qtr             PI-1883       0-60         12%         NA           NA             NA               NA                 NA (Pi)                                               psig Outlet Pressure           Qtr             PI-1863       0-200         12%         NA           NA             NA               NA                 NA                 i (Po)                                               psig Differ.
Instrumentation Utilized Ref.
Pressure           Qtr             NA(1)         NA           12%         APr           .90 - 1.10APr   NA               <.90 er >l.10APr NA (AP)
Acceptable Alert Action Parameter Test Frea.
Flowrate          Qtr    -        FI-Il799     0-10000       12%         Qr             NA             NA               NA                 Flowrate is set at reference value (Q)                                               gpm Vib.
I.D. No.(3)
Amp.               Qtr             (5)           NA             i5%         Vr             s 2.5Vr         > 2.5Vr - 6Vr   >6Vr or             NA (V)(4)                                                                                                     or >.325 in/s   >.70 in/s N ites:
Range Rea. Ace.
Value Range Range flanFe Comments '
Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-1883 0-60 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1863 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er >l.10APr NA (AP)
FI-Il799 0-10000 12%
Qr NA NA NA Flowrate is set at reference value Flowrate Qtr (Q) gpm Vib.
Amp.
Qtr (5)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s N ites:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
6-7                                                             Rev.O u           -
6-7 Rev.O u


_. _ .~_ ._ . . . _ . _.                         . . _ . . . _ . . - _ . . - . . . _ _ _ _ _ .                                      -.          . - . . . _ . - - = . .          _ -        . - _ . _              -. .-            . _ - . . . . _ . .
_.~_._... _. _.
O                                                                                                         O                                                                                             o/
. -... _. - - =..
M OMCB                                                     PI         gy                           NOTE: THIS IS A SIMPLIFIED                     -
O O
HV                       PI             1852A                                                   1858                        FI               DIAGRAM USED TO DEPICT 11803 11800                   1878                                                                                                 1179               A TEST CIRCUIT. REFER LD                                                                   A                                                     '                              * '"' * * " " * "
o/
l N '-                                     '
M OMCB PI gy NOTE: THIS IS A SIMPLIFIED HV PI 1852A FI DIAGRAM USED TO DEPICT 1858 11803 11800 1878 1179 A TEST CIRCUIT. REFER LD A
16'    'I !.'
l N '-
1[                 1-1203-P4-001               (030)
'I 1[
                                                                                                                                                                                                              }
(030) 16' 1-1203-P4-001
}
CMPNT. CLG.
CMPNT. CLG.
OMC                 VATER PUMP HV                       PI                 54 1860 U
OMC VATER PUMP HV PI 54 U
1879                                                                                  11 4         1179 11801 10'                                         LU LO                                                                   '
1860 11 4 11801 1879 1179 10' LU LO c
c              lN!                     !    l 16'    'I       I',
lN!
th                 1-1203-P4-003               O                                                                              ,
l
CMPNT. CLG.
'I I',
VATER PUMP                                                                           18' OMC                                                                                       FI                                                             i PI         HV         1179 HV                       PI               856                                                   1862         11805 1180                     1880                                                                                                                 I                           CCVS LO                                                                                                                                    l                       18'         =    COMPONENTS l 10' e                 gi                       ha l                                                                             !
th O
16'  'I       I',
16' 1-1203-P4-003 CMPNT. CLG.
th \               1-1203-P4-005 CMPNT. CLG.
VATER PUMP 18' OMC FI i
VATER PUMP 20'                                                                                           (SPARE)                                                                                                                             i
PI HV 1179 HV PI 856 1862 11805 1180 1880 I
_L            18' i! <      Is.
CCVS l
T                     LO HV 4'
18' LO l 10' e gi ha l
COMPONENT CLG. VATER                                               11807
=
                                                                                'g       gi'                                                            HEAT EXCHANGER COMPONENT CLG. VATER LO                                                                                                  [1 03-a-001 SURGE TANK                                               HV 1-1203-T4-001                                           11806 L
COMPONENTS
T LO                                                                                               1866 --                                                                           _
'I I',
z .,
th \\
EV. hfE     l   BY   De*D                     K--                                             mPytJ mPPRA         appe.4 arse 2          appa3   N 8   h           ME     vt   IISLEB ftbr PET                                                     fl i     r-e+=     css     cw   wrte = is.eenas arv n                                             JJC Southern Company Services, Inc.FOR Southern Nuclear Operating Company VOGTLE ELECTRIC GENERATING PLANT =8=*                         "                      **    ''c UNIT 1                     "'''                          **=* vs PUMP INSERVICE TESTING LOOP FOR COMPONENT CDOLING VATER PUMP m       EU'                       n     .v.
16' 1-1203-P4-005 CMPNT. CLG.
1-1203-P4-001                         N/A               N/A     ISI-D- 209           IT1 2
VATER PUMP I
20' (SPARE) 18' i!
Is.
i
_L T
LO HV 4'
COMPONENT CLG. VATER 11807
'g gi HEAT EXCHANGER
?
[1 03-a-001 COMPONENT CLG. VATER LO SURGE TANK HV 1-1203-T4-001 11806 L
T LO 1866 --
z.,
EV.
hfE l
BY De*D K--
mPytJ mPPRA arse 2 appe.4 appa3 N
8 h
ME vt IISLEB ftbr PET fl i
r-e+=
css cw wrte = is.eenas arv n JJC Southern Company Services, Inc.FOR Southern Nuclear Operating Company VOGTLE ELECTRIC GENERATING PLANT =8=*
''c UNIT 1
**=* vs PUMP INSERVICE TESTING LOOP FOR m
EU' n
.v.
COMPONENT CDOLING VATER PUMP 1-1203-P4-001 N/A N/A ISI-D-209 IT1 2


                        ._    m . __..               . - . . - - . _ - - . . - - - -- -                      __      ._- -    . . . . -          --.- - -       . - - - .              . - - - - _ . -        . -. .
m. __..
v                                                                                              b                                                                                      Cf*~
b Cf*~
i v
i M QHCB PI HV NOTE: THIS IS A SIMPLIFIED HV PI 853 FI 1859 11811 DIAGRAM USED TO DEPICT r
11808 1881 II79 A TEST CIRCUIT. REFER LO TO THE P&ID FOR DETAILS.
LD A,
lN i
16' 1-1203-P4-002 g4, CMPNT. CLG.
OMCB VATER PUMP HV PI 855 1861 11 2 11797 i
118C9 1882 10' LO LO c
lN:
lN:
I, h
O 16' 1-1203-P4-004 CMPNT. CLG.
VATER PUMP 18' PI HV 1179 O
HV PI 857 1863 11813 11810 1883 f
CCVS LO
; 10, g g;
fu, l
18'
=
COMPONENTS O
h 16' 1-1203-P4--006 CMPNT. CLG.
VATER PUMP j
20' (SPARE) 18',l i
_a_
i i
i i
M QHCB                                        PI             HV                       NOTE: THIS IS A SIMPLIFIED PI           853 HV                                                                      1859        11811 FI             DIAGRAM USED TO DEPICT                     r 11808            1881                                                                                II79              A TEST CIRCUIT. REFER LO                                  TO THE P&ID FOR DETAILS.
T LO i
LD                                                    A,                 lN            -
HV 4*
i 16' 1-1203-P4-002                                                              g4, CMPNT. CLG.
COMPONENT CLG. VATER 11815 gi HEAT EXCHANGER i
OMCB          VATER PUMP HV             PI           855 1861        11 2 118C9            1882                                                                                11797                                                        i 10'                               LO LO                                                           c I,'
1-203-G-002 COMPONENT CLG. VATER LO SURGE TANK HV l-p 1-1203-T4-002 11814 T
:                  lN:              lN:
t e a) 1T 1867 ~ ~ ~
16'       !
i ar.
h            1-1203-P4-004          O                                                                           <
mir o,
CMPNT. CLG.
= _. _
VATER PUMP                                                                  18' O                                                          857                                          PI           HV       1179 HV               PI                                                       1863 1883                                                                      11813 11810                                                                                                                f                             CCVS fu,                                  18' LO                                                    ; 10, g            g;                              l                                      =     COMPONENTS 16'       !        O h              1-1203-P4--006 CMPNT. CLG.
-u
VATER PUMP 20'                                                                                 (SPARE) j
-u
_a_          18' ,l i    !.
.-2
 
==.
m-=
0 N
353 wt IIstE3 Ftp PET FI a
i v-e.-es can ews urmece m u. ems avi, JJC b
*~"~
Southern Company Services. Inc.FOR Southern Nuclear Operating Company
[
V0GTLE ELECTR ENERATING PLANT "_""
 
==z can
: a. m. mar PUMP INSERVICE TESTING LOOP FOR n.
aum re
=v.
COMPONENT COOLING VATER PUMP f
1-1203-P4-002 N/A N/A ISI-D-210 1 IF 1 2
 
O O
O M OMCB PI HV NOTD THIS IS A SIMPLIFIED HV PI 852Al FI 1858 11803 DIAGRAM USED TO DEPICT 11800 1878 1179 A TEST CIRCUIT. REFER to,
To TME etiD roR nEraitS.
, t o.,
t,g
,N.,
1h
~
16' 1-1203-P4-001 g4, CMPNT. CLG.
QMC VATER PUMP HV PI 854 1860 11 4 I
11801 1979 1179 10' LO t
LD lN:
16' 1
1-1203-P4-003 O
e CMPNT. CLG.
OMC g FI PI HV 1179 HV PI 56 1862 11805 I!B0 1880 f
CCVS LD l 10' c
.N' I'
I
=
CU""U"ENTS N N IM (034) 16' 1-1203-P4-005 CMPNT. CLG.
VATER PUMP 20' (SPARE) 18',l li 2
i i
i i
T                   LO                                               i' 4*                                                                                                                                                                                HV COMPONENT CLG. VATER                                      11815 gi                                              HEAT EXCHANGER                                                                                  i COMPONENT CLG. VATER LO                                                                                  1- 203-G-002                                                                                ;
T LO HV 4'
SURGE TANK                                        HV                                         l-e a)            1 1-1203-T4-002                                    11814 T                                                                                                t T
COMPONENT CLG. VATER 11807 ig l HEAT EXCHANGER 1-1203- & 001 COMPONENT CLG. VATER LD SURGE TANK HV l_
1867 ~ ~ ~
1-1203-T4-001 11806 T
ar . mir          o,                            = _ . _                              -u  -u  .-2    ==.      . m-=
t wa>
i 0      N      353    wt    IIstE3 Ftp PET                                              FI                                                                    a i      v-e.-es can  ews    urmece m u. ems avi,                                        JJC
1-T
                  "            *~"~
~~
b                                                                                                                      Southern Company Services. Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTR            ENERATING PLANT  "_""        "
                                                                                                                                                                  ==z                            can a. m. mar PUMP INSERVICE TESTING LOOP FOR                                n.            .        aum        re =v.
COMPONENT COOLING VATER PUMP 1-1203-P4-002                      N/A              N/A        ISI-D- 210          1 IF 1  2
 
O                                                                                                      O                                                                                                                                                                                              O M OMCB                                                                                  PI                  HV                                                                        NOTD THIS IS A SIMPLIFIED HV      PI                      852Al                                                                                  1858                                              FI 11803                                                                                          DIAGRAM USED TO DEPICT 11800    1878                                                                                                                                                        1179                                                          A TEST CIRCUIT. REFER t,g                                                        , t o. ,                                                                  to ,                                                                                              To TME etiD roR nEraitS.
                                                                                                                      .      ~                                                  .,N.,
16'                                            1h                  1-1203-P4-001                                                                                                                                                          g4, CMPNT. CLG.                                                                                                                                                                                                                  ;
QMC                VATER PUMP                                                                                                                                                                                                                    ,
HV        PI                      854 1860    11 4                                                                                                                                        I 11801    1979                                                                                                                                                      1179 10'                                                                      LO                                                                                                                                              t LD                                                                ::                                                                                                                                                                                                                  '
:                                                        lN:                :
16'                                            1                    1-1203-P4-003                                              O                                                                                                                                              e CMPNT. CLG.
OMC g                                                                                          PI FI 56                                                                                                  HV                      1179 HV        PI                                                                                                              1862 1880                                                                                                                      11805 I!B0                                                                                                                                                                                                                f CCVS LD NN l 10' c                                                '
                                                                                                                                                                            .N'                  I'                I                                                                                                =      CU""U"ENTS          ,
16'                                            IM 1-1203-P4-005                                            (034)
CMPNT. CLG.
VATER PUMP                                                                                                                                                                                                                    ;
20'                                                                                        (SPARE) 2 18',l                    i                      li  i T                                                          LO 4'
HV COMPONENT CLG. VATER                                                                                                                   11807 ig l                                                                                                             HEAT EXCHANGER COMPONENT CLG. VATER LD                                                                                                                                    1-1203- & 001                                                                                                                                           .
SURGE TANK                                       HV                                                                                           l_
wa>                1-1-1203-T4-001                           11806 T                                                                                                                                                         t T                                                                                         ~~
1866 r
1866 r
w   =re   e,       =,                             =_.                                     -.. -,        -,    -. m.
w
e   -    ms         vs   usan rar m                                                         1                                                                                                                                                                                                                                             >
=re e,
L_ F-944   CSS         CVS tPtm7ED 19 II490BM IEV B9                                       _ JC
=,
  *      *  "                " ~ " " ' "
=_.
Southern Company Services. Inc.rOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT                                                           8t=* * "                                                                                   8"'     "
m.
UNIT 1                           "'"                                                                                    """      "5 Sta.E                             espg                                               CIgrTBEES EBe SEIT PUMP INSERVICE TEST 1HG LDDP FDR                                                                                                                                           .                              .  =v.
e ms vs usan rar m 1
COMPONENT COOLING VATER PUMP 1-1203-P4-003                                   N/A                                                   N/A                   ISI-D- 211         1 (F 1 2
L_ F-944 CSS CVS tPtm7ED 19 II490BM IEV B9
_ JC
" ~ " " ' "
Southern Company Services. Inc.rOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT 8t=* * "
8"'
UNIT 1 "5
Sta.E espg CIgrTBEES EBe SEIT PUMP INSERVICE TEST 1HG LDDP FDR
=v.
COMPONENT COOLING VATER PUMP 1-1203-P4-003 N/A N/A ISI-D-211 1 (F 1 2


O                                                                                                                                                                                                                               O                                                                                                                                         O S QMCB                                                                                           PI                                                                               NOTE: THIS IS A SIMPLIFIED '
O O
PI                               A                                                                                                         HV HV                                1 1859        11811 FI                               DIAGRAM USED TO DEPICT 11808 1881                                                                                                                                                                               1179                             A TEST CIRCUIT. REFER 10' -                               hD                                                                           TO THE P8.ID FOR DETAILS.
O 1
L,D
S QMCB PI HV NOTE: THIS IS A SIMPLIFIED '
                                                                                                                                                              '  p'                       g                                                                       '.          ~           i.Ni                            ,
HV PI 1
16'                                 14'                                                                                               O 1-1203-P4-002                                                                                                                         g4 CMPNT. CLG.
A FI DIAGRAM USED TO DEPICT 1859 11811 11808 1881 1179 A TEST CIRCUIT. REFER 10' -
OMC                                                        VATER PUMP HV            PI                      55                                                                                                                                                  II 18 1        11 11809  1882                                                                                                                                                                                11797 10'                                  LD LO                                                                                                      '
hD TO THE P8.ID FOR DETAILS.
                                                                                                                                                                                                                                                                                              'Ni                  l                                                                                                                                        i 16'  '    N                        gh                                                      1-1203-P4-004                                                                                                                                                            '
L,D i.Ni p'
g
~
16' 14' 1-1203-P4-002 O
CMPNT. CLG.
CMPNT. CLG.
DMC                                                                                                                                                           Fb PI             HV                               1179 HV         PI                     857                                                                                               1C63 1883                                                                                                                                          11813 11810                                                                                                                                                                                                             J                                                       CCVS fu,                                                                            18' LO                                                                                                    '          10, g           ,q                                                 l                                                       =                       COMPONENTS 16*  !    N 1                                                     1-1203-P4-006                               O                                                                                                                                                             [
g4 OMC VATER PUMP HV PI 55 II 18 1 11 11809 1882 11797 10' LD LO
'Ni l
i N
gh 16' 1-1203-P4-004 CMPNT. CLG.
DMC Fb PI HV 1179 HV PI 857 1C63 11813 11810 1883 J
CCVS 10, g
,q fu, l
18' LO
=
COMPONENTS N
1 1-1203-P4-006 O
16*
[
CMPNT. CLG.
CMPNT. CLG.
VATER PUMP 20'                                                                                                                                                                                           (SPARE)
VATER PUMP 20' (SPARE) 18',I Ii
_a_                            18' ,I     i                   Ii n
_a_
T                                           LO                                                                               !
i n
4' HV COMPONENT CLG. VATER                                                                                 11815 HEAT EXCHANGER COMPONENT CLG. VATER LO SURGE TANK                                                 HV-                                                                                                       -I-                                                                                                                                                     i e a>                                                          A 1-1203-T4-002                                                   11814 T                                                                                                                                                         -
T LO HV l
T                                                                                                                                               ''                                                                                                                                                                                                       '
4' COMPONENT CLG. VATER 11815 L
                                      @                                                                                                                                                                                                3867                                  --GD                                                                                                                                                                           :
HEAT EXCHANGER
      =v.                   ==             e,             oo>                                                                                             =_.                                   -,    -,                    -2                               m.                 . =>-n e                   we.-         ==                         vs                             nun ne m                                                                                       ti i                   t-e.-es     esa                       ews                           woms is inesias av i,                                                                       JX                                                                                                                                                                                                                                                           i e                   e-e-es     m                     Auts                                 arme                             s acams                                                 ope Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT                                 mismus n                                           sm==                         =                 ,
[
UNIT 1                                         ""'                                              ""* vs PUMP INSERVICE TESTING LOGP FOR                                                                         u.        ".E                                       . av.
COMPONENT CLG. VATER LO SURGE TANK HV-
COMPONENT CDOLING VATER PUMP 1-1203-P4-004                                               N/A                             N/A       ISI-D- 212                             I [F 1 2     1 e
-I-i 1-1203-T4-002 11814 T
m       . . . - _ _ _ _ _    ___._m        . _ _ . _ . _ . - . _ _ _ _ _ _ _ . _ _ . _ _ _ . _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ . _                                      ___m_        _ _ _ _ _ _ _ _ - - _ _ _ _ _ , - - - _ _ _ _              - - -
e a>
                                                                                                                                                                                                                                                                                                                                        .<+--nww   +-w~+-.     . - _ _ _                          .--w                                   - -      *    +
A T
'' --GD 3867
=v.
 
==
e, oo>
=_.
-2 m.
=>-n e
we.-
 
==
vs nun ne m ti i
t-e.-es esa ews woms is inesias av i, JX i
e e-e-es m
Auts arme s acams ope Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT mismus n sm==
=
UNIT 1
""* vs PUMP INSERVICE TESTING LOGP FOR
".E u.
av.
COMPONENT CDOLING VATER PUMP 1-1203-P4-004 N/A N/A ISI-D-212 I [F 1 2 1
e m
. m m
.<+--nww
+-w~+-.
.--w
+


l i
l i
MCB                                                                             PI                                                                       NOTES THIS IS A SIMPLIFIEld t HV                                 PI                                                                                                                                                                                                         HV            FI 1858                                    11803                                DIAGRAM USED TO DEPICT           ;
MCB PI HV NOTES THIS IS A SIMPLIFIEld t HV PI FI DIAGRAM USED TO DEPICT 1858 11803 11800 1878 1179 A TEST CIRCUIT. REFER LD TO THE P&ID FOR DETAILS. i LO
11800                               1878                                                                                                                                                                                                                     1179                     A TEST CIRCUIT. REFER
' 10.,
                                                                                                                                                                                                                                          ' 10. ,                                                                                                LD                                       TO THE P&ID FOR DETAILS. i LO
,q N
                                                                                          !            N
IM 16' 1-1203-P4-001 g4, i
                                                                                                                                                                                                                                                                                        ,q                                                               ,
16'                                                                                     IM                                                                        1-1203-P4-001                                                                                                                                         g4,                               i CMPNT. CLG.
OMC                                                                    VATER PUMP HV                                  PI                                        854                                                                                                                                                                            U 1879                                                                                                                                                                1860                                    11 4 11801                                                                                                                                                                                                                                                        1179 10'                                                                                                  LO LD                                                                                                                                                                                                                                                        '      i NN i       -
                                                                                                                                                                                                                                                                                        'N 16'                                                                                                                                                                                                                      032) 1                                                                          1-1203-P4-003                                                                                                                                                        ,
CMPNT. CLG.
CMPNT. CLG.
VATER PUMP                                                                                                                                           18'                               '
OMC VATER PUMP HV PI 854 U
QMC O                                                           HV                                 PI                                       856                                                                                                                   1862                                     11 5 1180                               1880                                                                                                                                                                                                                     1179 CCVS       1 LO
1860 11 4 1179 11801 1879 10' LO LD
                                                                                        '         '!,'                                                                                                                                 M                                            N'                                                               '                                   18'    -      COMPONENTS 16'                                                                                     1h                                                                          1-1203-P4-005                                  (034)
'N i
i N N 16' 032) 1 1-1203-P4-003 CMPNT. CLG.
VATER PUMP 18' QMC O
HV PI 856 1862 11 5 1180 1880 1179 CCVS 1
LO M
N' COMPONENTS 18' 1h (034) 16' 1-1203-P4-005 CMPNT. CLG.
VATER PUMP 20' (SPARE) 18' el li
_a_
i i
T LO HV 4'
COMPONENT CLG. VATER 11807 ge HEAT EXCHANGER 1-1203-a-001 COMPONENT CLG. VATER LO
*~
SURGE TANK HV f
1-1203-T4-001 11806 GlfL9) 1T 1866 - --
e s-e.-e.
 
==
wi num rar m t1 7-***
 
==
ews wmnets is is.suas sity s, JJC
"~"~
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT sosien n an
.mc UNIT 1
 
=== vs PUMP INSERVICE TESTING LOOP FOR "EC' m,
COMPONENT COOLING VATER PUMP 1-1203-P4-005 N/A N/A ISI-D-213 i (F 1 2
 
t S QMCB PI HV NOTE: THIS IS A SIMPLIFIED HV PI 1853 FI 1859 11811 DIAGRAM USED TD DEPICT 11808
! Gal 1179 A TEST CIRCUIT. REFER LD TO THE PLID FOR DETAILS.
10, e g
LO i
I',
h 16*
1-1203-P4-002 CMPNT. CLG.
g4, QMCB VATER PUMP HS l
pg HV HV PI FI 1861 11812 11797 11809 1882 10' LD LO c
lN:
l l
N 16' 1
1-1203-P4-004 (057)
CMPNT. CLG.
CMPNT. CLG.
VATER PUMP 20'                                                                                                                                                                                                       (SPARE)
VATER PUMP 18' QMC F1 PI HV 1179-HV PI 857 1863 11813 I I 11810 1883 18 CCVS l
_a_               18' el li  i    i T                             LO                                   ,
C MP NENTS LD A
4' HV                            '
.N.
COMPONENT CLG. VATER                                                                                       11807 ge' HEAT EXCHANGER COMPONENT CLG. VATER LO                                                                                                                                                                                                                                           1-1203-a-001
16' 1
                                                                                                                                                                                                                                                                                                  *~
1-1203-P4-006 (059) l CMPNT. CLG.
SURGE TANK                                                                                           HV GlfL9)      1 1-1203-T4-001                                                                                      11806 f
VATER PUMP 20' (SPARE) 18' iI I.
T 1866 - --
_a_
e         s-e.-e.  ==  wi    num rar m                                                                                                                   t1 7-***    ==  ews  wmnets is is.suas sity s,                                                                                                JJC
n T
      *                  "         "~"~                                                                                                                    "
LO HV 4'
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT                                                                         sosien n                              an    .mc UNIT 1                                              ""'                                === vs PUMP INSERVICE TESTING LOOP FOR COMPONENT COOLING VATER PUMP
jp COMPONENT CLG. VATER 11815 i
                                                                                                                                                                                                                                                                                                                                                                                          -.        "EC'              m, 1-1203-P4-005                                                        N/A                      N/A    ISI-D- 213        i (F 1 2
gi HEAT EXCHANGER COMPONENT CLG. VATER LO 1-1 03-M02 SURGE TANK HV l-1-1203-T4-002 11814 T
w a) 1-T L
1867
~
e s++
nu vs amanrm m ti a
ve-as os cws wantra su smessas av is JJC I
~
~
" ~ " " "
Southern Company Services. Inc.FOR Southern Nuclear Operating Company j
VDGTLE ELECTRIC GENERATING PLANT E8=<=
=
=c UNIT 1


t S QMCB                                                                                                                        PI PI                    1853                                                                                                                                                              HV                                                                          NOTE: THIS IS A SIMPLIFIED HV                                                                                                                                                              1859                  11811 FI              DIAGRAM USED TD DEPICT
=== vs PUMP INSERVICE TESTING LOOP FDR
* 11808    ! Gal                                                                                                                                                                                                                                                  1179              A TEST CIRCUIT. REFER LD                                                                                                  TO THE PLID FOR DETAILS.
" E h "
LO                                                                      i            10, e                                                                      g 16*        '  I',
.ex, men.
h                            1-1203-P4-002                                                                                                                                                                                                                  g4, CMPNT. CLG.
o COMPDNENT COOLING VATER PUMP 1-1203-P4-006 N/A N/A ISI-D-214 I (F 1 2 I
QMCB                            VATER PUMP HS                                                                                                                                                                                                                                                                            l pg HV        PI                                                                                                                                                                                    HV                                                              FI 1861                11812 1882 11809                                                                                                                                                                                                                                                            11797 10'                                                                                          LD LO                                                                    ;                                          c
                                                                                !  N lN:                l                  l 16'                                                                                                                                                                      (057) 1                            1-1203-P4-004                                                                                                                                                                                                                                    ,
CMPNT. CLG.
VATER PUMP                                                                                                                                                                                                                  18' QMC                                                                                                                                                                                                                                          F1 857                                                                                                                              PI                          HV                                                              1179-HV        PI                                                                                                                                                    1863                                                                                                      I I 1883                                                                                                                                                                      11813 11810                                                                                                                                                                                                                                                                                18 CCVS LD                                                                  A                                                                                        '
                                                                                                                                                                                                                                              .N.
l                                    C MP NENTS 16'                                                                                                                                                                      (059) 1                          1-1203-P4-006                                                                                                                                                                                                                                                        l CMPNT. CLG.                                                                                                                                                                                                                                                  !
VATER PUMP                                                                                                                                                                                                                                                      '
20'                                                                                              (SPARE)
_a_                                                            18' iI'        I.
n T                                                                    LO 4'                                                                                                                                                                                                                                                                                                                                                        HV                          ,
jp                                                                                                                                                                                          COMPONENT CLG. VATER                                                                                                        11815                        i gi                                                                                                                                                HEAT EXCHANGER COMPONENT CLG. VATER LO                                                                                                                                                                    1-1 03-M02 SURGE TANK                            HV                                                                                                                                            l-
* w a)                        1-1-1203-T4-002                        11814 T
T                                                                                                          ~
L                                                                                          1867 e              s++              nu            vs  amanrm m                                        ti a              ve-as os                        cws  wantra su smessas av is                        JJC I
    *              ~                ~                  " ~ " " "                                      "
Southern Company Services. Inc.FOR Southern Nuclear Operating Company                                                                                                                j VDGTLE ELECTRIC GENERATING PLANT                                                                                                    E8=<=    "                    =    =c              ,
UNIT 1                                                                                      ""                          === vs PUMP INSERVICE TESTING LOOP FDR COMPDNENT COOLING VATER PUMP men.        "Eh"         .ex, o 1-1203-P4-006                                                                                     N/A             N/A     ISI-D- 214   I (F 1 2   I


              . .            . -.  -  - . . . _ . - . . _ .  . - _ . __ . . . - . -            . = - . . -
. = -.. -
I I
I I
l l                                               SIPumps (1-1204-P6-003, & 004)
l l
G   System Function k.)                            -
SIPumps (1-1204-P6-003, & 004)
The SI system provides emergency core cooling and serves no other purpose.
G System Function The SI system provides emergency core cooling and serves k.)
no other purpose.
The primary function of the ECCS is to remove the stored and fission product decay heat from the reactor core following an accident in order to prevent fuel rod damage.
The primary function of the ECCS is to remove the stored and fission product decay heat from the reactor core following an accident in order to prevent fuel rod damage.
Quantity                           2 Type                             Horizontal, centrifugal,11-stage                                     i 4
Quantity 2
Manufacturer /Model               Pacific Model 3-i t., JHF                                           I Rated Capacity                     440 gpm                                                             I Rated Head                         2680 ft.                                                             :
Type Horizontal, centrifugal,11-stage i
Driver Type                         Electric Motor, Westinghouse, Frame 5809 H
4 Manufacturer /Model Pacific Model 3-i t., JHF I
;          Horsepower                   450 Speed                       3600 rpm l           Power Supply                 4160V,60 Hz,3 phase Code Class                         2 Project Class                     212 l     Outline Drawing                   IX6AG02-10,13 & 15 Instruction Book                   IX6AG02-016 Physical Location                 Aux Bldg, Level B, Rooms R-BIS & R-B19 P&ID                               1X4DB121 l     Surveillance Procedure             14804-1 Pump Test Loop Diagrams           ISI-D-215 & ISI-D-216 Test Parameter Sheets             Page 7-2 & 7-3 4
Rated Capacity 440 gpm Rated Head 2680 ft.
Driver Type Electric Motor, Westinghouse, Frame 5809 H Horsepower 450 Speed 3600 rpm l
Power Supply 4160V,60 Hz,3 phase Code Class 2
Project Class 212 l
Outline Drawing IX6AG02-10,13 & 15 Instruction Book IX6AG02-016 Physical Location Aux Bldg, Level B, Rooms R-BIS & R-B19 P&ID 1X4DB121 l
Surveillance Procedure 14804-1 Pump Test Loop Diagrams ISI-D-215 & ISI-D-216 Test Parameter Sheets Page 7-2 & 7-3 4
4 O
4 O
7-1                                     Rev.O I
7-1 Rev.O I
{
{
l
l


                                                                                                                                                                            \
\\
t Test Parameter Table - Pump 1-1204-P6-003 (Figure ISI-D-215)
t Test Parameter Table - Pump 1-1204-P6-003 (Figure ISI-D-215)
Instrumentation Utilized                       Ref.                                       Acceptable                                                         Alert         Action Parameter                                           Test Freq. I.D. No.(3)   Range         Rea. Ace.               Yalum                                       Range                                                               Range-       Range           Comments                             ;
Instrumentation Utilized Ref.
Speed                                                                                                                                                                                                                                                                                                   1 (N)                                                   NA       NA           NA           NA                       NA                                         NA                                                                 NA           NA               Constant speed driver Inlet Pressure                                           Qr         PI-0977       0-100           2%                     NA                                         NA                                                                   NA           NA               NA (Pi)                                                                         psig Outlet                                                                                                                                                                                                                                                                                                   ;
Acceptable Alert Action Parameter Test Freq.
Pressure                                             Qtr       Test         NA           12%                       NA                                         NA                                                                   NA           NA               NA                 i t                       (Po)                                                           Gage                                                                                                                                                                                                                                     j Differ.
I.D. No.(3)
                                                                                                                                                                                                                                                                          <.90 er >l.10APr NA Pressure                                             Qtr       NA(1)         NA           i ~. A                   APr                                       .90 - 1.10APr                                                       NA (AP)                                                                                                                                                                                                                                                                                                     ,
Range Rea. Ace.
Flowrate                                             Qtr       FI-0968       0-100       12%                       Qr                                         NA                                                                   NA           NA               Flowrate is set at reference value (Q)                                                                           gpm i
Yalum Range Range-Range Comments Speed 1
Vib.                                                                                                                                                                                                                                                                                                     ;
(N)
Amp.                                                 Qtr       (2)           NA           i5%                       Vr                                       s 2.5Vr                                                               > 2.5Vr - 6Vr >6Vr or         NA (V)(4)                                                                                                                                                         or >.325 in/s                                                       >.70 in/s Notes:                                                                                                                                                                                                                                                                                                   ;
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qr PI-0977 0-100 2%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr Test NA 12%
NA NA NA NA NA i
t (Po)
Gage j
Differ.
Pressure Qtr NA(1)
NA i ~. A APr
.90 - 1.10APr NA
<.90 er >l.10APr NA (AP)
Flowrate Qtr FI-0968 0-100 12%
Qr NA NA NA Flowrate is set at reference value
[
(Q) gpm i
Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                         ;
[
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                                                                                         i
: 2. Portable vibration instruments are utilized.
: 4. Measurements are taken in a plane approximately perpendicular to the routing shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                                                                                               ,
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
direction on each accessible thrust bearing housing.
i
i 7-2                                                                                                                                         Rev.O                                   ;
: 4. Measurements are taken in a plane approximately perpendicular to the routing shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
l t
[
i 7-2 Rev.O l
I t


O                                                                         O                                                                                                                                                                                             O Test Parameter Table - Pump 1-1204-P4-004 (Figure ISI-D-216)
O O
Instrumentation Utilized       Ref.     Acceptable                                           Alert           Action EaramticI                         Test Freq. I.D. NoJ3)   Range         Req. Acc. Value     Range                                                 Range           Range                                                                                             comments Speed (N)                               NA         NA           NA           NA       NA       NA                                                   NA               NA                                                                                               Constant speed driver             :
O Test Parameter Table - Pump 1-1204-P4-004 (Figure ISI-D-216)
Inlet Pressure                         Qtr       PI-0978       0-100         12%       NA       NA                                                   NA               NA                                                                                               NA (Pi)                                                       psig Outlet Pressure                         Qtr       Test         NA           12%       NA       NA                                                   NA               NA                                                                                               NA                 $              ;
Instrumentation Utilized Ref.
I (Po)                                         Gage Differ.
Acceptable Alert Action EaramticI Test Freq.
Pressure                         Qtr       NA(1)         NA           12%       APr       .90 - 1.10APr                                       NA               <.90 er >l.10APr NA (AP)
I.D. NoJ3)
Flowrate                         Qtr       FI-0968       0-100       12%       Qr       NA                                                   NA               NA                                                                                               Flowrate is set at reference value (Q)                                                       gpm Vib.
Range Req. Acc.
Amp.                             Qtr       (2)           NA           15%       Vr       5 2.5Vr                                             > 2.5Vr - 6Vr     >6Vr or                                                                                           NA (V)(4)                                                                                                                                           or >.325 in/s     >.70 in/s                                                                                                                           -
Value Range Range Range comments Speed (N)
t Notes:
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-0978 0-100 12%
NA NA NA NA NA 9
(Pi) psig l
Outlet Pressure Qtr Test NA 12%
NA NA NA NA NA I
(Po)
Gage Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er >l.10APr NA (AP)
Flowrate Qtr FI-0968 0-100 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA 15%
Vr 5 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s t
Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instmmentation other than that listed, which meets the requirements of the OM Code, may'be utilized for measuring test parameters.
: 3. At the discretion of SNC, instmmentation other than that listed, which meets the requirements of the OM Code, may'be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessi'i pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessi'i pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
7-3                                                                                                                                                                                 Rev.0
7-3 Rev.0
                                                                                                                                                                                                                                                                                ~+
~+


                                                                                                                                                                    /3                                                                                                                                 f3 d                                                                                                                                     V                                                                                                                                   V NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TD DEPICT                             M MCB                       HV FI A TEST CIRCUIT. REFER                                                                                                               0968 8964                       8964 TO THE P8.ID FOR DETAILS.
/3 f3 d
MMCB 3/4"                                                                                                                                                                                                                   REFUELING VATER G88                                                         HV j     l                                                                                                                           PCP STORAGE TANK 8813 th0
V V
                                                                                                                                                                                                                                                                                                -          ~
NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TD DEPICT M MCB FI HV 0968 A TEST CIRCUIT. REFER 8964 8964 TO THE P8.ID FOR DETAILS.
8813         M                                                                                                                                     HV l                    , ,                                                                            HV                                                                                         807 HV 802 q           FC           QMCB                                               1 1/2, 8814 HV                                                                                                                                                                                     >,
MMCB 3/4" REFUELING VATER G88 j l PCP HV STORAGE TANK th0
8888                                                                                                      g GMCD                                                                                                                                                                 ,
~
M                                                                                          MCB 7                                                                 3'                                             8814l                                                                                                                               CVCS CHARGING 802     k         k                           3/4,                                                                                         j 6,
8813 M
QM B                         807B                                                       ! PUMP QMCB             4'                                                                                                                                                                                                                                                   SUCTION HEADER 093)                                                       23                           HV HV                                                                                                                                           HS 821A m
8813 HV HV 807 l
HV               M   807B QMCB                                                                                                                                                   0998                   pg               923 00           (098)                                                                                                                                                   ,l                                                                          24" 0977                                   r' EI                                                           '                                                                                  '
HV q
                                                                                                                                                                                                          ,                              207 LO                                                                     1-1204-P6-003                       ~~
FC QMCB 1 1/2, 8814 802 HV g GMCD 8888 MCB 7
6'     >
3' M
SIS COLD 4*                                                                                                         SAFETY INJECTION                                                                                                                                                   HV LEG LDUP                                                                                                                                                                                                                                               L H                                             PUMP                                                                                                                                                   8806                     '
8814l CVCS CHARGING 802 k k
82 B                               MCB QMCB                                                                                                                                                           090                                                   M QMCB                                                                        094) 821B         M             PI                                                 8920 4                                                                                  MCB HV                                         QM B QMCB       HV 101 802                                                                   11/2*                                                                                     0978                                                                                                     g 4,
3/4, j
HS               r                         LO                                                                 1-1204-P6-004                                                       Dw k
QM B 807B
802                                                                                                                                                                        6, L                                                                          SAFETY INJECTION                                                                                                        (163)
! PUMP 6,
M                 RHRS DISCHARGE QMCB           4' 8                                                                        ,        l DM TRAIN *B' RHR HEAT EXCHANGER 3         9-ee-se ggig   VS_ IISKs FtR PST                                                                               I 7-e*-es em     ev. waarts = ines.m arv .                                                             ,       JC rE $ E             ."
QMCB 4'
* 7 . ".c "s
SUCTION HEADER 093) 23 HV HV HS 807B m
                                                                  ~~
821A HV M
                                                                                                                  $                                                  Southern Company Services. lnc. FOR Southern Nuclear Operating Company VDGTLE ELECTR                     ENERATING PLANT           =5"   "                                                        """  ''c PUMP INSERVICE TESTING LDDP                                                                 n.                         ". ~ 2             ,  =
QMCB 0998 923
FOR SAFETY INJECTION PUMP 1-1204-P6-003                           N/A                     N/A                               ISI-D- 215     1 [F 1 3
,l 24" pg 00 (098) 0977 r'
EI 207 LO 1-1204-P6-003
~~
6' SIS COLD 4*
SAFETY INJECTION L
HV LEG LDUP H
PUMP 8806 82 B MCB QMCB 090 M
094)
QMCB 8920 4 MCB 821B M
PI HV QM B QMCB HV 101 802 11/2*
0978 4,
g HS Dw r
LO 1-1204-P6-004 6,
(163) 802 k L
SAFETY INJECTION M
RHRS DISCHARGE QMCB 4'
l DM TRAIN *B' 8
RHR HEAT EXCHANGER 3
9-ee-se ggig VS_
IISKs FtR PST I
7-e*-es em ev.
waarts = ines.m arv.
, JC rE $ E
."
* 7. ".c "s Southern Company Services. lnc. FOR Southern Nuclear Operating Company
~~
VDGTLE ELECTR ENERATING PLANT =5"
''c PUMP INSERVICE TESTING LDDP n.
". ~ 2
=
FOR SAFETY INJECTION PUMP 1-1204-P6-003 N/A N/A ISI-D-215 1 [F 1 3


(~                                                                                                                       p                                                                                                                       /}
(~
O                                                                                                                         j NOTE: THIS IS A SIMPLIFIED                                                             "                                                                                                                                                                                                        I DIAGRAM USED TO DEPICT                                                     HS           HV A TEST CIRCUIT. REFER                                                     8964         8964                                             68 TO THE P&lD FDR DETAILS.
p
MCB                                                                                                                                                                                                                   _
/}
888                              3/I G           HV        i l                                                                                                     OM B                         PCP REFUELING VATLR STORAGE TANK 8813                                                                                                                 H                       TIS           1-204-T4 -001 807                     10980 8813     M                                                                                                                   '
O j
NOTE: THIS IS A SIMPLIFIED I
DIAGRAM USED TO DEPICT HS HV 68 A TEST CIRCUIT. REFER 8964 8964 TO THE P&lD FDR DETAILS.
MCB 3/I G i l REFUELING VATLR 888 HV OM B PCP STORAGE TANK 8813 H
TIS 1-204-T4 -001 807 10980 8813 M
HV
HV
                                      .                                                , r                                                       HV                                                                             EM                    807 802                                                  [           MCB                     1 1/2, 8814 8888 P                                                             3*                             M       8814
, r HV E
                                                                                                                                                                                                                                      ' QMCB 802                                                                                                                                                                                                                                      CVCS CHARGING L                                     3/4'                                                                                                             QM B                 807B                           H           PUMP 6'
807
QM B                 4'                                                                                                                                                                                                                                             "
[
093                                                       92 HS                                                                             80 B 82 A                                                                                                                                                                           HV             M QMCB                                                                                                                                             0998 H                                                   Q.00 '           (098) w 0977 pg                       A UM 923 I,I                                                            e4-821A       M                                                                                                                         i z
MCB 1 1/2, 8814 M
LO                                       1-1204-P6-003                           0-                                   D SIS COLD 4'                                         g                                                        SAFETY INJECTION 6'
802 8888
jl LEG LOOP                                                                                                                                                                                                                                           L         HV H           e                         PUMP LD                                        8806 HV                               0919                           8920 _                                                                                                                                                                                       QMCB QMCB     HV                                                                                                                                                           M                8806 821B -                                                                                 <->                                                  '
' QMCB P
HV                                         Q OMCB             HV                                                                                                                                                                                       b0 802                                              101 )
3*
1 1/2'                                                     !      0978                                                                                           H 4,              ,
M 8814 CVCS CHARGING 802 L
HS                 r                                   LO                                   1-1204-P6-004                               0:                                   D 802       k           L                                                                   SAFETY INJECTION PUMP 6,
3/4' QM B 807B H
                                                                                                                                                                                                                                      @                                      RHRS DISCHARGE QMCB                  4                                                                                                                                                                                              .
PUMP 6'
8                        /                             l FROM TRAIN *B' WV.                     9ME   BT   M's RHR HEAT EXCHANGER K-.m                       appq3   appg3         appeJ appte   a, pts Myuuurt e                       we= ma     vi             nuns run m                                                     tI a                       7-e* ==   . cvs             urams to es.sma uv is                                     -
QM B 4'
JJC rN   m" [es .Ev~., C.,7
093 92 HS 80 B 82 A HV M
                                                                                                ~ "
QMCB 0998 H
m5
Q.00 '
                                                                                                                            ~
(098) pg A
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT                             = 5==                   "                **wa           sac UNIT 1                   ',"*                  _              y , ,vs c
923 I
PUMP INSERVICE TESTING LOOP                                                             .        -,                          ,
e4-w 0977 UM I,
FOR SAFETY INJECTION PUMP 1-1204-P6-004                                 N/A                 N/A     ISI-D- 216                 1 [F 1 3
821A M
z i
LO 1-1204-P6-003 0-D SIS COLD 4' 6'
LEG LOOP g
SAFETY INJECTION jl L
HV H
e PUMP 8806 HV 0919 8920 _
LD QMCB QMCB M
HV 8806 821B -
HV Q
OMCB HV b0 101 )
802 1 1/2' 0978 4,
H HS r
LO 1-1204-P6-004 0:
D 802 k 6,
L SAFETY INJECTION QMCB 4
PUMP RHRS DISCHARGE
/
l FROM TRAIN *B' 8
RHR HEAT EXCHANGER WV.
9ME BT M's K-.m appq3 appg3 appeJ appte a, pts Myuuurt e
we=
ma vi nuns run m tI a
7-e*
 
==
. cvs urams to es.sma uv is
- JJC rN m" [es.Ev~., C.,7
~ "
~
m5 Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT = 5==
**wa sac UNIT 1 y,,vs c
PUMP INSERVICE TESTING LOOP FOR SAFETY INJECTION PUMP 1-1204-P6-004 N/A N/A ISI-D-216 1 [F 1 3


RHR Pumps j
RHR Pumps j
(1-1205-P6-001, & 002)                                         '
(1-1205-P6-001, & 002)
O U
O System Function U
System Function
The primary function is to remove heat energy from the i
                                                        ~          The primary function is to remove heat energy from the i
~
'                                                                  reactor core and reactor coolant system during plant -       !
reactor core and reactor coolant system during plant -
cooldown and ra4*hg operations. As a secondary               j function, RHR is used to transfer refueling water between the refueling water storage tank and the refueling cavity at the beginning and end of refueling operations.
cooldown and ra4*hg operations.
As a secondary j
function, RHR is used to transfer refueling water between the refueling water storage tank and the refueling cavity at the beginning and end of refueling operations.
Portions of the RHR system also serve as part of the ECCS during the injection and recirculation phsses of a LOCA.
Portions of the RHR system also serve as part of the ECCS during the injection and recirculation phsses of a LOCA.
Quantity                                             2 i
Quantity 2
Type Vertical, centrifugal, single stage
i Type Vertical, centrifugal, single stage Manufacturer / Mode!
!            Manufacturer / Mode!                               Ingersoll-Dresser,8X20WDF Rated Capacity                                     3000 gpm
Ingersoll-Dresser,8X20WDF Rated Capacity 3000 gpm
(-           Rated Head                                         375 ft.
(-
Driver                                                                                                           I Type O                Horsepower Speed Westinghouse LLD squirrel-cage induction motor 400 1780 rpm i
Rated Head 375 ft.
Power Supply                                 4160V,60 Hz,3 phase Code Class                                           2 Project Class                                       212
Driver I
}           Outline Drawing                                     AX6AF02-20007 l
Type Westinghouse LLD squirrel-cage induction motor O
Instruction Book                                     AX6AF02-20030 RHR Pumps (cont)
Horsepower 400 Speed 1780 rpm i
Physical Location                                   Aux Bldg, Level D, Rooms R-D48 & R-D49 P&ID                                                 1X4DB122
Power Supply 4160V,60 Hz,3 phase Code Class 2
(           Surveillance Procedure                               14805-1 & 14812-1
Project Class 212
: l.           Pump Test Loop Diagrams                             ISI-D-215 & ISI-D-216
}
,            Test Parameter Sheets                               Page 8-2 & 8-3 l
Outline Drawing AX6AF02-20007 l
l                                                                         81
Instruction Book AX6AF02-20030 RHR Pumps (cont)
;                                                                                                                  Rev.0 I
Physical Location Aux Bldg, Level D, Rooms R-D48 & R-D49 P&ID 1X4DB122
(
Surveillance Procedure 14805-1 & 14812-1 l.
Pump Test Loop Diagrams ISI-D-215 & ISI-D-216 Test Parameter Sheets Page 8-2 & 8-3 l
l 81 Rev.0 I


_ _ . . ~ . . . -         _ - _ _ - _ _ - _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ - _ - _ _                                                                                      . _ _ _ _ _ - - - _ - - _ _ _ _ _ - _ _ - - _ - - _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . . _ _ _ _                                                        _ _ _ _ _ _ _ _ - _ - _ .
_ _.. ~... -
C                                                                                                                                                                                       O                                                                                                                                               O                                         .
C O
f Test ParameterTable - Pump 1-1205-P6-001 (Figure ISI-D-217)                                                                                                                                                                                                         :
O f
Instrumentation Utilized                                   Ref.                                           Acceptable                                                                   Alert           Action                                                                       ,
Test ParameterTable - Pump 1-1205-P6-001 (Figure ISI-D-217)
Paramtitt                 Test Frea.                                     LDJio4) Range                                                             Rtg. Acc.           Value                                           B.ange                                                                       Range           Range           Comments t
Instrumentation Utilized Ref.
Speed (N)                       NA                                           NA                                           NA                           NA                   NA                                             NA                                                                             NA             NA               Constant speed driver Inlet Pressure                   Qtr                                           PI-8884                                     0-100                         12%                 NA                                             NA                                                                             NA             NA               NA                                                           I (Pi)                                                                                                                 psig Outlet                                                                                                                                                                                                                                                                                                                                                                                               .
Acceptable Alert Action Paramtitt Test Frea.
Pressure                   Qtr                                           PI-8886                                     0-400                         12%                 NA                                             NA                                                                             NA             NA               NA                 ,
LDJio4)
(Po)                                                                                                                 psig Differ.
Range Rtg. Acc.
Pressure                   Qtr                                         NA(1)                                         NA                             2%                 APr                                           .90 - 1.10. ipr                                                               NA             <.90 or >1.10APr NA                                                           ;
Value B.ange Range Range Comments t
i (AP) i Flowrate                   Qtr                                         FI-0618A                                     0-5000                       12%                 Qr                                           NA                                                                             NA             NA               Flowrate is set at reference value                           I (Q)                                                                                                                   gpm Vib.                                                                                                                                                                                                                                                                                                                                                                                                 ;
Speed (N)
Amp.                       Qtr                                       (2)                                           NA                             15%                 Vr                                           s 2.5Vr                                                                         > 2.5Vr - 6Vr   >6Vr or         NA                                                           ;
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-8884 0-100 12%
(V)(4)                                                                                                                                                                                                                                                                                                 or >.325 in/s   >.70 in/s                                                                     i Notes:
NA NA NA NA NA I
(Pi) psig Outlet Pressure Qtr PI-8886 0-400 12%
NA NA NA NA NA
(
(Po) psig Differ.
Pressure Qtr NA(1)
NA 2%
APr
.90 - 1.10. ipr NA
<.90 or >1.10APr NA (AP) i-i Flowrate Qtr FI-0618A 0-5000 12%
Qr NA NA NA Flowrate is set at reference value I
(Q) gpm l
Vib.
Amp.
Qtr (2)
NA 15%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s i
Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thmst bearing housing.
L
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial
{
direction on each accessible thmst bearing housing.
i t
i t
8-2                                                                                                                                         -
8-2 Rev.0 j
Rev.0                                                           j
[
[
_ . . _ _ . . . _ _ _ _    _.._____.____m___      , _ _ _ _ _ _ . _ _ _ . _ _                                                                                                                .. -  _          _.                              -          , , , , , ,
m


J                                                                                                                                 O                                                                                                                                                                                                           O ,
J O
Test ParameterTable - Pump 1-1205-P6-002 (Figure ISI-D-216)                                                                                                                                                                                                   !
O Test ParameterTable - Pump 1-1205-P6-002 l
Instrumentation Utilized         Ref.       Acceptable                                                                     Alert                   Action
(Figure ISI-D-216)
* Earamtitr           Test Freq.                               I.D. No.(3)                                           Range     Reg. Acc. Yalut     Range                                                                           Rangt                   Range                                                       Comments Speed (N)                 NA                                     NA                                                     NA       NA         NA       NA                                                                               NA                       NA                                                         Constant speed driver inlet Pressure           Qtr                                     PlfS885                                                 0-100   12%         NA       NA                                                                               NA                       NA                                                         NA                                     j (Pi)                                                                                                                 psig Outlet Pressure             Qtr                                     PI-8887                                                 0-400   12%         NA       NA                                                                               NA                       NA                                                         NA                                   ,
Instrumentation Utilized Ref.
(Po)                                                                                                                 psig                                                                                                                                                                                                                                         .
Acceptable Alert Action Earamtitr Test Freq.
Differ.
I.D. No.(3)
Pressure             Qtr                                   NA(1)                                                   NA       12%       ' APr       .90 - 1.10APr                                                                   NA                       <.90 or > t.10APr NA (AP)                                                                                                                                                                                                                                                                                                                                                             t Flowrate             Qtr                                   FI-0619A                                                 0-5000   i2%         Qr       NA                                                                             NA                       NA                                                         Flowrate is set at reference value (Q)                                                                                                                 gpm                                                                                                                                                           x Vib.
Range Reg. Acc.
A m p.-             Qtr                                   (2)                                                       NA       i5%         Vr       s 2.5Vr                                                                       > 2.5Vr - 6Vr             >6Vr or                                                     NA (V)(4)                                                                                                                                                                                                                             or >.325 in/s             >.70 in/s Notes:
Yalut Range Rangt Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PlfS885 0-100 12%
NA NA NA NA NA j
(Pi) psig Outlet Pressure Qtr PI-8887 0-400 12%
NA NA NA NA NA (Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
' APr
.90 - 1.10APr NA
<.90 or > t.10APr NA (AP) t Flowrate Qtr FI-0619A 0-5000 i2%
Qr NA NA NA Flowrate is set at reference value (Q) gpm x
l Vib.
A m p.-
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
I
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                                                                   ;
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
[
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
f 8-3                                                                                                                                                                                                   Rev.0 i
f 8-3 Rev.0 i
i i
i.
i


p                                                                                                                                 Q                                                                                                                                                         f V                                                                                                                                 (>                                                                                                                                                       U)
p Q
NOTE: THIS IS A SlHPLIFIED                                               FI               FIC                                                                                                                                                 FROM CONTAINMENT FV                                                                                      3, DIAGRAM USED TO DEPICT                                               618             0618                                                                                                                                                                 EMERGENi '' SUMP O                             dR                       ILS. OMC               00                                                                             M061 PI                     OMCE                                                                                   _                                                    _
U) f V
HV                                         FT 0618           HV 0606
(>
                                                                                                                                          ^
NOTE: THIS IS A SlHPLIFIED FI FIC FROM CONTAINMENT DIAGRAM USED TO DEPICT 618 0618 FV 3,
8886 M                                                                              HV 8811 REFUELING VATER 0620                                                                                          STORAGE TANK 809 M                                   0618                                                                                                                               PI l                                       (019 0612                                                                                                                                                   l-1204-T4-001 SIS COLD LEG 8'           :,:            - llr0ll                      '
EMERGENi '' SUMP O
N---{- Q
dR ILS. OMC 00 M PI OMCE 061 8886 M HV REFUELING VATER 0618 HV
                                                                                                    <l,            2,,      1-1205-E6-001 LOOP                                               8'                                                                                                                 @l)                                         Ji 14 HV                                                                                                                                       FIS M                           PI 804                                                             FY T                                                                                                                QMCB L                                                                              0610                   5016     8884 g,                                                H     (12 2 )               g                               g CVCS CHARGING = 7 4                                                                           . 0618         CVCS LETDOVN                                                   1-1205-P6-001                                                                                                       812y PUMP SUCTION -                                                                                           HEAT EXCHANGER                                                 RESIDUAL HEAT                                                 1 r                                                                       HV HEADER                                                                                                       se REMOVAL PUMP                                                   J L                                                                       812 -
^
M HV                                 HV                         Ml 15                                  8'                                       LC,             LC 840                                 716                                                                                                       ,m ,
HV FT 0606 0620 8811 STORAGE TANK 809 M 0618 l
m, r,
(019 0612 PI l-1204-T4-001 SIS 8'
RCh0W1                                      i RHT(027)                                 (226)         -9                                  :      12' 24' FV                         3 RCS                       '
- ll ll N---{-Q COLD LEG
                                      - "'                                                                        0611 HOT LEG                                           HV                                                                             OMCBM PI                                                QMCB M 0615 8887                                             M LOOP
<l r0 1-1205-E6-001 LOOP 8'
                                                                                                                                                                                                                                                                                                                                            ~~
2,,
m 716 HV                                                               HV 0607                                                                                                (0621,1 809 M                               r                                                                   (020 0613                                                   Y           06 2                                                       02 s'                                                                                                                '                                                                                          QM SIS COLD LEG
@l)
:.-              llhl                                                  '3                   M               {                                                         12-                     L                 RCS HOT LEG 2'
J i
l-1205-E6-002                                                                 '                                                                          "'
14 HV FIS M T
LOOP 4 LOOP                                                           FT                                                                                                   (010 )                                                   o 8'
PI QMCB 804 L
QMcB 0619                                       @                                                      FIS M                             PI                             Q
FY 0610 5016 8884 H
                                                                                                                                                                                                                                                      "-                                                                      QMCB HV b                 '
(12 2 )
7 0619 7'
g, g
0611     5015         5017       8885                                       HV                                                 H 0619 LOO                        Iv                                                                                                                                   34'   88llB                                             812 804                                                                  0619         CVCS LETDOVN 0619                  $                                                                                    l-1205-P6-00 HEAT EXCHANGER RESIDUAL HEAT 1 F               ^                    (00p'                           HV SIS SAFETY                      _ ''
g CVCS CHARGING = 7 4
a                                                                                                                                                                                    j c-1M)                                                       M       8812 INJECTION                                                                           !I   I                                                                               REMOVAL PUMP                                 FRDi CONTAINMENT 619                         FC s,
. 0618 CVCS LETDOVN 1-1205-P6-001 812y PUMP SUCTION -
PUMP SUCTION                                                                                                                                                                                                                           EMERGENCY SUMP, j MCB                                                                                                                                                                         12'                                 V i SEv. Om Tt       DT       Oer1                                     stSt EPTEM                       apres   asww2   mPPR.3 araw .           erwetS           apuers
HEAT EXCHANGER RESIDUAL HEAT 1 r HV HEADER Ml 15 se REMOVAL PUMP J L M
                .        ..          -            v,                     .,                                                    1 i       v-e.-es     as           cve             winer to imour scv i,                                       JC
812 -
                                                                                                                            -k[ "
HV HV 8'
                ',       ',~. l     c5               s          Cl 'l *[                                                                                                             Southern Company Services, Inc.FOR Southern Nuclear Operating Company os
LC, LC 840 716
                                                                  ^sr )'t      s MB                                                         VDGTLE ELECTR                 ENERATING PLANT 'r= ' "                                                                       ,"v"               '"c
,m,
                .        w-r -=. m                           en aw= m acam                                           Av5                                                                                                                                                   ,mc   ,                        -.,,,,,u, PUMP INSERVICE TESTING LOOP                                                                             ,.ui.m                 se             t.       no           .s v. ,
RCh0W1 m,
FOR RESIDUAL HEAT REMOVAL PUMP l-1205-P6-001                                                             N/A             N/A       ISI-D- 217                       1 OF 1           6
i r,
- 9 12' 24' RHT(027)
(226)
FV 3
RCS 0611 OMCBM PI QMCB HOT LEG HV 0615 8887 M
~~
LOOP 716 m
HV HV M
(0621,1 0607 809 M r
(020 0613 Y
06 2 02 QM llhl
'3 M
{
SIS s'
12-L RCS HOT LEG COLD LEG l-1205-E6-002 LOOP 4 LOOP FT 2'
(010 )
o Q
8' QMcB 0619 FIS M PI 7'
QMCB b
7 0619 0611 5015 5017 8885 HV H
HV 0619 Iv 34' 88llB 804 LOO 812 0619 0619 CVCS LETDOVN l-1205-P6-00 HEAT EXCHANGER 1 F (00p' HV
^
RESIDUAL HEAT j c-1M) 8812 SIS SAFETY a
M INJECTION
!I I
REMOVAL PUMP FRDi CONTAINMENT 619 s,
PUMP SUCTION FC EMERGENCY SUMP, j
MCB 12' V i SEv.
Om Tt DT Oer1 stSt EPTEM apres asww2 mPPR.3 araw.
erwetS apuers v,
1 JC i
v-e.-es as cve winer to imour scv i,
-k[
Southern Company Services, Inc.FOR Southern Nuclear Operating Company
',~. l c5 Cl 'l *[
s
^ )'
MB VDGTLE ELECTR ENERATING PLANT 'r= ' "
'"c
,"v" sr t s
os w-r -=.
m en aw= m acam Av5
,mc
-.,,,,,u, PUMP INSERVICE TESTING LOOP
,.ui.m se t.
no
.s v.
FOR RESIDUAL HEAT REMOVAL PUMP l-1205-P6-001 N/A N/A ISI-D-217 1 OF 1 6


O                                                                                                                                               O                                                                                                                                                                     O NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT
O O
[M0618Al M          FV                                                       3,                                                           FROM CONTAINMENT QMC                                                  0618                                                                                                                                  EMERGENCY SUMP A TEST CIRCUIT. REFER                                                                                                         0610 TO THE PLID FOR DETAILS.                                                                                         00                                         DMCB M pt                         OMCB                                                                             _                                                                    _
O NOTE: THIS IS A SIMPLIFIED
0618           HV                 ^                0614 8886               HS                                                                 HV HV                                                                                                                                                                                                                                                               REFUELING VATER FT                       0606                                                         0620                                                               8 811 809                                                                                                                                                                                                                                                                          STORAGE TANK M                                                             0618                                                     (019 0612 l                                                                                                                0601                                                           1-1204-T4-001 0                                 '
[M M
SIS COLD LEG LOOP B*
FROM CONTAINMENT DIAGRAM USED TO DEPICT 0618Al 0618 FV 3,
8, hl lik e
EMERGENCY SUMP A TEST CIRCUIT. REFER QMC 0610 TO THE PLID FOR DETAILS.
FO      2, r
00 DMCB M pt OMCB 0618 HV 0614 8886 HS HV REFUELING VATER
1-1205-E6-001 g{
^
i
HV FT 0606 0620 8 811 STORAGE TANK 809 M
(]ED
0618 l
                                                                                                                                                                                                            *}                                          H                     ,
(019 0612 0601 1-1204-T4-001 lik 0
HV                                                                                            !                  N                               FI       Q           TI                                     PI                                                                                   OMCB 0618                                                                                                     8884        34, py                                                                                                                    870 A 812                                    V CVCS CHARGING = r 4                                                 '                                                          0618       CVCS LETDOVN                         1-1205-P6-001 PUMP SUCTION                         7
SIS B*
                                                                                                                                        'I HEAT EXCHANGER                         RESIDUAL HEAT                                                     1                                                             T                         HV HEADER                                                                                                                                                     4                                                                                            M
g{
                                                                                                                                            ,                8'                               REMOVAL PUMP                                                       J L                                                           g                     812 HV                   HV                                                                             M li                             g,             mLC,             ,LC 8840                                                                                                                                                   r,               r, RCS    O h Tl LEG                i *
*}
                                                                                                                                                                                                                                      -g                     "
r i
FV                 3' RCS         -
COLD LEG hl FO 1-1205-E6-001 LOOP 8,
0611                                                                                                                                         (001 )
2,
HOT LEG                          HV                                                                                                                        OMCB M pg                       OMCB                                                   1 LDDP                           716                                                                                                             ^                 0615 8887          M                                                                                                                                                  '
(]ED H
809 M                r                                                                                    06 7                                         l                                                           PI                       HV (020                                                                         0602                       702         M w                                                                                     12'                                           ES "
e N
COL LEG                                                                                                       o                          1-12           2                                                                                                         r4 LOOP                                                                                           FT                               2'                                                                                                   'e                                                                              LOOP 4 (010 )                                                   '
FI Q
8' OMCB 0619                                                                                                                 flS FV Q             ]                                   PI           _                                                                    OMCB HV                     O 9                                                                                 FV                                                                                                                   881 B 804                                                                                   O g
TI PI OMCB HV 8884 0618 34, 870 A py CVCS CHARGING = r 4 0618 CVCS LETDOVN 1-1205-P6-001 812 V
j            0619 CVCS LETDOVN                                                                                                                                                                                 k
'I PUMP SUCTION 7
                                                                                                    '                                                  HEAT EXCHANGER                                                                                         1   rj g                    (,00.
HEAT EXCHANGER RESIDUAL HEAT 1
0 U                                                    HV SIS SAFETY                                                                                                                                                   u
T HV HEADER M
                                      =
8' 4
l-1205-P6-002                                                     ; L v M                     812 INJECTION                                           619                                                            I I                   e.                              RESIDUAL HEAT                                                 FRDi CONTAINMENT PUMP SUCTION                                                                                                           FC                                                   REMOVAL PUMP                                                   EMERGENCY SUMP, j MCB                                                                                                                                                         -
REMOVAL PUMP J L g
12'                  ' '
812 HV HV M li g,
          .cy         it       ,,  cm3                                                                               scsc.,,rs>.                     -4   -2     =>   m.   -s     awers F       9-94-9. SEE   Ws     II3tK9 FIBt PET                                           _
LC,
                                                                                                                                                        *I v- e+es   me     cvs   wn.it in u. sour stv n                                                                                     JC
,LC RCS h T LEG m
                    ,    ,  ",l
O l
                                      ,,    [ 'l*l       ,                    '[!                                                                   [                               Southern Company Services, Inc.FOR Southern Nuclear Operating Company
8840 i
                    ')                                                         Et s
* r, r,
                        .-    m s    s      st it
- g FV 3'
                                            . .                      ..m                                                                          e B                              V0GTLE ELECTR C ENERATING PLANT                                                       'E5"'       "
RCS 0611 (001 )
y                             ""c PUMP INSERVICE TESTING LOOP
OMCB M pg OMCB 1
                                                                                                                                                                                                      ^       ^
HOT LEG HV 0615 8887 M LDDP 716
                                                                                                                                                                                                      -120 -P6-002                                                             N/A           N/A                     ISI-D- 218                               1 DF l     6
^
06 7 l
PI HV 809 M r
(020 0602 702 M
w 12' ES "
COL LEG 1-12 2
r4 o
LOOP 4 LOOP FT 2'
(010 )
' 'e 8' OMCB 0619 flS FV Q
]
PI OMCB HV O 9 FV 881 B 804 O
j g
0619 CVCS LETDOVN k
HEAT EXCHANGER 1
(,00. U HV r
0 j
g SIS SAFETY u
l-1205-P6-002
; L v 812
=
M INJECTION I I RESIDUAL HEAT FRDi CONTAINMENT 619 e.
PUMP SUCTION FC REMOVAL PUMP EMERGENCY SUMP, j
MCB 12'
.cy it cm3 scsc.,,rs>.
-4
-2
=>
m.
-s awers F
9-94-9.
SEE Ws II3tK9 FIBt PET
*I v-e+es me cvs wn.it in u. sour stv n JC
",l
[ 'l*l '[!
[
Southern Company Services, Inc.FOR Southern Nuclear Operating Company
')
Et B
V0GTLE ELECTR C ENERATING PLANT 'E5"'
y
""c s
s s
st it m
..m e
PUMP INSERVICE TESTING LOOP
^
^
-120 -P6-002 N/A N/A ISI-D-218 1 DF l 6


  ~   _ _ _ _ . - . _ _ .                . _ . - _ . _ _ _ . _ . _ . . _ _ - _ . _ _ . _ . _ _ . _ _ . _                              . - . _ . . . _    .
~
l CS Pumps                                                               l (1-1206-P6-001, & 002)'                                                           ;
l CS Pumps (1-1206-P6-001, & 002)'
j System Function                                         Containment spray limits the peak pressure in the                             l
j System Function Containment spray limits the peak pressure in the containment to less than design pressure following a LOCA
                                                                      ~
~
containment to less than design pressure following a LOCA                     1 or a main steam line break inside containment. Trisodium                       !
or a main steam line break inside containment. Trisodium phosphate is mixed with recirculated spray water in the containment sump region for pH control and to enhance absorption of the airborne fission product iodine and to retain the iodine in the containment sump solution to limit calculated offsite doses to less than 10CFR100 limits.
phosphate is mixed with recirculated spray water in the containment sump region for pH control and to enhance absorption of the airborne fission product iodine and to retain the iodine in the containment sump solution to limit calculated offsite doses to less than 10CFR100 limits.
Quantity 2
Quantity                                                 2                                                                             i Type                                                     Horizontal, centrifugal                                                       j Manufacturer /Model                                     Goulds Model 3415                                                           ..
i Type Horizontal, centrifugal j
Capacity                                               2600 gpm-l                                                                                                                                                               l l                      Total Dynamic Head                                       450 ft.
Manufacturer /Model Goulds Model 3415 Capacity 2600 gpm-l l
Total Dynamic Head 450 ft.
l
l
                      ' Driver                                                                                                                                 l Type                                             Westinghouse electric motor, Frame 5010S                                     ,
' Driver Type Westinghouse electric motor, Frame 5010S Horsepower 400 Speed 1777 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2
Horsepower                                       400                                                                           l Speed                                             1777 rpm Power Supply                                     4160V,60 Hz,3 phase                                                           ;
l Project Class 212 Outline Drawing IX6AD02-11 l-Instruction Book X6AD02-18 i
Code Class                                               2 l
l l
Project Class                                           212 Outline Drawing                                         IX6AD02-11 l-                       Instruction Book                               ,
Physical Location Aux Bldg, Level D, Rooms R-D76 & R-D77 j
X6AD02-18 i                                                                                                                                                               l l                         Physical Location                                       Aux Bldg, Level D, Rooms R-D76 & R-D77                                       j P&ID                                                     IX4DB131 Surveillance Procedure                                   14806-1 Pump Test Loop Diagrams                               . ISI-D-219 & ISI-D-220 Test Parameter Sheets                                   Page 9-2 & 9-3 lO 9-1                             Fev. 0
P&ID IX4DB131 Surveillance Procedure 14806-1 Pump Test Loop Diagrams
. ISI-D-219 & ISI-D-220 Test Parameter Sheets Page 9-2 & 9-3 lO 9-1 Fev. 0


Test Parameter Table - Pump 1-1206-P6-001                                                                                                                                                                                                                                                                     ,
Test Parameter Table - Pump 1-1206-P6-001 (Figure ISI-D-219)
(Figure ISI-D-219)
Instrumentation Utilized Ref.
Instrumentation Utilized                                                                 Ref.                                                 Acceptable                                   Alert                                                         Action Parameter           Test Freu,                                 J.D. No.(3)   Range                         Req. Acc. Yalue                                                                                         Range                                       Range                                                         Range                                 Comments Speed                                                                                                                                                                                                                                                                                                                                                                                                             ,
Acceptable Alert Action Parameter Test Freu, J.D. No.(3)
(N)                 NA                                         NA           NA                           NA                                                 NA                                                   NA                                         NA                                                             NA                                   Constant speed driver                         i Inlet Pressure           Qtr                                       PI-0972       0-100                       12%                                                 NA                                                   NA                                         NA                                                             NA                                   NA (Pi)                                                                         psig Outlet Pressure           Qtr                                       PI-0974       0-300                       12%                                                 NA                                                   NA                                         NA                                                             NA                                   NA                   i (Po)                                                                         psig Differ.
Range Req. Acc. Yalue Range Range Range Comments Speed (N)
Pressure           Qtr                                       NA(t)         NA                           12%                                               APr                                                   .90 - l .10APr                             NA                                                             <.90 er >l.10APr NA (AP)
NA NA NA NA NA NA NA NA Constant speed driver i
Flowrate           Qtr                                       F1-0929       0-400                       12%                                               Qr                                                   NA                                         NA                                                             NA                                   Flowrate is set at reference value           t (Q)                                                                         gpm Vib.                                                                                                                                                                                                                                                                                                                                                                                                             [
Inlet Pressure Qtr PI-0972 0-100 12%
Amp.               Qtr                                       (2)         NA                           i5%                                                 Vr                                                   s 2.5Vr                                   > 2.5Vr- 6Vr                                                     >6Vr or                               NA (V)(4)                                                                                                                                                                                                                                                       or >.325 in/s                                                   >.70 in/s Notes:
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-0974 0-300 12%
: 1. Differential pressure is calculated as, AP = Po - Pi                                                                                                                                                                                                                                                                                                                                                         ;
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(t)
NA 12%
APr
.90 - l.10APr NA
<.90 er >l.10APr NA (AP)
Flowrate Qtr F1-0929 0-400 12%
Qr NA NA NA Flowrate is set at reference value t
(Q) gpm Vib.
[
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr-6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
t
t
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
9-2                                                                                                                                                                                             Rev.0 l
9-2 Rev.0 l
_ . _ _ . _ _ _ _ . _ _ _ _ _  --          ~ . . _ _ . _ _ _ _ _ _ . . , . . _ _ _ _ . _ _ . _ _ _ _ _ _ _ _ _ _ _ . - . _ _ _ . _ . _ .           ___m__ _ _ . _ ____..a.____        ___________m
~.. _ _. _ _ _ _ _ _..,.. _ _ _ _. _ _. _ _ _ _ _ _ _ _ _ _ _. -. _ _ _. _. _.
m
..a.
m


O                                                                                                                                                       O                                                                                                                     O Test Parameter Table - Pump 1-1206-P6-002 (Figure ISI-D-220)
O O
Instrumentation Utilized                                       Ref.                       Acceptable         Alert               Action Entameter                               Irst Frey.                                     I.D. No.(3)   Range                                       Req. Acc. Yalue                       Range               Range               Range                                                   Commeuts Speed (N)                                       NA                                           NA           NA                                         NA       NA                         NA                 NA                 NA                                                     Constant speed driver Inlet Pressure                                 Qtr                                           PI-0973       0-100                                     12%       NA                         NA                 NA                 NA                                                     NA (Pi)                                                                                                 psig Outlet Pressure                                 Qtr                                           PI-0975       0-300                                     i2%       NA                         NA                 NA                 NA                                                     NA                 .
O Test Parameter Table - Pump 1-1206-P6-002 (Figure ISI-D-220)
(Po)                                                                                                 psig Differ.
Instrumentation Utilized Ref.
Pressu e                                 Qtr                                           NA(1)         NA                                         i2%       APr                         .90 - 1.10APr       NA                 < 90 or >l.10APr NA (AP)
Acceptable Alert Action Entameter Irst Frey.
Flowrate                                 Qtr                                           F1-0929       0-400                                         2%     Qr                         NA                 NA                 NA                                                   Flowrate is set at reference value (Q)                                                                                                   gpr t Vib.
I.D. No.(3)
Amp.                                     Qtr                                           (2)           NA                                         i5%       Vr                         s 2.5Vr             > 2.5Vr- 6Vr       >6Vr or                                             NA (V)(4)                                                                                                                                                                                                     or >.325 in/s       >.70 in/s Notes:
Range Req. Acc. Yalue Range Range Range Commeuts Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-0973 0-100 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-0975 0-300 i2%
NA NA NA NA NA (Po) psig Differ.
Pressu e Qtr NA(1)
NA i2%
APr
.90 - 1.10APr NA
< 90 or >l.10APr NA (AP)
Flowrate Qtr F1-0929 0-400 2%
Qr NA NA NA Flowrate is set at reference value (Q) gpr t Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr-6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shall in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shall in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
9-3                                                                                                         Rev.O
9-3 Rev.O


O                                                                                                                                                                                                                                                                                         O
O O
                                                                                                                                                                                                                                                                                                                                                                                                                                                                  %)
%)
NOTE: THIS IS A SIMPLIFIED                                                                                                                                                                                                                                                                                   ,LC,                             p, DIAGRAM USED TO DEPICT                                                                                                                                                                                                                                                                                       r,                                                                                                                                                 _
NOTE: THIS IS A SIMPLIFIED
A TEST CIRCUIT. REFER                                                                                                                                                                                                                                                                                   (006)
,LC, p,
TO THE P&ID FOR DETAILS.                                                                                                                                                                                                                                                                                                                                                                     HV 9003 QMCB                                                                                                                                                                                                                                                       QMC'B 9001                                                                                                                                                                                                                                           HS                                                                                                                                                                                                       2' HV                                                                                                                                                                                                                                                                                                                                                  mr       FROM CONTAINMENT TI                                         PI                                                                                                 1094                                                                                                           "'
DIAGRAM USED TO DEPICT r,
9001A                                                                       0938 0974                                                                                                                                                                                                                         PI                       12'                     ENERGENCY SUMP                                       FI               __
A TEST CIRCUIT. REFER (006)
TO               M                                                                                                                                                                                                                                               ,                                                              0972                                                                                                       929                    -
TO THE P&ID FOR DETAILS.
CONTAINMENT - ? ,
HV 9003 QMCB QMC'B 9001 HS 2'
SPRAY                             8, I
mr FROM CONTAINMENT HV TI PI 1094 9001A 0938 0974 PI 12' ENERGENCY SUMP FI 929 TO M
0972 CONTAINMENT - ?,
I
] 12' SPRAY 8,
l
l
                                                                                                                                                                                                                                                                                        ] 12'                                                                                                                                                                                                -n p
-n p
a                                                                                                                                               CONTAINMENT SPRAY                                                                                 g J                                                                                                                                                                                                                                                                                                                                      --C PUMP                                                                       S CONTAINMEN                                                                                                                                                                                                                                                                                                                                                               '
a CONTAINMENT SPRAY J
SPRAY EDUCTOR
g
                                                                                                                                                                                                              "                                                                    SPRAY ADDITIVE TANK                                                                                                 M    9017A 1-1206-J6-001                                                                                                             $                                                                                    g U                                                                                                           HV                                                       HV                                         90   A.
--C PUMP S
                                                                                                                                                                                  "                                                                             3*                                                          3'                                                                                                                          .
CONTAINMEN SPRAY ADDITIVE SPRAY EDUCTOR M
                                                                                                                                                                                                    -S                                                                                       994                                                     994 REFUELING VATER                                 c 3                                                                                                                               MCB                                                         MCB STORAGE TANK o                          h S
9017A TANK 1-1206-J6-001 g
3' ] %                                     994                               )%                       9[4                       2         09               1-1204-M-001 CONTAINMENT SPRAY EDUCTOR k                                                                                                                                               1,C,                                     HV
U 3*
                                                                                                                                                                                                            "                                                                                                                                                                              10     9017B 1-1206-J6-002                                                                                                                                                                                                                                                                   15 2                                               MCB 9001B 3'                                                         ,QMCB HV                                                                                                                 e                                                                                                                                                                                                                           M      9017B 4
HV 3'
D TO h 9001B m m                  8' 0 9
HV 90 A.
[C                                                                                                                                                              0973 PI
" -S 994 994 REFUELING VATER c
                                                                                                                                                                                                                                                                                                                                                                                              ,5 G
3 MCB MCB STORAGE TANK h
o             HV 9003P CONTAINMENT SPRAY 7'
3' ] % 994
e-         2' 1-1206-P6-002 h
)% 9[4 2
PI                                                                                                                                                                                                                                                        l              m -          FROM CONTAINMENT CUNTAINMENT SPRAY                                                                           12-         r, 0975                                                                                                                                                                                                                                                                                                EMERGENCY SUMP PUMP ES                               2*
09 1-1204-M-001 o
s.,     -    -,
S CONTAINMENT k
dT6h
1,C, HV SPRAY EDUCTOR 10 9017B 1-1206-J6-002 15 2 MCB 9001B 3'
            .    . s-e-   an     vs     nacs em es,                                                                                                                                                                                                     i e     F-em   ==     cve     won,ts a trema av rs                                                                                                                                                                             -       _iC a       +am-e, nos     vs     weares a n. ems av r,                                                                                                                                                                           -cC s     m-,. m     m       usuv m .caso                                                                                                                                                                                   m                                                                                               Southern Company Services, inco rOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT                                   E 5'***                                 ""*"
,QMCB M
UNIT I                     '"''                              " ' ' * ' vs sc=1   .s,.                     a=rsus e. san PUMP INSERVICE TESTING LODP                                               a.                     s,.wa.                                       x, u FOR CONTAINMENT SPRAY PUMP 1-1206-P6-001                     N/A       N/A               ISI-D- 219                                     1 [F 1 3
9017B HV e
h 9001B
[CD 4
PI G
0 9 0973 o
HV TO 8'
,5 9003P m
m 7'
2' h
CONTAINMENT e-SPRAY 1-1206-P6-002 l
FROM CONTAINMENT PI CUNTAINMENT SPRAY m -
12-r, EMERGENCY SUMP 0975 PUMP ES 2*
dT6h s.,
. s-e-an vs nacs em es, i
e F-em
 
==
cve won,ts a trema av rs
- _iC a
+am-e, nos vs weares a n. ems av r,
-cC s
m-,.
m m
usuv m.caso m
Southern Company Services, inco rOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT E 5'***
UNIT I
" ' ' * ' vs sc=1
.s,.
a=rsus e. san PUMP INSERVICE TESTING LODP a.
s,.wa.
x, u
FOR CONTAINMENT SPRAY PUMP 1-1206-P6-001 N/A N/A ISI-D-219 1 [F 1 3


