ENS 47420: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
| facility = Curwood, Inc
| facility = Curwood, Inc
| Organization = Iowa Department Of Public Health
| Organization = Iowa Department Of Public Health
| license number = 3003177Fg
| license number = 3003177FG
| region = 3
| region = 3
| state = Iowa
| state = Iowa
Line 16: Line 16:
| event date = 11/02/2011 CST
| event date = 11/02/2011 CST
| last update date = 11/07/2011
| last update date = 11/07/2011
| title = Agreement State Report - Nuclear Gauge Dislodged From Mounting
| title = Agreement State Report - Nuclear Gauge Dislodged from Mounting
| event text = The following report was received via e-mail:
| event text = The following report was received via e-mail:
Curwood, Inc. reported an incident involving a NDC Infrared Engineering, Inc. thickness gauge, model 103, serial number 13457, containing 150 mCi's of Americium-241 that occurred on November 2, 2011.  A sample of film was cut from the web on a production line and as the sample passed the device, the tail snagged the gauge and dislodged it from the mounting bracket.  The gauge fell approximately 40 inches to the treater deck platform.  The fall caused the shutter to become dislodged from the device and the crystal lens was cracked.  Curwood contacted NDC and was instructed to perform a survey and wipe test of the device.  The survey and wipe test indicated that the source was intact and no removable contamination was present.  The device is currently packaged and in storage awaiting shipment to NDC for repair.  The cause of this incident was the fact that the sample was taken prior to the device and that one of the two screws mounting the device was missing.  Corrective actions include now taking the samples at a location on the production line after the device, replacing and securing the missing screw, [performing] a daily spot check of the mounting screws, and a weekly check of the screws to ensure that they are secure.
Curwood, Inc. reported an incident involving a NDC Infrared Engineering, Inc. thickness gauge, model 103, serial number 13457, containing 150 mCi's of Americium-241 that occurred on November 2, 2011.  A sample of film was cut from the web on a production line and as the sample passed the device, the tail snagged the gauge and dislodged it from the mounting bracket.  The gauge fell approximately 40 inches to the treater deck platform.  The fall caused the shutter to become dislodged from the device and the crystal lens was cracked.  Curwood contacted NDC and was instructed to perform a survey and wipe test of the device.  The survey and wipe test indicated that the source was intact and no removable contamination was present.  The device is currently packaged and in storage awaiting shipment to NDC for repair.  The cause of this incident was the fact that the sample was taken prior to the device and that one of the two screws mounting the device was missing.  Corrective actions include now taking the samples at a location on the production line after the device, replacing and securing the missing screw, [performing] a daily spot check of the mounting screws, and a weekly check of the screws to ensure that they are secure.

Latest revision as of 19:18, 24 November 2018

ENS 47420 +/-
Where
Curwood, Inc
Des Moines, Iowa (NRC Region 3)
License number: 3003177FG
Organization: Iowa Department Of Public Health
Reporting
Agreement State
Time - Person (Reporting Time:+126.27 h5.261 days <br />0.752 weeks <br />0.173 months <br />)
Opened: Randal Dahlin
13:16 Nov 7, 2011
NRC Officer: Mark Abramovitz
Last Updated: Nov 7, 2011
47420 - NRC Website