ML17313A575: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17313A575
| number = ML17313A575
| title = Forwards LER 98-003-01,per 10CFR50.73.Revised LER Provides Cause & Corrective Action for Delay in Bypassing Failed Instrument Used in PPS
| title = Forwards LER 98-003-01,per 10CFR50.73.Revised LER Provides Cause & Corrective Action for Delay in Bypassing Failed Instrument Used in PPS
| release date = 07/31/2018
| package contents = {{Adams package content
| package contents = {{Adams package content
| number = ML17313A576
| number = ML17313A576
| issue date = 09/08/1998
| issue date = 09/08/1998
| title = Forwards LER 98-003-01,per 10CFR50.73.Revised LER Provides Cause & Corrective Action for Delay in Bypassing Failed Instrument Used in PPS
| title = LER 98-003-01:on 980113,discovered That One Channel of RWT Level Sys Had Failed High.Caused by Water Intrusion Into Electrical Termination Pull Box.Weep Holes Were Drilled Into Bottoms of Pull Boxes Nearest Level Transmitters
| author name = MARKS D G
| author name = Marks D
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
| addressee name =  
| addressee name =  
Line 21: Line 22:
| issue date = 09/08/1998
| issue date = 09/08/1998
| title = Forwards LER 98-003-01,per 10CFR50.73.Revised LER Provides Cause & Corrective Action for Delay in Bypassing Failed Instrument Used in PPS
| title = Forwards LER 98-003-01,per 10CFR50.73.Revised LER Provides Cause & Corrective Action for Delay in Bypassing Failed Instrument Used in PPS
| author name = OVERBECK G R
| author name = Overbeck G
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
| addressee name =  
| addressee name =  

Latest revision as of 09:47, 7 March 2020

Forwards LER 98-003-01,per 10CFR50.73.Revised LER Provides Cause & Corrective Action for Delay in Bypassing Failed Instrument Used in PPS
Date released: 07/31/2018 Download: ML17313A575


LER 98-003-01:on 980113,discovered That One Channel of RWT Level Sys Had Failed High.Caused by Water Intrusion Into Electrical Termination Pull Box.Weep Holes Were Drilled Into Bottoms of Pull Boxes Nearest Level Transmitters
ML17313A576
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 09/08/1998
From: Marks D
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
References
Download: ML17313A576 (12)
Forwards LER 98-003-01,per 10CFR50.73.Revised LER Provides Cause & Corrective Action for Delay in Bypassing Failed Instrument Used in PPS
ML17313A574
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 09/08/1998
From: Overbeck G
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17313A574 (4)