    ...-. - .            .- ..          .- - - - .=.~                     -.~. . . - ~ . - -                     -              - . ~.       -. - - - .-.                        ..    - - . - - . -              .-              -
.- - - -.=.~
O v                                                                                           J                                                                                              s
-.~... - ~. - -
<                                                                                                                                                                                                                                          i NOTD THIS IS A SIMPLIFIED                                                                                     ,L C,         p.
-. ~.
DIAGRAM USED TO DEPICT                                                                                      r,                                                                                                            _
O J
A TEST CIRCUIT. REFER                                                                                     (006)
v s
TO THE P&ID FDR DETAILS.                                                                                                                                                   HV                                                     I 9003 OMCB                                                                         QMCB                                                               b 9001 HV                  TI    PI M 1094 r'
i NOTD THIS IS A SIMPLIFIED
,L C, p.
A TEST CIRCUIT. REFER (006)
DIAGRAM USED TO DEPICT r,
TO THE P&ID FDR DETAILS.
HV I
9003 OMCB QMCB b
9001 M
FROM CONTAINMENT i
FROM CONTAINMENT i
9001A                 0938 0974                                                           PI                   12"                         EMERGENCY SUMP                 FI     __
HV TI PI 1094 r'
TO                 M                                                                                         0972                                                                               929        .
9001A 0938 0974 PI 12" EMERGENCY SUMP FI 929 TO M
                                                                                                  =
0972
i CONTAINMENT = ,' ,                                                               '
=
SPRAY                           8, l
i CONTAINMENT =,',
                                                                                                    } 12*                                    i n         r 1-1206-P6-001                                           n o
} 12*
8 CONTAINMENT SPRAY PUMP g                                                  %'C3 S                                                                       '
i SPRAY 8,
CONTAINMEN SPRAY EDUCTOR e
l r
8 SPRAY ADDITIVE TA W                                                           M    9017A 1-1206-J6-001       2 3'           HV           3'       HV                                       90   A.                                 -
n 1-1206-P6-001
S                        994                    994 REFUELING VATER                 c 3                                         CB                         MCB STORAGE TANK gh           3'] g 94        )   M         994           2'           098             1-1204-T4-001 e                 l                                                                     =
%'C3 n
CONTAINMENT SPRAY EDUCTOR h
o CONTAINMENT SPRAY 8
o M
g PUMP S
r HV
3 CONTAINMEN SPRAY ADDITIVE e
* 10     9017B 1-1206-J6-002                                                             (13_'2) 1                                                 MCB 9001B                                           '
SPRAY EDUCTOR 8
HV                                                         MCB                                                          M r                                                                                                       9017 9001B g} Cs                          1094             pg                                               y 0973                                               3              HV TD                   m            8'                                     i                                                                                     9003                                                         i' CONTAINMENT SPRAY r'
M 9017A TA W 1-1206-J6-001 2
::    2" 1-1206-P6-002 h                                                                ,
S 994 994 f
PI                                                                                      l                  -              FROM CONTAINMENT CONTAINMENT SP' RAY                                     12'       r' 0975                                                                                                                          EMERGENCY SUMP I I PUMP 1
3' HV 3'
                                                                                                                ,L C,         p.
HV 90 A.
  =v-     ==     =     ===                             === mum                           .=,
REFUELING VATER c
dich
3 CB MCB STORAGE TANK gh 3'] g
                                                                                -2                 .-.      .      .      .
)
e       e-em   :n     vi       maan run m                                     -i                                                                                       .
M 994 2'
i        **    ==    cvs      wts = u.amm av e                               _c e        *-sw   ees m
098 1-1204-T4-001 94 e
vs       u ems = ts.amm av w oss amm. . -
l
                                                                                -I ie-e-w oc                                       Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT                     asino n                       mm. sec UNIT 1                           '""                        c"*     vs                       ;
=
                                                                                                                                                                              ~
CONTAINMENT h
PUMP INSERVICE TESTING LOOP FOR CONTAINMENT SPRAY PUMP
M HV i
                                                                                                                                                                                      ~
SPRAY EDUCTOR o
ua         UEn 1-1206-P6-002                           N/A       N/A         ISI-D- 220         1 (F 1 3
10 9017B (13_'2) r 1-1206-J6-002 1
MCB 9001B MCB HV M
9017 r
9001B g} s 1094 y
pg C
0973 TD 8'
3 HV i
9003 m
i h
2" CONTAINMENT r'
SPRAY 1-1206-P6-002 l
FROM CONTAINMENT PI CONTAINMENT SP' RAY 12' r'
EMERGENCY SUMP 0975 PUMP I I
,L C, p.
1 dich
=v-
 
==
=
 
===
=== mum
-2
.=,
e e-em
:n vi maan run m
-i r
e
*-sw ees vs u ems = ts.amm av w
> _c i
 
==
cvs wts = u.amm av e
-I ie-e-w m
oss amm.. -
oc Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT asino n mm.
sec UNIT 1 c"*
vs
~
PUMP INSERVICE TESTING LOOP
~
ua UEn i
FOR CONTAINMENT SPRAY PUMP 1-1206-P6-002 N/A N/A ISI-D-220 1 (F 1 3
J


CVCS Pumps CENTRIFUGAL CHARGING PUMPS l
CVCS Pumps CENTRIFUGAL CHARGING PUMPS l
  ,,                                          (1-1208-P6-002, & 003) k-       System Function                 ~
(1-1208-P6-002, & 003) k-System Function The primary functions of the CVCS are to:
The primary functions of the CVCS are to:
~
l Regulate reactor coolant chemistry for reactivity and         ,
l Regulate reactor coolant chemistry for reactivity and corrosion control l
corrosion control                                               l Maintains the water level in the pressurizer of the RCS       j Maintains seal-water injection flow to the reactor             I coolant pump
Maintains the water level in the pressurizer of the RCS j
                                                                                                                      )
Maintains seal-water injection flow to the reactor I
Provide a means offilling, draining and pressure testing the RCS Provide injection flow to the RCS following actuation ofSIS Quantity                               2 l
e coolant pump
!        Type Horizontal, centrifugal,11 itaIg                                   i i
)
          . Manufacturer /Model                   Pacific, U 2-1/2 in., RL l         Capacity                               150 gpm Total Dynamic Head                     5800 ft.
Provide a means offilling, draining and pressure testing the RCS Provide injection flow to the RCS following actuation ofSIS Quantity 2
Driver                                                                                                     1 Type                             Westinghouse electric motor
l Type Horizontal, centrifugal,11 itaIg i
              ~ Horsepower                     600 Speed                             1800 rpm Power Supply                     4160V,60 Hz,3 phase Code Class                             2 Project Class                           212                                                                 {
i
Outline Drawing                         IX6AH02-101 i
. Manufacturer /Model Pacific, U 2-1/2 in., RL l
Instruction Book                       IX6AH02-85 Physical Location Aux Bldg, Level C, Rooms R-Cl15 & R-C118 P&ID                                   IX4DB116-2 Surveillance Procedure                 1480~8-1 1
Capacity 150 gpm Total Dynamic Head 5800 ft.
Pump Test Loop Diagrams               ISI-D-221& ISI-D-222                                                 i l       Test Parameter Sheets                 Page 10-2 & 10-3 10-1                                                   Rev.0
Driver 1
Type Westinghouse electric motor
~ Horsepower 600 Speed 1800 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2
Project Class 212
{
i Outline Drawing IX6AH02-101 Instruction Book IX6AH02-85 Physical Location Aux Bldg, Level C, Rooms R-Cl15 & R-C118 P&ID IX4DB116-2 Surveillance Procedure 1480~8-1 1
Pump Test Loop Diagrams ISI-D-221& ISI-D-222 i
l Test Parameter Sheets Page 10-2 & 10-3 10-1 Rev.0


f~                                                                                                                                                            3
3
                - (%))                                                                                                                                                 (                                                                                                                                                 (d                     ,
- (%))
Test Parameter Table - Pump 1-1208-P6-0<)2 (Figure ISI-D-221)
f~(
* Instrumentation Utilized                                                         Ref.     Acceptsble       Alert                                                           Action                                                                                 ,
(d Test Parameter Table - Pump 1-1208-P6-0<)2 (Figure ISI-D-221)
Paramtitt         Test Freq.                             I.D. NoJ3 n                             Range                         Ecsl. Acc.                 Yalue     Bange             Range                                                           Range                           Comments -
Instrumentation Utilized Ref.
Speed (N)                 NA                                   NA                                     NA                             NA                         NA       NA               NA                                                               NA                             Constant speed driver inlet PI-8891                               0-100                           12%                         NA       NA               NA                                                               NA                             NA                                                     i Pressure          Qtr (Pi)                                                                                           psig                                                                                                                                                                                                                                           l Outlet                                                                                                                                                                                                                                                                                                                                         .
Acceptsble Alert Action Paramtitt Test Freq.
Pressure           Qtr                                   PI-8472                               0-4000                         12%                         NA       NA               NA                                                             NA                               NA                             i                       I (Po)                                                                                           psig Differ.
I.D. NoJ3 n Range Ecsl. Acc.
Pressure           Qtr                                   NA(1)                                 NA                             12%                         APr       .90 - 1.10APr     NA                                                             <.90 er >l.10APr NA (AP)
Yalue Bange Range Range Comments -
Flowrate           Qtr                                   F1-10120                             0-80                             12%                         Qr       NA               NA             ,                                              NA                               Flowrate is set at reference value (Q)                                                                                           gpm i
F Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-8891 0-100 12%
NA NA NA NA NA i
(Pi) psig l
Outlet Pressure Qtr PI-8472 0-4000 12%
NA NA NA NA NA I
i (Po) psig
[
Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er >l.10APr NA (AP)
Flowrate Qtr F1-10120 0-80 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm i
Vib.
Vib.
Amp.               Qtr                                   (2)                                   NA                               i5%                         Vr       s 2.5Vr           > 2.5Vr - 6Vr                                                 >6Vr or                           NA (V)(4)                                                                                                                                                                                 or >.325 in/s                                                 >.70 in/s i
Amp.
N:t:s:                                                                                                                                                                                                                                                                                                                                         ;
Qtr (2)
: 1. Differential pressure is calculated as, AP = Po - Pi                                                                                                                                                                                                                                                                                         f
NA i5%
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                                                 l
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s i
N:t:s:
: 1. Differential pressure is calculated as, AP = Po - Pi f
: 2. Portable vibration instruments are utilized.
l
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.                                                                                                                                                                                                                                                                                         ,
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
i 10 -2                                                                                                                       Rev.0
i 10 -2 Rev.0


(
(
(                                                                           V Test Parameter Table - Pump 1-1208-P6-003 (Figure ISI-D-222)
(
Instrumentation Utilized           Ref.         Acceptable     Alert             Action Test Freo.       I.D. No.(3)   Range         Req. Arc, Yalut           Range           Range             Range               Comments Parameter Speed NA               NA             NA           NA         NA           NA             NA               NA                 Constant speed driver (N) inlet Pressure                             PI-8892       0-100         12%         NA           NA             NA               NA                 NA Qtr (Pi)                                               psig Outlet PI-8473       0-4000       12%         NA           NA             NA               NA                 NA Pressure            Qtr (Po)                                               psig Differ.
V Test Parameter Table - Pump 1-1208-P6-003 (Figure ISI-D-222)
Pressure           Qtr             NA(1)         NA           12%         APr           .90 - 1.10APr   NA               <.90 or >l .10APr NA (AP)
Instrumentation Utilized Ref.
FI-10121       0-80         12%         Qr           NA             NA               NA                 Flowrate is set at reference value Flowrate            Qtr (Q)                                                 gpm Vib.
Acceptable Alert Action Parameter Test Freo.
Amp.                                 (2)           NA           i5%         Vr           s 2.5Vr         > 2.5Vr - 6Vr     >6Vr or             NA Qtr or >.325 in/s     >.70 in/s (V)(4)
I.D. No.(3)
Range Req. Arc, Yalut Range Range Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-8892 0-100 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8473 0-4000 12%
NA NA NA NA NA (Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr FI-10121 0-80 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA or >.325 in/s
>.70 in/s (V)(4)
Notes:
Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
Line 1,458: Line 2,938:
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
10 -3                                                             Rev.0
10 -3 Rev.0


_        ~_                   _    ._.          ..
~_
O                                                                               (
O
                                                                                                    %)
(
(
(
O 3'               SEAL VATER                                                                                     $                    3' i l@       1             -120 -      -
%)
U i
O 3'
3' P MP                                                                                   RVST SEALS                         3'                   @                  l     8110
SEAL VATER i
                                                                                                          '"                                                                      VOLUME O g_gTgK     _
3' l@
RHT                     rt                                                                 3*                                                                           L j g CVCS                                                                                                                                                                                             N REGENERATIVE HEAT N
1
Fv Da0 G3D W
-120 -
6 8111A H
U 3'
1-1208-P6-001 POSITIVE DISPLACEMENT 3'       4           g3g ll2B
i P MP RVST SEALS 3'
_          CHARGING PUMP                                                             MCB 121 EXCHANGER                           IN         FT 21 QMC HS                   FI                                         MCB                                     -
l 8110 VOLUME O g_gTgK RHT rt 3*
112C QMCB                                                 '                          8 2         273 485               g                                             p3 12C y                                                      018 7 8891                 @4. LD CVCS
j g L
                                                    $3                   D           i    'M                         l                                       , 6'     O                           13 REACTOR                                                                          '
CVCS 1-1208-P6-001 3'
G        ggg 4,
4 N
1-1208-P6-002 COOLANT PUMP                                                           RHT                                                                                               H SEALS                                             MCB                       1   g                                     F               CENTRIFUGAL 10118         CHARGING PUMP                   471 J LRHT                                                                                                     'V F1                                 QMCB                         HST NOTE: THIS IS A SIMPLIFIED DIAGRAM HS 485           3'       IUI I PI       &                              47I              8 USED TO DEPICT A TEST                                             HV                                     q             8473       274                     PI             MCB PI CIRCUIT. REFER TO THE                                             485                                                                           8892     0188 P&I.D. FOR DETAILS.                                                                             j
N g3g REGENERATIVE Da0 W
* 8' M 4                    n ll;           1
H POSITIVE DISPLACEMENT ll2B HEAT Fv G3D 6 8111A CHARGING PUMP 121 MCB EXCHANGER IN FT QMC 21 HS FI MCB 112C QMCB 8 2 273 485 g
                                                                                                                                        )                           6'                     GH9)
p3
O                                         1-1208-P6-003 RHT                                                                   CENTRIFUGAL                     H             LV 012                                                   4 71           112E CHARGING PUMP HV                     HV                                                                                                       HS 803                     803                         1 G               508                                                   4 71                         FROM SIS BORON                                     J LRHT                                                                           MCB
@4. LD 12C 018 7 y
                                                                                                        ,                                                                                    REFUELING INJECTION TANK                                             r,                     RVST                                                                VA TER 1-1204-V6-001                                                                                                                             STORAGE TANK
8891 CVCS
-v-   .m     a                             ==-1=                   -u     -.,  .-2     m. m.   -
$3 D
9     FM     Elt   WS ISSLES FtR Pf7                               fI a     7-e*-w ==     cvs urnmn in in4 sam-e arv w                     JJC a E "o_2 [             ,,                      h                                 Southern Company Services. Inc.FOR Southern Nuclear Operofing Company E             ~n 7rnY w~n U n m N .".n                                         V0GTLE ELECTRIC GENERATING PLANT "                 " * * * "               8       "c s     re+=   m     ox5 wn w s. . cama                                                                                         UNIT 1                   " ,"'                    g"a" ym, PUMP INSERVICE TESTING LOOP                                 -on.               -.          ar .
'M l
FOR CENTRIFUGAL CHARGING PUMP 1-1208-P6-002                   N/A         N/A     ISI-D- 221       1 IT I 5
, 6' O
i 13 G
4, REACTOR ggg 1-1208-P6-002 COOLANT PUMP RHT SEALS MCB 1 g F
CENTRIFUGAL H
10118 CHARGING PUMP 471 J LRHT F1 QMCB HST
'V NOTE: THIS IS A HS IUI I 47I 8
SIMPLIFIED DIAGRAM 485 3'
PI USED TO DEPICT A TEST HV q
8473 274 PI MCB PI 0188 CIRCUIT. REFER TO THE 485 8892 8' M P&I.D. FOR DETAILS.
4 j
ll;
)
6' GH9) n 1
O 1-1208-P6-003 RHT CENTRIFUGAL H
LV 012 CHARGING PUMP 4 71 112E HV HV HS 803 803 1 G 508 4 71 FROM SIS BORON J LRHT MCB REFUELING INJECTION TANK RVST r,
VA TER 1-1204-V6-001 STORAGE TANK
-v-
.m a
 
==-1=
-u
.-2 m.
m.
9 FM Elt WS ISSLES FtR Pf7 fI a
7-e*-w
 
==
cvs urnmn in in4 sam-e arv w JJC E "o_2 [
h Southern Company Services. Inc.FOR Southern Nuclear Operofing Company a
E
~ 7rnY w~n U n m N.".n V0GTLE ELECTRIC GENERATING PLANT " " * * * "
8 "c
s re+=
m ox5 wn w s.. cama UNIT 1 g"a" ym, n
PUMP INSERVICE TESTING LOOP
-on.
ar FOR CENTRIFUGAL CHARGING PUMP 1-1208-P6-002 N/A N/A ISI-D-221 1 IT I 5


I
I
                                                                                                                                                                                    ~
~
                    '% I                                                                         's )                                                                           w 3'             SEAL VATER                                                                                 LC i l         1           -120 - -
I
3' 3*
's )
MP                                                                             RVST 3,                                                                   ,'
w 3'
SEALS                 g                                                 8110                                                                                     VOLUME            i
SEAL VATER LC 3'
                      =    O                                                                                                                                        OggigK                   hg C                                     1LT E RHT                   rr                                                             3' h                                                                                        '
i l 1
CVCS                                                                                                           1-1208-P6-001                         3'         4                     112B REGENERATIVE               )                 ll               DE}
-120 - -
H                     POSITIVE DISPLACEMENT HS HEAT                   @                        Fv       G3D       G23) BillA                   _._      CHARGING PUMP ll2B EXCHANGER                         g$       FT    121                                                                                                                                   MCB QMC HS                                                         MCB 0121                                      FI                                                                          -
3*
112C QMCB                                       "
MP RVST VOLUME i
3485             g                 8 72       273         pg y                                              018 7     4. LO                 12C 8891             --{$RJ
3, SEALS g
                                                                        ?                                                   '                                O CVCS                                      hg                                  Vi                       b               ;)                 , 6'                                 013 REACTOR                                                                         G       g 4,
8110 O
1-1208-P6-002 CDDLANT PUMP                                                       RHT 1 G                                   FD             CENTRIFUGAL               H SEALS                                          MCB                          .                                                                          471 J LRHT                               10118        CHARGING PUMP FI                             QMCB                     HS                           V NOTE: THIS IS A                                                       HS                     10121                                                                                 112D SIMPLIFIED DIAGRAM                                                 485           3, PI         g3                       4 71                 8-USED TO DEPICT A TEST                                         HV                                   q           8473     274         pl      PI           MCB CIRCUIT. REFER TO THE                                         485   g                                                                       0188 P&I.D. FOR DETAILS.
OggigK hg C
q I
1LT E
ili 8892                                M-af "
=
O I
RHT rr h
                                                                                                                                  )                     6'                     GH9)
3' CVCS 1-1208-P6-001 3'
                                                                                                                                                                                          ~
4 112B REGENERATIVE
1-1208-P6-003 RHT 1012                CENTRIFUGAL                   H               LV CHARGING PUMP                 4 71             112E HV                   HV                                             gy                                             HS 803                   803B-2 LRHT      p    508                                             4 71                             FROM SIS BORON                                  J MCB               REFUELING INJECTION TANK                                           r,                 RVST VATER 1-1204-V6-001                                                                                                                     STORAGE TANK uv.   ==     e,     o.,                   ww -                         -m     -m   m.   -s
)
                                                                    -.2                              ====s
ll DE}
  .    --              .,      ,. m                               er
H POSITIVE DISPLACEMENT ll2B HS HEAT Fv G3D G23) BillA CHARGING PUMP EXCHANGER g$
  ,    --    -        m  _ , . . . .                            aac 7.
121 MCB FT QMC 0121 HS FI MCB 112C QMCB 3485 g
[
8 72 273 pg 018 7
                            .",",'Z.",,,,,
: 4. LO 12C y
                                                                            "E Southern Company Services. Inc.rOR Southern Nuclear Operating Company Z Z", 7,,7.".n".,,,*,",,, C"n                                           VDGTLE ELECTRIC GENERATING PLANT           ==8     "                  **    ""C s     se+* ==       zwJ .s. s =4en                                                                                 UNIT 1 m _                             , , , ,
8891
PUMP INSERVICE TESTING LOOP                         ===         - - - -            iar   av.
--{$RJ hg
FOR CENTRIFUGAL CHARGING PUMP 1-1208-P6-003               N/A         N/A     ISI-D- 222         1 IF 1 5
?
Vi b
;)
CVCS O
, 6' 013 REACTOR G
4, g
1-1208-P6-002 CDDLANT PUMP RHT SEALS MCB 1 G FD CENTRIFUGAL H
10118 CHARGING PUMP 471 J LRHT FI QMCB V
HS NOTE: THIS IS A HS 10121 SIMPLIFIED DIAGRAM 485 3,
PI g3 4 71 8-112D USED TO DEPICT A TEST HV q
8473 274 PI MCB pl CIRCUIT. REFER TO THE 485 0188 M-g I
8892 P&I.D. FOR DETAILS.
q af "
ili I
)
6' GH9)
O
~
1-1208-P6-003 RHT CENTRIFUGAL H
LV 1012 CHARGING PUMP 4 71 112E HV HV HS gy 803 803B-508 4 71 FROM 2
J LRHT p
MCB REFUELING SIS BORON INJECTION TANK RVST r,
VATER 1-1204-V6-001 STORAGE TANK uv.
 
==
e, o.,
ww -
-.2
-m
-m m.
-s
 
====s
,. m er m
aac
: 7. [
.",",'Z.",,,,,
Southern Company Services. Inc.rOR Southern Nuclear Operating Company "E
Z Z", 7,,7.".n".,,,*,",,, C"n VDGTLE ELECTRIC GENERATING PLANT==8
""C s
se+*
 
==
zwJ
.s.
s =4en UNIT 1 m _
PUMP INSERVICE TESTING LOOP
 
===
iar av.
FOR CENTRIFUGAL CHARGING PUMP 1-1208-P6-003 N/A N/A ISI-D-222 1 IF 1 5


l BORIC ACID TRANSFER PUMPS l
l BORIC ACID TRANSFER PUMPS l
Line 1,518: Line 3,084:
)
)
borated water. The boric acid transfer system also provides boric acid for emergency boration of the RCS.
borated water. The boric acid transfer system also provides boric acid for emergency boration of the RCS.
Quantity                                     2 Type                                         Canned motor Manufacturer /Model                         Chempump Model GVH-1K Design Flowrate                             75 gpm l           Design Head                                   235 ft.
Quantity 2
l           Driver
Type Canned motor Manufacturer /Model Chempump Model GVH-1K Design Flowrate 75 gpm l
;                  Type                                   Electric motor kW                                     15.5 i                 Speed                                 3450 rpm
Design Head 235 ft.
)                 Power Supply                         4160V,60 Hz,3 phase Code Class                                   3
l Driver Type Electric motor kW 15.5 i
'O
Speed 3450 rpm
!          Project Class                               313 Outline Drawing                               IX6AH02-45 j           Instruction Book                             2X6AA07-10 Physical Location                           Aux Bldg, Level D P&ID                                         1X4DB118 Surveillance Procedure                       14811-1 Pump Test Loop Diagrams                     ISI-D-228& ISI-D-229 Test Parameter Sheets                       Page 11-2 & 11-3 O
)
11 - 1                               Rev.0 4
Power Supply 4160V,60 Hz,3 phase Code Class 3
'O Project Class 313 Outline Drawing IX6AH02-45 j
Instruction Book 2X6AA07-10 Physical Location Aux Bldg, Level D P&ID 1X4DB118 Surveillance Procedure 14811-1 Pump Test Loop Diagrams ISI-D-228& ISI-D-229 Test Parameter Sheets Page 11-2 & 11-3 O
11 - 1 Rev.0 4


Test Parameter Table - Pump 1-1208-P6-006 (Figure ISI-D-228)
Test Parameter Table - Pump 1-1208-P6-006 (Figure ISI-D-228)
Instrumentation Utilized           Ref.       Acceptable     Alert                                   Action                                                                                                           j Parameter                   Test Freq.             I.D. NoJ3)   Range         Req. Acc. Value       Range           Range                                   Range                 Commenh Speed (N)                         NA                     NA           NA             NA           NA       NA               NA                                       NA                   Constant speed driver Inlet Pressure                   Qtr                   PI-10115     -15 to +15       2%         NA       NA               NA                                       NA                     Relief Request RR-P-1 (Pi)                                                             psig Outlet Pressure                   Qtr                   Pl-Oll3       0-160         12%         NA       NA               NA                                       NA                     NA                                                         i (Po)                                                             psig DilTer.
Instrumentation Utilized Ref.
Pressure                   Qtr                   NA(1)         NA             12%         APr       .90 - 1.10APr   NA                                       <.90 er >l.10APr NA (AP)
Acceptable Alert Action j
Flowrate                   Qtr                   FI-40001     0-100           t2%         Qr       NA               NA                                       NA                     Flowrate is set at reference value (Q)                                                             gpm Vib.
Parameter Test Freq.
Amp.                       Qtr                   (2)           NA             15%         Vr       s 2.5Vr         > 2.5Vr - 6Vr                           >6Vr or               NA (V)(4)                                                                                                                   or >.325 in/s                           >.70 in/s Nstes:
I.D. NoJ3)
Range Req. Acc.
Value Range Range Range Commenh Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-10115
-15 to +15 2%
NA NA NA NA Relief Request RR-P-1 (Pi) psig Outlet Pressure Qtr Pl-Oll3 0-160 12%
NA NA NA NA NA i
(Po) psig DilTer.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er >l.10APr NA (AP)
Flowrate Qtr FI-40001 0-100 t2%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA 15%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Nstes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Portable vibration instruments are utilized.
: 1. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing ho'ising and in the axial direction on each accessible thnist bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing ho'ising and in the axial direction on each accessible thnist bearing housing.
11 - 2                                                                                                                               Rev.0
11 - 2 Rev.0


                                                                      '\                                                                                                                                             f')                                                                                                                               p
'\\
                                                            ~                                                                                                                                                        %./                                                                                                                               Q Test Parameter Table - Pump 1-1208-P6-007 (Figure ISI-D-229)
f')
Instrumentation Utilized                                     Ref.     Acceptable               Alert             Action Parameter                                           Test Freq.                                     I.D. NoJ3)                                   Range           Req. Acc.         Value     Range                   Range             Range                                                           Comments Speed (N)                                                 NA                                             NA                                           NA             NA                   NA       NA                       NA               NA                                                               Constant speed driver Inlet Pressure                                             Qtr                                             PI-10l l6                                   -15 to +15   12%                   NA       NA                       NA               NA                                                               Relief Request RR-P-1 (Pi)                                                                                                                                             psig Outlet Pressure                                             Qtr                                             PI-0114                                     0-160         i2%                   NA       NA                       NA               NA                                                               NA                 i (Po)                                                                                                                                             psig Differ.
p
Pressure                                             Qtr                                           NA(1)                                         NA           12%                   APr       .90 - 1.10aPr             NA               <.90 or >l.10APr NA (AP)
%./
Flowrate                                             Qtr                                           F1-40001                                     0-100       12%                     Qr       NA                       NA               NA                                                               Flowrate is set at reference value (Q)                                                                                                                                               gpm Vib.
Q
Amp.                                                 Qtr                                           (2)                                           NA         i5%                     Vr       s 2.5Vr                   > 2.5Vr - 6Vr     >6Vr or                                                         NA (V)(4)                                                                                                                                                                                                                   or >.325 in/s     >.70 in/s Notes:
~
Test Parameter Table - Pump 1-1208-P6-007 (Figure ISI-D-229)
Instrumentation Utilized Ref.
Acceptable Alert Action Parameter Test Freq.
I.D. NoJ3)
Range Req. Acc.
Value Range Range Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-10l l6
-15 to +15 12%
NA NA NA NA Relief Request RR-P-1 (Pi) psig Outlet Pressure Qtr PI-0114 0-160 i2%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10aPr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr F1-40001 0-100 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration inst uments are utilized.
: 2. Portable vibration inst uments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shcft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                                                                                                                                       s direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shcft in two orthogonal directions on each accessible pump-bearing housing and in the axial s
11 - 3                                                                                                                 Rev.0
direction on each accessible thrust bearing housing.
11 - 3 Rev.0
 
f D
V}
(V V
NOTE THIS IS A V
SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TD 3 7 PLI.D. IX4DB118 FOR (x-Ann) jg DETAILS.
FROM BRS RECYCLE LD LD TO BDRIC EVAPORATOR g
ACID 2'
X X
e
@ FILTER 011 eZ ll!
ir m
(1 (1
i D
U 1h*2 = ;;;
2'
=
1 e
am e
i BORIC ACID 000 TRANSFER PUMP LC i
BORIC ACID l-1208-P6-007 2'
a BORIC ACID FILTER BYPASS 2*
STORAGE TANK SEE ISI-D-229 TD BORIC ACID BLENDER 7'
1-1208-T4-003 O
3' FU,TURE DMCB NE'U 6
J L I
3' PP 113 011 LO
', C N
Z LO La
= 2 > (0 1, 3 X
=
e e
Mc, e
3 m
e S{ [
t 3][G l-1 8-P6g06 SAMPLE B
Y ACID TRANSFER PUMPS TO UNIT 2 BORIC TRANSFER PUMP
+
7 U-
.c" c5i) J7c
"~
~
~
~
~
vs unasrm m i av
,- -es ces vs asers ri===
WLV MB Z
2, E h".".",".".,
Southern Company Services. inc. FOR Southern Nuclear Operating Company VDGTLE ELECTR ENERATING PLANT "_5 = =
=
""' =


f                                                                          D V}                                                                      (V                                                                                V NOTE THIS IS A SIMPLIFIED DIAGRAM                                                                                                                                V USED TO DEPICT A TEST CIRCUIT. REFER TD                                                                                                                                3 7 PLI.D. IX4DB118 FOR                                                                                                                    (x- Ann) jg DETAILS.
==z com m e eimari PUMP INSERVICE TESTING LOOP FOR r=ana seaws.i -
FROM BRS RECYCLE                                                                                      LD                    LD    TO BDRIC EVAPORATOR                                                g                                                                    ACID      2' X                    X
ours arv.
* 011 e                      @ FILTER e
BORIC ACID TRANSFER PUMP 1-1208-P6-005 N/A N/A ISI-D-228 1 IF 1 3
Z'"          ll!                                    ir m                                  (1                                    (1 i
U                                                                                D                                                      #
1h*2 = ;;;                                                              -                                2'
                                                                                                                                        =
1                                e          am                              e i          BORIC ACID 000      TRANSFER PUMP                                                                                                                          i LC BORIC ACID                                        l-1208-P6-007                                                                2'      a          BORIC ACID FILTER BYPASS 2*
STORAGE TANK                                      SEE ISI-D-229                                                                          7' TD BORIC ACID BLENDER 1-1208-T4-003                                                                                                                            O 3' FU,TURE                                          DMCB
                                            @            NE'U                                      6 J L 3'
I  PP                                  113 011
                                                                                                                                    ,    LO LO            La                                    ', C          N              Z 1, 3 =                          X                        ,
                                                                                      = 2 > (0 Mc,            e          3  m e              e                                                  .
e                      S{ [
t SAMPLE            3] [G                                    l-1 B    8-P6g06                                                                                    !
TO UNIT 2 BORIC                  TRANSFER PUMP                                                                                      +
                    "'                          "~
Y ACID TRANSFER PUMPS 7 U-        .c"    vs    unasrm m i av                          c5i) J7c
                                                                              ~    ~  ~      ~
,    ,- -es  ces    vs      asers ri ===                          WLV MB
,    Z      2,  E        h".".",".".,                          $                            Southern Company Services. inc. FOR Southern Nuclear Operating Company VDGTLE ELECTR        ENERATING PLANT                    =          ""' =
                                                                                                                                                "_5 = =
                                                                                                                                                ==z               com m e eimari PUMP INSERVICE TESTING LOOP FOR                           r=ana   seaws.i -     ours arv.
BORIC ACID TRANSFER PUMP 1-1208-P6-005                           N/A       N/A   ISI-D- 228     1 IF 1 3   ,


O                                                                                   O                                                                                                                                                                                                             O NOTE THIS IS A                                                                                                                                                                                                                                                                                     v SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TD                                                                                                                                                                                                                                                                             F PLI.D. IX4DBil8 FOR                                                                                                                                                                                                                                                         (X- 800) Jk DETAILS.
O O
FROM BRS RECYCLE                                                                                                                                                                                                                           LO                         LO       10 BORIC EVAPORATOR                                                                           b,                                                                                                                                               X                           X       F     ER GL"D                       GB7)
O NOTE THIS IS A v
                                                                                                                                                                '011 2   1 X                                           lll y
SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TD F
U
PLI.D. IX4DBil8 FOR (X-800) Jk DETAILS.
                                                                                                                            'o m
FROM BRS RECYCLE LO LO 10 BORIC EVAPORATOR b,
                                                                                                                                                                                                                                                                          ;[-                                       '
X X
(1                                                                                                                                     L1                             i P                                                                                         LO                                                                                                                               LO 14H: p. :         lil                                                                             M                   Dec 2'
F ER GL"D GB7)
                                                                                                                                                                                                                                                                              =X 1                                               e                 am                                                                                                                                       m I               BORIC ACID 000             TRANSFER PUMP                                                                                                                                                                                                           LC BORIC ACID                                           l-1208-P6-006                                                                                                                                                                                                 2*     n           BORIC ACID FILTER BYPASS _
'011 2 1 X
STORAGE TANK                                         SEE ISI-D-228                                                                                                                                                                                                         7' TO BORIC ACID BLENDER 1-1208-T4-003                                                                                                                                                                                                                                                               O 3' FUTURE                                                         OMC y
lll U
Jk eM'o                 I 3'                     PP                                                                                                       11 4 on                                                                                                                                                                                       . to 1i. 3'=                              X
y
                                                            'O              '
;[-
i                                    :                .C                                                                             N                                       X                                                       l
'o m
                                                                                              .    = 3.>. (O           ..
(1 L1 i
e                                               e m
P LO 2'
LO 14H: p.: lil M
Dec
=X 1
e am m
I BORIC ACID 000 TRANSFER PUMP LC BORIC ACID FILTER BYPASS _
BORIC ACID l-1208-P6-006 2*
n STORAGE TANK SEE ISI-D-228 7'
TO BORIC ACID BLENDER 1-1208-T4-003 O
3' FUTURE OMC eM'o y
J k I
11 4 3'
PP on to
.C N
X l
'O
= 3.>. (O 1i 3'=
X i
e e
60~
60~
GTA 3'
m 3'
S$ [ 5 G8a SAMPLE              3]   [G               2:!
G8a GTA S$[ 5 3][G 2:!
l-th8-P6-007 B             C TO UNIT 2 BORIC                           TRANSFER PUMP uv. se Y ACID TRANSFER PUMPS av oari                         mwanem                   mu     ===   mu         me   mas               ames a     w-en* nac   vs   naza nst est i ist                           CVD _lJC i     =-*-se ese   we   aesce rr esem                               VLV MB Se     N3             mE                                     3                                            Southern Company Services, Inc.FOR Southern Nuclear Operating Company VOGTLE ELECTRIC GENERATING PLANT =*** *                                                                                                                                                 **=       e UNIT 1                                                                                                             '"'                      ' " " ' " v5 EA1   am               CENTDEAe De Isti PUMP INSERVICE TESTING LOOP FOR                                                                                                                                         emana         en.w     =m       meu =v.
l-th8-P6-007 SAMPLE B
BORIC ACID TRANSFER PUMP 1-1208-P6-007                                                                                                                                     N/A       N/A       ISI-D- 229         1 IF 1 3
C Y ACID TRANSFER PUMPS TO UNIT 2 BORIC TRANSFER PUMP uv.
se av oari mwanem mu
 
===
mu me mas ames a
w-en*
nac vs naza nst est i ist CVD _lJC i
=-*-se ese we aesce rr esem VLV MB Se N3 mE Southern Company Services, Inc.FOR Southern Nuclear Operating Company 3
VOGTLE ELECTRIC GENERATING PLANT =*** *
**=
e UNIT 1
' " " ' " v5 EA1 am CENTDEAe De Isti PUMP INSERVICE TESTING LOOP FOR emana en.w
=m meu
=v.
BORIC ACID TRANSFER PUMP 1-1208-P6-007 N/A N/A ISI-D-229 1 IF 1 3


I i
I i
AFW Pumps (1-1302-P4-001,002 & 003)
AFW Pumps (1-1302-P4-001,002 & 003)
System Functior v                                      '
System Functior Supply water to the steam generators whenever the reactor v
Supply water to the steam generators whenever the reactor coolant temperature is above 350'F and the main feedwater system is not in operation, i.e., during startup, cooldown, or             '
coolant temperature is above 350'F and the main feedwater system is not in operation, i.e., during startup, cooldown, or emergency conditions resulting in a loss of main feedwater.
emergency conditions resulting in a loss of main feedwater.
Automatically provides feedwater for the removal of reactor core decay heat following a loss of main feedwater.
Automatically provides feedwater for the removal of reactor core decay heat following a loss of main feedwater.
This prevents damage to the reactor core until the reactor coolant temperature is brought from a hot standby condition to the point at which RHR may be placed into i
This prevents damage to the reactor core until the reactor coolant temperature is brought from a hot standby condition to the point at which RHR may be placed into operation.
operation.
i AFW mpplies feedwater to the steam generators at a flowrate sufficient to support normal low-power transients such as startup, cooldown, and hot standby.
AFW mpplies feedwater to the steam generators at a flowrate sufficient to support normal low-power transients l
l Turbine Driven AFW Pumo (1-1302-P4-001) l Quantity
such as startup, cooldown, and hot standby.
}
Turbine Driven AFW Pumo (1-1302-P4-001) l           Quantity                             }
Type Horizontal, centrifugal,5 stage, split-case Manufacturer /Model Ingersoll-Rand, Model 6HMTA Capacity 1175 gpm Total Dynamic Head 3500 ft.
Type Horizontal, centrifugal,5 stage, split-case
Driver Type Terry Turbine, Model GS-2N, non-condensing, single-stage, mechanical drive Horsepower 1603 Speed 4250 rpm Power Supply Steam Code Class 3
:          Manufacturer /Model                 Ingersoll-Rand, Model 6HMTA Capacity                             1175 gpm Total Dynamic Head                   3500 ft.
Project Class 313 Outline Drawing IX4AF03-83 Instruction Book IX4AF03-20033 12 - 1 Rev.O
Driver Type Terry Turbine, Model GS-2N, non-condensing, single-stage, mechanical drive Horsepower                   1603 Speed                       4250 rpm Power Supply                 Steam Code Class                           3 Project Class                         313 Outline Drawing                       IX4AF03-83 Instruction Book                       IX4AF03-20033 12 - 1                                 Rev.O


Turbine Driven AFW Pumo (1-1302-P4-001)(conti Physical Location                                     AFW pump house O                         P&ID                                    ~
Turbine Driven AFW Pumo (1-1302-P4-001)(conti Physical Location AFW pump house O
IX4DB161-2 Surveillance Procedure                                 14810-1 Pump Test Loop Diagrams                               ISI-D-223 Test Parameter Sheets                                 Page 12-4 i
~
I l
IX4DB161-2 P&ID Surveillance Procedure 14810-1 Pump Test Loop Diagrams ISI-D-223 Test Parameter Sheets Page 12-4 i
l lO l
l l                                                                                                                                                    i l
l l
l l
l iO 12 - 2                   Rev.0
lO l
l l
i l
l l
l i O 12 - 2 Rev.0


      . . . - - . . _ - . _ . . .                  . . ,___.-. . . . .            . .        - -              .      . - . . ~ - -   - . . . - . . .
. -.. ~ - -
Motor-Driven AFW Pumos (1-1302-P4-002 & 003)
Motor-Driven AFW Pumos (1-1302-P4-002 & 003)
Quantity                                         2 9~
Quantity 2
Type                                       -    Horizontal, centrifugal, 6 stage, split-case i
9~
Manufacturer /Model                             Ingersoll-Rand, Model 4HMTB Design Flowrate                                 630 gpm Total Dynamic Head                               3500 ft.
Type Horizontal, centrifugal, 6 stage, split-case i
Driver Type                                     Westinghouse electric motor, LLD 5810 H l                                 Horsepower                               900 l                                 Speed                                     3600 rpm Power Supply                             4160V,60 Hz,3 phase l                           Code Class                                       3 Project Class                                   313 Outline Drawing                                 IX4AF03-81 Instruction Book                                 IX4AF03-20032 lO Physical Location                               AFW pump house P&tD                                             IX4DB161-2 Surveillane Procedure                             14807-1 1
Manufacturer /Model Ingersoll-Rand, Model 4HMTB Design Flowrate 630 gpm Total Dynamic Head 3500 ft.
l Pump Test Loop Diagrams                           ISI-D-224& ISI-D-225                                                     j 1
Driver Type Westinghouse electric motor, LLD 5810 H l
!                            Test Parameter Sheets Page 12-5 & 12-6
Horsepower 900 l
                                                                                                                                                        )
Speed 3600 rpm Power Supply 4160V,60 Hz,3 phase l
i d                                                                                                                                                       i i
Code Class 3
r I                                                                                     12 - 3                                     Rev.0 l
Project Class 313 Outline Drawing IX4AF03-81 Instruction Book IX4AF03-20032 lO Physical Location AFW pump house P&tD IX4DB161-2 Surveillane Procedure 14807-1 1
Pump Test Loop Diagrams ISI-D-224& ISI-D-225 j
l 1
Test Parameter Sheets Page 12-5 & 12-6
)
i d
i i
r I
12 - 3 Rev.0 l
i
i


o                                                                                                                                                                                                                   o                                                                                                                                             '
o o
Test Parameter Table - Pump 1-1302-P4-001 (Figure ISI-D-223)
Test Parameter Table - Pump 1-1302-P4-001 (Figure ISI-D-223)
Instrumentation Utilized                                                                                                                                 Ref.       Acceptable                                 Alert       Action Parameter         Test Freq.     I.D. NoJ3)                                                                   Range                                                                 Req.                       Arc. Yalue       Range                                       Range       Range                                                 Comments                                             '
Instrumentation Utilized Ref.
i Speed                                                                                                                                                                                                                                                                                                                                                                                                   l (N)               Qtr             SI-15109A                                                                     0-6000                                                               12%                             Nr         NA                                         NA           NA                                                   Speed is set to reference value Inlet Pressure           Qtr             PI-5110A                                                                     0-30                                                                 12%                             NA         NA                                           NA           NA                                                   NA (Pi)                                                                                                             psig t
Acceptable Alert Action Parameter Test Freq.
Outlet                                                                                                                                                                                                                                                                                                                                                                                                 .
I.D. NoJ3)
Pressure           Qtr             PI-5107A                                                                     0-2000                                                               12%                             NA         NA                                           NA           NA                                                   NA                 ,                                !
Range Req. Arc. Yalue Range Range Range Comments i
(Po)                                                                                                             psi Differ.
Speed l
1                 Pressure           Qtr             NA(I)                                                                         NA                                                                             2%                     APr       .90 - 1.10APr                               NA           <.90 or >l.10APr NA (AP)
(N)
Flowrate           Qtr             F1-15100                                                                     0-200                                                                 12%                             Qr         NA                                         NA           NA                                                   Flowrate is set at reference value                   ,
Qtr SI-15109A 0-6000 12%
(Q)                                                                                                             gpm Vib.                                                                                                                                                                                                                                                                                                                                                                                                   ;
Nr NA NA NA Speed is set to reference value Inlet Pressure Qtr PI-5110A 0-30 12%
Amp.               Qtr             (2)                                                                         NA                                                                   i5%                               Vr         5 2.5Vr -                                   > 2.5Vr - 6Vr >6Vr or                                               NA                                                   i (V)(4)                                                                                                                                                                                                                                                                         or >.325 in/s >.70in/s                                                                                                   t Notes:                                                                                                                                                                                                                                                                                                                                                                                                 !
NA NA NA NA NA
(
(Pi) psig t
Outlet Pressure Qtr PI-5107A 0-2000 12%
NA NA NA NA NA (Po) psi Differ.
1 Pressure Qtr NA(I)
NA 2%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr F1-15100 0-200 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr 5 2.5Vr -
> 2.5Vr - 6Vr
>6Vr or NA i
(V)(4) or >.325 in/s
>.70in/s t
Notes:
: 1. DifTeremial pressure is calculated as, AP = Po - Pi
: 1. DifTeremial pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
12 - 4                                                                                                                   Rev.0                                                 -
l 12 - 4 Rev.0


r                                                                                           n (s)
r n
(s)
Test Parameter Table - Pump 1-1302-P4-002 (Figure ISI-D-224)
Test Parameter Table - Pump 1-1302-P4-002 (Figure ISI-D-224)
Instrumentation Utilized                         Ref.                   Acceptable     Alert               Action                                                             l Earamcler           Test Frea.               I.D. No13)   Range                 Ben. Arc.         V_ sinc               Range         Range               Range           Comments t
Instrumentation Utilized Ref.
i Speed (N)                 NA                       NA             NA                   NA                 NA                   NA               NA                 NA               Constant speed driver i
Acceptable Alert Action l
Inlet Pressure           Qtr                     PI-5128A       0-30                 12%               NA                   NA               NA                 NA               NA (Pi)                                                       psig Outlet Pressure           Qtr                       PI-5140A       0-2000               12%               NA                   NA               NA                 NA               NA                 i (Po)                                                       psig Differ.
Earamcler Test Frea.
Pressure           Qtr                       NA(1)         NA                   i2%               APr                 .90 - 1.10APr   NA                 <.90 or >l.10APr NA (AP)                                                                                                                                                                                                                               ,
I.D. No13)
Flowrate           Qtr                       F1-15101       0-200                 12%               Qr                 NA               NA                 NA               Flowrate is set at reference value (Q)                                                         gpm Vib.
Range Ben. Arc.
Amp.               Qtr                       (2)           NA                   i5%               Vr                 s 2.5Vr           > 2.5Vr - 6Vr       >6Vr or         NA (V)(4)                                                                                                                                     or >.325 in/s       >.70 in/s                                                             !
V_ sinc Range Range Range Comments t
i Notes:
i Speed (N)
: 1. DifTerential pressure is calculated as, AP = Po - Pi                                                                                                                                                                             !
NA NA NA NA NA NA NA NA Constant speed driver i
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                     >
Inlet Pressure Qtr PI-5128A 0-30 12%
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                   !
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-5140A 0-2000 12%
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                       ;
NA NA NA NA NA i
direction on each accessible thrust bearing housing.
(Po) psig Differ.
12 - 5                                                           Rev.O f
Pressure Qtr NA(1)
NA i2%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr F1-15101 0-200 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm
(
Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s i
Notes:
: 1. DifTerential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
12 - 5 Rev.O f
t t
t t
t
t


(N._/)                                                                                       O)
( )
                                                                                                                                  %.                                                                              C)\
O)
C)\\
N._/
L.
L.
4*                                       I CONDENSATE                 CONDENSATE                         TE               15 9                 5106                                                         'I STORAGE TANK             STORAGE TANK                       5175                                                 FRON MAIN -                                           I 1-1302-V4-002             1-1302-V4-001                                           sy                             NH NU g' (Opg) 0 15133       3g         g3           QMCB                  M                            5' I HV                             5109         106A                 5107 o--
4*
J 3090       5110A
I CONDENSATE CONDENSATE TE 15 9 5106
                                                                                                                        ~'''
'I STORAGE TANK STORAGE TANK 5175 FRON MAIN -
MCB                -
I NH NU 1-1302-V4-002 1-1302-V4-001 sy g (Opg) 0 15133 QMCB M
0 GMCB LD E                                             i               6'         N       l  I      ,
3g g3 5' I HV 5109 106A 5107 o-- 3090 5110A MCB J
GIT)                     6                 ,
GMCB
HV       AUX FEEDVATER                   TURBINE DRIVEN                       i b 3[-@O I
~ ' ' '
HV 5113 dh 5093         PUM. P TURBINE 1-1302-P4-0DI-K01.
0 l
TO ATMOSPHERE 1-130g-P4-001 FEEDVATER t' UMP        FV N rd
I LD E i
[.   -
6' N
NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST I                   10'                 Y                                               MCB                     5154                                                   CIRCUIT. REFER TO THE ID M                   QMCB                             M140                                      G'         r                  P&I.D. FOR DETAILS.
3[-@O GIT) 6 HV AUX FEEDVATER TURBINE DRIVEN i b HV 5093 PUM. P TURBINE 1-130g-P4-001 N
                                                                              @                                  130A                                                   g,             AMMDMA &
rd NOTE: THIS IS A 5113 1-1302-P4-0DI-K01. TO FEEDVATER
                                                                                                                                                                                      ; HYDRAZINE HV                             ~~a       HV                           128                                 MCB                             v 5094
[.
                                                                                                                          '                ,                      @              1          6                              f 3 [_ 5098                                   8*
SIMPLIFIED DIAGRAM I
LD (U5g) i    8'                    (,                                        lr        N                        y gy                                  1-130g4-002                                                                     g 5118                                   FE g TER                                                     FV              3       ~
dh ATMOSPHERE t' UMP FV USED TO DEPICT A TEST I
2' 8                          ET)                                                                         5155             2   ,,   >
10' Y
A'                                                       QMCB                                     o   '    '
MCB 5154 CIRCUIT. REFER TO THE I M QMCB M
HV                                                                    OMC M                                                           2~
G' P&I.D. FOR DETAILS.
5092--                       HV                       OMCB 5129 131A (5141A}                                     ( lj,    I
r D
                                            -_3                                                                                                                         p HV                                     5095                                                            y II                                                                 [,        '      !        #,
130A 140 g, ; HYDRAZINE AMMDMA &
8'                                                        ltW               k" 3]_ 5099_                            HV                     LD             1-1302-P4-003 AUX GUT)                   i               LD 5119 8,                              @ (052)         8, FEEDVATER
HV
                                                                            ,                 PUMP
~~a HV 128 MCB v
            ~         -,        ,,    _                                                            ** Pea appea   m* **      **      '===
3 [_ 5098 5094 1
N PIT                                     II Q
6 f
y ee                     a uninimma-,av l
(,
1",                                                                 JJC e       =2                       ==aw m. = =3                                       DMs Southern Company Services. Inc.FOR Southern Nuclear Operating Company nea n                     sac VDGTLE ELECTRgENERATING PLANT                                        _
lr N
PUMP INSERVICE TESTING LOOP
y 8*
                                                                                                                                                                                                  ~
8' i
aa.         U     .a. e FOR AUXILLARY FEEDVATER PUMP 1-1302-P4-001                         N/A       N/A   ISI-D- 223 iTI 2
LD (U5g) 1-130g4-002 g
gy 5118 FE g TER 3
~
2' FV ET) 8 5155 2,,
A' QMCB o
OMC M 2~
HV 5092--
HV OMCB 131A (5141A}
( l I
-_3 5095 y
5129 p j, HV 3]_ 5099 II 8'
[,
ltW k
LD HV LD 1-1302-P4-003 GUT) i 5119 AUX
@ (052)
FEEDVATER 8,
8, PUMP
~
** Pea appea m*
'===
N PIT II l
y ee a uninimma-,av JJC 1", Q e
=2
 
==aw m. = =3 DMs Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRgENERATING PLANT nea n sac PUMP INSERVICE TESTING LOOP
~
aa.
U
.a.
e FOR AUXILLARY FEEDVATER PUMP 1-1302-P4-001 N/A N/A ISI-D-223 iTI 2


CT                                                                                             (
CT
U                                                                                               V                                                                             (v)
(
M                                                                                         II                           ,
U V
2.5' PV                         HV                                   NM CONDENSATE STORAGE TANK CONDENSATE STORAGE TANK TE 5175 15129                      5106 FROM MAIN MIl I
(v)
1-1302-V4-002           _    l-1302-V4-001                                         gy                                MM UMM                                           I
M II 2.5' PV HV NM CONDENSATE CONDENSATE TE 15129 5106 MIl STORAGE TANK STORAGE TANK 5175 FROM MAIN I
                                                                                ,@                                                                              gg3)(ggg) D 15133         SI           HS OMCB                  g                 2'5'!!
1-1302-V4-002 l-1302-V4-001 MM UMM I
HV                                     5109             106A                   5107 6   - 5090           5110A                                               MCB                   -
gy gg3)(ggg) D 15133 OMCB SI HS g
6'         m       l I LO                                ,.
2'5'!!
I N                   %
HV 5109 106A 5107 6 - 5090 5110A MCB l
9                               HV s
LO I
AUX FEEDVATER sJ                TURBINE DRIVEN                           y b
6' m
                                                                                                                                                                      -                   =                  ,
I N
HV    5093                                                                                            " N                              NDE THIS IS A 1-hoY-P NkkOf                                            X ti[
s s J
s_ _
=
If 5113 ATMOSPHERE TO             FEEDVATE PUMP              FV
9 HV AUX FEEDVATER TURBINE DRIVEN y b 1-hoY-P NkkOf N
[-                   SIMPLIFIED DIAGRAM USED TO DEPICT A TEST 10, i                                                          MCB                         5154                                           CIRCUIT. REFER TO THE OMCB                   H                                                                                                   ^
NDE THIS IS A HV 5093 ti[
                                                          'D     g                                           l3 A                                                               AMMONIA 8.
5113 TO FEEDVATE
[-
X s__
SIMPLIFIED DIAGRAM If ATMOSPHERE PUMP FV USED TO DEPICT A TEST 10, MCB 5154 CIRCUIT. REFER TO THE i
OMCB H
'D g
l3 A
^
S]
S]
HV                           S   HV                               128                                       MCB                                     HYDRAZINE 09            5094                                                          ,                4,                          @        g          g g[_5098
AMMONIA 8.
_s_                                l[8'                   e       8'                                                                       ll:       N                 y HV                           i U                                                                             h 5118                                FE g TER                                                                             3   -
HV S
2' 8"         '
HV 128 MCB HYDRAZINE g[_5098 5094 g
QMCB HV QMCB                               M                                             2~
g l[8' 09 4,
5095                                    D HV                 --
e 8'
            -                                HV             LO               1-     02-P4-003 5119                                         AUX 8,                             G        8, FEEDVATER PUMP
ll:
    ,EW.         EM         M   M1                           m3cygpygge                     appgj   sppeg   appg3 apea4     APPt 3   M3taPK$
N y
e         s-a-=     nas   vs       num run m                                         ti i         1-e++.         en       wmns = imma4 =v i.                               Jac
_s_
        *                  ~               ~~"~
h HV i
Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT ==* "                           n=*   *ac UNIT 1                 ""*                  === vs
U FE g TER 3
                                                                                                                                                                                  ~ ~
2' 5118 8"
PUMP INSERVICE TESTING LOOP FOR AUXILLARY FEEDVATER PUMP
QMCB QMCB M
: a. 52Y            m, j                1-1302-P4-002                N/A        N/A    ISl-D- 224    1 IT 1 2
2~
HV D
HV 5095 HV LO 1-02-P4-003 5119 AUX G
FEEDVATER 8,
8, PUMP
,EW.
EM M
M1 m3cygpygge appgj sppeg appg3 apea4 APPt 3 M3taPK$
e s-a-=
nas vs num run m ti i
1-e++.
en wmns = imma4 =v i.
Jac
~
~~"~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT==* "
n=*
*ac UNIT 1


[]                                                                                                                                 N                                                                                                                                                            'N, U                                                                                                                           {V                                                                                                                                               (V Ap                                                                                                                 ::                        ,
=== vs
                                                                                                                                                                                                          @                                                                            a.s-N CONDENSATE                                                                  TC                                    15 29                                                                                    I                                             2.5
~ ~
* CONDENSATE                                                                                             510                                                                     l STORAGE TANK             STORAGE TANK                                   5175                                                                     FRDN MAIN                                                       I 1-1302-V4-002             1-1302-V4-001                                                                                                             NAMUSEM                                                        101 sy                                                                 ggg)g       0 l
PUMP INSERVICE TESTING LOOP 52Y m,
HV 15133     gg         gg             -DMCB                           'M                         2.5'!!                             .
a.
5109       106A                   5107 o--     5090       5110A                                                             MCB                   -
FOR AUXILLARY FEEDVATER PUMP j
J                        GMCB                                       /,                                   R ru            l LO    0%                                         ,
1-1302-P4-002 N/A N/A ISl-D-224 1 IT 1 2
i             6'                               i                                                                                                                                               ;
 
a                             'N                                                                         am                   e                                                                       '
[]
HV       AUX FEEDVATER                                     TURBINE DRIVEN                                   b b 3[-@0 M
U
5113 HV      5093        PUMP TURBIN 1-1302-P4-001 E K01'TD ATMOSPHERE l-1302-P4-001 FEKD RUMP  ATER ry N  (V
{V (V
N
'N, Ap a.s-N I
2.5
* CONDENSATE CONDENSATE TC 15 29 510 l
STORAGE TANK STORAGE TANK 5175 FRDN MAIN I
NAMUSEM 101 1-1302-V4-002 1-1302-V4-001 sy ggg)g l
0 15133 gg gg
-DMCB
'M 2.5'!!
HV 5109 106A 5107 o-- 5090 5110A MCB J
GMCB
/,
R l
0%
i 6'
ru i
LO a
'N am e
3[-@0 HV AUX FEEDVATER TURBINE DRIVEN b b PUMP TURBIN l-1302-P4-001 N
(V NGTO THIS IS A HV 5093 1-1302-P4-001 EK01'TD FEKD ATER
[-
[-
NGTO THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST I
5113 SIMPLIFIED DIAGRAM M
p
ATMOSPHERE RUMP ry USED TO DEPICT A TEST I
                                                                                                @              GMCB 130A M140                                                7' r mj AMMONIA &
GMCB M
D          OR D TAI .
7' D
HV                             ~~o                 HV                                               128                                 MCB                                       8 '' HYDRAZINE
OR D TAI.
                                                                                    ' 5094                                                                                                                             6         g           6 O f_ 5098                                           8'         ,
r p
e'                                                                                       lIl                 N HV                                LD (05E)       1-130g4-002                                                                                                     g 5118                                                 FEggTER                                                                                                       e-                 2*
130A 140 mj AMMONIA &
: g.                                   N                                                                                                    5155                       ?   <
HV
HV l S'                                                               QMC                                                                       3 QMC                                   HS               pg                                                 ,2' -
~~o HV 128 MCB 8
5092--S                         5095 HV 5129 131A           5141A                                                 (l 0 s U
'' HYDRAZINE
6 O_                                       HV                                   LO         j{ 1- 02-P4-003 5119                                                       AUX g,                                             @    s 8,       FEEDVATER PUMP "v-           we           ,,  ..,                                            MSCRIPTEBe O             S 4 4-94   g;g 4M4 TV I6 B
' 5094 6
                                                                                                                                        =
g 6
Southern Company Services, Inc.roR Southern Nuclear Operating Company VDGTLE ELECTR                   ENERATING PLANT                             "                                  ""
O f_ 5098 8'
Q88a
e' lIl N
                                                                                                                                                                                                                                                ~
LD (05E) 1-130g4-002 g
PUMP INSERVICE TESTING LOOP                                                                 . .au.       $$                                                      oui             uv.
HV 5118 FEggTER e-2*
FOR AuxlLLARY FEEDVATER PUMP 1-1302-P4-003                                 N/A                                   N/A     ISI 225                                             1T1 2
N g.
5155
?
l S' 3
QMC HV QMC HS pg
,2' 5092--S 5095 HV 131A 5141A
( l U 5129 s
6 0
O_
HV LO j{ 1-02-P4-003 5119 AUX g,
8, FEEDVATER s
PUMP "v-we MSCRIPTEBe O
S 4 4-94 g;g 4M4 TV I6 B
=
Southern Company Services, Inc.roR Southern Nuclear Operating Company VDGTLE ELECTR ENERATING PLANT Q88a PUMP INSERVICE TESTING LOOP
~
.au.
oui uv.
FOR AuxlLLARY FEEDVATER PUMP 1-1302-P4-003 N/A N/A ISI 225 1T1 2


l ESF Pumps                                                           \
ESF Pumps
\\
i (1-1592-P7-001, & 002)
i (1-1592-P7-001, & 002)
O                 System Function
O System Function i
                                                  ~
~
Durmg normal operation, the ESF chilled-water system is in l
Durmg normal operation, the ESF chilled-water system is in standby mode; it is activated during emergency conditions upon receipt of a safety injection signal, containment ventilation isolation, or control room isolation signal. The ESF chilled-water system serves air handling units located in the safety-related areas of the plant to ensure the l
i standby mode; it is activated during emergency conditions upon receipt of a safety injection signal, containment ventilation isolation, or control room isolation signal. The ESF chilled-water system serves air handling units located in the safety-related areas of the plant to ensure the integrity of the cooling system during plant emergency l                                                            situation.                                                               '
integrity of the cooling system during plant emergency situation.
l l                     Quantity                               2 1
l l
Type                                   Centrifugal Manufacturer                           Goulds Capacity                               600 gpm Total Dynamic Head                     125 ft.
Quantity 2
Driver .
1 Type Centrifugal Manufacturer Goulds Capacity 600 gpm Total Dynamic Head 125 ft.
l                           Type                             Westinghouse electric motor i                           Horsepower                       30 iO                         sPeea Power Supply tioo rP-480V,60 Hz,3 phase l
Driver.
Code Class                             3 Project Class                           313 Outline Drawing                         IX4AJ05-27 Instmetion Book                       AX4AJ05-86 Physical Location                       Control Bldg, EL 260 ft., Rooms R-313 & R320 i
l Type Westinghouse electric motor i
P&ID                                     IX4DB221 l
Horsepower 30 iO sPeea tioo rP-Power Supply 480V,60 Hz,3 phase Code Class 3
Surveillance Procedure                   14809-1 l                   Pump Test Loop Diagrams                 ISI-D-226 & ISI-D-227 l
l Project Class 313 Outline Drawing IX4AJ05-27 Instmetion Book AX4AJ05-86 Physical Location Control Bldg, EL 260 ft., Rooms R-313 & R320 i
Test Parameter Sheets                   Page 13-2 & 13-3 i
P&ID IX4DB221 Surveillance Procedure 14809-1 l
l4 13 - 1                                 Rev.0
Pump Test Loop Diagrams ISI-D-226 & ISI-D-227 l
                                                                                        -nt
Test Parameter Sheets Page 13-2 & 13-3 i
l 4
13 - 1 Rev.0
-nt


                                                                                                                                                                                                                                  ~
~
i Test Parameter Table - Pump I-1592-P7-001 (Figure ISI-D-226)
i Test Parameter Table - Pump I-1592-P7-001 (Figure ISI-D-226)
Instrumentation Utilized                         Ref.             Acceptable                       Alert                   Action                                                     ;
Instrumentation Utilized Ref.
Parameter           Test Frea.     LD. No.(3)     Bange                     Req. Ace.     Value           Range                             Range                 Range                 Comments Speed (N)                 NA             NA             NA                       NA             NA             NA                               NA                     NA                   Constant speed driver                 ,
Acceptable Alert Action Parameter Test Frea.
i Inlet Pressure             Qtr             PI-22410     0-30                       12%           NA             NA                               NA                     NA                   NA                                   ,
LD. No.(3)
(Pi)                                               psig r
Bange Req. Ace.
Outlet                                                                                                                                                                                                                           ,
Value Range Range Range Comments Speed (N)
Pressure             Qtr           PI-22414       0-200                     12%           NA             NA                               NA                     NA                   NA                     i (Po)                                               psig                                                                                                                                                                           i Differ.
NA NA NA NA NA NA NA NA Constant speed driver i
Pressure             Qtr           NA(1)         NA                         2%           APr             .90 - 1.10APr                     NA                     <.90 or >l.10APr NA
Inlet Pressure Qtr PI-22410 0-30 12%
* k (AP) i Flowrate             Qtr           FI-22425       0-750                     12%           Qr               NA                               NA                     NA                   Flowrate is set at reference value gpm                                                                                                                                                                            i (Q)
NA NA NA NA NA (Pi) psig r
I Vib.
Outlet f
Amp.                 Qtr           (2)           NA                         i5%           Vr               s 2.5Vr                           > 2.5Vr - 6Vr           >6Vr or               NA (V)(4)                                                                                                                                         or >.325 in/s           >.70 in/s                                                 .
Pressure Qtr PI-22414 0-200 12%
l Notes:                                                                                                                                                                                                                           r 6
NA NA NA NA NA i
: 1. Differential pressure is calculated as, AP = Po - Pi                                                                                                                                                                           r
(Po) psig i
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                   !
Differ.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                 ;
Pressure Qtr NA(1)
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                     !
NA 2%
direction on each accessible thrust bearing housing.                                                                                                                                                                         f 13 - 2                                                                                         Rev.0                               j l
APr
,                                                                                                                                                                                                                                  i i
.90 - 1.10APr NA
I                                                                                                                                                                                                                                   i I
<.90 or >l.10APr NA k
(AP) i Flowrate Qtr FI-22425 0-750 12%
Qr NA NA NA Flowrate is set at reference value i
(Q) gpm I
Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s l
[
Notes:
r 6
: 1. Differential pressure is calculated as, AP = Po - Pi r
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
f j
13 - 2 Rev.0 l
i i
I i
I


s i
s i
Test Parameter Table - Pump 1-1592-P7-002 (Figure ISI-D-227)
Test Parameter Table - Pump 1-1592-P7-002 (Figure ISI-D-227)
Instrumentation Utilized             Ref.         Acceptable   Alert         Action Test Freq.                         I.D. No.(3)                 Range         Reg. Acc.       Value         Range         Rance         Range           Comments Parameter Speed NA                               NA                           NA           NA             NA           NA           NA           NA               Constant speed driver (N)
Instrumentation Utilized Ref.
Inlet PI-22411                   0-30         i2%             NA           NA           NA           NA               NA Pressure            Qtr (Pi)                                                                               psig Outlet Pressure                                               PI-22415                   0-200         12%             NA           NA           NA           NA               NA Qtr (Po)                                                                               psig Differ.
Acceptable Alert Action Parameter Test Freq.
Pressure           Qtr                               NA(1)                       NA           i2%             APr           .90 - 1.10APr NA           <.90 or >l.10APr NA (AP)
I.D. No.(3)
Flowrate           Qtr                                 FI-22426                   0-750         i2%             Qr           NA           NA           NA               Flowrate is set at reference value (Q)                                                                               gpm Vib.
Range Reg. Acc.
Amp.               Qtr                               (2)                         NA           i5%             Vr           s 2.5Vr       > 2.5Vr- 6Vr >6Vror           NA
Value Range Rance Range Comments Speed (N)
!                                                                                                                                              or >.325 in/s >.70 in/s (V)(4)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-22411 0-30 i2%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-22415 0-200 12%
NA NA NA NA NA (Po) psig Differ.
Pressure Qtr NA(1)
NA i2%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr FI-22426 0-750 i2%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr-6Vr
>6Vror NA or >.325 in/s
>.70 in/s (V)(4)
Notes:
Notes:
: 1. DifTerential pressu.~ is calculated as, AP = Po - Pi
: 1. DifTerential pressu.~ is calculated as, AP = Po - Pi
Line 1,810: Line 3,675:
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
13 - 3                                                   Rev.0
13 - 3 Rev.0


(
(
J'                                                                                             v                                                                                                                                                                         V NOTE 1. THIS IS A SIMPLIFIED EXPANSION                                                                                                                                                                                                       DIAGRAM USED TO DEPICT TANK HVC                                                                                                                                                A TEST CIRCUIT. REFER S       1-1592-T7-001                                                                                                                                                                                                     TO THE P8.ID FOR 2240                                                               IP2412                                                                                                                                                     DETAILS.
J' v
2240 C
V NOTE
I,                                               (                                             IA
: 1. THIS IS A SIMPLIFIED EXPANSION DIAGRAM USED TO DEPICT TANK A TEST CIRCUIT. REFER HVC S
: 2. VALVE INTERNALS REMOVED PER DCP
1-1592-T7-001 TO THE P8.ID FOR 2240 IP2412 DETAILS.
                                                                            }                                                                                                 pO .                                                                                               90-VIN 0067-0-1 f
C 2240 I,
D        ,
(
CHEMICAL
: 2. VALVE INTERNALS REMOVED PER DCP IA
                                                                                                    . FEED POT.
}
SDA                                                                                                                                           TI 242 FI mgamn,,
pO.
N2 t'' S                                                                                                                                                   ,,          ,
90-VIN 0067-0-1 f
(U5tD                    GMD                                                                                              PI                                                   HV           TI                                                                             243 '     244 pI 2241     e                                         2244           2241 22410                                                                                                                                                                                   '
. FEED POT.
3J L
242 CHEMICAL SDA TI FI D
                                          @ 3,                                                                                           1/2"                                             l LC                      O                         N                                                                                                                                                                                           !    #
mgamn,,
N                                               l                                                   EVAP. l M                                                           @ CB ESF CHILLER                                                                                           '
t'' S N2 PI HV TI 243 '
k        ATER                        h, I' r
244 (U5tD GMD pI 2241 e
LC 2"   6'               n 5
2244 2241 22410 3J L
odL 1P CB ESF CHILLED VATER PUMP 1-1592-C 7-001-000 HV                     1-1592-P7-001-000 240                     PROJ. CLASS 313 10'                         ,                                                                                                                                                                                                    i t 10*     10'
@ 3, 1/2" l
                                                              ~
O N
_                                            TRAIN 'A'                                                                                                                             6' CDOLING COILS
LC N
=~. ==        s,    .                              === rs=                    -u      w.,          .    .  -s  -
l EVAP. l M
9    +H        BW  WS              I3$tES FIR PST                                  I we+=        :  ews              woms a u.saans arv n                      -  JC E
@ CB ESF CHILLER k
i7          .                  C ,,1"              '
1-1592-C 7-001-000 h, I' CB ESF CHILLED 2"
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT ==* "                                                                                                                            =    *a UNIT I                                                              '"*                                                                            o=*    vs PUMP INSERVICE TESTING LOOP FOR CB ESF CHILLED WeiCo PUMP
6' n
                                                                                                                                                                                                                                    ".                                                $ $ 2 '          ,,    .
ATER 1P 5
TRAIN 'A' 1-1592-F 7-001-000                                                    N/A                                                            N/A        ISI-D- 226    1 IT I 3
VATER PUMP r
LC HV odL 1-1592-P7-001-000 240 PROJ. CLASS 313 10' i t 10*
10'
~
TRAIN
'A' 6'
CDOLING COILS
?
=~.


v                                                                                                 v                                                                           (
==
s,
 
=== rs=
-u w.,
-s 9
+H BW WS I3$tES FIR PST I
we+=
ews woms a u.saans arv n
- JC i7 E
C,,1" Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT==* "
=
*a UNIT I o=*
vs PUMP INSERVICE TESTING LOOP
$ $ 2 '
FOR CB ESF CHILLED WeiCo PUMP TRAIN
'A' 1-1592-F 7-001-000 N/A N/A ISI-D-226 1 IT I 3
 
(
+
v v
u>
u>
                                                                                                                                                                                                    +
l NOTE: 1. THIS IS A SIMPLIFIED EXPANSION DIAGRAM USED TO DEPICT TANK A TEST CIRCUIT. REFER HVC S
l NOTE: 1. THIS IS A SIMPLIFIED EXPANSION                                                                                                             DIAGRAM USED TO DEPICT TANK                                                                                                               A TEST CIRCUIT. REFER             '
1-1592-T7-002 TO THE P8.ID FOR 2240 2413 DETAILS.
S          1-1592-T7-002                                                             HVC                                            TO THE P8.ID FOR 2240                                                                               2413                                                 DETAILS.
C
C                                                                                                                                                     2. VALVE INTERNALS l'
: 2. VALVE INTERNALS 22401 l'
22401                                                                                                                                                        REMOVED PER DCP CHEMICAL 90-VIN 0067-0-I j        {n  g                                                                       FEED PDT.             pg f
REMOVED PER DCP CHEMICAL j
D         ,
{n 90-VIN 0067-0-I g
N 7' CHEMICAL FEED PDT.
FEED PDT.
SDB                                      TI 243 FI
pg f
                                                                                                                                                                                            ' 242 s h mn.                           1 C9                                                    ,,            ,,
N CHEMICAL SDB TI FI D
G           G                                                                               PI                             22 1     h  P     44   d 1 22411                                       &L M,                                                                                                               1/2" LC                             #1 "N                                                              N        sm      I     IEVAP. l 6               (2U7) CB ESF CHILLED hkh" VATER
FEED PDT.
                                                                                                                                                                        ~ ~         ~
243
1-                           2'   6*                   m                 CB ESF CHILLED
' 242 7'
                              )(                                                           [P                   VATER PUMP LC                                                   HV       3 dk 1-1592-P7-002-000 L1                   240                         PROJ. CLASS 313 10'                                                                                                                                         ' '
s h mn.
I '
C9 1
10                                 Y 10'h                      D b*                                                                                                                      6*
G G
PI h
22 1 P
44 d 1 22411
&L M,
1/2" LC
#1 I
IEVAP. l N
sm "N
6 (2U7) CB ESF CHILLED hkh" VATER CB ESF CHILLED
~ ~
~
1-2' 6*
m
)(
[P VATER PUMP LC HV 3
1-1592-P7-002-000 dk L1 240 PROJ. CLASS 313 10' I '
10'h Y
10 D
b*
TRAIN "B.
TRAIN "B.
COOLING COILS Ev. SAM     BT Det*3                       M EWIPYE3e                   apetJ             mPpg3 APPt3            appts   appt 3   h3 a   7-** ==   evs     urn.ns = in ams arv is                         _   _C M     .,v    NS           "(( 7           '
6*
Southern Company Services, Inc. FOR Southern Nucisar Operating Cornpany VDGTLE ELECTRIC GENERATING PLANT ==* "                           5"'   "58 UNIT 1               '"'                    ""' v5 nau                     amneens a man PUMP INSERVICE TESTING LOOP                       ua           v             .a. = v.
COOLING COILS Ev.
FOR CB ESF CHILLED VATER PUMP TRAIN 'B'   1-1592-P7-002-000       N/A       N/A     ISI-D- 227         I IT I 3
SAM BT Det*3 M EWIPYE3e apetJ APPt3 mPpg3 appts appt 3 h3 a
7-**
 
==
evs urn.ns = in ams arv is
_ _C M
NS
"(( 7 Southern Company Services, Inc. FOR Southern Nucisar Operating Cornpany
.,v VDGTLE ELECTRIC GENERATING PLANT==* "
5"'
"58 UNIT 1
""' v5 nau amneens a man PUMP INSERVICE TESTING LOOP ua v
.a.
= v.
FOR CB ESF CHILLED VATER PUMP TRAIN
'B' 1-1592-P7-002-000 N/A N/A ISI-D-227 I IT I 3


O                                                                                                                                                                                                 O                                                                                                                                                                                                                         O           ,
O O
I t
O I
VEGP-2 PUMP TEST TABLE                                                                                                                                                                                                                                           ,
t VEGP-2 PUMP TEST TABLE i
i Nucle:.r Service Cooling Water - System 1202 LD. Number Measured Per--- :- . A Fr-v                                                                                                                                                               '
Nucle:.r Service Cooling Water - System 1202 Measured Per--- :-. A Fr-v LD. Number CC/PC PalD-Sheet No.
CC/PC   PalD-Sheet No.                                                               Coord.                                                                                                                                   g
Coord.
_ Der 8ation                                                                         h             Q                                               y.                                                           E                                         RIVRemuth (asial     (mull   (aniel ikksi                                                                                         taunl 2-1202-P4-001                               3D13     2X4DB113-1                                                                   C-8                                         NSCW Pump                                                                             Q1R   QTR       Q1R                                           QIR                                                         NA                                       RR-P-2 2-1202-P4-002                                 3D13     2X4DB133-2                                                                   C-8                                           NSCW Pump                                                                           QTR   Q1R       QTR                                           QTR                                                         NA                                         RR-P-2 2-1202-P4-003                               3S13       2X4DB133-1                                                                   C-5                                         NSCW Pump                                                                             QTR     QTR       Q1R                                         QTR                                                         NA                                         ~ RR-P-2 2-1202-P4-004                               3 S 13   2X4DB133-2                                                                   C-5                                         NSCW Pump                                                                           Q1R     QTR       QIR                                         Q1R                                                         NA                                           RR-P-2 2-1202-P4-005                               3B13     2X4DB133-1                                                                   C-7                                       NSCW Pump QTR       QTR     QTR                                         QTR                                                         NA                                             RR-P-2 i
_ Der 8ation h
2-1202-P4 006                               3813       2X4DB133-2                                                                   C-7                                       NSCW Pump                                                                             Q1R       Q1R     Q1R                                       QTR                                                         NA                                             RR-P-2 2-1202-P4@7                                 3013       2X4DB133-1                                                                   C4                                       NSCW Transfer Pump                                                                   Q1R       Q1R     QTR                                       QIR                                                         NA                                             RR-P-2                 !
g Q
2-1202-P4-008                               3B13       2X4DB133-2                                                                   C-6                                     NSCWTransfer Pump 4
y.
QTR       QIR     QTR                                     QTR                                                         NA                                             RR-P-2                   .
E RIVRemuth (asial (mull (aniel ikksi taunl 2-1202-P4-001 3D13 2X4DB113-1 C-8 NSCW Pump Q1R QTR Q1R QIR NA RR-P-2 2-1202-P4-002 3D13 2X4DB133-2 C-8 NSCW Pump QTR Q1R QTR QTR NA RR-P-2 2-1202-P4-003 3S13 2X4DB133-1 C-5 NSCW Pump QTR QTR Q1R QTR NA
t t
~ RR-P-2 2-1202-P4-004 3 S 13 2X4DB133-2 C-5 NSCW Pump Q1R QTR QIR Q1R NA RR-P-2 2-1202-P4-005 3B13 2X4DB133-1 C-7 NSCW Pump QTR QTR QTR QTR NA RR-P-2 i
Test Frequency: QTR= Quarterly Pump Test l
2-1202-P4 006 3813 2X4DB133-2 C-7 NSCW Pump Q1R Q1R Q1R QTR NA RR-P-2 2-1202-P4@7 3013 2X4DB133-1 C4 NSCW Transfer Pump Q1R Q1R QTR QIR NA RR-P-2 2-1202-P4-008 3B13 2X4DB133-2 C-6 NSCWTransfer Pump QTR QIR QTR QTR NA RR-P-2 4
i
t Test Frequency: QTR= Quarterly Pump Test t
                                                                                                                                                                                                                                                                                                                                                                                                                                                                          \
?
l i
\\
r 4
r 4
14 - 1                                                                                                                                                                                               Rev.0 u   _ _ _ _ _ _ _ _ _ . . _ _ _ _ _ _ . _ _ . _ .          ...-m..-___m.a             __-__ . - , * - . _ _ _ _ _ _ ._ _ _ _ _ _ . _ - . _ _ _                                        ______--s                                                                                                                                                                 --_ _ _ _  __-,-=.-%
14 - 1 Rev.0 u
* S ++--wa e-
...-m..-
m.a
--s
__-,-=.-%
S
++--wa e-


  . . _ . .-    ~ . .    .  . . .    . _ _ . - . . . .- - - . . . . .        - . .          - . . . . . -                        _ .        ..-. - _..-... -            .
~..
O O                                                                                               O VEGP-2 PUMP TEST TABLE Component Cooling Water- System 1203 Measured Parameters & Freemency LD. Number         CC/PC       P&ID-Sheet No.                   Coord,       Description                                                                         V Bt       AE           Q                                       N                                                   RR/ Remarks           i (a!ial     fa 0         faunl Gaksl                       framil 2-1203-P4-001       3/313       2X4DB136                           G-4         CCW Pump                                             QTR     QTR           QTR     QTR                             NA                                                 RR-P-2 2-1203-P4-002       3/313       2X4DB136                           D-4         CCW Pump                                             QTR     QTR           QTR     QTR                           NA                                                   RR-P-2 2-1203-P4-003       3/313       2X4DB136                           G-4         CCW Pump                                             QTR     QTR           QTR     QTR                           NA                                                   RR-P-2 2-1203-P4-004       3/313       2X4DB136                         C-4         CCW Pump                                             QTR     QTR             QTR     QTR                           NA                                                   RR-P-2 2-1203-P4-005       3/313       2X4DB136                         F-4         CCW Pump                                               QTR     QTR             QTR     QTR                         NA                                                     RR-P-2 2-1203-P4-006       3/313       2X4DB136                         B-4         CCW Pump                                                                                                                                                                                           '
O O
QTR     QTR           QTR     QTR                         NA                                                     RR-P-2 Test Freepsency: QTR = Qua.terly Pump Test 14 - 2                                                                                                                         Rev.0
O VEGP-2 PUMP TEST TABLE Component Cooling Water-System 1203 Measured Parameters & Freemency LD. Number CC/PC P&ID-Sheet No.
: Coord, Description Bt AE Q
V N
RR/ Remarks i
(a!ial fa 0 faunl Gaksl framil 2-1203-P4-001 3/313 2X4DB136 G-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-002 3/313 2X4DB136 D-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-003 3/313 2X4DB136 G-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-004 3/313 2X4DB136 C-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-005 3/313 2X4DB136 F-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-006 3/313 2X4DB136 B-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 Test Freepsency: QTR = Qua.terly Pump Test L
I L
14 - 2 Rev.0


VEGP-2 PUMP TEST TABLE                                                                                     ;
VEGP-2 PUMP TEST TABLE Safety Injection - System 1204 Measured Parameters & Freenesev LD. NTmber
Safety Injection - System 1204 Measured Parameters & Freenesev LD. NTmber           ((JPC     PAID-Sbret No. Coord. Description h     AP                 Q     V     _N_       RR/ Remarks i
((JPC PAID-Sbret No.
(asis)   (s!Q           (sand hi fouel b
Coord.
2-1204-P6@3           2/212     2X4DB121       E-3   SI Pump                               QTR     QTR               QTR     QTR   NA         RR-P-2 2-1204-P6-004         2/212     2X4DB121       C-3   SI Pump                               QTR     QTR               QTR     QTR   NA         RR-P-2 i
Description h
Test Frequency: QTR = Quarterly Pump Test                                                                                                                           !
AP Q
l t
V
_N_
RR/ Remarks (asis)
(s!Q (sand hi fouel i
b 2-1204-P6@3 2/212 2X4DB121 E-3 SI Pump QTR QTR QTR QTR NA RR-P-2 2-1204-P6-004 2/212 2X4DB121 C-3 SI Pump QTR QTR QTR QTR NA RR-P-2 i
Test Frequency: QTR = Quarterly Pump Test l
t I
I i
I i
14 - 3                                                       Rev.0
14 - 3 Rev.0


