NOC-AE-14003120, CFR 50.46 Annual Report of Emergency Core Cooling System (ECCS) Model Revisions: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 26: Line 26:
This includes items such as modifying input variable definitions, units and defaults; improving the input diagnostic checks; enhancing the code output; optimizing active coding; and eliminating inactive coding. The nature of these changes leads to an estimated PCT impact of 0°F.A change in the methodology used to calculate grid blockage ratio and porosity for Westinghouse fuel resulted in a change to the grid inputs used in the 1981 Appendix K Large Break Loss of Coolant Accident (LOCA) Evaluation Model with BASH (BASH-EM), which affects the grid heat transfer in the LOCBART fuel rod heatup calculation.
This includes items such as modifying input variable definitions, units and defaults; improving the input diagnostic checks; enhancing the code output; optimizing active coding; and eliminating inactive coding. The nature of these changes leads to an estimated PCT impact of 0°F.A change in the methodology used to calculate grid blockage ratio and porosity for Westinghouse fuel resulted in a change to the grid inputs used in the 1981 Appendix K Large Break Loss of Coolant Accident (LOCA) Evaluation Model with BASH (BASH-EM), which affects the grid heat transfer in the LOCBART fuel rod heatup calculation.
The change in methodology does not affect the BASH-EM methodology.
The change in methodology does not affect the BASH-EM methodology.
The impact of the recalculated grid blockage ratio and porosity for 17x17 RFA and 17x17 RFA-2 fuel, used as input in the BASH-EM LOCBART model, was qualitatively evaluated as having a negligible impact on reported results, leading to an estimated PCT effect of 0°F.An error in the minimum local strain required for burst for ZIRLO cladding in the SBLOCTA code resulted in 0°F change in PCT. The coding does not enforce reaching the minimum percent local strain threshold prior to calculating fuel rod burst. However, a review of licensing basis analyses revealed no instances of this error impacting calculated results. Based on a review of current licensing basis analyses, and the phenomena and physics of a small break LOCA transient, it is concluded that this error has a negligible effect on small break LOCA analysis results, leading to an estimated PCT impact of 0°F.STP Unit 1 and Unit 2 large break LOCA peak clad temperatures have not changed since submittal in Reference  
The impact of the recalculated grid blockage ratio and porosity for 17x17 RFA and 17x17 RFA-2 fuel, used as input in the BASH-EM LOCBART model, was qualitatively evaluated as having a negligible impact on reported results, leading to an estimated PCT effect of 0°F.An error in the minimum local strain required for burst for ZIRLO cladding in the SBLOCTA code resulted in 0°F change in PCT. The coding does not enforce reaching the minimum percent local strain threshold prior to calculating fuel rod burst. However, a review of licensing basis analyses revealed no instances of this error impacting calculated results. Based on a review of current licensing basis analyses, and the phenomena and physics of a small break LOCA transient, it is concluded that this error has a negligible effect on small break LOCA analysis results, leading to an estimated PCT impact of 0°F.STP Unit 1 and Unit 2 large break LOCA peak clad temperatures have not changed since submittal in Reference
: 1. STP Unit 1 and Unit 2 small break LOCA peak clad temperatures have not changed since submittal in Reference 2.There are no commitments in this letter.If there are any questions, please contact either Mr. Charles Albury at (361) 972-8901 or me at (361) 972-7743.Roland Dunn Manager, Nuclear Fuel & Analysis NOC-AE-14003120 Page 3 of 3 cc: (paper copy)(electronic copy)Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8 B1)11555 Rockville Pike Rockville, MD 20852 NRC Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MN116 Wadsworth, TX 77483 Jim Collins City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 Attention:
: 1. STP Unit 1 and Unit 2 small break LOCA peak clad temperatures have not changed since submittal in Reference 2.There are no commitments in this letter.If there are any questions, please contact either Mr. Charles Albury at (361) 972-8901 or me at (361) 972-7743.Roland Dunn Manager, Nuclear Fuel & Analysis NOC-AE-14003120 Page 3 of 3 cc: (paper copy)(electronic copy)Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8 B1)11555 Rockville Pike Rockville, MD 20852 NRC Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MN116 Wadsworth, TX 77483 Jim Collins City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 Attention:
Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Balwant K. Singal U. S. Nuclear Regulatory Commission John Ragan Chris O'Hara Jim von Suskil NRG South Texas LP Kevin Polio Cris Eugster L. D. Blaylock City Public Service Peter Nemeth Crain Caton & James, P.C.C. Mele City of Austin Richard A. Ratliff Texas Department of State Health Services Robert Free Texas Department of State Health Services}}
Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Balwant K. Singal U. S. Nuclear Regulatory Commission John Ragan Chris O'Hara Jim von Suskil NRG South Texas LP Kevin Polio Cris Eugster L. D. Blaylock City Public Service Peter Nemeth Crain Caton & James, P.C.C. Mele City of Austin Richard A. Ratliff Texas Department of State Health Services Robert Free Texas Department of State Health Services}}

Revision as of 09:38, 28 April 2019

CFR 50.46 Annual Report of Emergency Core Cooling System (ECCS) Model Revisions
ML14112A459
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 04/15/2014
From: Dunn R F
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NOC-AE-14003120, STI:33852592
Download: ML14112A459 (3)


