ENS 42083: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
| facility = Honeywell International, Inc.
| facility = Honeywell International, Inc.
| Organization =  
| Organization =  
| license number = Sub-526
| license number = SUB-526
| region = 2
| region = 2
| state = Illinois
| state = Illinois
Line 16: Line 16:
| event date = 10/25/2005 15:00 CDT
| event date = 10/25/2005 15:00 CDT
| last update date = 10/26/2005
| last update date = 10/26/2005
| title = Violation Of Ansi Standard For Uf6 Cylinders
| title = Violation of Ansi Standard for Uf6 Cylinders
| event text = Metropolis Works, Metropolis, Illinois (MTW) is reporting a failure to follow procedure related to the installation of valves in UF6 cylinders.
| event text = Metropolis Works, Metropolis, Illinois (MTW) is reporting a failure to follow procedure related to the installation of valves in UF6 cylinders.
A violation of ANSI Standard N14.1 (2001) 'Uranium Hexafluoride Packaging for Transport', Section 6.14.6 was reported 26 October, 2005. This is a reportable event because it is a violation of an applicable national standard and also an action outside the licensee's procedures.  ANSI N14-1 (2001) 6.14.6 states, 'No material of any kind other than the specified solder shall be used on the threads to facilitate installation {of cylinder valves into the UH6 type 48Y cylinders}.'  Contrary to that standard, MTW site maintenance personnel did use Teflon spray to facilitate installation of cylinder valves into type 48Y cylinders. Use of a thread lubricant, such as Teflon, can be expected to increase the degree the valve threads are engaged for a given torque.  Teflon is a fluorinated compound and is not a chemical hazard in contact with UF6.
A violation of ANSI Standard N14.1 (2001) 'Uranium Hexafluoride Packaging for Transport', Section 6.14.6 was reported 26 October, 2005. This is a reportable event because it is a violation of an applicable national standard and also an action outside the licensee's procedures.  ANSI N14-1 (2001) 6.14.6 states, 'No material of any kind other than the specified solder shall be used on the threads to facilitate installation {of cylinder valves into the UH6 type 48Y cylinders}.'  Contrary to that standard, MTW site maintenance personnel did use Teflon spray to facilitate installation of cylinder valves into type 48Y cylinders. Use of a thread lubricant, such as Teflon, can be expected to increase the degree the valve threads are engaged for a given torque.  Teflon is a fluorinated compound and is not a chemical hazard in contact with UF6.

Latest revision as of 18:36, 24 November 2018

ENS 42083 +/-
Where
Honeywell International, Inc.
Metropolis, Illinois (NRC Region 2)
License number: SUB-526
Reporting
Other Unspec Reqmnt
Time - Person (Reporting Time:+21.92 h0.913 days <br />0.13 weeks <br />0.03 months <br />)
Opened: Jame Tortorelli
17:55 Oct 26, 2005
NRC Officer: Arlon Costa
Last Updated: Oct 26, 2005
42083 - NRC Website