O                                                     O                                                                                       O VEGP-2 PUMP TEST TABLE Residual Heat Removal- System 1205 Measured Parameters & Freemency LD. Number         CC/PC       P&ID-Sheet No. Coord. Description             to                                   AE         Q     E     N.         RR/ Remarks (adal                                 fa!!!     (smal Gaksi Ltund 2-1205-P6@l       2/212       2X4DB122       G-4   RHR Pump               QTR                                 QTR         QTR   QTR   NA       RR-P-2 2-1205-P6 @ 2     2/212       2X4DB122       D-4   RHR Pump               QTR                               QTR         QTR   QTR   NA       RR-P-2 i
O O
Test Frequency: QTR = Quarterly Pump Test 14 - 4                                                                       Rev.0
O VEGP-2 PUMP TEST TABLE Residual Heat Removal-System 1205 Measured Parameters & Freemency LD. Number CC/PC P&ID-Sheet No.
Coord.
Description to AE Q
E N.
RR/ Remarks (adal fa!!!
(smal Gaksi Ltund 2-1205-P6@l 2/212 2X4DB122 G-4 RHR Pump QTR QTR QTR QTR NA RR-P-2 2-1205-P6 @ 2 2/212 2X4DB122 D-4 RHR Pump QTR QTR QTR QTR NA RR-P-2 i
Test Frequency: QTR = Quarterly Pump Test 14 - 4 Rev.0


O                                                     O                                                                                                   O VEGP-2 PUMP TEST TABLE Contstment Spray - System 1206                                                                                                                                                                                                 ,
O O
Measured Parnaseters & Freemency LS. N aber         CQ/PC       P&ID-Sheet No. Coord. Description                     Po     R         _Q   V               N                             RR/ Remarks (esial   (e!!1   (and (W=c)       (mal                                                                                                     1 2-12 % % 001       2/212       2X4DB131       G-4   CS Pump                       QTR                                 NA QTR       QTR   QTR                                         RR-P-2                                                               !
O VEGP-2 PUMP TEST TABLE Contstment Spray - System 1206 r
2-12%P6-002         2/212       2X4DB131       C-4   CS Pump                       QTR     QTR                         NA                             RR-P-2 QTR  QTR                                                        ,
Measured Parnaseters & Freemency LS. N aber CQ/PC P&ID-Sheet No.
Test Frequency: QTR = Quarterly Pump Test t
Coord.
r i
Description Po R
l i
_Q V
i 14 - 5                                                                             Rev.0                                                                     >
N RR/ Remarks (esial (e!!1 (and (W=c)
_ _ _ _                __        _ _ _ _ _ _____.__________.__________m_            __..      _ _ _ _ . _ . _ _ _ _ _ _ . _ _        _ _ _ _ . _
(mal 1
2-12 % % 001 2/212 2X4DB131 G-4 CS Pump QTR QTR QTR QTR NA RR-P-2 2-12%P6-002 2/212 2X4DB131 C-4 CS Pump QTR QTR QTR QTR NA RR-P-2 l
l Test Frequency: QTR = Quarterly Pump Test I
t r
i l
i i
14 - 5 Rev.0 m


O                                                                                                                 O                                                                                                                                     O VEGP-2 PUMP TEST TABLE Chemical & Volume Control- System 1208 Measured Parameters & Freemency LD. Number                                                               CC/PC             P&ID-Sheet No. Coord. Description                   Po     AE     Q                                             V-                                     E         RR/ Remarks fa!!al   fasil (sanal (Wwel                                                                           Qaud 2-1208-P6-002                                                           2/212             2X4DBII6-2     G-4       CVCS Centnfugal               QTR   QTR     QTR                                         QTR                                       NA       RR-P-2                                         ,
O O
Charging Pump s
O VEGP-2 PUMP TEST TABLE l
1                2-1208-P6403                                                           2/212               2X4DBII6-2     C-4       CVCS Centrifugal               QTR   QTR     QTR. QTR                                                                               NA       RR-P-2 Charging Pump 2-1208-P6-006                                                           3/313               2X4DBil8       D-4       CVCS Boric Acid QTR   QTR     QTR                                       QTR                                       NA       RR-P-1, RR-P-2                                 -
Chemical & Volume Control-System 1208 f
Transfer Pump 2-1208-P6407                                                         3/313                 2X4DBil8       B-4       CVCS Boric Acid               QTR     QTR   QTR                                       QTR                                         NA       R. P-1, RR-P-2 Transfer Pump Test Frequency: QTR = Quarterly Pump Test I
Measured Parameters & Freemency I
14 - 6                                                                                                                     Rev.O                                               "
LD. Number CC/PC P&ID-Sheet No.
Coord.
Description Po AE Q
V-E RR/ Remarks I
fa!!al fasil (sanal (Wwel Qaud 2-1208-P6-002 2/212 2X4DBII6-2 G-4 CVCS Centnfugal QTR QTR QTR QTR NA RR-P-2 Charging Pump s
2-1208-P6403 2/212 2X4DBII6-2 C-4 CVCS Centrifugal QTR QTR QTR. QTR NA RR-P-2 l
1 Charging Pump 2-1208-P6-006 3/313 2X4DBil8 D-4 CVCS Boric Acid QTR QTR QTR QTR NA RR-P-1, RR-P-2 Transfer Pump 2-1208-P6407 3/313 2X4DBil8 B-4 CVCS Boric Acid QTR QTR QTR QTR NA R. P-1, RR-P-2 Transfer Pump Test Frequency: QTR = Quarterly Pump Test i
I 14 - 6 Rev.O


O                                                                                       O                                                   O i
O O
O i
VEGP-2 PUMP TEST TABLE i
VEGP-2 PUMP TEST TABLE i
Armili;ry Feedwater -System 1302                                                                                                                                                                     i Measured Parameters & Freemency
Armili;ry Feedwater -System 1302 i
* LD. Number                                       CC/PC               P&ID-Sheet No.       Coord.         Descdotion                       Po     R         Q     V     N       RR/ Remarks fadal   te!Q     fand (W=) trustl                         ;
Measured Parameters & Freemency LD. Number CC/PC P&ID-Sheet No.
2-1302-P4-001                                     3/313               2X4DB161-2           F-6             AFW Pump                         QTR   QTR       QTR   Q1R   NA     RR-P-2             I Turbine Driven                                                                               <
Coord.
t 2-1302-P4-002                                     3/313               2X4DB161-2           D-6           AFW Pump                         Q1R   Q1R       Q1R   Q1R   NA     RR-P-2             )
Descdotion Po R
Motor Driven 2-1302-P4-003                                     D 3                 2X4DB161-2           B-6         AFW Pump                           Q1R   QTR                     NA     RR-P-2 QTR    Q1R Motor Driven i
Q V
N RR/ Remarks fadal te!Q fand (W=)
trustl 2-1302-P4-001 3/313 2X4DB161-2 F-6 AFW Pump QTR QTR QTR Q1R NA RR-P-2 I
Turbine Driven t
2-1302-P4-002 3/313 2X4DB161-2 D-6 AFW Pump Q1R Q1R Q1R Q1R NA RR-P-2
)
Motor Driven 2-1302-P4-003 D 3 2X4DB161-2 B-6 AFW Pump Q1R QTR QTR Q1R NA RR-P-2 Motor Driven i
i I
i I
Test Frequency: QTR = Quarterly Pump Test                                                                                                                                                                 :
Test Frequency: QTR = Quarterly Pump Test i
i f
f i
i t
t 14 - 7 Rev.0
14 - 7                                               Rev.0


[
[
VEGP-2 PUMP TEST TABLE Sdety Related (ESF) Chillers - Systens 1592 Measured Parameters & Frea=*=ev LD. Number         CC/PQ         P&ID-Sheet No. Coord.       Descdotion                                                             Po                 AE   Q   V     N         RR/ Remarks (eds!                 (ann (cral h) Its!n1 2-1592-P7-001       3/313         2X4DB221       F-5           ESF Chilled Water                                                     QTR                 QTR   QTR QTR   NA       RR-P-2 Pump 2-1592-P7 002     3/313         2X4DB221       C-5         ESF Chilled Water                                                     QTR                 Q1R QTR   QTR NA         RR-P-2     i Pump Test Frequency: QTR = Quarterly Pump Test                                                                                                                                                                               t i
VEGP-2 PUMP TEST TABLE Sdety Related (ESF) Chillers - Systens 1592 Measured Parameters & Frea=*=ev LD. Number CC/PQ P&ID-Sheet No.
l i
Coord.
14 - 8                                                                                   Rev.0
Descdotion Po AE Q
V N
RR/ Remarks (eds!
(ann (cral h)
Its!n1 2-1592-P7-001 3/313 2X4DB221 F-5 ESF Chilled Water QTR QTR QTR QTR NA RR-P-2 Pump f
2-1592-P7 002 3/313 2X4DB221 C-5 ESF Chilled Water QTR Q1R QTR QTR NA RR-P-2
{
i Pump Test Frequency: QTR = Quarterly Pump Test t
i l
i i
14 - 8 Rev.0


j-                                                                                           NSCW Pumps i
j-NSCW Pumps (2-1202-P4-001, 002, 003, 004, 005, & 006) i i r System Function Provide cooling water for the containment coolers, control building essential chiller condensers, various engineered safety feature pump motor and lube oil coolers, and the component cooling water and auxiliary component cooling water diesel generator jacket water heat exchangers and transfers the heat removed to the ultimate heat sink.
(2-1202-P4-001, 002, 003, 004, 005, & 006) i r                       System Function Provide cooling water for the containment coolers, control building essential chiller condensers, various engineered safety feature pump motor and lube oil coolers, and the component cooling water and auxiliary component cooling water diesel generator jacket water heat exchangers and transfers the heat removed to the ultimate heat sink.
Quantity 6
Quantity                                                   6 Type Vertical Line Shaft,2 stage, selflubricated Manufacturer /Model                                         BinghamMdlamette/18x27B VCM Rated Capacity 8600 gpm (each)
Type Vertical Line Shaft,2 stage, selflubricated Manufacturer /Model BinghamMdlamette/18x27B VCM Rated Capacity 8600 gpm (each)
Rated TotalDynamic Head                                     230 feet Driver Type Electric Motor Horsepower                                             700 Speed                                                 1180 rpm Power Supply O
Rated TotalDynamic Head 230 feet Driver Type Electric Motor Horsepower 700 Speed 1180 rpm Power Supply O
4160V,60 Hz,3 phase Code Class                                                 3 Project Class                                               313 Outline Drawing                                             2X4AF02-33 i
4160V,60 Hz,3 phase Code Class 3
Instmetion Book                                             2X4AF02-94 Physical Location NSCW Pump House P&ID 2X4DB133-1, -2 Surveillance Procedure                                     14802-2 Pump Test Loop Diagrams                                   ISI-D-250 through ISI-D-255                                               !
Project Class 313 Outline Drawing 2X4AF02-33 i
1 Test Parameter Sheets                                     Page 15-3 through 15-8 O
Instmetion Book 2X4AF02-94 Physical Location NSCW Pump House P&ID 2X4DB133-1, -2 Surveillance Procedure 14802-2 Pump Test Loop Diagrams ISI-D-250 through ISI-D-255 1
15 - 1                                 Rev.O
Test Parameter Sheets Page 15-3 through 15-8 O
15 - 1 Rev.O


NSCW Transfer Pumps j
NSCW Transfer Pumps j
(2-1202-P4-007, 008)
(2-1202-P4-007, 008)
{
{
i                     System Function Provides capability to transfer water between cooling tower       )
i System Function Provides capability to transfer water between cooling tower
;                                                                  basins.
)
J                                                                                                                                     l Quantity                                   2 j                       Type Vertical Line Shaft,2 stage, selflubricated i                       Manufacturer /Model                       Bingham-Willamette/18x12A VCM Rated Capacity                             600 gpm (each) l                       Rated Total Dynamic Head                   110 feet Driver
basins.
;                                Type                             Electric Motor Horsepower                                                                                           j 30 j
J Quantity 2
Speed                             1765 rpm i
j Type Vertical Line Shaft,2 stage, selflubricated i
Power Supply                     480V,60 Hz,3 phase
Manufacturer /Model Bingham-Willamette/18x12A VCM Rated Capacity 600 gpm (each) l Rated Total Dynamic Head 110 feet Driver Type Electric Motor j
;                                                                                                                                    l
Horsepower 30 j
;                      Code Class                                 3
Speed 1765 rpm i
{p
Power Supply 480V,60 Hz,3 phase l
* Project Class                             313 s                                                                                                                                     j I
Code Class 3
I Outline Drawing                           2X4AF02-136 i
!{p Project Class 313 s
i                     Instruction Book                           2X4AF02-96
j I
;                      Physical Location                         NSCW Pump House i
Outline Drawing 2X4AF02-136 i
P&ID                                       2X4DB133-1, -2
i Instruction Book 2X4AF02-96 l
.                                                                                                                                    i i                                                                                                                                    l Surveillance Procedure                     14801-2                                                           ,
Physical Location NSCW Pump House i
Pump Test Loop Diagrams                   ISI-D-256 and ISI-D-257 Test Parameter Sheet                     Page 15-9 and 15-10 0
P&ID 2X4DB133-1, -2 i
15 - 2                                     Rev.0
Surveillance Procedure 14801-2 Pump Test Loop Diagrams ISI-D-256 and ISI-D-257 Test Parameter Sheet Page 15-9 and 15-10 0
15 - 2 Rev.0


O                                                                                                                           O                                                                                                                                                         3 Test Parameter Table - Pump 2-1202-P4-001 (Figure ISI-D-250) ~
O O
Instrumentation Utilized               Ref.                                                           Acceptable                                                                                 Alert         Action Earameter           Test Frea.     I.D. NoJ4)     Range               Req Acc. Value                                                           RanFe                                                                                     Range         Range           Comments Speed (N)                 NA             NA             NA                   NA       NA                                                             NA                                                                                         NA           NA               Constant speed driver Inlet-Pressure           Qtr             LI-1606         NA                 (1)       NA                                                             NA                                                                                         NA           NA               Measure basin level (Pi)
3 Test Parameter Table - Pump 2-1202-P4-001 (Figure ISI-D-250) ~
Outlet Pressure           Qtr             PI-2148         0-200             12%       NA                                                             NA                                                                                         NA           NA               NA                     i (Po)                                               psig DifTer-Pressure           Qtr             (2)             NA                 i2%       APr                                                           .95 - 1.10APr                                                                               .93 - <.95APr <.93 or >l.10APr NA (AP)
Instrumentation Utilized Ref.
Flowrate           Qtr             FI-l 1760       0-15000           12%       Qr                                                             NA                                                                                         NA           NA               Flowrate is set at reference value (Q)                                                 gpm Vib.
Acceptable Alert Action Earameter Test Frea.
Amp.               Qtr             (3)             NA                 15%       Vr                                                             s 2.5Vr                                                                                     > 2.5Vr - 6Vr >6Vr or         NA                                   '
I.D. NoJ4)
(V)(5)                                                                                                                                                                                                                                       or >.325 in/s >.70 in/s i
Range Req Acc.
Value RanFe Range Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet-Pressure Qtr LI-1606 NA (1)
NA NA NA NA Measure basin level (Pi)
Outlet Pressure Qtr PI-2148 0-200 12%
NA NA NA NA NA i
(Po) psig DifTer-Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr FI-l 1760 0-15000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA 15%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s i
Notes:
Notes:
i
i
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                 ;
: 3. Portable vibration instruments are utilized.
: 4. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                                                                                               ,
: 4. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.                                                                                                                                                                               j i
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
15 - 3                                                                                                                                                                                   Rev.0                               !
j i
i r
I 15 - 3 Rev.0 i
r


O                                                                                                                                         O                                                                                                                                                                                             O                 i Test Parameter Table - Pump 2-1202-P4-002 (Figure ISI-D-251)
O O
Instrumentation Utilized                                                               Ref.       Acceptable                                 Alert                                                                                                     Action Parameicr         Test Frea,             I.D. No14)         Range                                           Reo. Acc.                       Value     Range                                     Range                                                                                                     Range           Cnements Speed (N)                 NA                     NA                 NA                                             NA                               NA       NA                                       NA                                                                                                         NA               Constant speed driver Inlet Pressure           Qtr                   LI-1607             NA                                             (1)                             NA       NA                                       NA                                                                                                         NA               Measure basin level (Pi)                                                                                                                                                                                                                                                                                                                                                                 l Outlet                                                                                                                                                                                                                                                                                                                                                               >
O i
Pressure           Qtr                   PI-2149             0-200                                         12%                             NA       NA                                       NA                                                                                                         NA               NA                     i (Po)                                                           psig Differ.
Test Parameter Table - Pump 2-1202-P4-002 (Figure ISI-D-251)
Pressure           Qtr                 (2)                 NA                                             i2%                               APr       .95 - 1.10APr                           .93 <.95APr                                                                                                 <.93 or >l.10APr NA (AP)                                                                                                                                                                                                                                                                                                                                                                 ;
Instrumentation Utilized Ref.
Flowrate           Qtr                 FI-I 1763           0-15000                                       12%                               Qr       NA                                     NA                                                                                                           NA               Flowrate is set at reference value (Q)                                                           gpm Vib.
Acceptable Alert Action Parameicr Test Frea, I.D. No14)
Amp.               Qtr                 (3)                 NA                                             i5%                               Vr       s 2.5Vr                               > 2.5Vr - 6Vr                                                                                                 >6Vr or         NA                                   t (V)(5)                                                                                                                                                                                         or >.325 in/s                                                                                                 >.70 in/s Notes:
Range Reo. Acc.
Value Range Range Range Cnements Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1607 NA (1)
NA NA NA NA Measure basin level (Pi)
}
l Outlet Pressure Qtr PI-2149 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr FI-I 1763 0-15000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA t
(V)(5) or >.325 in/s
>.70 in/s Notes:
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
Line 1,984: Line 4,011:
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
i 15 - 4                                                                                                                                                                         Rev.0 i
i 15 - 4 Rev.0 i


O                                                                                 O                                                                     O Test Parameter Table - Pump 2-1202-P4-003 (Figure ISI-D-252)                                                                               !
O O
Instrumentation Utilized               Ref.     Acceptable   Alert         Action Parameter                     Test Frea. I.D. No.(4)               Range   Rea. Acc. Value     Ranee       Range         Range               Comments Speed (N)                           NA         NA                         NA       NA       NA       NA           NA             NA                 Constant speed driver Inlet                                                                                                                                                                                     ,
O Test Parameter Table - Pump 2-1202-P4-003 (Figure ISI-D-252)
Pressure                     Qtr       LI-1606                   NA       (1)       NA       NA.           NA             NA                 Measure basin level (Pi)
Instrumentation Utilized Ref.
Outlet Pressure                     Qtr       PI-2152                   0-200   12%       NA       NA           NA             NA                 NA                 .
Acceptable Alert Action Parameter Test Frea.
(Po)                                                               psig Differ.                                                                                                                                                                                   ;
I.D. No.(4)
Pressure                     Qtr       (2)                       NA         2%     APr       .95 - 1.10APr .93 <.95APr   <.93 or >l.10APr NA (AP)                                                                                                                                                                                     .
Range Rea. Acc.
Flowrate                     Qtr       FI-I1762                   0-15000 12%       Qr       NA           NA           -NA                 Flowrate is set at reference value (Q)                                                                 gpm Vib.
Value Ranee Range Range Comments Speed (N)
Amp.                         Qtr       (3)                       NA       i5%       Vr       5; 2.5Vr     > 2.5Vr - 6Vr >6Vr or           NA (V)(5)                                                                                                         or >.325 in/s >.70 in/s Notes:
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1606 NA (1)
NA NA.
NA NA Measure basin level h
(Pi)
Outlet Pressure Qtr PI-2152 0-200 12%
NA NA NA NA NA (Po) psig Differ.
Pressure Qtr (2)
NA 2%
APr
.95 - 1.10APr
.93 <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr FI-I1762 0-15000 12%
Qr NA NA
-NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA i5%
Vr 5; 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s Notes:
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.
: 3. Portable vibration instruments are utilized.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                         !
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
15- 5                                                     Rev.0
15-5 Rev.0
                                                                                                                                                                                        .I
.I


O                                                                           O                                                                         O Test Parameter Table - Pump 2-1202-P4-004 (Figure ISI-D-253)
O O
Instrumentation Utilized             Ref.         Acceptable   Alert             Action Parametgr         Test Freq.       I.D. No14)     Range         Reo. Acc. Value       Bange         Range             Range             Comments Speed (N)                 NA             NA             NA             NA           NA           NA             NA               NA                 Constant speed driver Inlet Pressure           Qtr             LI-1607       NA             (1)         NA         NA             NA               NA                 Measure basin level (Pi)
O Test Parameter Table - Pump 2-1202-P4-004 (Figure ISI-D-253)
Outlet Pressure           Qtr             PI-2153         0-200         12%         NA           NA             NA               NA                 NA                 ,
Instrumentation Utilized Ref.
(Po)                                               psig Differ.
Acceptable Alert Action Parametgr Test Freq.
Pressure           Qtr             (2)             NA             i2%         APr         .95 - 1.10APr .93 - <.95APr     <.93 or >l.10APr NA (AP)
I.D. No14)
Flowrate           Qtr             FI-l 1765       0-15000       12%         Qr           NA             NA               NA                 Flowrate is set at reference value (Q)                                                 gpm Vib.
Range Reo. Acc.
Amp.               Qtr             (3)             NA             i5%         Vr           s 2.5Vr       > 2.5Vr - 6Vr     >6Vr or             NA (V)(5)                                                                                                     or >.325 in/s     >.70 in/s Notes:
Value Bange Range Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1607 NA (1)
NA NA NA NA Measure basin level (Pi)
Outlet Pressure Qtr PI-2153 0-200 12%
NA NA NA NA NA (Po) psig Differ.
Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr FI-l 1765 0-15000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s Notes:
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
Line 2,014: Line 4,081:
: 4. At the discretion of SNC, instmmentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. At the discretion of SNC, instmmentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
15 - 6                                                         Rev.0
15 - 6 Rev.0


(3                                                                                                                                                                                                                                                                                                                                           %
(3 G
G                                                                                                                                                                                                                                                                                                                                                     ,
Test Parameter Table - Pump 2-1202-P4-005 (Figure ISI-D-254)
Test Parameter Table - Pump 2-1202-P4-005 (Figure ISI-D-254)
Instrumentation U83H=d                                                                                                                                         Ref.             Acceptable   Alert                     Action Paramelgt             Test Frea.                             LD. No.(4)                                                 Bange                                               Erg. Acc.                                                             Yalue             Range         Ranee                     Bangt           Comments                           !
Instrumentation U83H=d Ref.
Speed (N)                   NA                                     NA                                                         NA                                                   NA                                                                   NA               NA           NA                         NA               Constant speed driver             ;
Acceptable Alert Action e
i Inlet Pressure               Qtr                                     LI-1606                                                   NA                                                 (1)                                                                   NA               NA.           NA                         NA               Measure basin level (Pi)
Paramelgt Test Frea.
Outlet                                                                                                                                                                                                                                                                                                                                                             l Pressure               Qtr                                   PI-2150                                                   0-200                                               12%                                                                   NA                 NA           NA                         NA               NA                 i (Po)                                                                                                                     psig Differ.
LD. No.(4)
Pressure               Qtr                                   (2)                                                       NA                                                   12%                                                                   APr               .95 - 1.10APr .93 - <.95APr             <.93 or >l.10APr NA                                 j i
Bange Erg. Acc.
(AP)                                                                                                                                                                                                                                                                                                                                                               L Flowrate               Qtr                                   F1-11761                                                   0-15000                                             i2%                                                                   Qr                 NA           NA                         NA               Flowrate is set at reference value (Q)                                                                                                                     gpm Vib.
Yalue Range Ranee Bangt Comments Speed (N)
Amp.                   Qtr                                   (3)                                                         NA                                                 i5%                                                                   Vr                 s 2.5Vr       > 2.5Vr - 6Vr             >6Vr or         NA (V)(5)                                                                                                                                                                                                                                                                               or >.325 in/s             >.70 in/s t
NA NA NA NA NA NA NA NA Constant speed driver i
N:tes:
Inlet Pressure Qtr LI-1606 NA (1)
I. Basin level indicator is utilized to determine level in feet.
NA NA.
: 2. Differentishressure is calculated using basin level (to determine suction head) and outlet pressure.                                                                                                                                                                                                                                                             ;
NA NA Measure basin level (Pi) v Outlet l
: 3. Portal % vibrmbn instruments are utilized.                                                                                                                                                                                                                                                                                                                       ,
Pressure Qtr PI-2150 0-200 12%
NA NA NA NA NA i
(Po) psig l
[
Differ.
Pressure Qtr (2)
NA 12%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA j
i (AP)
L Flowrate Qtr F1-11761 0-15000 i2%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s
[
t I
t N:tes:
c I. Basin level indicator is utilized to determine level in feet.
(
: 2. Differentishressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portal % vibrmbn instruments are utilized.
: 4. At '.ne discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. At '.ne discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
15 - 7                                                                     Rev.0
15 - 7 Rev.0 j
_ . - . . . - - _ . - . _ . _ _ _ - - _ . - - _ _ _ - _ - - - . . . - _ . - - - _ - - - _ -                              _-----_--.--_s                      . - - _-  c           w~
l
----- --.-- s c
w~


O Test Parameter Table - Pump 2-1202-P4-006 (Figure ISI-D-255)
O Test Parameter Table - Pump 2-1202-P4-006 (Figure ISI-D-255)
Instrumentation Utilized             Ref.     Acceptable             Alert                                         Action                                                                                             ;
Instrumentation Utilized Ref.
Parameter                     Test Freq.                       I.D. NoJ4)                       Range   Req. Acc. Value     Range                   Range                                         Pange                                                     Comments                                 4 Speed                                                                                                                                                                                                                                                                                                 t (N)                           NA                               NA                               NA     NA       NA       NA                     NA                                             NA                                                       Constant speed driver inlet Pressure                     Qtr                             LI-1607                           NA     (1)       NA       NA                     NA                                           NA                                                         Measure basin level (Pi)                                                                                                                                                                                                                                                                                                   ,
Acceptable Alert Action Parameter Test Freq.
i Outlet Pressure                     Qtr                               PI-2151                         0-200   12%       NA       NA                     NA                                           NA                                                         NA                 i                   ,
I.D. NoJ4)
(Po)                                                                                           psig Differ.
Range Req. Acc.
Pressure                     Qtr                               (2)                             NA       i2%       APr       .95 - 1.10APr           .93 - <.95APr                                 <.93 or >l.10APr NA (AP)
Value Range Range Pange Comments 4
Flowrate                     Qtr                               FI-I1764                         0-15000 12%       Qr       NA                     NA                                           NA                                                         Flowrate is set at reference value       ,
Speed t
(Q)                                                                                             gpm Vib.
(N)
Amp.                         Qtr                               (3)                             NA       i5%.     Vr       s 2.5Vr                 > 2.5Vr - 6Vr                               >6Vr or                                                     NA (V)(5)                                                                                                                                               or >.325 in/s                               >.70 in/s Notes:
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr LI-1607 NA (1)
NA NA NA NA Measure basin level (Pi) i Outlet Pressure Qtr PI-2151 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr (2)
NA i2%
APr
.95 - 1.10APr
.93 - <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr FI-I1764 0-15000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA i5%.
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s Notes:
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
Line 2,050: Line 4,163:
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one ofwhich is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one ofwhich is the axial direction.
i t
i t
15 - 8                                                                                                                                     Rev.O
15 - 8 Rev.O
                                                                                                                                                                                                                                                                                                    \
\\
                                                                                                                                                  -                                                                                                        -  +   -_                ,  , - . + n
+
, -. +
n


O                                                                                                                                                                                       F                                                                                                                                     O               '
O F
Test Parameter Table - Pump 2-1202-P4-007 (Figure ISI-D-256)                                                                                                                                                                                   ;
O Test Parameter Table - Pump 2-1202-P4-007 (Figure ISI-D-256)
Instrumentation Utilized                                             Ref.                                                       Acceptable                                 Alert               Action                                                                           !
Instrumentation Utilized Ref.
Parameter         Test Frea.                         I.D. No.f41                                   Bange                       Rea. Acc. Yalue                                                       Rasse                                     Range               Range                                           Comments Speed (N)               NA                                 NA                                           NA                           NA         NA                                                           NA                                         NA                 NA                                               Constant speed driver inlet Pressure           Qtr                                 LI-1606                                       NA                           (1)       NA                                                           NA                                         M *_               NA                                               Measure basin level (Pi)
Acceptable Alert Action Parameter Test Frea.
Outlet                                                                                                                                                                                                                                                                                                                                                     !
I.D. No.f41 Bange Rea. Acc.
Pressure           Qtr                                 PI-2154                                       0-100                         12%       NA                                                           NA                                         NA                 NA                                             NA                 .
Yalue Rasse Range Range Comments Speed (N)
(Po)                                                                                                 psig i
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr LI-1606 NA (1)
NA NA M *_
NA Measure basin level (Pi)
Outlet Pressure Qtr PI-2154 0-100 12%
NA NA NA NA NA (Po) psig i
Differ.
Differ.
Pressure           Qtr                               (2)                                           NA                             2%     APr                                                           .95 - 1.10APr                             .93 <.95APr       <.93 or >l.10APr NA (AP)
Pressure Qtr (2)
Flowrate           Qtr                               F1-2156                                       0-1000                       12%       Qr                                                           NA                                         NA                 NA                                             Flowrate is set at reference value ,
NA 2%
(Q)                                                                                                 gpm                                                                                                                                                                                                                                                   ,
APr
Vib.
.95 - 1.10APr
Amp.               Qtr                               (3)                                           NA                           15%       Vr                                                           s; 2.5Vr                                   > 2.5Vr - 6Vr     >6Vr or                                         NA (V)(5)                                                                                                                                                                                                                                               or >.325 in/s     >.70 in/s N:tes:                                                                                                                                                                                                                                                                                                                                                       ,
.93 <.95APr
<.93 or >l.10APr NA (AP)
Flowrate Qtr F1-2156 0-1000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (3)
NA 15%
Vr s; 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s N:tes:
i
i
: 1. Basin level indicator is utilized to determine level in feet.                                                                                                                                                                                                                                                                                           '
: 1. Basin level indicator is utilized to determine level in feet.
: 2. DifTerential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. DifTerential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.
: 3. Portable vibration instruments are utilized.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                                                                                                                                             ;
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
15 - 9                                                                                                                                                                   Rev.0 T
15 - 9 Rev.0
.L T


_ _ _ _ _ _ ~ . . - . . .                       . _ _ _ _ _ _ _ _ _ _ _ - _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _                          __ - __-_-__ - - _ __- _____ _ - _ _ _- _ - - _ -- ---_ _ _ _ ____--__-_-_ _ ___-__ _ _ _                                                                    -
_ _ _ _ _ _ ~.. -...
O                                                                                                       O Test Parameter Table - Pump 2-1202-P4-008 (Figure ISI-D-257)                                                                                                                                               !
O O
Instrumentation Utilized               Ref.                                                   Acceptable                             Alert           Action                                               i Paramet-r         Test Freq.                 I.D. No.f 4)                                       RanFe   Req. Ash     Yalu                                                   Range                                 Ranee           Range           Comments Speed (N)                 NA                       NA                                                   NA     NA           NA                                                     NA                                     NA             NA               Constant speed driver               l Inlet                                                                                                                                                                                                                                                                                       ;
Test Parameter Table - Pump 2-1202-P4-008 (Figure ISI-D-257)
Pressure           Qtr                       L1-1607                                             NA     (1)         NA                                                     NA                                     NA             NA               Measure basin level                 ;
Instrumentation Utilized Ref.
(Pi)
Acceptable Alert Action i
Outlet Pressure           Qtr                       PI-2155                                             0-100   12%         NA                                                     NA                                     NA             NA               NA                 i (Po)                                                                                               psig Differ.                                                                                                                                                                                                                                                                                       t Pressure           Qtr                       (2)                                                 NA     i2%         APr                                                   .95 - 1.10.1Pr                         .93 <.95APr     <.93 or >l.103Pr NA                                   l (AP)
Paramet-r Test Freq.
Flowrate           Qtr                       FI-2157                                             0-1000 12%         Qr                                                     NA                                     NA             NA               Flowrate is set at reference value l
I.D. No.f 4)
(Q)                                                                                               gpm Vib.
RanFe Req. Ash Yalu Range Ranee Range Comments Speed (N)
Amp.               Qtr                       (3)                                                 NA       5%         Vr                                                     s 2.5Vr                                 > 2.5Vr - 6Vr   >6Vr or         NA (V)(5)                                                                                                                                                                                                                 or >.325 in/s   >.70 in/s Notes:
NA NA NA NA NA NA NA NA Constant speed driver l
Inlet Pressure Qtr L1-1607 NA (1)
NA NA NA NA Measure basin level (Pi)
Outlet Pressure Qtr PI-2155 0-100 12%
NA NA NA NA NA i
(Po) psig Differ.
t Pressure Qtr (2)
NA i2%
APr
.95 - 1.10.1Pr
.93 <.95APr
<.93 or >l.103Pr NA l
(AP)
Flowrate Qtr FI-2157 0-1000 12%
Qr NA NA NA Flowrate is set at reference value l
(Q) gpm Vib.
Amp.
Qtr (3)
NA 5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(5) or >.325 in/s
>.70 in/s Notes:
: 1. Basin level indicator is utilized to determine level in feet.
: 1. Basin level indicator is utilized to determine level in feet.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
: 3. Portable vibration instruments are utilized.
: 3. Portable vibration instruments are utilized.
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                                                                             ;
: 4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
: 5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.
15 - 10                                                                                                                       Rev.O L                                                                                                                                 _ ._.                                                                                               _          .     -
15 - 10 Rev.O k
                                                                                                                                                                                                                                                                  -                             .--l
L
.--l
 
O O
O NOTE THIS IA A SIMPLIFIED DIAGRAM CV USED TO DEPICT A TEST CIRCUIT.
9446 M[><]H/' ACID ADDITION REFER TO P&lD FOR DETAILS.
(155)
(040) N BLIND FLANGE N
h 142 FC OVDOVN 7
)
I
/
X ylSPERSANT ADDITION s
3'
'048) yy y 4'
a4-h
[6' 18' S
g DMCB g DMCB QMCB 1602A 1608A 1634 18' 18" I
g l
l 11761 l
11762 l
11760 l
1668 NSCVS
. COMPONENTS 24 PDI PI PDI PI PDI PI
,l l
11726 2148 11727 2150 11729 2152 g
HV I I b
1668B 4;rll QKB
-iluri!
' ll
-ilarll N U
/ LIT N O N O
:=
1606 HV HV HV 1160 1160-11600 18'
, TO TGVER TO BASIN N
Ah L
/~\\
/
\\
/ \\
2-1202-P4-001 2-1202-P4-005 2-1202-P4-003 TRAIN
'A' NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-001 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
VATER LOVER i
,c c,
ust.m.
-i ma
-s m-s 77 me ass vi unea m s-a-se as ets ursarts in arv e. y enesm32-t 77C Southern Company Services. Inc.roR Southern Nuclear Operating Company
 
==* "
=*=
8"c V0GTLE ELECTRIC GENERATING PLANT '""
" " ' v5 UNIT 2 PUMP INSERVICE TESTING LOOP FOR
",,an.
$."d i.,
.t NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-001 N/A N/A ISI-D-250 10F 1 2
 
O O
O NOTE: THIS IA A SIMPLIFIED DIAGRAM CV MC)<]l l'/pCID ADDITION USED TO DEPICT A TEST CIRCUIT.
9447 REFER TO THE P8,ID FOR DETAILS.
(049):
@F (077)
BLIND FLANGE g
TO Hl lM TE FC BLOVDOVN g
g
- 1643 1
ISPERSANT ADDITION 7'
(168)
(079)
(078)
S 3*
(050) y y y
[
p h
h h
l OMCB QMCB QMCB I6' 3
18' H
1603A 1609A 1635 j
18' W
I g
g l
11763 b
l 11764 l
11765 1
u g
= p;
-=p 1669 g
g NSCVS g
~~"
~ ~ "
n y,
24. COMPONENTS PDI PI PDI PI PDI PI
.l 11730 2149 11731 2151 11733 2153 k b 1669B
-Od:
OntB
-91l
-- vl!
' ll N O FLIT N O N O I1607 )
HV HV HV j 11612 11613 18' 11607
, TD TOVER TO BASIN M.AMML GMM
/~\\
/~\\
/\\
TRAIN *B*
2-1202-P4-002 2-1202-P4-006 2-1202-P4-004 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-002 COOLING VATER PUMP CDOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
VATER TOVER
=,
,r c,r.
unwere.
n iu
-m e
-2
.m.
m.s mismas vi risw. r= est 1
.-26-gp sits eL 3 LF3nft 10 KV 19 (F 2W.9H3H JK r
e-e -=
ma'


O                                                                                                                                                        O                                                                                                                  O NOTE THIS IA A SIMPLIFIED DIAGRAM                                                                                                                                            CV USED TO DEPICT A TEST CIRCUIT.
=== ia aca"3 Southern Company Services. Inc.FOR Southern Nuclear Operoling Company i
N                        9446                              M[><]H/' ACID ADDITION REFER TO P&lD FOR DETAILS.                                                                                                                                                                          (155)    (040) N                                                          BLIND FLANGE h                                  142                                        FC              OVDOVN
VOGTLE ELECTRIC GENERATING PLANT K58"'
                                                                                                                                                                                                                            /    I X
saawa
7                      )
=c "N"
ylSPERSANT ADDITION s                                                  !
vs UNIT 2 PUMP INSERVICE TESTING LOOP FOR
3'                      '048)              yy y a4-                                                                                                                                                                              4' h
",imma "E C''
18'                                      S QMCB                                                                                          g DMCB                                                g DMCB                                                                                      [6' 1602A                                                                                                            1608A                                                1634 18'                                                                                              18" I                                                                                          g                                                                            l                                                                                                  ,
our av.
11760                                                            l        -
NUCLEAR SERVICE COOLING VATER l
l 11761                                                                          l        11762 l                                                                                                                                                  _
PUMP 2-1202-P4-002 N/A N/A ISI-D-251 171 2
1668 NSCVS 24 . COMPONENTS PDI    PI                                          ,l                      l PDI      PI                                                                                          PDI                    PI                                                                                                  >
i
11726 2148                                                                                          11727 2150                                                                11729 2152 g                                                                                HV II          b                                                                                                    '"                                                        1668B 4;rll QKB                          -iluri!                                                ' ll                                -ilarll                                                                                          :=
N U                                            / LIT                                  N O                                                                                    N O 1606                    HV                                                                                      HV HV                                                                    1160                                                                                      1160-11600                                                                                                                                                                                                                                                                            18'
                                                                                                                                                                                                                                      , TO TGVER                                                  ,  TO BASIN N                                    Ah                                                                                                                  '    -                                          L
                                            /~\                                                                                                                /          \                                        / \                                                                                                    '
2-1202-P4-001                                                                                                      2-1202-P4-005                                            2-1202-P4-003                                                                TRAIN      'A' NUCLEAR SERVICE                                                                                                NUCLEAR SERVICE                                              NUCLEAR SERVICE                                                        2-1202-V4-001                          '
COOLING VATER PUMP                                                                                          COOLING VATER PUMP                                                COOLING VATER PUMP NUCLEAR SERVICE COOLING VATER LOVER                        i (SPARE)
        ,,        ,c      ,,  c,                                                ust.m.                                                    -i          -,      ma            -.    -s    m-s
        .        me        ass  vi      unea m                                                                                              77 s-a-se    as    ets    ursarts in arv e. y enesm32-t                                                                      77C
        *      ''"     '"            "'*** " """'                                                                                      #                                                Southern Company Services. Inc.roR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT ==*          "                                                         =*=    8"c
                                                                                                                                                                                                                                    '""                                                           " " ' v5 UNIT 2                                                                                             "
PUMP INSERVICE TESTING LOOP FOR                         " ,,an .                                      $."d              i., .t NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-001              N/A                                       N/A             ISI-D- 250          10F 1 2


O                                                                                                                                                                                                                         O                                                                               O                 !
O O
NOTE: THIS IA A SIMPLIFIED DIAGRAM                                                                                                                                                                                                                 CV USED TO DEPICT A TEST CIRCUIT.                                                                                                                                                                                                     9447                                  MC)<]l
O NOTD THIS IA A SIMPLIFIED DIAGRAM CV MD<]l lMpCID ADDITION USED TO DEPICT A TEST CIRCUIT.
                                                                                                                                                                                                                                                                                                  '                    l'/pCID ADDITION (049):
9446 REFER TO THE P8.ID FOR DETAILS.
REFER TO THE P8,ID FOR DETAILS.
O (040) (D743 BLIND FLANGE
TE g                          TO                      @F        Hl (077) lM BLIND FLANGE
@ 2* ;g; g
                                                                                                                                                                      - 1643                                                                          FC               BLOVDOVN                           g          g
TO
                                                                                                                                                                                                                                                                                                  ,      1            ,
;g TE FC BLOVDOVN
ISPERSANT ADDITION 7'                                          (168)     (079)     (078) 3*       S      (050)                  yyy                                                                  >
- 1642 g1 y g
p h                                                                                                    h                                                                                                                                          h                                                                            I6' OMCB                                                                                                                                                                          QMCB                                             QMCB                                                   3 18'                                   H 1603A                                                                                                                                                                                  1609A                                                  1635 j
nISPERSANT ADDITION (156)
18'                                                                                                                                               W              g I                                                                                                                              g                                                                                                                                                                           '
(076)
l               11763              b                                                            l                                   11764                                                                                  -
QZ5) 3' L018.)
l           11765              -
U y y 24*
u 1g                                                                                                        =    p;                                                                                                                              -=p 1669 g                                                                                                          g                                                                                                                                    g                                                                        NSCVS
24*
                                                                                                                                                                                                                                                                  ~ "
j[
                                                                                                                                                                                                                                                                ~
j[
                                                                                                                  ~~"
j 18 QMCB QMCB QMCB 16*
                                              ,,                                                                                                                                                                                        n                                                    y,                  ,      ,          24 . COMPONENTS PDI       PI                                                                                                                                 PDI                                 PI                                                               PDI   PI                         .l 11730 2149                                                                                                                                11731                              2151                                                                  11733 2153 k              b                                                                                                                                                                             1669B
1602A 1608A 1634 18' 18' g
                -Od:                   ' ::                                OntB                                      -91l                                                                                      ' ::                                            -- vl!              ' ll                                      :
j 11761 l
N  O                                                FLIT                                                        NO                                                                                                                              NO                                                                                  '
!!762 l
I1607 )                                    HV                                                                                                                                     HV HV                                                               j 11612                                                                                                                                                        11613 11607                                                                                                                                                                                                                                                                                                            18'
11760 l
                                                                                                                                                                                                                                                                                                              , TD TOVER               TO BASIN M.AMML                                                                                                                                                                                                                                                                            GMM                                                        ,
1 1r Ig 1668 NSCVS
                                          /~\                                                                                                                                                                               /~\                                                           /\
~~"
2-1202-P4-002                                                                                                                                                        2-1202-P4-006                                                              2-1202-P4-004                          TRAIN *B*                     '
O 24 COMPONENTS
NUCLEAR SERVICE                                                                                                                                                   NUCLEAR SERVICE                                                                   NUCLEAR SERVICE                     2-1202-V4-002 COOLING VATER PUMP                                                                                                                                         CDOLING VATER PUMP                                                                       COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                                       VATER TOVER
,l PDI PI PDI PI PDI PI
  =,               ,r      ,    c,r.                                                             unwere.                                                                                    n iu                  -m e                   -2      .m. m.s      mismas
{
    ,            ,-,-          vi      risw. r= est                                                                                                                                        "
i 11726 214 8 11727 2150 11729 2152 g
1             .-26-gp  sits  eL 3    LF3nft 10 KV 19 (F 2W.9H3H                                                                                                                          JK r            e-e -=  ma'            === ia aca"3                                                                                                                                    #
b 1668B g
Southern Company Services. Inc.FOR Southern Nuclear Operoling Company                     i
:gg:
                                                                                                                                                                                                                                                                                                                  "                  saawa  =c VOGTLE ELECTRIC GENERATING PLANT K58"'   '**                      "N"     vs UNIT 2 PUMP INSERVICE TESTING LOOP FOR                 " ,imma            "E C''          our av.
-igg:
NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-002                N/A         N/A     ISI-D- 251        171 2
-ligg:
' !l
'1606 I HV HV
( j 116)0 HV 1160
=
11600 18*
,TO TOVER TO BASIN N_AhAh&NA L
/~\\
/
\\
/ \\
2-1202-P4-001 2-1202-P4-005 2-1202-P4-003 TRAIN *A*
NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-001 COOLING VATER PUMP CDDLING VATER PUMP CDOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
VATER TOVER
=v
,c em ust.ieram i
e ar 3 m
sio.uins w.-
er.:
vs issure r, en n
s t
1-PSM Wss WL S LPD.TED TD KV as IF SI400t23-1 JK
~
Southern Company Services, Inc.FOR Southern Ptuelear Operating Company V0GTLE ELECTRIC GENERATING PLANT K5= * "
'aava
'=c UNIT 2 "t'
mu' vs 5."$ C" m,
I
' ~
PUMP INSERVICE TESTING LOOP FOR ua
,cy.
NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-003 N/A N/A ISI-D-252 10F 1 2


O                                                                                                             O                                                                                                                                                                                                           O NOTD THIS IA A SIMPLIFIED DIAGRAM                                                                                                                 CV USED TO DEPICT A TEST CIRCUIT.
O O
REFER TO THE P8.ID FOR DETAILS.                                                             O                                9446                                                                                                                              MD<]l
O L
                                                                                                                                                                                                                                                                                          '                                  lMpCID ADDITION (040) (D743                                BLIND FLANGE TE g                                                         TO                                                                                    @ 2* ;g; ;g FC                                                BLOVDOVN
NOTD THIS IA A SIMPLIFIED DIAGRAM CV i
                                                                                                      - 1642 g1 y                                  g      nISPERSANT ADDITION
/ 1*lNr li/pCID ADDITION i
                                                                                                                                          >'                                                                                                                                    (156)                     (076)            QZ5) 3' L018.)                               Uyy 24*                                        j[                                                                                                                                                                                                          24*
USED TO DEPICT A TEST CIRCUIT.
j[                                                                                                                                                           j QMCB                                                              QMCB                                                                                                                                                          QMCB                                                      16*
9447 i
18 1602A                                                                  1608A                                                                                                                            1634 18'                                                                  18' g                                                                   ;                                                                                                                                                                                                                                                  ,
REFER TO THE P&ID FOR DETAILS.
11760                                                          . j 11761                                                                                      !!762 l                                                                       l                                                                     l 1                                                                      1r                                                                                Ig 1668
(049F (677)
                                                                                                                                                                            ~~"
BLIND FLANGE D
NSCVS O                                                        ,l
TO FlNl lig TE FC BLDVDOVN g
                                                                                                                                                                                                                                                                                                                                ,          24 COMPONENTS g
- 1643 I
PDI 11726 214 8 PI                                                           PDI 11727 2150 PI                                                                             PDI 11729 2152 PI
f X
{            i b                 '"                                                                                                                                                                                                        1668B
ylSPERSANT ADDITION s
                    -ligg:                ' !l                          g                      :gg:
i
HV
>{
                                                                                                                                                                                      -igg:                              ' ::
Q6_8)
HV                                             '1606 I HV 11600                                            ( j 116)0                                                            1160                                                                                                                                                                                      =
(079)
18*
(6T8) 8 3'
                                                                                                                                                                                                                                                                                                              ,TO TOVER                               TO BASIN N_AhAh&NA                                                                                                                                                                                                                                        L
(050)
                                              /~\                                                                     / \                                                                                                                   / \
]fy 1f 24' 24' g
2-1202-P4-001                                                            2-1202-P4-005                                                                              2-1202-P4-003                                                                                                        TRAIN *A*
g j
NUCLEAR SERVICE                                                           NUCLEAR SERVICE                                                                           NUCLEAR SERVICE                                                                                                         2-1202-V4-001 COOLING VATER PUMP                                                       CDDLING VATER PUMP                                                                         CDOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                                                                                                                                                    VATER TOVER
OMCB QMCB l6'
        =v           ,c      ,,  em                                                ust.ieram                  i      e  ar 3          . m                                  sio.uins
[
        .          w.-      er.:  vs        issure r, en                                                    n                                                                                                                                                                                                                                                                           s t          1-PSM    Wss  WL S    LPD.TED TD KV as IF SI400t23-1                                  JK
OMCB 3
        '          ~        "              " ' " * " ' ' * " '
H 18 1603A 1609A 1635 18" 18' g
Southern Company Services, Inc.FOR Southern Ptuelear Operating Company K5= * "                           'aava        '=c V0GTLE ELECTRIC GENERATING PLANT UNIT 2                                                                                                 "t'                        mu'                vs
g j 11765
                                                                                                                                                                                                                                                                                                                ' ~
[
PUMP INSERVICE TESTING LOOP FOR                                                                                                                     ua      5."$ C"                          m,        ,cy.
l 11763 l.j 11764 l
I NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-003                                                                                            N/A               N/A   ISI-D- 252                    10F 1 2
m o
V 1669 NSCVS a
[
~~*
v 24 COMPONENTS n
M"
~~ "
PDI PI PDI PI PDI PI d
11730 214 9 11731 2151 11733 2153 g
g b
1669B
-il>rll
' ll OtiCB
-H>rll
' ll
--{>rll NO
[ LIT NO N O I1607I HV HV HV (j 11612 11613
=:
11607 18' l
. TO TOVER TO BASIN MJM A-GMM
/~\\
/~\\
/~\\
2-1202-P4-002 2-1202-P4-006 2-1202-P4-004 TRAIN *B' NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-002 COOLING VATER PUMP CDOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARD VATER TOVER
=v.
 
==
s, o,
usawin.
meu me n.u nm. 6 -s suomrs
*w ass vi issues rar m n
i i-a-se ses at e emn in arv i, or emum a
Southern Company Services, Inc.FOR Southern Nuclear Operating Company
[
VDGTLE ELECTRIC GENERATING PLANT ' " * * "
 
==
'"e
""' v5 UNIT 2 C"
u PUMP INSERVICE TESTING LOOP FOR muta
.y.
NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-004 N/A N/A ISI-D-253 1 [F 1 2 f
 
O O
O NOTE: THIS IA A SIMPLIFIED DIAGRAM CV 4M[><]' g"MCID ADDITION USED TD DEPICT A TEST CIRCUIT.
9446 REFER TO THE PLID FOR DETAILS.
(047}
D TO 2' ;g;
;,g TE h
1642 FC BLOVDOVN I
'/
X
'/
nISPEP.SANT ADDITION (156 )
(UT67 (075)
>S 3'
(048) y Jf1[
O 24' g
[
g 24' 18' S
4 QMCB OMCB
[6' QMCB 1602A 1608A 1634 18' W
3 g
l 11760 l
11761 l
j 11762 1
L la v
g 668 NSCVS C
24 COMPONENTS t
PDI PI PDI PI PDI PI il 11726 2148 11727 2150 11729 2152 b
g y
1668
-1XC
' ll OMEB Hl>r"
' ll
---G>r" NO
[L1T NO NO
:h 11606} HV HV HV (f 1160 1160
=-
11600 18
,TO TOVER
, TO BASIN MJMMAA-G
/\\
/\\
/\\
2-1202-P4-001 2-1202-P4-005 2-1202-P4-003 TRAIN
'A' NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-001 CDDLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
VATER TOVER av mrs
=
ci.,
u se-rum.
l.mu
 
==
-u m.
=u x rs
*s-..
ms
.a nu. = n.
n i
-n-a.
.ss
=e sans m av a or rumn-i a
*~
" ~ '
" " ~ " ~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT "5='
 
==
"c UNIT 2


O                                                                              O                                                                              O NOTD THIS IA A SIMPLIFIED DIAGRAM                                                                  CV                                                                                              i i
=== wt PUMP INSERVICE TESTING LOOP FOR
USED TO DEPICT A TEST CIRCUIT.                                                          9447                                / 1*lNr i
" [v,$ $."."
li/pCID ADDITION REFER TO THE P&ID FOR DETAILS.                                        (049F                                                                    (677)              BLIND FLANGE TE              D FC TO BLDVDOVN FlNl          g lig                                    ;
~
                                                                    - 1643                                                                      I f
m NUCLEAR SERVICE CDOLING VATER PUMP 2-1202-P4-005 N/A N/A ISI-D-254 10F ! 2
i X            ylSPERSANT ADDITION s
8 Q6_8)    (079)        (6T8) 3'  >{      (050)                  ]fy 1f 24'                    g                                                                                  24' g                                                                                                  j  '
QMCB                                          l6' 18                                      OMCB                                          3  OMCB                                      H                                                                [
1603A                                              1609A                                          1635 18"                                            18' g                                              g l          11763                                  l .j 11764                                    l    . j 11765 m                                                  o                                                      V 1669 a                                                                                                                                                                                NSCVS
      ~~- "                                                                                              ~~*
n                    M"                                                                                                                    24 COMPONENTS v                    ,
PDI      PI                                      PDI      PI                                        PDI    PI                        d 11730 214 9                                        11731    2151 g    11733 2153                                                                      ,
g                                                  b                                                                                                  1669B                                  ,
        -il>rll              ' ll            OtiCB        -H>rll              ' ll                          --{>rll                                                      ::
NO                              [ LIT            NO                                                  NO I1607I HV                                              HV HV                              (j 11612                                              11613                                                                  =:                            .
11607                                                                                                                                                              18'                        '
                                                                                                                                                    , . TO TOVER            ,  TO BASIN MJM                                                                              A-                                              GMM
                                /~\                                                /~\                                            /~\
2-1202-P4-002                                      2-1202-P4-006                                      2-1202-P4-004                          TRAIN *B'
* NUCLEAR SERVICE                                      NUCLEAR SERVICE                                  NUCLEAR SERVICE                      2-1202-V4-002 COOLING VATER PUMP                                  CDOLING VATER PUMP                                  COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARD                                                                            VATER TOVER                        ;
=v.      ==       s,  o,                            usawin.              meu  me    n.u  nm. 6 -s    suomrs
.        *w      ass  vi      issues rar m                                n                                                                                                                            !
i        i-a-se  ses  at e    emn in arv i, or emum                      a Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT '""" * * "                          ==    '"e
                                                                                                                                                                            ""' v5                      '
UNIT 2                        "
PUMP INSERVICE TESTING LOOP FOR                       muta              C"           u  .y.
NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-004            N/A           N/A   ISI-D- 253          1 [F 1 2


O                                                                                 O                                                                             O NOTE: THIS IA A SIMPLIFIED DIAGRAM                                                                       CV USED TD DEPICT A TEST CIRCUIT.                                                                                             '
O O
9446 REFER TO THE PLID FOR DETAILS.                                       (047}    '
O NOTE: THIS IA A SIMPLIFIED DIAGRAM M
4M[><]' g"MCID ADDITION TE                D                -
USED TO DEPICT A TEST CIRCUIT.
TO                            2' ;g;       ;,g h        1642                        FC               BLOVDOVN
9447 MC)<:}----{MpCID ADDITION REFER TO THE P8.ID FOR DETAILS.
                                                                                                                                                  '/
(049)
I X          '/      nISPEP.SANT ADDITION (156 )     (UT67      (075) 3'       >S      (048)                 y Jf1[
Q67_) 2' ;g;
O                                  24' g                                                                                                       g                                 24'
;gp_4[ BLIND FLANGE (041) (077)
D TO TE FC BLOVDOVN g
- 1643 1
ISPERSANT ADDITION
>S (168)
(079)
(078) 3' (050) y Q y a"
ET' 24' h
j j[
OMCB QMCB QMCB I6' 18' H
3 1603A 1609A 1635 18' W
1 g
g l
11763 l
11764 l
11765 4
le Ip 1m y
1669 NSCVS
~ ~ "
V 24. COMPONENTS 7"
PDI PI PDI PI PDI PI
,l l
i 2149 11731 2151 11733 2153 n @ 11730 b
h 1669B
-{;rll
' ll OtiCB
---g;rll
' ll
--l;rll
' ll NO (LIT N O N O 1:
l HV HV l1607 ) 11612 HV
()
11613
=
11607 Ig-
, TO TGVER TO BASIN MAMMA.
G
/
\\
/ \\
/\\
l 2-1202-P4-002 2-1202-P4-006 2-1202-P4-004 TRAIN *B'
[
[
QMCB OMCB                                          [6' 18'                                  S                                              4 QMCB 1602A                                              1608A                                            1634 18'          ;                                      W              g                                                            ,
NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-002 COOLING VATER PUMP CDOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)
3 l                11760                            l          11761                                      l    . j 11762 1                                                  L                                                    lag                                                          v 668 NSCVS
VATER TOVER t
_-.                              , ,                  "                            t    #
uv.
C                    ,
satt se ces scscorruse meu was me.2 maa mes sciemus me
il
                                                                                                                                                                          ,            24 COMPONENTS PDI      PI                                      PDI        PI                                          PDI    PI 11726 2148                                      11727 2150                                      g    11729 2152                                  y b                                                                    '"                            1668
          -1XC                    ' ll        OMEB          Hl>r"                  ' ll                          ---G>r" NO NO                        [L1T                NO                                                                                                            :h 11606} HV                                                    HV HV 11600                            (f 1160                                                      1160                                                                  =-
18
                                                                                                                                                              ,TO TOVER            , TO BASIN MJMMAA-                                                                                                                              G
                                      /\                                                  /\                                              /\
2-1202-P4-001                                      2-1202-P4-005                                      2-1202-P4-003                          TRAIN      'A' NUCLEAR SERVICE                                     NUCLEAR SERVICE                                     NUCLEAR SERVICE                     2-1202-V4-001 CDDLING VATER PUMP                                 COOLING VATER PUMP                                   COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                         VATER TOVER av      mrs            =  ci.,                    u se-rum.              l .mu    ==      -u    m.    =u      x rs
  ,      *s-..        ms  .a      nu. = n.                                    n i        -n-a.       .ss  =e    sans m av a or rumn-i                        a
  *~      " ~ '        "          " " ~ " ~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT "5='            "                  ==    "c UNIT 2                  ""'                    === wt
                                                                                                                                                                  ~
PUMP INSERVICE TESTING LOOP FOR                        m        " [v,$ $."."            , .
NUCLEAR SERVICE CDOLING VATER PUMP 2-1202-P4-005              N/A        N/A      ISI-D- 254            10F ! 2


O                                                                                          O                                                                                          O NOTE: THIS IA A SIMPLIFIED DIAGRAM                                                                        M USED TO DEPICT A TEST CIRCUIT.                                                                    9447                                  MC)<:}----{MpCID ADDITION REFER TO THE P8.ID FOR DETAILS.                                              (049)    -
==
(041) (077)
vs issa. ra.,s, n
TE                  D                        TO                      Q67_) 2' ;g;          ;gp_4[ BLIND FLANGE
I FES M 88:
                                                                            - 1643                          FC                BLOVDOVN 1
WL 5 LF9htE TB KV 19 IF russes33-2 JJc t
g            ,
Southern Company Services, Inc.FOR Southern Nuclear Operating Company f
ISPERSANT ADDITION (168)    (079)      (078) 3'    >S      (050)                  yQy a
~
ET'                        j                                                        j[                                24' h                                                      ,
~
I6' 18'                              H      OMCB                                                      QMCB                                        3  QMCB 1603A                                                      1609A                                              1635 18'            g W              g                                                                      ,
"~""
1 l          11763                                    l          11764                                      l            11765                                                                                              4 1m                                                                                                          !
V0GTLE ELECTRIC GENERATING PLANT''"
le                                                    Ip y                                                                                                                1669 NSCVS
= = ' vs i
                                                                                                                      ~
"s= ' "
                                                                                                                        ~ "
**=
7"                                                      !"                                                                                                                                24 . COMPONENTS V                    ,l PDI        PI                                            PDI        PI                                            PDI    PI                          i      l 2149                                          11731      2151                                          11733 2153                                                                                    !
''c UNIT 2 PUMP INSERVICE TESTING LOOP FOR
n @ 11730                                                    b                                                  h      @
",muis
1669B
$$C" m,
          -{;rll              ' ll                OtiCB        ---g;rll                ' ll                            --l;rll              ' ll 1:
f
NO                                (LIT                NO                                                      NO l                                                              HV                                                HV HV 11607                              ()
.y.
l1607 ) 11612                                                  11613                                                                    =
NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-006 N/A N/A ISI-D-255 1 [F 1 2
Ig-                                  ,
+
                                                                                                                                                                  , , TO TGVER            ,            TO BASIN MAMMA.                                                                                                                                      G
1
                                  / \                                                        / \                                                  /\                                                                              l 2-1202-P4-002                                              2-1202-P4-006                                        2-1202-P4-004                            TRAIN *B'                                    [
NUCLEAR SERVICE                                            NUCLEAR SERVICE                                        NUCLEAR SERVICE                        2-1202-V4-002                                    !
COOLING VATER PUMP                                        CDOLING VATER PUMP                                      COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE)                                                                                VATER TOVER t
uv. satt    se  ces                            scscorruse                meu    was    me.2    maa  mes    sciemus
  .      me      ==    vs       issa. ra. ,s,                                     n JJc                                                                                                                                            t I       FES M   88:   WL 5     LF9htE TB KV 19 IF russes33-2
  *      ~      ~              "~""
Southern Company Services, Inc.FOR Southern Nuclear Operating Company "s= ' "                               **=  ''c V0GTLE ELECTRIC UNITGENERATING 2              PLANT''"                     = = ' vs                               i PUMP INSERVICE TESTING LOOP FOR                 " ,muis           $$C"                       m,     .y. f NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-006                 N/A           N/A     ISI-D- 255                 1 [F 1 2     !
                                                                                                                                                                                                                                  +
1                                               .                                            -                                                                                .          _ - _ - _ _ _        _        _ _ _ _


NOTE: THIS IS A SIMPLIFIED ' DIAGRAM USED TO DEPICT A TEST CIRCUIT.                                                           ,
NOTE: THIS IS A SIMPLIFIED ' DIAGRAM USED TO DEPICT A TEST CIRCUIT.
REFER TO THE PLID FOR DETAILS                                                           <
REFER TO THE PLID FOR DETAILS HV FI PI 1670 2156 8895 i
HV                                         FI PI                                                                                                                                                   1670                                         2156 8895 i
O l
ag            O                             .      l                                                 lll                                                                                                   ?
lll
8'X6'                             LD 4 0MCB                                                     FI                                   HV                                             M PI                                                       2166                                                     2157                                                                                 167A 1671                                                                                                                                                                            i 2154                                                                                                                                                                                                                                                                                                           ,
?
                                                                  ,                                                                              LD               8'X6'                                       ,
ag 8'X6' LD 4 0MCB M
FI HV PI 2166 2157 1671 167A i
2154 LD 8'X6' 3
[-
[-
3 Ml!                       l l               C
6' Ml!
[                                                                                                                             I 6'
l l C
PI
[
                                                                ~
I PI PDI
PDI                                    >    4 6'           2155                                                                         ,,
~
11728 QMCB 1606                                                                           PI 8894                             OMCB                                                                                                                                                                       i I                                 lp                                                                                                                               i PD1                   1607 d!                       D                                               1173 WMAhA.AA.A> h                                                                                                             vhJh                                                                                                                                       N
6' 2155 4
                                                            /       \                                                                                                                                     / \                                                                                                 3r                           ,
QMCB 11728 PI 1606 8894 OMCB i
2-1202-P4-007                                                 TRAIN 'A'                                                                         2-1202-P4-008                                                                                         TRAIN 'B' TRANSFER PUMP                                             2-1202-V4-001                                                                     TRANSFER PUMP                                                                                       2-1202-V4-002                         '
I lp i
NUCLEAR SERVICE COOLING                                                                                                                                   NUCLEAR SERVICE C00 LING VATER TOVER                                                                                                                                                                             VATER TOVER                         ,
PD1 1607 d!
=v. mm                   .,            o-,                             ==.-r                               .-.    .-,  .-2             m.  -.        __.
D 1173 WMAhA.AA.A> h vhJh N
e   ++=               mm               vs     namn rm m -                                                 n i   i-=-es           ===               ==       warte ve av. m n.nem         av. i, n_._3a                 a
/
* Ate-M             vtV               M       333 Pg-ge,. & 7                                                                                                                                                                                                                                                                           ,
\\
Aac w+w                             av.S         mm
/
                                                            -,7         EELETT9 serv esmeras gw.s                                         Southern Company Services, Inc.rog Southern Nuclear Operating Company                                                                                                             [
\\
V0GTLE ELECTRIC GENERATING PLANT =$*<*                                                                         "                                      =   =c UNIT 2                                             ~ '**
3r 2-1202-P4-007 TRAIN
PUMP INSERVICE INSPECTION LOOP                                                                                                 -.                    " E *,'. " '    rv =v.       ,
'A' 2-1202-P4-008 TRAIN
FOR TRANSFER PUMP                                                                                                                                                       ;
'B' TRANSFER PUMP 2-1202-V4-001 TRANSFER PUMP 2-1202-V4-002 NUCLEAR SERVICE COOLING NUCLEAR SERVICE C00 LING VATER TOVER VATER TOVER
2-1202-P4-007                                                     N/A                                                   N/A           ISI-D- 256   1 IF 1 3
=v.
mm o-,
 
==.-r
.-2 m.
e
++=
mm vs namn rm m -
n i
i-=-es
 
===
==
warte ve av. m n.nem av. i, n_._3a a
Ate-M vtV M
333 Pg-ge,. & 7 Aac w+w av.S mm
-,7 EELETT9 serv esmeras
[
gw.s Southern Company Services, Inc.rog Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT =$*<*
=
=c
" E *,'. " '
rv UNIT 2
~ '**
PUMP INSERVICE INSPECTION LOOP
=v.
FOR TRANSFER PUMP 2-1202-P4-007 N/A N/A ISI-D-256 1 IF 1 3


(
(
v                                                                                       J                                                                      s NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT.
J v
REFER TO THE P&ID FOR DETAILS HV                 FI pg                                                                                                         1670               2156 8895
s NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT.
: e.                 I     i
REFER TO THE P&ID FOR DETAILS HV FI pg 1670 2156 8895 e.
                                                                      ^       8'X6' i' g 't                            k
I i
                                                                                                      'LO' 4 0MCB                                                                                                 4 0MCB PI                               166A 2157                   1671                         167A                           ,
i g 't k
2154 LO             8'X6' ll!         l l           0 8'
^
PI PDI                     -- ;                                        6*         2155                                             -
8'X6'
11728 QMCB 1606                                                                   PI 8894                     OMCB lH 1607 N                         E                               hDI 1173 WMA                                                             N                                   vm.)                                             N
'LO' 4 0MCB 4 0MCB PI 166A 2157 1671 167A 2154 LO 8'X6' ll!
                                  /     \                                                                                             / N 2-1202-P4-007                                           TRAIN 'A'
l l 0
                                                                                                                                                                          +
8' PI PDI 6*
2-1202-P4-008                     TRAIN *B' TRANSFER PUMP                                       2-1202-V4-001                                     TRANSFER PUMP                   2-1202-V4-002 NUCLEAR SERVICE CDOLING                                                               NUCLEAR SERVICE CDOLING VATER TOVER                                                                       VATER TOVER ev. ==       =     o.,                     =====                           .-,      .-,  .-,    -.  -s         _ ..
2155 QMCB 11728 PI 1606 8894 OMCB lH hDI 1607 N
.    =+     som     vs unes run ni                                         n i   N-88   "BS     E3 LP=YE3 70 =V. EB EE.MB33-9 . IEv. 39 tu4pge3M       J.c e   4-w   ww       =   => = : . == arw             ev ---               a a   ie-e-w sv. aats . wn . .c   ,2                                   ages                               Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT =       5= * "           n=wa   *=c PUMP INSERVICE INS ECTION LOOP FOR TRANSFER PUMP re =v.
E 1173 WMA N
2-1202-P4-008                 N/A     N/A   ISI-D- 257     1 [F 1 3 !
vm.)
N
/
\\
/
N
+
2-1202-P4-007 TRAIN
'A' 2-1202-P4-008 TRAIN *B' TRANSFER PUMP 2-1202-V4-001 TRANSFER PUMP 2-1202-V4-002 NUCLEAR SERVICE CDOLING NUCLEAR SERVICE CDOLING VATER TOVER VATER TOVER ev.
 
==
=
o.,
 
=====
-s
=+
som vs unes run ni n
i N-88 "BS E3 LP=YE3 70 =V. EB EE.MB33-9. IEv. 39 tu4pge3M J.c e
4-w ww
=
=> = :.== arw ev ---
a a
ie-e-w sv.
aats
. wn..c
,2 ages Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT = 5= * "
n=wa
*=c PUMP INSERVICE INS ECTION LOOP re
=v.
FOR TRANSFER PUMP 2-1202-P4-008 N/A N/A ISI-D-257 1 [F 1 3


CCW Pumps (2-1203-P4-001, 002, 003, 004, 005, & 006)
CCW Pumps (2-1203-P4-001, 002, 003, 004, 005, & 006)
L             System Function
L System Function
'                                                  Remove waste heat from the spent fuel pool heat
~
                                              ~
Remove waste heat from the spent fuel pool heat exchangers, RHR heat exchangers and the RHR pump seal coolers during plant operation, plant cooldown and during a s
exchangers, RHR heat exchangers and the RHR pump seal s
postulated post-accident condition. This heat energy is then transferred by the component cooling water heat exchangers to the NSCWS. The CCWS functions as an 4
coolers during plant operation, plant cooldown and during a
intermediate system between a radioactive fluid system and the non-radioactive NSCWS, which operates at a higher system pressure This arrangement greatly reduces the probability of radioactive fluid leakage to the enviroment by means of the NSCWS.
'                                                  postulated post-accident condition. This heat energy is then transferred by the component cooling water heat 4
Quantity 6
exchangers to the NSCWS. The CCWS functions as an intermediate system between a radioactive fluid system and
4 1
'                                                  the non-radioactive NSCWS, which operates at a higher system pressure               This arrangement greatly reduces the     :
Type Horizontal, centrifugal, single-stage, split volute with mechanical seals Manufacturer /Model Ingersoll-Rand /10x18 SE Rated Capacity 5000 gpm (each)
probability of radioactive fluid leakage to the enviroment by means of the NSCWS.
Rated Total Dynamic Head 160 feet O
;          Quantity                               6 4
Driver Type Electric Motor, Westinghouse, LAC-LLD, 5008-S Horsepower 300 Speed 1761 rpm-Power Supply 4160V,60 Hz,3 phase Code Class 3
1 Type Horizontal, centrifugal, single-stage, split volute with mechanical seals Manufacturer /Model                   Ingersoll-Rand /10x18 SE Rated Capacity                       5000 gpm (each)
Project Class 313 Outline Drawing 2X4AF01-109 & 2X4AF01-110 Instruction Book 2X4AF01-137 Physical Location Aux Bldg, Level A, Rooms R-A96 & R-A98 P&ID 2X4DB136 Surveillance Procedure 14803-2 Pump Test Loop Diagrams ISI-D-258 through ISI-D-263 Test Parameter Sheets Page 16-3 through 16-8 16 - 1 Rev.O
Rated Total Dynamic Head O       Driver 160 feet Type Electric Motor, Westinghouse, LAC-LLD, 5008-S Horsepower               300 Speed                     1761 rpm-Power Supply             4160V,60 Hz,3 phase Code Class                             3 Project Class                         313 Outline Drawing 2X4AF01-109 & 2X4AF01-110 Instruction Book                     2X4AF01-137 Physical Location                     Aux Bldg, Level A, Rooms R-A96 & R-A98 P&ID                                   2X4DB136 Surveillance Procedure                 14803-2 Pump Test Loop Diagrams               ISI-D-258 through ISI-D-263 Test Parameter Sheets                 Page 16-3 through 16-8 16 - 1                             ,            Rev.O


O                                                                                         O                                                                                                                                                                                           O i
O O
Test Parameter Table - Pump 2-1203-P4-001 (Figure ISI-D-258)                                                                                                                                                                                               ;
O i
Instrumentation Utilized                     Ref.           Acceptable                                               Alert                                     Action                                                                                         l Parameter           Iest Frea.               1.D. NoJ3)         Range       Rea. Acc.           Value           Range                                                   Range                                     Range                       Comments
Test Parameter Table - Pump 2-1203-P4-001 (Figure ISI-D-258)
                                                                                                                                                                                                                                                                                                                                        .l Speed (N)                 NA                       NA                 NA         NA                 NA             NA                                                     NA                                         NA                         Constant speed driver L
Instrumentation Utilized Ref.
Inlet Pressure           Qtr                     PI-1878             0-60       12%                 NA             NA                                                       NA                                         NA                         NA (Pi)                                                             psig Outlet
Acceptable Alert Action l
* Pressure             Qtr                     PI-1858             0-200       12%                 NA           NA                                                       NA                                           NA                         NA                                                 .
.l Parameter Iest Frea.
(Po)                                                             psig                                                                                                                                                                                                                                             ,
1.D. NoJ3)
Differ.
Range Rea. Acc.
Pressure             Qtr                     NA(1)               NA         12%                 APr           .90 - 1.10APr                                           NA                                           <.90 er >l.10APr NA                                                                           ,.
Value Range Range Range Comments Speed (N)
(AP)
NA NA NA NA NA NA NA NA Constant speed driver L
Flowrate             Qtr                     FI-I1794           0-10000     12%                 Qr           NA                                                     NA                                           NA                         Flowrate is set at reference value (Q)                                                               gpm                                                                                                                                                                                                                                               !
Inlet Pressure Qtr PI-1878 0-60 12%
Vib.
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1858 0-200 12%
Amp.                 Qtr                     (2)                 NA         .1 5 %               Vr           s 2.5Vr                                                 > 2.5Vr - 6Vr                                 >6Vr or                     NA (V)(4)                                                                                                                                                                 or >.325 in/s                                 >.70 in/s Nctes:
NA NA NA NA NA (Po) psig Differ.
: 1. DifTerential pressure is calculated as, AP = Po - Pi                                                                                                                                                                                                                                                           ;
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er >l.10APr NA (AP)
Flowrate Qtr FI-I1794 0-10000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA
.1 5 %
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Nctes:
: 1. DifTerential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                                                                                                   I
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
I
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
16-2                                                                                                                                           Rev.0                                                             f i
16-2 Rev.0 f
i


O                                                                                                                                                                                       O                                                                                                                                 O                 .
O O
1 Test Parameter Table - Pump 2-1203-P4-002 (Figure ISI-D-259)
O 1
Instrumentation Utilized                                                                   Ref.                 Acceptable   Alert               Action                                                                                                             ,
Test Parameter Table - Pump 2-1203-P4-002 (Figure ISI-D-259)
Oarameter                 Int Freq.                                                   ' I.D. No.(3)   Range                                       Rea. Acc.                             Value                 Range         Range               Range                                                                         Comments                             ;
Instrumentation Utilized Ref.
Speed (N)                       NA                                                             NA           NA                                         NA                                     NA                   NA           NA                 NA                                                                           Coastant speed driver inlet                                                                                                                                                                                                                                                                                                                                                                 6 Pressure                   Qtr                                                             PI-1881       0-60                                       12%                                   NA                   NA           NA                 NA                                                                           NA                                   i (Pi)                                                                                                     psig                                                                                                                                                                                                                                                         ,
Acceptable Alert Action Oarameter Int Freq.
l Outlet Pressure                   Qtr                                                             PI-1859       0-200                                       12%                                   NA                   NA           NA                 NA                                                                           NA                 i (Po)                                                                                                     psig Differ.                                                                                                                                                                                                                                                                                                                                                               '
' I.D. No.(3)
Pressure                   Qtr                                                             NA(1)         NA                                         12%                                   APr                   .90 - 1.10APr NA                 <.90 or >l.10APr NA (AP)
Range Rea. Acc.
Flowrate                   Qtr                                                             FI-l1795     0-10000                                     12%                                   Qr                     NA           NA                 NA                                                                             Flowrate is set at reference value (Q)                                                                                                     gpm I
Value Range Range Range Comments Speed (N)
NA NA NA NA NA NA NA NA Coastant speed driver inlet 6
Pressure Qtr PI-1881 0-60 12%
NA NA NA NA NA i
(Pi) psig l
Outlet Pressure Qtr PI-1859 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr FI-l1795 0-10000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm I
Vib.
Vib.
Amp.                       Qtr                                                             (2)           NA                                         i5%                                   Vr                     s 2.5Vr       > 2.5Vr - 6Vr     >6Vr or                                                                       NA (V)(4)                                                                                                                                                                                                                         or >.325 in/s     >.70 in/s t
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s t
Notes:
Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                                                                                                                                                           ;
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
direction on each accessible thrust bearing housing.                                                                                                                                                                                                                                                                                                               ,
[
[
16 -3                                                                                                                             Rev.0
16 -3 Rev.0
_ _ _ _        __.____-__m__m___-.              _ . _ _ _ . _ . . _ _ _ . - _ _ . _ . _ - _ _ _ _ _                    _ _ _ _ _ _ _ . . _ _ . _ _ _ _ _ _ _                                                      ____-_m                --                                                        - - - - -                          +         -                w--
)
m m
- m
+
w--


r                                                                                           r                                                                                                                                                                                                             -
r r
l
('
('                                                                                                                                                                                                                                                                                                     J Test Parameter Table - Pump 2-1203-P4-003 (Figure ISI-D-260)
l J
Instrumentation Utilized             Ref.                       Acceptable                                           Alert                                                                                   Action Earamtitt           Test Freq.       I.D. NoJ3)         Range     Rea. Acc. Value                       Range                                               Range                                                                                   Range           Comments Speed (N)                 NA               NA                 NA       NA           NA                           NA                                                   NA                                                                                       NA               Constant speed driver inlet Pressure           Qtr             PI-1879           0-60     12%         NA                           NA                                                   NA                                                                                       NA-             NA (Pi)                                                   psig Outlet Pressure           Qtr             PI-1860           0-200   12%           NA                           NA                                                 NA                                                                                       NA               NA                                     e (Po)                                                   psig Differ.
Test Parameter Table - Pump 2-1203-P4-003 (Figure ISI-D-260)
Pressure           Qtr             NA(1)             NA       i2%         APr                           .90 - 1.10APr                                       NA                                                                                       <.90 or >l.10APr NA (AP)
Instrumentation Utilized Ref.
Flowrate           Qtr             FI-I1796           0-10000 12%         Qr                           NA                                                 NA                                                                                       NA               Flowrate is set at reference value (Q)                                                     gpm                                                                                                                                                                                                                                                                       !
Acceptable Alert Action Earamtitt Test Freq.
I Vib.
I.D. NoJ3)
Amp.               Qtr             (2)               NA       15%         Vr                           5 2.5Vr                                             >2.5Vr - 6Vr                                                                             >6Vr or         NA (V)(4)                                                                                                                                                         or >.325 in/s                                                                             >.70 in/s 1
Range Rea. Acc.
I N:tes:                                                                                                                                                                                                                                                                                                                             ,
Value Range Range Range Comments 1
Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-1879 0-60 12%
NA NA NA NA-NA (Pi) psig Outlet Pressure Qtr PI-1860 0-200 12%
NA NA NA NA NA e
(Po) psig 1
Differ.
Pressure Qtr NA(1)
NA i2%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr FI-I1796 0-10000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm I
Vib.
Amp.
Qtr (2)
NA 15%
Vr 5 2.5Vr
>2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s 1
I N:tes:
: l. Differential pressure is calculated as, AP = Po - Pi
: l. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                                    .
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                                                                                                                       l direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial l
direction on each accessible thrust bearing housing.
L k
L k
16-4                                                                                                                                                                                     Rev.0 i
16-4 Rev.0 i
_ . . . _ _ _ . , _ _ .      ._______.___.__...._..________._________._____________._m_____._s___                                                                                              _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
. m
. s


N                 !
N Test ParameterTable - Pump 2-1203-P4-004 (Figure ISI-D-261)
Test ParameterTable - Pump 2-1203-P4-004 (Figure ISI-D-261)
Instrumentation Utilized Ref.
Instrumentation Utilized                             Ref.         Acceptable                           Alert                 Action Parameter         Test Freq.       1.D. No.f3)   Range         Beg Act Yalac                             Range                               Range                 Range                 Comments Speed (N)               NA               NA             NA             NA                           NA           NA                                   NA                     NA                   Constant speed driver Inlet Pressure           Qtr             PI-1882       0-60           12%                         NA           NA                                   NA                     NA                   NA (Pi)                                               psig Outlet Pressure           Qtr             PI-1861       0-200         12%                         NA             NA                                   NA                     NA                   NA (Po)                                               psig Differ.                                                                                                                                                                                                                             l Pressure           Qtr             NA(1)         NA           12%                         APr           .90 - 1.10APr                       NA                     <.90 er >1.10aPr NA                                         ,
Acceptable Alert Action Parameter Test Freq.
(AP)
1.D. No.f3)
Flowrate           Qtr             F1-11797       0-10000       12%                         Qr             NA                                   NA                     NA                   Flowrate is set at reference value     !
Range Beg Act Yalac Range Range Range Comments Speed (N)
(Q)                                               gpm Vib.
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-1882 0-60 12%
Amp.               Qtr             (2)           NA           i5%                         Vr             5 2.5Vr                             > 2.5Vr - 6Vr         >6Vr or             NA (V)(4)                                                                                                                                           or >.325 in/s         >.70 in/s Notes:                                                                                                                                                                                                                               .
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1861 0-200 12%
NA NA NA NA NA (Po) psig Differ.
l Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er >1.10aPr NA (AP)
Flowrate Qtr F1-11797 0-10000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr 5 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                                     '
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
r 16 - 5                                                                                       Rev.0                                 L
r 16 - 5 Rev.0 L
                                                                        .._._________________.m___          _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _        _m___.  - ___            . . -
.m m
* O                                                                         /~}
 
U                                                                       .%)
O
/~}
U
.%)
i Test Parameter Table - Pump 2-1203-P4-005 (Figure ISI-D-262)
i Test Parameter Table - Pump 2-1203-P4-005 (Figure ISI-D-262)
Instrumentation Utilized       Ref.     Acceptable     Alert           Action Parameter                     Test Frea.       I.D. No (3)   Range         Req. Acc. Yalue     Range           Bange           Range             Comments Speed                                                                                                                                                                                                 [
Instrumentation Utilized Ref.
(N)                           NA             NA             NA           NA       NA       NA             NA             NA               Constant speed driver                               :
Acceptable Alert Action Parameter Test Frea.
I.D. No (3)
Range Req. Acc.
Yalue Range Bange Range Comments Speed
[
(N)
NA NA NA NA NA NA NA NA Constant speed driver
[
Inlet Pressure Qtr PI-1880 0-60 2%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1862 0-200 12%
NA NA NA NA NA e
(Po) psig DitTer.
i Pressure Qtr NA(1)
NA i2%
APr
.90 - 1.10APr NA
<.90 er >l.10APr NA (AP) l Flowrate Qtr FI-l 1798 0-10000 i2%
Qr NA NA NA Flowrate is set at reference value i
(Q) gpm j
L Vib.
[
[
Inlet Pressure                      Qtr            PI-1880        0-60          2%      NA        NA              NA              NA                NA (Pi)                                                          psig                                                                                                                                    !
Amp.
Outlet Pressure                      Qtr              PI-1862        0-200        12%        NA        NA              NA              NA              NA                      e (Po)                                                          psig DitTer.                                                                                                                                                                                               i Pressure                      Qtr              NA(1)          NA          i2%        APr      .90 - 1.10APr  NA              <.90 er >l.10APr NA                                                  ;
Qtr (2)
(AP) l NA              NA              NA              Flowrate is set at reference value                  i Flowrate                      Qtr             FI-l 1798      0-10000      i2%        Qr gpm                                                                                                                                    j (Q)
NA i5%
L Vib.                                                                                                                                                                                                  [
Vr s 2.5Vr
Amp.                        Qtr              (2)            NA           i5%       Vr       s 2.5Vr         > 2.5Vr - 6Vr   >6Vr or         NA (V)(4)                                                                                                         or >.325 in/s   >.70 in/s Nites:
> 2.5Vr - 6Vr
: 1. Differential pressure is calculated as, AP = Po - Pi                                                                                                                                               r
>6Vr or NA L
: 2. Pcatable vibration instruments are utilized.                                                                                                                                                       l
(V)(4) or >.325 in/s
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                     !
>.70 in/s Nites:
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thmst bearing housing.
: 1. Differential pressure is calculated as, AP = Po - Pi r
: 2. Pcatable vibration instruments are utilized.
l
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial L
direction on each accessible thmst bearing housing.
i f
i f
16 - 6                                                     Rev.0                                               l i
16 - 6 Rev.0 l
i


Test Parameter Table - Pump 2-1203-P4-006 (Figure ISI-D-263)
Test Parameter Table - Pump 2-1203-P4-006 (Figure ISI-D-263)
Instrumentation Utilized                   Ref.                       Acceptable                           Alert                                               Action Parameter         Test Frea.       I.D. No.f3)     Range           Rea. Ace.         Value                     Range                               Range                                               Range                                   C.cmments Speed (N)                 NA             NA               NA             NA               NA                         NA                                   NA                                                   NA                                     Constant speed driver Inlet                                                                                                                                                                                                                                                                                               l Pressure           Qtr             PI-1883         0-60               2%           NA                         NA                                   NA                                                   NA                                     NA                                             ,
Instrumentation Utilized Ref.
(Pi)                                                 psig Outlet Pressure           Qtr             PI-1863         0-200           12%               NA                         NA                                   NA                                                   NA                                     NA                 i (Po)                                                 psig                                                                                                                                                                                                                                           ;
Acceptable Alert Action Parameter Test Frea.
Differ.                                                                                                                                                                                                                                                                                             :
I.D. No.f3)
Pressure           Qtr             NA(1)           NA             12%               APr                       .90 - 1.10APr                       NA                                                   <.90 er >l.10APr NA                                                                     l (AP)
Range Rea. Ace.
Flowrate           Qtr             FI-l 1799       0-10000         12%               Qr                         NA                                 NA                                                   NA                                       Flowrate is set at reference value (Q)                                                 gpm Vib.                                                                                                                                                                                                                                                                                               '
Value Range Range Range C.cmments Speed (N)
Amp.               Qtr             (2)             NA             15%               Vr-                       s 2.5Vr                             > 2.5Vr - 6Vr                                       >6Vr or                                 NA                                           ,
NA NA NA NA NA NA NA NA Constant speed driver Inlet l
(V)(4)                                                                                                                                               or >.325 in/s                                       >.70 in/s                                                                             1 N:tes:
Pressure Qtr PI-1883 0-60 2%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1863 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er >l.10APr NA l
(AP)
Flowrate Qtr FI-l 1799 0-10000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA 15%
Vr-s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s 1
N:tes:
i
i
: 1. Differential pressure is caseilated as, AP = Po - Pi
: 1. Differential pressure is caseilated as, AP = Po - Pi
: 2. Portable vibration instr:nnents are utilized.                                                                                                                                                                                                                                                   ,
[
: 2. Portable vibration instr:nnents are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                                                                                       ;
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
direction on each accessible thrust bearing housing.
{
t i
t i
16-7                                                                                                                                           Rev.0 i
)
16-7 Rev.0 i
i
i
                                                              - - - -          - - - -        . _ - _ . . ~ ~ . _            _ _ _ - - _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ - _ _ - _ - - _. - - -                              .
.. ~ ~.


