Items subject to this Fisher Information Notice (FIN) were provided to Tennessee Valley Authority (TVA) Watts Bar Nuclear Plant per TvA Order 702507 (Fisher Order Number 025 -
Items subject to this Fisher Information Notice (FIN) were provided to Tennessee Valley Authority (TVA) Watts Bar Nuclear Plant per TvA Order 702507 (Fisher Order Number 025 -
N230331922). Specifically, this FIN applies to a plug/stem assembly that Fisher Controls International LLC (Fisher) supplied to TVA, item number 15A2560X072 (Equipment). In this Equipment, the essential-to-function groove pin was erroneously *provided as commercial-grade.
N230331922). Specifically, this FIN applies to a plug/stem assembly that Fisher Controls International LLC (Fisher) supplied to TVA, item number 15A2560X072 (Equipment). In this Equipment, the essential-to-function groove pin was erroneously *provided as commercial-grade.
Purpose:
 
==Purpose:==
The purpose of this FIN is to alert the customer that, as of 22 January 2016, Fisher became aware of a situation which may affect the p~rformance of the aforementioned Equipment, including its safety-related function.
The purpose of this FIN is to alert the customer that, as of 22 January 2016, Fisher became aware of a situation which may affect the p~rformance of the aforementioned Equipment, including its safety-related function.
Fisher is informing the customer of this circumstance in accordance with Section 21.21 (b) of 10 CFR21.
Fisher is informing the customer of this circumstance in accordance with Section 21.21 (b) of 10 CFR21.
Line 70: Line 71:
Items subject to this Fisher Information Notice (FIN) were provided to Tennessee Valley Authority (TVA) Watts Bar Nuclear Plant per TvA Order 702507 (Fisher Order Number 025 -
Items subject to this Fisher Information Notice (FIN) were provided to Tennessee Valley Authority (TVA) Watts Bar Nuclear Plant per TvA Order 702507 (Fisher Order Number 025 -
N230331922). Specifically, this FIN applies to a plug/stem assembly that Fisher Controls International LLC (Fisher) supplied to TVA, item number 15A2560X072 (Equipment). In this Equipment, the essential-to-function groove pin was erroneously *provided as commercial-grade.
N230331922). Specifically, this FIN applies to a plug/stem assembly that Fisher Controls International LLC (Fisher) supplied to TVA, item number 15A2560X072 (Equipment). In this Equipment, the essential-to-function groove pin was erroneously *provided as commercial-grade.
Purpose:
 
==Purpose:==
The purpose of this FIN is to alert the customer that, as of 22 January 2016, Fisher became aware of a situation which may affect the p~rformance of the aforementioned Equipment, including its safety-related function.
The purpose of this FIN is to alert the customer that, as of 22 January 2016, Fisher became aware of a situation which may affect the p~rformance of the aforementioned Equipment, including its safety-related function.
Fisher is informing the customer of this circumstance in accordance with Section 21.21 (b) of 10 CFR21.
Fisher is informing the customer of this circumstance in accordance with Section 21.21 (b) of 10 CFR21.

Revision as of 17:13, 4 December 2019

Emerson Process Management, LLC - Part 21 Report Regarding Groove Pin Dedication, Per Watts Bar
ML16084A302
Person / Time
Site: Watts Bar  Tennessee Valley Authority icon.png
Issue date: 03/18/2016
From: Engle C
Emerson Process Management, Fisher Controls International
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
FIN 2016-03
Download: ML16084A302 (4)


Text

.,.

l'>

~

~

~-

EMERSON .. Fisher Controls International LLC Process Management: 301 South First Ave P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830.

Fisher Information Notice: FIN 2016-03 18 March 2016

Subject:

Groove Pin Dedication Equipment Affected by* this Information Notice:

Items subject to this Fisher Information Notice (FIN) were provided to Tennessee Valley Authority (TVA) Watts Bar Nuclear Plant per TvA Order 702507 (Fisher Order Number 025 -

N230331922). Specifically, this FIN applies to a plug/stem assembly that Fisher Controls International LLC (Fisher) supplied to TVA, item number 15A2560X072 (Equipment). In this Equipment, the essential-to-function groove pin was erroneously *provided as commercial-grade.

Purpose:

The purpose of this FIN is to alert the customer that, as of 22 January 2016, Fisher became aware of a situation which may affect the p~rformance of the aforementioned Equipment, including its safety-related function.

Fisher is informing the customer of this circumstance in accordance with Section 21.21 (b) of 10 CFR21.

Applicability:

This FIN applies only to the Equipment supplied by Fisher to TVA Watts Bar via the aforementioned order.

Discussion:

Thi? supplied Equipment in question features a plug tip which is connected to the plug by a simple threaded joint. A groove pin is used to prevent the plug tip from unscrewing from the plug block (please see attached Item 1for pa~ identification). Because the threaded joint is not self-locking, the groove pin serves as a primary locking device. It is therefore considered essential-to-function and requires dedication per FMP2K27 (Control of Commercial Grade Items to be Dedicated for Use in Nuclear Safety-Related Applications). However, review of the documentation package reveals that the groove pin was not subjected to the requirements of FMP2K27; thus, the part was supplied as a commercial'-grade item.

