ML17313A660: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
Line 6: Line 6:
| number = ML17313A661
| number = ML17313A661
| issue date = 10/24/1998
| issue date = 10/24/1998
| title = Forwards LER 98-008-00,re Condition Where C-E Qualification Repts Used to Qualify Litton-Veam Electrical Connectors for in-core Instrumentation Used in C-E Plants Which May Not Adequately Demonstrate Appropriate Equipment Qualification
| title = LER 98-008-00:on 980729,EQ of Electrical Connectors Were Not Adequately Demonstrated.Caused Because Test Was Conducted with Only Single Lv Connector & Without Fully Ranged Inputs. Revised EQ Requirements
| author name = Marks D
| author name = Marks D
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR

Latest revision as of 10:43, 7 March 2020

Forwards LER 98-008-00,re Condition Where C-E Qualification Repts Used to Qualify Litton-Veam Electrical Connectors for in-core Instrumentation Used in C-E Plants Which May Not Adequately Demonstrate Appropriate Equipment Qualification
Date released: 07/31/2018 Download: ML17313A660


LER 98-008-00:on 980729,EQ of Electrical Connectors Were Not Adequately Demonstrated.Caused Because Test Was Conducted with Only Single Lv Connector & Without Fully Ranged Inputs. Revised EQ Requirements
ML17313A661
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 10/24/1998
From: Marks D
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
References
Download: ML17313A661 (12)
Forwards LER 98-008-00,re Condition Where C-E Qualification Repts Used to Qualify Litton-Veam Electrical Connectors for in-core Instrumentation Used in C-E Plants Which May Not Adequately Demonstrate Appropriate Equipment Qualification
ML17313A659
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 10/24/1998
From: Overbeck G
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17313A659 (2)