      .- .          . _ .              .      . . _ -                  . -      . . - . -        -    - . - . . - - - .        . . ~     - - -          .        -      -        - -.          -        . ~ . . - . - -
.. ~
O                                                                                               O                                                                                         O                     .
. ~.. -. - -
i S QMCB                               PI                           gy                         NOTE: THIS IS A SIMPLIFIED HV      PI             1852A                                  1858                                             F1 11803                         DIAGRAM USED TO DEPICT 11800     1878                                                                                                     II79         A TEST CIRCUIT. REFER 14*X10*                           LO LO                            /              '            -                                  '      '                            TO THE P8.ID FOR DETAILS.
O O
                                                                                                                                          'N' 16'                                                                                             030$
O i
16'XI                    .  -1203-P4- 01                                                                         l4, XI   CMPNT. CLG.
S QMCB HV PI 1852A gy NOTE: THIS IS A SIMPLIFIED PI F1 1858 11803 DIAGRAM USED TO DEPICT 11800 1878 II79 A TEST CIRCUIT. REFER 14*X10*
p20'X16'                                                       VATER PUMP HS                                   PI                           HV HV       PI                                                                                                       pg 954                                   1960                         11804 11801     1879                                                                                                     1179                                                 -
LO TO THE P8.ID FOR DETAILS.
14*X10'                             LO LG                                             :            c                   lNl           l     l                                                                     '
LO
16'                                                                                           O 16*X1                       2-1203-P4-003
/
* XI     CMPNT. CLG.
'N' 16' 030$
VATER PUMP                                                                         18*       14'                             '
-1203-P4- 01 16'XI XI CMPNT. CLG.
HS                                   PI                             HV             1179 HV       PI                                                     1862 0 20'X16'             1180     1880               856                                                                11805
l4, p20'X16' VATER PUMP HS PI HV pg HV PI 954 1960 11804 11801 1879 1179 14*X10' LO LG c
                                                                                                                            '                                                                                            CCVS IO' If 16" I,_0 gl                                     lN' (034) f'               l     8*X14'                           COMPONENTS 16'X14"                     2-1203-P4-005
lNl l
          ~ ~
l 16' 16*X1 2-1203-P4-003 O
CMPNT. CLG.                                                                                                                     i ATER PUMP                                                       2'X18, 20'                                                                             (SPARE) b
XI CMPNT. CLG.
                                                                                                                                                                        ~
VATER PUMP 18*
18' 1 li   .
14' HS PI HV 1179 HV PI 1862 11805 856 0 20'X16' 1180 1880 IO' If CCVS I,_0 gl lN' f'
                                                                                                                                                                  ~I'                     LO 4"                                                                                                                                                                                             Hv COMPONENT CLG. VATER                                   11807
l 8*X14' COMPONENTS 16" 16'X14" 2-1203-P4-005 (034)
                          =                                           i p'                                                                 HEAT EXCHANGER                                                                             ,
~ ~
y                     COMPONENT CLG. VATERNLO                                                                                             2-1203-E4-001                                                                         ;
CMPNT. CLG.
SURGE TANK                     )       HV                                                             l_
i ATER PUMP 2'X18, 20' (SPARE) 18' 1 li
2-1203-T4-001                   j         11806 T
~
W               V                                                                                   22'X20' 1866 --                                                                                           TRAIN *A' 9 N Mit WS   iJ.T.E3 f1R PIT I                                       l s e-es-es   as       ets wup to av. se er en sam                             _JC
b
  *  ~         "            """~
~I' LO Hv 4"
Southern Company Services, Inc.FOR Southern Nuclear Operating Company                                   ;
COMPONENT CLG. VATER 11807
VDGTLE ELECTRIC GENERATING PLANT ==* "                                   '*'*"      ''c UNIT 2                     ".mLE empt
=
                                                                                                                                                                                                      " "'" v5 GBff8'EB E'' 3DEZI PUMP INSERVICE TESTING LOOP FOR                                 m                                 n .v.
p' HEAT EXCHANGER i
COMPONENT COOLING VATER PUMP 2-1203-P4 -001                       N/A         N/A     ISI-D- 258             i [F 1 2
y COMPONENT CLG. VATERNLO 2-1203-E4-001 SURGE TANK
)
HV l_
2-1203-T4-001 j
11806 T
W V
22'X20' 1866 --
TRAIN *A'
[
9 N
Mit WS iJ.T.E3 f1R PIT I
l s
e-es-es as ets wup to av. se er en sam
_JC
~
"""~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT==* "
''c UNIT 2
".mLE
" "'" v5 empt GBff8'EB E'' 3DEZI PUMP INSERVICE TESTING LOOP FOR m
n
.v.
COMPONENT COOLING VATER PUMP 2-1203-P4 -001 N/A N/A ISI-D-258 i [F 1 2


O                                                                         O                                                                     O
O O
                                                                      / TIS'\QMCB                   PI                                           NOTE: THIS IS A SIMPLIFIED HV     PI       1853A                                               HV        FI 1859                 11811                       DIAGRAM USED TO DEPICT       i 11808     1881 II79           A TEST CIRCUIT. REFER 14*X10"                   Lo ,
O
a,                                      -                                                          TO THE P8.ID FOR DETAILS 16' 16*X1                 2-1203-P4-002                                                 g4 XI   CMPNT. CLG.
/ TIS'\\QMCB PI HV NOTE: THIS IS A SIMPLIFIED HV PI 1853A FI 1859 11811 DIAGRAM USED TO DEPICT i
1120'X16'                                     02 VATER PUMP QMC PI                   HV 855                       1861                               FI 1882                                                        11812       33797 118 9 14*X10'                   LO VD c             lN'         '  '
11808 1881 II79 A TEST CIRCUIT. REFER 14*X10" Lo,
16'                                                                     E 16*XI                 2-1203-P4-004                                                                 i XI     CMPNT. CLG.
TO THE P8.ID FOR DETAILS a,
VATER PUMP                                                           14'                     t QMC H,                         PI                   HV       1179                                           !
16' 16*X1 2-1203-P4-002 XI CMPNT. CLG.
HV       PI                                   1863 U 20'X16*                   1883         857                                            11813                I '
g4 1120'X16' 02 VATER PUMP QMC PI HV FI 855 1861 11812 118 9 1882 33797 14*X10' LO VD c
18' 11810 14 X10'                   LO                                                 CCVS 16' LD
lN' 16' 16*XI 2-1203-P4-004 E
                                          '    !,'                            %                      O l  18'X14'                         COMPONENTS C
i XI CMPNT. CLG.
* 16*X1                 2-1203-P4 06 CMPNT. CLG.
VATER PUMP 14' t
VATER PUMP 20'                                                         XI     (SPARE) 6 h
QMC H,
_m._       18' i! Ii i        +
PI HV 1179 HV PI 857 1863 11813 I '
                                                                                                                                                                                  )
U 20'X16*
T                 LO 4 ''
11810 1883 18' 14 X10' LO CCVS l
HV COMPONENT CLG. VATER                         11815                       i i   e HEAT EXCHANGER                                                         I y             COMPONENT CLG, VATER LD                                                                   -1203M-002 SURGE TANK                           HV                                         l-2-1203-T4-002                       11814
18'X14' COMPONENTS LD 16' 16*X1 2-1203-P4 06 O
_            T E0 f                                                                       ~
C CMPNT. CLG.
22'X20' 1867 ~ ~~                                                                 TRAIN     'B' e     'a   iza vs   usurs rar est                                 FI i     -es* ms ate wearen To av. se y as4asem                   JJC
VATER PUMP 20' XI (SPARE) 18' i! Ii 6
'                    "~"~
_m._
Southern Company So vices, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT "[58"   "                    *=' =
i
UNIT 2           '"                        "=* w$
+
PUMP INSERVICE TESTING LOOP FOR COMPDNENT CDOLING VATER PUMP
h
: u.      "E U'           r, .
)
2-1203-P4-002           N/A           N/A     ISI-D- 259     I [F 1 2
T LO HV 4 ''
COMPONENT CLG. VATER 11815 i
i e
HEAT EXCHANGER I
y COMPONENT CLG, VATER LD
-1203M-002 SURGE TANK HV l-2-1203-T4-002 11814 T
E0 f
~
22'X20' 1867 ~ ~~
TRAIN
'B' e
'a iza vs usurs rar est FI i
-es*
ms ate wearen To av. se y as4asem JJC
"~"~
Southern Company So vices, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT "[58"
*=' =
UNIT 2
"=* w$
PUMP INSERVICE TESTING LOOP FOR "E U' r,
u.
COMPDNENT CDOLING VATER PUMP 2-1203-P4-002 N/A N/A ISI-D-259 I [F 1 2


O                                                                                   O                                                                       O M QMCB                         pl                   HV                       NOTD THIS IS A SIMPLIFIED HV        PI        1852A                        1858                                 FI 1878                                                          11803                       DIAGRAM USED TD DEPICT 11800                                                                                     1I79         A TEST CIRCUIT. REFER l4'Xl0'                   0 0                                                                                                          TO THE P8.ID FOR DETAILS.
O O
16'        '      I,'
O M QMCB pl HV PI 1852A HV NOTD THIS IS A SIMPLIFIED FI 1858 11803 DIAGRAM USED TD DEPICT 11800 1878 1I79 A TEST CIRCUIT. REFER l4'Xl0' 0
j                  N                l 16*XI                   2-1203-P4-001                                                   g4 XI     CMPNT. CLG.
TO THE P8.ID FOR DETAILS.
Il 20*X16'                                       502 VATER PUMP OHC PI                   HV 1879          854                         1860               11804         jg79 11801 14'X10*                   LD LO                                                   c
0 j
                                                '      I,'
N l
:                  IN:       :1 ll               u 16'                                                                         O 16*XI                   2-1203-P4-003                                                                   i
I,'
_ _ XI     CMPNT. CLG.
16' 16*XI 2-1203-P4-001 XI CMPNT. CLG.
5026 VATER PUMP                                                                   14'
g4 Il 20*X16' 502 VATER PUMP OHC PI HV 854 1860 11804 11801 1879 jg79 14'X10*
                        ~'
LD LO c
O                         HV         PI     QMC h                            PI                    HV          11 9 856                       1862                 11805                             '
IN:
U 20*X16'           1180       1880                                                                                         IB.I      =       CCVS 16' LO 16'XI H                         lNl (034)
:1 ll I,'
[l             l   18'X14'                       COMPONENTS C
u 16' 16*XI 2-1203-P4-003 O
* 2-1203-P4       5 CMPNT. CLG.
i
ATER PUMP 20'                                                                         (SPARE)                                 22'X18*
_ _ XI CMPNT. CLG.
5026 VATER PUMP 14' QMC h PI HV 11 9
~'
O HV PI 856 1862 11805 IB.I U 20*X16' 1180 1880
=
CCVS H
lNl
[l l
18'X14' COMPONENTS LO 16' (034) 16'XI 2-1203-P4 5
C
* CMPNT. CLG.
ATER PUMP 20' (SPARE) 22'X18*
18' iI Ii
~
h
h
_a_
_a_
                                                                                                                                          ~
n T
                                                                                                                                          -          18'. iI Ii n T                     LD 4"                                                                                                                                                             HV COMPONENT CLG. VATER                           11807 i
LD 4"
i
HV COMPONENT CLG. VATER 11807 HEAT EXCHANGER i
                                                                    '                                                HEAT EXCHANGER y                  COMPONENT CLG. VATER                   0                                                     2-1203-E4-001 SURGE TANK                               HV                                         3-2-1203-T4-001 W                -
i y
11806
COMPONENT CLG. VATER 0
                                                                                                        -            T V                                                                       22'X'20' 1866 ~-                                                                   TRAIN     'A'
2-1203-E4-001 SURGE TANK HV 3-2-1203-T4-001 11806 T
_            _,                          ._                            _. _. _.      _. _s   -
W V
9    FM     EiB VE       ESED f1R PST                                       -I a   e     as   als     irsarts to av . r emessim                       . JC
22'X'20' 1866 ~-
*                          "~"~
TRAIN
Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT     "S**     "                = ==
'A'
UNIT 2                ""'                      ==* vi
_s 9
                                                                                                                                                      ~
FM EiB VE ESED f1R PST
DUMP INSERVICE TESTING LOOP FOR COMPONENT COOLING VATER PUMP
-I a
                                                                                                                                                            -.          ~ECC'        ,,o,  .
e as als irsarts to av. r emessim
2-1203-P4-003              N/A        N/A      ISI-D- 260    1 (1r 1  2
. JC
"~"~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT "S**
 
===
UNIT 2


O                                                                      O                                                                                                                                                        O                          >
==* vi DUMP INSERVICE TESTING LOOP FOR
M OMCB                                                                    pr                                              gy                      NOTE: THIS IS A SIMPLIFIED HV        PI      1853                                                            1859                                                                      FI          DIAGRAM USED TO DEPICT 11811 11808    1881                                                                                                                                                1179        A TEST CIRCUIT. REFER 14*X10*                                                                                              LD                              TO THE PLID FDR DETAILS.
~ECC'
LD                                          c                                                                                                    '    '
,,o,
l    l,            D-i l
~
14' lN' 16,              i 16*X14*            2-1203-P4-002                                                                                  @
COMPONENT COOLING VATER PUMP 2-1203-P4-003 N/A N/A ISI-D-260 1 (1r 1 2
g4, XI    CMPNT. CLG.
1120'X16'                                  5025 VATER PUMP "h855                                                          1861 PI                                                HV 11812 FI 11809    1882                                                                                                                                                11797                                                        I 14*X10'                                                                                              LO LO
:    c                                                                                      lN            l    l                    -
16' 16*X1              2-1203-P4-004                                                                                O                                                                i XI    CMPNT. CLG.
VATER PUMP QMC PI                                                          HV          1179 HV        PI                                                            1863 U 20'X16'                    1883        857                                                                                                                      11813                        gg, 11810 CCVS l-18'X14' 16' LO
                                            !    N                          H                                                                                                IN'          fi                                                    COMPONENTS              ,
              =
16*X1              2-1203-P4                              6                                                                                                                                                  -i CMPNT. CLG.
ATER PUMP 20'                                                              (SPARD                                                                                                              22'X18'                                                              '
18'ij ge    ,
H                                                                                                                                                                                            T                    LD HV 4'
COMPONENT CLG. VATER                                  11815                                      ,
sp  i                                                                                                                  HEAT EXCHANGER                                                                            _'
y              COMPONENT CLG. VATER LD SURGE TANK                          HV                                                                                                              l-
* T 2-1203-T4-002                        11814 U  EO f                                                              22'X20' L                                                                1867 --                                                                                                                                                    TRAIN *B'
.  --      -  .,         nm                                      ei i  e-es-as  et  ats  tranrts a uv. se r exassin                  JJC
*          *        " " " " ~
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT **e                                                                        "                    ''=      ''c UNIT 2                '""*                        " " vs PUMP INSERVICE TESTING LOOP FOR                                                                                  mus            "EU'                x, .
COMPONENT CDOLING VATER PUMP 2-1203-P4-004                  N/A         N/A         ISI-D- 261        1 [F 1 2 t


                  %                                                                          (                                                                             lh Y                                                                                                                                                           Y PI                           Hy                       NOTE: THIS IS A SIMPLIFIED HV      PI                                                                                      }
O O
11800    1878 1858                     11803           gg79 MGM M TD DMCT
O M OMCB pr gy NOTE: THIS IS A SIMPLIFIED HV PI 1853 FI DIAGRAM USED TO DEPICT 1859 11811 11808 1881 1179 A TEST CIRCUIT. REFER 14*X10*
                                                                        '                  14'X10                                                          A TEST CIRCUIT. REFER LO                                        e
LD TO THE PLID FDR DETAILS.
                                                                                              ~              'qi' e            hO     ,                          TO THE PLID FOR DETAILS.
LD l
6*        !    !!            N                             14' 16*X14'               2-1203-P4-001             O XI                                                                           I4' CMPNT. CLG.
c lN' l
H 20*X16'                                     5024' VATER PUMP PI                         HV
l, D-i 14' i
                                                                                                    ,1860                     11804 11801   1879                                                                                 1179 14*X10*                       LO
16, 16*X14*
                                            'O                                       :      c               lN:         '
2-1203-P4-002 g4, XI CMPNT. CLG.
16'      '    Ii'            M                             14*
1120'X16' 5025 VATER PUMP "h
O 16'X14'               2-1203-P4-003                                                                           ,
PI HV FI 855 1861 11812 11809 1882 11797 I
XI     CMPNT. CLG.
14*X10' LO LO c
5026 VATER PUMP                                                                         14 DMC                                                                           FI HS                             P1                         HV           1179 HV       PI                                     1862 N20*X16*           1180     1880                                                                 11805            --
lN l
If yg,1I 14*X10'                       LD r        CCVS 16, fu,                                 y.4l             ,
l 16*X1 2-1203-P4-004 O
E
16' i
                                                                                                              ;q;         e
XI CMPNT. CLG.
                                                                                                                                ;        l  18'X14*                      COMPONENTS 16'X14*               2-1203-P4-005
VATER PUMP QMC PI HV 1179 HV PI 1863 11813 857 U 20'X16' 11810 1883 gg, CCVS LO H
      '~__
IN' fi l-18'X14' COMPONENTS N
16' 16*X1 2-1203-P4 6
-i
=
CMPNT. CLG.
ATER PUMP 22'X18' 20' (SPARD 18'ij ge H
T LD HV 4'
COMPONENT CLG. VATER 11815 sp HEAT EXCHANGER i
y COMPONENT CLG. VATER LD SURGE TANK HV l-2-1203-T4-002 11814 T
U EO f
22'X20' L
1867 --
TRAIN *B'
)
nm ei i
e-es-as et ats tranrts a uv. se r exassin JJC
" " " " ~
Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT **e
''=
''c UNIT 2
" " vs PUMP INSERVICE TESTING LOOP FOR "EU' x,
[
mus COMPONENT CDOLING VATER PUMP 2-1203-P4-004 N/A N/A ISI-D-261 1 [F 1 2 t
 
(
lh Y
Y PI HV PI Hy NOTE: THIS IS A SIMPLIFIED
}
1858 11803 MGM M TD DMCT 11800 1878 gg79 A TEST CIRCUIT. REFER 14'X10 hO TO THE PLID FOR DETAILS.
LO
'qi e
e N
14'
~
6*
16*X14' 2-1203-P4-001 O
XI CMPNT. CLG.
I4' H 20*X16' 5024' VATER PUMP PI HV
,1860 11804 11801 1879 1179 14*X10*
LO
'O c
lN:
Ii M
14*
16'X14' 2-1203-P4-003 O
16' XI CMPNT. CLG.
5026 VATER PUMP 14 DMC FI HS P1 HV 1179 HV PI 1862 11805 If yg,1I N20*X16*
1180 1880 r
CCVS 14*X10' LD l
18'X14*
COMPONENTS fu, y.4l
;q; e
16,
'~__
16'X14*
2-1203-P4-005 E
CMPNT.CLG.
CMPNT.CLG.
ATER PUFP 20'                                                                 (SPARE)                                           22*X18' i
ATER PUFP 22*X18' 20' (SPARE) 18'.iI la i
_i_ -
_i_
18' .iI  la a
a T
___                      T                    LO 4'                                                                                                                                                             HV COMPGNENT CLG. VATER                               11807
LO 4'
                                                        '  '                                                    HEAT EXCHANGER jf              COMPONENT CLG. VATER LD                                                                       2-1203-E4-001 SURGE TANK                         HV                                               _1_
HV COMPGNENT CLG. VATER 11807 HEAT EXCHANGER j f COMPONENT CLG. VATER LD 2-1203-E4-001 SURGE TANK HV
2-1203-T4-001                       11806 T
_1_
1f                                                                   22*X20'
2-1203-T4-001 11806 T
                =                                                               TE LD                                                                   1866 PES                                                                         ,
1f 22*X20'
am       e, a==                         m-_._                     ,    ,    . m. ms 9 77 %   EE   vt   13SE3 FIR PST                               fI                                                                         *
=
  ,-as e et   ets i
TE LD 1866 PES e
waarts is arv. se y emessem                 .1C
am e,
                    ~~"~
a==
Southern Company Services. Inc.FOR Southern Nuclear OperoHng Company VDGTLE ELECTRIC GENERATING PLANT - "                                   =     =c UNIT 2                 '"
m-_._
g, y_,
m.
PUMP INSERVICE TESTING LOOP FDR                             a.       -              , o COMPONENT COOLING VATER PUMP 2-1203-P4-005                   N/A         N/A     ISI-D- 262   I [F 1 2
ms 9
77 %
EE vt 13SE3 FIR PST fI i
,-as e et ets waarts is arv. se y emessem
.1C
~~"~
Southern Company Services. Inc.FOR Southern Nuclear OperoHng Company VDGTLE ELECTRIC GENERATING PLANT - "
=
=c UNIT 2 g, y_,
PUMP INSERVICE TESTING LOOP FDR a.
o COMPONENT COOLING VATER PUMP 2-1203-P4-005 N/A N/A ISI-D-262 I [F 1 2
 
O O
O
/ TIS'\\0MCB PI HV NOTE: THIS IS A SIMPLIFIED HV PI 853 FI DIAGRAM USED TO DEPICT 1859 11811 11808 1881 1179 A TEST CIRCUlT. REFER 14*X10" LO TO THE PLID FOR dei.c,ILS.
LO c
lN 16' O
16'X1 2-1203-P4-002 g4, XI CMPNT. CLG.
1120'X16" 5025 VATER PUMP 0" h PI Hy HV PI FI 1861 11812 gg797 gg 9 18g2 855y 14*X10' LO LO
.N'
~
16*XI 2-1203-P4-004 E
16' XI CMPNT CLG.
VATER PUMP H
P1 HV 1179 L,
HV PI 1863 11813 gg. I I 857 O 20*X16' 11810 1883 CCVS 14*X10' LO l
18'X14' COMPONENTS O
K' 16*
16*X1 2-1203-P4 06 O
C O CMPNT. CLG.
ATER PUMP 22*X 8' 20' (SPARE) 18',ig gi h
T LD HV 4'
COMPONENT CLG. VATER 11815 ig HEAT EXCHANGER i
y COMPONENT CLG. VATER LO
~
~ ~
SURGE TANK HV I-2-1203-T4-002 11814 T
W10 22'X'20' L
1867 --
TRAIN
'B' e
,+=
su vs nuns nsi ne ti n
e-m-es ca.
sta tenarts to av. a. r asesoim JJC
"~"~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT==' "
UNIT 2


O                                                                                                                                                        O                                                                            O
=== vs PUMP INSERVICE TESTING LDDP FDR ua C h"'
                                                                                                                                                / TIS'\0MCB                      PI                                                  NOTE: THIS IS A SIMPLIFIED PI                                          853                                                      HV          FI HV                                                                                                                  1859                        11811                      DIAGRAM USED TO DEPICT 11808                                        1881                                                                                                                    1179        A TEST CIRCUlT. REFER 14*X10"                          LO                            TO THE PLID FOR dei.c,ILS.
COMPONENT CDOLING VATER PUMP 2-1203-P4-006 N/A N/A ISI-D-263 1 [F 1 2
LO                                                                                                                    :    c                lN              :
16'        !
16'X1                                                  2-1203-P4-002            O                                            g4, XI    CMPNT. CLG.
1120'X16"                                                                                                                5025 VATER PUMP HV                                          PI                    0" h                                              PI 1861 Hy 11812 FI gg 9                                        18g2                                              855y                                                                  gg797 14*X10'                          LO LO                                                                                                                                                            '    '
                                                                                                                                                                  .    ~                .N' 16' 16*XI                                                    2-1203-P4-004          E
* XI    CMPNT CLG.
VATER PUMP H                          P1                          HV          1179 L,                              HV                                          PI                                                                      1863 O 20*X16'                                                        1883                                              857                                                    11813                        gg. I I 11810 14*X10'                          LO                                                  CCVS O                                                                                                                                        ,    ,                ,        l  18'X14'                      COMPONENTS
                                          '        '!,'                                                                                                    K' C O 16*                                                                16*X1                                                    2-1203-P4 06              O CMPNT. CLG.
ATER PUMP 20'                                                                                                                                                (SPARE)                                          22*X 8' 18' ,ig  gi h                                                                                                                                                                                                          T                  LD 4'
HV COMPONENT CLG. VATER                                11815 ig i
HEAT EXCHANGER
                                                                                                                                                                                              ~    ~ ~
y              COMPONENT CLG. VATER LO SURGE TANK                                                                          HV                                                                      I-W10 2-1203-T4-002                                                                        11814
                                                                                                                                                                          -              T 22'X'20' L                                                                                                                                                1867 --                                                                          TRAIN 'B' e  ,+=    su  vs  nuns nsi ne                                                                                                  ti n  e-m-es  ca. sta  tenarts to av. a. r asesoim                                                                              JJC
*                  "~"~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT ==' "                                "
* UNIT 2                  '"'                    === vs PUMP INSERVICE TESTING LDDP FDR                           ua       C h"'       -,
COMPONENT CDOLING VATER PUMP 2-1203-P4-006                     N/A       N/A     ISI-D- 263   1 [F 1 2


4
4 SIPumps (2-1204-P6-003, & 004)
'                                          SIPumps (2-1204-P6-003, & 004)
System Function
]
]
4
System Function The SI system provides emergency core cooling and serves 4
                              ,      The SI system provides emergency core cooling and serves no other purpose.
no other purpose.
                                                                                                'l The primary function of the ECCS is to remove the stored l                                    and fission product decay heat from the reactor core j
'l l
The primary function of the ECCS is to remove the stored and fission product decay heat from the reactor core j
following an accident in order to prevent fuel rod damage.
following an accident in order to prevent fuel rod damage.
!                                                                                              i Quantity                       2 Type Horizontal, centrifugal,11-stage s                                                                                               !
i Quantity 2
4 Manufacturer /Model           Paci6c Model 3-ht., JHF Rated Capacity                 440 gpm Rated Head                     2630 ft.
Type Horizontal, centrifugal,11-stage s
Driver Type Electric Motor, Westinghouse, Frame 5809 H Horsepower               450 Speed                     3600 rpm Power Supply             4160V,60 Hz,3 phase Code Class                     2 Project Class                 212 Outline Drawing               2X6AG02-10,13 & 15                                           i Instruction Book             2X6AG02-016 Physical Location Aux Bldg, Level B, Rooms R-B117 & R-B119 P&ID                         2X4DB121 Surveillance Procedure       14804-2 Pump Test Loop Diagrams     ISI-D-264 & ISI-D-265 Test Parameter Sheets       Page 17-2 & 17-3 D
Manufacturer /Model Paci6c Model 3-ht., JHF 4
17 - 1                               Rev.O
Rated Capacity 440 gpm Rated Head 2630 ft.
Driver Type Electric Motor, Westinghouse, Frame 5809 H Horsepower 450 Speed 3600 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2
Project Class 212 Outline Drawing 2X6AG02-10,13 & 15 Instruction Book 2X6AG02-016 Physical Location Aux Bldg, Level B, Rooms R-B117 & R-B119 P&ID 2X4DB121 Surveillance Procedure 14804-2 Pump Test Loop Diagrams ISI-D-264 & ISI-D-265 Test Parameter Sheets Page 17-2 & 17-3 D
17 - 1 Rev.O


o                                                                           '
o O
O                 ,
i Test ParameterTable - Pump 2-1204-P6-003 (Figure ISI-D-264)
i Test ParameterTable - Pump 2-1204-P6-003 (Figure ISI-D-264)
Instrumentation Utilized           Ref.         Acceptable     Alert             Action Parameter         Test Freq.       I.D. No.f3)   Range           Rea. Acc. Value         Range           Range             Range               Comments Speed (N)                 NA             NA             NA             NA         NA           NA             NA               NA                 Constant speed driver               s Inlet Pressure           Qtr             PI-0977       0-100           i2%       NA           NA             NA               NA                 NA                                   i (Pi)                                               psig Outlet Pressure           Qtr             Test           NA             12%       NA           NA             NA               NA                 NA                 i                 i (Po)                               Gage Differ.
Instrumentation Utilized Ref.
Pressure           Qtr             NA(1)         NA             i2%       APr           .90 - 1.10APr   NA               <.90 or >l.10APr NA                                     l (AP)                                                                                                                                                                                   i t
Acceptable Alert Action Parameter Test Freq.
Flowrate           Qtr             FI-0968       0-100           i2%       Qr           NA             NA               NA                 Flowrate is set at reference value
I.D. No.f3)
                                                                                                                                                                                            ~
Range Rea. Acc.
(Q)                                               gpm Vib.
Value Range Range Range Comments Speed (N)
Amp.               Qtr             (2)           NA             i5%         Vr           s 2.5Vr         > 2.5Vr - 6Vr   >6Vr or             NA                                   l (V)(4)                                                                                                     or >.325 in/s   >.70 in/s                                                 ;
NA NA NA NA NA NA NA NA Constant speed driver s
i
Inlet Pressure Qtr PI-0977 0-100 i2%
                                                                                                                                                                                            ^
NA NA NA NA NA i.
(Pi) psig Outlet Pressure Qtr Test NA 12%
NA NA NA NA NA i
i (Po)
Gage Differ.
Pressure Qtr NA(1)
NA i2%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA l
(AP) i t
Flowrate Qtr FI-0968 0-100 i2%
Qr NA NA NA Flowrate is set at reference value p
(Q) gpm
~
Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA l
(V)(4) or >.325 in/s
>.70 in/s i.
Notes:
Notes:
^
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial           ;
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
direction on each accessible thrust bearing housing.
i 17-2 Rev.O
i 17-2                                                               Rev.O


                                ~. _ ._ . .._ ____ _. _                         _.m   . _ _ ._ __ _ _. _                _ . _ . _ . _ .- _ ..        _ . - . . _ .
~. _._..._ ____ _. _
Test ParameterTable _- Pump 2-1204-P4-004
_.m Test ParameterTable _- Pump 2-1204-P4-004
                                                                                              ' (Figure ISI-D-265)
' (Figure ISI-D-265)
Instruments. lion Utilized             Ref.       Acceptable   Alert                 Action Earameter           Test Frea.           1.D. No.(3)       Range           Rea. Ace.     Value       Range         Range                 Rance                   Comments Speed (N)                 NA                 NA                 NA             NA             NA         NA           NA                   NA                     Constant speed driver inlet
Instruments. lion Utilized Ref.
' Pressure           Qtr                 PI-0978             0-100         12%             NA         NA           NA                   NA                       NA (Pi)                                                       psig Outlet Pressure           Qtr                 Test               NA             12%           NA           NA           NA                   NA                       NA                 i (Po)                                   Gage Differ.
Acceptable Alert Action Earameter Test Frea.
Pressure           Qtr                 NA(1)               NA             12%           APr         .90 - 1.10APr NA                   <.90 or >l.10APr NA (AP)
1.D. No.(3)
Flowrate           Qtr                 FI-0968             0-100         12%           Qr           NA           NA                   NA                       Flowrate is set at reference value (Q)                                                         gpm Vib.
Range Rea. Ace.
Amp.               Qtr                 (2)                 NA             i5%           Vr           s 2.5Vr       > 2.5Vr - 6Vr       >6Vr or                 NA (V)(4)                                                                                                               or >.325 in/s       >.70 in/s Notes:
Value Range Range Rance Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver inlet
' Pressure Qtr PI-0978 0-100 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr Test NA 12%
NA NA NA NA NA i
(Po)
Gage Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr FI-0968 0-100 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
17 - 3                                                                   Rev.0
17 - 3 Rev.0


                          /G                                                                                                 Og U                                                                                                  V                                                                                                                    [''N U l NOTE: THIS IS A SIMPLIFIED                                                                                                                                                           VPS REAC DIAGRAM USED TO DEPICT                                           M"               HV             3'X3/4"       CVCS BA BLENDER 2,                ,
/G Og
C      CDDL DRAIN g? [If2,@ I fIf (0.02)
[''N U
A TEST CIRCUlT. REFER                                                                             O                 CSS TEST LINE                                                 TANK PUMP 00 TO THE P&ID FOR DETAILS.                                           8964 ~ k' 8964                          jf                                                                                        ,                                                                        ,
V U l NOTE: THIS IS A SIMPLIFIED VPS REAC DIAGRAM USED TO DEPICT M" 2,
SIS   BORON INJECTIONj 3/4" "FC'
HV 3'X3/4" CVCS BA BLENDER C
                                                                                                                                                                                              ~
CDDL DRAIN
TEST LINE                                                                               O                                                                                                            REFUELING VATER HV                               SFPCS                                                           PCP STORAGE TANK HS MCB                           8813 09 8                PURIF       ;;      3'
? [ 2, A TEST CIRCUlT. REFER O
                                                                                                                                                                                                                                                                        ~'
CSS TEST LINE 8964 ~ k' 8964 jf 00 TANK PUMP g If @ I fIf (0.02)
8888                                                                 PUMP       (003)                               807       1     0
TO THE P&ID FOR DETAILS.
                                                        !                        813       M         3'X2'                                                                         HV i                                                    HV                                                                     807 H                                       t. --
SIS BORON INJECTIONj 3/4" "FC'
QMCB                                                                                         "
~
(FC                          3'X11/2 8814 HV                                                                   OMCB                                       >,
REFUELING VATER O
8888                                                                                                                                                                                       ,
TEST LINE HV SFPCS PCP STORAGE TANK HS MCB 8813 PURIF 3'
r                                                        M                                                                     MCB 802     k                                     L               3/4' LOCAL         C 3/4-1 1/2*
09 8
8814 6,                       07B            H CVCS CHARGING N
~'
QM B HV 4'
8888 PUMP (003) 807 1
b                    093 MCB 9                          Hv A
0 813 M
                                                                                                        -                        HS                            M                 g0 B QHCB                                                                                                           X11/2'        999         pg               g23 H                                                         (100 )       (098)                                                                                       >,                                                                                            24' 4
3'X2' HV HV 807 i
* X3,         ,        0977        UM OI LD                 3'X11/2'       2-1204-P6-003 D          b^
(FC H
6-(207 SIS COLD                                                   s                                  SAFETY INJECTION LEG LOOP _4'                                         / PI T                                                               XI           TI                                 H                 L                 HV H                        PUMP                                                                                                  8806 HV                                                               8920     M           TRAIN *A.                                                         LO         135                                                                                   QMCB 821B                                               MCB QMCB      gy                                                                           8'X6'         WO                         M                                               8806 821B         M                                                                                                                   "
: t. --
QMCB 3'X11/2 8814 HV OMCB 8888 r
M MCB 3/4-8814 CVCS CHARGING 802 k
L 3/4' LOCAL 07B H
N C
1 1/2*
6, b
QM B 4'
093 9
HV MCB Hv HS A
X11/2' M
g0 B QHCB 999 g23 pg 24' H
(100 )
(098) 0977 UM OI 4
* X3, D
b^
(207 LD 3'X11/2' 2-1204-P6-003 6-SIS COLD LEG LOOP _4'
/ PI T H
PUMP XI TI s
SAFETY INJECTION H
L HV 8806 HV 8920 M
TRAIN *A.
LO 135 QMCB 821B MCB gy 8'X6' WO M
QMCB 8806 821B M
HV
HV
  -QMCB       HV                                                                                                                             PI               923 802                                               101 )       (099)                                                                                     Luh136) 1 1/2' h          4,   4'X3,                       OW8 8
-QMCB HV PI 923 Luh136) 802 101 )
H r            LO                               2-1204-P6-004                   i     "
(099) h OW8 1 1/2' 4,
6,           >
4'X3, H
s L                                           SAFETY INJECTION                                                               (163)
8 r
CMCB                               4' TRA N *B'                                               8'
LO 2-1204-P6-004 i
: e.   .m       e,                         o.,
6, (163) s L SAFETY INJECTION CMCB 4'
                                                                                                                                                                                                  " ' R R HEAT EXCH NGER-
TRA N *B' 8'
                                                                          --                    -.4   -u   -.2     m.     -s   =====
" ' R R HEAT EXCH NGER-e.
. we.-   ==                                vs    unrsrm m                                    tI e-es-es a            ca-                              .ts    woms a uv. es or exesem                    JJC Southern Company Services, Inc.rOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT ==* "                                                **                                          "c UNIT e                  ---
.m e,
                                                                                                                                                                                      ,                        < , ,,,, y ,,,,
o.,
PUMP INSERVICE TESTING LOOP                            ,.au.                , ,                                                  .    , , , ,  .
-.4
FOR SAFETY INJECTION PUMP 2-1204-P6-003                    N/A          N/A              ISI-D- 264                                                  iT1 2
-u
-.2 m.
-s
 
=====
we.-


                                                                                                                    /
==
p Q ,)                                                                                                                                                 ]
vs unrsrm m tI a
NOTE: THIS IS A SIMPLIFIED                                                                                                                                                                 VPS REAC DIAGRAM USED TO DEPICT                               M MCB HV                           3'X3/4"         CVCS BA BLENDER E,    ^        2, ' '
e-es-es ca-
COOL DRAIN A TEST CIRCUIT. REFER                                 8964
.ts woms a uv. es or exesem JJC Southern Company Services, Inc.rOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT==* "
                                                                                            ~
"c UNIT e
CSS TEST LINE               7;2                                         TANK PUMP y y Q03) 0 TO THE P8.ID FOR DETAILS.                                         k'8964                              y                                 gy                                                                                                                                     _
<,,,,, y,,,,
SIS BORON INJECTIONj 3/4' 'pC' TEST LINE                                                                    N                                                 jl REFUELING VATER HV                                  SFPCS                                                QM B                                       PCP STORAGE TANK M MCB                               8813 09 8                PURIF       ;;        3'                             HS3 TS                                                                               2-204 -T4-001 813       M           3'X2' HV H
PUMP INSERVICE TESTING LOOP
,.au.
FOR SAFETY INJECTION PUMP 2-1204-P6-003 N/A N/A ISI-D-264 iT1 2
 
/
p Q,)
]
NOTE: THIS IS A SIMPLIFIED VPS REAC DIAGRAM USED TO DEPICT M MCB E,
^
2, ' '
HV 3'X3/4" CVCS BA BLENDER COOL DRAIN A TEST CIRCUIT. REFER 8964 CSS TEST LINE 7;2 k'8964
~
Q03)
TANK PUMP 0
TO THE P8.ID FOR DETAILS.
y gy y y SIS BORON INJECTIONj 3/4' 'pC' REFUELING VATER N
jl QM B PCP TEST LINE HV SFPCS STORAGE TANK M MCB 8813 PURIF 3'
HS3 TS 2-204 -T4-001 09 8 813 M
3'X2' HV HV (FC 807 H
t---
t---
HV                                                                      807 (FC          QMCB               3'X11/2 8814 HV                                                                                                                       '
QMCB 3'X11/2 8814 HV QMCB r
QMCB r                                                                   M                                                                       M 802   k                     k                  3/4       LOCAL
M M
                                                                  ^"    WM 3/4' 1 1/2*
802 k
8814 6                             07B                                                 H NMP CVCS CHARGING QMCB                 4'                                                 @                        093)                                       3 HV                                                                                                                                                               H 821A                                                                     3'       ,_M3*X11/2,           M MCB                            HV                   gO B QMCB                                                                                           /                                 pj               923                                                                                                                 4, 4*X ,          ,        0977                                >,
3/4' 8814 CVCS CHARGING k
821A      M LO                   3"X11/2"         2-1204-P6-003                 0     ;
3/4 LOCAL WM 1 1/2*
                                                                                                                                              )
6 07B H NMP
SIS COLD 4                                 -%                                      SAFETY INJECTION 6'
^"
LEG LOOP                                 / PI \                                                                 XI           TI                                     h                                                    L                              HV PUMP                                                                                                                                                    1 8806 H                                                     8920     M               TRAIN *A.                                                       LO             135)                                                                                         QMCB QMCB   - HV                                                                             8'X6*                   090                                                                       M     8806 821B     M                                                                 <-
QMCB 4'
MCB QMCB      HV                                                                                                                      PI                923 802                                                  (099)                                                                                       LD 1 1/2*                       4*X3,                     0978 4,                                                                                                                                                          HV HS                                           LO                                 2-1204-P6-004                     0 Ms                                                                                                                                D P
093) 3 H
802                         L                                                SAFETY            ECTION 6,
HV M MCB 821A 3'
,_M3*X11/2, HV gO B QMCB
/
pj 923 4,
0977 821A M
4*X,
LO 3"X11/2" 2-1204-P6-003 0
)
6' SIS COLD 4 SAFETY INJECTION h
L HV LEG LOOP
/ PI \\
PUMP XI TI 1 8806 H
8920 M
TRAIN *A.
LO 135)
QMCB QMCB
- HV 8'X6*
090 M
8806 MCB 821B M
(099)
PI 923 QMCB HV LD 802 0978 1 1/2*
4, 4*X3, HV HS P
LO 2-1204-P6-004 0
D 802 Ms 6,
(163)
(163)
QMCB               4*
L SAFETY ECTION QMCB 4*
: e.   ==     =           o.s                                 ----.                    ,,.a yp g
"'RhRHEATEXHNGER D
                                                                                              . , =
yp g
                                                                                                    ,B'
,B' 8"
                                                                                                    .m.      .
e.
D .-,  .-
 
8"
==
                                                                                                                                                                                                                                "'RhRHEATEXHNGER e    **-  =:             vi             naza rm en                                   t1
=
      **as ca             ==
o.s
i temen in uv. ee y ensam                   JJC
,,.a
            *                            '~*~
., =
.m.
e
=:
vi naza rm en t1 i
**as ca
 
==
temen in uv. ee y ensam JJC
'~*~
Southern Company Services. Inc.FOR Southern Nuclear Operoling Company V0GTLE ELECTRI EgERATING PLANT =_5='
Southern Company Services. Inc.FOR Southern Nuclear Operoling Company V0GTLE ELECTRI EgERATING PLANT =_5='
                                                                                                                                                                                    ~
_=
_=   '
=
                                                                                                                                                                                                                                                                      =
~
PUMP INSERVICE TESTING LUDP                                                                             ua                                         u   a FOR SAFETY INJECTION PUMP 2-1204-P6-004                         N/A                                         N/A                                 ISI-D- 265     1 [F 1 2
PUMP INSERVICE TESTING LUDP ua u
a FOR SAFETY INJECTION PUMP 2-1204-P6-004 N/A N/A ISI-D-265 1 [F 1 2


l i                                                                                                                                               .
l i
RHR Pumps j
RHR Pumps j
(2-1205-P6-001, & 002)                                                                 i System Function O'                                        ~
(2-1205-P6-001, & 002) i O'
The primary function is to remove heat energy from the reactor core and reactor coolant system during plant cooldown and refueling operadons. As a secondary                                   '
System Function
function, RHR is used to transfer refueling water between the refueling water storage tank and the refualing cavity at the begin. ing and end of refueling operations.                                     i Portions of the RHR system also serve as part of the ECCS during the injection and recirculation phases of a LOCA.
~
Quantity                                       2 Type Vertical, centrifugal, single stage Manufacturer /Model                           Ingersoll-Dresser,8X20WDF Rated Capacity                               3000 gpm                                                                             '
The primary function is to remove heat energy from the reactor core and reactor coolant system during plant cooldown and refueling operadons.
Rated Head                                   375 ft.
As a secondary function, RHR is used to transfer refueling water between the refueling water storage tank and the refualing cavity at the begin. ing and end of refueling operations.
Driver                                                                                                                             I g               Type Westinghouse LLD squirrel-cage induction motor i                 Horsepower                         400 Speed                              1780 rpm
i Portions of the RHR system also serve as part of the ECCS during the injection and recirculation phases of a LOCA.
Quantity 2
Type Vertical, centrifugal, single stage Manufacturer /Model Ingersoll-Dresser,8X20WDF Rated Capacity 3000 gpm Rated Head 375 ft.
Driver I
g Type Westinghouse LLD squirrel-cage induction motor i
Horsepower 400
(
(
Power Supply                                                                                                             :
Speed 1780 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2
4160V,60 Hz,3 phase Code Class                                     2 Project Class                                 212 Outline Drawing                               AX6AF02-20007 Instruction Book                             AX6AF02-20030 PhysicalLocation                             Aux Bldg, Level D, Rooms R-D21 & R-D22 P&ID                                         2X4DB122 Surveillance Procedure                         14805-2 & 14812-2 Pump Test Loop Diagrams                       ISI-D-266 & ISI-D-267
Project Class 212 Outline Drawing AX6AF02-20007 Instruction Book AX6AF02-20030 PhysicalLocation Aux Bldg, Level D, Rooms R-D21 & R-D22 P&ID 2X4DB122 Surveillance Procedure 14805-2 & 14812-2
                                                                                                                                                )
)
Test Parameter Sheets                         Page 18-2 & 18-3 O
Pump Test Loop Diagrams ISI-D-266 & ISI-D-267 Test Parameter Sheets Page 18-2 & 18-3 O
18 - 1                                         Rev.0 1
18 - 1 Rev.0 1


s J                                                               a Test Parameter Table - Pump 2-1205-P6-001 (Figure ISI-D-266)
s J
Instrumentation Utilized                                                                   Ref.                                           Acceptable   Alert         Action Parameter         Test Freq.       I.D. No.(31     Range         Req. Acc. Value                                                                                                   Range       Range         Range           comments Speed (N)               NA               NA             NA           NA                                                                 NA                                             NA           NA           NA               Constant speed driver inlet Pressure           Qtr             PI-8884         0-100         12%                                                               NA                                             NA           NA           NA               NA (Pi)                                               psig Outlet Pressure           Qtr             PI-8886         0-400       12%                                                                 NA                                             NA           NA           NA               NA                 i (Po)                                               psig Differ.
a Test Parameter Table - Pump 2-1205-P6-001 (Figure ISI-D-266)
Pressure           Qtr             NA(1)           NA           i2%                                                               APr                                             .90 - 1.10APr NA           <.90 or >l.10APr NA (AP)
Instrumentation Utilized Ref.
Flowrate           Qtr             F1-0618A       0-5000       12%                                                               Qr                                             NA           NA           NA               Flowrate is set at reference value (Q)                                                 gpm Vib.
Acceptable Alert Action Parameter Test Freq.
Amp.               Qtr             (2)             NA           i5%                                                               Vr                                             s 2.5Vr       > 2.5Vr - 6Vr >6Vr or         NA (V)(4)                                                                                                                                                                                           or>.325 in/s >.70 in/s Notes:
I.D. No.(31 Range Req. Acc. Value Range Range Range comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-8884 0-100 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8886 0-400 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA i2%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr F1-0618A 0-5000 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or>.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
Rev.0 18 -2
18 -2 Rev.0


O                                                                                                                                                                                 O                                                                                                                                                               O Test Parameter Table - Pump 2-1205-P6-002 (Figure ISI-D-216)
O O
Instrumentation Utilized                                                             Ref.                                                                   Acceptable                     Alert           Action                                                                                                                 ;
O Test Parameter Table - Pump 2-1205-P6-002 (Figure ISI-D-216)
Parameter                 Test Freg,             I.D. No.0)       Range         Reedcc. Value                                                                                                                     Bange                         Range           Range                                                                         Comments                                 i Speed (N)                       NA                     NA               NA             NA                                                         NA                                                                     NA                             NA               NA                                                                             Constant speed driver Inlet Pressure                   Qtr                   PI-8885         0-100         12%                                                         NA                                                                   NA                             NA               NA                                                                             NA (Pi)                                                               psig Outlet Pressure                   Qtr                   PI-8887         0-400           12%                                                         NA                                                                   NA                             NA               NA                                                                             NA                 i (Po)                                                               psig
Instrumentation Utilized Ref.
. DitTer.                                                                                                                                                                                                                                                                                                                                                                                     ,
Acceptable Alert Action Parameter Test Freg, I.D. No.0)
Pressure                   Qtr                   NA(1)           NA             12%                                                       APr                                                                   .90 - 1.10APr                   NA               <.90 or >l.10APr NA (AP)
Range Reedcc. Value Bange Range Range Comments i
Flowrate                   Qtr                   FI-0619A       0-5000         12%                                                       Qr                                                                   NA                               NA               NA                                                                             Flowrate is set at reference value gpm                                                                                                                                                                                                                                                                                                                        i (Q)
Speed (N)
Vib.
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-8885 0-100 12%
Amp.                       Qtr                   (2)             NA             i5%                                                       Vr                                                                   s 2.5Vr                         > 2.5Vr - 6Vr   >6Vr or                                                                       NA                                       ,
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8887 0-400 12%
(V)(4)                                                                                                                                                                                                                                             or >.325 in/s   >.70 in/s Notes:
NA NA NA NA NA i
(Po) psig DitTer.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr FI-0619A 0-5000 12%
Qr NA NA NA Flowrate is set at reference value i
(Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instnr                     ' tion other than that listed, which meets the requirements of the Oh! Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instnr
: 4. Measurements are taken in a , .e pproximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible th.a bearing housmg.
' tion other than that listed, which meets the requirements of the Oh! Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a,
.e pproximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible th.a bearing housmg.
i i
i i
18 - 3                                                                                                                                     Rev.0                     j
18 - 3 Rev.0 j


f                                                                                                                                                                                                                               h Test Parameter Table - Pump 2-1205-P6-002 (Figure ISI-D-216)
f h
Instrunnentation Utilized                           Ref.       Acceptable                                                             Alert     Acties                                                   '
Test Parameter Table - Pump 2-1205-P6-002
Parasmeter       Test Free.       LD. No.f3)   Ranee         Ree. Acc. Value                           Ramme                                                                   Ranee     Range             Connasents                             ;
{
Speed (N)               NA             NA             NA           NA                             NA         NA                                                                   NA         NA               Constant speed dnver Inlet Pressure         Qtr             PI-8885       0-100       12%                             NA         NA                                                                   NA         NA               NA (Pi)                                             psig i
(Figure ISI-D-216)
Outlet Pressure           Qtr             PI-8887       0-400         12%                           NA         NA                                                                 NA           NA               NA (Po)                                             psig                                                                                                                                                                                                 -
Instrunnentation Utilized Ref.
Differ.
Acceptable Alert Acties Parasmeter Test Free.
Pressure         Qtr             NA(1)         NA           12%                         APr                                                                                                                                                       '
LD. No.f3)
                                                                                                          .90 - 1.10APr                                                     NA             <.90 er >l.10APr NA (AP)
Ranee Ree. Acc. Value Ramme Ranee Range Connasents Speed (N)
Flowrate           Qtr             F1-0619A       0-5000       12%                                       NA                                                               NA Qr                                                                                              NA               Flowrateis set at reference value (Q)                                               gpm t
NA NA NA NA NA NA NA NA Constant speed dnver Inlet Pressure Qtr PI-8885 0-100 12%
NA NA NA NA NA (Pi) psig i
f Outlet Pressure Qtr PI-8887 0-400 12%
NA NA NA NA NA (Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er >l.10APr NA (AP)
Flowrate Qtr F1-0619A 0-5000 12%
Qr NA NA NA Flowrateis set at reference value
(
(Q) gpm t
Vib.
Vib.
Amp.               Qtr             (2)           NA         15%                         Vr             s 2.5Vr                                                         > 2.5Vr - 6Vr     >6Vr or           NA (V)(4)                                                                                                                                                                                                                                               [
Amp.
or >.325 in/s   >.70 in/s                                                 !
Qtr (2)
Notes:
NA 15%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA
[
(V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differental pressure is calculated as, AP = Po - Pi
: 1. Differental pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                                       '
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of GPC, instrumentation other than that listed, which meets the reqmrements of the OM Code, may be utilized for measuring test parameters.                                                                                       l
: 3. At the discretion of GPC, instrumentation other than that listed, which meets the reqmrements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately r.r..dkwlar tc the rotating shan in two orthogonal directions on each accessible e . Wing housing and in the axial direction on each accesnNe thrust bearing housing.
l
18 -3                                                                                                               Rev.O
: 4. Measurements are taken in a plane approximately r.r..dkwlar tc the rotating shan in two orthogonal directions on each accessible
. Wing housing and in the axial e
direction on each accesnNe thrust bearing housing.
18 -3 Rev.O


Ag                                                                                                                                                         /
Ag
h NOTD THIS IS A SIMPLIFIED hN"                                                                                                                                                                                                                     ,                              FROM CONTAINMENT DIAGRAM USED TO DEPICT                         618A           0618                                                                                             FV                                                                                                 =               EMERGENCY SUMP A TEST CIRCUIT. REFER                                                                                                                               0610                                 2-1205-E6-001                 MCB TO THE P8.ID FOR DETAILS.                                 00                                               MCB                                                                                                      pg           pr               QMCB                                                 _                                                                                -
/
0618                                                                                           HV                                                           614/ 8886                                                               HV 606                                                                                                                                                        HS                                                                REFUELING VATER HV                       FT                                                                                           0606                                                           T 881I 809                                                                                                                                                                                                                      0620                                                                                  STORAGE TANK M               0618                                                                                                                                             (ogg 0612                                                     PI
h NOTD THIS IS A SIMPLIFIED hN" FROM CONTAINMENT DIAGRAM USED TO DEPICT 618A 0618 FV
                                                                                                                                                                                                                                                      ,      0601                                        P 2-1204-T4-001 SIS                           8' y y COLD LEG FO                                                    g-d U
=
li:         '$
EMERGENCY SUMP A TEST CIRCUIT. REFER 0610 2-1205-E6-001 MCB MCB TO THE P8.ID FOR DETAILS.
v              ]
00 pg pr QMCB 0618 HV 614/ 8886 HS HV REFUELING VATER HV FT 606 0606 T
                                                                                                                                                                                                                                                    '~
0620 881I M
LOOP                         8*                         Jl                                                                                                       M *xe-For                             @D                             ' '
0618 (ogg 0612 PI STORAGE TANK 809 2-1204-T4-001 0601 P
: 14. ,
SIS 8'
HV                                        l                                                                                                       N                                                             XI     TI           PI 804 M l' 06 8                                                                   FV                                                                                                                       M'           70 A CVCS CHARGING -                  -
y y d
0618                                         CVCS LETDOVN                                 2-1205-P6-001 PUMP SUCTION HEADER r
li:
N f                    ,C HEAT EXCHANGER 8
]
RESIDUAL HEAT REMOVAL PUMP 1
v COLD LEG U
J rg t                                                                           g HV 812 HV                                                                                  c'                                                                                     8'                     ,L C,             ,L C,                             RC 76                                                                                                                                                                                                                                           LO         1 M                                                                                                                                                                                                                                                                                 ,
LOOP 8*
I U
Jl FO
FV                                                  RHTkO27)                     (226)                             :      12'                                                                                                   24-RCS                 '
'~
g-M *xe-For
@D
: 14.,
l N
XI TI PI HV 804 M l' 06 8 FV M'
70 A CVCS CHARGING -
f 0618 CVCS LETDOVN 2-1205-P6-001 PUMP SUCTION r
HEAT EXCHANGER RESIDUAL HEAT 1
HV rg HEADER REMOVAL PUMP J
812 N
,C 8
t g
HV c'
8'
,L C,
,L C, RC 76 LO 1
M U
RHTkO27)
(226) 12' 24-I FV RCS FDT 0611 U
HOT LEG ' " '
HOT LEG ' " '
12 X8'                                 FDT 0611                                                                                                                                                                                                    U LOOP HV HIC QMCB M PI                                 QMCB                     1 '
12 X8' HV QMCB M PI QMCB 1 '
716                                                                                                                                                       o                           0615 8887                                                                                                                                                     '
HIC LOOP 716 o
HV 809 y           z HV 607 0607                                                           MCB M                                    0621 4*X8' y (020 0613 0602                               02   M
0615 8887 HV HV 607 M
                                                                                                                                                                                          -hG SIS                          I* B     I
0621 809 y z
::                      ll ll
0607 MCB 4*X8' (020 0613 y
: g. li;        '
0602 02 M
(    ]                                                    12 COLD LEG                                                                                                                                                                                  T --                                              -
ll ll
-hG li;
(
]
I*
I SIS B
g.
12*
12*
r,                          -RCS HOT LEG LOOP                                           FT                                                                                                         2"           2-1205-E6-002                                                                           ^                                                                                            LOOP 4 e-                                                                                                                                             RHR HEAT EXCH QMCB 0619 b
12
p;         k QMCB HV               0619
-RCS HOT LEG COLD LEG T --
                                                                  ' 0619 FY (022)                                         5015             5017       8885                   HV                                           b812 D                                                                                                                                                                                                               le 8811B 804                          [g9                                                                       0619                                             CVCS LETDOVN                                     2-1205-P6-002 SIS SAFETY INJECTION
r, LOOP FT 2" 2-1205-E6-002 LOOP 4
_        _J l
^
                                                                                    > 0 f                                                                                    HEAT EXCHANGER                                   RESIDUAL HEAT REMOVAL PUMP 1 F J  L (002 )
e-QMCB 0619 RHR HEAT EXCH k
M 812 HV 0619                                                                                                                                       s.                                                                               FROM CONTAINMENT PUMP SUCTION                                                                     FC                                                                                                                                                                                   EMERGENCY SUMP, 3 MCB                                           L-=-- FDT                                                                                                                                                                           12'                   "'                                ''
QMCB p;
MV. 94'E       SY   Dar g                           tKEERIPYED0                                                                                                         8PMt 3   APP 97   APf4.3 AP99 4   AP543 GEpulfRE 9     T*S-9     98iB   v5   332UF9 FER Pf?                                                                                                                                   I a       -e+-se   ca     sts urwts to Mvir or enassize                                                                                                                   -   JC
b HV 0619
*      *~"-"      *      "                "
' 0619 (022) 5015 5017 8885 HV b
C't%,,, ,'s,',7t '            ' ' " '                                                                                                      '
FY D
Southern Company Services. Inc. FOR Southern Nuclear Operofing Company 3     in-a-=   =           = =vi.     .c..o                                                                                                                       M5 UNIT 2                                 ""'                                                    " * ' v5 PUMP INSERVICE TESTING LOOP                                             ~ ,,,an                                           [.~m$,7t                         ,,n ,   .
le 8811B 812
FOR RESIDUAL HEAT REMOVAL PUMP
[g9 804 0619 CVCS LETDOVN 2-1205-P6-002 f
                                                                                                                                                                                                              ,                            2-1205-P6-001                           ,
l HEAT EXCHANGER RESIDUAL HEAT 1 F (002 )
N/A           N/A                           ISI-D- 266                                   10F 1 3
HV SIS SAFETY
_J REMOVAL PUMP J L M 812 INJECTION 0
FROM CONTAINMENT 0619 s.
PUMP SUCTION FC EMERGENCY SUMP, MCB L-=-- FDT 3
12' MV.
94'E SY Dar g tKEERIPYED0 8PMt 3 APP 97 APf4.3 AP99 4 AP543 GEpulfRE 9
T*S-9 98iB v5 332UF9 FER Pf?
I a
-e+-se ca sts urwts to Mvir or enassize
- JC
*~"-"
C't%,,,,'s,',7t Southern Company Services. Inc. FOR Southern Nuclear Operofing Company 3
in-a-=
=
= =vi.
.c..o M5 UNIT 2
" * ' v5 PUMP INSERVICE TESTING LOOP
~,,,an
[.~m$,7t
,,n,
FOR RESIDUAL HEAT REMOVAL PUMP 2-1205-P6-001 N/A N/A ISI-D-266 10F 1 3


(%                                                                                                                     ~\                                                                                           0 V                                                                                                                 (V                                                                                               V NOTE:    THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT                     I 618 nil"CM"                      FV
(%
                                                                                                                                                                    ,                                FROM CONTAINMENT 0618                                                                                                              :                EMERGENCY SUMP A TEST CIRCUIT REFER                                                                 0610                     2-1205-E6-001                 MCB TO THE P&ID FOR DETAILS.                                 00                   MCB                                                        pg           pr             QMCB                                           .                            .
~\\
0618                           HV                                               0614 8886               H                                       HV             REFUELING VATER HV                           FT                       606       0606                                       TE                             0620                                   8 811             STORAGE TANK 809 M                   0618                 \                                               gg9 0612
0 V
                                                                                                                                                                        ,        0601                           g    1 r SIS COLD LEG y
(V V
8" 8'
THIS IS A SIMPLIFIED nil"CM" FROM CONTAINMENT NOTE:
                                                  'i' d
DIAGRAM USED TO DEPICT I 618 0618 FV EMERGENCY SUMP A TEST CIRCUIT REFER 0610 2-1205-E6-001 MCB MCB TO THE P&ID FOR DETAILS.
                                                                            '[
00 pg pr QMCB 0618 HV 0614 8886 H
ro ll 2' I 8 G
HV REFUELING VATER HV FT 606 0606 TE 0620 8 811 STORAGE TANK 809 M 0618
U l4        '
\\
d            )
gg9 0612 0601 1 r g
h LOOP                                                                                                            FDT                           @                                N g4 06 804                                                     FY               r' (1223
SIS 8"
                                                                      't                                                                                                        8884 g,                 H CVCS CHARGING -             ''
l4 d
                            "'                                                      0618       CVCS LETDOVN                                   2-1205-P6-001                                                                       .
)
PUMP SUCTION                                                               Y                 HEAT EXCHANGER                                   RESIDUAL HEAT                                   r                                       HV r                                                                                                                                                          9 HEADER                                                             N                             8,                         p             REMOVAL PUMP                                 J L                                     812 C                                                                                                                                            M HV               HV        U                               /c                                                          j C,               LC, 76                                                                            8' RCbu F i "                   ,
h
U FV                                    RHT 2 @                       (h6)               Y           w      12'                                         24' 12*X8,                           0611 HD LEG                      HV                                                                                            QMCB M PI                               QMCB                     ' '
'i'
LOOP HV 8716 HV m
'[
TE 0615 8887 M                                                                                         7 0621 p309 M             r                     0607 4*X84           (020                                                       06 2                         02 I 8*   I M[
ll G
SIS         4                                 :.:                l     ll                                       G             y  :i:                                                     12-           o           RCS HOT LEG COLD LEU                                                   i i                                                T-                                     I         --                                            "'
y COLD LEG d
LOOP 4 LOOP                                           FT                                   2*   2-1205-E6-002                                     (010 )                           ' i^
ro U
e-   QMCB 0619
LOOP 8'
                                      /flC'\
2' I 8 FDT N
R[iR HEAT EXCH
g4 06 804
                                                                                                  "'                                                                TI p
't FY r'
8885
8884 H
(1223 g,
CVCS CHARGING -
0618 CVCS LETDOVN 2-1205-P6-001 PUMP SUCTION Y
r HEAT EXCHANGER RESIDUAL HEAT 9 r HV HEADER N
C 8,
p REMOVAL PUMP J L 812 M
HV U
/
8' j C, LC, RCbu F i "
HV c
76 RHT 2 @
(h6)
Y 12' U
w 24' FV 12*X8, 0611 QMCB M PI QMCB HD LEG HV m
0615 8887 M LOOP 8716 7
HV HV TE 0621 p309 M r
0607 4*X84 (020 06 2 02 I 8*
I M[
SIS 4
l ll G
:i:
RCS HOT LEG 12-o y
COLD LEU T-I i i LOOP 4 LOOP FT 2* 2-1205-E6-002 (010 )
' i^
e-QMCB 0619 R[iR HEAT EXCH
{
{
OMCB 5015                                             HV HV               0619.
OMCB p
FV 804                           LOO 0619                             0619        CVCS LETDOVN gr 8811B (12) f               HEAT EXCHANGER                                    2-1205-P6-002                               1 F       ^                             HV RESIDUAL HEAT                                   WM                   (002 )
/flC'\\
SIS SAFETY           _ "'
5015 8885 HV TI (12)
2                                                                                                                                                            j g g     812 INJECTION                                                   H l>           ll                                                             REMOVAL PUMP                           FRO 4 CONTAINMENT 619                                                         8                                                                                                                                         g PUMP SUCTION                                                             F:                                                                                                           EMERGENCY SUMP, j MCB                           W FDT                                                                                                       -
HV 0619.
12'               ' '      "
FV gr 8811B 804 LOO 0619 CVCS LETDOVN 0619 f
Ev. Mit       9T   Csa ?                           MsCar,pe                               APre s   aP992     APPR3   APPR 4   arpt3   Espets 9       9-S44   mis   WT     TEStK9 STR *TY                                                     I i     :-es-es cc     et. trwrts to arvn or es. esser                                   -JC
2-1205-P6-002 HEAT EXCHANGER 1 F (002 )
        ~        ""    "
HV
                              ","",t"L"a',71 ' " ' ' " "                                    ~
^
RESIDUAL HEAT WM 812 SIS SAFETY 2
j g g
INJECTION H l>
ll REMOVAL PUMP FRO 4 CONTAINMENT 619 8
g PUMP SUCTION F:
EMERGENCY SUMP, j
MCB W FDT 12' Ev.
Mit 9T Csa ?
MsCar,pe APre s aP992 APPR3 APPR 4 arpt3 Espets 9
9-S44 mis WT TEStK9 STR *TY I
i
:-es-es cc et.
trwrts to arvn or es. esser
-JC
","",t"L"a',71
~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company
Southern Company Services, Inc.FOR Southern Nuclear Operating Company
*                            ~~"
~
VOGTLE ELECTRI EgERATING PLANT E=8      "
~~"
_g'a y o
EgERATING PLANT
PUMP INSERVICE TESTING LOOP                                       ~ ,coua       SAE               .u r   .tv FOR RESIDUAL HEAT REMOVAL PUMP 2-1205-P6-002                                 N/A       N/A   ISI-D- 267       10F 1 3
_g'a y E=8 o
VOGTLE ELECTRI PUMP INSERVICE TESTING LOOP
~,coua SAE
.u r
.tv FOR RESIDUAL HEAT REMOVAL PUMP 2-1205-P6-002 N/A N/A ISI-D-267 10F 1 3


CS Pumps (2-1206-P6 001, & 002) f'~ System Function                 Containment spray limits the peak pressure in the containment to less than design pressure following a LOCA or a main steam line break inside containment. Trisodium phosphate is mixed with recirculated spray water in the containment sump region for pH control and to enhance absorption of the airborne fission product iodine and to     ,
CS Pumps (2-1206-P6 001, & 002) f'~
retain the iodine in the containment sump solution to limit calculated offsite doses to less than 10CFR100 limits.
System Function Containment spray limits the peak pressure in the containment to less than design pressure following a LOCA or a main steam line break inside containment. Trisodium phosphate is mixed with recirculated spray water in the containment sump region for pH control and to enhance absorption of the airborne fission product iodine and to retain the iodine in the containment sump solution to limit calculated offsite doses to less than 10CFR100 limits.
Quantity                         2 Type                             Horizontal, centrifugal Manufacturer /Model             Goulds Model 3415 Capacity                         2600 gpm Total Dynamic Head               450 ft.
Quantity 2
Driver Type                       Westinghouse electric motor, Frame 5010S g        Horsepower                 400 Speed                     1777 rpm Power Supply               4160V,60 Hz,3 phase Code Class                       2                                                           j Project Class                   212 I
Type Horizontal, centrifugal Manufacturer /Model Goulds Model 3415 Capacity 2600 gpm Total Dynamic Head 450 ft.
Outline Drawing                 2X6AD02-10 Instruction Book         ,,
Driver Type Westinghouse electric motor, Frame 5010S Horsepower 400 g
2X6AD02-18 Physical Location               Aux Bldg, Level D, Rooms R-D04 & R-DOS P&ID                             2X4DB131 Smveillance Procedure             14806-2 Pump Test Loop Diagrams           ISI-D-268 & ISI-D-269 Test Parameter Sheets             Page 19-2 & 19-3                                           I 19 - 1                             Rev.0             l
Speed 1777 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2
j Project Class 212 Outline Drawing 2X6AD02-10 Instruction Book 2X6AD02-18 Physical Location Aux Bldg, Level D, Rooms R-D04 & R-DOS P&ID 2X4DB131 Smveillance Procedure 14806-2 Pump Test Loop Diagrams ISI-D-268 & ISI-D-269 Test Parameter Sheets Page 19-2 & 19-3 19 - 1 Rev.0


o                                                                                                                   o                                                                                                                                                                     D Test Parameter Table - Pump 2-1206-P6-001 (Figure ISI-D-268)                                                                                                                                                                                                     ,
o o
instrumentation Utilized                         Ref.                                       Aeceptable                   Alert                                                 Action                                                                                   l Parameter         Test Frea.       I.D. No.(3)   Range         Rea. Acc.               Value                                       Range                       Range                                                 Range                                                 Comments                           -
D i
r Speed                                                                                                                                                                                                                                                                                                             '
Test Parameter Table - Pump 2-1206-P6-001 (Figure ISI-D-268) instrumentation Utilized Ref.
(N)               NA               NA             NA           NA                       NA                                         NA                           NA                                                   NA                                                   Constant speed driver Inlet Pressure           Qtr             PI-0972       0-100         12%                       NA                                         NA                           NA                                                   NA                                                   NA                                 i psig                                                                                                                                                                                                                                                            l (Pi)                                                                                                                                                                                                                                                                                                               !
Aeceptable Alert Action l
Parameter Test Frea.
I.D. No.(3)
Range Rea. Acc.
Value Range Range Range Comments r
Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-0972 0-100 12%
NA NA NA NA NA i
(Pi) psig l
(
(
Outlet                                                                                                                                                                                                                                                                                                             i Pressure           Qtr             PI-0974       0-300         i2%                       NA                                         NA                           NA                                                   NA                                                     NA                   ,
Outlet i
(Po)                                               psig i
(
Differ.                                                                                                                                                                                                                                                                                                           ,
Pressure Qtr PI-0974 0-300 i2%
Pressure           Qtr             NA(1)         NA             i2%                       APr                                         .90 - 1.10APr               NA                                                   <.90 or >l.10APr NA                                                                       ,
NA NA NA NA NA (Po) psig i
(AP) r Flowrate           Qtr             F1-0929       0-400         12%                       Qr                                         NA                           NA                                                   NA                                                     Flowrate is set at reference value j (Q)                                               gpm Vib.
Differ.
Amp.               Qtr             (2)           NA             i5%                       Vr                                         s 2.5Vr                     > 2.5Vr - 6Vr                                         >6Vr or -                                             NA                                 !
Pressure Qtr NA(1)
(V)(4)                                                                                                                                                             or >.325 in/s                                       >.70 in/s                                                                                 ,
NA i2%
s Notes:                                                                                                                                                                                                                                                                                                             l
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP) r Flowrate Qtr F1-0929 0-400 12%
Qr NA NA NA Flowrate is set at reference value j
(Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or -
NA (V)(4) or >.325 in/s
>.70 in/s
{
s Notes:
(
l
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instmments are utilized.
: 2. Portable vibration instmments are utilized.
Line 2,862: Line 5,866:
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
I i
I i
19 - 2                                                                                                                                                                               Rev.0
19 - 2 Rev.0
                                                        - -        . . - _    . _ _ _ . ~     -________._----_.-__--__..__-_--____n_  -                                      _ _ _ - - - - _ _ . . - _ . - _ _ -_ - - - _ _ . . _ _ - - _ - - _ _ _ - - _ - - _ . , . - - -                              . -,
. ~
n


