{{Adams
#REDIRECT [[05000247/LER-2016-010]]
| number = ML17003A008
| issue date = 12/21/2016
| title = LER 16-010-00 for Indian Point, Unit 2 Regarding Safety System Functional Failure Due to an Inoperable Containment Caused by a Through Wall Defect in a Service Water Supply Pipe Elbow to the 24 Fan Cooler Unit
| author name = Vitale A J
| author affiliation = Entergy Nuclear Operations, Inc, Indian Point Energy Center
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR
| docket = 05000247
| license number = DPR-026
| contact person =
| case reference number = NL-16-140
| document report number = LER 16-010-00
| document type = Letter, Licensee Event Report (LER)
| page count = 7
}}