ML21106A251: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
Line 15: Line 15:


=Text=
=Text=
{{#Wiki_filter:NEI 99-01 Rev 7 Draft B - Summary of proposed decommissioning EALs                                4/20/2021 Decommissioning Facility ICs/EALs - Recognition Category D Initiating Condition Matrix Key      Appendix C to NEI 99-01 Rev 6 and based on recent precedents*
{{#Wiki_filter:}}
Applicability to Decommissioning Levels: Post-Shutdown (PS), Permanently Defueled (PD),
ISFSI-Only (IO)
* For PD and IO levels: EAL schemes based on Rev 6 Appendix C submitted for prior NRC approval.
For PS level: Licensees for plants shutdown since 2013 continued to use EALs applicable to Defueled or All Modes from Recognition Categories A, C, E, and H with appropriate operator aids.
Unusual Event                      Alert              Site Area Emergency      General Emergency PD-AU1: PD                    PD-AA1: PD                  --                        --
D-AU1: PS, PD                  D-AA1: PS, PD                D-AS1: PS                D-AG1: PS Rad release                    Rad release                  Rad release              Rad release PD-AU2: PD                    PD-AA2: PD D-AU2: PS, PD                  D-AA2: PS, PD Loss of SFP level AND          Rise in plant rad levels rise in plant rad levels      impeding plant access PD-SU1: PD D-CU1: PS, PD SFP temperature rise D-CU2: PS Loss of communications PD-HU1: PD, IO                PD-HA1: PD, IO              --
D-HU1: PS, PD, IO              D-HA1: PS, PD, IO            D-HS1: PS Confirmed Security            Hostile Action within        Hostile Action within Condition or threat            Owner Controlled Area        Protected Area PD-HU2: PD D-HU2: PS, PD Hazardous event affecting equipment needed for SFP cooling PD-HU3: PD, IO                PD-HA3: PD, IO              --                        --
D-HU3: PS, PD, IO              D-HA3: PS, PD, IO            D-HS3: PS                D-HG3: PS Judgment of the                Judgment of the              Judgment of the          Judgment of the Emergency Director            Emergency Director          Emergency Director        Emergency Director E-HU1: All Modes (PD, IO)
PS, PD, IO              Section 8 ISFSI Damage to loaded cask}}

Revision as of 17:26, 8 September 2021

NEI 99-01 Rev 7 Draft B - Summary of Proposed Decommissioning EALs
ML21106A251
Person / Time
Issue date: 04/20/2021
From: Leslie Fields
Licensing Processes Branch
To:
Fields L
References
Download: ML21106A251 (1)


Text