O                                                                                 O                                                                                                                                                           l Test Parameter Table - Pump 2-1206-P6-002 (Figure ISI-D-269)
O O
Instrumentation Utilized         Ref.           Acceptable           Alert                   Action Parameter         Test Freq.           1.D. No.(3)   Range         Req. Acc. Value           Range               Range                   Range                         Comments Speed (N)               NA                   NA           NA           NA       NA             NA                   NA                     NA                           Constant speed driver Inlet Pressure           Qtr                   PI-0973       0-100         12%       NA             NA                   NA                     NA                             NA (Pi)                                                   psig                                                                                                                                                                                                         ,
l Test Parameter Table - Pump 2-1206-P6-002 (Figure ISI-D-269)
Outlet Pressure           Qtr                   PI-0975       0-300       12%       NA             NA                   NA                     NA                             NA                                                                           i (Po)                                                   psig Differ.
Instrumentation Utilized Ref.
Pressure           Qtr                   NA(1)         NA           12%       APr           .90 - l .10APr       NA                     <.90 er >l.10APr NA (AP)
Acceptable Alert Action Parameter Test Freq.
Flowrate           Qtr                   F1-0929       0-400       12%       Qr             NA                   NA                     NA                             Flowrate is set at reference value (Q)                                                   gpm                                                                                                                                                                                                           ,
1.D. No.(3)
Vib.                                                                                                                                                                                                                                                                 l A m p.             Qtr                   (2)           NA           i5%       Vr             s 2.5Vr               > 2.5Vr - 6Vr         >6Vr or                       NA                                                                                         I (V)(4)                                                                                                             or >.325 in/s         >.70 in/s                                                                                                                 l t
Range Req. Acc. Value Range Range Range Comments Speed (N)
Notes:
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-0973 0-100 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-0975 0-300 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - l.10APr NA
<.90 er >l.10APr NA (AP)
Flowrate Qtr F1-0929 0-400 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
l A m p.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA I
(V)(4) or >.325 in/s
>.70 in/s l
t Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                                                         i direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial i
direction on each accessible thrust bearing housing.
8 k
8 k
19-3                                                                                                                                                 Rev.0 t
19-3 Rev.0 t
i
i m
                                . _ . _                                          _ . . _ _ . _        . _ _ _              .         m_ . . _      . _ . _ . _ . . _ _ . _ . _ _ . _ _ . _ _ . _ _ . _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _              __
 
p
,/-
N Q -]
0 NOTE: THIS IS A SIMPLIFIED
,L C, p,
DIAGRAM USED TO DEPICT r,
A TEST CIRCUIT. REFER M
TO THE P8.ID FOR DETAILS.
HV 003 d 9003 QMCB QMCB QMCB
(">
9001 M
FROM CONTAINMENT HV TI PI 1094 1 9001A 0938 0974 PI 12' EMERGENCY SUMP FI 929 QM 0972 12,X10, TD Cny T^.!NMENT - yq I
12*X10*
U 12' SPRAY 8,
F-c n
o--
a e 5010 2-1206-P6-001 d
C
_y
~
_a CONTAINMENT SPRAY g
OMCB CONTAINMEN 5012 TRAIN
'A' SPRAY EDUCTOR s
M 9017A 2-1206-J6-001
_ C o
P 1093 10' 90 A_
8, 3
REFUELING VATER
=
3' PCP STORAGE TANK oprG 2-1204-T4-001 8JL C E,
v CONTAINMENT
-k M
HV QMCB SPRAY EDUCTOR c>
r, 10 9017B 2-1206-J6-002 U.52)
MCB 9001B MCB HV H
M 9017B n
9001B TI a
s 1094 M
0939 J n
g 09 3 HV
,r--
9003 TD 8'
S 9003 m
i CONTAINMENT 7'
g XI O
SPRAY 2-1206-P6-002 l
PI 5011 FROM CONTAINMENT M
CONTAINMENT SPRAY 2
12' 7'
EMERGENCY SUMP 0975 D-PUMP - TRAIN
'B' M
e-
@rh G
W B08 v1 ISSE rtR PST I
L__i-as-es c4 ats urnarts in arvas y eneessa
- JC l
iC y",
C Z'((w'.'"m,,,..,,, bk Southern Company Services, Inc.FOR Southern Nuclear Operating Company c= sri n.= ro to==
r-e-ev.
ac aci
.c a
w V0GTLE ELECTRI EgERATING PLANT 8[8 = * "
8
"'c SCALE em CIDffpaKB (Be SM.ET PUMP INSERVICE TESTING LOOP ua 1,
a FOR CDNTAINMENT SPRAY PUMP l
2-1206-P6-001 N/A N/A ISI-D-268 10F 1 4


p                                                                                    ,/-
NOTE: THIS IS A SIMPLIFIED
N                                                                                    Q -]                                                      -
,LC 2"
0 NOTE: THIS IS A SIMPLIFIED                                                                             ,L C,      p, DIAGRAM USED TO DEPICT                                                                               r, M
DIAGRAM USED TO DEPICT 2
A TEST CIRCUIT. REFER TO THE P8.ID FOR DETAILS.
r, A TEST CIRCUIT. REFER (006)
                                                                                                        @                                              HV 003 QMCB                                                                                                                         d 9003 QMCB                               QMCB          (">
QMCB TO JHE P8.ID FOR DETAILS.
9001 HV           TI       PI M                                                                FROM CONTAINMENT 1094                                         12'                     EMERGENCY SUMP         FI 1 9001A            0938 0974                                                            PI                                                          929 TD                                                                            .                        0972                   12,X10,                                            -
j; 4 9003A QMCB QMCB U
Cny T^.!NMENT -QM        yq                                                      I 12*X10*     12'               U 8,
9001A M
SPRAY                                                                                  F-c                                                                                    o--
F GM CONTAINMENT HV TI PI 1094 7'
n a    e ~        5010                 2-1206-P6-001           d                C                                                  _y
~
_a                                  CONTAINMENT SPRAY                           g              OMCB CONTAINMEN                                             TRAIN 'A' 5012 SPRAY EDUCTOR               s                                                                     M   9017A 2-1206-J6-001             _ C o  P    1093                                                     10' 90   A_                        .
m 9001A 0938 0974 PI 12' EMERGENCY SUMP FI __
8,3                                                                            REFUELING VATER         =
0929 TO 0972 12*X10' CONTAINMENT - "'-
3' PCP      STORAGE TANK oprG                                                          E,                      2-1204-T4-001 8JL C v
1 12*X10*
QMCB CONTAINMENT SPRAY EDUCTOR
12' SPRAY 8'
                                                                      -kc>                                          M r,
}--C o
HV                                                       '
5010 2-1206-P6-001 0
                                                                        "                                                              10    9017B 2-1206-J6-002                                                           U.52)                                  MCB 9001B HV                                                       MCB                                          M n                      H                                                          9017B 9001B         TI      a     s                      1094 M                 0939 J                                                                                    n g                                     09 3                                $      HV       ,r-- 9003 TD                 m 7'
W__g
8'                                        i              ,                                        S   9003     g CONTAINMENT                                                                           O SPRAY                                                           XI 5011                      2-1206-P6-002                      l                          FROM CONTAINMENT PI 0975                   M                CONTAINMENT SPRAY PUMP - TRAIN       'B' 12'             7' 2
~
EMERGENCY SUMP D-                         M            e-
_s CONTAINMENT SPRAY y
                                                                                                      @rh G    W      B08    v1      ISSE rtR PST                                        I                                                                   .
QMCB CONTAINMEN 5012 TRAIN *A*
L__i-as-es    c4    ats    urnarts in arvas y eneessa                      - JC l    iC      y",            C Z'((w'.'"m ,,, . .,, ,                        bk                                Southern Company Services, Inc.FOR Southern Nuclear Operating Company c= sri n .= ro to ==
SPRAY EDUCTOR s
r-e-          ac                                                      w                                                                                          _""
M 9017A 2-1206-J6-001,/, O u
.            ev.                      .c a aci                                                                              V0GTLE ELECTRI                        8[8 = * "            8        "'c EgERATING PLANT_
1093 10' 90 A.
SCALE    em        CIDffpaKB (Be SM.ET PUMP INSERVICE TESTING LOOP                        ua                              1, a FOR CDNTAINMENT SPRAY PUMP l                                                                                                            2-1206-P6-001                  N/A        N/A ISI-D- 268              10F 1 4
S 3'
3,
* REFUELING VATER QPCP STORAGE TANK PE T
uL a 2'
O98 2-1204 -T4-001 v
Z CONTAINMENT
~[CD M
HV QMCB SPRAY EDUCTOR o
2-1206-J6-002 152 go.
9017B MCB 9001B 3
QMCB HV M
9017B r
9001B Tl a
~
1094 M
0939 2
m g
HV r-- 9003 09 3 TD 8'
S 9003 I
I, g
CONTAINMENT 7'
Q 0
SPRAY
~~
h011M
, CONTAINMENT SPRAY 12' r' ' FROM CONTAINMENT PI EMERGENCY SUMP 0975
-8 PUMP - TRAIN
'B' V5013 M
a' I
=
dI5h aE v.
3.rt av oerg m3casPYuss meeJ mppea appeJ arets appas ajanlas mas vs nsx rm m I
t-ES-GB CA.
I,LB tr3.TED TU EvJS IF 22493t3
._)2
=
e-w itv su arvrucs v=ves - essest a em
-LMs Southern Company Services, Inc.FOR Southern Nuclear Operating Company JJ n-u m vs


NOTE: THIS IS A SIMPLIFIED                                                                                                ,LC DIAGRAM USED TO DEPICT                                                                                                r, 2                                2"                                                              -      -
==
A TEST CIRCUIT. REFER                                                                                              (006)                                                    QMCB j;
miovra spear ansmvt = a v=vts er,.
TO JHE P8.ID FOR DETAILS.
o c n.,m Ye ro
QMCB                                                                          QMCB                                                                                          4 U
-m ir,.
9003A 9001A HV          TI        PI M                                                                                              ~    m      F GM CONTAINMENT 1094                                                                                  12'          7' EMERGENCY SUMP        FI __
,v.
9001A          0938 0974                                                                                                        PI                                                          0929      -
m
TO                                                                                  -                                                              0972                          12*X10' CONTAINMENT - "'-                                                                    1 12*X10* 12' SPRAY                              8'                                                            }--C                                                                                                                          -
.c
o              5010                          2-1206-P6-001                                                  0                                                            W
.c 3
                                                                        ~                                                                                                                                                                  __g
og5 VOGTLE ELECTRI EgERATINGPLANT nsreca n
_s                                      CONTAINMENT SPRAY                                                                    y            QMCB CONTAINMEN                                                                                                                                                                    ,
.c scaz a=rous a. s=ri PUMP INSERVICE TESTING LOOP
5012                TRAIN *A*
,.aa.
SPRAY EDUCTOR              s                                                                                                                  M    9017A 2-1206-J6-001 ,/, O u      1093                                                                                                  10'      90  A.                        .
a
S                                                                                                                          REFUELING VATER 3'    3,
.tr e erv.
* T    QPCP      STORAGE TANK PE                                                                                                                              2-1204 -T4-001 uL a v
1 FOR CONTAINMENT SPRAY PUMP 2-1206-P6-002 N/A N/A ISI-D-269 1Wl 4
2'      O98 Z
QMCB CONTAINMENT SPRAY EDUCTOR
                                                                            ~[CD o
M                              HV 9017B
                                                                              "                                                                                                          go.
2-1206-J6-002                                                                                                      152                                    MCB 9001B 3                      QMCB HV                      r                                                                                                                          M    9017B 9001B        Tl      a    ~                      1094 M                                                                                                                                                          m 0939      2 g                                              09 3                                                                  $      HV      r-- 9003 TD                  &
7' 8'                                        I I,
S    9003    g CONTAINMENT SPRAY                                                              Q                  0
                                                                                                              -        ~~
PI 0975              h011M            -8
                                                                                                , CONTAINMENT SPRAY PUMP - TRAIN                                  'B' 12' r'
                                                                                                                                                                                                              ' FROM CONTAINMENT EMERGENCY SUMP I
V5013                                  M                                        a'                                                                            =
aE v. 3.rt      av    oerg dI5h m3casPYuss                  meeJ    mppea    appeJ    arets  appas                  ajanlas
.        , - -    mas    vs      nsx rm m I        t-ES-GB  CA. I,LB tr3.TED TU EvJS IF 22493t3                      _  ._)2
=        e-w      itv    su      arvrucs v=ves - essest a em                        JJ n-u m vs        ==      miovra spear ansmvt = a v=vts er,.             -LMs                                                        Southern Company Services, Inc.FOR Southern Nuclear Operating Company o c n .,m Ye ro       -m
.        ir,.     ,v. m         .c         .c 3                               og5                                                       VOGTLE ELECTRI                                               nsreca n                   .c EgERATINGPLANT scaz               a=rous a. s=ri PUMP INSERVICE TESTING LOOP                                   ,.aa.             a     .tr e erv. 1 FOR CONTAINMENT SPRAY PUMP 2-1206-P6-002                 N/A       N/A ISI-D- 269       1Wl     4


      . __. ___          .    . - _ -  .    .- . . _ _ ~_ . _ _                   . . _ _ _ _ _ _ ~ . _ . _ _ . _ . .
.-.. _ _ ~_. _ _
i CVCS Pumps 3
.. _ _ _ _ _ _ ~. _. _ _. _..
CENTRIFUGAL CHARGINGPUMPS                                                         '
i CVCS Pumps CENTRIFUGAL CHARGINGPUMPS 3
(2-1208-P6-002, & 003)
(2-1208-P6-002, & 003)
{
{
;              System Function             -
System Function The primary functions of the CVCS are to:
The primary functions of the CVCS are to:                                 I Regulate reactor coolant chemistry for reactivity and corrosion control I
I Regulate reactor coolant chemistry for reactivity and corrosion control I
Maintains the water level in the pressurizer of the RCS Maintains seal-water injection flow to the reactor coolant pump Provide a means offilling, draining and pressure testing 4                                                        the RCS Provide injection flow to the RCS following actuation j                                                       ofSIS i
Maintains the water level in the pressurizer of the RCS Maintains seal-water injection flow to the reactor coolant pump Provide a means offilling, draining and pressure testing the RCS 4
;            Quantity                           2
Provide injection flow to the RCS following actuation j
!            Type.
ofSIS i
Quantity 2
Type.
Horizontal, centrifugal,11 stage
Horizontal, centrifugal,11 stage
)             Manufacturer /Model                 Pacific, U 2-1/2 in., RL i
)
j             Capacity                           150 gpm TotalDynamic Head                   5800 ft.
Manufacturer /Model Pacific, U 2-1/2 in., RL i
C\
j Capacity 150 gpm TotalDynamic Head 5800 ft.
(/       Driver
C\\
,                    Type                         Westinghouse electric motor 4
(/
Horsepower                   600                                                                       !
Driver Type Westinghouse electric motor 4
3                    Speed                       1800 rpm j                   Power Supply                 4160V,60 Hz,3 phase J
Horsepower 600 3
J.   ,
Speed 1800 rpm j
Code Class                           2                                                                         1 Project Class                       212                                                                         l Outline Drawing                     2X6AH02-100 Instruction Book                   2X6AH02-85 Physical Location                   Aux Bldg, Level C, Rooms R-C16 & R-C17 P&ID                               2X4DB116-2 Surveillance Procedure               14808-2 Pump Test Loop Diagrams             ISI-D-270 & ISI-D-271 O         Test Parameter Sheets               Page 20-2 & 20-3 20-1                                               Rev.O
Power Supply 4160V,60 Hz,3 phase J
J.
Code Class 2
1 Project Class 212 l
Outline Drawing 2X6AH02-100 Instruction Book 2X6AH02-85 Physical Location Aux Bldg, Level C, Rooms R-C16 & R-C17 P&ID 2X4DB116-2 Surveillance Procedure 14808-2 Pump Test Loop Diagrams ISI-D-270 & ISI-D-271 O
Test Parameter Sheets Page 20-2 & 20-3 20-1 Rev.O


w                                                                               3                                                                                                                                   s         '
w 3
                                                                                                                                                                                                                                  )
s
)
Test Parameter Table - Pump 2-1208-P6-002 (Figure ISI-D-270)
Test Parameter Table - Pump 2-1208-P6-002 (Figure ISI-D-270)
InstInnentation Utilized                 Ref.     Acceptable                                                   Alert           Action Parameter         Test Freq.       I.D. No.0)     Range         Req. Ace.         Value     Range                                                       Range           Range                         Comments Speed (N)               NA               NA             NA           NA                 NA       NA                                                           NA             NA                           Constant speed driver Inlet Pressure           Qtr             PI-8891       0-100         12%               NA       NA                                                           NA             NA                           NA (Pi)                                               psig Outlet                                                                                                                                                                                                                                     ,
InstInnentation Utilized Ref.
Pressure           Qtr             PI-8472       0-4000       12%               NA       NA                                                         NA               NA                           NA                 i (Po)                                               psig                                                                                                                                                                                     i Differ.
Acceptable Alert Action Parameter Test Freq.
Pressure           Qtr             NA(1)         NA           12%                 APr       % - 1.10APr                                               NA               <.90 or >l.10APr NA (AP)
I.D. No.0)
Flowrate           Qtr             F1-10120     0-80         12%                 Qr       NA                                                         NA               NA                             Flowrate is set at reference value (Q)                                               gpm Vib.
Range Req. Ace.
A m p.             Qtr             (2)           NA           15%                 Vr       s 2.5Vr                                                   > 2.5Vr - 6Vr   >6Vr or                       NA (V)(4)                                                                                                                                                   or >.325 in/s   >.70 in/s                                                         >
Value Range Range Range Comments Speed (N)
Notes:
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-8891 0-100 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8472 0-4000 12%
NA NA NA NA NA i
(Po) psig i
Differ.
Pressure Qtr NA(1)
NA 12%
APr
% - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr F1-10120 0-80 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
A m p.
Qtr (2)
NA 15%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than sat listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than sat listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
20-2                                                                                                                 Rev.0
20-2 Rev.0
[


                                                                                                                                                                                                                                                                                                  )                               !
)
s Test Parameter Table - Pump 2-1208-P6-003 (Figure ISI-D-271)                                                                                                                                           ,
s Test Parameter Table - Pump 2-1208-P6-003 (Figure ISI-D-271)
Instrumentation Utilized                                                                     Ref.       Acceptable             Alert                       Action                                                                                         !
Instrumentation Utilized Ref.
Parameter                 Test Frea.                 I.D. NoJ3)               Range         Rea. Acc.                                                   Yalue     Range                   Range                       Range                         Comments                                                       j Speed (N)                       NA                         NA                       NA           NA                                                           NA       NA                       NA                           NA                             Constant speed driver i
Acceptable Alert Action Parameter Test Frea.
Inlet Pressure                   Qtr                         PI-8892                   0-100       12%                                                         NA       NA                       NA                           NA                             NA                                                             *
I.D. NoJ3)
(Pi)                                                                             psig Outlet Pressure                   Qtr                         PI-8473                   0-4000       12%                                                         NA       NA                       NA                           NA                             NA                         i                                   ,
Range Rea. Acc.
t j       (Po)                                                                             psig Differ.
Yalue Range Range Range Comments j
Pressure                   Qtr                         NA(1)                   NA           12%                                                           APr       .90 - 1.10APr           NA                           <.90 er > l.10APr NA t
Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver i
Inlet Pressure Qtr PI-8892 0-100 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8473 0-4000 12%
NA NA NA NA NA i
t j
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 er > l.10APr NA t
(AP)
(AP)
Flowrate                   Qtr                         F1-10121                 0-80         12%                                                           Qr       NA                       NA                           NA                             Flowrate is set at reference value                             ;
Flowrate Qtr F1-10121 0-80 12%
(Q)                                                                             gpm i
Qr NA NA NA Flowrate is set at reference value (Q) gpm i
Vib.
Vib.
Amp.                       Qtr                         (2)                     NA           15%                                                           Vr       s 2.5Vr                 > 2.5Vr - 6Vr               >6Vr or                       NA                                                             :
Amp.
(V)(4)                                                                                                                                                                                       or >.325 in/s               >.70 in/s                                                                                     .
Qtr (2)
NA 15%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s L
l i
l i
Notes:                                                                                                                                                                                                                                                                                                                   ;
Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instnamentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instnamentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.                                                                                                                                                                                                                                                                 -[
F
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
-[
[
[
20-3                                                                                                   Rev.0
20-3 Rev.0 1
[
[
                                                                                                                                                                                        . - - - - - _ - _ . - - _ _ - _ _ . _ _ _ . _ - - - _ _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ - _ _ - _ _ , - _ _ - _ - - _ _ _ _ - _ _ . _ _ _ -l
. - - - - - _ - _. - - _ _ - _ _. _ _ _. _ - - - _ _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ - _ _ - _ _, - _ _ - _ - - _ _ _ _ - _ _. _ _ _ -l
 
.O O)-
i b
V 4 X3*
SEAL VATER LC e
3' 329B N3* ][i l
120 _
3*
3-RVST 2'
h 3*
GU l
8110 l
3, VOLUME REACTOR U
3*X2' l
. ONgQAg OMCB 2-1208-P6-001 l'
COOLANT RHT'
/IiSN POSITIVE DISPLACEMENT L
L j
CHARGING PUMP RHT 4-M SEALS D
ll M FD g3 CVCS FV G3D GED 10120
-3*X2-PS 12C 112B REGENERATIVE gN II MCB FT QMC FI 508 if RHT i
EXCHANGER
/TiSh0MCB 8 2 273 M
pg g
E 0187 g
aMr 8891
=
CVCS LUU
?
/'
i' O' 4 E
h
, 6*
REACTOR O
ggi
'2-1208-P6-002 '
013 CDOLANT PUMP RHT g
X CENTRIFUGAL H
SEALS MCB F
5018 CHARGING PUMP 471 10th!
3*X2 QMCB TRAIN *A*
a LRHT QMCB NOTE: THIS IS A H
HS 12D SIMPLIFIED DIAGRAM 4g 3*
PI b
USED TO DEPICT A TEST HV 8473 74 PI MCB RH pg CIRCUIT. REFER TO THE 485 q
018 8 8 *'
8892 A
PLI.D. FOR DETAILS.
A if E
I 6-8'X6*
GED S
'2-1208-P6-003 k (
) '48)
RHT e508 xI H
V Ugp 47l l 2E HV HV TRAIN *B*
HSN
(
801A 801B 508 4 71 FROM J LRHT MCB REFUELING TD RCS COLD LEGS RVST VATER STORAGE TANK 8E'A MTE BY Der *B KSCAFTEss arrGJ srPW2 apptJ APPE4 aPPt.S EgaMut3 P
N ESS VS IISUE FtEt PST
' I s-es-se ca.


                  .O                                                                                                                                                                                                                                                                                                                                                                                                                                i b                                                                                                                                                                                                                                                                                                                              V                                                                                                O)-
==
4 X3*                                                      SEAL VATER                                                                                                                                                                                                                                                                                          LC          e      3' l                                                                                        120    329B N3* ][i                                                                                                                                                                                                                                                                                                                                                                                                              _                                          3*
tenarts u irva y ev4emm-e
3-                                                                                                                                                                                                                                                                                                  RVST                      2' h    _.
- JC Ie E
                                  -                      3*                                                      GU                                                                                                                                  l                            8110 l                                        3,                                              VOLUME U
~E"t>YE caers i asern es oma a,
ONgQAg                    $
Ei Southern Company Services, Inc.FOR Southern Nuclear Operating Company vs n
REACTOR 3*X2'                                                                                                                                                                                                                                                          l
C E
                      '                                                                                                                                                                                                                                                                                                                                                  OMCB                2-1208-P6-001                                                        L  l' COOLANT                          RHT'                                                                                                                                                                                                                                                                                                                      j    /IiSN              POSITIVE DISPLACEMENT                                                      L CHARGING PUMP SEALS                                                                                                                                                                                                                                                                                                                                                                                                                                RHT    4-                M D                                                                                                                          ll                                                                                                      M FD                                                                                                                                                                              g3 CVCS                          @                                                                                                                                                                        FV                                                  G3D GED 10120                                                                                                    PS                                            12C                    112B II                                                                                                                                              -3*X2-                                                                                          MCB REGENERATIVE                                                                  gN                                                                          FT                                                                                                          QMC                                                                FI                                  508                                          if    RHT        i EXCHANGER                    /TiSh0MCB                                                                                                                                                                                                                                                                                                                            8 2              273        pg    M g                            E                                            8891 0187                g              aMr                  =
My ir w, " '" cams, " " " " " " " " "
CVCS                                                                                                                                      LUU                                                                                                                                                              ?                                                    i'
N VDGTLE ELECTRIC GENERATING PLANT 8t=8 s
                                                                                                                                                                                                                                                                                                                                        /'                                                                                    O' 4                  E REACTOR CDOLANT PUMP                                                                                                                                                                                                                                                                                                      RHT O          ggi
,"*,'88"*"
                                                                                                                                                                                                                                                                                                                                                                                                    ,        , 6*
                                                                                                                                                                                                                                                                                                                                                                                                    '2-1208-P6-002 '                                          013 h    '
SEALS                                                                                                                                                                                  MCB                                                                                                                                ' g                                                X              CENTRIFUGAL                  H F                                                  CHARGING PUMP                  471 QMCB a  LRHT 10th!                  3*X2 5018            QMCB        TRAIN *A*
NOTE: THIS IS A                                                                                                                                                                                                                                                                                                      H 3*
HS                $    -
12D SIMPLIFIED DIAGRAM                                                                                                                                                                                                                                                                                                4g                                                    PI                                                                  b                    RH USED TO DEPICT A TEST                                                                                                                                                                                                                                                        HV                                                                                      8473                74            pg      PI              MCB CIRCUIT. REFER TO THE                                                                                                                                                                                                                                                    485                                                                            q                                                    018 8
                                                                                                                                                                                                                                                                                                                                                            ,                                            8892                                          A 8 *'
PLI.D. FOR DETAILS.                                                                                                                                                                                                                                                                                                                                      E A                            if                      I  '
                                                                                                                                                                                                                                                                                                                                                                                                  ,                ,      6-          8'X6*          GED                  ,
S                          '2-1208-P6-003 HV k(                                                                                                            ) '48)
RHT                                          e508                  xI                      Ugp TRAIN *B*
H 47l V
l 2E HV                                                                                                                                                                                    HSN                                        (
801A                                                                                                                                                      801B                                                                                              '
J LRHT 508                                                        4 71                              FROM MCB              REFUELING TD RCS COLD LEGS                                                                                                                                                                                                                                                !,                  RVST VATER STORAGE TANK 8E'A  MTE      BY      Der *B                                                                                        KSCAFTEss                                                                                                                                                            arrGJ                        srPW2  apptJ APPE4  aPPt.S  EgaMut3 P      N                VS ESS              IISUE FtEt PST                                                                                                                                                                                                                                                      ' I s-es-se ca.      ==    tenarts u irva y ev4emm-e                                                                                                                                                                                                                                 -         JC Ie     vs        E     ~E"t>YE n                              caers i asern es oma a ,                                                                                                                                                                                                 Ei                                                             Southern Company Services, Inc.FOR Southern Nuclear Operating Company s      C E             My       "
ir w , " '" cams, " " " " " " " " "                                                                                                                                                                                                                     N                                                                 VDGTLE ELECTRIC GENERATING PLANT                     8t=8       "
UNIT 2                          "**
                                                                                                                                                                                                                                                                                                                                                                                                                                            ,"*,'88"*"
y***
y***
PUMP INSERVICE TESTING LOOP                                         ana           m.v               .o,   av
UNIT 2 PUMP INSERVICE TESTING LOOP ana m.v
                                                                                                                                                                                                                                                                                                                                                                      "                ^     ^
.o, av
2       08-P -002                       N/A           N/A         ISI-D- 270         1 IF 1 5
^
^
2 08-P -002 N/A N/A ISI-D-270 1 IF 1 5


Q)                                                                                             %)                                                                                                                                                                                                 J 4 X3'         SEAL VATER                                                                                                                                                                     LC                                                         ,
Q)
32 B h ,1 [i L                             12             3
%)
                                                  )                                                                                                                                                                                                                                         =
J 4 X3' SEAL VATER LC 32 B h,1 [i L 12 3 3'
3' 3'                                                  H       RVST                             2' H                 n        3'     (IDE)d                   8110 7'
)
l                                                                          3                                                                                                   1     VOLUME                     v   i CVCS                   r REACTOR          c    6'           3'X2' e                        s                  l                                                                 MCB                                         2-1208-P6-001
=
                                                                                                                                                                                                                                                                                                        -1      - -
3' H
fyt%^ #T CDOLANT                       RHT                     rr                                                                                                     POSITIVE DISPLACEMENT PUMP                                               0121                                                                                                                                                                                                                                                                         t 111                                               CHARGING PUMP SEALS ggg                                                                                                                                                                                                 RHT     4-                 Il2B D                   ll             g FO                                                                                                                                                                                                                         '
RVST 2'
CVCS                     @                          FV     (I3D (IEH) 10 20                                                                     PS                                                                                                                                      112C                    ll2B
H 3'
                                                                                                                                              -3'X2' REGE       TIVE                       gg                 121 QMC                               FI                                              508                                                                                                                                   I RHT_g HS                                                                                                                                     MCB EXCHANGER                 /Tih 0MCB                                             H h485                                                           8 2                 273                                                         pg                                     PI                                      OMC                      y
(IDE)d n
                                                                                                                    !                                  Ie 8891 0187                ggp -a M,                            =
8110 l
CVCS                                       LOD                       p   ,
3 1
                                                                                              /
VOLUME 7'
6,            8'X 4'           ,
v i
(Ig2)               p SEALS                                           QMCB                         '
CVCS 6'
C                                        G       P QMCB             '  6RHT 101 1                               3'X2 5018    " OMCB                                                                                                                        g3             b            LV NOTE: THIS IS A                                                                H          ,                                                                                                                                                                                                                5 8-         112D SIMPLIFIED DIAGRAM                                                           4                                                                     PI                                                                                                                                     4 73                                       BS 274                                                                                                            PI            MCB                                  RHT USED TO DEPICT A TEST                                               HV                                                                           8473                                                                                                                   pg CIRCUIT. REFER TO THE                                               485                                                                                                                                                                                     8892               018 8 P8,I.D. FOR DETAILS.                                                                                                         h                                                I a                     i O
3'X2' l
4'l                       O 1                                                                                               6         8'X6'           M
-1 r
                                                                                                                                              /P                                                                                 2-1208-P6-003 g i  P L
fyt%^ #T REACTOR MCB 2-1208-P6-001 c
1 J
e s
g             RHT                                                             508     [XI                                                                                 CENTRIFUGAL CHARGING PUMP H
CDOLANT RHT rr POSITIVE DISPLACEMENT t
4 71 LV 112E 5019 HV                       HV                                                                                                                                                                                                                           HS 801A                   801B                           1 2
PUMP 0121 111 CHARGING PUMP ggg RHT 4-Il2B SEALS D
LRHT 508                                                                                                                                             471                             FROM           !
ll g FO 112C ll2B CVCS FV (I3D (IEH) 10 20
                                                                                                                      ,                                                                                                                                                                              MCB               REFUELING TO RCS COLD LEGS                                                           , ,                              RVST VATER STORAGE TANK av.   ==              o=,                      .nc.m                    -u    -,    -2      -            -as                        =:
. -3'X2' PS REGE TIVE gg 121 QMC 508 I
9      WW      Elit    V5  IISLEB FGt PTT                                  *I s-as-se ca. sto irmus in arv.ns a r:4eam-e                    -  ._C
RHT_g HS FI MCB EXCHANGER
                          ~
/Tih H
iN      v~s .S      =ur."r>7 ~- anet asus Ps esem a e            55.                                          Southern Company Services, Inc.FOR Southern Nuclear Operating Company 3      EE E          E    .Yr""c*"*""""**""""
OMC y
N                                            V0GTLE ELECTRIC GENERATING PLANT K58'***
0MCB h485 8 2 273 PI pg 8891 ggp a
UNIT 2                                                                                                                  '"'
0187 CVCS LOD p
Z, ym, "e
/
PUMP INSERVICE TESTING LOOP                                                                                                                                  aua                            -,      ww.
Ie 8'X 4' - M,
                                                                                                                                                            ^                        "^ "
=
2    08-P -O03                                                                                                                N/A          N/A      ISI-D- 271          1 (T 1 5
6, (Ig2) p SEALS QMCB
' 6RHT 5018 C
G P
NOTE: THIS IS A H
" OMCB b
LV QMCB 101 1 3'X2 g3 5 8-112D SIMPLIFIED DIAGRAM 4
PI 4 73 BS USED TO DEPICT A TEST HV 8473 274 PI MCB RHT pg CIRCUIT. REFER TO THE 485 h
I 8892 018 8 P8,I.D. FOR DETAILS.
a i
4'l 1
6 8'X6' M
O O
/P 2-1208-P6-003 g
g RHT 508
[XI CENTRIFUGAL H
LV i P 1
L J
5019 CHARGING PUMP 4 71 112E HV HV HS 801A 801B 1 @
508 471 FROM 2 LRHT MCB REFUELING TO RCS COLD LEGS RVST VATER STORAGE TANK av.


    . _ _ _ . . . _ .      . . , _ _ _ = _ . _ _ _ . . . . _ . _ _ _ . . _ _ _ . _ . . . . . .                _ _ .      . . _ _
==
4 BORIC ACID TRANSFER PUMPS (2-1208-P6-006 & 007)
o=,
;/'              System Function
.nc.m
                                                  -           Provides boric acid to the CVCS for use in RCS inventory control and makeup to systems requiring reactor grade borated water. The boric acid transfer system also provides boric acid for emergency boration of the RCS,
-u
!              Quantity                                      2 l
-2
Type Canned motor j              Manufacturer /Model                          Chempump Model GVH-1K
-as
'                                                                                                                                  i 4
=:
Design Flowrate                              75 gpm Design Head                                                                                                        )
9 WW Elit V5 IISLEB FGt PTT
235 ft.
*I s-as-se ca.
I Driver Type Electric motor kW                                    15.5 Speed 3450 rpm Power Supply                        4160V,60 Hz,3 phase i
sto irmus in arv.ns a r:4eam-e
Code Class                                    3
-._C iN v~s.S
  .O          Project Class                                  313 Outline Drawing 2X6AH02-45 & 2X6aH02-92 Instruction Book                              2X6AA07-10 Physical Location Aux Bldg, Level D, Rooms R-D106 & R-D123 P&lD                                            2X4DB118 Surveillance Procedure                          14811-2 Pump Test Loop Diagrams                        ISI-D-277 & ISI-D-278 Test Parameter Sheets                          Page 21-2 & 21-3 0
=ur."r>7 ~- anet asus Ps esem a e 55.
21 - 1                             Rev.O
Southern Company Services, Inc.FOR Southern Nuclear Operating Company
~
EE E E
.Yr""c*"*""""**""""
N V0GTLE ELECTRIC GENERATING PLANT K58'***
"e 3
UNIT 2 Z, ym, PUMP INSERVICE TESTING LOOP aua ww.
^
"^
2 08-P -O03 N/A N/A ISI-D-271 1 (T 1 5


(4 0
_ _ = _. _ _ _.... _. _ _ _.. _ _ _. _......
0(./                                                                       V Test Parameter Table - Pump 2-1208-P6-006 (Figure ISI-D-277)
BORIC ACID TRANSFER PUMPS 4
Instrumentaten Utilized             Ref.         Acceptable     Alert             Action Parameter         Test Frea.       I.D. NoJ3)     RanFe         Rea. Acc. Value         Range           Range             Range               Comments t
(2-1208-P6-006 & 007)
Speed (N)               NA               NA             NA             NA         NA           NA             NA               NA                 Constant speed driver Inlet Pressure           Qtr             PI-10115       -15 to +15     12%         NA           NA             NA               NA                 Relief Request RR-P-l (Pi)                                               psig t
;/'
Outlet                                                                                                                                                                                 !
System Function Provides boric acid to the CVCS for use in RCS inventory control and makeup to systems requiring reactor grade borated water. The boric acid transfer system also provides boric acid for emergency boration of the RCS, Quantity 2
Pressure           Qtr             PI-0113       0-160         12%         NA           NA             NA               NA                 NA                 i               i (Po) _                                             psig i
l Type Canned motor j
Manufacturer /Model Chempump Model GVH-1K i
4 Design Flowrate 75 gpm Design Head 235 ft.
)
Driver Type Electric motor kW 15.5 Speed 3450 rpm Power Supply 4160V,60 Hz,3 phase i
Code Class 3
.O Project Class 313 Outline Drawing 2X6AH02-45 & 2X6aH02-92 Instruction Book 2X6AA07-10 Physical Location Aux Bldg, Level D, Rooms R-D106 & R-D123 P&lD 2X4DB118 Surveillance Procedure 14811-2 Pump Test Loop Diagrams ISI-D-277 & ISI-D-278 Test Parameter Sheets Page 21-2 & 21-3 0
21 - 1 Rev.O
 
(4 0(./
V0 Test Parameter Table - Pump 2-1208-P6-006 l
(Figure ISI-D-277)
[
Instrumentaten Utilized Ref.
Acceptable Alert Action Parameter Test Frea.
I.D. NoJ3)
RanFe Rea. Acc.
Value Range Range Range Comments t
Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-10115
-15 to +15 12%
NA NA NA NA Relief Request RR-P-l l
(Pi) psig t
Outlet Pressure Qtr PI-0113 0-160 12%
NA NA NA NA NA i
i (Po) _
psig i
Differ.
Differ.
Pressure           Qtr             NA(1)         NA             12%         APr           .90 - 1.10APr   NA               <.90 or >l.10APr NA                                     ;
[
(AP)
Pressure Qtr NA(1)
Flowrate           Qtr             FI-40001     0-100           2%         Qr           NA             NA               NA                 Flowrate is set at reference value (Q)                                               gpm                                                                                                                                 ,
NA 12%
Vib.
APr
Amp.               Qtr             (2)           NA             i5%         Vr           5 2.5Vr         > 2.5Vr - 6Vr     >6Vr or           NA                                   ;
.90 - 1.10APr NA
(V)(4)                                                                                                     or >.325 in/s     >.70 in/s                                               .
<.90 or >l.10APr NA (AP)
Notes:
Flowrate Qtr FI-40001 0-100 2%
: 1. Differential pressure is calculated as, AP = Po - Pi
Qr NA NA NA Flowrate is set at reference value
(
(Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr 5 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
[
: 1. Differential pressure is calculated as, AP = Po - Pi l
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                       j
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial           j direction on each accessible thrust bearing housing.                                                                                                                               !
j
21-2                                                               Rev.0                 !
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial j
t
direction on each accessible thrust bearing housing.
21-2 Rev.0 l
l t


O                                                                               O                                                                       O Test Parameter Table - Pump 2-1208-P6-007 (Figure ISI-D-278)
O O
Instrumentation Utilized           Ref.           Acceptable     Alert           Action Parameter         Test Frea,         LD. NoJ3)     RanFe         Rea. Acc-   Yalue         Range           Range           Range             Comments Speed (N)                 NA               NA           NA           NA           NA             NA             NA             NA                 Constant speed driver Inlet Pressure           Qtr               PI-10116     -15 to +15   i2%         NA             NA             NA             NA                 Relief Request RR-P-1 (Pi)                                               psig Outlet Pressure           Qtr               PI-Oll4       0-160         12%         NA             NA             NA             NA                 NA                   i (Po)                                               psig i
O Test Parameter Table - Pump 2-1208-P6-007 (Figure ISI-D-278)
Differ.
Instrumentation Utilized Ref.
Pressure           Qtr               NA(1)         NA           12%           APr           .90 - 1.10APr   NA             <.90 or >l.10APr NA (AP)
Acceptable Alert Action Parameter Test Frea, LD. NoJ3)
Flowrate           Qtr               FI-40001     0-100       12%           Qr             NA             NA             NA                 Flowrate is set at reference value !
RanFe Rea. Acc-Yalue Range Range Range Comments Speed (N)
(Q)                                               gpm Vib.
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-10116
Amp.               Qtr               (2)           NA           i5%           Vr             s 2.5Vr         > 2.5Vr - 6Vr   >6Vr or           NA                                 i (V)(4)                                                                                                       or >.325 in/s   >.70 in/s Notes:
-15 to +15 i2%
: 1. DilTerential pressure is calculated as, AP = Po - Pi                                                                                                                             i
NA NA NA NA Relief Request RR-P-1 (Pi) psig Outlet Pressure Qtr PI-Oll4 0-160 12%
NA NA NA NA NA i
(Po) psig l
i Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr FI-40001 0-100 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA i
(V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. DilTerential pressure is calculated as, AP = Po - Pi i
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                     i
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
i
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial I
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial I
direction on each accessible thrust bearing housing.
direction on each accessible thrust bearing housing.
i l
i l
1 t
1 t
21 - 3                                                           Rev.0 i
21 - 3 Rev.0 i
 
Q) p]
L
\\J NOTE THIS IS A V
SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TO THE (x-800) ''
I P&I.D.
FOR DETAILS.
TD BORIC FROM BRS RECYCLE LO LD EVAPORATOR b,
Z Z
2' ER N
Olle N
Nl X
lll 0
1l 2ma m
L1 (1
1 2, D LO LO 1N, K: = lI:
M
=X 1
e am m
I BORIC ACID 000 TRANSFER PUMP LC BORIC ACID FILTER BYPASS 2' BORIC ACID 2-1208-P6-006 2*
n 7'
TO BORIC ACID BLENDER STORAGE TANK SEE ISI-D-277 N
2-1208-T4-003 3* FUTURE OMCB c28mM'o J L I
114 3'
PP 011
, tg
', C N
X
= 3,>. (O LO L
1, 3 -
X e
e Mc.
e 3-, casa) ce m x x SAMPLE O
U 2-1
-P6- 07 B
Y ACID TRANSFER PUMPS TO UNIT 1 BORIC TRANSFER PUMP
-v.
mn e,
o.c.
 
== ===
-u
-u
-s


Q)                                                                            p]
==
L                                                                                                                                          \J NOTE THIS IS A                                                                                                                                                                                      V SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TO THE                                                                                                                                                                    I P&I.D. FOR DETAILS.                                                                                                                                                  (x-800) '''
e e-es-en ct.
FROM BRS RECYCLE                                                                                                            LO                                            LD                          TD BORIC EVAPORATOR                                                              b,                                                                                                                                    2' Z                                          Z                                ER Olle
=>
                                                                                                                                                                  @                                      N N
rssas rm m i m JJC i
1                                                            X              lll                                                0 l Nl m                                          L1 (1
wu+
2ma 1
uv
LO                        2, D      LO 1N, K: = lI:
.ma uvms un ruw wa JJC e
M                    :*:                              =X 1                                  e                      am                                m I              BORIC ACID 000          TRANSFER PUMP                                                                                              LC BORIC ACID                                          2-1208-P6-006                                                                                      2*    n                    BORIC ACID FILTER BYPASS 2' STORAGE TANK                                          SEE ISI-D-277                                                                                            7' TO BORIC ACID BLENDER 2-1208-T4-003                                                                                                                                                N 3* FUTURE                                                  OMCB
im m
                                            ,,                c28mM'o J  L 3'
M3 mm.
I    PP                                            114 011
m caan m
                                                                                                                                                              , tg LO            L 3,>. (O                    :  ', C          N                  X 1,
Southern Company Services. Inc. FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT==* =
                            . 3 -                        X                              ,
n=='
                                                                                                =        .
c' UNIT 2 o==a
e                    e Mc.              e            3-, casa)
=>
SAMPLE ce m O        xx    U                          2-1 B
                                                                                                                    -P6- 07 TO UNIT 1 BORIC                        TRANSFER PUMP
-v. mn        e, Y ACID TRANSFER PUMPS o.c.                      == = ==              -u    - . ,    -u    -.  -s          ==
e     e-es-en ct.     =>   rssas rm m i m                           JJC i     wu+     uv     .ma   uvms un ruw wa                           JJC e     im       m       M3     mm. m caan                             m Southern Company Services. Inc. FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT ==* =                                                                           n=='                   c' UNIT 2                               ""                                o==a                                 =>
                                                                                                                                                                        ==1            -                  carmas a sun PUMP INSERVICE TESTING LOOP FOR                                                  esaum                  a.                            -. mu,  ...
BORIC ACID TRANSFER PUMP r                                                                                                      2-1208-P6-007                                N/A              N/A          ISI-D- 278                                  1 IT 1 2


                    %                                                                                                                                                              N/                                                                                 ,/
==1 carmas a sun PUMP INSERVICE TESTING LOOP FOR esaum a.
NOTE THIS IS A SIMPLIFIED DIAGRAM                                                                                                                                                                                                                           V USED TO DEPICT A TEST CIRCUIT. REFER TO THE                                                                                                                                                                                                                         I Pt. L D. FOR DETAILS.                                                                                                                                                                                                       (x-90rD '''
mu, BORIC ACID TRANSFER PUMP r
FROM BRS RECYCLE                                                                                                                                                                             Lu                     LD     TO BORIC ,
2-1208-P6-007 N/A N/A ISI-D-278 1 IT 1 2
EVAPORATOR                                                                                                                                       $,                                  X                                       _2 X
L
CHRD                     GU7) 011
 
['   ,     i                                                                                                                         X             li;                                     o hJ                                                                                                                                     LD                             3   r
N/
                                                          ,                                                                                                                                                                 JL                                      i m                                                                                                                       El                                 LA       i 1 h >C     2 '; ;,;
,/
r 2'       _
NOTE THIS IS A SIMPLIFIED DIAGRAM V
1                                                           e             am                           e I                         BORIC ACID 000                   TRANSFER PUMP                                                                                                                                                     LC BORIC ACID                                                     2-1208-P6-007                                                                                                                                         2'         n             BORIC ACID FILTER BYPASS 2*
USED TO DEPICT A TEST CIRCUIT. REFER TO THE I
STORAGE TANK                                                     SEE ISI-D-278                                                                                                                                                     7' TO BORIC ACID BLENDER 2-1208-T4-003                                                                                                                                                                                                                     N 3' FUTURE                                                                                                                                   QMC (282)} LO                                                                                                                                                                                             ,
Pt. L D.
d '                                                                                                               'I 3'                                     PP                                   11 3 011
FOR DETAILS.
                                                                                                                                                                                                        .                  .      LO LD N
(x-90rD '''
1,3,=                                     x L                                        :    0                      X
FROM BRS RECYCLE Lu LD TO BORIC,
                                                                                                                                                                                =3'> (O M c=,                       e                                                                           3'       e83) e           e SAMPLE e
EVAPORATOR X
(@                                                           Ws                                $                            2-B I Ab TO UNIT 1 BORIC                                                                                               TRANSFER PUMP
X
=v. mars       =v   on Y ACID TRANSFER PUMPS
_2 CHRD GU7) 011
                                                    = = - - . _                                                                                       -u   -.,      -.,      .    .  -
[',
e    n-as-as          as ct.           tsmas ran en i en                                                                                                       JJC was-e+   uv     =       wvrus un rtow em                                                                                                         JJC
i X
                "              ~ ~ " ~ '
li; o
Southern Company Services, Inc.rOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT = = = < * ^~:                         naa=   ca-UNIT 2                         """                  a=*     me
hJ LD 3 r JL i
                                                                                                                                                                                                                                                  ~
,m El LA i
PUMP INSERVICE TESTING LOOP FOR BORIC ACID TRANSFER PUMP
1 h >C '; ;,;
                                                                                                                                                                                                                                                      =ana   SEU'          wr  av.
2' 2
2-1208-P6-006                         N/A       N/A   ISI-D- 277   1 (T 1 2
r 1
e am e
I BORIC ACID 000 TRANSFER PUMP LC BORIC ACID 2-1208-P6-007 2'
n BORIC ACID FILTER BYPASS 2*
STORAGE TANK SEE ISI-D-278 7'
TO BORIC ACID BLENDER 2-1208-T4-003 N
3' FUTURE QMC (282)} LO d '
'I 3'
PP 11 3 011 LO LD L
=3'> (O 0
N X
1,3,=
x e
e M c=,
e 3'
e83) e W s
(@
2-SAMPLE B I Ab Y ACID TRANSFER PUMPS TO UNIT 1 BORIC TRANSFER PUMP
=v.
mars
=v on
= = - -. _
-u e
n-as-as ct.
as tsmas ran en i en JJC was-e+
uv
=
wvrus un rtow em JJC
~ ~ " ~ '
Southern Company Services, Inc.rOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT = = = < * ^~:
naa=
ca-UNIT 2 a=*
me PUMP INSERVICE TESTING LOOP FOR SEU' wr
~
=ana av.
BORIC ACID TRANSFER PUMP 2-1208-P6-006 N/A N/A ISI-D-277 1 (T 1 2


s.
s.
4                                                                                                                                         ,
4 AFW Pumps t
t AFW Pumps (2-1302-P4-001,002 & 003)                                                         :
(2-1302-P4-001,002 & 003) 1/
1/                 System Function
System Function Supply water to the steam generatore whenever the reactor i
_            Supply water to the steam generatore whenever the reactor i
coolant temperature is above 350'F and the main feedwater system is not in operation, i.e., during startup, cooldown, or emergency conditions resulting in a loss of main feedwater.
coolant temperature is above 350'F and the main feedwater system is not in operation, i.e., during startup, cooldown, or             ;
c Automatically provides feedwater for the removal of reactor core decay heat following a loss of main feedwater.
;                                                              emergency conditions resulting in a loss of main feedwater.               !
This prevents damage to the reactor core until the reactor coolant temperature is brought from a Hot Standby condition to the point at which RHR may be placed ir.to j
c
operation.
:                                                              Automatically provides feedwater for the removal of                       :
reactor core decay heat following a loss of main feedwater.               '
This prevents damage to the reactor core until the reactor coolant temperature is brought from a Hot Standby                         '
condition to the point at which RHR may be placed ir.to j                                                               operation.
l AFW supplies feedwater to the steam generators at a j
l AFW supplies feedwater to the steam generators at a j
flowrate sufficient to support normal low-power transients i
flowrate sufficient to support normal low-power transients i
                                              -                such as stanup, cooldown, and hot standby.
such as stanup, cooldown, and hot standby.
4
4 Turbine Driven AFW Pumo (2-1302-P4-001) j Quantity 1
;                  Turbine Driven AFW Pumo (2-1302-P4-001) j                   Quantity                                   1 i
i a
a                                                                                                                                         ,
4 Type Horizontal, centrifugal,5 stage, split-case b
4 Type Horizontal, centrifugal,5 stage, split-case i
i i y Manufacturer /Model Ingersoll-Rand, Model 6HMTA i
i y b            Manufacturer /Model                         Ingersoll-Rand, Model 6HMTA i
Capacity 1175 gpm l
Capacity                                   1175 gpm l                 Total Dynamic Head                         3500 ft.
Total Dynamic Head 3500 ft.
1 4
1 Driver 4
Driver i                             Type Terry Turbine, Model GS-2N, non-condensing, single-i                                                             stage, mechanical drive
i Type Terry Turbine, Model GS-2N, non-condensing, single-i stage, mechanical drive Horsepower 1603 j
,                            Horsepower                       1603 j                             Speed                           4250 rpm Power Supply                   Steam
Speed 4250 rpm Power Supply Steam
;                                                                                                                                          )
)
Code Class                                 3 i                                                                                                                                         I
Code Class 3
+
i
(                 Project Class                               313 4
+
i Outline Drawing                             2X4AF03-88
(
  !              Instruction Book                           2X4AF03-20031
Project Class 313 4
  !O i
i Outline Drawing 2X4AF03-88 Instruction Book 2X4AF03-20031
22 - 1                                       Rev.O I
!O i
22 - 1 Rev.O I


    . . _    . . - . - . - - - . . - - . . . - . . . _ . - . . . . . -                  . ~.... .. . .. ... . - -..-.. - - . .
. ~......
i Turbine Driven AFW Pumn (2-1302-P4-001) (cond A
Turbine Driven AFW Pumn (2-1302-P4-001) (cond i
Physical Location lO AFW pump house i V P&ID                                                         ~
A lO Physical Location AFW pump house
:i V P&ID
~
2X4DB161-2 I
2X4DB161-2 I
a j         Surveillance Procedure                                         14810-2
a j
!        Pump Test Loop Diagrams                                                                                               i t
Surveillance Procedure 14810-2 Pump Test Loop Diagrams ISI-D-272 t
ISI-D-272 i
i Test Parameter Sheets Page 22-4 4
4 Test Parameter Sheets                                         Page 22-4                                             !
                                                                                                                              )
1 I
1 I
l l
l i
l l
l i
i l
22 - 2 Rev.0
i 22 - 2                   Rev.0


Motor-Driven AFW Pumos (2-1302-P4-002 & 003) j             Quantity                                       2 1
Motor-Driven AFW Pumos (2-1302-P4-002 & 003) j Quantity 2
!hv            Type                             -
1
f                                                            Horizontal, centrifugal, 6 stage, split-case
!h Type Horizontal, centrifugal, 6 stage, split-case v
{             Manufacturer /Model                             Ingersoll-Rand, Model 4HMTB Design Flowrate                                 630 gpm Total Dynamic Head                             3500 ft.
f
Driver Type                                                                                                               I Westinghouse electric motor, LLD 5810 H Horsepower                             900                                                                         !
{
i Speed                                   3600 rpm Power Supply                           4160V,60 Hz,3 phase Code Class                                     3 Project Class                                   313 Outline Drawing                               2X4AF03-87 Instruction Book 0         Physical Location 2X4AF03-20030 AFW pump house P&ID                                           2X4DB161-2 Surveillance Procedure                           14807-2 I
Manufacturer /Model Ingersoll-Rand, Model 4HMTB Design Flowrate 630 gpm Total Dynamic Head 3500 ft.
Pump Test Loop Diagrams                         ISI-D-273 & ISI-D-274 Test Parameter Sheets                           Page 22-5 & 22-6 l
Driver Type Westinghouse electric motor, LLD 5810 H Horsepower 900 i
22 - 3                                         Rev.O
Speed 3600 rpm Power Supply 4160V,60 Hz,3 phase Code Class 3
Project Class 313 Outline Drawing 2X4AF03-87 Instruction Book 2X4AF03-20030 0
Physical Location AFW pump house P&ID 2X4DB161-2 Surveillance Procedure 14807-2 Pump Test Loop Diagrams ISI-D-273 & ISI-D-274 Test Parameter Sheets Page 22-5 & 22-6 22 - 3 Rev.O


O                                                                                           O                                                                                                   O Test Parameter Table - Pump 2-1302-P4-001 (Figure ISI-D-272)
O O
Instrumentation Utilized                           Ref.           Acceptable                       Alert                     Action Parameter                         Test Freq.     LD. No.(3)     Range       Rea. Acc.                     Value         Range                             Range                     Range             Comme::ts Speed (N)                               Qtr             SI-15109A       0-6000       12 %                         Nr           NA                                 NA                       NA                 Speed is set to reference value Inlet Pressure                         Qtr             PI-5110A       0-30         i2%                           NA           NA                               NA                         NA                 NA (Pi)                                                               psig Outlet Pressure                           Qtr             PI-5107A       0-2000     i2%                           NA           NA                               NA                         NA                 NA                 i (Po)                                                               psig Differ.
O Test Parameter Table - Pump 2-1302-P4-001 (Figure ISI-D-272)
Pressure                           Qtr             NA(1)           NA         12%                           APr           .90 - 1.10APr                     NA                         <.90 or >l .10APr NA (AP)
Instrumentation Utilized Ref.
Flowrate                           Qtr             F1-15100       0-200       i2%                           Qr           NA                               NA                         NA                 Flowrate is set at reference value (Q)                                                                 gpm Vib.
Acceptable Alert Action Parameter Test Freq.
,                                                    Amp.                               Qtr             (2)             NA         15%                           Vr           5; 2.5Vr                         > 2.5Vr - 6Vr               >6Vr or           NA (V)(4)                                                                                                                                                         or >.325 in/s             >.70 in/s Notes:
LD. No.(3)
Range Rea. Acc.
Value Range Range Range Comme::ts Speed (N)
Qtr SI-15109A 0-6000 12 %
Nr NA NA NA Speed is set to reference value Inlet Pressure Qtr PI-5110A 0-30 i2%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-5107A 0-2000 i2%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr F1-15100 0-200 i2%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA 15%
Vr 5; 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.                                                                                                                                                                           ,
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
22 -4                                                                                         Rev.0
22 -4 Rev.0


_ . . _ . _ . - . _ _ . _ . . . . _ _ _ .                        . . . _ _ _ _ _ . _ . . . . _ _ _ _ . _ . . . _ . _ _ ~                               ._        _                - . _ . _
... _ _ _ _ _. _.... _ _ _ _. _... _. _ _ ~
Test Parameter Table - Pump 2-1302-P4-002 (Figure ISI-D-273)                                                                                                                                 i Instrumentation Utilized                                                   Ref.       Acceptable           Alert                           Action Parameter                               Test Freq.                                                                                                 I.D. No.(3)                                                             Rance               Req. Acc.               Value       Ranee               Range                             Range                         Comments Speed (N)                                     NA                                                                                                       NA                                                                       NA                 NA                       NA         NA                   NA                               NA                             Constant speed driver                               [
Test Parameter Table - Pump 2-1302-P4-002 (Figure ISI-D-273) i Instrumentation Utilized Ref.
Inlet Pressure                                 Qtr                                                                                                       PI-5128A                                                                 0-30               12%                     NA         NA                   NA                               NA                             NA                                                 .
Acceptable Alert Action Parameter Test Freq.
i (Pi)                                                                                                                                                                                                                         psig                                                                                                                                                                                             i i
I.D. No.(3)
Outlet Pressure                               Qtr                                                                                                       PI-5140A                                                                 0-2000             12%                     NA         NA                   NA                               NA                             NA                   i (Po)                                                                                                                                                                                                                         psig                                                                                                                                                                                             ,
Rance Req. Acc.
Differ.
Value Ranee Range Range Comments Speed (N)
Pressure                                 Qtr                                                                                                       NA(1)                                                                     NA                 12%                     APr       .90 - 1.10APr       NA                               <.90 or >l.10APr NA (AP)                                                                                                                                                                                                                                                                                                                                                                                                                           1 I
NA NA NA NA NA NA NA NA Constant speed driver
Flowrate                                 Qtr                                                                                                       FI-15101                                                                 0-200               12%                     Qr         NA                   NA                               NA                             Flowrate is set at reference value (Q)                                                                                                                                                                                                                           gpm Vib.
[
Amp.                                     Qtr                                                                                                       (2)                                                                       NA                 15%                     Vr         5 2.5Vr             > 2.5Vr - 6Vr                   >6Vr or                         NA (V)(4)                                                                                                                                                                                                                                                                                                     or >.325 in/s                   >.70 in/s r
Inlet Pressure Qtr PI-5128A 0-30 12%
Notes:                                                                                                                                                                                                                                                                                                                                                                                                                         l
NA NA NA NA NA i
: 1. Differential pressure is calculated as, AP = Po - Pi
(Pi) psig i
: 2. Portable vibration instruments are utilized.                                                                                                                                                                                                                                                                                                                                                                                 ;
i Outlet Pressure Qtr PI-5140A 0-2000 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP) 1 Flowrate Qtr FI-15101 0-200 12%
Qr NA NA NA Flowrate is set at reference value I
(Q) gpm Vib.
Amp.
Qtr (2)
NA 15%
Vr 5 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s r
Notes:
l 1
: 1. Differential pressure is calculated as, AP = Po - Pi l
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearmg housing and in the axial                                                                                                                                                                                                                                                     i direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearmg housing and in the axial i
22-5                                                                                               Rev.0                                 ,
direction on each accessible thrust bearing housing.
k 22-5 Rev.0


o                                                                             o                                                                   o Test ParameterTable - Pump 2-1302-P4-003 (Figure ISI-D-274)
o o
Instrumentation Utili=1                       Ref.       Acceptable       Alert         Action Parameter                                           Test Frea. LD.No.01     Range                   Reg. Acc. Value       Raare           Range         Rance           Comments Speed (N)                                                 NA         NA           NA                       NA           NA         NA               NA           NA               Constant speed driver                 i inlet                                                                                                                                                                                                                   i Pressure                                             Qtr       PI-5129A     +10                       12%           NA         NA               NA           NA               NA                                     -
o Test ParameterTable - Pump 2-1302-P4-003 (Figure ISI-D-274)
(Pi)                                                                         pug Outlet Pressure                                             Qtr       PI-5141 A   0-2000                   12%           NA         NA               NA           NA               NA                   i                 :
Instrumentation Utili=1 Ref.
(Po)                                                                         psig                                                                                                                                       j Differ.                                                                                                                                                                                                                 [
Acceptable Alert Action Parameter Test Frea.
Pressure                                             Qtr       NA(1)       NA                       12%           APr         .90 - 1.10APr   NA           <.90 or >l.10APr NA                                     ;
LD.No.01 Range Reg. Acc.
(AP)                                                                                                                                                                                                                   ;
Value Raare Range Rance Comments Speed (N)
Flowrate                                             Qtr       F1-15102     0-200                     12%           Qr         NA               NA           NA               Flowrate is set at reference value     I (Q)                                                                         gpm                                                                                                                                       ;
NA NA NA NA NA NA NA NA Constant speed driver i
Vib.
inlet i
Amp.                                                 Qtr       (2)         NA                       i5%           Vr         52.5Vr           > 2.5Vr - 6Vr >6Vr or         NA                                     i (V)(4)                                                                                                                                           or >.325 in/s >.70 in/s                                               f r
Pressure Qtr PI-5129A
Notu:                                                                                                                                                                                                                   l
+10 12%
NA NA NA NA NA (Pi) pug Outlet Pressure Qtr PI-5141 A 0-2000 12%
NA NA NA NA NA i
(Po) psig j
Differ.
[
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr F1-15102 0-200 12%
Qr NA NA NA Flowrate is set at reference value I
(Q) gpm Vib.
Amp.
Qtr (2)
NA i5%
Vr 52.5Vr
> 2.5Vr - 6Vr
>6Vr or NA i
(V)(4) or >.325 in/s
>.70 in/s f
r Notu:
l
: 1. Di Terential pressure is calculated as, AP = Po - Pi
: 1. Di Terential pressure is calculated as, AP = Po - Pi
: 2. Po: table vibration instruments are utilized.
: 2. Po: table vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.                                                       ;
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.                                                                                                                                                       ;
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
L 22 - 6                                                         Rev.0 i
L 22 - 6 Rev.0 i
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _                            .___m_____ .___ _ . _ .          _ -    . , _ _  .    . .  .. .        -.          -.  -                            -            .
m


(S                                                                                                                                                                                             (g                                                                                                                                                       g N                                                                                                                                                                                               N LD                                                 2.5" CONDENSATE               CONDENSATE                     TE                   15 9                                                                                                 510                                                                                                                                         LD           3*X2 1/2"                             2.5" 5175                                                                                                                                                                FROM MAIN                                                                     ,                                                  i STORAGE TANK             STORAGE TANK                                                                                                                                                                                     ## MEM 2-1302-V4-002       _   2-1302-V4-001                 ;,                            sy                                                                                                                                                                                                                 $                                                          0 15133                                           sg                                             g                                                                 OMCB p          'c3     7, 5 0              5 3     5110A
(S (g
                                                  -o                                                                                                                                     '                              MCB                                                                      -
g N
0           I
N LD 2.5" CONDENSATE CONDENSATE TE 15 9 510 LD 3*X2 1/2" 2.5" FROM MAIN STORAGE TANK STORAGE TANK 5175 i
_J                    QMCB g                                                                                                                                      i                                                             6*                                 cu               I
## MEM 0
                                                                                                                                                                                                                                                                                                                              \,
2-1302-V4-002
__                              i                     . t                                                                                                   j                                                                                                                                 i Sf                                j                                                                                                                 T TURBINE DRIVEN                                                                                                                           COTT)                   E
_ 2-1302-V4-001 sy 15133 sg g
                              --                        0                            '' \                                                                                  e                                2-1302-P4-001                                                                                   -    -
OMCB
AUX FEEDVATER                                                                                                                                                                                                                              0 W
'c3 p
            -@0                      HV HS 5113                  PUMP TURBINE 2-1302-P4-001-K01 10' / XI T FEEDVATER PUMP AUX cu   cu             -
7, 5 3 5110A MCB 5 0
NOTE THIS'IS A SIMPLIFIED DIAGRAM 3[                     5113                                                                                                 TD FV                                            8[_-                      USED TO DEPICT A TEST           ,
-o
(U5T)                                   ATMOSPHERE                                                                                                                                                                                                                                                   CIRCUIT. REFER TO THE           '
_J QMCB 0
T                        10'                                                                                                                                                                                                                                     5154
I g
                                              'N '                       QMCB                                                                   H                                                     M  5140                                                                                         2 1/2*X2'
i 6*
                                                                                                                                                                                                                                                                                                                                      ]    [FROM CHEM.
cu I
g' ' INJECTION
\\,
                                                                                                                                                                                                                                                                                                                                                                            ^
i Sf
HV                                 HV                                 128                                                                                                                                                             MCB 5094                                                                                                   !                                                                                                                                                                (UDD             g         (UM)
. t j
Sj[_5098                               8'     g                  8                           8' j                                                                4, lll                ,                                                                ,
i
HV LD m               2-1302-P4-002                                                                                                                                                                                                                                           $
-@0 0
5118                                                                                                                                        X                                                                          FV                                                                     8       -
j
2' FEED ATER g,
'' \\
PUMP                                                                                     5035                                                                         5155                                                                         y   1   [
T TURBINE DRIVEN COTT)
                                          ;            '    =                                                                                                                                                                                                                                                                   3 OMC HV 5092--
E 2-1302-P4-001 HS AUX FEEDVATER e
QMCB HS 131A Q 5141A 2 1/2*X2*               ,2 '
AUX 0 W PUMP TURBINE 10' / XI T FEEDVATER cu cu NOTE THIS'IS A HV 5113 2-1302-P4-001-K01 PUMP 8[_-
SIMPLIFIED DIAGRAM 3[
5113 TD USED TO DEPICT A TEST T
(U5T)
ATMOSPHERE FV CIRCUIT. REFER TO THE 10' 5154 M
] [FROM CHEM.
^
'N '
QMCB H
5140 2 1/2*X2' g' ' INJECTION HV HV 128 MCB 5094 (UDD g
(UM)
Sj[_5098 4,
j lll 8'
8' 8
g LD m 2-1302-P4-002 HV X
FV 8
2' 5118 FEED ATER PUMP 5035 5155 y
1 [
g,
=
3 OMC HV HS Q
2 1/2*X2*
,2 '
QMCB 131A 5141A
(
(
HV                                     I9 5095                                                                                                        ,
5092--
y[                 g HV              --
HV I9 y[
5099                U                              O            8*                         8'X6'                                                                                 3 4'
HV 5095 g
                                                                                                                                                                                                                                                                                                  'i A' 3--                             HV                 LD E                                  '        -
8*
2-1302-P4-003                                                                                         XI 5119             g                              AUX 8'                 -
8'X6' 3
                                                      ,    8'            FE g TER
4' U
_      .        . _                                ._                          -                              _.                            _                                              .            _                                    _s
O
.      *s-w   ==   vs       usure r= es,                                             FT i       im-se et   et s     ww.ts to acvas a rienesi-a                           JJC
'i A' 5099 E
*      ~     "            " " " * "
3--
Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT KI"' "                                                                                ==   "c UNIT 2                                 [', _            Z, y_
HV LD 2-1302-P4-003 5119 AUX XI 8'
PUMP INSERVICE TESTING LUDP                                                                       ui.     .,            ,,,1, c.
g FE g TER 8'
FOR AUXILLARY FEEDVATER PUMP 2-1302-P4 -001                                   N/A   N/A   ISI-D- 272     10F 1 2     s
_s
*s-w
 
==
vs usure r= es, FT i
im-se et et s ww.ts to acvas a rienesi-a JJC
~
Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT KI"'
 
==
"c UNIT 2
[',
Z, y_
PUMP INSERVICE TESTING LUDP ui.
,,,1, c.
FOR AUXILLARY FEEDVATER PUMP 2-1302-P4 -001 N/A N/A ISI-D-272 10F 1 2
s


S
S
                    %J                                                                                                                                                                             %./                                                                                                 L]
%J
PV                                                                                         w 4*
%./
                                                                                                                                                                                                                                          -                                l                                 -l CONDENSATE              CONDENSATE                  TE              15129                                                                              5106 FRON MAIN                                    LD                  3*X21/2                   @ 2.5*
L]
STORAGE TANK             STORAGE TANK               5175
PV w
                                                                                                                                                                                                                            # NU                                                     gG 2-1302-V4-002         _ 2-1302-V 4 -001             ;;                    sy                                                                                                                                                                                                                     3 i i a
l
HV                                                                                                                                                                                        {                                         _ _
-l 4*
5093 5 0       --aJ 5110A OMCB                                                                       /
3*X21/2
MCB                          -
@ 2.5*
                                                                                                                                                                            '                                                                    l
CONDENSATE CONDENSATE TE 15129 5106 LD FRON MAIN STORAGE TANK STORAGE TANK 5175
                              ..                                                >            f                                                                                                                                                         N
# NU gG i i 2-1302-V4-002
_                      D     _)AUX FEEDVATER    '\                                                                                               h_jh f4k0                                           "
_ 2-1302-V 4 -001 3
r n 0                         HS                                                                                                                                                                         AUX                 n; ni HV                        PUMP TURBINE                   10'                                                     XI                                             FEEDVATER                                                                         NOTEi THIS ilS A 5113           -1302-P4-001-K01 TO                                                                                                                                                                                                          SIMPLIFIED DIAGRAM Sjd,                     5113 PUMP                            $
sy
n[_
{
FV                      S USED TO DEPICT A TEST l                       10'              @                        ATMOSPHERE 5154                                                      CIRCUIT. REFER TO THE QMCB                                 H                                                                                       p1                                                           ]     [
a HV 5093 5110A MCB 5 0
                                              'N                                                                                                                                                                                                                      'FROM CHEM.
--a l
HV                              HV                          128                                                                                                                                          2MCB    @        1/2'X2'       e'           INJFCTION 5094                                                                                                                                                                                                  GED           A           @
J OMCB
3[5098 q7 8'
/
                                                ; 4            8' O~h j                                                               4, N                     6 HV              LO G159)h       2-1302-P4-002                                                                                                                                                                         $
f N
5118                                FEED ATER                                                                            \
D
I                                                               FV 5155 S
_)
m 2'
'\\
PUMP                                                                                                                                                                                   1 [
h_jh f4k0 "
1!
0 HS AUX FEEDVATER AUX r
HV 8,         i
n PUMP TURBINE 10' XI FEEDVATER n;
                                        '    W           -
ni NOTEi THIS ilS A n[_
QMC M OMCB p                                            2 1/2*X2' 2~
HV 5113
MCB                               131 I
-1302-P4-001-K01 PUMP SIMPLIFIED DIAGRAM
HV                                                                                                                                  5141A 5092--o                                             5129                                                                                                                                                                                 _'
: Sjd, 5113 TO S
HV                  -_J         5095 4,
USED TO DEPICT A TEST l
g 5099                N                   ,                8'             8'X6' W
ATMOSPHERE FV CIRCUIT. REFER TO THE 10' 5154
I DA'               -
'N QMCB H
e B
p1
p 0 7                                                                                                                                                                                                                                    (DUT)                               l LO
] ['FROM CHEM.
-h_                            HV              'OL                2-1302-P4-003 5119                                     AUX                                                                     XI 8'                                     8'         FEgpTER
1/2'X2' e'
.v   ..        . _.                            . s__                   _. _,                      _.                                    _.                                      _.                            __s e     *w       ses   vs     issure a est                                     I
INJFCTION HV HV 128 2MCB GED A
        -es-se   et   ei.:   trwun m .vn er rnomi-e                       - JC L                                                                                                                                                                                                                           Southern Company Services. Inc.FOR Southern Nuclear Operating Company
5094 3[5098 4,
                                                                                                                                                                                                                                                                                  "                ==  =c V0GTLE ELECTRIC GENERATING PLANT 't='           ""'                    == vs UNIT 2 PUMP INSERVICE TESTING LOOP
q 7 O~h j
                                                                                                                                                                                                                                                                                      -,        $"      ,7r   mv .
N 8'
FOR AUXILLARY FEEDVATER PUMP 2-1302-P4-002                         N/A         N/A     ISI-D- 273   10F 1 2
8' 6
; 4 LO G159)h 2-1302-P4-002 HV
\\
I FV S
2' 5118 FEED ATER 1!
PUMP 5155 m 1 [
8, OMCB W
QMC M 2 1/2*X2' 2~
i HV p
MCB
' I 131 5141A 5092--o 5129 HV HV
-_J 5095 g
N 8'
8'X6' I
4, DA' e
p 5099 W
B
'O (DUT) l LO 7
0 L
2-1302-P4-003 HV
-h_
5119 AUX XI FEgpTER 8'
8'
.v
. s__
__s e
*w ses vs issure a est I
-es-se et ei.:
trwun m.vn er rnomi-e
- JC L
Southern Company Services. Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT 't='
 
==
=c
 
== vs UNIT 2 PUMP INSERVICE TESTING LOOP
,7r mv FOR AUXILLARY FEEDVATER PUMP 2-1302-P4-002 N/A N/A ISI-D-273 10F 1 2


l i
l i
T                                                                                                   y
T y
          *
SE n
* SE                                                                                                   n                 2 5               5                                           EH                                                                                                   a p                  1 2               2                                           TT                                                                                                               ,
2 5
M                                                                                                                           F m           .a,   0 AAO'                                                                                                   o
5 EH a
                          )            )
1 2
R       T   I                                                                                        C             gtp 9             0                       AACRGT      A                                                                                              g 6            7                                                                                                                                                     4
2 TT p
                          /            7 S DPF IIE                                                                                                   in   c
M m
                                                                                                                                                                                "    7'r    7 O                      (             (                     I EE t
.a, F0 AAO' o
a     ,
R T
                                                                                                                                                                                      $2 SE DDR r                     -
C gtp I
e IIO     .                                                                                                   p    =     -    D I
)
I HF TT TI L U
)
* I O
GT A 9
0 AACR g
7'r O
' DDR 4
6 7
IIE in c
7
/
7 S DPF t
" $2
(
(
EE a
I r
=
SE e
7 I
D p
IIO.
O
=
HF TT I
TI I
S I
L U
* r I
:P D C a
E M ER e
g T ISI e,
li' OSUC lc A
/
u N
w O
2" N
N F
/
M N) n O6y 1
)
E 0
)
r
r
                                                                                                                                                                                  =
*2 H
                                                                                                                                                                                    ,7        I S
3 e
I
:P D C                                                                                                      a g
E ISI T  M ER                                                                                                    e e,              li' OSUC                                                                                                      lc            .      A N                                    -                                                                      u                  /
O                                                                                                                                        N            w      N F          2"                                        .
                                              /                                      M 1          )                            E  N)0                                            )
n r  "
H
* 2
                          /
I 2
I 2
X          0
C 0
h A
/
T
(
(
C T O6y I
3 X
C 0
0 C
2' o
u t
I
/
=
(
(
2' 3
3' M F o
3 o
(
(
ht u
N 2
e
O J S
                                                                                                                                                                                '            A
=
                                                                                                                                                                                                /
X R N.
3'                                     MF                                                                                    o    =            N 2                                                          OJ                                                                                  S X                                                          R FI p N.                                                                              R
3' FI p R
                                                                                                                                                                                =
T P
3'                                                                                                                                                O T
P U                D                                      [-
F '
F '
                                                                                                              - i '           I '                                         r   NA P M OU hU@h] 2'I ' -
O N P M
1 '                                                                                        .
[-
1   d c  L
1 '
      )                )L                             )
- i '
O)2                                                                            I n P      O L
I '
P 5                 5                               0                                                                                                                       G           R 0
r A
(                0
O U U
D
] 2'I ' -
c L
1 d
O P
)L O) hU@h I
P
)
n
)
L 4g3g N
2 G
R 5
5 0
0 s
N G E 0
0
(
(
(                                    0 0
N T 0
I e
(
(
N                                                                        s e
(
N I
(
T GE NT 4g3g I
T I
                        )                                                                                                                                                 i c A     T A3
)
    'O B
c A
6 8                                  hm                         2'                                 2'                                               v r R E
T A3
SV00 X                                 X                                                 e       ED D
'O iv R
(                 0i                        l S     gTE-C hm                         2' 2                                                   E EP 4
SV0 6
                                                                                        /                                                                                   y 1
hm 2'
                                                                                                                          /
2' r
1                                               n         EF-C a                   2
0 B
                    -                    -r N                                                                            I I Y 0
8 E
                                              '0 2                                 2                                               p m
ED X
X e
(
C S
gTE-D 0i l
hm 2'
E 4
2 EP
/
/
y EF-1 1
n C
2 a
I Y 0 r
2 N
2 p
R VR3 I
'0 m
T RA1 hPJmM o
C EL-5 N
C E
SL2 2
E 4
y L
NI N
V R
V5 n
E IX Am B E
F1 r
U I
R T
R T
VR3 RA1 5                                                                                                                                                                     o  C    EL-N                                                                                                                  C    E     SL2 2                                                E                      4                                                              y                                L     NI V5 hPJmM    N Am B I
5 e
M MM C
E PA I
V I
5 h
R D
L M
R E
M C
T AP F1 5
D AP B
B C ,                 V5 5
V5 t
                                                                                                                                                              ,          h t
T UR M M XVM C,
n r
u G
e u
M 4 F1 4
E E
PO p(.
L T
RN O N
G IX PA M
E DU o
UR U
0 5
N                           E     XVM                          M 4                  F1 5                        4                  -            o   0     PO O                   B     N A EP  DU                                                                                            -          S     V           F p(.                      RN O F                    C M
F O
I B
B N A S
R E
V EP C
F                 I P
I F
B C    g A
M B
1 V6 H0    1 5            g/id            U T
E B
E R
A I
I X
R F
M p4 O
U M p4 1
A 1
P C
5 I
g g/i I
1 E                   f h3 g                    0 OH 1
I V6 1
TP 1
T O
g                                                                                                                     .
5 H0 1
1 S                        '      2
5 d
* 3 R    0 OM                            6       0 0   R                                     0 0
X E
R     -
0 OH f
X             E                                         E V2 9
h3 A
y3 3                     E 1TA Ti                             8 8 T        0" 9 8 4
R 1
T 4 APM                                                ,
E 1
C g1 1
g TP 1
P15              g1                       Al0                                           P                                          P 1
g S
5 1                     VR0 B                          2 2 DU I
2 3
2
10 O 6
                                                                                                                                                      -      - iJJ t
0 R 0 R 0"
B       DU                   B t
R M
C M
X 0
ET+
0 E
E P C
E 9
M 0 h 3   E 0
3 E 1T g1 T
E 1
T V2 y3 Ti 9 8 4
F O       FP-2                 Q 1
8 8 4 AP P
F                                      -
A C
M0                                 ,    2                                   '
1 P1 g1 Al0 2
8 2
P
XU3                                     8 UP1 A -                                                                                   l 2                                                                               I
- iJ 5
                                                                                                        )
5 B
E7 T1 ;
M I
5 3                          )
VR0 t J 1
1 i
1 2 DU 2
8 5
B DU B
r                }
0 h 0
8  -
C ET+
5     ;                                      5                              0
C P
(                                                         e 0                                         )                                              s 5           0             (                                                                              )         w s
3 E 3 E t
1 4                                                   b K1 J-S13                          V9                      0 s.
M E
r e
M F
N 00                          H1                    'N H0               ;           (
1 1
ETT4 A
F O
A-                                 5                            5 8'
FP-Q 2
6@            V9 H0 5
2 M0 2
n v y
8 XU3 8
o i
UP1 A -
S NE-   V 0
l 2
V3 j                5                       e e   ~
I 5
G 2                                H1 1
i
                                                                          '0                                                                                    m o   "
)
EA0                  5                     5     1                               V18                                                    t n s DR3                                                                                H15                                                  a on
}
                                                                                                                                                                        ~
8 r
N O1                                                   -                                    ,                                          m a
E7 3
OT -                                                   -                                    B               O                         s  r  "
)
CS2 i  t
5 8
                                                                                '                                                  ~
T1 ;
N                                 _
1 5
2                                 s s
5 0
~/                          K 2                           9                                                             V9 H0
s e
                                                                                                                                                              -  v at N 00                        H0                                                                   5 EA T    T 4-5                               8                                                             8' -
(
A                                                                  V9                                                                    = e.
0 5
t S      V                                      T                 H0 N G EA2 E-                                 [3                          5 V9 9                     e e
0
e t-  '
)
DR0 NO3 O      1
)
w
(
6@
1 s
4 b
s.
J 3
V9 S1 r
0 e
K1 0
5
'N H0 ;
0 H1
(
N 5
5 y
E A-V9 i ~
o T T 4 8'
H0 v
A 0
NE-V3
'0 j
5 n e V
S e
1 8
m o "
G 2 5
H1 V1 n
t E A 5
1
~
s 0
H1 D R
, n 3
5 a
a N O1 m o "
OT -
B O
t CS2
~
i r "
s V9 N
2 s
s t
~
v a
K 2 9
/
N 0 H0 0
H0 5
EA 5
8 8'
- =
e."
T T t
V9
[3 A
4 T
H0 V
S E-5 9
e N
G V9 e e EA2
[
[
_3 H0 5
H0
                                                                                                                                                              , s
, s e t "
                                                                                                                                                              . s-e-
D R 0 5
C S2
. s-N O 3
                                                                                                                                                              -  e i   *
_3 O
                                                                                                                                                                                              'l     l
1 T -
C S2 e
i
'l l


  . - - - . - - . . . . - - -          . . - - . - . - . -                _ _ _ _ . -      - . - = - - . - . - . . . . .       - ,
-. - = - -. -. -.....
ESF Pumps (2-1592-P7-001, & 002)
ESF Pumps (2-1592-P7-001, & 002)
System Function
System Function During nonnal operation, the ESF chilled-water system is in
                                                            ~
~
During nonnal operation, the ESF chilled-water system is in standby mode; it is activated during emergency conditions upon receipt of a safety injection signal, containment ventilation isolation, or control room isolation signal. The
standby mode; it is activated during emergency conditions upon receipt of a safety injection signal, containment ventilation isolation, or control room isolation signal. The
                                                                . ESF chilled-water system serves air handling units located in the safety-related areas of the plant to ensure the integrity of the cooling system during plant emergency situation.
. ESF chilled-water system serves air handling units located in the safety-related areas of the plant to ensure the integrity of the cooling system during plant emergency situation.
Quantity                                         2 Type                                             Centrifugal Manufacturer                                     Goulds Capacity                                         600 gpm TotalDynamic Head                                 125 ft.
Quantity 2
Driver Type                                 Westinghouse electric motor Horsepower O                   Speed Power Supply 30 1800 rpm 480V,60 Hz,3 phase j
Type Centrifugal Manufacturer Goulds Capacity 600 gpm TotalDynamic Head 125 ft.
Code Class                                       3
Driver Type Westinghouse electric motor Horsepower 30 O
              - Project Class                                     313                                                               '
Speed 1800 rpm j
Outline Drawing                                   2X4AJ05-28 Instruction Book                                   AX4AJ05-86 Physical Location                                 Control Bldg, EL 260 ft., Rooms R-310 & R-308 P&ID                                             2X4DB221 Surveillance Procedure                             14809-2 Pump Test Loop Diagrams                           ISI-D-275 & ISI-D-276 Test Parameter Sheets                             Page 23-2 & 23-3 O
Power Supply 480V,60 Hz,3 phase Code Class 3
23 - 1                                             Rev.0
- Project Class 313 Outline Drawing 2X4AJ05-28 Instruction Book AX4AJ05-86 Physical Location Control Bldg, EL 260 ft., Rooms R-310 & R-308 P&ID 2X4DB221 Surveillance Procedure 14809-2 Pump Test Loop Diagrams ISI-D-275 & ISI-D-276 Test Parameter Sheets Page 23-2 & 23-3 O
23 - 1 Rev.0


I O                                                                                         O                                                             O Test Parameter Table - Pump 2-1592-P7-001 (Figure ISI-D-275)
I O
Instrumentation Utilized                         Ref.       Acceptable   Alert         Action Parameter         Test Frea.       1.D. NoJ3)   Range           Rea. Acc.                 Yalut     Range       Range         Range           Comments Speed (N)                 NA               NA           NA             NA                       NA         NA           NA           NA               Constant speed driver inlet Pressure           Qtr               PI-22410     0-30           12%                       NA       NA           NA           NA               NA (Pi)                                               psig Outlet Pressure           Qtr               PI-22414     0-200           12%                       NA       NA           NA           NA               NA                 i (Po)                                               psig Differ.
O O
Pressure           Qtr               NA(1)         NA             12%                       APr       .90 - 1.10APr NA           <.90 or >l.10APr NA (AP)
Test Parameter Table - Pump 2-1592-P7-001 (Figure ISI-D-275)
Flowrate           Qtr               F1-22425     0-750           12%                       Qr       NA           NA           NA               Flowrate is set at reference value (Q)                                               gpm Vib.
Instrumentation Utilized Ref.
Amp.               Qtr               (2)           NA             iS%                       Vr       5 2.5Vr       > 2.5Vr - 6Vr >6Vr or         NA (V)(4)                                                                                                               or >.325 in/s >.70 in/s Notes:
Acceptable Alert Action Parameter Test Frea.
1.D. NoJ3)
Range Rea. Acc.
Yalut Range Range Range Comments Speed (N)
NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-22410 0-30 12%
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-22414 0-200 12%
NA NA NA NA NA i
(Po) psig Differ.
Pressure Qtr NA(1)
NA 12%
APr
.90 - 1.10APr NA
<.90 or >l.10APr NA (AP)
Flowrate Qtr F1-22425 0-750 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib.
Amp.
Qtr (2)
NA iS%
Vr 5 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA (V)(4) or >.325 in/s
>.70 in/s Notes:
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.
23 - 2                                                 Rev.O
23 - 2 Rev.O


