Line 6: Line 6:
| number = ML19253B416
| number = ML19253B416
| issue date = 09/27/1979
| issue date = 09/27/1979
| title = Forwards Final Deficiency Rept Re Steam Generator Water Level Ref Column Error
| title = Final Deficiency Rept Re Steam Generator Water Level Ref Column Error.Caused by Design oversight.Low-low Water Level Setpoint Will Be Adjusted Before Unit 1 Fuel Loading
| author name =  
| author name =  
| author affiliation = TENNESSEE VALLEY AUTHORITY
| author affiliation = TENNESSEE VALLEY AUTHORITY

Latest revision as of 19:51, 23 January 2020

Forwards Final Deficiency Rept Re Steam Generator Water Level Ref Column Error
Date released: 09/24/2019 Download: ML19253B414


Final Deficiency Rept Re Steam Generator Water Level Ref Column Error.Caused by Design oversight.Low-low Water Level Setpoint Will Be Adjusted Before Unit 1 Fuel Loading
ML19253B416
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 09/27/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19253B416 (1)
Forwards Final Deficiency Rept Re Steam Generator Water Level Ref Column Error
ML19253B413
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 09/27/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References