ML19263A841: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 21: Line 21:
| number = ML19263A852
| number = ML19263A852
| issue date = 12/28/1978
| issue date = 12/28/1978
| title = Forwards LER 78-033/01T-0
| title = LER 78-033/01T-0 on 781214:reactor Scram Occurred in Range 1 of Intermediate Range Monitor Sys.Caused by Failure of Emergency Rod in Switch Due to Bent Switch Stop
| author name = Ross D
| author name = Ross D
| author affiliation = JERSEY CENTRAL POWER & LIGHT CO.
| author affiliation = JERSEY CENTRAL POWER & LIGHT CO.

Latest revision as of 11:32, 23 January 2020

Forwards LER 78-033/01T-0
Date released: 10/08/2019 Download: ML19263A841


Forwards LER 78-033/01T-0
ML19267A266
Person / Time
Site: Oyster Creek
Issue date: 12/28/1978
From: Ross D
JERSEY CENTRAL POWER & LIGHT CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19267A266 (1)
LER 78-033/01T-0 on 781214:reactor Scram Occurred in Range 1 of Intermediate Range Monitor Sys.Caused by Failure of Emergency Rod in Switch Due to Bent Switch Stop
ML19263A852
Person / Time
Site: Oyster Creek
Issue date: 12/28/1978
From: Ross D
JERSEY CENTRAL POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19263A852 (1)