O                                                                                               O                                                                                   O Test Parameter Table .- Pump 2-1592-P7-002                                                                                                         .
O O
(Figure ISI-D-276)                                                                                                               ,
O Test Parameter Table.- Pump 2-1592-P7-002 (Figure ISI-D-276)
Instrumentatian Utili=d       Ref.             Acceptable           Alert         Action I.D. No.f3) Range         Req. As Value             Range                 Range         Range               Comments                                                     ;
Instrumentatian Utili=d Ref.
Parameter                                                                Iest Frea.
Acceptable Alert Action Parameter Iest Frea.
Speed NA         NA           NA           NA         NA               NA                   NA           NA                 Constant speed driver                                         .
I.D. No.f3)
(N)
Range Req. As Value Range Range Range Comments Speed (N)
Inlet                                                                                                                                                                                                                                                           '
NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-22411 0-30 12%
Pressure                                                                 Qtr       PI-22411     0-30         12%       NA               NA                   NA           NA                 NA (Pi)                                                                                             psig Outlet                                                                                                                                                                                                                                                         ;
NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-22415 0-200 12%
PI-22415     0-200       12%       NA               NA                   NA           NA                 NA Pressure                                                                  Qtr (Po)                                                                                             psig Differ.
NA NA NA NA NA (Po) psig Differ.
Pressure                                                                 Qtr       NA(1)       NA           i2%       APr             .90 - 1.10APr         NA           <.90 or >l.10APr -' NA (AP)
Pressure Qtr NA(1)
Flowrate                                                                 Qtr       FI-22426     0-750       12%       Qr               NA                   NA           NA                 Flowrate is set at reference value (Q)                                                                                               gpm
NA i2%
        ' Vib.                                                                                                                                                                                                                                                           I Amp.                                                                     Qtr       (2)         NA           i5%'       Vr               s 2.5Vr               > 2.5Vr - 6Vr >6Vr or             NA or >.325 in/s >.70 in/s                                                                       ;
APr
(V)(4) i Notes:
.90 - 1.10APr NA
<.90 or >l.10APr -' NA (AP)
Flowrate Qtr FI-22426 0-750 12%
Qr NA NA NA Flowrate is set at reference value (Q) gpm
' Vib.
I Amp.
Qtr (2)
NA i5%'
Vr s 2.5Vr
> 2.5Vr - 6Vr
>6Vr or NA or >.325 in/s
>.70 in/s (V)(4) i Notes:
[
[
: 1. Differential pressure is calculated as, AP = Po - Pi
: 1. Differential pressure is calculated as, AP = Po - Pi
: 2. Portable vibration instruments are utilized.
: 2. Portable vibration instruments are utilized.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial                                                                                   !
: 4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial
            ' direction on each accessible thrust bearing housing.                                                                                                                                                                                                       !
' direction on each accessible thrust bearing housing.
l i
l i
                                                                                                                                                                                                                                                                        }
}
23 - 3                                                                 Rev.0                                       [
23 - 3 Rev.0
[
t
t


O                                                                         O                                                                                                                                           O NOTE: 1. THIS IS A SIMPLIFIED EXPANSION                                                                                                                                                                 DIAGRAM USED TO DEPICT TANK HVC                                                                                                                  A TEST CIRCUIT. REFER S     2-1592-T7-001                                                                                                                                                               TO THE Pt.ID FOR 2240                                                   P2412                                                                                                                         DETAILS.
O O
C 2240                             1,                                       (                                                                                                                         2. VALVE INTERNALS REMOVED PER DCP IhA D                                      90-V2N0068-0-1 f                                 CHEMICAL                                                   SDA                                                                               TI     FI
O NOTE: 1. THIS IS A SIMPLIFIED EXPANSION DIAGRAM USED TO DEPICT TANK A TEST CIRCUIT. REFER HVC S
                                                                        "'        FEED PDT.
2-1592-T7-001 TO THE Pt.ID FOR 2240 P2412 DETAILS.
D 242 m p ,.@          @
C 2240 1,
t'' 9                                                                                     02 PI     TI                             22 1                                                 1 P     44 2241 22410 5032                                                                                   9 L N,                                                                                                                                               1/2' C                   fl                     N           6*X4'                                                                                                                                         !!
(
N                'sm             dEVAP.l E                         @CB ESF CHILLER EMERGENCY MAKEUP VATER g*       I                2'  6' I/2' 2-1592-C 7-001-000 m,
: 2. VALVE INTERNALS REMOVED PER DCP IhA 90-V2N0068-0-1 D
Ci r                           5030 EC'                                   HV       Sd k 240 CB ESF CHILLED                                                                                                                               242 fl 10'                               VATER PUMP                                                                                                                                                 I f Y       2-1592-P7-001-000 (10*      10'%                D         PROJ. CLASS 313 E'                       _                                                                                                    TRAIN 'A'                                     6'
f CHEMICAL SDA TI FI FEED PDT.
                                                                            ~
242 D
m p,.
t'' 9 02 PI TI 22 1 1 P 44 2241 22410 5032 9 L N,
1/2' C
fl N
6*X4' N
'sm dEVAP.l E
@CB ESF CHILLER EMERGENCY I/2' MAKEUP VATER g*
2-1592-C 7-001-000 I
2' 6'
Ci r 5030 m,
EC' HV Sd k fl 240 CB ESF CHILLED 242 10' VATER PUMP I f (10*
10'%
Y 2-1592-P7-001-000 D
PROJ. CLASS 313 E'
TRAIN
'A' 6'
~
COOLING COILS
COOLING COILS
  =v. mm     e, o.,                       =_.                 -      -,            m.
=v.
                                                                                  .      m. _.
mm e,
9     WS-te M   vs     133E3 FtB PIT                           *]
o.,
:    se-as ca. ets   woms is eva er enma                   -_C bS E E           C .1" b                                 Southern Company Services, Inc. FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT smeen n                                                                                             mm. =
=_.
UNIT 2                                                   =                                   === vs
m.
                                                                                                                                                                                                              ~
m.
PUMP INSERVICE TESTING LOOP                                                                                           -a        "EC'           x,   o FOR CB ESF CHILLED VATER PUMP TRAIN 'A'                           2-1592-P7-001-000                                         N/A                       N/A   ISI-D- 275   1 IT I 3
9 WS-te M
vs 133E3 FtB PIT
*]
se-as ca.
ets woms is eva er enma
-_C bS E E C.1" b
Southern Company Services, Inc. FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT smeen n mm.
=
UNIT 2
=
 
=== vs PUMP INSERVICE TESTING LOOP "EC' x,
~
-a o
FOR CB ESF CHILLED VATER PUMP TRAIN
'A' 2-1592-P7-001-000 N/A N/A ISI-D-275 1 IT I 3


O                                                                                                       O                                                                                                                                                                                                                               O NOTE 1. THIS IS A SIMPLIFIED EXPANSION                                                                                                                                                                                                                                                           DIAGRAM USED TO DEPICT TANK C                                                                                                                                                                                A TEST CIRCUIT. REFER S           2-1592-T7-00E                                                                                                                                                                                                                                                         TO THE P&lD FOR 2240                                                                                     2413                                                                                                                                                                                         DETAILS.
O O
C                                                                                                                                                                                                                                                                                                 2. VALVE INTERNALS I,
O NOTE
22401                                                                                                                                                                                                                                                                                                      REMOVED PER DCP IA                                                                                                                           90-V2N0068-0-1 j                                                                                                                                  pD CHEMICAL                                                   SDB                                                                                                                                                                       TI       FI 7'
: 1. THIS IS A SIMPLIFIED EXPANSION DIAGRAM USED TO DEPICT TANK A TEST CIRCUIT. REFER C
D                                      FEED POT.                                                                                                                                                                                                                           243       4 shmn,.                                                                                                                                                 t'' 9                                                                                                                   De (U57)                      g                                                                                                                              PI                           g                                    HV                       TI                                                                                 243 '     2441 pg 22411 b                                                                             $d L
S 2-1592-T7-00E TO THE P&lD FOR 2240 2413 DETAILS.
                                              @ 3,                                                                                                                                                               1/2" 6'
C
lpp_{)g}                   _
: 2. VALVE INTERNALS 22401 I,
d EVAP. l N CB ESF CHILLER K          ATER                            O'                                   2'    6'            c O5 1                                                                                                          -                                                -
REMOVED PER DCP IA j
                                                                                                                                                                                                                                                                                                                                                  -002-000
90-V2N0068-0-1 pD CHEMICAL SDB TI FI D
                                                ''       l mir LC'                                             [HV       $d k           CB ESF CHILLED                                                                                                                                                                                                                   242 fl             2240                       VATER PUMP 10'                                 2-1592-P7-002-000                                                                                                                                                                                                                                 I I 10'     10'                                 PROJ. CLASS 313 b'                         _                                                                                        TRAIN 'B'                                                                                                                                         6'                       ;
FEED POT.
                                                                                                        ~
243 4
CDOLING COILS av. an         r,                 o.c,                       er _ . .,,.
7' shmn,.
i u -,        2       .    .                            .
t'' 9 De PI HV TI 243 '
9     W       BE                   WS     1EstKB f1R PtY                                         I s-as-ee   et                 us a                                          trairra in svm er asesora                           - JC s    'Ae-                   M "w2 "'E ~ '                                                                                         Southern Company Services, Inc. FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT                                                                                                 8m"*                                         "                                      " '''
2441 (U57) g pg g
UNIT 2                                                                                       "                                                                                  ""*v5 PUMP INSERVICE TESTING LOOP                                                                                                                               " ,,aa.                                     527             x,   .
22411 b
FOR CB ESF CHILLED VATER PUMP TRAIN 'B'             2-1592-P7-002-000                                                                                 N/A                                                                   N/A   ISI-D- 276   1 [F 1 3
$d L
@ 3, 1/2" 6'
lpp_{)g} _
d EVAP. l N
O CB ESF CHILLER O'
-002-000 K
ATER l
2' 6'
c 5 1 mir LC'
[HV
$d k CB ESF CHILLED 242 fl 2240 VATER PUMP 10' I I 2-1592-P7-002-000 10' 10' PROJ. CLASS 313 b'
TRAIN
'B' 6'
~
CDOLING COILS i
av.
an r,
o.c, er _..,,.
u 2
9 W
BE WS 1EstKB f1R PtY I
a s-as-ee et us trairra in svm er asesora
- JC
'Ae-M "w2 "'E ~ '
Southern Company Services, Inc. FOR Southern Nuclear Operating Company s
VDGTLE ELECTRIC GENERATING PLANT 8m"*
UNIT 2
""*v5 PUMP INSERVICE TESTING LOOP
",,aa.
527 x,
FOR CB ESF CHILLED VATER PUMP TRAIN
'B' 2-1592-P7-002-000 N/A N/A ISI-D-276 1 [F 1 3


PUMP RELIEF REQUEST LOG Relief Reauest Number         Status RR-P-1                       Submitted for NRC Review.
PUMP RELIEF REQUEST LOG Relief Reauest Number Status RR-P-1 Submitted for NRC Review.
RR-P-2.                       Submitted for NRC Review.
RR-P-2.
RR-G-1                       Submitted for NRC Review.
Submitted for NRC Review.
RR-G-2                       Submitted for NRC Review.
RR-G-1 Submitted for NRC Review.
RR-G-2 Submitted for NRC Review.
i t
i t
O O
O O
24-1                       Rev.0
24-1 Rev.0
                                              .                =
=


PUMP RELIEF REQUEST RR-P-1 2
PUMP RELIEF REQUEST RR-P-1 2
SYSTEM:
SYSTEM:
Chemical Volume and Control System (CVCS)
Chemical Volume and Control System (CVCS)
PUMPS:             Boric Acid Transfer i
PUMPS:
s                                1-1208-P6-006 and -007 and 2-1208-P6-006 and -007 l           CLASS:             3 i                                                                                                          )
Boric Acid Transfer i
TEST                                                                                         I
1-1208-P6-006 and -007 and 2-1208-P6-006 and -007 s
!            REQUIREMENT.                                                                                 i j                               ISTB 4.7.1(b)(1) requires the full scale range of analog instmments to be l i
l CLASS:
not greater than three times the reference value.
3
l j           BASIS FOR RELIEF:                                                                             i Suction pressure gages PI-10115 and PI-10116 have a full scale range ol
)
[                               30 inches of mercury to 15 psig, or -15 psig to 15 psig with an accuracy l i                              ofi0.15 psig. Since pressure readings when the pump is running will i
i TEST REQUIREMENT.
l                               always be positive, the range ofinterest for IST is 0 - 15 psig. The       l j                               actual suction pressure experienced during surveillance testing is         '
j ISTB 4.7.1(b)(1) requires the full scale range of analog instmments to be not greater than three times the reference value.
;                              approximately 2 psig which results in a maximum allowable range of 0 -
i j
6 psig to satisfy the Code requirements. The Code allowable tolerance l                                                                                                         j j                              would be 10.12 psig (0.02 x 6). Since the only purpose for measuring i
BASIS FOR RELIEF:
suction pressure is to use in determining differmtial pressure, for t
Suction pressure gages PI-10115 and PI-10116 have a full scale range o i
comparison to the test reference value, a total difference of 0.03 (0.15 - '
[
0.12) psig in the measurement of differential pressure will have no impact on the repeatability or adequacy of the pump test. Therefore, the
30 inches of mercury to 15 psig, or -15 psig to 15 psig with an accuracy ofi0.15 psig. Since pressure readings when the pump is running will i
i l
always be positive, the range ofinterest for IST is 0 - 15 psig.The j
actual suction pressure experienced during surveillance testing is approximately 2 psig which results in a maximum allowable range of 0 -
l; 6 psig to satisfy the Code requirements. The Code allowable tolerance l
j would be 10.12 psig (0.02 x 6). Since the only purpose for measuring j
i suction pressure is to use in determining differmtial pressure, for comparison to the test reference value, a total difference of 0.03 (0.15 -
t 0.12) psig in the measurement of differential pressure will have no impact on the repeatability or adequacy of the pump test. Therefore, the
{
{
existing suction pressure gages provide adequate means for measuring j                              the pump suction pressure and do not jeopardize the adequacy of the testing being performed.
existing suction pressure gages provide adequate means for measuring the pump suction pressure and do not jeopardize the adequacy of the j
1       ALTERNATE i
testing being performed.
TESTING:                                                                                         )
1 ALTERNATE i
None. The existing suction pressure gages will be utilized for IST of the   !
)
referenced pumps.
TESTING:
None. The existing suction pressure gages will be utilized for IST of the referenced pumps.
l l
l l
l l
O i
l I
24-2 Rev.O 1
l O
1
i 24-2                                   Rev.O           i l
1 1


~
~
,                                                                PUMP RELIEF REQUEST RR-P-2
PUMP RELIEF REQUEST RR-P-2 SYSTEM-Allincluded in scope ofIST Program PUMPS:
;            SYSTEM-Allincluded in scope ofIST Program PUMPS:
j Allincluded in scope ofIST Program CLASS:
j                                               Allincluded in scope ofIST Program
2 and 3 I
,            CLASS:                             2 and 3 I
TEST REQUIREMENT:
TEST
ISTB 6.1 - If deviations fall within the required action range of Table l
:          REQUIREMENT:
ISTB 5.2-1, the pump shall be declared inoperable until the cause of the deviation has been determined and the condition corrected 2
!                                              ISTB 6.1 - If deviations fall within the required action range of Table ISTB 5.2-1, the pump shall be declared inoperable until the cause of the l
BASIS FOR RELIEF:
2 deviation has been determined and the condition corrected BASIS FOR RELIEF:
The ASME Section XI Code,1989 Edition, subsection IWP-3230(c) states that;
The ASME Section XI Code,1989 Edition, subsection IWP-3230(c) states that;
!                                              " Corrective action shall be either replacement or repair per IWP-3111, or i                                              shall be an analysis to demonstrate that the condition does not impair i
" Corrective action shall be either replacement or repair per IWP-3111, or shall be an analysis to demonstrate that the condition does not impair i
pump operability and that the pump will still fulfill its function. A new 4
i pump operability and that the pump will still fulfill its function. A new set of reference values shall be established after such analysis."
set of reference values shall be established after such analysis."
4 l
l                                             The both 6.2.2)      OMc-1994 state that;    Addenda (ISTB 6.2.2) and the OM 1995 ed i
The OMc-1994 Addenda (ISTB 6.2.2) and the OM 1995 ed 6.2.2) both state that; i{(
{(
"If the measured test parameter values fall within the required action I_
;                                            "If the measured test parameter values fall within the required action I_                                           range of Table 5.2.1-1, Table 5.2.1-2, Table 5.2.2-1, or Table 5.2.3-1, as i                                            applicable, the pump shall be declared inoperable until either the cause of
range of Table 5.2.1-1, Table 5.2.1-2, Table 5.2.2-1, or Table 5.2.3-1, as applicable, the pump shall be declared inoperable until either the cause of i
!                                            the deviation has been determined and the condition corrected, or an l
the deviation has been determined and the condition corrected, or an l
analysis of the pump is performed and new reference values are l
analysis of the pump is performed and new reference values are established in accordance with ISTB 4.6."
1                                            established in accordance with ISTB 4.6."                                             l l                                             The Code applicable for the first intervalIST Program (1983 ASME XI),
l 1
and the latest issued Code both provide for analysis of pump test data in i
l The Code applicable for the first intervalIST Program (1983 ASME XI),
lieu of repair or replacement of the pump if the test parameters fall within 4                                                                                                                                   !
i and the latest issued Code both provide for analysis of pump test data in lieu of repair or replacement of the pump if the test parameters fall within 4
the required action range. The OM Code-1990 Edition did not include such provisions.                                                                       !
the required action range. The OM Code-1990 Edition did not include such provisions.
Communications with members of the OM Code Committee indicate that this was an oversight and that it was never intended to delete the ability to analyze the test data and determine if the i
Communications with members of the OM Code Committee indicate that this was an oversight and that it was never intended to delete the ability to analyze the test data and determine if the i
pump is still capable of performing its intended safety function.
pump is still capable of performing its intended safety function.
4 ALTERNATE TESTING:
ALTERNATE 4
Should pump test parameters fall within the required action range of Table ISTB 5.2-2 (OM Code 1990 Edition), then the OM Code 1995 Edition, subsection ISTB 6.2.2 will be utilized. Since subsection ISTB 4.6 in the 1995 Code Edition references ISTB 6.2.2, subsection ISTB                     4 4.6 from the OM Code 1995 Edition will also be applied.
TESTING:
L 24-3                               Rev.O
Should pump test parameters fall within the required action range of Table ISTB 5.2-2 (OM Code 1990 Edition), then the OM Code 1995 Edition, subsection ISTB 6.2.2 will be utilized. Since subsection ISTB 4.6 in the 1995 Code Edition references ISTB 6.2.2, subsection ISTB 4
4.6 from the OM Code 1995 Edition will also be applied.
L 24-3 Rev.O


GENERAL RELIEF REQUEST p
GENERAL RELIEF REQUEST py RR-G-1 SYSTEMS: Allin Scope ofIST Program VALVES:
y                                                    RR-G-1 SYSTEMS: Allin Scope ofIST Program VALVES:     Allin Scope ofIST Program                                                                     I PUMPS:     Allin Scope 7 FIST Program CLASS:     1,2 and 3 TEST REQUIREMENT: The version of 10CFR50 in effect on May 31,1996, paragraph 50.55a(b)(2)                     )
Allin Scope ofIST Program I
specifies the applicable Code to be the ASME XI,1988 Addenda through 1989           )
PUMPS:
Allin Scope 7 FIST Program CLASS:
1,2 and 3 TEST REQUIREMENT: The version of 10CFR50 in effect on May 31,1996, paragraph 50.55a(b)(2)
)
specifies the applicable Code to be the ASME XI,1988 Addenda through 1989
)
Edition. The 1989 Edition of ASME XI references OM part 6 and 10 for
Edition. The 1989 Edition of ASME XI references OM part 6 and 10 for
                                                                                                                    ~
~
inservice pump and valve testing respectfully. Paragraph 50.55a(b)(2)(viii) of the CFR specifies the Code applicable to inservice pump and valve testing to be the ASME/ ANSI part 6 and ASME/ ANSI part 10 of the OMa-1988 Addenda to the OM-1987 Edition.
inservice pump and valve testing respectfully. Paragraph 50.55a(b)(2)(viii) of the CFR specifies the Code applicable to inservice pump and valve testing to be the ASME/ ANSI part 6 and ASME/ ANSI part 10 of the OMa-1988 Addenda to the OM-1987 Edition.
BASIS FOR                                                                                                 4 RELIEF:               The ASME/ ANSI OM document was issued as a Code with the ASME OM                   !
BASIS FOR 4
Code-1990 Edition. This edition was amended with the OMa Code-1991                 l Addenda, the OMb Code-1992 Addenda, and the OMc Code-1994 Addenda.                 '
RELIEF:
The ASME OM Code-1995 Edition was issued in early 1995. With each addenda and edition of the ASME OM Code, the ASME OM Code Committee pg                         has included updated inservice testing requirements based on improved V                           knowledge, operating history and experience and changes in testing technology.     ,
The ASME/ ANSI OM document was issued as a Code with the ASME OM Code-1990 Edition. This edition was amended with the OMa Code-1991 Addenda, the OMb Code-1992 Addenda, and the OMc Code-1994 Addenda.
Beginning with the ASME OM Code-1990 Edition, the format of the document           !
The ASME OM Code-1995 Edition was issued in early 1995. With each addenda and edition of the ASME OM Code, the ASME OM Code Committee pg has included updated inservice testing requirements based on improved V
was also changed to read like a Code instead of a standard as it was initially drafted. Therefore, application oflater versions of the ASME OM Code, than specified in 10CFR50, should enhance the quality of the IST Program.               i ALTERNATE TESTING:             The ASME OM Codes utilized for update of the Vogtle Inservice Testing Program shall be:
knowledge, operating history and experience and changes in testing technology.
Beginning with the ASME OM Code-1990 Edition, the format of the document was also changed to read like a Code instead of a standard as it was initially drafted. Therefore, application oflater versions of the ASME OM Code, than specified in 10CFR50, should enhance the quality of the IST Program.
i ALTERNATE TESTING:
The ASME OM Codes utilized for update of the Vogtle Inservice Testing Program shall be:
IST of Valves (except safety / relief valves)- ASME OM Code-1990 Edition IST of Pumps - ASME OM Code-1990 Edition IST of Safety / Relief Valves - ASME OM Code 1995 Edition (ASME OM Code-1995 Edition, Appendix I, augments the rules of Stabsection ISTC 4.4.)
IST of Valves (except safety / relief valves)- ASME OM Code-1990 Edition IST of Pumps - ASME OM Code-1990 Edition IST of Safety / Relief Valves - ASME OM Code 1995 Edition (ASME OM Code-1995 Edition, Appendix I, augments the rules of Stabsection ISTC 4.4.)
The NRC previously approved use of the above referenced Codes in a {{letter dated|date=November 27, 1996|text=letter dated November 27,1996}}. This relief request is identical to RR-G-1 included in the IST Valve Program.
The NRC previously approved use of the above referenced Codes in a {{letter dated|date=November 27, 1996|text=letter dated November 27,1996}}. This relief request is identical to RR-G-1 included in the IST Valve Program.
yQ F
Q y
24-4                                         Rev. O
F 24-4 Rev.
O


l GENERAL RELIEF REQUEST RR-G-2                                                   <
l GENERAL RELIEF REQUEST RR-G-2 l
l SYSTEMS: Allin Scope of Unit 2 IST Program VALVES:     Allin Scope of Unit 2 IST Program PUMPS:     Allin Scope of Unit 2 IST Program CLASS:     1,2 and 3 TEST                                                                                                     1 REQUIREMENT: The version of 10CFR50 in effect on May 31,1996, paragraph 50.55a(f)(4)(ii),
SYSTEMS: Allin Scope of Unit 2 IST Program VALVES:
Allin Scope of Unit 2 IST Program PUMPS:
Allin Scope of Unit 2 IST Program CLASS:
1,2 and 3 TEST 1
REQUIREMENT: The version of 10CFR50 in effect on May 31,1996, paragraph 50.55a(f)(4)(ii),
specifies that inservice testing to verify operational readiness of pumps and valves required for. safety, conducted during successive 120-month intervals must comply with the requirements of the latest edition and addenda of the Code incorporated by reference in paragraph 10CFR50.55a(b) 12 months prior to the start of the 120-month interval.
specifies that inservice testing to verify operational readiness of pumps and valves required for. safety, conducted during successive 120-month intervals must comply with the requirements of the latest edition and addenda of the Code incorporated by reference in paragraph 10CFR50.55a(b) 12 months prior to the start of the 120-month interval.
BASIS FOR RELIEF:             The commercial operation date for Vogtle Unit I was May 31,1987. The commercial operation date for Vogtle Unit 2 was May 20,1989. Maintaining both units on the same interval schedule allows both IST programs to be developed utilizing the same edition of the applicable Codes, will make it easier for involved personnel to become familiar with the Code requirements, will ensure a greater degree of consistency for IST between the units, and will O-                      reduce the cost associated with surveillance arocedure revisions for the program update and for maintenance of the program c ocuments.
BASIS FOR RELIEF:
The commercial operation date for Vogtle Unit I was May 31,1987. The commercial operation date for Vogtle Unit 2 was May 20,1989. Maintaining both units on the same interval schedule allows both IST programs to be developed utilizing the same edition of the applicable Codes, will make it easier for involved personnel to become familiar with the Code requirements, will O-ensure a greater degree of consistency for IST between the units, and will reduce the cost associated with surveillance arocedure revisions for the program update and for maintenance of the program c ocuments.
ALTERNATE.
ALTERNATE.
TESTING:             Update the Vogtle Nuclear Plant Unit 2 IST Program concurrent with the Unit I second 10-year interval IST Program update due on May 31,1997. The Unit 2 IST Program will be updated concurrent with the Unit 1 IST Program in accordance with the applicable regulations for the remainder of the plant life.
TESTING:
Update the Vogtle Nuclear Plant Unit 2 IST Program concurrent with the Unit I second 10-year interval IST Program update due on May 31,1997. The Unit 2 IST Program will be updated concurrent with the Unit 1 IST Program in accordance with the applicable regulations for the remainder of the plant life.
The NRC previously approved use of the above referenced Codes in a {{letter dated|date=November 27, 1996|text=letter dated November 27,1996}}. This relief request is identical to RR-G-1 included in the IST Valve Program.
The NRC previously approved use of the above referenced Codes in a {{letter dated|date=November 27, 1996|text=letter dated November 27,1996}}. This relief request is identical to RR-G-1 included in the IST Valve Program.
i 4
i 4
1 i
i O
O                                                                                                           l l
4 24-5 Rev.
4 24-5                                         Rev. O   i
O i
-                              -                                                                            1}}
1}}

Latest revision as of 11:54, 11 December 2024

Rev 0 to VEGP Units 1 & 2 Second 10-Yr Interval Pump IST Program
ML20148E648
Person / Time
Site: Vogtle  
Issue date: 05/15/1997
From:
SOUTHERN NUCLEAR OPERATING CO.
To:
Shared Package
ML20148E642 List:
References
PROC-970515, NUDOCS 9706030209
Download: ML20148E648 (180)


Text

{{#Wiki_filter:, o<r N' VOGTLE ELECTRIC GENERATING PLANT UNITS 1 & 2 SECOND 10 -YEAR INTERVAL PUMP INSERVICE TEST PROGRAM R ITS ITS ITS VNMS E DATE DESCRIPTION PREP'D REV'D APPV'D APPV'D V BY BY BY BY 0 12/06/96 INITIAL ISSUE TO VEGP FOR REVIEW & APPROVAL. VEGP IST APPROVAL IST Eng J -- 'I 6/co/e-l Engr. Supv: / 104tre 97-97 Mgr. Engr: [ 4%d .5 'M/ 2 ANQ: 'd pf{w JhGX phA ZfErg, _ J 9 7 PRB: Mtg. No: Mb9 30 JA Date: ,5lsMg j' [ / I' / Gen. Mgr: C,, O [$ 7 t l / 9706030209 970529 PDR ADOCK 05000424 P PDR Vogtle Electric Generating Plant Route 2, Box 299-A Waynesboro, GA 30830

  • ) ' 10\\

DISTRIBUTION LIST l IIOLDER MANUAL NUMBER K. G. Lowery (SCS) 1 1 T. M. Hickox 2 J. J. Churchwell 3 SNC Site Document Control Supervisor 4 SNC Site Perfbrmance Supervisor 5 i K. L. Glandon 6 J. C. McWimrter 7 ITS Department Shelf Copy 8 O l Rev.O

TABLE OF CONTENTS (See Active Page List for Current Revision) O SECTION PAGES PROGRAM INTRODUCTION 1-1 thm 1-2 ABBREVIATIONS LIST 2-1 thm 2-2 PUMP INTRODUCTION 3-1 thm 3-9 VEGP 1 PUMP TABLES 4-1 thm 4-8 ] NSCW PUMPS 5-1 thm 5-10 NSCW PUMP TEST DIAGRAMS 8 pages l CCW PUMPS 6-1 thm 6-7 CCW PUMP TEST DIAGRAMS A pages S1 PUMPS 7-1 thm 7-3 S1 PUMP TEST DIAGRAMS 2 pages RHR PUMPS 8-1 thm 8-3 RHR PUMP TEST DIAGRAMS 2 pages CS PUMPS 9-1 thm 9-3 CS PUMP TEST DIAGRAMS 2 pages CVCS PUMPS 10-1 thm 10-3 CVCS PUMP TEST DIAGRAMS 2 pages BAT PUMPS 11-1 thm 11-3 BAT PUMP TEST DI AGRAMS 2 pages AFW PUMPS 12-1 thru 12-6 AFW PUMP TEST DIAGRAMS 3 pages ESF PUMPS 13-1 thru 13-3 ESF PUMP TEST DIAGRAMS 2 pages VEGP-2 PUMP TABLES 14-1 thru 14-8 NSCW PUMPS 15-1 thm 15-10 NSCW PUMP TEST DIAGRAMS 8 pages CCW PUMPS 16-1 thru 16-7 CCW PUMP TEST DIAGRAMS 6 pages Page1of2

Table of Contents (cont.) S1 PUMPS 17-1 thru 17-3 SI PUMP TEST DIAGRAMS 2 pages RHR PUMPS 18-1 thm 18-3 RHR PUMP TEST DIAGRAMS 2 pages 1 CS PUMPS 19-1 thru 19-3 CS PUMP TEST DIAGRAMS 2 pages CVCS PUMPS 20-1 thru 20-3 CVCS PUMP TEST DIAGRAMS 2 pages BAT PUMPS 21-1 thru 21-3 BAT PUMP TEST DIAGRAMS 2 pages AFW PUMPS 22-1 thm 22-6 AFW PUMP TEST DIAGRAMS 3 pages ESF PUMPS 23-1 thru 23-3 i ESF PUMP TEST DIAGRAMS 2 pages RELIEF REQUESTS 24-1 thru 24-5 Ob l O L) Page 2 of 2

1 ACTIVF PAGE LIST Pane No. Rev. No. Page No. Rev. No. ('( )s 1-1 0 6-6 0 l-2 0 6-7 0 2-1 0 ISI-D-209 2 2-2 0 ISI-D-210 2 3-1 0 ISI-D-211 2 3-2 0 ISI-D-212 2 3-3 0 ISI-D-213 2 3-4 0 ISI-D-214 2 3-5 0 7-1 0 3-6 0 7-2 0 3-7 0 7-3 0 3-8 0 ISI-D-215 3 3-9 0 ISI-D-216 3 4-1 0 8-1 0 4-2 0 8-2 0 4-3 0 8-3 0 4-4 0 ISI-D-217 6 4-5 0 ISI-D-218 6 4-6 0 9-1 0 4-7 0 9-2 0 4-8 0 9-3 0 (j 5-1 0 ISI-D-219 3 5't 0 ISI-D-220 3 5-3 0 10 - 1 0 5-4 0 10 - 2 0 5-5 0 10 -3 0 5-6 0 ISI-D-221 5 5 0 ISI-D-222 5 5-8 0 11-1 0 5-9 0 11 - 2 0 5 - 10 0 11 - 3 0 ISI-D-201 2 ISI-D-228 3 ISI-D-202 2 ISI-D-229 3 ISI-D-203 2 12-1 0 ISI-D-204 2 12-2 0 ISI-D-205 2 12-3 0 ISI-D-206 2 12-4 0 ISI-D-207 3 12-5 0 ISI-D-208 3 12-6 0 6-1 0 ISI-D-223 2 6-2 0 ISI-D-224 2 6-3 0 ISI-D-225 2 (]s 6-4 0 13 - 1 0 6-5 0 13 - 2 0 Page 1 of 2 Updated 04/28/97

....___..._..____.-.__....__.__._.____._.._m t - Pane No.- Rev No. Page No. Rev.No. P 13 - 3 0 17-4 0 ISI-D-226 3 ISI-D-264 2 i ISI-D-227 3 ISI-D-265 2 i 14 - 1 0 18 - 1 0 14'- 2 0 18 - 2 0 14 - 3 0 18 - 3 0 l . 14-4 0 18 -4 0 2 14 0 ISI-D-266 3-14 - 6 0 ISI-D-267 3 4 14 - 7 0. 19 - 1 0 0 ' 14-8 0 19 - 2 0 i 15 - 1 0 19 -3 0 j-15 - 2 0 ISI-D-268 4 ] 15 - 3 0 ISI-D-269 4 15 - 4 0 20 - 1 0 15 - f 0 20 - 2 0 2 1 i 15 - 6 0 20 -3 0 15 - 7 0 ISI-D-270 5 15 - 9. O ISI-D-271 2 15 - 8 0 21 - 1 0 i 15 - 10 0 21 - 2 0 l ISI-D-250 5 21 - 3 0 ISI-D-251 ' 2 ISI-D-277 2 I ISI-D-252 2 ISI-D-278 2 ISI-D-253 2 22 - 1 0 ISI-D-254 2 22 - 2 0 ISI-D-255 2 22 - 3 0 ISI-D-256 2 22 - 4 0 ISI-D-257 3 22 - 5 0 16.1 0 22 - 6 0 16 - 2 0 ISI-D-272 2 l 16 - 3 0 ISI-D-273 2 16 - 4 0 ISI-D-274 2 16 - 5 0 23 - 1 0 16 - 6 0 23 - 2 0 16 - 7 0 23 -3 0 ISI-D-258 2 ISI-D-275 3 ISI-D-259 2 ISI-D-276 3 ISI-D-260 2 24 - 1 0 ISI-D-261 2 24 - 2 0 ISI-D-262 2 24 - 3 0 ISI-D-263 2 24 - 4 0 17-1 0 24 - 5 0 17 - 2 0 17 - 3 0 Page 2 of 2 Updated 04/28/97

1.0 PUMP IST PROGRAM INTRODUCTION 1.1 GENERAL

q

'( / This document describes the Pump Inservice Testing (IST) Program for the Vogtle Electric v j Generating Plant (VEGP), Units 1 and 2. Provided below are important dates relative to the IST l Program. VEGP-1 VEGP-2 4 Construction Permit: 06-28-74 06-28-74 j Commercial Operation: 05-31-87 05-20-89 1st 10-Year Interval: 05-31-87 to 05-20-89 to 05-30-97 05-30-97* i 2nd 10-Year Interval: 05-31-97 to 05-31-97* to 05-30-2007 05-30-2007 VEGP-2 was updated at the same time as VEGP-1 for the 2nd 10-Year Interval in order to t utilize the same Code edition for both units (See Relief Request RR-G-2 which is included in the Valve IST Program document). 4 O' The edition of 10 CFR 50.55a current on May 31,1996, was used to determine the applicable Code (s) of record for this program update. 10 CFR 50.55a identified the ASME Section XI Code, 1989 Edition, as the applicable Code. The 1989 edition of ASME XI references OM Part 6 (IWP) as being applicable for pump testing. 10 CFR 50.55a(b)(2)(viii) references the OMa-1988 Addenda to the OM-1987 Edition of ANSI /ASME part 6 for pump testing. ASME issued the OM Code-1990 Edition which included requirements for pump, valve, relief valve and dynamic restraint inservice testing, and subsequently issued the OMb-1992 Addenda, the OMc-1994 Addenda, the OM-1995 Edition and the OMa-1996 Addenda. Therefore, the below listed Code version is being utilized for pump IST at VEGP as described in Relief Request RR-G-

1. (RR-G-1 is included in the Valve IST Program document.) The NRC approved the use of the 1

ASME OM Code-1990 Edition for pump testing at Plant Vogtle in a letter dated November 27, i 1996. ASME OM Code -1990 Edition Subsections ISTA and ISTB This program document includes IST requirements for safety.related ASME Code Class 1,2 and 3 pumps. NRC Generic Letter 89-04 and Supplement 1 (NRC NUREG-1482) were used, to the extent practical, for guidance in the development of this program. 1.2 EFFECTIVE DATE The Pump IST Program, for the 2nd 10-Year Interval, will become effective on May 31,1997 and will be utilized through May 30,2007 unless federal regulations are revised otherwise. 1-1 Rev.0

~ 1.3 SCOPE This document is a description of the Pump IST Program to be implemented for Units 1 and 2 at i VEGP. This document describes only the IST surveillance testing applicable to safety-related ASME Code Class 1,2 and 3 punips included in the program. w A 1.4 SUBSEQUENT PROGRAM REVISIONS It is anticipated that this document will be reviewed again near the end of the 120 month interval and compared to a later NRC approved version of the ASME Code applicable for IST. At that time, the program will be modified, if required, to comply to the extent practical with the later 3 Code edition. Any additional relief requests for impractical requirements will be submitted in accordance with the applicable regulations. 4 1.5 RESPONSIBILITY { Southern Nuclear Operating Company, being license holder and agent for Georgia Power Company (Owner), bears the overall responsibility for the implementation of the inservice testing activities j contained in this program per the ASME OM Code - 1990 Edition, Subsection ISTA 1.4. l l 1.6 RECORDS i Records and documentation of information and testing results, which provide the basis for evaluation and which facilitate comparison with results from previous and subsequent tests, will be ~ maintained and available for the active life of the component or system in accordance with the ASME OM Code - 1990 Edition, Subsection ISTA 3. 1.7 METHODS OF TESTING t The method of testing applicable to each pump is listed adjacent to the component identification in the Pump IST Program Tables. The ASME OM Code does not stipulate any specific training / certification requirements for personnel involved in pump testing. At Plant Vogtle, all pump testing is performed by operations, maintenance or engineering personnel who have been l trained to perform specific testing tasks. 1 1.8 STANDARDS FOR TESTING EVALUATION The acceptance criteria applicable for each pump to be tested have been developed in accordance with the ASME OM Code requirements as modified by any applicable relief requests. Acceptance criteria are not provided in the IST Program document, but are provided in the applicable surveillance testing procedures which are available for review at the plant site. O l-2 Rev.0

ABBREVIATIONS LIST Abbreviation Definition Acc Accuracy AFW Auxiliary Feedwater ' Amp. Amplitude ASME American Society of Mechanical Engineers atm. Atmospheric Aux Auxiliary Bldg Building CC ASME Code Class CCW Component Cooling Water Coord. Coordinate CS Containment Spray CVCS Chemical Volume & Control System AP Pump DifferentialPressure APr Reference DifferentialPressure Differ. Differential ECCS Eme gency Code Cooling System ESF Eagmeered Safety Feature F Fahrenheit FI FlowrateIndicator ft Feet Freq. Frequency GPC Georgia Power Company gpm Gallons Per Minute Hz Hertz I.D. Identification in/s Inches Per Second IST Inservice Testing kW Kilowatt LOCA Loss OfCoolant Accident LI LevelIndicator NA Not Applicable N Speed No. Number NPSH Net Positive Suction Head NSCW Nuclear Service Cooling Water OM ASME OM Code PC Vogtle Plant Project Class P&ID Piping & Instrumentation Diagram Pi Pump Inlet Pressure PI Pressure Indicator Po Pump Outlet Pressure psig Pounds Per Square Inch 21 Rev.O i

__.._....._.. _.._ _ _ _ _ ~ _........ _. _.. _ _ _. _ _. _.-. _ _ _ _..__ _ __ _. _._ _._... _.. 4 1 Abbreviations (cont.) i a Abbreviation Definition Q - Pump Flowrate Qtr. Quarterly Qr Reference Flowrate RCS Reactor Coolant System l Ref. Reference Req.~ Required RHR ResidualHeat Removal j rpm Revolutions PerMinute RR i ReliefRequest i SI SafetyInjection j-SI Speed Indicator SNC Southern Nuclear Operating Company V Vibration i VEGP Vogtle Electric Generating.'lant i Vib. Vibration Vr Reference Vibration Amplitude I t i I liO l 4 i 1 i O 2-2 Rev.0

INTRODUCTIGN A. Regulatory Position rN U This document defines the testing requirements for the pumps incicded for inservice testing ~ (IST) at Southern Nuclear Operating Company's (SNC) Vogtle Electric Generating Plant (VEGP) Unit I and 2. This Pump IST Program was developed to comply with the i provisions of 10 CFR 50.55a. The Code of record applicable for this program is the ASME OM Code - 1990 Edition. NRC Generic Letter 89-04 and its Supplement 1 (NUREG-1482) were used for guidance, to the extent practical, in the development of this program document. B. Ssage In accordance with 10 CFR 50.55a and NRC Regulatory Guide 1.26 (water, steam and radioactive waste containing systems), ASME Code Class 1,2 and 3 safety-related pumps which perform a function required in; 1) shutting the reactor down to the cold shutdown condition,2) maintaining the cold shutdown condition,3) or mitigating the consequences of an accident, and are provided with an emergency power source, are included in this program document for inservice testing. It was recognized that 10 CFR 50, Appendix A, General Design Criteria 1, and Appendix B, Criterion XI, intended that all pumps necessary for safe operation of the plant be tested to demonstrate that they will perform satisfactorily in service. The subject testing is to be [] performed to a level commensurate with the safety significance of the pump. For those non-L ASME Code Class 1,2 and 3 pumps, this testing is performed in accordance with the plant technical specifications and/or other plant testing programs and is not included in this program document. The determination as to whether a pump should be included in this testing program was performed by review and evaluation of the Updated Final Safety Analysis Reports (UFSAR) and other design and licensing documents. These documents were reviewed to determine 1 which pumps are required to respond to the design basis accident scenarios and provide a function required to shutdown the reactor, maintain the shutdown condition, or mitigate the consequences of the accident. C. Testine Reauirements A description of the ASME OM Code testing requirements applicable to pumps is provided in each section. The ASME OM Code-1990 Edition should be used in conjunction with this description to ensure a complete identification of the testing requirements. Subsection ISTB l of the ASME OM Code is applicable for pump inservice testing and the applicable ISTB paragraph is listed in parenthesis for cross reference. 1. Definitions (ISTB 1.3) l {v The below listed definitions are provided for easy reference as they are applicable to VEGP and are used in subsequent sections of this introduction. 0 3-1 Rev.0

inservice rest - a test to determine the operational readmess of a pump 3 i instrument accuracy - the allowable inaccuracy of an instrument loop based on the l square root of the sum of the square of the inaccuracies of each instrument or [ component in the loop-instrument loop - two or more instruments or components working together to provide i a single output (e.g., a vibration probe and its associated signal conditioning and readout devices) operationalreadiness - the ability of a pump to perform its intended function preservice testperiod - the period of time after completion of construction activities j related to the pump and before first electrical generation by nuclear heat, in which component and system testing take place 1 j pump - a mechanical device used to move liquid J reference values - one or more values of test parameters measured or determined when the equipment is know to be operating acceptably i routine servicing - the performance of planned, preventative maintenance (e.g., replacing or adjusting valves in reciprocating pumps, changing oil, flushing the cooling i system, adjusting packing, adding p*Wg rings or mechanical seal maintenance or replacement) l system resistance - the hydraulic resistance to flow in a system 2. Reference Information (ISTB 2) The hydraulic and mechanical condition of a pump relative to a previous condition can be determined by attempting to duplicate by test a set of reference values. Deviations detected are symptoms of changes and, depending upon the degree of deviation, indicate need for further tests or corrective action. 3. Owner's Responsibility (ISTB 3.1) Each pump to be tested in accordance with this program shall be identified by the Owner and listed in the plant records. 4. Testing Requirements (ISTB 4) 1 A. Preservice Testine (ISTB 4.1) j Each pump shall be tested during the preservice test period. These tests shall be conducted under conditions as near as practical to those expected during subsequent O inservice testing. Only one preservice test is required for each pump, except when a j pump is repaired or replaced (see C.4.D). I 3-2 Rev.O

B. Inservice Testina (ISTB 4.2) Inservice testing shall commence when the pump is required to be operable (see C.5.C). l3 t V C. Reference Values (ISTB 4.3) Initial reference values shall be determined from the results of the preservice test or from the results of the first inservice test. Reference values shall be established at points of operation readily duplicated during subsequent testing. All subsequent test results shall be compared to these initial reference values or to new reference values as appropriate (see C.4.E). Reference values shall only be established when the pump is known to be operating acceptably. If the particular parameter being measured or determined can be significantly influenced by other related conditions, then these conditions shall be analyzed. D. Effect of Pump Reolacement. Reoair. and Maintenance on Reference Values (ISTB 4.4) When a reference value or set of reference values may have been affected by repair, ],s replacement, or routine servicing of a pump, a new reference value or set of reference values shall be established in accordance with C.4.C above (ISTB 4.3), or the previous value(s) reconfirmed by an inservice test run before declaring the pump operable. Deviations between the previouc and new reference value(s) shall be evaluated, and verification that the new reference value(s) represent acceptable pump operation shall be placed in the record of tests. E. Establishment of Additional Set of Reference Values (ISTB a 5) If necessary or desirable, for some reason other than stated in C.4.D above, to establish an additional set of reference values, an inservice test shall be run at the conditions of an existing set ofieference values and the results analyzed. If operation is acceptable per C.5.B (ISTB 6.2), then a second test run at new reference conditions shall follow as soon as practical. The results of this test shall establish the additional set of reference I values. Whenever new reference values are established, the reason for doing so shall be l documented in the record of tests. fh 0 l I 3-3 Rev.O

.. - -. -. -- - -. -. ~ f' F. Instrumentation (ISTB 4.6) Instrument accuracy shall be within the limits of the below table (Table ISTB 4.6.1-1). Station instruments meeting these requirements are acceptable. j ACCEPTABLE INSTRUMENT ACCURACY (Table ISTB 4.6.1-1) l j Percent Quantity [ Note (1)] Pressure i2% l Flow Rate ' i2% ~ 1 Speed i2% i j Vibration iS% DifferentialPressure i2% i NOTE: Y (1) Percent of full scale for individual analog instruments, percent of total loop accuracy for a combination ofinstruments, or over the calibrated range for digital j instruments. i { The full-scale range of analog instruments shall not be greater than three times the i reference value. Digital instruments shall be selected such that the reference value does not exceed 70% of the calibrated range of the instrument. j Vibration instruments are excluded from the range requirements stated above. The i frequency response range of vibration measuring transducers and their readout system 1 shall be from one-third minimum pump operating speed to at least 1000 Hz. i The Owner shall be responsible for establishing the location of instruments used for { } inservice testing. The location shall be appropriate for the parameter being measured and the same location shall be used for subsequent tests. Instruments that are position-i { sensitive shall be either permanently mounted, or provisions shall be made to duplicate their position during each test. 1 j Instruments and instrument loops shall be cahbrated in accordance with the Owner's i quality assurance program New or repaired instruments shall be calibrated before test l use. 1 [ G. Pressure Memenrements (ISTB 4.6.2) l' i Differential pressure across a pump may be determined using a differential pressure gage i or a differential pressure transmitter that provides direct measurement of pressure difference, or the difference between pump discharge pressure and pump inlet pressure j shall be used. 1 1 3-4 Rev.0 1 i s , ~ - -m m-

4 H. Rotational Speed Man =nremente GSTB 4.6.3) a i Rotational speed measurements of variable speed pumps shall be measured by a method I that meets the instrument accuracy requirements of the above instrument accuracy table (C.4.F). c ) I. Vibration Man = e...=a GSTB 4.6.4) j p On centrifugal pumps, vibration measurements shall be taken in a plane approximately perpendicular to the rotatmg shaft in two orthogonal directions on each accessible D i j pump-bearing housing. Measurement shall also be taken in the axial direction on each accessible pump thrust bearing housing. t l On vertical line shaft pumps, measurements shall be taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction. If portable vibration instruments are used, the ' measurement points shall be clearly identified on the pump to permit repeatability in both location and plane. J. Flow Rate Ma==nremanta GSTB 4.6.5) Flow rate shall be measured using a rate or quantity meter installed in the pump test l circuit. If the meter does not indicate flow rate directly, the record of tests shall include the method used to reduce the data. j 5. Testing Methods (ISTB 5) A. Frequency ofInservice Tests GSTB 5.1) An inservice test shall be performed on each pump nominally every 3 months except for. pumps that are declared inoperable or are not required to be operable. B. Test Procabre GSTB 5.2) An inservice tests shall be conducted with the pump operating at specified test reference conditions. The test parameters listed in the below tables shall be determined and recorded. t i O 3-5 Rev.0

4 INSERVICE TEST PARAMETERS (Tchle ISTB 5.2-1) i Quantity Remarks Speed, N Ifvariable speed pump ~ i DifferentialPressure, AP ' Centrifugal pumps, including vertical line shaft I Pumps i l Discharge Pressure, P Positive displacement pumps Flow Rate, Q All pumps i i Vibration i Displacement, Vd Peak-to-Peak Velocity, VV Peak The pump shall be operated at nominal motor speed for a constant speed driver or at a speed adjusted to the reference point for variable speed drivers. The resistance of the system shall be adjusted until the flow rate equals the reference value. The differential pressure shall then be determined and compared to the reference value. Alternately, the flow rate shall be varied until the differential pressure equals the O reference value and the flow rate determined and compared to the reference flow rate value. If system resistance cannot be varied, flow rate and pressure shall be determined and compared to their respective reference values. Pressure, flow rate, and sihration shall be determined and compared with the corresponding reference values. All deviations from the reference values shall be compared with the acceptance criteria listed below and corrective action shall be taken as specified in Section C.6. Vibration measurements shall be broad band (unfiltered). Velocity measurements shall be peak and displacement amplitudes shall be peak-to-peak respectfully. O 3-6 Rev.0

VIBRATION ACCEPTANCE CRITERIA (Table ISTB 5.2-2a) Pump Pump Test Acceptable Alert Required /Q Type Speed Parameter Range Range Action Range V Centrifugal & <600 rpm Vd or VV 52.5Vr >2.5Vr to 6Vr or >6Vr or Venical Line >10.5 to 22 mils >22 mils i Shaft (Note 2) 4 Centrifugal & 2 600 rpm Vvor Vd s2.5Vr >2.5Vr to 6Vr or >6Vr or I VerticalLinc >0.325 to 0.7 in/sec >0.7 in/sec l Shaft (Note 2) Reciprocating Vd or Vr s2.5Vr >2.5Vr to 6Vr >6Vr NOTES: (1) Vr is reference vibration value in selected units. (2) Refer to OM Code Figure ISTB 5.2 1 to establish di=!=~nt limits for pumps with speeds 2 600 rpm or velocity limits for pumps with speeds s 600 rpm. l HYDRAULIC ACCEPTANCE CRITERIA (Table ISTB 5.2-2b) Acceptable Required Action Range Test Parameter Range Aled Range Low High I a I ('T P (Positive Displacement Pumps) 0.93 to 1.10Pr 0.90 to <0.93Pr <0.90Pr >1.10Pr U AP (VerticalLine Shaft Pumps) 0.95 to 1.10APr 0.93 to <0.95APr <0.93APr >l.10APr Q(Positive Displacement and 0.95 to 1.10Qr 0.93 to <0.95Qr <0.93Qr >1.10Qr VerticalLine Shaft Pumps) AP (Centrifugal Pumps) 0.90 to 1.10APr none <0.90APr >1.10APr Q (Centrifugal Pumps) 0.90 to 1.10Qr none <0.90Qr >1.10Qr C. Pumos In Systems Out of Service GSTB 5.4) For a pump in a system declared inoperable or not required to be operable, the test schedule need not be followed. However, within 3 months before the system is placed in an operable status, the pump shall be tested. Pumps that can only be tested during plant operation shall be tested within I week following startup. i ( D. Duration ofTests GSTB 5.6) After pump conditions are as stable as the system permits, each pump shall be run for at least 1 2 minutes prior to measuring any ofthe required test parameters. !O 3-7 Rev.O t

..~- -. - - _ -. .... ~.. -.. 6. A::alysis czd Ev:.1=ti:2 (ISTB 6) A.- Acceptance Criteria GSTB 6.1) 4 b Ji U If the measured test parameter values fall within the alert range of the applicable table (see - [ C.S.above), the frequency of testing shall be doubled until the cause of the deviation is determined and the condition is corrected. If the measured test parameter values fall within the required action range of the applicable j table (see C.5 above), the pump shall be declared inoperable until either the cause of the deviation has been determined and the condition corrected. (See ReliefRequest RR-P-2) 2 ) When a test shows measured parameter values that fall outside the acceptable rarges that have resulted from an identified system error (e.g. improper system lineup, inaccurate instruments) the test shall be rerun after correcting the error. B. Time Allowed for Analysis ofTests GSTB 6.2) ? l All test data shall be analyzed within 96 hours after completion of test. i - 7. Records and Reports (ISTB 7) a j A. Pumo Records GSTB 7.1) fj The Owner shall maintain a record, for each pump included in the program, that includes the j' followinginformation: ) 1 { I (a) the manufacturer and the manufacturer's model and serial number or other identification i

number, j

(b) a copy or summary of the manufacturer's acceptance test report if available; and (c) a copy of the pump manufacturer's operating limits. B. Inservice Test Plans GSTB 7.2) i The Owner shall maintain a record of test plans and procedures that shall include the following: i (a) the hydraulic circuit to be used; (b) the location and type of measurements for the required test parameters; (c) the reference values; and 1 (d) the method of determining test parameter values that are not directly measured by instrumentation. This Pump IST Program document in conjunction with the pump surveillance test procedures satisfy the above requirement. O 3-8 Rev.0

C. Record ofTests USTB 7.3) The Owner shall maintain a record of each test that shall include the following: . (s) pump identification;. ~ (b) date of test; . (c) reason for test (e.g. post-maintenance, routine inservice test, or establishing new reference values);

(d) values ofmeasured parameters; (e) identification ofinstruments used; (f) comparisons with allowable ranges of test values and analysis of deviations; (g) requirements for corrective action; (h) evaluation andjustification for changes to reference values; and (I) signature of the person (s) responsible for conducting and analyzing the test data.

This Pump IST Program document in conjunction with the pump surveillance test procedures satisfy the above requirement. D. Record ofCorrective Action GSTB 7.4) The Owner shall maintain records of corrective action that shall include a summary of the corrections made, the subsequent inservice tests and confirmation of operational adequacy, and the signature of the individual (s) responsible for corrective action and verification of results. O O 3-9 Rev.0

. -. _. ~ -... - -... - -. O O VEGP-1 PUMP TEST TABLE Nuclear Service Cooling Water - System 1202 Measured Parmarters & Frm i LD. Number CC/PC PalD-Sheet No. _CM Description h E R Y E NW Gulal (a:D isa!al theerl smal I l-1202-P4-001 3D13 IX4D1133-1 C-8 NSCW Pump QTR QTR QTR QTR NA RR-P-2 1-1202-P4-002 3813 IX4DB133-2 C-5 NSCW Pump QIR QTR QTR QIR NA RR-P-2 + i 1-1202-P4-003 3813 IX4DB133-1 C-5 NSCW Pump QTR QTR QTR QIR NA RR-P-2 1-1202-P4-004 3/313 IX4DB133-2 C-5 NSCW Pump QIR QTR' QTR QTR NA RR-P-2 1-1202-P4-005 3D13 IX4DB133-1 C-7 NSCW Pump QTR QTR QIR QTR NA RR-P-2 1-1202-P4-006 3D13 IX4DB133-2 C-7 NSCW Pump QIR QTR QTR QIR NA RR-P-2 1-1202-P4-007 3D13 IX4DB133-1 C4 NSCW Transfer Pump QTR QTR QTR QTR NA RR-P-2 1-1202-P4-008 3D13 IX4DB133-2 C-6 NSCWTransfer Pump QIR QIR QTR QIR NA RR-P-2 i Test Frequency: QIR = Quarterly Pump Test I i 4-1 Rev.O I r - - = - - - - - - - - - - - - - ' ^ ' ^ ' " - - ~ - - - ' ^ ^ ^

___m.._ m.._._ O O O VEGP-1 PUMP TEST TABLE Compoecat Cooling Water - System 1203 Measured Pas ___;a.e & Fm LD. Number QC/PQ P&ID-Sheet No.

Coord, Descristion fe R

Q V H RR/ Remarks fagl 1 fa!D (snel (heus) (en) 1-1203-P4-001 3/313 IX4 dbl 36 H-4 CCW Pump Q1R QTR QTR QTR NA RR-P-2 1-1203-P4-002 3/313 IX4DB136 D-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 i 1-120'i-P4-003 3/313 IX4DB136 G-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 1-1203-P4-004 3/313 IX4DB136 C-4 CCW Pump QTR QTR Q1R QTR NA RR-P-2 1-1203-P4-005 3/313 IX4DB136 F-4 CCW Pump QTR Q1R QTR QIR NA RR-P-2 1-1203-P4-006 3/313 IX4DB136 B-4 CCW Pump QTR QTR Q1R QTR NA RR-P-2 I Test Farquency: QTR = Quarterly Pump Test L r i i t 4-2 Rev.O I

..... ~. _..... _ _.. . - - ~ . ~ - - VEGP-1 PUMP TEST TABLE t Safety lajection - System 1204 Measured Parameten & Freescacy LD. Number CC/PC P&ID-Sheet No. Coord. Description h AE 9. Y M RR/ Remarks (a!!al fa!!1 Onual h) Daisl 1-1204-P6-003 2/212 IX4DB121 E-2 SIPump QTR QTR QTR QTR-NA RR-P-2 1-1204-P6-004 2/212 IX4DB121 C-2 SIPump QTR QTR QTR QTR NA RR-P-2 Test Frequency: QTR = Quarterly Pump Test t b i f r v 'i i 4-3 Rev.0 L I

.. - = _ ~ _ ~... . ~... O O O VEGP-1 PUMP TEST TABLE I Residual Heat Removal-System 1205 i Measured Paranneters & Freauency 1 LD. Number CC/PC P&ID-Sheet No. Coord. Description P2 R .Q y M RR/ Remarks (Mal (eG (smal &=ci fouel 1-1205-P6 @ l 2/212 IX4DB122 F-4 RHR Pump 'QTR QTR Q1R QIR NA RR-P-2 1-1205-P6-002 2/212 IX4DB122 G-4 RIIR Pump QTR QTR QTR QTR' NA RR-P-2 i Test Frepency: QTR = Quarterly Pump Test i i f I 4-4 Rev.0 m

(, t i VEGP-1 FIIMP TEST TABLE r Contahment Spray - System 1206 i I Measured Parameters & Fr*==-=ar LD. N mber QC/PC P&ID-Sheet No. Coord. Descristlos Po AE _Q Y H RR/ Remarks fadal fa:D Gmed fw=c) trued l-1206-P6-001 2/212 IX4DB131 G-4 CS Pump QTR QTR QTR QTR NA RR-P-2 l-1206-P6-002 2/212 IX4DB13i C-4 CS Pump QTR QTR QTR QTR NA RR-P-2 i Test Frequency: QTR = Quarterly Pump Test 1 I D 4-5 Rev.O I

.n. VEGP-1 PUMP TEST TABLE Chemical & Volume Control - System 1208 Measured Parameters & Freauency I.D. N mber CC/PC P&lD-Sheet No. Coord. Description P_o _AP_ Q V N RR/ Remarks Ot!!rl (a!!1 framl da/wd Ltned 1-1208-P6-002 2/212 IX4DB116-2 G-4 CVCS - Centrifugal QTR QTR QTR QTR NA RR-P Charging Pump t 1-1208-P6-003 2/212 IX4DBil6-2 C-4 CVCS - Centrifugal QTR QTR QTR QTR NA RR r.y. Charging Pump D-4 CVCS-Boric Acid QTR QTR QTR QTR NA RR-F-1, RR-P-2 1-1208-P6-006 3/313 IX4DB118 Transfer Pump 1-1208-P6-007 3/313 IX4DB118 B-4 CVCS - Boric Acid QTR QTR QTR QTR NA RR-P-1, RR-P-2 Transfer Pump Test Frequency: QTR = Quarterly Pump Test 4-6 Rev.0

O O O VEGP-1 PUMP TEST TABLE i Auxili;ry Feedwater - System 1302 I Measured Parameters & Preemency LD. Number CC/PC P&ID-Sheet No. Coord. Description Po AP Q V N RR/ Remarks Gulal fadl famed Gn w fraud i 1-1302-P4-001 3/313 IX4DB161-2 F-6 AFW Pump QTR QTR QTR Q1R NA RR-P-2 'Ihrbine Driven 1-1302-P4-002 3/313 IX4DB161-2 D4 AFW Pump Q1R Q1R Q1R Q1R NA' RR-P-2 Motor Driven 1-1302-P4@3 3/313 IX4DB161-2 B4 AFW Pump QTR QfIR QTR QTR NA RR-P-2 Motor Driven Test Frequency: QTR = Quarterly Pump Test s v b b i F I 1 L 4-7 Rev.0 [

- _ = - - - _ - - - - - _ - - _ _ - _ _ - - - _ - _ _ - - - - - - _ - - - _ - - - - _ _ - - - - -._ - - __ - -- - --_-__----- - O O O VEGP-1 PUMP TEST TABLE Safety Related (ESF) Chillers - System 1592 i Measured Parameters & Freaucacy i LD. Number, CC/PC P&ID-Sheet No. Coord. Description P AE .Q V N! RR/Researks _3 fa:Isl &!Il fanal (Mt!s) frauni 1 1-1592-P7-001 3813 IX4DB221 F-5 ESF Chilled Water Q1R QTR QTR QTR NA RR-P-2 Pump 1-1592-P7-002 3B13 IX4DB221 C-5 ESF Chilled Water Q1R QTR Q1R' Q1R' NA RR-P-2 f Pump Test Frespency: QIR = Quarterly Pump Test l i 4-8 Rev.0 u a +-

..~..._ _ _ _ _ _. _ __ NSCWPumps (1-1202-P4-001, 002, 003, 004, 005, & 006) l l System Function l Provide cooling water for the containment coolers, control building essential chiller condensers, various engineered safety feature pump motor and lube oil coolers, and the component cooling water and auxiliary component cooling I water diesel generator jacket water heat exchangers and transfers the heat removed to the ultimate heat sink. Quantity 6 l Type Vertical Line Shaft, 2 stage, selflubricated Manufacturer /Model Bingham-Willamette/18x27B VCM i Rated Capacity 8600 gpm(each) Rated TotalDynamic Head 230 feet Driver i Type Electric Motor l l Horsepower 700 Speed 1180 rpm Power Supply. 4160V,60 Hz,3 phase Code Class 3 i Project Class ~ 313 Outline Drawing IX4AF02-32 l i Instruction Book 1x4AF02-93 1 Physical Location NSCW Pump House l P&ID 1X4DB133-1, -2 Surveillance Procedure 14802-1 Pump Test Loop Diagrams ISI-D-201 through ISI-D-206 i Test Parameter Sheets Page 5-3 through 5-8 l~ ) e !O 5-1 Rev.0 I

.__m ? NSCW Transfer Pumps (1-1202-P4-007, 008) System Function 1 Provides capability to transfer water between cooling tower basins. Quantity 2 i Type Vertical Line Shaft,2 stage, selflubricated i 1 Manufacturer /Model Bingham-Willamette/18x12A VCM i Rated Capacity 600 gpm (each) i 4' Rated TotalDynamic Head 110 feet Driver Type Electric Motor Horsepower 30 Speed 1765 rpm Power Supply 480V,60 Ih,3 phase Code Class 3 Project Class 313 O Outline Drawing IX4AF02-3 Instruction Book IX4AF02-95 PhysicalLocation NSCW Pump House P&ID 1X4DB133-1, -2 Surveillance Procedure 14801-1 Pump Test Loop Diagrams ISI-D-207 and ISI-D-208 Test Parameter Sheet Page 5-9 and 5-10 O 5-2 Rev.0

.m O~ v + l Test Parameter Table - Pump 1-1202-P4-001 (Figure ISI-D-201) j Instrumentation Utilized Ref. Acceptable Alert Action Earameter Test Freq. I.D. No.f4) Bange Req. Acc. Value Range Bange Bange Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1606 NA (1) NA NA ~ NA NA Measure basin level j (Pi) Outlet Pressure Qtr PI-2148 0-200 12% NA NA NA NA NA (Po) psig Differ Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA i (AP) l Flowrate Qtr FI-l 1760 0-15000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm j Vib. Amp. Qtr (3) NA 15% Vr 5; 2.5Vr >2.5Vr - 6Vr >6Vr or 1,A (V)(5) or >.325 in/s >.70 in/s ? N:tes: t

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.

t

3. Portable vibration instmments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

j,

5. Measurements are taken on the upper motor-bearing housing in three onhogonal directions, one of which is the axial direction.

i L 5-3 Rev.0 { -rw

( Test ParameterTable - Pump 1-1202-P4-002 (Figure ISI-D-202) Instrumentation Utilized Ref. Acceptable Alert Action P_aramritt Test Freq. LD. No.(4) Range Req. Acc. Yalut Bangt Range Range Comments i Speed l (N) NA NA NA MA NA NA NA NA Constant speed driver l Inlet i Pressure Qtr LI-1607 NA (1) NA NA NA NA Measure basin level (Pi) Outlet Piessure Qtr PI-2149 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr (2) NA 12% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr FI-l1763 0-15000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA i5% Vi s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s j Notes:

1. Basin level indicator is utilized to determine icvel in feet.

[

2. DifTerential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

t 5-4 Rev.0 I i u mm m t---

O O Test Parameter T$ble - Pump 1-1202-N-003 (Figure ISI-D-203) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freg, LD. No.(4) Range Req. Acc. Yalue Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver i U Inlet Pressure Qtr L1-1606 NA (1) NA NA NA NA Measure basin level (Pi) Outlet f Pressure Qtr PI-2152 0-200 12% NA NA NA NA NA i (Po) psig DitTer. Pressure Qtr (2) NA 12% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA i f (AP) Flowrate Qtr FI-I 1762 0-15000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. { A m p. Qtr (3) NA i5% Vr s 2.5Vr >2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s i f i t Notes: 1 +

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.

[

3. Portable vibration instruments are utilized.

[ L

4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

t 1 i 5-5 Rev.0 [ [ b .u-- e w o-w<w w w =-'i

O O O Test ParameterTable - Pump 1-1202-P4-004 (Figure ISI-D-204) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Iest Freg. I.D. No.f 4) Range ~ Req. Acc. Value Rangt Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr L1-1607 NA (1) NA NA NA NA Measure basin level (Pi) i Outlet Pressure Qtr PI-2153 0-200 12% NA NA NA NA NA i (Po) psig DitTer. 4 Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr F1-11765 0-15000 12% Qr NA NA NA Flowrate is set at reference value l (Q) gpm Vib. I A m p. Qtr (3) NA 15% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s I Notes: i

1. Basin level indicator is utilized to determine level in feet.
2. IMfferential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discrenon of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

5-6 Rev.0 t i

O O O Test Parameter Table - Pump 1-1202-P4-005 (Figure ISI-D-205) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. LD. No.(4) Range Req. Ace. Yalue Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1606 NA (1) NA NA NA NA Measure basin level (Pi) Outlet Pressure Qtr PI-2150 0-200 12% NA NA NA NA NA i l (Po) psig Differ. Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 <.95APr <.93 or >1.10APr NA (AP) Flowrate Qtr FI-l 1761 0-15000 t2% Qr NA NA NA Flowrate is set at reference value l (Q) gpm r Vib. Amp. Qtr (3) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA l (V)(5) or >.325 in/s >.70 in/s i ( f Notes:

1. Basin level indicator is utilized to determine level in feet.

f

2. DifTerential pressure is calculated using basin level (to vetermine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.

[

4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of w hich is the axial direction.

L i 5-7 Rev.0 [

O O O Test Parameter Table - Pump 1-1202-P4-006 (Figure ISI-D-206) Instrumentation Utilized Ref. Acceptable Alert Action P_arameter Test Freq. I.D. Nol4) Range Rea. Ace. Yalue Range Range Range Comments r Speed (N) NA NA-NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1607 NA (1) NA NA. NA NA Measure basin level (Pi) l Outlet Pressure Qtr PI-2151 0-200 12% NA NA NA NA NA e (Po) psig i Differ. Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr FI-I1764 0-15000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm i Vib. Amp. Qtr (3) NA i5% Vr s 2.5Vr > 2.5Vr - (Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s Notes:

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

5-8 Rev.0 i

T bv Test ParameterTable - Pump 1-1202-P4-007 (Figure ISI-D-207) Instrumentation Utilized Ref. Acceptable Alert Action Paramtier Test Freo. I.D. No.(4) Bange Rea. Acc. Value Range Range Range Comtatnis Speed (N) NA NA NA NA NA NA NA NA Constant speed driver [ Inlet Pressure Qtr LI-1606 NA (1) NA NA NA NA Measure basin level i (Pi) Outlet i Pressure Qtr PI-8895 0-60 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr (2) NA 12% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr FI-2156 0-1000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vrer NA (V)(5) or >.325 in/s > 70 in/s Notes: t

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.

[ i

4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

I

5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

5-9 Rev.0

O O Test ParameterTable - Pump 1-1202-P4-008 - (Figure ISI-D-208) InstEnmentation Utilized Ref. Acceptable Alert Action { Parameter Test Freq. 1.D. No.f4) Range Reg. Acc. Value Range Range Range Comments i Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet t Pressure Qtr LI-1607 NA (1) NA NA NA NA Measure basin Icvel j (Pi) l Outlet Pressure Qtr PI-8894 0-60 12% NA NA NA NA NA j i (Po) psig DitTer. Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 - <.95APr < 93 or >l.10APr NA (AP) Flowrate Qtr F1-2157 0-1000 12% Qr NA NA NA Flowrate is set at reference value l (Q) gpm l i Vib. .t Amp. Qtr (3) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or .NA (V)(5) or >.325 in/s >.70 in/s Notes: } 1

l. Basin level indicator is utilized to determine level in feet.

+ I

2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.

l

4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

I i 5 - 10 Rev.0 I i

- _. _ _.. _... ~ _ _, _.. O O O NOTE: THIS IA A SIMPLIFIED DIAGRAM CV USED TO DEPICT A TEST CIRCUIT. 9446 'MC><]}---{MpCID ADDITION O REFER TO THE P8.ID FOR DETAILS, g (ggiD f6T4) BLIND FLANGE D TO 2' y ;

g TE FC BLOVDOVN Q23)

(172) M I, (4 3 plSPERSANT ADDITION - 1642 (0Z6) G V 0 S 3' (048) C e4-20 g 16* 18' S 4 0MCB 4 0MCB QMCB 1602A 1608A 1634 [ 18' 18' i g y l 11760 l 11761 l j 11762 NSCVS _~.v ~ b . COMPONENTS 24 PDI PI PDI PI PDI PI I 11726 2148 11727 2150 (11729 2152 I O 1668" L SrC QMCB -lbr" ' ll -lbrl ' ll gh 1606 HV HV HV 1160 1160 l i 11600 18' ,TO TGVER TO BASIN t me G m.AA: s /N /\\ /\\ 1-1202-P4-001 1-1202-P4-005 1-1202-P4-003 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4-001 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER TOVER r c.

== n c=-. mawres. nau m2 => nn. -3 =-ars s4.- as n ita, a nY n 3 7 4.-98 Cf. CV. tFDAM TO EV M tF IM400 33-i JK " " ~ ' " " Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT =$ = "

== =c

== vs UNIT 1 "C C' m, PUMP INSERVICE TESTING LOOP FOR neu. NUCLEAR SERVICE COOLING VATER PUMP l-1202-P4-001 N/A N/A ISI-D-201 1 [F 1 2 i i

-m.___._ ._._m.._. m. .. _._ - __,~..-....__. O O O i NOTE: THIS IA A SIMPLIFIED DIAGRAM CV i USED TO DEPICT A TEST CIRCUIT. 9447 M[>qj l'/pCID ADDITION (049) REFER TO THE PS.ID FOR DETAILS. (077) j-BLIND FLANGE b TU " l>4; l'AHf TE FC BLOVDOVN g g - 1643 I if X 'yISPERSANT ADDITION Q68) Cd797 (076) >{ 68 3' C050) O 24' 20' l6* 18' M QMCB g QHCB g QMCB 1603A 1609A 1635 18' W 1 g g 1 l 11763 l 11764 l 11765 1 le 1-i \\ -~* 669 NSCVS l 24-COMPONENTS t - ~. v W PDI PI PDI PI PDI PI ll l ~ 11730 2149 11731 2151 11733 2153 l i l O Il Il h 1669B -dist: 'F g Hist: ' ll -Hell ' l' 1607 HV HV HV 11612 11613 11607 18' , TO TOVER TO BASIN NAhMNLA /g j \\ E /~\\ /~\\ 1-1202-P4-002 1-1202-P4-006 1-1202-P4-004 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4-002 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER TOVER L my ante pr two sEs:kPruse appea arre2 arme.3 arva e areas moeurs s-e.-e. sas vs ism,rm n, n 3 7-f46 Cs3 CVS LFhhTE TD KV 10 F SK430123-2 JK Southern Company Services, Inc.roR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT -> "

    • " =

c"' vs UNIT 1 PUMP INSERVICE TESTING LOOP FOR ~ ui a ,,n, p .C NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-002 N/A N/A ISI-D-202 1 DF 1 2

\\ t V v NOTE: THIS IA A SIMPLIFIED DIAGRAM CV USED TO DEPICT A TEST CIRCUIT. 9446 'M[><3l "/F-ACID ADDITION N REFER TO THE P8.ID FOR DETAILS. (155) (040) (074) BLIND FLANGE FC OVDOVN - 1642 I / X syISPERSANT ADDITION I' (156) (076) (075) S 3' ,048) ( 0 24' 20* OMCB QMCB QMCB [6' 18' H 1602A 1608A 1634 18' 18' 1 g l 11760 l 11761 l 11762 1 l a {a 1668 g NSCVS ~ ~ " 24. COMPONENTS -.v - ~. " PDI PI PDI PI PDI PI ,li 11726 2148 11727 2150 11729 2152 h O h i l b 1668B -il;rll DMCB -ll>rll ' ll -U>rl' H GIT 1606 HV HV HV 1160 11606)

== 11600 18' , TO TOVER TO BASIN N,_AhhNL V /~\\ /~\\ /~\\ 1-1202-P4-001 1-1202-P4-005 1-1202-P4-003 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4 -001 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER TDVER .,t o., wa.,v o. -u -u ms

=== s ve.- .as vs i:=>r= m n R ?-24-M Cs3 CVW L*3 ATE TO MV 96 EF INGDR173-0 JK e

+

=

==aw m onis MS Southern Company Services. Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT==* "

== =c "m' vs UNIT 1 PUMP INSERVICE TESTING LOOP FOR 5."S b"." me, ~ muta .cy. NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-003 N/A N/A ISI-D-203 10F 1 2

O O O NOTD THIS IA A SIMPLIFIED DIAGRAM CV M[><]l lM}--- ACID ADDITION USED TO DEPICT A TEST CIRCUIT. 9447 N (041) (677) BLIND FLANGE REFER TO THE PtID FOR DETAILS. @ 2'; g D TO TE FC BLOVDOVN g - 1643 I M X yISPERSANT ADDITION s I' W M l S 3' (050) O 24' 20' QMC5 QMCB QMCB 16' 18' H 3 3 1603A 1609A 1635 t IO' I I 1 t j 11765 j 11764 l l 11763 l 1 1-I \\ {n 1669 g NSCVS 24' COMPONENTS .v PDI PI PDI PI PDI PI .I l E 11730 2149 11731 2151 11733 2153 7 O l 1669B -U;rij ' l}- O B --g;rll Hsrll t ' 'V 1607 HV HV H 11612 11613 11607 18' , TO TOVER TO BASIN MAM LMMG m i /~\\ /~\\ /~\\ 1-1202-P4-002 1-1202-P4-006 1-1202-P4-004 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE l-1202-V4-002 COOLING VATER PUMP CODLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE CDOLING (SPARE) VATER TOVER [ 6w ears se o=, uscuerase

==4

=

ma =e 4 was acuses D 9-**-84 BBS v3 IEILED Flut,tY FT l t de*-as css tvs urann to arv se y 1 4 set 33-a a ~ Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT K= 8'a" =c UNIT 1 ""' s o.5 v Ec=c corr r wtr i PUMP INSERVICE TESTING LOOP FOR ana mm. c. wr, av. NUCLEAR SERVICE COOLING VATER PUMP 1-1202-P4-004 N/A N/A ISI-D-204 1 [F 1 2

O O O NOTE: THIS IA A SIMPLIFIED DIAGRAM CV M C)<% MCID ADDITION USED TO DEPICT A TEST CIRCUIT. 9446 2'g (fy-) REFER TO THE PLID FOR DETAILS. Mt g BLIND FLANGE D TO

g W TE FC BLOVDOVN g

g 1642 I f X yISPERSANT ADDITION s i >S (075) 3' (048) 24' 20-l6* 18* M QMCB 4 0MCB g DMCB 1602A 1608A 1634 18' W 1 g g j 11760 l 11761 l 11762 1 1-la 1668 NSCVS ~ ~. " ~T" 'd 24. COMPONENTS . s PDI PI PDI PI PDI P7 I, i 11726 2148 11727 2150 11729 2152 g gy g h 1668B -iwi y -Hwl: -iwl: HV HV l1606 ) 1160 HV j 1160 11600 18' , TO TGVER TO BASIN MJM A GMM / \\ / \\ / \\ 1-1202-P4-001 1-1202-P4-005 1-1202-P4-003 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4-001 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER TOVER 7 av.

== or ci usc.er== -i .,,u -3 mi s s-e+ ma vs issu n n, n I 7-# * -# CSS Cwp treaYt 10 WEV 161F lx4Det33-t JK "~"~ Southern Company Services. Inc.FOR Southern Nuclear Operoling Company i V0GTLE ELECTRIC GENERATING PLANT K5=*

== "c 5 UNIT 1 PUMP INSERVICE TESkING LOOP FOR ",,,an a $am mr erv. NUCLEAR SERVICE COOLING VATER PUMP l-1202-P4-005 N/A N/A ISl-D-205 1 Ir 1 2 f -s w a -t

O O O t NOTE: THIS IA A SIMPLIFIED DIAGRAM CV MC><]HyCID ADDITION ' USED TO DEPICT A TEST CIRCUIT. 9447 (049F 04L) (077) BLIND FLANGE REFER TO THE P8,ID FOR DETAILS. Q6J7) 2'(gW 0 g TO TV FC BLOVDOVN g - 1643 I / X / nISPERSANT ADDITION 8 V ci6Tn cum L0z8) 3* S g c e4 go. l6* 18* M OMCB g DMCB g GMCB 1603A 1609A 1635 18" 18' I I a = l 11763 l 11764 l 11765 =p =8 =p i 1669 Q NSCVS g ~' 24* COMPONENTS is ~ PDI PI PDI PI PDI PI ll ll [ 11730 2149 11731 2151 11733 2153 Nb j l h O i 1669B d)(0 'U -0)(C 'E -lJfC 'l ~ 1607 HV HV i HV 1 612 11613 =, 11607 18 , TO TOVER. TO BASIN M}A.) G L G / \\ /~\\ /~\\ I 1-1202-P4-002 1-1202-P4-006 1-1202-P4-004 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 1-1202-V4-002 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING f (SPARE) VATER TOVER t e 1: o. scane mi me =u =s

==srs t 3- .= wi nm. r=,n n 9 7-f*-M CiB CVD LPenfE TO WV 30 IF IM450133-2 JK

  • ~*"

Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERAT.NG PLANT 8ES=8 n = " 3 UNIT 1 " " ' v5 PUMP INSERVICE TESTING LOOP FOR ~,Enna SC C" m, .y. i NUCLEAR SERVICE COOLING VATER l PUMP 1-1202-P4-006 N/A N/A ISI-D-206 1 IF 1 2

O O O NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TO PLID FOR DETAILS HV FI 1670 2156 pg 8895 a ls, v s g e e LO M" g GMCB FI HV 2 54 .LD ei 4 4 6-PI 6' 2155 PDI 0" O 11728 PI 1606 8894 QMC O PDI m 1173 r WMAMM JM)JM. M / /_ 3 r 1-1202-P4-007 1-1202-P4-008 TRANSFER PUMP 1-1202-V4-001 TRANFFER PUMP 1-1202-V4-002 NUCLEAR SERVICE COOLING NUCLEAR SERVICE COOLING VATER TGVER VATER TOVER

  • tv-SmTc BT cier"5 KstBFTEDI AFFRJ APFH2 appet3 arFR4 APPR.S E3tWKS

.-e.- so. n

mes,= m n

i i 1-e.-es cs cv. up.m m u-uv i a

u. san-e av. m ut l

U'I "$ [.",", [ [y"3 Southern Company Services. Inc.FOR Southern Nuclear Operating Company VOGTLE ELECTRIC GENERATING PLANT "5=* "a" "c UNIT 1 PUMP INSERVICE INSPECTION LOOP Ra. 527 s,an ~ FOR TRANSFER PUMP l-1202-P4-007 N/A N/A ISI-D-207 10F 1 3

NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. t REFER TO PLID FOR DETAILS HV FI 1670 2156 pg 8895 ,l, n_ ii i i LO QMCB i FI HV 2166 2157 1671 167A pg 2154 LO [ Mll l l [ 6-PI PDI V QMCB 11728 PI 1606 8894 QMCB i PDI m 1173 r + WhAAA.A.A> N. A A A.A.A.A d v vNJhhh /~\\ I f / \\ y 1-1202-P4-007 1-1202-P4-008 TRANSFER PUMP 1-1202-V4-001 TRANSFER PUMP 1-1202-V4-002 l NUCLEAR SERVICE COOLING NUCLEAR SERVICE COOLING VATER TOVER VATER TOVER e .,c o, mawen. -2 nm nm -4 .-s 5-e4-e4 iss vi uma nBe n, n 3 ,-24-95 CSS tv5 tatafE TO luem Ev 14 dBG IN4BBi33-e EEV. W J.I I e s-i4-se Cte vs apK3 pg gag ggyi DeWEE9 Pt 2135 TU ef34 WLW MB Southern Company Services, Inc.FOR Southern Nuclear Operating Company 3 e-e-w

w.