Text

Nuclear Operating Company[J IF-AW South Tcuas Pro/ect Electric Generating Station PO. B&x 289 Wadsworth, Texas 77483 April 15, 2014 NOC-AE-14003120 File No.: G25 10 CFR 50.46 STI:33852592 Attention:

Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50-499 10 CFR 50.46 Annual Report of ECCS Model Revisions

References:

1. Letter from Roland Dunn to NRC Document Control Desk, "10 CFR 50.46 ECCS Evaluation Model Significant Change/Error Report," dated October 17, 2012 (NOC-AE-1 2002912) (ML1 231 0A383)2. Letter from D.A Leazar to NRC Control Desk, "1 OCFR50.46 Annual Report of ECCS Model Revisions," dated May 3, 2004, (NOC-AE-04001722) (ML041450310)

Pursuant to 10 CFR 50.46(a)(3)(ii), STP Nuclear Operating Company submits this report to address errors to the accepted Emergency Core Cooling System (ECCS) evaluation model for the South Texas Project (STP) Units 1 and 2. The following summarize these errors and impact on the calculated Peak Clad Temperature (PCT) for the limiting ECCS analysis.An error in the LOCBART code that impacts the calculation of the rod-to-rod radiation heat transfer coefficient resulted in 0°F change in PCT. The error was corrected and test cases were performed to determine the potential impact on the results. The test case results demonstrated that correcting the code error had a negligible impact on calculated results. Validation testing showed a negligible impact on calculated results, leading to an estimated PCT impact of 0°F.Two errors in the SATAN6 calculation of the radiation term of the fuel rod gap heat transfer coefficient resulted in 0°F change in PCT. First, an incorrect temperature is used in the cladding emissivity calculation; second, a geometrical term is missing from the radiation heat transfer coefficient calculation.

A set of hand calculations was completed showing a negligible impact on the fuel rod gap heat transfer coefficient in SATAN6, leading to an estimated effect of 0°F on PCT.A condition in calculations completed with the BASH computer code relating to an isotherm indexing variable in the quench front model that results in oscillatory quench front behavior above the peak power elevation for select cases resulted in 0°F change in PCT. An updated version of the BASH computer code was used to estimate the effect of the quench front oscillations on the resulting core inlet flooding rate used by LOCBART for calculating the PCT.Aocwa NOC-AE-14003120 Page 2 of 3 An updated version of the BASH computer code was developed to assess the impact of the oscillations for all impacted analyses.

The validation results show a negligible impact on the resulting core inlet flooding rate, leading to an estimated effect of 0°F on PCT.Various changes have been made to enhance the usability of the codes and to help preclude errors in analyses.

This includes items such as modifying input variable definitions, units and defaults; improving the input diagnostic checks; enhancing the code output; optimizing active coding; and eliminating inactive coding. The nature of these changes leads to an estimated PCT impact of 0°F.A change in the methodology used to calculate grid blockage ratio and porosity for Westinghouse fuel resulted in a change to the grid inputs used in the 1981 Appendix K Large Break Loss of Coolant Accident (LOCA) Evaluation Model with BASH (BASH-EM), which affects the grid heat transfer in the LOCBART fuel rod heatup calculation.

The change in methodology does not affect the BASH-EM methodology.

The impact of the recalculated grid blockage ratio and porosity for 17x17 RFA and 17x17 RFA-2 fuel, used as input in the BASH-EM LOCBART model, was qualitatively evaluated as having a negligible impact on reported results, leading to an estimated PCT effect of 0°F.An error in the minimum local strain required for burst for ZIRLO cladding in the SBLOCTA code resulted in 0°F change in PCT. The coding does not enforce reaching the minimum percent local strain threshold prior to calculating fuel rod burst. However, a review of licensing basis analyses revealed no instances of this error impacting calculated results. Based on a review of current licensing basis analyses, and the phenomena and physics of a small break LOCA transient, it is concluded that this error has a negligible effect on small break LOCA analysis results, leading to an estimated PCT impact of 0°F.STP Unit 1 and Unit 2 large break LOCA peak clad temperatures have not changed since submittal in Reference

1. STP Unit 1 and Unit 2 small break LOCA peak clad temperatures have not changed since submittal in Reference 2.There are no commitments in this letter.If there are any questions, please contact either Mr. Charles Albury at (361) 972-8901 or me at (361) 972-7743.Roland Dunn Manager, Nuclear Fuel & Analysis NOC-AE-14003120 Page 3 of 3 cc: (paper copy)(electronic copy)Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8 B1)11555 Rockville Pike Rockville, MD 20852 NRC Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MN116 Wadsworth, TX 77483 Jim Collins City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 Attention:

Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Balwant K. Singal U. S. Nuclear Regulatory Commission John Ragan Chris O'Hara Jim von Suskil NRG South Texas LP Kevin Polio Cris Eugster L. D. Blaylock City Public Service Peter Nemeth Crain Caton & James, P.C.C. Mele City of Austin Richard A. Ratliff Texas Department of State Health Services Robert Free Texas Department of State Health Services