ML19225B010: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 6: | Line 6: | ||
| number = ML19225B014 | | number = ML19225B014 | ||
| issue date = 07/18/1979 | | issue date = 07/18/1979 | ||
| title = | | title = LER 79-036/03X-1 on 790602:six Snubbers Found Inoperable. Caused By:Two Had Loose Bolts in Clamps & Four Had Low Fluid Level Due to Leaking Seals.First Two Were Realigned & Bolts Tightened | ||
| author name = Tollison A | | author name = Tollison A | ||
| author affiliation = CAROLINA POWER & LIGHT CO. | | author affiliation = CAROLINA POWER & LIGHT CO. |
Latest revision as of 01:00, 24 January 2020
Date released: 08/27/2019 | Download: ML19225B010 |
---|---|
ML19225B014 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 07/18/1979 |
From: | Tollison A CAROLINA POWER & LIGHT CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19225B014 (1) | |
ML19225B009 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 07/18/1979 |
From: | Banks H CAROLINA POWER & LIGHT CO. |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19225B009 (1) | |