..c 3 m V0GTLE ELECTRIC GENERATING PLANT KK8

== '"e UNIT 1 PUMP INSERVICE INSPECTION LOOP ~,. m ",'.~v,.*h*" m1, ~ .v. FOR TRANSFER PUMP .1-1202-P4-008 N/A N/A ISI-D-208 1 IF 1 3

J CCWPumps (1-1203-P4-001, 002, 003, 004, 005, & 006)

p)

System Function Remove waste heat from the spent fuel pool heat u exchangers, RHR heat exchangers and the RHR pump seal } coolers during plant operation, plant cooldown and during a postulated post-accident condition.~ This heat energy is then transferred by the component cooling water heat exchangers to the NSCWS. The CCWS functions as an intermediate system between a radioactive fluid system and 1 the non-radioactive NSCWS, which operates at a higher system pressure. This arrangement greatly reduces the i probability ofradioactive fluid leakage to the enviroment by means of the NSCWS. J 4 Quantity - 6 ) Type. Horizontal, centrifugal, single-stage, split volute with mechanical seals [ Manufacturer /Model Ingersoll-Rand /10x18 SE l Rated Capacity 5000 gpm (each) i~ Rated Total Dynamic. Head 160 feet iO I Driver Type Electric Motor, Westinghouse, LAC-LLD, 5008-S Horsepower 300 { Speed 1761 rpm j Power Supply 4160V,60 Hz,3 phase Code Class 3 1 Project Class 313 j Outline Drawing IX4AF01-67 & 1X4AF01-70 i l Instruction Book X4AF01-136 Physical Location Aux Bldg, Level A, Rooms R-A03 & R-A05 i P&ID 1X4DB136 i Surveillance Procedure 14803-1 i Pump Test Loop Diagrams ISI-D-209 through ISI-D-214 w Test Parameter Sheets Page 6-2 through 6-7 6-1 Rev.O i 1

O O O4 Test Parameter Table - Pump 1-1203-P4-001 (Figure ISI-D-209) Instrumentation Utilized ~ Ref. Accepuble Alert Action Earameler Int Freq. 1.D. No.01 Range Rea. Acc. Yalue Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver l Inlet Pressure Qtr PI-1878 0-60 12% NA NA NA NA NA i (Pi) psig Outlet Pressure Qtr PI-1858 0-200 12% NA NA NA NA NA i y (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA f (AP) j Flowrate Qtr F1-11794 0-10000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm t Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA [ (V)(4) or >.325 in/s >.70 in/s Notes: i

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

l 6-2 Rev.0 - -n

Test Parameter Table - Pump 1-1203-P4-002 (Figure ISI-D-210) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Irst Freq. I.D. No.f3) Range Rec.Acc. Value Range Rangt Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure _ Qtr PI-1881 0-60 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1859 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er > l.10APr NA (AP) Flowrate Qtr F1-11795 0-10000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or>.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

6-3 Rev.0 E

O O O i Test Parameter Table - Pump 1-1203-P4-003 (Figure ISI-D-211) Instrumentation Utilized Ref. Acceptable Alert Action Paramettr Test Frea. I.D. NoJ3) Range Rea. Acc. Value Range Bange Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet . Pressure Qtr PI-1879 0-60 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1860 0-200 2% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) r Flowrate Qtr F1-11796 0-10000 12% Qr NA NA. NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr 5 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s > 70 in/s b Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

i

4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-beanng housing and in the axial direction on each accessibie thrust bearing housing.

i 6-4 Rev.0 l 4

p s. O V Test Parameter Table - Pump 1-1203-P4-004 (Figure ISI-D-212) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. 1.D. No.01 Range Rea. Acc. Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-1882 0-60 12% NA NA NA NA NA (Pi) BC(2) psig Outlet Pressure Qtr PI-1861 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA < 90 or >l.10APr NA (AP) Flowrate Qtr F1-11797 0-10000 t2% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr <; 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s 5 Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.

i

3. At the dircretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

i

4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

6-5 Rev.0 m --

O O Test Parameter Table - Pump 1-1203-P4-005 (Figure ISI-D-213) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freo. I.D. NoJ3) Range Rea. Acc. Value Bange Range Bange Comments Speed (N) NA. NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-1880 0-60 2% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1862 0-200 12% NA NA NA NA NA i (Po) psig DifTer. I Pressure Qtr NA(1) NA i2% APr .90 - I.10APr NA <.90 or >I.10APr NA (AP) Flowrate Qtr FI-l 1798 0-10000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s i i t I. Notes:

1. DifTerential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.

l

3. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

6-6 Rev.0 I t-

/m em Os U U Test Parameter Table - Pump 1-1203-P4-006 (Figure ISI-D-214) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea. I.D. No.(3) Range Rea. Ace. Value Range Range flanFe Comments ' Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-1883 0-60 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1863 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er >l.10APr NA (AP) FI-Il799 0-10000 12% Qr NA NA NA Flowrate is set at reference value Flowrate Qtr (Q) gpm Vib. Amp. Qtr (5) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s N ites:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

6-7 Rev.O u

_.~_._... _. _. . -... _. - - =.. O O o/ M OMCB PI gy NOTE: THIS IS A SIMPLIFIED HV PI 1852A FI DIAGRAM USED TO DEPICT 1858 11803 11800 1878 1179 A TEST CIRCUIT. REFER LD A l N '- 'I 1[ (030) 16' 1-1203-P4-001 } CMPNT. CLG. OMC VATER PUMP HV PI 54 U 1860 11 4 11801 1879 1179 10' LU LO c lN! l 'I I', th O 16' 1-1203-P4-003 CMPNT. CLG. VATER PUMP 18' OMC FI i PI HV 1179 HV PI 856 1862 11805 1180 1880 I CCVS l 18' LO l 10' e gi ha l = COMPONENTS 'I I', th \\ 16' 1-1203-P4-005 CMPNT. CLG. VATER PUMP I 20' (SPARE) 18' i! Is. i _L T LO HV 4' COMPONENT CLG. VATER 11807 'g gi HEAT EXCHANGER ? [1 03-a-001 COMPONENT CLG. VATER LO SURGE TANK HV 1-1203-T4-001 11806 L T LO 1866 -- z., EV. hfE l BY De*D K-- mPytJ mPPRA arse 2 appe.4 appa3 N 8 h ME vt IISLEB ftbr PET fl i r-e+= css cw wrte = is.eenas arv n JJC Southern Company Services, Inc.FOR Southern Nuclear Operating Company VOGTLE ELECTRIC GENERATING PLANT =8=* c UNIT 1

    • =* vs PUMP INSERVICE TESTING LOOP FOR m

EU' n .v. COMPONENT CDOLING VATER PUMP 1-1203-P4-001 N/A N/A ISI-D-209 IT1 2

m. __.. b Cf*~ i v i M QHCB PI HV NOTE: THIS IS A SIMPLIFIED HV PI 853 FI 1859 11811 DIAGRAM USED TO DEPICT r 11808 1881 II79 A TEST CIRCUIT. REFER LO TO THE P&ID FOR DETAILS. LD A, lN i 16' 1-1203-P4-002 g4, CMPNT. CLG. OMCB VATER PUMP HV PI 855 1861 11 2 11797 i 118C9 1882 10' LO LO c lN: lN: I, h O 16' 1-1203-P4-004 CMPNT. CLG. VATER PUMP 18' PI HV 1179 O HV PI 857 1863 11813 11810 1883 f CCVS LO

10, g g;

fu, l 18' = COMPONENTS O h 16' 1-1203-P4--006 CMPNT. CLG. VATER PUMP j 20' (SPARE) 18',l i _a_ i i T LO i HV 4* COMPONENT CLG. VATER 11815 gi HEAT EXCHANGER i 1-203-G-002 COMPONENT CLG. VATER LO SURGE TANK HV l-p 1-1203-T4-002 11814 T t e a) 1T 1867 ~ ~ ~ i ar. mir o, = _. _ -u -u .-2

==. m-= 0 N 353 wt IIstE3 Ftp PET FI a i v-e.-es can ews urmece m u. ems avi, JJC b

  • ~"~

Southern Company Services. Inc.FOR Southern Nuclear Operating Company [ V0GTLE ELECTR ENERATING PLANT "_""

==z can

a. m. mar PUMP INSERVICE TESTING LOOP FOR n.

aum re =v. COMPONENT COOLING VATER PUMP f 1-1203-P4-002 N/A N/A ISI-D-210 1 IF 1 2

O O O M OMCB PI HV NOTD THIS IS A SIMPLIFIED HV PI 852Al FI 1858 11803 DIAGRAM USED TO DEPICT 11800 1878 1179 A TEST CIRCUIT. REFER to, To TME etiD roR nEraitS. , t o., t,g ,N., 1h ~ 16' 1-1203-P4-001 g4, CMPNT. CLG. QMC VATER PUMP HV PI 854 1860 11 4 I 11801 1979 1179 10' LO t LD lN: 16' 1 1-1203-P4-003 O e CMPNT. CLG. OMC g FI PI HV 1179 HV PI 56 1862 11805 I!B0 1880 f CCVS LD l 10' c .N' I' I = CU""U"ENTS N N IM (034) 16' 1-1203-P4-005 CMPNT. CLG. VATER PUMP 20' (SPARE) 18',l li 2 i i T LO HV 4' COMPONENT CLG. VATER 11807 ig l HEAT EXCHANGER 1-1203- & 001 COMPONENT CLG. VATER LD SURGE TANK HV l_ 1-1203-T4-001 11806 T t wa> 1-T ~~ 1866 r w =re e, =, =_. m. e ms vs usan rar m 1 L_ F-944 CSS CVS tPtm7ED 19 II490BM IEV B9 _ JC " ~ " " ' " Southern Company Services. Inc.rOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT 8t=* * " 8"' UNIT 1 "5 Sta.E espg CIgrTBEES EBe SEIT PUMP INSERVICE TEST 1HG LDDP FDR =v. COMPONENT COOLING VATER PUMP 1-1203-P4-003 N/A N/A ISI-D-211 1 (F 1 2

O O O 1 S QMCB PI HV NOTE: THIS IS A SIMPLIFIED ' HV PI 1 A FI DIAGRAM USED TO DEPICT 1859 11811 11808 1881 1179 A TEST CIRCUIT. REFER 10' - hD TO THE P8.ID FOR DETAILS. L,D i.Ni p' g ~ 16' 14' 1-1203-P4-002 O CMPNT. CLG. g4 OMC VATER PUMP HV PI 55 II 18 1 11 11809 1882 11797 10' LD LO 'Ni l i N gh 16' 1-1203-P4-004 CMPNT. CLG. DMC Fb PI HV 1179 HV PI 857 1C63 11813 11810 1883 J CCVS 10, g ,q fu, l 18' LO = COMPONENTS N 1 1-1203-P4-006 O 16* [ CMPNT. CLG. VATER PUMP 20' (SPARE) 18',I Ii _a_ i n T LO HV l 4' COMPONENT CLG. VATER 11815 L HEAT EXCHANGER [ COMPONENT CLG. VATER LO SURGE TANK HV- -I-i 1-1203-T4-002 11814 T e a> A T --GD 3867 =v.

== e, oo> =_. -2 m. =>-n e we.-

== vs nun ne m ti i t-e.-es esa ews woms is inesias av i, JX i e e-e-es m Auts arme s acams ope Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT mismus n sm== = UNIT 1 ""* vs PUMP INSERVICE TESTING LOGP FOR ".E u. av. COMPONENT CDOLING VATER PUMP 1-1203-P4-004 N/A N/A ISI-D-212 I [F 1 2 1 e m . m m .<+--nww +-w~+-. .--w +

l i MCB PI HV NOTES THIS IS A SIMPLIFIEld t HV PI FI DIAGRAM USED TO DEPICT 1858 11803 11800 1878 1179 A TEST CIRCUIT. REFER LD TO THE P&ID FOR DETAILS. i LO ' 10., ,q N IM 16' 1-1203-P4-001 g4, i CMPNT. CLG. OMC VATER PUMP HV PI 854 U 1860 11 4 1179 11801 1879 10' LO LD 'N i i N N 16' 032) 1 1-1203-P4-003 CMPNT. CLG. VATER PUMP 18' QMC O HV PI 856 1862 11 5 1180 1880 1179 CCVS 1 LO M N' COMPONENTS 18' 1h (034) 16' 1-1203-P4-005 CMPNT. CLG. VATER PUMP 20' (SPARE) 18' el li _a_ i i T LO HV 4' COMPONENT CLG. VATER 11807 ge HEAT EXCHANGER 1-1203-a-001 COMPONENT CLG. VATER LO

  • ~

SURGE TANK HV f 1-1203-T4-001 11806 GlfL9) 1T 1866 - -- e s-e.-e.

== wi num rar m t1 7-***

== ews wmnets is is.suas sity s, JJC "~"~ Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT sosien n an .mc UNIT 1

=== vs PUMP INSERVICE TESTING LOOP FOR "EC' m, COMPONENT COOLING VATER PUMP 1-1203-P4-005 N/A N/A ISI-D-213 i (F 1 2

t S QMCB PI HV NOTE: THIS IS A SIMPLIFIED HV PI 1853 FI 1859 11811 DIAGRAM USED TD DEPICT 11808 ! Gal 1179 A TEST CIRCUIT. REFER LD TO THE PLID FOR DETAILS. 10, e g LO i I', h 16* 1-1203-P4-002 CMPNT. CLG. g4, QMCB VATER PUMP HS l pg HV HV PI FI 1861 11812 11797 11809 1882 10' LD LO c lN: l l N 16' 1 1-1203-P4-004 (057) CMPNT. CLG. VATER PUMP 18' QMC F1 PI HV 1179-HV PI 857 1863 11813 I I 11810 1883 18 CCVS l C MP NENTS LD A .N. 16' 1 1-1203-P4-006 (059) l CMPNT. CLG. VATER PUMP 20' (SPARE) 18' iI I. _a_ n T LO HV 4' jp COMPONENT CLG. VATER 11815 i gi HEAT EXCHANGER COMPONENT CLG. VATER LO 1-1 03-M02 SURGE TANK HV l-1-1203-T4-002 11814 T w a) 1-T L 1867 ~ e s++ nu vs amanrm m ti a ve-as os cws wantra su smessas av is JJC I ~ ~ " ~ " " " Southern Company Services. Inc.FOR Southern Nuclear Operating Company j VDGTLE ELECTRIC GENERATING PLANT E8=<= = =c UNIT 1

=== vs PUMP INSERVICE TESTING LOOP FDR " E h " .ex, men. o COMPDNENT COOLING VATER PUMP 1-1203-P4-006 N/A N/A ISI-D-214 I (F 1 2 I

. = -.. - I I l l SIPumps (1-1204-P6-003, & 004) G System Function The SI system provides emergency core cooling and serves k.) no other purpose. The primary function of the ECCS is to remove the stored and fission product decay heat from the reactor core following an accident in order to prevent fuel rod damage. Quantity 2 Type Horizontal, centrifugal,11-stage i 4 Manufacturer /Model Pacific Model 3-i t., JHF I Rated Capacity 440 gpm Rated Head 2680 ft. Driver Type Electric Motor, Westinghouse, Frame 5809 H Horsepower 450 Speed 3600 rpm l Power Supply 4160V,60 Hz,3 phase Code Class 2 Project Class 212 l Outline Drawing IX6AG02-10,13 & 15 Instruction Book IX6AG02-016 Physical Location Aux Bldg, Level B, Rooms R-BIS & R-B19 P&ID 1X4DB121 l Surveillance Procedure 14804-1 Pump Test Loop Diagrams ISI-D-215 & ISI-D-216 Test Parameter Sheets Page 7-2 & 7-3 4 4 O 7-1 Rev.O I { l

\\ t Test Parameter Table - Pump 1-1204-P6-003 (Figure ISI-D-215) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. No.(3) Range Rea. Ace. Yalum Range Range-Range Comments Speed 1 (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qr PI-0977 0-100 2% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr Test NA 12% NA NA NA NA NA i t (Po) Gage j Differ. Pressure Qtr NA(1) NA i ~. A APr .90 - 1.10APr NA <.90 er >l.10APr NA (AP) Flowrate Qtr FI-0968 0-100 12% Qr NA NA NA Flowrate is set at reference value [ (Q) gpm i Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi

[

2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

i

4. Measurements are taken in a plane approximately perpendicular to the routing shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

[ i 7-2 Rev.O l I t

O O O Test Parameter Table - Pump 1-1204-P4-004 (Figure ISI-D-216) Instrumentation Utilized Ref. Acceptable Alert Action EaramticI Test Freq. I.D. NoJ3) Range Req. Acc. Value Range Range Range comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-0978 0-100 12% NA NA NA NA NA 9 (Pi) psig l Outlet Pressure Qtr Test NA 12% NA NA NA NA NA I (Po) Gage Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er >l.10APr NA (AP) Flowrate Qtr FI-0968 0-100 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA 15% Vr 5 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s t Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instmmentation other than that listed, which meets the requirements of the OM Code, may'be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessi'i pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

7-3 Rev.0 ~+

/3 f3 d V V NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TD DEPICT M MCB FI HV 0968 A TEST CIRCUIT. REFER 8964 8964 TO THE P8.ID FOR DETAILS. MMCB 3/4" REFUELING VATER G88 j l PCP HV STORAGE TANK th0 ~ 8813 M 8813 HV HV 807 l HV q FC QMCB 1 1/2, 8814 802 HV g GMCD 8888 MCB 7 3' M 8814l CVCS CHARGING 802 k k 3/4, j QM B 807B ! PUMP 6, QMCB 4' SUCTION HEADER 093) 23 HV HV HS 807B m 821A HV M QMCB 0998 923 ,l 24" pg 00 (098) 0977 r' EI 207 LO 1-1204-P6-003 ~~ 6' SIS COLD 4* SAFETY INJECTION L HV LEG LDUP H PUMP 8806 82 B MCB QMCB 090 M 094) QMCB 8920 4 MCB 821B M PI HV QM B QMCB HV 101 802 11/2* 0978 4, g HS Dw r LO 1-1204-P6-004 6, (163) 802 k L SAFETY INJECTION M RHRS DISCHARGE QMCB 4' l DM TRAIN *B' 8 RHR HEAT EXCHANGER 3 9-ee-se ggig VS_ IISKs FtR PST I 7-e*-es em ev. waarts = ines.m arv. , JC rE $ E ."

  • 7. ".c "s Southern Company Services. lnc. FOR Southern Nuclear Operating Company

~~ VDGTLE ELECTR ENERATING PLANT =5" c PUMP INSERVICE TESTING LDDP n. ". ~ 2 = FOR SAFETY INJECTION PUMP 1-1204-P6-003 N/A N/A ISI-D-215 1 [F 1 3

(~ p /} O j NOTE: THIS IS A SIMPLIFIED I DIAGRAM USED TO DEPICT HS HV 68 A TEST CIRCUIT. REFER 8964 8964 TO THE P&lD FDR DETAILS. MCB 3/I G i l REFUELING VATLR 888 HV OM B PCP STORAGE TANK 8813 H TIS 1-204-T4 -001 807 10980 8813 M HV , r HV E 807 [ MCB 1 1/2, 8814 M 802 8888 ' QMCB P 3* M 8814 CVCS CHARGING 802 L 3/4' QM B 807B H PUMP 6' QM B 4' 093 92 HS 80 B 82 A HV M QMCB 0998 H Q.00 ' (098) pg A 923 I e4-w 0977 UM I, 821A M z i LO 1-1204-P6-003 0-D SIS COLD 4' 6' LEG LOOP g SAFETY INJECTION jl L HV H e PUMP 8806 HV 0919 8920 _ LD QMCB QMCB M HV 8806 821B - HV Q OMCB HV b0 101 ) 802 1 1/2' 0978 4, H HS r LO 1-1204-P6-004 0: D 802 k 6, L SAFETY INJECTION QMCB 4 PUMP RHRS DISCHARGE / l FROM TRAIN *B' 8 RHR HEAT EXCHANGER WV. 9ME BT M's K-.m appq3 appg3 appeJ appte a, pts Myuuurt e we= ma vi nuns run m tI a 7-e*

== . cvs urams to es.sma uv is - JJC rN m" [es.Ev~., C.,7 ~ " ~ m5 Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT = 5==

    • wa sac UNIT 1 y,,vs c

PUMP INSERVICE TESTING LOOP FOR SAFETY INJECTION PUMP 1-1204-P6-004 N/A N/A ISI-D-216 1 [F 1 3

RHR Pumps j (1-1205-P6-001, & 002) O System Function U The primary function is to remove heat energy from the i ~ reactor core and reactor coolant system during plant - cooldown and ra4*hg operations. As a secondary j function, RHR is used to transfer refueling water between the refueling water storage tank and the refueling cavity at the beginning and end of refueling operations. Portions of the RHR system also serve as part of the ECCS during the injection and recirculation phsses of a LOCA. Quantity 2 i Type Vertical, centrifugal, single stage Manufacturer / Mode! Ingersoll-Dresser,8X20WDF Rated Capacity 3000 gpm (- Rated Head 375 ft. Driver I Type Westinghouse LLD squirrel-cage induction motor O Horsepower 400 Speed 1780 rpm i Power Supply 4160V,60 Hz,3 phase Code Class 2 Project Class 212 } Outline Drawing AX6AF02-20007 l Instruction Book AX6AF02-20030 RHR Pumps (cont) Physical Location Aux Bldg, Level D, Rooms R-D48 & R-D49 P&ID 1X4DB122 ( Surveillance Procedure 14805-1 & 14812-1 l. Pump Test Loop Diagrams ISI-D-215 & ISI-D-216 Test Parameter Sheets Page 8-2 & 8-3 l l 81 Rev.0 I

_ _.. ~... - C O O f Test ParameterTable - Pump 1-1205-P6-001 (Figure ISI-D-217) Instrumentation Utilized Ref. Acceptable Alert Action Paramtitt Test Frea. LDJio4) Range Rtg. Acc. Value B.ange Range Range Comments t Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-8884 0-100 12% NA NA NA NA NA I (Pi) psig Outlet Pressure Qtr PI-8886 0-400 12% NA NA NA NA NA ( (Po) psig Differ. Pressure Qtr NA(1) NA 2% APr .90 - 1.10. ipr NA <.90 or >1.10APr NA (AP) i-i Flowrate Qtr FI-0618A 0-5000 12% Qr NA NA NA Flowrate is set at reference value I (Q) gpm l Vib. Amp. Qtr (2) NA 15% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s i Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

L

4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial

{ direction on each accessible thmst bearing housing. i t 8-2 Rev.0 j [ m

J O O Test ParameterTable - Pump 1-1205-P6-002 l (Figure ISI-D-216) Instrumentation Utilized Ref. Acceptable Alert Action Earamtitr Test Freq. I.D. No.(3) Range Reg. Acc. Yalut Range Rangt Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PlfS885 0-100 12% NA NA NA NA NA j (Pi) psig Outlet Pressure Qtr PI-8887 0-400 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr NA(1) NA 12% ' APr .90 - 1.10APr NA <.90 or > t.10APr NA (AP) t Flowrate Qtr FI-0619A 0-5000 i2% Qr NA NA NA Flowrate is set at reference value (Q) gpm x l Vib. A m p.- Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes: I

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

[

4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

f 8-3 Rev.0 i i. i

p Q U) f V (> NOTE: THIS IS A SlHPLIFIED FI FIC FROM CONTAINMENT DIAGRAM USED TO DEPICT 618 0618 FV 3, EMERGENi SUMP O dR ILS. OMC 00 M PI OMCE 061 8886 M HV REFUELING VATER 0618 HV ^ HV FT 0606 0620 8811 STORAGE TANK 809 M 0618 l (019 0612 PI l-1204-T4-001 SIS 8' - ll ll N---{-Q COLD LEG <l r0 1-1205-E6-001 LOOP 8' 2,, @l) J i 14 HV FIS M T PI QMCB 804 L FY 0610 5016 8884 H (12 2 ) g, g g CVCS CHARGING = 7 4 . 0618 CVCS LETDOVN 1-1205-P6-001 812y PUMP SUCTION - HEAT EXCHANGER RESIDUAL HEAT 1 r HV HEADER Ml 15 se REMOVAL PUMP J L M 812 - HV HV 8' LC, LC 840 716 ,m, RCh0W1 m, i r, - 9 12' 24' RHT(027) (226) FV 3 RCS 0611 OMCBM PI QMCB HOT LEG HV 0615 8887 M ~~ LOOP 716 m HV HV M (0621,1 0607 809 M r (020 0613 Y 06 2 02 QM llhl '3 M { SIS s' 12-L RCS HOT LEG COLD LEG l-1205-E6-002 LOOP 4 LOOP FT 2' (010 ) o Q 8' QMcB 0619 FIS M PI 7' QMCB b 7 0619 0611 5015 5017 8885 HV H HV 0619 Iv 34' 88llB 804 LOO 812 0619 0619 CVCS LETDOVN l-1205-P6-00 HEAT EXCHANGER 1 F (00p' HV ^ RESIDUAL HEAT j c-1M) 8812 SIS SAFETY a M INJECTION !I I REMOVAL PUMP FRDi CONTAINMENT 619 s, PUMP SUCTION FC EMERGENCY SUMP, j MCB 12' V i SEv. Om Tt DT Oer1 stSt EPTEM apres asww2 mPPR.3 araw. erwetS apuers v, 1 JC i v-e.-es as cve winer to imour scv i, -k[ Southern Company Services, Inc.FOR Southern Nuclear Operating Company ',~. l c5 Cl 'l *[ s ^ )' MB VDGTLE ELECTR ENERATING PLANT 'r= ' " '"c ,"v" sr t s os w-r -=. m en aw= m acam Av5 ,mc -.,,,,,u, PUMP INSERVICE TESTING LOOP ,.ui.m se t. no .s v. FOR RESIDUAL HEAT REMOVAL PUMP l-1205-P6-001 N/A N/A ISI-D-217 1 OF 1 6

O O O NOTE: THIS IS A SIMPLIFIED [M M FROM CONTAINMENT DIAGRAM USED TO DEPICT 0618Al 0618 FV 3, EMERGENCY SUMP A TEST CIRCUIT. REFER QMC 0610 TO THE PLID FOR DETAILS. 00 DMCB M pt OMCB 0618 HV 0614 8886 HS HV REFUELING VATER ^ HV FT 0606 0620 8 811 STORAGE TANK 809 M 0618 l (019 0612 0601 1-1204-T4-001 lik 0 SIS B* g{

  • }

r i COLD LEG hl FO 1-1205-E6-001 LOOP 8, 2, (]ED H e N FI Q TI PI OMCB HV 8884 0618 34, 870 A py CVCS CHARGING = r 4 0618 CVCS LETDOVN 1-1205-P6-001 812 V 'I PUMP SUCTION 7 HEAT EXCHANGER RESIDUAL HEAT 1 T HV HEADER M 8' 4 REMOVAL PUMP J L g 812 HV HV M li g, LC, ,LC RCS h T LEG m O l 8840 i

  • r, r,

- g FV 3' RCS 0611 (001 ) OMCB M pg OMCB 1 HOT LEG HV 0615 8887 M LDDP 716 ^ 06 7 l PI HV 809 M r (020 0602 702 M w 12' ES " COL LEG 1-12 2 r4 o LOOP 4 LOOP FT 2' (010 ) ' 'e 8' OMCB 0619 flS FV Q ] PI OMCB HV O 9 FV 881 B 804 O j g 0619 CVCS LETDOVN k HEAT EXCHANGER 1 (,00. U HV r 0 j g SIS SAFETY u l-1205-P6-002

L v 812

= M INJECTION I I RESIDUAL HEAT FRDi CONTAINMENT 619 e. PUMP SUCTION FC REMOVAL PUMP EMERGENCY SUMP, j MCB 12' .cy it cm3 scsc.,,rs>. -4 -2 => m. -s awers F 9-94-9. SEE Ws II3tK9 FIBt PET

  • I v-e+es me cvs wn.it in u. sour stv n JC

",l [ 'l*l '[! [ Southern Company Services, Inc.FOR Southern Nuclear Operating Company ') Et B V0GTLE ELECTR C ENERATING PLANT 'E5"' y ""c s s s st it m ..m e PUMP INSERVICE TESTING LOOP ^ ^ -120 -P6-002 N/A N/A ISI-D-218 1 DF l 6

~ l CS Pumps (1-1206-P6-001, & 002)' j System Function Containment spray limits the peak pressure in the containment to less than design pressure following a LOCA ~ or a main steam line break inside containment. Trisodium phosphate is mixed with recirculated spray water in the containment sump region for pH control and to enhance absorption of the airborne fission product iodine and to retain the iodine in the containment sump solution to limit calculated offsite doses to less than 10CFR100 limits. Quantity 2 i Type Horizontal, centrifugal j Manufacturer /Model Goulds Model 3415 Capacity 2600 gpm-l l Total Dynamic Head 450 ft. l ' Driver Type Westinghouse electric motor, Frame 5010S Horsepower 400 Speed 1777 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2 l Project Class 212 Outline Drawing IX6AD02-11 l-Instruction Book X6AD02-18 i l l Physical Location Aux Bldg, Level D, Rooms R-D76 & R-D77 j P&ID IX4DB131 Surveillance Procedure 14806-1 Pump Test Loop Diagrams . ISI-D-219 & ISI-D-220 Test Parameter Sheets Page 9-2 & 9-3 lO 9-1 Fev. 0

Test Parameter Table - Pump 1-1206-P6-001 (Figure ISI-D-219) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freu, J.D. No.(3) Range Req. Acc. Yalue Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver i Inlet Pressure Qtr PI-0972 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-0974 0-300 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(t) NA 12% APr .90 - l.10APr NA <.90 er >l.10APr NA (AP) Flowrate Qtr F1-0929 0-400 12% Qr NA NA NA Flowrate is set at reference value t (Q) gpm Vib. [ Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr-6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.

t

3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

9-2 Rev.0 l ~.. _ _. _ _ _ _ _ _..,.. _ _ _ _. _ _. _ _ _ _ _ _ _ _ _ _ _. -. _ _ _. _. _. m ..a. m

O O O Test Parameter Table - Pump 1-1206-P6-002 (Figure ISI-D-220) Instrumentation Utilized Ref. Acceptable Alert Action Entameter Irst Frey. I.D. No.(3) Range Req. Acc. Yalue Range Range Range Commeuts Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-0973 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-0975 0-300 i2% NA NA NA NA NA (Po) psig Differ. Pressu e Qtr NA(1) NA i2% APr .90 - 1.10APr NA < 90 or >l.10APr NA (AP) Flowrate Qtr F1-0929 0-400 2% Qr NA NA NA Flowrate is set at reference value (Q) gpr t Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr-6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shall in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

9-3 Rev.O

O O %) NOTE: THIS IS A SIMPLIFIED ,LC, p, DIAGRAM USED TO DEPICT r, A TEST CIRCUIT. REFER (006) TO THE P&ID FOR DETAILS. HV 9003 QMCB QMC'B 9001 HS 2' mr FROM CONTAINMENT HV TI PI 1094 9001A 0938 0974 PI 12' ENERGENCY SUMP FI 929 TO M 0972 CONTAINMENT - ?, I ] 12' SPRAY 8, l -n p a CONTAINMENT SPRAY J g --C PUMP S CONTAINMEN SPRAY ADDITIVE SPRAY EDUCTOR M 9017A TANK 1-1206-J6-001 g U 3* HV 3' HV 90 A. " -S 994 994 REFUELING VATER c 3 MCB MCB STORAGE TANK h 3' ] % 994 )% 9[4 2 09 1-1204-M-001 o S CONTAINMENT k 1,C, HV SPRAY EDUCTOR 10 9017B 1-1206-J6-002 15 2 MCB 9001B 3' ,QMCB M 9017B HV e h 9001B [CD 4 PI G 0 9 0973 o HV TO 8' ,5 9003P m m 7' 2' h CONTAINMENT e-SPRAY 1-1206-P6-002 l FROM CONTAINMENT PI CUNTAINMENT SPRAY m - 12-r, EMERGENCY SUMP 0975 PUMP ES 2* dT6h s., . s-e-an vs nacs em es, i e F-em

== cve won,ts a trema av rs - _iC a +am-e, nos vs weares a n. ems av r, -cC s m-,. m m usuv m.caso m Southern Company Services, inco rOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT E 5'*** UNIT I " ' ' * ' vs sc=1 .s,. a=rsus e. san PUMP INSERVICE TESTING LODP a. s,.wa. x, u FOR CONTAINMENT SPRAY PUMP 1-1206-P6-001 N/A N/A ISI-D-219 1 [F 1 3

.- - - -.=.~ -.~... - ~. - - -. ~. O J v s i NOTD THIS IS A SIMPLIFIED ,L C, p. A TEST CIRCUIT. REFER (006) DIAGRAM USED TO DEPICT r, TO THE P&ID FDR DETAILS. HV I 9003 OMCB QMCB b 9001 M FROM CONTAINMENT i HV TI PI 1094 r' 9001A 0938 0974 PI 12" EMERGENCY SUMP FI 929 TO M 0972 = i CONTAINMENT =,', } 12* i SPRAY 8, l r n 1-1206-P6-001 %'C3 n o CONTAINMENT SPRAY 8 g PUMP S 3 CONTAINMEN SPRAY ADDITIVE e SPRAY EDUCTOR 8 M 9017A TA W 1-1206-J6-001 2 S 994 994 f 3' HV 3' HV 90 A. REFUELING VATER c 3 CB MCB STORAGE TANK gh 3'] g ) M 994 2' 098 1-1204-T4-001 94 e l = CONTAINMENT h M HV i SPRAY EDUCTOR o 10 9017B (13_'2) r 1-1206-J6-002 1 MCB 9001B MCB HV M 9017 r 9001B g} s 1094 y pg C 0973 TD 8' 3 HV i 9003 m i h 2" CONTAINMENT r' SPRAY 1-1206-P6-002 l FROM CONTAINMENT PI CONTAINMENT SP' RAY 12' r' EMERGENCY SUMP 0975 PUMP I I ,L C, p. 1 dich =v-

== =

=

=== mum -2 .=, e e-em

n vi maan run m

-i r e

  • -sw ees vs u ems = ts.amm av w

> _c i

== cvs wts = u.amm av e -I ie-e-w m oss amm.. - oc Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT asino n mm. sec UNIT 1 c"* vs ~ PUMP INSERVICE TESTING LOOP ~ ua UEn i FOR CONTAINMENT SPRAY PUMP 1-1206-P6-002 N/A N/A ISI-D-220 1 (F 1 3 J

CVCS Pumps CENTRIFUGAL CHARGING PUMPS l (1-1208-P6-002, & 003) k-System Function The primary functions of the CVCS are to: ~ l Regulate reactor coolant chemistry for reactivity and corrosion control l Maintains the water level in the pressurizer of the RCS j Maintains seal-water injection flow to the reactor I e coolant pump ) Provide a means offilling, draining and pressure testing the RCS Provide injection flow to the RCS following actuation ofSIS Quantity 2 l Type Horizontal, centrifugal,11 itaIg i i . Manufacturer /Model Pacific, U 2-1/2 in., RL l Capacity 150 gpm Total Dynamic Head 5800 ft. Driver 1 Type Westinghouse electric motor ~ Horsepower 600 Speed 1800 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2 Project Class 212 { i Outline Drawing IX6AH02-101 Instruction Book IX6AH02-85 Physical Location Aux Bldg, Level C, Rooms R-Cl15 & R-C118 P&ID IX4DB116-2 Surveillance Procedure 1480~8-1 1 Pump Test Loop Diagrams ISI-D-221& ISI-D-222 i l Test Parameter Sheets Page 10-2 & 10-3 10-1 Rev.0

3 - (%)) f~( (d Test Parameter Table - Pump 1-1208-P6-0<)2 (Figure ISI-D-221) Instrumentation Utilized Ref. Acceptsble Alert Action Paramtitt Test Freq. I.D. NoJ3 n Range Ecsl. Acc. Yalue Bange Range Range Comments - F Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-8891 0-100 12% NA NA NA NA NA i (Pi) psig l Outlet Pressure Qtr PI-8472 0-4000 12% NA NA NA NA NA I i (Po) psig [ Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er >l.10APr NA (AP) Flowrate Qtr F1-10120 0-80 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm i Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s i N:t:s:

1. Differential pressure is calculated as, AP = Po - Pi f
2. Portable vibration instruments are utilized.

l

3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

i 10 -2 Rev.0

( ( V Test Parameter Table - Pump 1-1208-P6-003 (Figure ISI-D-222) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freo. I.D. No.(3) Range Req. Arc, Yalut Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-8892 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8473 0-4000 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr FI-10121 0-80 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA or >.325 in/s >.70 in/s (V)(4) Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

10 -3 Rev.0

~_ O ( ( %) O 3' SEAL VATER i 3' l@ 1 -120 - U 3' i P MP RVST SEALS 3' l 8110 VOLUME O g_gTgK RHT rt 3* j g L CVCS 1-1208-P6-001 3' 4 N N g3g REGENERATIVE Da0 W H POSITIVE DISPLACEMENT ll2B HEAT Fv G3D 6 8111A CHARGING PUMP 121 MCB EXCHANGER IN FT QMC 21 HS FI MCB 112C QMCB 8 2 273 485 g p3 @4. LD 12C 018 7 y 8891 CVCS $3 D 'M l , 6' O i 13 G 4, REACTOR ggg 1-1208-P6-002 COOLANT PUMP RHT SEALS MCB 1 g F CENTRIFUGAL H 10118 CHARGING PUMP 471 J LRHT F1 QMCB HST 'V NOTE: THIS IS A HS IUI I 47I 8 SIMPLIFIED DIAGRAM 485 3' PI USED TO DEPICT A TEST HV q 8473 274 PI MCB PI 0188 CIRCUIT. REFER TO THE 485 8892 8' M P&I.D. FOR DETAILS. 4 j ll; ) 6' GH9) n 1 O 1-1208-P6-003 RHT CENTRIFUGAL H LV 012 CHARGING PUMP 4 71 112E HV HV HS 803 803 1 G 508 4 71 FROM SIS BORON J LRHT MCB REFUELING INJECTION TANK RVST r, VA TER 1-1204-V6-001 STORAGE TANK -v- .m a

=-1

-u .-2 m. m. 9 FM Elt WS ISSLES FtR Pf7 fI a 7-e*-w

== cvs urnmn in in4 sam-e arv w JJC E "o_2 [ h Southern Company Services. Inc.FOR Southern Nuclear Operofing Company a E ~ 7rnY w~n U n m N.".n V0GTLE ELECTRIC GENERATING PLANT " " * * * " 8 "c s re+= m ox5 wn w s.. cama UNIT 1 g"a" ym, n PUMP INSERVICE TESTING LOOP -on. ar FOR CENTRIFUGAL CHARGING PUMP 1-1208-P6-002 N/A N/A ISI-D-221 1 IT I 5

I ~ I 's ) w 3' SEAL VATER LC 3' i l 1 -120 - - 3* MP RVST VOLUME i 3, SEALS g 8110 O OggigK hg C 1LT E = RHT rr h 3' CVCS 1-1208-P6-001 3' 4 112B REGENERATIVE ) ll DE} H POSITIVE DISPLACEMENT ll2B HS HEAT Fv G3D G23) BillA CHARGING PUMP EXCHANGER g$ 121 MCB FT QMC 0121 HS FI MCB 112C QMCB 3485 g 8 72 273 pg 018 7

4. LO 12C y

8891 --{$RJ hg ? Vi b

)

CVCS O , 6' 013 REACTOR G 4, g 1-1208-P6-002 CDDLANT PUMP RHT SEALS MCB 1 G FD CENTRIFUGAL H 10118 CHARGING PUMP 471 J LRHT FI QMCB V HS NOTE: THIS IS A HS 10121 SIMPLIFIED DIAGRAM 485 3, PI g3 4 71 8-112D USED TO DEPICT A TEST HV q 8473 274 PI MCB pl CIRCUIT. REFER TO THE 485 0188 M-g I 8892 P&I.D. FOR DETAILS. q af " ili I ) 6' GH9) O ~ 1-1208-P6-003 RHT CENTRIFUGAL H LV 1012 CHARGING PUMP 4 71 112E HV HV HS gy 803 803B-508 4 71 FROM 2 J LRHT p MCB REFUELING SIS BORON INJECTION TANK RVST r, VATER 1-1204-V6-001 STORAGE TANK uv.

== e, o., ww - -.2 -m -m m. -s

====s ,. m er m aac

7. [

.",",'Z.",,,,, Southern Company Services. Inc.rOR Southern Nuclear Operating Company "E Z Z", 7,,7.".n".,,,*,",,, C"n VDGTLE ELECTRIC GENERATING PLANT==8 ""C s se+*

== zwJ .s. s =4en UNIT 1 m _ PUMP INSERVICE TESTING LOOP

=

iar av. FOR CENTRIFUGAL CHARGING PUMP 1-1208-P6-003 N/A N/A ISI-D-222 1 IF 1 5

l BORIC ACID TRANSFER PUMPS l (1-1208-P6-006 & 007) System Function Provides boric acid to the CVCS for use in RCS inventory control and makeup to systems requiring reactor grade ) borated water. The boric acid transfer system also provides boric acid for emergency boration of the RCS. Quantity 2 Type Canned motor Manufacturer /Model Chempump Model GVH-1K Design Flowrate 75 gpm l Design Head 235 ft. l Driver Type Electric motor kW 15.5 i Speed 3450 rpm ) Power Supply 4160V,60 Hz,3 phase Code Class 3 'O Project Class 313 Outline Drawing IX6AH02-45 j Instruction Book 2X6AA07-10 Physical Location Aux Bldg, Level D P&ID 1X4DB118 Surveillance Procedure 14811-1 Pump Test Loop Diagrams ISI-D-228& ISI-D-229 Test Parameter Sheets Page 11-2 & 11-3 O 11 - 1 Rev.0 4

Test Parameter Table - Pump 1-1208-P6-006 (Figure ISI-D-228) Instrumentation Utilized Ref. Acceptable Alert Action j Parameter Test Freq. I.D. NoJ3) Range Req. Acc. Value Range Range Range Commenh Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-10115 -15 to +15 2% NA NA NA NA Relief Request RR-P-1 (Pi) psig Outlet Pressure Qtr Pl-Oll3 0-160 12% NA NA NA NA NA i (Po) psig DilTer. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er >l.10APr NA (AP) Flowrate Qtr FI-40001 0-100 t2% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA 15% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Nstes:

1. Differential pressure is calculated as, AP = Po - Pi
1. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing ho'ising and in the axial direction on each accessible thnist bearing housing.

11 - 2 Rev.0

'\\ f') p %./ Q ~ Test Parameter Table - Pump 1-1208-P6-007 (Figure ISI-D-229) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. NoJ3) Range Req. Acc. Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-10l l6 -15 to +15 12% NA NA NA NA Relief Request RR-P-1 (Pi) psig Outlet Pressure Qtr PI-0114 0-160 i2% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10aPr NA <.90 or >l.10APr NA (AP) Flowrate Qtr F1-40001 0-100 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration inst uments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shcft in two orthogonal directions on each accessible pump-bearing housing and in the axial s

direction on each accessible thrust bearing housing. 11 - 3 Rev.0

f D V} (V V NOTE THIS IS A V SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TD 3 7 PLI.D. IX4DB118 FOR (x-Ann) jg DETAILS. FROM BRS RECYCLE LD LD TO BDRIC EVAPORATOR g ACID 2' X X e @ FILTER 011 eZ ll! ir m (1 (1 i D U 1h*2 = ;;; 2' = 1 e am e i BORIC ACID 000 TRANSFER PUMP LC i BORIC ACID l-1208-P6-007 2' a BORIC ACID FILTER BYPASS 2* STORAGE TANK SEE ISI-D-229 TD BORIC ACID BLENDER 7' 1-1208-T4-003 O 3' FU,TURE DMCB NE'U 6 J L I 3' PP 113 011 LO ', C N Z LO La = 2 > (0 1, 3 X = e e Mc, e 3 m e S{ [ t 3][G l-1 8-P6g06 SAMPLE B Y ACID TRANSFER PUMPS TO UNIT 2 BORIC TRANSFER PUMP + 7 U- .c" c5i) J7c "~ ~ ~ ~ ~ vs unasrm m i av ,- -es ces vs asers ri=== WLV MB Z 2, E h".".","."., Southern Company Services. inc. FOR Southern Nuclear Operating Company VDGTLE ELECTR ENERATING PLANT "_5 = = = ""' =

==z com m e eimari PUMP INSERVICE TESTING LOOP FOR r=ana seaws.i - ours arv. BORIC ACID TRANSFER PUMP 1-1208-P6-005 N/A N/A ISI-D-228 1 IF 1 3

O O O NOTE THIS IS A v SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TD F PLI.D. IX4DBil8 FOR (X-800) Jk DETAILS. FROM BRS RECYCLE LO LO 10 BORIC EVAPORATOR b, X X F ER GL"D GB7) '011 2 1 X lll U y

[-

'o m (1 L1 i P LO 2' LO 14H: p.: lil M Dec =X 1 e am m I BORIC ACID 000 TRANSFER PUMP LC BORIC ACID FILTER BYPASS _ BORIC ACID l-1208-P6-006 2* n STORAGE TANK SEE ISI-D-228 7' TO BORIC ACID BLENDER 1-1208-T4-003 O 3' FUTURE OMC eM'o y J k I 11 4 3' PP on to .C N X l 'O

3.>. (O 1i 3'

X i e e 60~ m 3' G8a GTA S$[ 5 3][G 2:! l-th8-P6-007 SAMPLE B C Y ACID TRANSFER PUMPS TO UNIT 2 BORIC TRANSFER PUMP uv. se av oari mwanem mu

=

mu me mas ames a w-en* nac vs naza nst est i ist CVD _lJC i =-*-se ese we aesce rr esem VLV MB Se N3 mE Southern Company Services, Inc.FOR Southern Nuclear Operating Company 3 VOGTLE ELECTRIC GENERATING PLANT =*** *

    • =

e UNIT 1 ' " " ' " v5 EA1 am CENTDEAe De Isti PUMP INSERVICE TESTING LOOP FOR emana en.w =m meu =v. BORIC ACID TRANSFER PUMP 1-1208-P6-007 N/A N/A ISI-D-229 1 IF 1 3

I i AFW Pumps (1-1302-P4-001,002 & 003) System Functior Supply water to the steam generators whenever the reactor v coolant temperature is above 350'F and the main feedwater system is not in operation, i.e., during startup, cooldown, or emergency conditions resulting in a loss of main feedwater. Automatically provides feedwater for the removal of reactor core decay heat following a loss of main feedwater. This prevents damage to the reactor core until the reactor coolant temperature is brought from a hot standby condition to the point at which RHR may be placed into operation. i AFW mpplies feedwater to the steam generators at a flowrate sufficient to support normal low-power transients such as startup, cooldown, and hot standby. l Turbine Driven AFW Pumo (1-1302-P4-001) l Quantity } Type Horizontal, centrifugal,5 stage, split-case Manufacturer /Model Ingersoll-Rand, Model 6HMTA Capacity 1175 gpm Total Dynamic Head 3500 ft. Driver Type Terry Turbine, Model GS-2N, non-condensing, single-stage, mechanical drive Horsepower 1603 Speed 4250 rpm Power Supply Steam Code Class 3 Project Class 313 Outline Drawing IX4AF03-83 Instruction Book IX4AF03-20033 12 - 1 Rev.O

Turbine Driven AFW Pumo (1-1302-P4-001)(conti Physical Location AFW pump house O ~ IX4DB161-2 P&ID Surveillance Procedure 14810-1 Pump Test Loop Diagrams ISI-D-223 Test Parameter Sheets Page 12-4 i l l lO l l l i l l l l i O 12 - 2 Rev.0

. -.. ~ - - Motor-Driven AFW Pumos (1-1302-P4-002 & 003) Quantity 2 9~ Type Horizontal, centrifugal, 6 stage, split-case i Manufacturer /Model Ingersoll-Rand, Model 4HMTB Design Flowrate 630 gpm Total Dynamic Head 3500 ft. Driver Type Westinghouse electric motor, LLD 5810 H l Horsepower 900 l Speed 3600 rpm Power Supply 4160V,60 Hz,3 phase l Code Class 3 Project Class 313 Outline Drawing IX4AF03-81 Instruction Book IX4AF03-20032 lO Physical Location AFW pump house P&tD IX4DB161-2 Surveillane Procedure 14807-1 1 Pump Test Loop Diagrams ISI-D-224& ISI-D-225 j l 1 Test Parameter Sheets Page 12-5 & 12-6 ) i d i i r I 12 - 3 Rev.0 l i

o o Test Parameter Table - Pump 1-1302-P4-001 (Figure ISI-D-223) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. NoJ3) Range Req. Arc. Yalue Range Range Range Comments i Speed l (N) Qtr SI-15109A 0-6000 12% Nr NA NA NA Speed is set to reference value Inlet Pressure Qtr PI-5110A 0-30 12% NA NA NA NA NA ( (Pi) psig t Outlet Pressure Qtr PI-5107A 0-2000 12% NA NA NA NA NA (Po) psi Differ. 1 Pressure Qtr NA(I) NA 2% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr F1-15100 0-200 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr 5 2.5Vr - > 2.5Vr - 6Vr >6Vr or NA i (V)(4) or >.325 in/s >.70in/s t Notes:

1. DifTeremial pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

l 12 - 4 Rev.0

r n (s) Test Parameter Table - Pump 1-1302-P4-002 (Figure ISI-D-224) Instrumentation Utilized Ref. Acceptable Alert Action l Earamcler Test Frea. I.D. No13) Range Ben. Arc. V_ sinc Range Range Range Comments t i Speed (N) NA NA NA NA NA NA NA NA Constant speed driver i Inlet Pressure Qtr PI-5128A 0-30 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-5140A 0-2000 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr F1-15101 0-200 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm ( Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s i Notes:

1. DifTerential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

12 - 5 Rev.O f t t t

( ) O) C)\\ N._/ L. 4* I CONDENSATE CONDENSATE TE 15 9 5106 'I STORAGE TANK STORAGE TANK 5175 FRON MAIN - I NH NU 1-1302-V4-002 1-1302-V4-001 sy g (Opg) 0 15133 QMCB M 3g g3 5' I HV 5109 106A 5107 o-- 3090 5110A MCB J GMCB ~ ' ' ' 0 l I LD E i 6' N 3[-@O GIT) 6 HV AUX FEEDVATER TURBINE DRIVEN i b HV 5093 PUM. P TURBINE 1-130g-P4-001 N rd NOTE: THIS IS A 5113 1-1302-P4-0DI-K01. TO FEEDVATER [. SIMPLIFIED DIAGRAM I dh ATMOSPHERE t' UMP FV USED TO DEPICT A TEST I 10' Y MCB 5154 CIRCUIT. REFER TO THE I M QMCB M G' P&I.D. FOR DETAILS. r D 130A 140 g, ; HYDRAZINE AMMDMA & HV ~~a HV 128 MCB v 3 [_ 5098 5094 1 6 f (, lr N y 8* 8' i LD (U5g) 1-130g4-002 g gy 5118 FE g TER 3 ~ 2' FV ET) 8 5155 2,, A' QMCB o OMC M 2~ HV 5092-- HV OMCB 131A (5141A} ( l I -_3 5095 y 5129 p j, HV 3]_ 5099 II 8' [, ltW k LD HV LD 1-1302-P4-003 GUT) i 5119 AUX @ (052) FEEDVATER 8, 8, PUMP ~

    • Pea appea m*

'=== N PIT II l y ee a uninimma-,av JJC 1", Q e =2

==aw m. = =3 DMs Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRgENERATING PLANT nea n sac PUMP INSERVICE TESTING LOOP ~ aa. U .a. e FOR AUXILLARY FEEDVATER PUMP 1-1302-P4-001 N/A N/A ISI-D-223 iTI 2

CT ( U V (v) M II 2.5' PV HV NM CONDENSATE CONDENSATE TE 15129 5106 MIl STORAGE TANK STORAGE TANK 5175 FROM MAIN I 1-1302-V4-002 l-1302-V4-001 MM UMM I gy gg3)(ggg) D 15133 OMCB SI HS g 2'5'!! HV 5109 106A 5107 6 - 5090 5110A MCB l LO I 6' m I N s s J = 9 HV AUX FEEDVATER TURBINE DRIVEN y b 1-hoY-P NkkOf N NDE THIS IS A HV 5093 ti[ 5113 TO FEEDVATE [- X s__ SIMPLIFIED DIAGRAM If ATMOSPHERE PUMP FV USED TO DEPICT A TEST 10, MCB 5154 CIRCUIT. REFER TO THE i OMCB H 'D g l3 A ^ S] AMMONIA 8. HV S HV 128 MCB HYDRAZINE g[_5098 5094 g g l[8' 09 4, e 8' ll: N y _s_ h HV i U FE g TER 3 2' 5118 8" QMCB QMCB M 2~ HV D HV 5095 HV LO 1-02-P4-003 5119 AUX G FEEDVATER 8, 8, PUMP ,EW. EM M M1 m3cygpygge appgj sppeg appg3 apea4 APPt 3 M3taPK$ e s-a-= nas vs num run m ti i 1-e++. en wmns = imma4 =v i. Jac ~ ~~"~ Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT==* " n=*

  • ac UNIT 1

=== vs ~ ~ PUMP INSERVICE TESTING LOOP 52Y m, a. FOR AUXILLARY FEEDVATER PUMP j 1-1302-P4-002 N/A N/A ISl-D-224 1 IT 1 2

[] U {V (V N 'N, Ap a.s-N I 2.5

  • CONDENSATE CONDENSATE TC 15 29 510 l

STORAGE TANK STORAGE TANK 5175 FRDN MAIN I NAMUSEM 101 1-1302-V4-002 1-1302-V4-001 sy ggg)g l 0 15133 gg gg -DMCB 'M 2.5'!! HV 5109 106A 5107 o-- 5090 5110A MCB J GMCB /, R l 0% i 6' ru i LO a 'N am e 3[-@0 HV AUX FEEDVATER TURBINE DRIVEN b b PUMP TURBIN l-1302-P4-001 N (V NGTO THIS IS A HV 5093 1-1302-P4-001 EK01'TD FEKD ATER [- 5113 SIMPLIFIED DIAGRAM M ATMOSPHERE RUMP ry USED TO DEPICT A TEST I GMCB M 7' D OR D TAI. r p 130A 140 mj AMMONIA & HV ~~o HV 128 MCB 8 HYDRAZINE ' 5094 6 g 6 O f_ 5098 8' e' lIl N LD (05E) 1-130g4-002 g HV 5118 FEggTER e-2* N g. 5155 ? l S' 3 QMC HV QMC HS pg ,2' 5092--S 5095 HV 131A 5141A ( l U 5129 s 6 0 O_ HV LO j{ 1-02-P4-003 5119 AUX g, 8, FEEDVATER s PUMP "v-we MSCRIPTEBe O S 4 4-94 g;g 4M4 TV I6 B = Southern Company Services, Inc.roR Southern Nuclear Operating Company VDGTLE ELECTR ENERATING PLANT Q88a PUMP INSERVICE TESTING LOOP ~ .au. oui uv. FOR AuxlLLARY FEEDVATER PUMP 1-1302-P4-003 N/A N/A ISI 225 1T1 2

ESF Pumps \\ i (1-1592-P7-001, & 002) O System Function i ~ Durmg normal operation, the ESF chilled-water system is in standby mode; it is activated during emergency conditions upon receipt of a safety injection signal, containment ventilation isolation, or control room isolation signal. The ESF chilled-water system serves air handling units located in the safety-related areas of the plant to ensure the l integrity of the cooling system during plant emergency situation. l l Quantity 2 1 Type Centrifugal Manufacturer Goulds Capacity 600 gpm Total Dynamic Head 125 ft. Driver. l Type Westinghouse electric motor i Horsepower 30 iO sPeea tioo rP-Power Supply 480V,60 Hz,3 phase Code Class 3 l Project Class 313 Outline Drawing IX4AJ05-27 Instmetion Book AX4AJ05-86 Physical Location Control Bldg, EL 260 ft., Rooms R-313 & R320 i P&ID IX4DB221 Surveillance Procedure 14809-1 l Pump Test Loop Diagrams ISI-D-226 & ISI-D-227 l Test Parameter Sheets Page 13-2 & 13-3 i l 4 13 - 1 Rev.0 -nt

~ i Test Parameter Table - Pump I-1592-P7-001 (Figure ISI-D-226) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea. LD. No.(3) Bange Req. Ace. Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver i Inlet Pressure Qtr PI-22410 0-30 12% NA NA NA NA NA (Pi) psig r Outlet f Pressure Qtr PI-22414 0-200 12% NA NA NA NA NA i (Po) psig i Differ. Pressure Qtr NA(1) NA 2% APr .90 - 1.10APr NA <.90 or >l.10APr NA k (AP) i Flowrate Qtr FI-22425 0-750 12% Qr NA NA NA Flowrate is set at reference value i (Q) gpm I Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s l [ Notes: r 6

1. Differential pressure is calculated as, AP = Po - Pi r
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

f j 13 - 2 Rev.0 l i i I i I

s i Test Parameter Table - Pump 1-1592-P7-002 (Figure ISI-D-227) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. No.(3) Range Reg. Acc. Value Range Rance Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-22411 0-30 i2% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-22415 0-200 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr FI-22426 0-750 i2% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr-6Vr >6Vror NA or >.325 in/s >.70 in/s (V)(4) Notes:

1. DifTerential pressu.~ is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

13 - 3 Rev.0

( J' v V NOTE

1. THIS IS A SIMPLIFIED EXPANSION DIAGRAM USED TO DEPICT TANK A TEST CIRCUIT. REFER HVC S

1-1592-T7-001 TO THE P8.ID FOR 2240 IP2412 DETAILS. C 2240 I, (

2. VALVE INTERNALS REMOVED PER DCP IA

} pO. 90-VIN 0067-0-1 f . FEED POT. 242 CHEMICAL SDA TI FI D mgamn,, t S N2 PI HV TI 243 ' 244 (U5tD GMD pI 2241 e 2244 2241 22410 3J L @ 3, 1/2" l O N LC N l EVAP. l M @ CB ESF CHILLER k 1-1592-C 7-001-000 h, I' CB ESF CHILLED 2" 6' n ATER 1P 5 VATER PUMP r LC HV odL 1-1592-P7-001-000 240 PROJ. CLASS 313 10' i t 10* 10' ~ TRAIN 'A' 6' CDOLING COILS ? =~.

== s,

== rs

-u w., -s 9 +H BW WS I3$tES FIR PST I we+= ews woms a u.saans arv n - JC i7 E C,,1" Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT==* " =

  • a UNIT I o=*

vs PUMP INSERVICE TESTING LOOP $ $ 2 ' FOR CB ESF CHILLED WeiCo PUMP TRAIN 'A' 1-1592-F 7-001-000 N/A N/A ISI-D-226 1 IT I 3

( + v v u> l NOTE: 1. THIS IS A SIMPLIFIED EXPANSION DIAGRAM USED TO DEPICT TANK A TEST CIRCUIT. REFER HVC S 1-1592-T7-002 TO THE P8.ID FOR 2240 2413 DETAILS. C

2. VALVE INTERNALS 22401 l'

REMOVED PER DCP CHEMICAL j {n 90-VIN 0067-0-I g FEED PDT. pg f N CHEMICAL SDB TI FI D FEED PDT. 243 ' 242 7' s h mn. C9 1 G G PI h 22 1 P 44 d 1 22411 &L M, 1/2" LC

  1. 1 I

IEVAP. l N sm "N 6 (2U7) CB ESF CHILLED hkh" VATER CB ESF CHILLED ~ ~ ~ 1-2' 6* m )( [P VATER PUMP LC HV 3 1-1592-P7-002-000 dk L1 240 PROJ. CLASS 313 10' I ' 10'h Y 10 D b* TRAIN "B. 6* COOLING COILS Ev. SAM BT Det*3 M EWIPYE3e apetJ APPt3 mPpg3 appts appt 3 h3 a 7-**

== evs urn.ns = in ams arv is _ _C M NS "(( 7 Southern Company Services, Inc. FOR Southern Nucisar Operating Cornpany .,v VDGTLE ELECTRIC GENERATING PLANT==* " 5"' "58 UNIT 1 ""' v5 nau amneens a man PUMP INSERVICE TESTING LOOP ua v .a. = v. FOR CB ESF CHILLED VATER PUMP TRAIN 'B' 1-1592-P7-002-000 N/A N/A ISI-D-227 I IT I 3

O O O I t VEGP-2 PUMP TEST TABLE i Nucle:.r Service Cooling Water - System 1202 Measured Per--- :-. A Fr-v LD. Number CC/PC PalD-Sheet No. Coord. _ Der 8ation h g Q y. E RIVRemuth (asial (mull (aniel ikksi taunl 2-1202-P4-001 3D13 2X4DB113-1 C-8 NSCW Pump Q1R QTR Q1R QIR NA RR-P-2 2-1202-P4-002 3D13 2X4DB133-2 C-8 NSCW Pump QTR Q1R QTR QTR NA RR-P-2 2-1202-P4-003 3S13 2X4DB133-1 C-5 NSCW Pump QTR QTR Q1R QTR NA ~ RR-P-2 2-1202-P4-004 3 S 13 2X4DB133-2 C-5 NSCW Pump Q1R QTR QIR Q1R NA RR-P-2 2-1202-P4-005 3B13 2X4DB133-1 C-7 NSCW Pump QTR QTR QTR QTR NA RR-P-2 i 2-1202-P4 006 3813 2X4DB133-2 C-7 NSCW Pump Q1R Q1R Q1R QTR NA RR-P-2 2-1202-P4@7 3013 2X4DB133-1 C4 NSCW Transfer Pump Q1R Q1R QTR QIR NA RR-P-2 2-1202-P4-008 3B13 2X4DB133-2 C-6 NSCWTransfer Pump QTR QIR QTR QTR NA RR-P-2 4 t Test Frequency: QTR= Quarterly Pump Test t ? l i \\ r 4 14 - 1 Rev.0 u ...-m..- m.a --s __-,-=.-% S ++--wa e-

~.. O O O VEGP-2 PUMP TEST TABLE Component Cooling Water-System 1203 Measured Parameters & Freemency LD. Number CC/PC P&ID-Sheet No.

Coord, Description Bt AE Q

V N RR/ Remarks i (a!ial fa 0 faunl Gaksl framil 2-1203-P4-001 3/313 2X4DB136 G-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-002 3/313 2X4DB136 D-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-003 3/313 2X4DB136 G-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-004 3/313 2X4DB136 C-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-005 3/313 2X4DB136 F-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 2-1203-P4-006 3/313 2X4DB136 B-4 CCW Pump QTR QTR QTR QTR NA RR-P-2 Test Freepsency: QTR = Qua.terly Pump Test L I L 14 - 2 Rev.0

VEGP-2 PUMP TEST TABLE Safety Injection - System 1204 Measured Parameters & Freenesev LD. NTmber ((JPC PAID-Sbret No. Coord. Description h AP Q V _N_ RR/ Remarks (asis) (s!Q (sand hi fouel i b 2-1204-P6@3 2/212 2X4DB121 E-3 SI Pump QTR QTR QTR QTR NA RR-P-2 2-1204-P6-004 2/212 2X4DB121 C-3 SI Pump QTR QTR QTR QTR NA RR-P-2 i Test Frequency: QTR = Quarterly Pump Test l t I I i 14 - 3 Rev.0

O O O VEGP-2 PUMP TEST TABLE Residual Heat Removal-System 1205 Measured Parameters & Freemency LD. Number CC/PC P&ID-Sheet No. Coord. Description to AE Q E N. RR/ Remarks (adal fa!!! (smal Gaksi Ltund 2-1205-P6@l 2/212 2X4DB122 G-4 RHR Pump QTR QTR QTR QTR NA RR-P-2 2-1205-P6 @ 2 2/212 2X4DB122 D-4 RHR Pump QTR QTR QTR QTR NA RR-P-2 i Test Frequency: QTR = Quarterly Pump Test 14 - 4 Rev.0

O O O VEGP-2 PUMP TEST TABLE Contstment Spray - System 1206 r Measured Parnaseters & Freemency LS. N aber CQ/PC P&ID-Sheet No. Coord. Description Po R _Q V N RR/ Remarks (esial (e!!1 (and (W=c) (mal 1 2-12 % % 001 2/212 2X4DB131 G-4 CS Pump QTR QTR QTR QTR NA RR-P-2 2-12%P6-002 2/212 2X4DB131 C-4 CS Pump QTR QTR QTR QTR NA RR-P-2 l l Test Frequency: QTR = Quarterly Pump Test I t r i l i i 14 - 5 Rev.0 m

O O O VEGP-2 PUMP TEST TABLE l Chemical & Volume Control-System 1208 f Measured Parameters & Freemency I LD. Number CC/PC P&ID-Sheet No. Coord. Description Po AE Q V-E RR/ Remarks I fa!!al fasil (sanal (Wwel Qaud 2-1208-P6-002 2/212 2X4DBII6-2 G-4 CVCS Centnfugal QTR QTR QTR QTR NA RR-P-2 Charging Pump s 2-1208-P6403 2/212 2X4DBII6-2 C-4 CVCS Centrifugal QTR QTR QTR. QTR NA RR-P-2 l 1 Charging Pump 2-1208-P6-006 3/313 2X4DBil8 D-4 CVCS Boric Acid QTR QTR QTR QTR NA RR-P-1, RR-P-2 Transfer Pump 2-1208-P6407 3/313 2X4DBil8 B-4 CVCS Boric Acid QTR QTR QTR QTR NA R. P-1, RR-P-2 Transfer Pump Test Frequency: QTR = Quarterly Pump Test i I 14 - 6 Rev.O

O O O i VEGP-2 PUMP TEST TABLE i Armili;ry Feedwater -System 1302 i Measured Parameters & Freemency LD. Number CC/PC P&ID-Sheet No. Coord. Descdotion Po R Q V N RR/ Remarks fadal te!Q fand (W=) trustl 2-1302-P4-001 3/313 2X4DB161-2 F-6 AFW Pump QTR QTR QTR Q1R NA RR-P-2 I Turbine Driven t 2-1302-P4-002 3/313 2X4DB161-2 D-6 AFW Pump Q1R Q1R Q1R Q1R NA RR-P-2 ) Motor Driven 2-1302-P4-003 D 3 2X4DB161-2 B-6 AFW Pump Q1R QTR QTR Q1R NA RR-P-2 Motor Driven i i I Test Frequency: QTR = Quarterly Pump Test i f i t 14 - 7 Rev.0

[ VEGP-2 PUMP TEST TABLE Sdety Related (ESF) Chillers - Systens 1592 Measured Parameters & Frea=*=ev LD. Number CC/PQ P&ID-Sheet No. Coord. Descdotion Po AE Q V N RR/ Remarks (eds! (ann (cral h) Its!n1 2-1592-P7-001 3/313 2X4DB221 F-5 ESF Chilled Water QTR QTR QTR QTR NA RR-P-2 Pump f 2-1592-P7 002 3/313 2X4DB221 C-5 ESF Chilled Water QTR Q1R QTR QTR NA RR-P-2 { i Pump Test Frequency: QTR = Quarterly Pump Test t i l i i 14 - 8 Rev.0

j-NSCW Pumps (2-1202-P4-001, 002, 003, 004, 005, & 006) i i r System Function Provide cooling water for the containment coolers, control building essential chiller condensers, various engineered safety feature pump motor and lube oil coolers, and the component cooling water and auxiliary component cooling water diesel generator jacket water heat exchangers and transfers the heat removed to the ultimate heat sink. Quantity 6 Type Vertical Line Shaft,2 stage, selflubricated Manufacturer /Model BinghamMdlamette/18x27B VCM Rated Capacity 8600 gpm (each) Rated TotalDynamic Head 230 feet Driver Type Electric Motor Horsepower 700 Speed 1180 rpm Power Supply O 4160V,60 Hz,3 phase Code Class 3 Project Class 313 Outline Drawing 2X4AF02-33 i Instmetion Book 2X4AF02-94 Physical Location NSCW Pump House P&ID 2X4DB133-1, -2 Surveillance Procedure 14802-2 Pump Test Loop Diagrams ISI-D-250 through ISI-D-255 1 Test Parameter Sheets Page 15-3 through 15-8 O 15 - 1 Rev.O

NSCW Transfer Pumps j (2-1202-P4-007, 008) { i System Function Provides capability to transfer water between cooling tower ) basins. J Quantity 2 j Type Vertical Line Shaft,2 stage, selflubricated i Manufacturer /Model Bingham-Willamette/18x12A VCM Rated Capacity 600 gpm (each) l Rated Total Dynamic Head 110 feet Driver Type Electric Motor j Horsepower 30 j Speed 1765 rpm i Power Supply 480V,60 Hz,3 phase l Code Class 3 !{p Project Class 313 s j I Outline Drawing 2X4AF02-136 i i Instruction Book 2X4AF02-96 l Physical Location NSCW Pump House i P&ID 2X4DB133-1, -2 i Surveillance Procedure 14801-2 Pump Test Loop Diagrams ISI-D-256 and ISI-D-257 Test Parameter Sheet Page 15-9 and 15-10 0 15 - 2 Rev.0

O O 3 Test Parameter Table - Pump 2-1202-P4-001 (Figure ISI-D-250) ~ Instrumentation Utilized Ref. Acceptable Alert Action Earameter Test Frea. I.D. NoJ4) Range Req Acc. Value RanFe Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet-Pressure Qtr LI-1606 NA (1) NA NA NA NA Measure basin level (Pi) Outlet Pressure Qtr PI-2148 0-200 12% NA NA NA NA NA i (Po) psig DifTer-Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr FI-l 1760 0-15000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA 15% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s i Notes: i

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, w hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

j i I 15 - 3 Rev.0 i r

O O O i Test Parameter Table - Pump 2-1202-P4-002 (Figure ISI-D-251) Instrumentation Utilized Ref. Acceptable Alert Action Parameicr Test Frea, I.D. No14) Range Reo. Acc. Value Range Range Range Cnements Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1607 NA (1) NA NA NA NA Measure basin level (Pi) } l Outlet Pressure Qtr PI-2149 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr FI-I 1763 0-15000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA t (V)(5) or >.325 in/s >.70 in/s Notes:

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

i 15 - 4 Rev.0 i

O O O Test Parameter Table - Pump 2-1202-P4-003 (Figure ISI-D-252) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea. I.D. No.(4) Range Rea. Acc. Value Ranee Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1606 NA (1) NA NA. NA NA Measure basin level h (Pi) Outlet Pressure Qtr PI-2152 0-200 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr (2) NA 2% APr .95 - 1.10APr .93 <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr FI-I1762 0-15000 12% Qr NA NA -NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA i5% Vr 5; 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s Notes:

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

15-5 Rev.0 .I

O O O Test Parameter Table - Pump 2-1202-P4-004 (Figure ISI-D-253) Instrumentation Utilized Ref. Acceptable Alert Action Parametgr Test Freq. I.D. No14) Range Reo. Acc. Value Bange Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr LI-1607 NA (1) NA NA NA NA Measure basin level (Pi) Outlet Pressure Qtr PI-2153 0-200 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr FI-l 1765 0-15000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s Notes:

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instmmentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

15 - 6 Rev.0

(3 G Test Parameter Table - Pump 2-1202-P4-005 (Figure ISI-D-254) Instrumentation U83H=d Ref. Acceptable Alert Action e Paramelgt Test Frea. LD. No.(4) Bange Erg. Acc. Yalue Range Ranee Bangt Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver i Inlet Pressure Qtr LI-1606 NA (1) NA NA. NA NA Measure basin level (Pi) v Outlet l Pressure Qtr PI-2150 0-200 12% NA NA NA NA NA i (Po) psig l [ Differ. Pressure Qtr (2) NA 12% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA j i (AP) L Flowrate Qtr F1-11761 0-15000 i2% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s [ t I t N:tes: c I. Basin level indicator is utilized to determine level in feet. (

2. Differentishressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portal % vibrmbn instruments are utilized.
4. At '.ne discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

15 - 7 Rev.0 j l


--.-- s c

w~

O Test Parameter Table - Pump 2-1202-P4-006 (Figure ISI-D-255) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. NoJ4) Range Req. Acc. Value Range Range Pange Comments 4 Speed t (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr LI-1607 NA (1) NA NA NA NA Measure basin level (Pi) i Outlet Pressure Qtr PI-2151 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr (2) NA i2% APr .95 - 1.10APr .93 - <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr FI-I1764 0-15000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA i5%. Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s Notes:

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, u hich meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one ofwhich is the axial direction.

i t 15 - 8 Rev.O \\ + , -. + n

O F O Test Parameter Table - Pump 2-1202-P4-007 (Figure ISI-D-256) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea. I.D. No.f41 Bange Rea. Acc. Yalue Rasse Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr LI-1606 NA (1) NA NA M *_ NA Measure basin level (Pi) Outlet Pressure Qtr PI-2154 0-100 12% NA NA NA NA NA (Po) psig i Differ. Pressure Qtr (2) NA 2% APr .95 - 1.10APr .93 <.95APr <.93 or >l.10APr NA (AP) Flowrate Qtr F1-2156 0-1000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (3) NA 15% Vr s; 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s N:tes: i

1. Basin level indicator is utilized to determine level in feet.
2. DifTerential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

15 - 9 Rev.0 .L T

_ _ _ _ _ _ ~.. -... O O Test Parameter Table - Pump 2-1202-P4-008 (Figure ISI-D-257) Instrumentation Utilized Ref. Acceptable Alert Action i Paramet-r Test Freq. I.D. No.f 4) RanFe Req. Ash Yalu Range Ranee Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver l Inlet Pressure Qtr L1-1607 NA (1) NA NA NA NA Measure basin level (Pi) Outlet Pressure Qtr PI-2155 0-100 12% NA NA NA NA NA i (Po) psig Differ. t Pressure Qtr (2) NA i2% APr .95 - 1.10.1Pr .93 <.95APr <.93 or >l.103Pr NA l (AP) Flowrate Qtr FI-2157 0-1000 12% Qr NA NA NA Flowrate is set at reference value l (Q) gpm Vib. Amp. Qtr (3) NA 5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(5) or >.325 in/s >.70 in/s Notes:

1. Basin level indicator is utilized to determine level in feet.
2. Differential pressure is calculated using basin level (to determine suction head) and outlet pressure.
3. Portable vibration instruments are utilized.
4. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
5. Measurements are taken on the upper motor-bearing housing in three orthogonal directions, one of which is the axial direction.

15 - 10 Rev.O k L .--l

O O O NOTE THIS IA A SIMPLIFIED DIAGRAM CV USED TO DEPICT A TEST CIRCUIT. 9446 M[><]H/' ACID ADDITION REFER TO P&lD FOR DETAILS. (155) (040) N BLIND FLANGE N h 142 FC OVDOVN 7 ) I / X ylSPERSANT ADDITION s 3' '048) yy y 4' a4-h [6' 18' S g DMCB g DMCB QMCB 1602A 1608A 1634 18' 18" I g l l 11761 l 11762 l 11760 l 1668 NSCVS . COMPONENTS 24 PDI PI PDI PI PDI PI ,l l 11726 2148 11727 2150 11729 2152 g HV I I b 1668B 4;rll QKB -iluri! ' ll -ilarll N U / LIT N O N O

=

1606 HV HV HV 1160 1160-11600 18' , TO TGVER TO BASIN N Ah L /~\\ / \\ / \\ 2-1202-P4-001 2-1202-P4-005 2-1202-P4-003 TRAIN 'A' NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-001 COOLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER LOVER i ,c c, ust.m. -i ma -s m-s 77 me ass vi unea m s-a-se as ets ursarts in arv e. y enesm32-t 77C Southern Company Services. Inc.roR Southern Nuclear Operating Company

==* "

*

8"c V0GTLE ELECTRIC GENERATING PLANT '"" " " ' v5 UNIT 2 PUMP INSERVICE TESTING LOOP FOR ",,an. $."d i., .t NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-001 N/A N/A ISI-D-250 10F 1 2

O O O NOTE: THIS IA A SIMPLIFIED DIAGRAM CV MC)<]l l'/pCID ADDITION USED TO DEPICT A TEST CIRCUIT. 9447 REFER TO THE P8,ID FOR DETAILS. (049): @F (077) BLIND FLANGE g TO Hl lM TE FC BLOVDOVN g g - 1643 1 ISPERSANT ADDITION 7' (168) (079) (078) S 3* (050) y y y [ p h h h l OMCB QMCB QMCB I6' 3 18' H 1603A 1609A 1635 j 18' W I g g l 11763 b l 11764 l 11765 1 u g = p; -=p 1669 g g NSCVS g ~~" ~ ~ " n y, 24. COMPONENTS PDI PI PDI PI PDI PI .l 11730 2149 11731 2151 11733 2153 k b 1669B -Od: OntB -91l -- vl! ' ll N O FLIT N O N O I1607 ) HV HV HV j 11612 11613 18' 11607 , TD TOVER TO BASIN M.AMML GMM /~\\ /~\\ /\\ TRAIN *B* 2-1202-P4-002 2-1202-P4-006 2-1202-P4-004 NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-002 COOLING VATER PUMP CDOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER TOVER =, ,r c,r. unwere. n iu -m e -2 .m. m.s mismas vi risw. r= est 1 .-26-gp sits eL 3 LF3nft 10 KV 19 (F 2W.9H3H JK r e-e -= ma'

=== ia aca"3 Southern Company Services. Inc.FOR Southern Nuclear Operoling Company i VOGTLE ELECTRIC GENERATING PLANT K58"' saawa =c "N" vs UNIT 2 PUMP INSERVICE TESTING LOOP FOR ",imma "E C our av. NUCLEAR SERVICE COOLING VATER l PUMP 2-1202-P4-002 N/A N/A ISI-D-251 171 2 i

O O O NOTD THIS IA A SIMPLIFIED DIAGRAM CV MD<]l lMpCID ADDITION USED TO DEPICT A TEST CIRCUIT. 9446 REFER TO THE P8.ID FOR DETAILS. O (040) (D743 BLIND FLANGE @ 2* ;g; g TO

g TE FC BLOVDOVN

- 1642 g1 y g nISPERSANT ADDITION (156) (076) QZ5) 3' L018.) U y y 24* 24* j[ j[ j 18 QMCB QMCB QMCB 16* 1602A 1608A 1634 18' 18' g j 11761 l !!762 l 11760 l 1 1r Ig 1668 NSCVS ~~" O 24 COMPONENTS ,l PDI PI PDI PI PDI PI { i 11726 214 8 11727 2150 11729 2152 g b 1668B g

gg:

-igg: -ligg: ' !l '1606 I HV HV ( j 116)0 HV 1160 = 11600 18* ,TO TOVER TO BASIN N_AhAh&NA L /~\\ / \\ / \\ 2-1202-P4-001 2-1202-P4-005 2-1202-P4-003 TRAIN *A* NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-001 COOLING VATER PUMP CDDLING VATER PUMP CDOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER TOVER =v ,c em ust.ieram i e ar 3 m sio.uins w.- er.: vs issure r, en n s t 1-PSM Wss WL S LPD.TED TD KV as IF SI400t23-1 JK ~ Southern Company Services, Inc.FOR Southern Ptuelear Operating Company V0GTLE ELECTRIC GENERATING PLANT K5= * " 'aava '=c UNIT 2 "t' mu' vs 5."$ C" m, I ' ~ PUMP INSERVICE TESTING LOOP FOR ua ,cy. NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-003 N/A N/A ISI-D-252 10F 1 2

O O O L NOTD THIS IA A SIMPLIFIED DIAGRAM CV i / 1*lNr li/pCID ADDITION i USED TO DEPICT A TEST CIRCUIT. 9447 i REFER TO THE P&ID FOR DETAILS. (049F (677) BLIND FLANGE D TO FlNl lig TE FC BLDVDOVN g - 1643 I f X ylSPERSANT ADDITION s i >{ Q6_8) (079) (6T8) 8 3' (050) ]fy 1f 24' 24' g g j OMCB QMCB l6' [ OMCB 3 H 18 1603A 1609A 1635 18" 18' g g j 11765 [ l 11763 l.j 11764 l m o V 1669 NSCVS a [ ~~* v 24 COMPONENTS n M" ~~ " PDI PI PDI PI PDI PI d 11730 214 9 11731 2151 11733 2153 g g b 1669B -il>rll ' ll OtiCB -H>rll ' ll --{>rll NO [ LIT NO N O I1607I HV HV HV (j 11612 11613 =: 11607 18' l . TO TOVER TO BASIN MJM A-GMM /~\\ /~\\ /~\\ 2-1202-P4-002 2-1202-P4-006 2-1202-P4-004 TRAIN *B' NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-002 COOLING VATER PUMP CDOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARD VATER TOVER =v.

