{{#Wiki_filter:}} | {{#Wiki_filter:NEI 99-01 Rev 7 Draft B - Summary of proposed decommissioning EALs 4/20/2021 Decommissioning Facility ICs/EALs - Recognition Category D Initiating Condition Matrix Key Appendix C to NEI 99-01 Rev 6 and based on recent precedents* | ||
Applicability to Decommissioning Levels: Post-Shutdown (PS), Permanently Defueled (PD), | |||
ISFSI-Only (IO) | |||
* For PD and IO levels: EAL schemes based on Rev 6 Appendix C submitted for prior NRC approval. | |||
For PS level: Licensees for plants shutdown since 2013 continued to use EALs applicable to Defueled or All Modes from Recognition Categories A, C, E, and H with appropriate operator aids. | |||
Unusual Event Alert Site Area Emergency General Emergency PD-AU1: PD PD-AA1: PD -- -- | |||
D-AU1: PS, PD D-AA1: PS, PD D-AS1: PS D-AG1: PS Rad release Rad release Rad release Rad release PD-AU2: PD PD-AA2: PD D-AU2: PS, PD D-AA2: PS, PD Loss of SFP level AND Rise in plant rad levels rise in plant rad levels impeding plant access PD-SU1: PD D-CU1: PS, PD SFP temperature rise D-CU2: PS Loss of communications PD-HU1: PD, IO PD-HA1: PD, IO -- | |||
D-HU1: PS, PD, IO D-HA1: PS, PD, IO D-HS1: PS Confirmed Security Hostile Action within Hostile Action within Condition or threat Owner Controlled Area Protected Area PD-HU2: PD D-HU2: PS, PD Hazardous event affecting equipment needed for SFP cooling PD-HU3: PD, IO PD-HA3: PD, IO -- -- | |||
D-HU3: PS, PD, IO D-HA3: PS, PD, IO D-HS3: PS D-HG3: PS Judgment of the Judgment of the Judgment of the Judgment of the Emergency Director Emergency Director Emergency Director Emergency Director E-HU1: All Modes (PD, IO) | |||
PS, PD, IO Section 8 ISFSI Damage to loaded cask}} |
Revision as of 11:35, 9 September 2021
ML21106A251 | |
Person / Time | |
---|---|
Issue date: | 04/20/2021 |
From: | Leslie Fields Licensing Processes Branch |
To: | |
Fields L | |
References | |
Download: ML21106A251 (1) | |
Text
NEI 99-01 Rev 7 Draft B - Summary of proposed decommissioning EALs 4/20/2021 Decommissioning Facility ICs/EALs - Recognition Category D Initiating Condition Matrix Key Appendix C to NEI 99-01 Rev 6 and based on recent precedents*
Applicability to Decommissioning Levels: Post-Shutdown (PS), Permanently Defueled (PD),
ISFSI-Only (IO)
For PS level: Licensees for plants shutdown since 2013 continued to use EALs applicable to Defueled or All Modes from Recognition Categories A, C, E, and H with appropriate operator aids.
Unusual Event Alert Site Area Emergency General Emergency PD-AU1: PD PD-AA1: PD -- --
D-AU1: PS, PD D-AA1: PS, PD D-AS1: PS D-AG1: PS Rad release Rad release Rad release Rad release PD-AU2: PD PD-AA2: PD D-AU2: PS, PD D-AA2: PS, PD Loss of SFP level AND Rise in plant rad levels rise in plant rad levels impeding plant access PD-SU1: PD D-CU1: PS, PD SFP temperature rise D-CU2: PS Loss of communications PD-HU1: PD, IO PD-HA1: PD, IO --
D-HU1: PS, PD, IO D-HA1: PS, PD, IO D-HS1: PS Confirmed Security Hostile Action within Hostile Action within Condition or threat Owner Controlled Area Protected Area PD-HU2: PD D-HU2: PS, PD Hazardous event affecting equipment needed for SFP cooling PD-HU3: PD, IO PD-HA3: PD, IO -- --
D-HU3: PS, PD, IO D-HA3: PS, PD, IO D-HS3: PS D-HG3: PS Judgment of the Judgment of the Judgment of the Judgment of the Emergency Director Emergency Director Emergency Director Emergency Director E-HU1: All Modes (PD, IO)