| title = Forwards LER 79-019/03L-0
| title = LER 79-019/03L-0 on 790524:vacuum Breaker 1-1601-32D Failed to Give Closed Indication.Caused by Binding on Valve Stem Not Allowing Disk to Shut.Defective Bushing & End Packing on Valve Stem Replaced
| author name = Leech K
| author name = Leech K
| author affiliation = COMMONWEALTH EDISON CO.
| author affiliation = COMMONWEALTH EDISON CO.

Latest revision as of 09:51, 23 January 2020

Forwards LER 79-019/03L-0
Date released: 10/10/2019 Download: ML19269E312


LER 79-019/03L-0 on 790524:vacuum Breaker 1-1601-32D Failed to Give Closed Indication.Caused by Binding on Valve Stem Not Allowing Disk to Shut.Defective Bushing & End Packing on Valve Stem Replaced
ML19269E314
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 06/15/1979
From: Leech K
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19269E314 (3)
Forwards LER 79-019/03L-0
ML19269E311
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 06/15/1979
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19269E311 (1)