== s, o, usawin. meu me n.u nm. 6 -s suomrs

  • w ass vi issues rar m n

i i-a-se ses at e emn in arv i, or emum a Southern Company Services, Inc.FOR Southern Nuclear Operating Company [ VDGTLE ELECTRIC GENERATING PLANT ' " * * "

== '"e ""' v5 UNIT 2 C" u PUMP INSERVICE TESTING LOOP FOR muta .y. NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-004 N/A N/A ISI-D-253 1 [F 1 2 f

O O O NOTE: THIS IA A SIMPLIFIED DIAGRAM CV 4M[><]' g"MCID ADDITION USED TD DEPICT A TEST CIRCUIT. 9446 REFER TO THE PLID FOR DETAILS. (047} D TO 2' ;g;

,g TE h

1642 FC BLOVDOVN I '/ X '/ nISPEP.SANT ADDITION (156 ) (UT67 (075) >S 3' (048) y Jf1[ O 24' g [ g 24' 18' S 4 QMCB OMCB [6' QMCB 1602A 1608A 1634 18' W 3 g l 11760 l 11761 l j 11762 1 L la v g 668 NSCVS C 24 COMPONENTS t PDI PI PDI PI PDI PI il 11726 2148 11727 2150 11729 2152 b g y 1668 -1XC ' ll OMEB Hl>r" ' ll ---G>r" NO [L1T NO NO

h 11606} HV HV HV (f 1160 1160

=- 11600 18 ,TO TOVER , TO BASIN MJMMAA-G /\\ /\\ /\\ 2-1202-P4-001 2-1202-P4-005 2-1202-P4-003 TRAIN 'A' NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-001 CDDLING VATER PUMP COOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER TOVER av mrs = ci., u se-rum. l.mu

== -u m. =u x rs

  • s-..

ms .a nu. = n. n i -n-a. .ss =e sans m av a or rumn-i a

  • ~

" ~ ' " " ~ " ~ Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT "5='

== "c UNIT 2

=== wt PUMP INSERVICE TESTING LOOP FOR " [v,$ $."." ~ m NUCLEAR SERVICE CDOLING VATER PUMP 2-1202-P4-005 N/A N/A ISI-D-254 10F ! 2

O O O NOTE: THIS IA A SIMPLIFIED DIAGRAM M USED TO DEPICT A TEST CIRCUIT. 9447 MC)<:}----{MpCID ADDITION REFER TO THE P8.ID FOR DETAILS. (049) Q67_) 2' ;g;

gp_4[ BLIND FLANGE (041) (077)

D TO TE FC BLOVDOVN g - 1643 1 ISPERSANT ADDITION >S (168) (079) (078) 3' (050) y Q y a" ET' 24' h j j[ OMCB QMCB QMCB I6' 18' H 3 1603A 1609A 1635 18' W 1 g g l 11763 l 11764 l 11765 4 le Ip 1m y 1669 NSCVS ~ ~ " V 24. COMPONENTS 7" PDI PI PDI PI PDI PI ,l l i 2149 11731 2151 11733 2153 n @ 11730 b h 1669B -{;rll ' ll OtiCB ---g;rll ' ll --l;rll ' ll NO (LIT N O N O 1: l HV HV l1607 ) 11612 HV () 11613 = 11607 Ig- , TO TGVER TO BASIN MAMMA. G / \\ / \\ /\\ l 2-1202-P4-002 2-1202-P4-006 2-1202-P4-004 TRAIN *B' [ NUCLEAR SERVICE NUCLEAR SERVICE NUCLEAR SERVICE 2-1202-V4-002 COOLING VATER PUMP CDOLING VATER PUMP COOLING VATER PUMP NUCLEAR SERVICE COOLING (SPARE) VATER TOVER t uv. satt se ces scscorruse meu was me.2 maa mes sciemus me

== vs issa. ra.,s, n I FES M 88: WL 5 LF9htE TB KV 19 IF russes33-2 JJc t Southern Company Services, Inc.FOR Southern Nuclear Operating Company f ~ ~ "~"" V0GTLE ELECTRIC GENERATING PLANT" = = ' vs i "s= ' "

    • =

c UNIT 2 PUMP INSERVICE TESTING LOOP FOR ",muis $$C" m, f .y. NUCLEAR SERVICE COOLING VATER PUMP 2-1202-P4-006 N/A N/A ISI-D-255 1 [F 1 2 + 1

NOTE: THIS IS A SIMPLIFIED ' DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TO THE PLID FOR DETAILS HV FI PI 1670 2156 8895 i O l lll ? ag 8'X6' LD 4 0MCB M FI HV PI 2166 2157 1671 167A i 2154 LD 8'X6' 3 [- 6' Ml! l l C [ I PI PDI ~ 6' 2155 4 QMCB 11728 PI 1606 8894 OMCB i I lp i PD1 1607 d! D 1173 WMAhA.AA.A> h vhJh N / \\ / \\ 3r 2-1202-P4-007 TRAIN 'A' 2-1202-P4-008 TRAIN 'B' TRANSFER PUMP 2-1202-V4-001 TRANSFER PUMP 2-1202-V4-002 NUCLEAR SERVICE COOLING NUCLEAR SERVICE C00 LING VATER TOVER VATER TOVER =v. mm o-,

==.-r .-2 m. e ++= mm vs namn rm m - n i i-=-es

=

== warte ve av. m n.nem av. i, n_._3a a Ate-M vtV M 333 Pg-ge,. & 7 Aac w+w av.S mm -,7 EELETT9 serv esmeras [ gw.s Southern Company Services, Inc.rog Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT =$*<* = =c " E *,'. " ' rv UNIT 2 ~ '** PUMP INSERVICE INSPECTION LOOP =v. FOR TRANSFER PUMP 2-1202-P4-007 N/A N/A ISI-D-256 1 IF 1 3

( J v s NOTE: THIS IS A SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TO THE P&ID FOR DETAILS HV FI pg 1670 2156 8895 e. I i i g 't k ^ 8'X6' 'LO' 4 0MCB 4 0MCB PI 166A 2157 1671 167A 2154 LO 8'X6' ll! l l 0 8' PI PDI 6* 2155 QMCB 11728 PI 1606 8894 OMCB lH hDI 1607 N E 1173 WMA N vm.) N / \\ / N + 2-1202-P4-007 TRAIN 'A' 2-1202-P4-008 TRAIN *B' TRANSFER PUMP 2-1202-V4-001 TRANSFER PUMP 2-1202-V4-002 NUCLEAR SERVICE CDOLING NUCLEAR SERVICE CDOLING VATER TOVER VATER TOVER ev.

== = o.,

=

-s =+ som vs unes run ni n i N-88 "BS E3 LP=YE3 70 =V. EB EE.MB33-9. IEv. 39 tu4pge3M J.c e 4-w ww = => = :.== arw ev --- a a ie-e-w sv. aats . wn..c ,2 ages Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT = 5= * " n=wa

  • =c PUMP INSERVICE INS ECTION LOOP re

=v. FOR TRANSFER PUMP 2-1202-P4-008 N/A N/A ISI-D-257 1 [F 1 3

CCW Pumps (2-1203-P4-001, 002, 003, 004, 005, & 006) L System Function ~ Remove waste heat from the spent fuel pool heat exchangers, RHR heat exchangers and the RHR pump seal coolers during plant operation, plant cooldown and during a s postulated post-accident condition. This heat energy is then transferred by the component cooling water heat exchangers to the NSCWS. The CCWS functions as an 4 intermediate system between a radioactive fluid system and the non-radioactive NSCWS, which operates at a higher system pressure This arrangement greatly reduces the probability of radioactive fluid leakage to the enviroment by means of the NSCWS. Quantity 6 4 1 Type Horizontal, centrifugal, single-stage, split volute with mechanical seals Manufacturer /Model Ingersoll-Rand /10x18 SE Rated Capacity 5000 gpm (each) Rated Total Dynamic Head 160 feet O Driver Type Electric Motor, Westinghouse, LAC-LLD, 5008-S Horsepower 300 Speed 1761 rpm-Power Supply 4160V,60 Hz,3 phase Code Class 3 Project Class 313 Outline Drawing 2X4AF01-109 & 2X4AF01-110 Instruction Book 2X4AF01-137 Physical Location Aux Bldg, Level A, Rooms R-A96 & R-A98 P&ID 2X4DB136 Surveillance Procedure 14803-2 Pump Test Loop Diagrams ISI-D-258 through ISI-D-263 Test Parameter Sheets Page 16-3 through 16-8 16 - 1 Rev.O

O O O i Test Parameter Table - Pump 2-1203-P4-001 (Figure ISI-D-258) Instrumentation Utilized Ref. Acceptable Alert Action l .l Parameter Iest Frea. 1.D. NoJ3) Range Rea. Acc. Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver L Inlet Pressure Qtr PI-1878 0-60 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1858 0-200 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er >l.10APr NA (AP) Flowrate Qtr FI-I1794 0-10000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA .1 5 % Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Nctes:

1. DifTerential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

I

4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

16-2 Rev.0 f i

O O O 1 Test Parameter Table - Pump 2-1203-P4-002 (Figure ISI-D-259) Instrumentation Utilized Ref. Acceptable Alert Action Oarameter Int Freq. ' I.D. No.(3) Range Rea. Acc. Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Coastant speed driver inlet 6 Pressure Qtr PI-1881 0-60 12% NA NA NA NA NA i (Pi) psig l Outlet Pressure Qtr PI-1859 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr FI-l1795 0-10000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm I Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s t Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

[ 16 -3 Rev.0 ) m m - m + w--

r r (' l J Test Parameter Table - Pump 2-1203-P4-003 (Figure ISI-D-260) Instrumentation Utilized Ref. Acceptable Alert Action Earamtitt Test Freq. I.D. NoJ3) Range Rea. Acc. Value Range Range Range Comments 1 Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-1879 0-60 12% NA NA NA NA-NA (Pi) psig Outlet Pressure Qtr PI-1860 0-200 12% NA NA NA NA NA e (Po) psig 1 Differ. Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr FI-I1796 0-10000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm I Vib. Amp. Qtr (2) NA 15% Vr 5 2.5Vr >2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s 1 I N:tes:

l. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial l

direction on each accessible thrust bearing housing. L k 16-4 Rev.0 i . m . s

N Test ParameterTable - Pump 2-1203-P4-004 (Figure ISI-D-261) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. 1.D. No.f3) Range Beg Act Yalac Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-1882 0-60 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1861 0-200 12% NA NA NA NA NA (Po) psig Differ. l Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er >1.10aPr NA (AP) Flowrate Qtr F1-11797 0-10000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr 5 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

r 16 - 5 Rev.0 L .m m

O /~} U .%) i Test Parameter Table - Pump 2-1203-P4-005 (Figure ISI-D-262) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea. I.D. No (3) Range Req. Acc. Yalue Range Bange Range Comments Speed [ (N) NA NA NA NA NA NA NA NA Constant speed driver [ Inlet Pressure Qtr PI-1880 0-60 2% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1862 0-200 12% NA NA NA NA NA e (Po) psig DitTer. i Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA <.90 er >l.10APr NA (AP) l Flowrate Qtr FI-l 1798 0-10000 i2% Qr NA NA NA Flowrate is set at reference value i (Q) gpm j L Vib. [ Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA L (V)(4) or >.325 in/s >.70 in/s Nites:

1. Differential pressure is calculated as, AP = Po - Pi r
2. Pcatable vibration instruments are utilized.

l

3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial L

direction on each accessible thmst bearing housing. i f 16 - 6 Rev.0 l i

Test Parameter Table - Pump 2-1203-P4-006 (Figure ISI-D-263) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea. I.D. No.f3) Range Rea. Ace. Value Range Range Range C.cmments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet l Pressure Qtr PI-1883 0-60 2% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-1863 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er >l.10APr NA l (AP) Flowrate Qtr FI-l 1799 0-10000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA 15% Vr-s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s 1 N:tes: i

1. Differential pressure is caseilated as, AP = Po - Pi

[

2. Portable vibration instr:nnents are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

{ t i ) 16-7 Rev.0 i i .. ~ ~.

.. ~ . ~.. -. - - O O O i S QMCB HV PI 1852A gy NOTE: THIS IS A SIMPLIFIED PI F1 1858 11803 DIAGRAM USED TO DEPICT 11800 1878 II79 A TEST CIRCUIT. REFER 14*X10* LO TO THE P8.ID FOR DETAILS. LO / 'N' 16' 030$ -1203-P4- 01 16'XI XI CMPNT. CLG. l4, p20'X16' VATER PUMP HS PI HV pg HV PI 954 1960 11804 11801 1879 1179 14*X10' LO LG c lNl l l 16' 16*X1 2-1203-P4-003 O XI CMPNT. CLG. VATER PUMP 18* 14' HS PI HV 1179 HV PI 1862 11805 856 0 20'X16' 1180 1880 IO' If CCVS I,_0 gl lN' f' l 8*X14' COMPONENTS 16" 16'X14" 2-1203-P4-005 (034) ~ ~ CMPNT. CLG. i ATER PUMP 2'X18, 20' (SPARE) 18' 1 li ~ b ~I' LO Hv 4" COMPONENT CLG. VATER 11807 = p' HEAT EXCHANGER i y COMPONENT CLG. VATERNLO 2-1203-E4-001 SURGE TANK ) HV l_ 2-1203-T4-001 j 11806 T W V 22'X20' 1866 -- TRAIN *A' [ 9 N Mit WS iJ.T.E3 f1R PIT I l s e-es-es as ets wup to av. se er en sam _JC ~ """~ Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT==* " c UNIT 2 ".mLE " "'" v5 empt GBff8'EB E 3DEZI PUMP INSERVICE TESTING LOOP FOR m n .v. COMPONENT COOLING VATER PUMP 2-1203-P4 -001 N/A N/A ISI-D-258 i [F 1 2

O O O / TIS'\\QMCB PI HV NOTE: THIS IS A SIMPLIFIED HV PI 1853A FI 1859 11811 DIAGRAM USED TO DEPICT i 11808 1881 II79 A TEST CIRCUIT. REFER 14*X10" Lo, TO THE P8.ID FOR DETAILS a, 16' 16*X1 2-1203-P4-002 XI CMPNT. CLG. g4 1120'X16' 02 VATER PUMP QMC PI HV FI 855 1861 11812 118 9 1882 33797 14*X10' LO VD c lN' 16' 16*XI 2-1203-P4-004 E i XI CMPNT. CLG. VATER PUMP 14' t QMC H, PI HV 1179 HV PI 857 1863 11813 I ' U 20'X16* 11810 1883 18' 14 X10' LO CCVS l 18'X14' COMPONENTS LD 16' 16*X1 2-1203-P4 06 O C CMPNT. CLG. VATER PUMP 20' XI (SPARE) 18' i! Ii 6 _m._ i + h ) T LO HV 4 COMPONENT CLG. VATER 11815 i i e HEAT EXCHANGER I y COMPONENT CLG, VATER LD -1203M-002 SURGE TANK HV l-2-1203-T4-002 11814 T E0 f ~ 22'X20' 1867 ~ ~~ TRAIN 'B' e 'a iza vs usurs rar est FI i -es* ms ate wearen To av. se y as4asem JJC "~"~ Southern Company So vices, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT "[58"

  • =' =

UNIT 2 "=* w$ PUMP INSERVICE TESTING LOOP FOR "E U' r, u. COMPDNENT CDOLING VATER PUMP 2-1203-P4-002 N/A N/A ISI-D-259 I [F 1 2

O O O M QMCB pl HV PI 1852A HV NOTD THIS IS A SIMPLIFIED FI 1858 11803 DIAGRAM USED TD DEPICT 11800 1878 1I79 A TEST CIRCUIT. REFER l4'Xl0' 0 TO THE P8.ID FOR DETAILS. 0 j N l I,' 16' 16*XI 2-1203-P4-001 XI CMPNT. CLG. g4 Il 20*X16' 502 VATER PUMP OHC PI HV 854 1860 11804 11801 1879 jg79 14'X10* LD LO c IN:

1 ll I,'

u 16' 16*XI 2-1203-P4-003 O i _ _ XI CMPNT. CLG. 5026 VATER PUMP 14' QMC h PI HV 11 9 ~' O HV PI 856 1862 11805 IB.I U 20*X16' 1180 1880 = CCVS H lNl [l l 18'X14' COMPONENTS LO 16' (034) 16'XI 2-1203-P4 5 C

  • CMPNT. CLG.

ATER PUMP 20' (SPARE) 22'X18* 18' iI Ii ~ h _a_ n T LD 4" HV COMPONENT CLG. VATER 11807 HEAT EXCHANGER i i y COMPONENT CLG. VATER 0 2-1203-E4-001 SURGE TANK HV 3-2-1203-T4-001 11806 T W V 22'X'20' 1866 ~- TRAIN 'A' _s 9 FM EiB VE ESED f1R PST -I a e as als irsarts to av. r emessim . JC "~"~ Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT "S**

=

UNIT 2

==* vi DUMP INSERVICE TESTING LOOP FOR ~ECC' ,,o, ~ COMPONENT COOLING VATER PUMP 2-1203-P4-003 N/A N/A ISI-D-260 1 (1r 1 2

O O O M OMCB pr gy NOTE: THIS IS A SIMPLIFIED HV PI 1853 FI DIAGRAM USED TO DEPICT 1859 11811 11808 1881 1179 A TEST CIRCUIT. REFER 14*X10* LD TO THE PLID FDR DETAILS. LD l c lN' l l, D-i 14' i 16, 16*X14* 2-1203-P4-002 g4, XI CMPNT. CLG. 1120'X16' 5025 VATER PUMP "h PI HV FI 855 1861 11812 11809 1882 11797 I 14*X10' LO LO c lN l l 16*X1 2-1203-P4-004 O 16' i XI CMPNT. CLG. VATER PUMP QMC PI HV 1179 HV PI 1863 11813 857 U 20'X16' 11810 1883 gg, CCVS LO H IN' fi l-18'X14' COMPONENTS N 16' 16*X1 2-1203-P4 6 -i = CMPNT. CLG. ATER PUMP 22'X18' 20' (SPARD 18'ij ge H T LD HV 4' COMPONENT CLG. VATER 11815 sp HEAT EXCHANGER i y COMPONENT CLG. VATER LD SURGE TANK HV l-2-1203-T4-002 11814 T U EO f 22'X20' L 1867 -- TRAIN *B' ) nm ei i e-es-as et ats tranrts a uv. se r exassin JJC " " " " ~ Southern Company Services. Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT **e = c UNIT 2 " " vs PUMP INSERVICE TESTING LOOP FOR "EU' x, [ mus COMPONENT CDOLING VATER PUMP 2-1203-P4-004 N/A N/A ISI-D-261 1 [F 1 2 t

( lh Y Y PI HV PI Hy NOTE: THIS IS A SIMPLIFIED } 1858 11803 MGM M TD DMCT 11800 1878 gg79 A TEST CIRCUIT. REFER 14'X10 hO TO THE PLID FOR DETAILS. LO 'qi e e N 14' ~ 6* 16*X14' 2-1203-P4-001 O XI CMPNT. CLG. I4' H 20*X16' 5024' VATER PUMP PI HV ,1860 11804 11801 1879 1179 14*X10* LO 'O c lN: Ii M 14* 16'X14' 2-1203-P4-003 O 16' XI CMPNT. CLG. 5026 VATER PUMP 14 DMC FI HS P1 HV 1179 HV PI 1862 11805 If yg,1I N20*X16* 1180 1880 r CCVS 14*X10' LD l 18'X14* COMPONENTS fu, y.4l

q; e

16, '~__ 16'X14* 2-1203-P4-005 E CMPNT.CLG. ATER PUFP 22*X18' 20' (SPARE) 18'.iI la i _i_ a T LO 4' HV COMPGNENT CLG. VATER 11807 HEAT EXCHANGER j f COMPONENT CLG. VATER LD 2-1203-E4-001 SURGE TANK HV _1_ 2-1203-T4-001 11806 T 1f 22*X20' = TE LD 1866 PES e am e, a== m-_._ m. ms 9 77 % EE vt 13SE3 FIR PST fI i ,-as e et ets waarts is arv. se y emessem .1C ~~"~ Southern Company Services. Inc.FOR Southern Nuclear OperoHng Company VDGTLE ELECTRIC GENERATING PLANT - " = =c UNIT 2 g, y_, PUMP INSERVICE TESTING LOOP FDR a. o COMPONENT COOLING VATER PUMP 2-1203-P4-005 N/A N/A ISI-D-262 I [F 1 2

O O O / TIS'\\0MCB PI HV NOTE: THIS IS A SIMPLIFIED HV PI 853 FI DIAGRAM USED TO DEPICT 1859 11811 11808 1881 1179 A TEST CIRCUlT. REFER 14*X10" LO TO THE PLID FOR dei.c,ILS. LO c lN 16' O 16'X1 2-1203-P4-002 g4, XI CMPNT. CLG. 1120'X16" 5025 VATER PUMP 0" h PI Hy HV PI FI 1861 11812 gg797 gg 9 18g2 855y 14*X10' LO LO .N' ~ 16*XI 2-1203-P4-004 E 16' XI CMPNT CLG. VATER PUMP H P1 HV 1179 L, HV PI 1863 11813 gg. I I 857 O 20*X16' 11810 1883 CCVS 14*X10' LO l 18'X14' COMPONENTS O K' 16* 16*X1 2-1203-P4 06 O C O CMPNT. CLG. ATER PUMP 22*X 8' 20' (SPARE) 18',ig gi h T LD HV 4' COMPONENT CLG. VATER 11815 ig HEAT EXCHANGER i y COMPONENT CLG. VATER LO ~ ~ ~ SURGE TANK HV I-2-1203-T4-002 11814 T W10 22'X'20' L 1867 -- TRAIN 'B' e ,+= su vs nuns nsi ne ti n e-m-es ca. sta tenarts to av. a. r asesoim JJC "~"~ Southern Company Services, Inc.FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT==' " UNIT 2

=== vs PUMP INSERVICE TESTING LDDP FDR ua C h"' COMPONENT CDOLING VATER PUMP 2-1203-P4-006 N/A N/A ISI-D-263 1 [F 1 2

4 SIPumps (2-1204-P6-003, & 004) ] System Function The SI system provides emergency core cooling and serves 4 no other purpose. 'l l The primary function of the ECCS is to remove the stored and fission product decay heat from the reactor core j following an accident in order to prevent fuel rod damage. i Quantity 2 Type Horizontal, centrifugal,11-stage s Manufacturer /Model Paci6c Model 3-ht., JHF 4 Rated Capacity 440 gpm Rated Head 2630 ft. Driver Type Electric Motor, Westinghouse, Frame 5809 H Horsepower 450 Speed 3600 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2 Project Class 212 Outline Drawing 2X6AG02-10,13 & 15 Instruction Book 2X6AG02-016 Physical Location Aux Bldg, Level B, Rooms R-B117 & R-B119 P&ID 2X4DB121 Surveillance Procedure 14804-2 Pump Test Loop Diagrams ISI-D-264 & ISI-D-265 Test Parameter Sheets Page 17-2 & 17-3 D 17 - 1 Rev.O

o O i Test ParameterTable - Pump 2-1204-P6-003 (Figure ISI-D-264) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. No.f3) Range Rea. Acc. Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver s Inlet Pressure Qtr PI-0977 0-100 i2% NA NA NA NA NA i. (Pi) psig Outlet Pressure Qtr Test NA 12% NA NA NA NA NA i i (Po) Gage Differ. Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA <.90 or >l.10APr NA l (AP) i t Flowrate Qtr FI-0968 0-100 i2% Qr NA NA NA Flowrate is set at reference value p (Q) gpm ~ Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA l (V)(4) or >.325 in/s >.70 in/s i. Notes: ^

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

i 17-2 Rev.O

~. _._..._ ____ _. _ _.m Test ParameterTable _- Pump 2-1204-P4-004 ' (Figure ISI-D-265) Instruments. lion Utilized Ref. Acceptable Alert Action Earameter Test Frea. 1.D. No.(3) Range Rea. Ace. Value Range Range Rance Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet ' Pressure Qtr PI-0978 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr Test NA 12% NA NA NA NA NA i (Po) Gage Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr FI-0968 0-100 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

17 - 3 Rev.0

/G Og [N U V U l NOTE: THIS IS A SIMPLIFIED VPS REAC DIAGRAM USED TO DEPICT M" 2, HV 3'X3/4" CVCS BA BLENDER C CDDL DRAIN ? [ 2, A TEST CIRCUlT. REFER O CSS TEST LINE 8964 ~ k' 8964 jf 00 TANK PUMP g If @ I fIf (0.02) TO THE P&ID FOR DETAILS. SIS BORON INJECTIONj 3/4" "FC' ~ REFUELING VATER O TEST LINE HV SFPCS PCP STORAGE TANK HS MCB 8813 PURIF 3' 09 8 ~' 8888 PUMP (003) 807 1 0 813 M 3'X2' HV HV 807 i (FC H

t. --

QMCB 3'X11/2 8814 HV OMCB 8888 r M MCB 3/4-8814 CVCS CHARGING 802 k L 3/4' LOCAL 07B H N C 1 1/2* 6, b QM B 4' 093 9 HV MCB Hv HS A X11/2' M g0 B QHCB 999 g23 pg 24' H (100 ) (098) 0977 UM OI 4

  • X3, D

b^ (207 LD 3'X11/2' 2-1204-P6-003 6-SIS COLD LEG LOOP _4' / PI T H PUMP XI TI s SAFETY INJECTION H L HV 8806 HV 8920 M TRAIN *A. LO 135 QMCB 821B MCB gy 8'X6' WO M QMCB 8806 821B M HV -QMCB HV PI 923 Luh136) 802 101 ) (099) h OW8 1 1/2' 4, 4'X3, H 8 r LO 2-1204-P6-004 i 6, (163) s L SAFETY INJECTION CMCB 4' TRA N *B' 8' " ' R R HEAT EXCH NGER-e. .m e, o., -.4 -u -.2 m. -s

=

we.-

== vs unrsrm m tI a e-es-es ca- .ts woms a uv. es or exesem JJC Southern Company Services, Inc.rOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT==* " "c UNIT e <,,,,, y,,,, PUMP INSERVICE TESTING LOOP ,.au. FOR SAFETY INJECTION PUMP 2-1204-P6-003 N/A N/A ISI-D-264 iT1 2

/ p Q,) ] NOTE: THIS IS A SIMPLIFIED VPS REAC DIAGRAM USED TO DEPICT M MCB E, ^ 2, ' ' HV 3'X3/4" CVCS BA BLENDER COOL DRAIN A TEST CIRCUIT. REFER 8964 CSS TEST LINE 7;2 k'8964 ~ Q03) TANK PUMP 0 TO THE P8.ID FOR DETAILS. y gy y y SIS BORON INJECTIONj 3/4' 'pC' REFUELING VATER N jl QM B PCP TEST LINE HV SFPCS STORAGE TANK M MCB 8813 PURIF 3' HS3 TS 2-204 -T4-001 09 8 813 M 3'X2' HV HV (FC 807 H t--- QMCB 3'X11/2 8814 HV QMCB r M M 802 k 3/4' 8814 CVCS CHARGING k 3/4 LOCAL WM 1 1/2* 6 07B H NMP ^" QMCB 4' 093) 3 H HV M MCB 821A 3' ,_M3*X11/2, HV gO B QMCB / pj 923 4, 0977 821A M 4*X, LO 3"X11/2" 2-1204-P6-003 0 ) 6' SIS COLD 4 SAFETY INJECTION h L HV LEG LOOP / PI \\ PUMP XI TI 1 8806 H 8920 M TRAIN *A. LO 135) QMCB QMCB - HV 8'X6* 090 M 8806 MCB 821B M (099) PI 923 QMCB HV LD 802 0978 1 1/2* 4, 4*X3, HV HS P LO 2-1204-P6-004 0 D 802 Ms 6, (163) L SAFETY ECTION QMCB 4* "'RhRHEATEXHNGER D yp g ,B' 8" e.

== = o.s ,,.a ., = .m. e =: vi naza rm en t1 i

    • as ca

== temen in uv. ee y ensam JJC '~*~ Southern Company Services. Inc.FOR Southern Nuclear Operoling Company V0GTLE ELECTRI EgERATING PLANT =_5=' _= = ~ PUMP INSERVICE TESTING LUDP ua u a FOR SAFETY INJECTION PUMP 2-1204-P6-004 N/A N/A ISI-D-265 1 [F 1 2

l i RHR Pumps j (2-1205-P6-001, & 002) i O' System Function ~ The primary function is to remove heat energy from the reactor core and reactor coolant system during plant cooldown and refueling operadons. As a secondary function, RHR is used to transfer refueling water between the refueling water storage tank and the refualing cavity at the begin. ing and end of refueling operations. i Portions of the RHR system also serve as part of the ECCS during the injection and recirculation phases of a LOCA. Quantity 2 Type Vertical, centrifugal, single stage Manufacturer /Model Ingersoll-Dresser,8X20WDF Rated Capacity 3000 gpm Rated Head 375 ft. Driver I g Type Westinghouse LLD squirrel-cage induction motor i Horsepower 400 ( Speed 1780 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2 Project Class 212 Outline Drawing AX6AF02-20007 Instruction Book AX6AF02-20030 PhysicalLocation Aux Bldg, Level D, Rooms R-D21 & R-D22 P&ID 2X4DB122 Surveillance Procedure 14805-2 & 14812-2 ) Pump Test Loop Diagrams ISI-D-266 & ISI-D-267 Test Parameter Sheets Page 18-2 & 18-3 O 18 - 1 Rev.0 1

s J a Test Parameter Table - Pump 2-1205-P6-001 (Figure ISI-D-266) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. No.(31 Range Req. Acc. Value Range Range Range comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-8884 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8886 0-400 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr F1-0618A 0-5000 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or>.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

18 -2 Rev.0

O O O Test Parameter Table - Pump 2-1205-P6-002 (Figure ISI-D-216) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freg, I.D. No.0) Range Reedcc. Value Bange Range Range Comments i Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-8885 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8887 0-400 12% NA NA NA NA NA i (Po) psig DitTer. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr FI-0619A 0-5000 12% Qr NA NA NA Flowrate is set at reference value i (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instnr

' tion other than that listed, which meets the requirements of the Oh! Code, may be utilized for measuring test parameters.

4. Measurements are taken in a,

.e pproximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible th.a bearing housmg. i i 18 - 3 Rev.0 j

f h Test Parameter Table - Pump 2-1205-P6-002 { (Figure ISI-D-216) Instrunnentation Utilized Ref. Acceptable Alert Acties Parasmeter Test Free. LD. No.f3) Ranee Ree. Acc. Value Ramme Ranee Range Connasents Speed (N) NA NA NA NA NA NA NA NA Constant speed dnver Inlet Pressure Qtr PI-8885 0-100 12% NA NA NA NA NA (Pi) psig i f Outlet Pressure Qtr PI-8887 0-400 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er >l.10APr NA (AP) Flowrate Qtr F1-0619A 0-5000 12% Qr NA NA NA Flowrateis set at reference value ( (Q) gpm t Vib. Amp. Qtr (2) NA 15% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA [ (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differental pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of GPC, instrumentation other than that listed, which meets the reqmrements of the OM Code, may be utilized for measuring test parameters.

l

4. Measurements are taken in a plane approximately r.r..dkwlar tc the rotating shan in two orthogonal directions on each accessible

. Wing housing and in the axial e direction on each accesnNe thrust bearing housing. 18 -3 Rev.O

Ag / h NOTD THIS IS A SIMPLIFIED hN" FROM CONTAINMENT DIAGRAM USED TO DEPICT 618A 0618 FV = EMERGENCY SUMP A TEST CIRCUIT. REFER 0610 2-1205-E6-001 MCB MCB TO THE P8.ID FOR DETAILS. 00 pg pr QMCB 0618 HV 614/ 8886 HS HV REFUELING VATER HV FT 606 0606 T 0620 881I M 0618 (ogg 0612 PI STORAGE TANK 809 2-1204-T4-001 0601 P SIS 8' y y d li: ] v COLD LEG U LOOP 8* Jl FO '~ g-M *xe-For @D

14.,

l N XI TI PI HV 804 M l' 06 8 FV M' 70 A CVCS CHARGING - f 0618 CVCS LETDOVN 2-1205-P6-001 PUMP SUCTION r HEAT EXCHANGER RESIDUAL HEAT 1 HV rg HEADER REMOVAL PUMP J 812 N ,C 8 t g HV c' 8' ,L C, ,L C, RC 76 LO 1 M U RHTkO27) (226) 12' 24-I FV RCS FDT 0611 U HOT LEG ' " ' 12 X8' HV QMCB M PI QMCB 1 ' HIC LOOP 716 o 0615 8887 HV HV 607 M 0621 809 y z 0607 MCB 4*X8' (020 0613 y 0602 02 M ll ll -hG li; ( ] I* I SIS B g. 12* 12 -RCS HOT LEG COLD LEG T -- r, LOOP FT 2" 2-1205-E6-002 LOOP 4 ^ e-QMCB 0619 RHR HEAT EXCH k QMCB p; b HV 0619 ' 0619 (022) 5015 5017 8885 HV b FY D le 8811B 812 [g9 804 0619 CVCS LETDOVN 2-1205-P6-002 f l HEAT EXCHANGER RESIDUAL HEAT 1 F (002 ) HV SIS SAFETY _J REMOVAL PUMP J L M 812 INJECTION 0 FROM CONTAINMENT 0619 s. PUMP SUCTION FC EMERGENCY SUMP, MCB L-=-- FDT 3 12' MV. 94'E SY Dar g tKEERIPYED0 8PMt 3 APP 97 APf4.3 AP99 4 AP543 GEpulfRE 9 T*S-9 98iB v5 332UF9 FER Pf? I a -e+-se ca sts urwts to Mvir or enassize - JC

  • ~"-"

C't%,,,,'s,',7t Southern Company Services. Inc. FOR Southern Nuclear Operofing Company 3 in-a-= = = =vi. .c..o M5 UNIT 2 " * ' v5 PUMP INSERVICE TESTING LOOP ~,,,an [.~m$,7t ,,n, FOR RESIDUAL HEAT REMOVAL PUMP 2-1205-P6-001 N/A N/A ISI-D-266 10F 1 3

(% ~\\ 0 V (V V THIS IS A SIMPLIFIED nil"CM" FROM CONTAINMENT NOTE: DIAGRAM USED TO DEPICT I 618 0618 FV EMERGENCY SUMP A TEST CIRCUIT REFER 0610 2-1205-E6-001 MCB MCB TO THE P&ID FOR DETAILS. 00 pg pr QMCB 0618 HV 0614 8886 H HV REFUELING VATER HV FT 606 0606 TE 0620 8 811 STORAGE TANK 809 M 0618 \\ gg9 0612 0601 1 r g SIS 8" l4 d ) h 'i' '[ ll G y COLD LEG d ro U LOOP 8' 2' I 8 FDT N g4 06 804 't FY r' 8884 H (1223 g, CVCS CHARGING - 0618 CVCS LETDOVN 2-1205-P6-001 PUMP SUCTION Y r HEAT EXCHANGER RESIDUAL HEAT 9 r HV HEADER N C 8, p REMOVAL PUMP J L 812 M HV U / 8' j C, LC, RCbu F i " HV c 76 RHT 2 @ (h6) Y 12' U w 24' FV 12*X8, 0611 QMCB M PI QMCB HD LEG HV m 0615 8887 M LOOP 8716 7 HV HV TE 0621 p309 M r 0607 4*X84 (020 06 2 02 I 8* I M[ SIS 4 l ll G

i:

RCS HOT LEG 12-o y COLD LEU T-I i i LOOP 4 LOOP FT 2* 2-1205-E6-002 (010 ) ' i^ e-QMCB 0619 R[iR HEAT EXCH { OMCB p /flC'\\ 5015 8885 HV TI (12) HV 0619. FV gr 8811B 804 LOO 0619 CVCS LETDOVN 0619 f 2-1205-P6-002 HEAT EXCHANGER 1 F (002 ) HV ^ RESIDUAL HEAT WM 812 SIS SAFETY 2 j g g INJECTION H l> ll REMOVAL PUMP FRO 4 CONTAINMENT 619 8 g PUMP SUCTION F: EMERGENCY SUMP, j MCB W FDT 12' Ev. Mit 9T Csa ? MsCar,pe APre s aP992 APPR3 APPR 4 arpt3 Espets 9 9-S44 mis WT TEStK9 STR *TY I i

-es-es cc et.

trwrts to arvn or es. esser -JC ","",t"L"a',71 ~ Southern Company Services, Inc.FOR Southern Nuclear Operating Company ~ ~~" EgERATING PLANT _g'a y E=8 o VOGTLE ELECTRI PUMP INSERVICE TESTING LOOP ~,coua SAE .u r .tv FOR RESIDUAL HEAT REMOVAL PUMP 2-1205-P6-002 N/A N/A ISI-D-267 10F 1 3

CS Pumps (2-1206-P6 001, & 002) f'~ System Function Containment spray limits the peak pressure in the containment to less than design pressure following a LOCA or a main steam line break inside containment. Trisodium phosphate is mixed with recirculated spray water in the containment sump region for pH control and to enhance absorption of the airborne fission product iodine and to retain the iodine in the containment sump solution to limit calculated offsite doses to less than 10CFR100 limits. Quantity 2 Type Horizontal, centrifugal Manufacturer /Model Goulds Model 3415 Capacity 2600 gpm Total Dynamic Head 450 ft. Driver Type Westinghouse electric motor, Frame 5010S Horsepower 400 g Speed 1777 rpm Power Supply 4160V,60 Hz,3 phase Code Class 2 j Project Class 212 Outline Drawing 2X6AD02-10 Instruction Book 2X6AD02-18 Physical Location Aux Bldg, Level D, Rooms R-D04 & R-DOS P&ID 2X4DB131 Smveillance Procedure 14806-2 Pump Test Loop Diagrams ISI-D-268 & ISI-D-269 Test Parameter Sheets Page 19-2 & 19-3 19 - 1 Rev.0

o o D i Test Parameter Table - Pump 2-1206-P6-001 (Figure ISI-D-268) instrumentation Utilized Ref. Aeceptable Alert Action l Parameter Test Frea. I.D. No.(3) Range Rea. Acc. Value Range Range Range Comments r Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-0972 0-100 12% NA NA NA NA NA i (Pi) psig l ( Outlet i ( Pressure Qtr PI-0974 0-300 i2% NA NA NA NA NA (Po) psig i Differ. Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) r Flowrate Qtr F1-0929 0-400 12% Qr NA NA NA Flowrate is set at reference value j (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or - NA (V)(4) or >.325 in/s >.70 in/s { s Notes: ( l

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instmments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

I i 19 - 2 Rev.0 . ~ n

O O l Test Parameter Table - Pump 2-1206-P6-002 (Figure ISI-D-269) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. 1.D. No.(3) Range Req. Acc. Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-0973 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-0975 0-300 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - l.10APr NA <.90 er >l.10APr NA (AP) Flowrate Qtr F1-0929 0-400 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. l A m p. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA I (V)(4) or >.325 in/s >.70 in/s l t Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial i

direction on each accessible thrust bearing housing. 8 k 19-3 Rev.0 t i m

p ,/- N Q -] 0 NOTE: THIS IS A SIMPLIFIED ,L C, p, DIAGRAM USED TO DEPICT r, A TEST CIRCUIT. REFER M TO THE P8.ID FOR DETAILS. HV 003 d 9003 QMCB QMCB QMCB ("> 9001 M FROM CONTAINMENT HV TI PI 1094 1 9001A 0938 0974 PI 12' EMERGENCY SUMP FI 929 QM 0972 12,X10, TD Cny T^.!NMENT - yq I 12*X10* U 12' SPRAY 8, F-c n o-- a e 5010 2-1206-P6-001 d C _y ~ _a CONTAINMENT SPRAY g OMCB CONTAINMEN 5012 TRAIN 'A' SPRAY EDUCTOR s M 9017A 2-1206-J6-001 _ C o P 1093 10' 90 A_ 8, 3 REFUELING VATER = 3' PCP STORAGE TANK oprG 2-1204-T4-001 8JL C E, v CONTAINMENT -k M HV QMCB SPRAY EDUCTOR c> r, 10 9017B 2-1206-J6-002 U.52) MCB 9001B MCB HV H M 9017B n 9001B TI a s 1094 M 0939 J n g 09 3 HV ,r-- 9003 TD 8' S 9003 m i CONTAINMENT 7' g XI O SPRAY 2-1206-P6-002 l PI 5011 FROM CONTAINMENT M CONTAINMENT SPRAY 2 12' 7' EMERGENCY SUMP 0975 D-PUMP - TRAIN 'B' M e- @rh G W B08 v1 ISSE rtR PST I L__i-as-es c4 ats urnarts in arvas y eneessa - JC l iC y", C Z'((w'.'"m,,,..,,, bk Southern Company Services, Inc.FOR Southern Nuclear Operating Company c= sri n.= ro to== r-e-ev. ac aci .c a w V0GTLE ELECTRI EgERATING PLANT 8[8 = * " 8 "'c SCALE em CIDffpaKB (Be SM.ET PUMP INSERVICE TESTING LOOP ua 1, a FOR CDNTAINMENT SPRAY PUMP l 2-1206-P6-001 N/A N/A ISI-D-268 10F 1 4

NOTE: THIS IS A SIMPLIFIED ,LC 2" DIAGRAM USED TO DEPICT 2 r, A TEST CIRCUIT. REFER (006) QMCB TO JHE P8.ID FOR DETAILS. j; 4 9003A QMCB QMCB U 9001A M F GM CONTAINMENT HV TI PI 1094 7' ~ m 9001A 0938 0974 PI 12' EMERGENCY SUMP FI __ 0929 TO 0972 12*X10' CONTAINMENT - "'- 1 12*X10* 12' SPRAY 8' }--C o 5010 2-1206-P6-001 0 W__g ~ _s CONTAINMENT SPRAY y QMCB CONTAINMEN 5012 TRAIN *A* SPRAY EDUCTOR s M 9017A 2-1206-J6-001,/, O u 1093 10' 90 A. S 3' 3,

  • REFUELING VATER QPCP STORAGE TANK PE T

uL a 2' O98 2-1204 -T4-001 v Z CONTAINMENT ~[CD M HV QMCB SPRAY EDUCTOR o 2-1206-J6-002 152 go. 9017B MCB 9001B 3 QMCB HV M 9017B r 9001B Tl a ~ 1094 M 0939 2 m g HV r-- 9003 09 3 TD 8' S 9003 I I, g CONTAINMENT 7' Q 0 SPRAY ~~ h011M , CONTAINMENT SPRAY 12' r' ' FROM CONTAINMENT PI EMERGENCY SUMP 0975 -8 PUMP - TRAIN 'B' V5013 M a' I = dI5h aE v. 3.rt av oerg m3casPYuss meeJ mppea appeJ arets appas ajanlas mas vs nsx rm m I t-ES-GB CA. I,LB tr3.TED TU EvJS IF 22493t3 ._)2 = e-w itv su arvrucs v=ves - essest a em -LMs Southern Company Services, Inc.FOR Southern Nuclear Operating Company JJ n-u m vs

== miovra spear ansmvt = a v=vts er,. o c n.,m Ye ro -m ir,. ,v. m .c .c 3 og5 VOGTLE ELECTRI EgERATINGPLANT nsreca n .c scaz a=rous a. s=ri PUMP INSERVICE TESTING LOOP ,.aa. a .tr e erv. 1 FOR CONTAINMENT SPRAY PUMP 2-1206-P6-002 N/A N/A ISI-D-269 1Wl 4

.-.. _ _ ~_. _ _ .. _ _ _ _ _ _ ~. _. _ _. _.. i CVCS Pumps CENTRIFUGAL CHARGINGPUMPS 3 (2-1208-P6-002, & 003) { System Function The primary functions of the CVCS are to: I Regulate reactor coolant chemistry for reactivity and corrosion control I Maintains the water level in the pressurizer of the RCS Maintains seal-water injection flow to the reactor coolant pump Provide a means offilling, draining and pressure testing the RCS 4 Provide injection flow to the RCS following actuation j ofSIS i Quantity 2 Type. Horizontal, centrifugal,11 stage ) Manufacturer /Model Pacific, U 2-1/2 in., RL i j Capacity 150 gpm TotalDynamic Head 5800 ft. C\\ (/ Driver Type Westinghouse electric motor 4 Horsepower 600 3 Speed 1800 rpm j Power Supply 4160V,60 Hz,3 phase J J. Code Class 2 1 Project Class 212 l Outline Drawing 2X6AH02-100 Instruction Book 2X6AH02-85 Physical Location Aux Bldg, Level C, Rooms R-C16 & R-C17 P&ID 2X4DB116-2 Surveillance Procedure 14808-2 Pump Test Loop Diagrams ISI-D-270 & ISI-D-271 O Test Parameter Sheets Page 20-2 & 20-3 20-1 Rev.O

w 3 s ) Test Parameter Table - Pump 2-1208-P6-002 (Figure ISI-D-270) InstInnentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. No.0) Range Req. Ace. Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-8891 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8472 0-4000 12% NA NA NA NA NA i (Po) psig i Differ. Pressure Qtr NA(1) NA 12% APr % - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr F1-10120 0-80 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. A m p. Qtr (2) NA 15% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than sat listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

20-2 Rev.0 [

) s Test Parameter Table - Pump 2-1208-P6-003 (Figure ISI-D-271) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea. I.D. NoJ3) Range Rea. Acc. Yalue Range Range Range Comments j Speed (N) NA NA NA NA NA NA NA NA Constant speed driver i Inlet Pressure Qtr PI-8892 0-100 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-8473 0-4000 12% NA NA NA NA NA i t j (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 er > l.10APr NA t (AP) Flowrate Qtr F1-10121 0-80 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm i Vib. Amp. Qtr (2) NA 15% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s L l i Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instnamentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

F

4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

-[ [ 20-3 Rev.0 1 [ . - - - - - _ - _. - - _ _ - _ _. _ _ _. _ - - - _ _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ - _ _ - _ _, - _ _ - _ - - _ _ _ _ - _ _. _ _ _ -l

.O O)- i b V 4 X3* SEAL VATER LC e 3' 329B N3* ][i l 120 _ 3* 3-RVST 2' h 3* GU l 8110 l 3, VOLUME REACTOR U 3*X2' l . ONgQAg OMCB 2-1208-P6-001 l' COOLANT RHT' /IiSN POSITIVE DISPLACEMENT L L j CHARGING PUMP RHT 4-M SEALS D ll M FD g3 CVCS FV G3D GED 10120 -3*X2-PS 12C 112B REGENERATIVE gN II MCB FT QMC FI 508 if RHT i EXCHANGER /TiSh0MCB 8 2 273 M pg g E 0187 g aMr 8891 = CVCS LUU ? /' i' O' 4 E h , 6* REACTOR O ggi '2-1208-P6-002 ' 013 CDOLANT PUMP RHT g X CENTRIFUGAL H SEALS MCB F 5018 CHARGING PUMP 471 10th! 3*X2 QMCB TRAIN *A* a LRHT QMCB NOTE: THIS IS A H HS 12D SIMPLIFIED DIAGRAM 4g 3* PI b USED TO DEPICT A TEST HV 8473 74 PI MCB RH pg CIRCUIT. REFER TO THE 485 q 018 8 8 *' 8892 A PLI.D. FOR DETAILS. A if E I 6-8'X6* GED S '2-1208-P6-003 k ( ) '48) RHT e508 xI H V Ugp 47l l 2E HV HV TRAIN *B* HSN ( 801A 801B 508 4 71 FROM J LRHT MCB REFUELING TD RCS COLD LEGS RVST VATER STORAGE TANK 8E'A MTE BY Der *B KSCAFTEss arrGJ srPW2 apptJ APPE4 aPPt.S EgaMut3 P N ESS VS IISUE FtEt PST ' I s-es-se ca.

== tenarts u irva y ev4emm-e - JC Ie E ~E"t>YE caers i asern es oma a, Ei Southern Company Services, Inc.FOR Southern Nuclear Operating Company vs n C E My ir w, " '" cams, " " " " " " " " " N VDGTLE ELECTRIC GENERATING PLANT 8t=8 s ,"*,'88"*" y*** UNIT 2 PUMP INSERVICE TESTING LOOP ana m.v .o, av ^ ^ 2 08-P -002 N/A N/A ISI-D-270 1 IF 1 5

Q) %) J 4 X3' SEAL VATER LC 32 B h,1 [i L 12 3 3' ) = 3' H RVST 2' H 3' (IDE)d n 8110 l 3 1 VOLUME 7' v i CVCS 6' 3'X2' l -1 r fyt%^ #T REACTOR MCB 2-1208-P6-001 c e s CDOLANT RHT rr POSITIVE DISPLACEMENT t PUMP 0121 111 CHARGING PUMP ggg RHT 4-Il2B SEALS D ll g FO 112C ll2B CVCS FV (I3D (IEH) 10 20 . -3'X2' PS REGE TIVE gg 121 QMC 508 I RHT_g HS FI MCB EXCHANGER /Tih H OMC y 0MCB h485 8 2 273 PI pg 8891 ggp a 0187 CVCS LOD p / Ie 8'X 4' - M, = 6, (Ig2) p SEALS QMCB ' 6RHT 5018 C G P NOTE: THIS IS A H " OMCB b LV QMCB 101 1 3'X2 g3 5 8-112D SIMPLIFIED DIAGRAM 4 PI 4 73 BS USED TO DEPICT A TEST HV 8473 274 PI MCB RHT pg CIRCUIT. REFER TO THE 485 h I 8892 018 8 P8,I.D. FOR DETAILS. a i 4'l 1 6 8'X6' M O O /P 2-1208-P6-003 g g RHT 508 [XI CENTRIFUGAL H LV i P 1 L J 5019 CHARGING PUMP 4 71 112E HV HV HS 801A 801B 1 @ 508 471 FROM 2 LRHT MCB REFUELING TO RCS COLD LEGS RVST VATER STORAGE TANK av.

== o=, .nc.m -u -2 -as =: 9 WW Elit V5 IISLEB FGt PTT

  • I s-as-se ca.

sto irmus in arv.ns a r:4eam-e -._C iN v~s.S =ur."r>7 ~- anet asus Ps esem a e 55. Southern Company Services, Inc.FOR Southern Nuclear Operating Company ~ EE E E .Yr""c*"*""""**"""" N V0GTLE ELECTRIC GENERATING PLANT K58'*** "e 3 UNIT 2 Z, ym, PUMP INSERVICE TESTING LOOP aua ww. ^ "^ 2 08-P -O03 N/A N/A ISI-D-271 1 (T 1 5

_ _ = _. _ _ _.... _. _ _ _.. _ _ _. _...... BORIC ACID TRANSFER PUMPS 4 (2-1208-P6-006 & 007)

/'

System Function Provides boric acid to the CVCS for use in RCS inventory control and makeup to systems requiring reactor grade borated water. The boric acid transfer system also provides boric acid for emergency boration of the RCS, Quantity 2 l Type Canned motor j Manufacturer /Model Chempump Model GVH-1K i 4 Design Flowrate 75 gpm Design Head 235 ft. ) Driver Type Electric motor kW 15.5 Speed 3450 rpm Power Supply 4160V,60 Hz,3 phase i Code Class 3 .O Project Class 313 Outline Drawing 2X6AH02-45 & 2X6aH02-92 Instruction Book 2X6AA07-10 Physical Location Aux Bldg, Level D, Rooms R-D106 & R-D123 P&lD 2X4DB118 Surveillance Procedure 14811-2 Pump Test Loop Diagrams ISI-D-277 & ISI-D-278 Test Parameter Sheets Page 21-2 & 21-3 0 21 - 1 Rev.O

(4 0(./ V0 Test Parameter Table - Pump 2-1208-P6-006 l (Figure ISI-D-277) [ Instrumentaten Utilized Ref. Acceptable Alert Action Parameter Test Frea. I.D. NoJ3) RanFe Rea. Acc. Value Range Range Range Comments t Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-10115 -15 to +15 12% NA NA NA NA Relief Request RR-P-l l (Pi) psig t Outlet Pressure Qtr PI-0113 0-160 12% NA NA NA NA NA i i (Po) _ psig i Differ. [ Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr FI-40001 0-100 2% Qr NA NA NA Flowrate is set at reference value ( (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr 5 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes: [

1. Differential pressure is calculated as, AP = Po - Pi l
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

j

4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial j

direction on each accessible thrust bearing housing. 21-2 Rev.0 l l t

O O O Test Parameter Table - Pump 2-1208-P6-007 (Figure ISI-D-278) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea, LD. NoJ3) RanFe Rea. Acc-Yalue Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-10116 -15 to +15 i2% NA NA NA NA Relief Request RR-P-1 (Pi) psig Outlet Pressure Qtr PI-Oll4 0-160 12% NA NA NA NA NA i (Po) psig l i Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr FI-40001 0-100 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA i (V)(4) or >.325 in/s >.70 in/s Notes:

1. DilTerential pressure is calculated as, AP = Po - Pi i
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.

i

4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial I

direction on each accessible thrust bearing housing. i l 1 t 21 - 3 Rev.0 i

Q) p] L \\J NOTE THIS IS A V SIMPLIFIED DIAGRAM USED TO DEPICT A TEST CIRCUIT. REFER TO THE (x-800) I P&I.D. FOR DETAILS. TD BORIC FROM BRS RECYCLE LO LD EVAPORATOR b, Z Z 2' ER N Olle N Nl X lll 0 1l 2ma m L1 (1 1 2, D LO LO 1N, K: = lI: M =X 1 e am m I BORIC ACID 000 TRANSFER PUMP LC BORIC ACID FILTER BYPASS 2' BORIC ACID 2-1208-P6-006 2* n 7' TO BORIC ACID BLENDER STORAGE TANK SEE ISI-D-277 N 2-1208-T4-003 3* FUTURE OMCB c28mM'o J L I 114 3' PP 011 , tg ', C N X = 3,>. (O LO L 1, 3 - X e e Mc. e 3-, casa) ce m x x SAMPLE O U 2-1 -P6- 07 B Y ACID TRANSFER PUMPS TO UNIT 1 BORIC TRANSFER PUMP -v. mn e, o.c.

=

-u -u -s

== e e-es-en ct. => rssas rm m i m JJC i wu+ uv .ma uvms un ruw wa JJC e im m M3 mm. m caan m Southern Company Services. Inc. FOR Southern Nuclear Operating Company VDGTLE ELECTRIC GENERATING PLANT==* = n==' c' UNIT 2 o==a =>

==1 carmas a sun PUMP INSERVICE TESTING LOOP FOR esaum a. mu, BORIC ACID TRANSFER PUMP r 2-1208-P6-007 N/A N/A ISI-D-278 1 IT 1 2 L

N/ ,/ NOTE THIS IS A SIMPLIFIED DIAGRAM V USED TO DEPICT A TEST CIRCUIT. REFER TO THE I Pt. L D. FOR DETAILS. (x-90rD FROM BRS RECYCLE Lu LD TO BORIC, EVAPORATOR X X _2 CHRD GU7) 011 [', i X li; o hJ LD 3 r JL i ,m El LA i 1 h >C '; ;,; 2' 2 r 1 e am e I BORIC ACID 000 TRANSFER PUMP LC BORIC ACID 2-1208-P6-007 2' n BORIC ACID FILTER BYPASS 2* STORAGE TANK SEE ISI-D-278 7' TO BORIC ACID BLENDER 2-1208-T4-003 N 3' FUTURE QMC (282)} LO d ' 'I 3' PP 11 3 011 LO LD L =3'> (O 0 N X 1,3,= x e e M c=, e 3' e83) e W s (@ 2-SAMPLE B I Ab Y ACID TRANSFER PUMPS TO UNIT 1 BORIC TRANSFER PUMP =v. mars =v on = = - -. _ -u e n-as-as ct. as tsmas ran en i en JJC was-e+ uv = wvrus un rtow em JJC ~ ~ " ~ ' Southern Company Services, Inc.rOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT = = = < * ^~: naa= ca-UNIT 2 a=* me PUMP INSERVICE TESTING LOOP FOR SEU' wr ~ =ana av. BORIC ACID TRANSFER PUMP 2-1208-P6-006 N/A N/A ISI-D-277 1 (T 1 2

s. 4 AFW Pumps t (2-1302-P4-001,002 & 003) 1/ System Function Supply water to the steam generatore whenever the reactor i coolant temperature is above 350'F and the main feedwater system is not in operation, i.e., during startup, cooldown, or emergency conditions resulting in a loss of main feedwater. c Automatically provides feedwater for the removal of reactor core decay heat following a loss of main feedwater. This prevents damage to the reactor core until the reactor coolant temperature is brought from a Hot Standby condition to the point at which RHR may be placed ir.to j operation. l AFW supplies feedwater to the steam generators at a j flowrate sufficient to support normal low-power transients i such as stanup, cooldown, and hot standby. 4 Turbine Driven AFW Pumo (2-1302-P4-001) j Quantity 1 i a 4 Type Horizontal, centrifugal,5 stage, split-case b i i y Manufacturer /Model Ingersoll-Rand, Model 6HMTA i Capacity 1175 gpm l Total Dynamic Head 3500 ft. 1 Driver 4 i Type Terry Turbine, Model GS-2N, non-condensing, single-i stage, mechanical drive Horsepower 1603 j Speed 4250 rpm Power Supply Steam ) Code Class 3 i + ( Project Class 313 4 i Outline Drawing 2X4AF03-88 Instruction Book 2X4AF03-20031 !O i 22 - 1 Rev.O I

. ~...... Turbine Driven AFW Pumn (2-1302-P4-001) (cond i A lO Physical Location AFW pump house

i V P&ID

~ 2X4DB161-2 I a j Surveillance Procedure 14810-2 Pump Test Loop Diagrams ISI-D-272 t i Test Parameter Sheets Page 22-4 4 1 I l i l i 22 - 2 Rev.0

Motor-Driven AFW Pumos (2-1302-P4-002 & 003) j Quantity 2 1 !h Type Horizontal, centrifugal, 6 stage, split-case v f { Manufacturer /Model Ingersoll-Rand, Model 4HMTB Design Flowrate 630 gpm Total Dynamic Head 3500 ft. Driver Type Westinghouse electric motor, LLD 5810 H Horsepower 900 i Speed 3600 rpm Power Supply 4160V,60 Hz,3 phase Code Class 3 Project Class 313 Outline Drawing 2X4AF03-87 Instruction Book 2X4AF03-20030 0 Physical Location AFW pump house P&ID 2X4DB161-2 Surveillance Procedure 14807-2 Pump Test Loop Diagrams ISI-D-273 & ISI-D-274 Test Parameter Sheets Page 22-5 & 22-6 22 - 3 Rev.O

O O O Test Parameter Table - Pump 2-1302-P4-001 (Figure ISI-D-272) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. LD. No.(3) Range Rea. Acc. Value Range Range Range Comme::ts Speed (N) Qtr SI-15109A 0-6000 12 % Nr NA NA NA Speed is set to reference value Inlet Pressure Qtr PI-5110A 0-30 i2% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-5107A 0-2000 i2% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr F1-15100 0-200 i2% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA 15% Vr 5; 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

22 -4 Rev.0

... _ _ _ _ _. _.... _ _ _ _. _... _. _ _ ~ Test Parameter Table - Pump 2-1302-P4-002 (Figure ISI-D-273) i Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Freq. I.D. No.(3) Rance Req. Acc. Value Ranee Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver [ Inlet Pressure Qtr PI-5128A 0-30 12% NA NA NA NA NA i (Pi) psig i i Outlet Pressure Qtr PI-5140A 0-2000 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) 1 Flowrate Qtr FI-15101 0-200 12% Qr NA NA NA Flowrate is set at reference value I (Q) gpm Vib. Amp. Qtr (2) NA 15% Vr 5 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s r Notes: l 1

1. Differential pressure is calculated as, AP = Po - Pi l
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearmg housing and in the axial i

direction on each accessible thrust bearing housing. k 22-5 Rev.0

o o o Test ParameterTable - Pump 2-1302-P4-003 (Figure ISI-D-274) Instrumentation Utili=1 Ref. Acceptable Alert Action Parameter Test Frea. LD.No.01 Range Reg. Acc. Value Raare Range Rance Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver i inlet i Pressure Qtr PI-5129A +10 12% NA NA NA NA NA (Pi) pug Outlet Pressure Qtr PI-5141 A 0-2000 12% NA NA NA NA NA i (Po) psig j Differ. [ Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr F1-15102 0-200 12% Qr NA NA NA Flowrate is set at reference value I (Q) gpm Vib. Amp. Qtr (2) NA i5% Vr 52.5Vr > 2.5Vr - 6Vr >6Vr or NA i (V)(4) or >.325 in/s >.70 in/s f r Notu: l

1. Di Terential pressure is calculated as, AP = Po - Pi
2. Po: table vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

L 22 - 6 Rev.0 i m

(S (g g N N LD 2.5" CONDENSATE CONDENSATE TE 15 9 510 LD 3*X2 1/2" 2.5" FROM MAIN STORAGE TANK STORAGE TANK 5175 i

    1. MEM 0

2-1302-V4-002 _ 2-1302-V4-001 sy 15133 sg g OMCB 'c3 p 7, 5 3 5110A MCB 5 0 -o _J QMCB 0 I g i 6* cu I \\, i Sf . t j i -@0 0 j \\ T TURBINE DRIVEN COTT) E 2-1302-P4-001 HS AUX FEEDVATER e AUX 0 W PUMP TURBINE 10' / XI T FEEDVATER cu cu NOTE THIS'IS A HV 5113 2-1302-P4-001-K01 PUMP 8[_- SIMPLIFIED DIAGRAM 3[ 5113 TD USED TO DEPICT A TEST T (U5T) ATMOSPHERE FV CIRCUIT. REFER TO THE 10' 5154 M ] [FROM CHEM. ^ 'N ' QMCB H 5140 2 1/2*X2' g' ' INJECTION HV HV 128 MCB 5094 (UDD g (UM) Sj[_5098 4, j lll 8' 8' 8 g LD m 2-1302-P4-002 HV X FV 8 2' 5118 FEED ATER PUMP 5035 5155 y 1 [ g, = 3 OMC HV HS Q 2 1/2*X2* ,2 ' QMCB 131A 5141A ( 5092-- HV I9 y[ HV 5095 g 8* 8'X6' 3 4' U O 'i A' 5099 E 3-- HV LD 2-1302-P4-003 5119 AUX XI 8' g FE g TER 8' _s

  • s-w

== vs usure r= es, FT i im-se et et s ww.ts to acvas a rienesi-a JJC ~ Southern Company Services, Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT KI"'

== "c UNIT 2 [', Z, y_ PUMP INSERVICE TESTING LUDP ui. ,,,1, c. FOR AUXILLARY FEEDVATER PUMP 2-1302-P4 -001 N/A N/A ISI-D-272 10F 1 2 s

S %J %./ L] PV w l -l 4* 3*X21/2 @ 2.5* CONDENSATE CONDENSATE TE 15129 5106 LD FRON MAIN STORAGE TANK STORAGE TANK 5175

  1. NU gG i i 2-1302-V4-002

_ 2-1302-V 4 -001 3 sy { a HV 5093 5110A MCB 5 0 --a l J OMCB / f N D _) '\\ h_jh f4k0 " 0 HS AUX FEEDVATER AUX r n PUMP TURBINE 10' XI FEEDVATER n; ni NOTEi THIS ilS A n[_ HV 5113 -1302-P4-001-K01 PUMP SIMPLIFIED DIAGRAM

Sjd, 5113 TO S

USED TO DEPICT A TEST l ATMOSPHERE FV CIRCUIT. REFER TO THE 10' 5154 'N QMCB H p1 ] ['FROM CHEM. 1/2'X2' e' INJFCTION HV HV 128 2MCB GED A 5094 3[5098 4, q 7 O~h j N 8' 8' 6

4 LO G159)h 2-1302-P4-002 HV

\\ I FV S 2' 5118 FEED ATER 1! PUMP 5155 m 1 [ 8, OMCB W QMC M 2 1/2*X2' 2~ i HV p MCB ' I 131 5141A 5092--o 5129 HV HV -_J 5095 g N 8' 8'X6' I 4, DA' e p 5099 W B 'O (DUT) l LO 7 0 L 2-1302-P4-003 HV -h_ 5119 AUX XI FEgpTER 8' 8' .v . s__ __s e

  • w ses vs issure a est I

-es-se et ei.: trwun m.vn er rnomi-e - JC L Southern Company Services. Inc.FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT 't='

== =c

== vs UNIT 2 PUMP INSERVICE TESTING LOOP ,7r mv FOR AUXILLARY FEEDVATER PUMP 2-1302-P4-002 N/A N/A ISI-D-273 10F 1 2

l i T y SE n 2 5 5 EH a 1 2 2 TT p M m .a, F0 AAO' o R T C gtp I ) ) GT A 9 0 AACR g 7'r O ' DDR 4 6 7 IIE in c 7 / 7 S DPF t " $2 ( ( EE a I r = SE e 7 I D p IIO. O = HF TT I TI I S I L U

  • r I
P D C a

E M ER e g T ISI e, li' OSUC lc A / u N w O 2" N N F / M N) n O6y 1 ) E 0 ) r

  • 2 H

3 e I 2 C 0 h A / T ( 3 X 0 C 2' o u t I / = ( 3' M F o ( N 2 O J S = X R N. 3' FI p R T P F ' O N P M [- 1 ' - i ' I ' r A O U U D ] 2'I ' - c L 1 d O P )L O) hU@h I P ) n ) L 4g3g N 2 G R 5 5 0 0 s N G E 0 0 ( N T 0 I e ( ( ( T I ) c A T A3 'O iv R SV0 6 hm 2' 2' r 0 B 8 E ED X X e ( C S gTE-D 0i l hm 2' E 4 2 EP / / y EF-1 1 n C 2 a I Y 0 r 2 N 2 p R VR3 I '0 m T RA1 hPJmM o C EL-5 N C E SL2 2 E 4 y L NI N V R V5 n E IX Am B E F1 r U I R T 5 e E PA I 5 h L M M C D AP B V5 t T UR M M XVM C, u G M 4 F1 4 PO p(. RN O N E DU o 0 5 F O B N A S V EP C I F M B E B A I R F U M p4 1 P C g g/i I I V6 1 T O 5 H0 1 5 d X E 0 OH f h3 A R 1 E 1 g TP 1 g S 2 3 10 O 6 0 R 0 R 0" R M X 0 0 E E 9 3 E 1T g1 T T V2 y3 Ti 9 8 4 8 8 4 AP P A C 1 P1 g1 Al0 2 P - iJ 5 5 B M I VR0 t J 1 1 2 DU 2 B DU B 0 h 0 C ET+ C P 3 E 3 E t M E M F 1 1 F O FP-Q 2 2 M0 2 8 XU3 8 UP1 A - l 2 I 5 i ) } 8 r E7 3 ) 5 8 T1 ; 1 5 5 0 s e ( 0 5 0 ) ) w ( 6@ 1 s 4 b s. J 3 V9 S1 r 0 e K1 0 5 'N H0 ; 0 H1 ( N 5 5 y E A-V9 i ~ o T T 4 8' H0 v A 0 NE-V3 '0 j 5 n e V S e 1 8 m o " G 2 5 H1 V1 n t E A 5 1 ~ s 0 H1 D R , n 3 5 a a N O1 m o " OT - B O t CS2 ~ i r " s V9 N 2 s s t ~ v a K 2 9 / N 0 H0 0 H0 5 EA 5 8 8' - = e." T T t V9 [3 A 4 T H0 V S E-5 9 e N G V9 e e EA2 [ H0 , s e t " D R 0 5 . s-N O 3 _3 O 1 T - C S2 e i 'l l

-. - = - -. -. -..... ESF Pumps (2-1592-P7-001, & 002) System Function During nonnal operation, the ESF chilled-water system is in ~ standby mode; it is activated during emergency conditions upon receipt of a safety injection signal, containment ventilation isolation, or control room isolation signal. The . ESF chilled-water system serves air handling units located in the safety-related areas of the plant to ensure the integrity of the cooling system during plant emergency situation. Quantity 2 Type Centrifugal Manufacturer Goulds Capacity 600 gpm TotalDynamic Head 125 ft. Driver Type Westinghouse electric motor Horsepower 30 O Speed 1800 rpm j Power Supply 480V,60 Hz,3 phase Code Class 3 - Project Class 313 Outline Drawing 2X4AJ05-28 Instruction Book AX4AJ05-86 Physical Location Control Bldg, EL 260 ft., Rooms R-310 & R-308 P&ID 2X4DB221 Surveillance Procedure 14809-2 Pump Test Loop Diagrams ISI-D-275 & ISI-D-276 Test Parameter Sheets Page 23-2 & 23-3 O 23 - 1 Rev.0

I O O O Test Parameter Table - Pump 2-1592-P7-001 (Figure ISI-D-275) Instrumentation Utilized Ref. Acceptable Alert Action Parameter Test Frea. 1.D. NoJ3) Range Rea. Acc. Yalut Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver inlet Pressure Qtr PI-22410 0-30 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-22414 0-200 12% NA NA NA NA NA i (Po) psig Differ. Pressure Qtr NA(1) NA 12% APr .90 - 1.10APr NA <.90 or >l.10APr NA (AP) Flowrate Qtr F1-22425 0-750 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm Vib. Amp. Qtr (2) NA iS% Vr 5 2.5Vr > 2.5Vr - 6Vr >6Vr or NA (V)(4) or >.325 in/s >.70 in/s Notes:

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial direction on each accessible thrust bearing housing.

23 - 2 Rev.O

O O O Test Parameter Table.- Pump 2-1592-P7-002 (Figure ISI-D-276) Instrumentatian Utili=d Ref. Acceptable Alert Action Parameter Iest Frea. I.D. No.f3) Range Req. As Value Range Range Range Comments Speed (N) NA NA NA NA NA NA NA NA Constant speed driver Inlet Pressure Qtr PI-22411 0-30 12% NA NA NA NA NA (Pi) psig Outlet Pressure Qtr PI-22415 0-200 12% NA NA NA NA NA (Po) psig Differ. Pressure Qtr NA(1) NA i2% APr .90 - 1.10APr NA <.90 or >l.10APr -' NA (AP) Flowrate Qtr FI-22426 0-750 12% Qr NA NA NA Flowrate is set at reference value (Q) gpm ' Vib. I Amp. Qtr (2) NA i5%' Vr s 2.5Vr > 2.5Vr - 6Vr >6Vr or NA or >.325 in/s >.70 in/s (V)(4) i Notes: [

1. Differential pressure is calculated as, AP = Po - Pi
2. Portable vibration instruments are utilized.
3. At the discretion of SNC, instrumentation other than that listed, which meets the requirements of the OM Code, may be utilized for measuring test parameters.
4. Measurements are taken in a plane approximately perpendicular to the rotating shaft in two orthogonal directions on each accessible pump-bearing housing and in the axial

' direction on each accessible thrust bearing housing. l i } 23 - 3 Rev.0 [ t

O O O NOTE: 1. THIS IS A SIMPLIFIED EXPANSION DIAGRAM USED TO DEPICT TANK A TEST CIRCUIT. REFER HVC S 2-1592-T7-001 TO THE Pt.ID FOR 2240 P2412 DETAILS. C 2240 1, (

2. VALVE INTERNALS REMOVED PER DCP IhA 90-V2N0068-0-1 D

f CHEMICAL SDA TI FI FEED PDT. 242 D m p,. t 9 02 PI TI 22 1 1 P 44 2241 22410 5032 9 L N, 1/2' C fl N 6*X4' N 'sm dEVAP.l E @CB ESF CHILLER EMERGENCY I/2' MAKEUP VATER g* 2-1592-C 7-001-000 I 2' 6' Ci r 5030 m, EC' HV Sd k fl 240 CB ESF CHILLED 242 10' VATER PUMP I f (10* 10'% Y 2-1592-P7-001-000 D PROJ. CLASS 313 E' TRAIN 'A' 6' ~ COOLING COILS =v. mm e, o., =_. m. m. 9 WS-te M vs 133E3 FtB PIT

  • ]

se-as ca. ets woms is eva er enma -_C bS E E C.1" b Southern Company Services, Inc. FOR Southern Nuclear Operating Company V0GTLE ELECTRIC GENERATING PLANT smeen n mm. = UNIT 2 =

=== vs PUMP INSERVICE TESTING LOOP "EC' x, ~ -a o FOR CB ESF CHILLED VATER PUMP TRAIN 'A' 2-1592-P7-001-000 N/A N/A ISI-D-275 1 IT I 3

O O O NOTE

1. THIS IS A SIMPLIFIED EXPANSION DIAGRAM USED TO DEPICT TANK A TEST CIRCUIT. REFER C

S 2-1592-T7-00E TO THE P&lD FOR 2240 2413 DETAILS. C

2. VALVE INTERNALS 22401 I,

REMOVED PER DCP IA j 90-V2N0068-0-1 pD CHEMICAL SDB TI FI D FEED POT. 243 4 7' shmn,. t 9 De PI HV TI 243 ' 2441 (U57) g pg g 22411 b $d L @ 3, 1/2" 6' lpp_{)g} _ d EVAP. l N O CB ESF CHILLER O' -002-000 K ATER l 2' 6' c 5 1 mir LC' [HV $d k CB ESF CHILLED 242 fl 2240 VATER PUMP 10' I I 2-1592-P7-002-000 10' 10' PROJ. CLASS 313 b' TRAIN 'B' 6' ~ CDOLING COILS i av. an r, o.c, er _..,,. u 2 9 W BE WS 1EstKB f1R PtY I a s-as-ee et us trairra in svm er asesora - JC 'Ae-M "w2 "'E ~ ' Southern Company Services, Inc. FOR Southern Nuclear Operating Company s VDGTLE ELECTRIC GENERATING PLANT 8m"* UNIT 2 ""*v5 PUMP INSERVICE TESTING LOOP ",,aa. 527 x, FOR CB ESF CHILLED VATER PUMP TRAIN 'B' 2-1592-P7-002-000 N/A N/A ISI-D-276 1 [F 1 3

PUMP RELIEF REQUEST LOG Relief Reauest Number Status RR-P-1 Submitted for NRC Review. RR-P-2. Submitted for NRC Review. RR-G-1 Submitted for NRC Review. RR-G-2 Submitted for NRC Review. i t O O 24-1 Rev.0 =

PUMP RELIEF REQUEST RR-P-1 2 SYSTEM: Chemical Volume and Control System (CVCS) PUMPS: Boric Acid Transfer i 1-1208-P6-006 and -007 and 2-1208-P6-006 and -007 s l CLASS: 3 ) i TEST REQUIREMENT. j ISTB 4.7.1(b)(1) requires the full scale range of analog instmments to be not greater than three times the reference value. i j BASIS FOR RELIEF: Suction pressure gages PI-10115 and PI-10116 have a full scale range o i [ 30 inches of mercury to 15 psig, or -15 psig to 15 psig with an accuracy ofi0.15 psig. Since pressure readings when the pump is running will i i l always be positive, the range ofinterest for IST is 0 - 15 psig.The j actual suction pressure experienced during surveillance testing is approximately 2 psig which results in a maximum allowable range of 0 - l; 6 psig to satisfy the Code requirements. The Code allowable tolerance l j would be 10.12 psig (0.02 x 6). Since the only purpose for measuring j i suction pressure is to use in determining differmtial pressure, for comparison to the test reference value, a total difference of 0.03 (0.15 - t 0.12) psig in the measurement of differential pressure will have no impact on the repeatability or adequacy of the pump test. Therefore, the { existing suction pressure gages provide adequate means for measuring the pump suction pressure and do not jeopardize the adequacy of the j testing being performed. 1 ALTERNATE i ) TESTING: None. The existing suction pressure gages will be utilized for IST of the referenced pumps. l l O i 24-2 Rev.O 1 1

~ PUMP RELIEF REQUEST RR-P-2 SYSTEM-Allincluded in scope ofIST Program PUMPS: j Allincluded in scope ofIST Program CLASS: 2 and 3 I TEST REQUIREMENT: ISTB 6.1 - If deviations fall within the required action range of Table l ISTB 5.2-1, the pump shall be declared inoperable until the cause of the deviation has been determined and the condition corrected 2 BASIS FOR RELIEF: The ASME Section XI Code,1989 Edition, subsection IWP-3230(c) states that; " Corrective action shall be either replacement or repair per IWP-3111, or shall be an analysis to demonstrate that the condition does not impair i i pump operability and that the pump will still fulfill its function. A new set of reference values shall be established after such analysis." 4 l The OMc-1994 Addenda (ISTB 6.2.2) and the OM 1995 ed 6.2.2) both state that; i{( "If the measured test parameter values fall within the required action I_ range of Table 5.2.1-1, Table 5.2.1-2, Table 5.2.2-1, or Table 5.2.3-1, as applicable, the pump shall be declared inoperable until either the cause of i the deviation has been determined and the condition corrected, or an l analysis of the pump is performed and new reference values are established in accordance with ISTB 4.6." l 1 l The Code applicable for the first intervalIST Program (1983 ASME XI), i and the latest issued Code both provide for analysis of pump test data in lieu of repair or replacement of the pump if the test parameters fall within 4 the required action range. The OM Code-1990 Edition did not include such provisions. Communications with members of the OM Code Committee indicate that this was an oversight and that it was never intended to delete the ability to analyze the test data and determine if the i pump is still capable of performing its intended safety function. ALTERNATE 4 TESTING: Should pump test parameters fall within the required action range of Table ISTB 5.2-2 (OM Code 1990 Edition), then the OM Code 1995 Edition, subsection ISTB 6.2.2 will be utilized. Since subsection ISTB 4.6 in the 1995 Code Edition references ISTB 6.2.2, subsection ISTB 4 4.6 from the OM Code 1995 Edition will also be applied. L 24-3 Rev.O

GENERAL RELIEF REQUEST py RR-G-1 SYSTEMS: Allin Scope ofIST Program VALVES: Allin Scope ofIST Program I PUMPS: Allin Scope 7 FIST Program CLASS: 1,2 and 3 TEST REQUIREMENT: The version of 10CFR50 in effect on May 31,1996, paragraph 50.55a(b)(2) ) specifies the applicable Code to be the ASME XI,1988 Addenda through 1989 ) Edition. The 1989 Edition of ASME XI references OM part 6 and 10 for ~ inservice pump and valve testing respectfully. Paragraph 50.55a(b)(2)(viii) of the CFR specifies the Code applicable to inservice pump and valve testing to be the ASME/ ANSI part 6 and ASME/ ANSI part 10 of the OMa-1988 Addenda to the OM-1987 Edition. BASIS FOR 4 RELIEF: The ASME/ ANSI OM document was issued as a Code with the ASME OM Code-1990 Edition. This edition was amended with the OMa Code-1991 Addenda, the OMb Code-1992 Addenda, and the OMc Code-1994 Addenda. The ASME OM Code-1995 Edition was issued in early 1995. With each addenda and edition of the ASME OM Code, the ASME OM Code Committee pg has included updated inservice testing requirements based on improved V knowledge, operating history and experience and changes in testing technology. Beginning with the ASME OM Code-1990 Edition, the format of the document was also changed to read like a Code instead of a standard as it was initially drafted. Therefore, application oflater versions of the ASME OM Code, than specified in 10CFR50, should enhance the quality of the IST Program. i ALTERNATE TESTING: The ASME OM Codes utilized for update of the Vogtle Inservice Testing Program shall be: IST of Valves (except safety / relief valves)- ASME OM Code-1990 Edition IST of Pumps - ASME OM Code-1990 Edition IST of Safety / Relief Valves - ASME OM Code 1995 Edition (ASME OM Code-1995 Edition, Appendix I, augments the rules of Stabsection ISTC 4.4.) The NRC previously approved use of the above referenced Codes in a letter dated November 27,1996. This relief request is identical to RR-G-1 included in the IST Valve Program. Q y F 24-4 Rev. O

l GENERAL RELIEF REQUEST RR-G-2 l SYSTEMS: Allin Scope of Unit 2 IST Program VALVES: Allin Scope of Unit 2 IST Program PUMPS: Allin Scope of Unit 2 IST Program CLASS: 1,2 and 3 TEST 1 REQUIREMENT: The version of 10CFR50 in effect on May 31,1996, paragraph 50.55a(f)(4)(ii), specifies that inservice testing to verify operational readiness of pumps and valves required for. safety, conducted during successive 120-month intervals must comply with the requirements of the latest edition and addenda of the Code incorporated by reference in paragraph 10CFR50.55a(b) 12 months prior to the start of the 120-month interval. BASIS FOR RELIEF: The commercial operation date for Vogtle Unit I was May 31,1987. The commercial operation date for Vogtle Unit 2 was May 20,1989. Maintaining both units on the same interval schedule allows both IST programs to be developed utilizing the same edition of the applicable Codes, will make it easier for involved personnel to become familiar with the Code requirements, will O-ensure a greater degree of consistency for IST between the units, and will reduce the cost associated with surveillance arocedure revisions for the program update and for maintenance of the program c ocuments. ALTERNATE. TESTING: Update the Vogtle Nuclear Plant Unit 2 IST Program concurrent with the Unit I second 10-year interval IST Program update due on May 31,1997. The Unit 2 IST Program will be updated concurrent with the Unit 1 IST Program in accordance with the applicable regulations for the remainder of the plant life. The NRC previously approved use of the above referenced Codes in a letter dated November 27,1996. This relief request is identical to RR-G-1 included in the IST Valve Program. i 4 i O 4 24-5 Rev. O i 1}}