ML19257B995: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 6: | Line 6: | ||
| number = ML19257B997 | | number = ML19257B997 | ||
| issue date = 01/14/1980 | | issue date = 01/14/1980 | ||
| title = | | title = LER 79-113/03L-0:on 791219,during Reactor Startup,Rhr Torus Suction Valve F004C Found Shut During Shift Turnover,Causing RHR Pump to Be Inoperable.Caused by Failure to Manually Return Valve to Correct Position After Shutdown Cooling | ||
| author name = Tollison A | | author name = Tollison A | ||
| author affiliation = CAROLINA POWER & LIGHT CO. | | author affiliation = CAROLINA POWER & LIGHT CO. |
Latest revision as of 15:20, 23 January 2020
Date released: 09/28/2019 | Download: ML19257B995 |
---|---|
ML19257B997 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 01/14/1980 |
From: | Tollison A CAROLINA POWER & LIGHT CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19257B997 (2) | |
ML19257B994 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 01/14/1980 |
From: | Tollison A CAROLINA POWER & LIGHT CO. |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19257B994 (1) | |