,.

"ft;

~

~

~*

EMERSON .. Fisher Controls International LLC Process Management 301 South First Ave P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 Fisher has no reason to believe the groove pin supplied is defective, only that the part was not properly processed. Th~ part in question does not pose an inherent safety risk and there are no known field issues with the affected Equipment.

Action Required:

Fisher will provide TVA with a properly dedicated groove pin. In addition, a Corrective Action Request (CAR 1796) has been initiated by Fisher to prevent reoccurrence of this issue.

10 CFR 21 Implications:

Fisher requests that the recipient of this FIN review it and take appropriate action in accordance with 10 CFR 21. If there are any technical questions* or concerns, please contact:

Ben Ahrens Quality Manager Emerson Process Management Fisher Controls International LLC 301 South First Avenue Marshalltown, IA 50158 Phone: (641) 754-2249 Benjamin.ahrens@emerson.com

{!;S~ <;

Nuclear Business Unit Director Fisher Controls International LLC 301 South First Avenue Marshalltown, IA 50158 Fax: (641) 754-2854

'\

Item 1 Part Identification Sketch Plug Block: ASME Code Part Part 16A2&80X072 Plug Tip: Dedicated Part TVA PO 702607 Soft Seats Dedicat ed Part Groove Pini Dedicated Part Stem Connection

\ _ Plug Tip (Green)

Soft Seat (Blue)

Plug Block Groove Pin (Orange)


~----

  • NRC's Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

.,.

l'>

~

~

~-

EMERSON .. Fisher Controls International LLC Process Management: 301 South First Ave P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830.

Fisher Information Notice: FIN 2016-03 18 March 2016

Subject:

Groove Pin Dedication Equipment Affected by* this Information Notice:

Items subject to this Fisher Information Notice (FIN) were provided to Tennessee Valley Authority (TVA) Watts Bar Nuclear Plant per TvA Order 702507 (Fisher Order Number 025 -

N230331922). Specifically, this FIN applies to a plug/stem assembly that Fisher Controls International LLC (Fisher) supplied to TVA, item number 15A2560X072 (Equipment). In this Equipment, the essential-to-function groove pin was erroneously *provided as commercial-grade.

Purpose:

The purpose of this FIN is to alert the customer that, as of 22 January 2016, Fisher became aware of a situation which may affect the p~rformance of the aforementioned Equipment, including its safety-related function.

Fisher is informing the customer of this circumstance in accordance with Section 21.21 (b) of 10 CFR21.

Applicability:

This FIN applies only to the Equipment supplied by Fisher to TVA Watts Bar via the aforementioned order.

Discussion:

Thi? supplied Equipment in question features a plug tip which is connected to the plug by a simple threaded joint. A groove pin is used to prevent the plug tip from unscrewing from the plug block (please see attached Item 1for pa~ identification). Because the threaded joint is not self-locking, the groove pin serves as a primary locking device. It is therefore considered essential-to-function and requires dedication per FMP2K27 (Control of Commercial Grade Items to be Dedicated for Use in Nuclear Safety-Related Applications). However, review of the documentation package reveals that the groove pin was not subjected to the requirements of FMP2K27; thus, the part was supplied as a commercial'-grade item.

,.

"ft;

~

~

~*

EMERSON .. Fisher Controls International LLC Process Management 301 South First Ave P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 Fisher has no reason to believe the groove pin supplied is defective, only that the part was not properly processed. Th~ part in question does not pose an inherent safety risk and there are no known field issues with the affected Equipment.

Action Required:

Fisher will provide TVA with a properly dedicated groove pin. In addition, a Corrective Action Request (CAR 1796) has been initiated by Fisher to prevent reoccurrence of this issue.

10 CFR 21 Implications:

Fisher requests that the recipient of this FIN review it and take appropriate action in accordance with 10 CFR 21. If there are any technical questions* or concerns, please contact:

Ben Ahrens Quality Manager Emerson Process Management Fisher Controls International LLC 301 South First Avenue Marshalltown, IA 50158 Phone: (641) 754-2249 Benjamin.ahrens@emerson.com

{!;S~ <;

Nuclear Business Unit Director Fisher Controls International LLC 301 South First Avenue Marshalltown, IA 50158 Fax: (641) 754-2854

'\

Item 1 Part Identification Sketch Plug Block: ASME Code Part Part 16A2&80X072 Plug Tip: Dedicated Part TVA PO 702607 Soft Seats Dedicat ed Part Groove Pini Dedicated Part Stem Connection

\ _ Plug Tip (Green)

Soft Seat (Blue)

Plug Block Groove Pin (Orange)


~----

  • NRC's Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001