WBL-23-023, Of Cycle 19 Core Operating Limit Report
ML23117A026 | |
Person / Time | |
---|---|
Site: | Watts Bar |
Issue date: | 04/27/2023 |
From: | Anthony Williams Tennessee Valley Authority |
To: | Office of Nuclear Reactor Regulation, Document Control Desk |
References | |
WBL-23-023 | |
Download: ML23117A026 (1) | |
Text
TENNESSEE VALLEY
' AUTHORITY
Pos t Offic e Box 2000, Sprin g City, T e nn essee 3738 1
WBL-23-023
April 27, 2023
ATTN : Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001
Watts Bar Nuclear Plant, Unit 1 Facility Operating License No. NPF -90 NRC Docket No. 50-390
Subje ct: REVISION O OF THE UNIT 1 CYCLE 19 CORE OPERATING LIMITS REPORT (COLR)
Pursuant to Watts Bar Nuclear Plant Technical Specifications Section 5.9.5.d, Tennessee Valley Authority (TVA) has enclosed Revision O of the Unit 1 Cycle 19 Co re Operating Limits Report (COLR). The analytical methods used to determine the core operating limits were previously reviewed and approved by the NRC.
There are no new regulatory commitments contained in this letter o r the enclosure. Should yo u have questions regarding this submittal, please contact Jonathan Johnson, Site Licensing Manager, at jtjohnson0@tva.gov.
~ - -
Anthony L. Williams, IV Site Vice President Watts Bar Nuclear Plant U.S. Nuclear Regulatory Commission WBL-23-023 Page 2 April 27, 2023
Enclosure Watts Bar Nuclear Plant, Unit 1, Cycle 19 Core Operating Limits Report, Revision 0, April 2023
cc: (w/ enclosure)
NRC Regional Administrator - Region II NRC Project Manager - Watt Bar Nuclear Plant NRC Senior Resident Inspector - Watts Bar Nuclear Plant
ENCLOSURE
Watts Bar Nuclear Plant, Unit 1, Cycle 19 Core Operating Limits Report Revision 0 April 2023
QA Record L36 230223 800
WATTS BAR NUCLEAR PLANT, UNIT 1, CYCLE 19
CORE OPERATING LIMITS REPORT
Revision 0
March 2023
Prepared by:
Crawley =:::..~ca:..Mlln, oi,11aa,t111Mdbrl"ort9,MlrlDonlld ' ::c:.:=..":.~ Porter, Mark Donald =.-:=":::.~*-
- ---- --- ----------------Olivia =~::=.-11.:wdocument Dm:20D.OJJnll:SSM-05'DCI' 1 Olivia G. Crawley, Mark D. Porter, PWR Fuel Engineering Date
Verified by :
~llyllgnedt,yhll,J,inelC 0
_B_ e_ l_l,_J_a_ m __ e_l_ C ____ ~_:_,,;_~_,.. -_~~-~:_":__"_~"'_-_... -_~ *_-_,._,,,.,_ __ ~'------
Jamel C. Bell, PWR Fue l Engineering Date
Reviewed by:
Dlgftally signed by Rltchle,John A ON: dc=gov, dc-tva, de-main, ou=Main, au-Corporate, ou=Usl!!n, cn=Rltchle, John A, emall=JarltchleOOtva.gov Ritchie, John A ~~~; 3~0=:!s~ument / _ ___ _ _
John A. Ritchie, Manager, PWR Fuel Engineering Date Ma Ck, Bryan Th Om a S Digitally signed by Mack, Bryan Thomas Date: 2023.03.06 10:01:10 -05'00' Bryan T. Mack, Manager, Reactor Engineering Date
Approved by :
~.......;~;;......=:__~....;;;_o ____ ~ __ o _iol_, _g__ U4-____ _____,, oa-oe* 2.c:523 PORC Chairman Date
Date of PORC Affected Revision Aooroval Paaes Reason for Revision 0 See above All Initial issue
Unit 1 Cycle 19 WATTS BAR Page 1 of 13 Revision 0 1.0 CORE OPERATING LIMITS REPORT
This Core Operating Limits Report (COLR) for Watts Bar Unit 1 Cycle 19 has been prepared in accordance with the requirements of the Technical Specifications 5.9.5.
The Technical Specifications affected by this report are listed below:
3.1.4 Moderator Temperature Coefficient (MTC) 3.1.5 Rod Group Alignment Limits 3.1.6 Shutdown Bank Insertion Limits 3.1.7 Control Bank Insertion Limits 3.2.1 Heat Flux Hot Channel Factor (FQ(Z))
3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (FHN) 3.2.3 Axial Flux Difference (AFD) 3.9.1 Boron Concentration
2.0 OPERATING LIMITS
The cycle-specific parameter limits for the specifications listed in section 1.0 are presented in the following subsections. These limits have been developed using the NRC approved methodologies specified in the Technical Specifications Section 5.9.5.
The following abbreviations are used in this section:
BOL -- Beginning of Cycle Life ARO -- All Rods Out HZP -- Hot Zero Thermal Power EOL -- End of Cycle Life RTP -- Rated Thermal Power ROS -- RAOC Operating Space RA -- Required Action
2.1 MODERATOR TEMPERATURE COEFFICIENT - MTC (LCO 3.1.4)
2.1.1 The MTC limits are:
The ARO/HZP - MTC shall be less positive than or equal to 0 k/k/ °F (upper limit).
With the BOL/ARO/HZP - MTC more positive than -2.095 x 10-5 k/k/°F (BOL MTC limit), establish control rod withdrawal limits to ensure the MTC remains less positive than or equal to 0 k/k/ °F (upper limit) for all times in core life.
The EOL/ARO/RTP - MTC shall be less negative than or equal to
-4.5 x 10-4 k/k/°F (lower limit).
2.1.2 The 300 ppm surveillance limit is:
The 300 ppm /ARO/RTP-MTC should be less negative than or equal to
-3.75 x 10-4 k/k/°F.
Unit 1 Cycle 19 WATTS BAR Revision 0 2.1.3 The 60 ppm surveillance limit is:
The measured 60 ppm /ARO/RTP-MTC should be less negative than or equal to
-4.28 x 10-4 k/k/°F.
2.2 SHUTDOWN MARGIN - SDM (LCO 3.1.5, 3.1.6, 3.1.7)
2.2.1 Fo r TS 3.1.5, SDM shall be 1.6% k/k in MODE 1 and MODE 2.
2.2.2 For T S 3.1.6, SDM shall be 1.6% k/k in MODE 1 and MODE 2.
2.2.3 For TS 3.1.7, SDM shall be 1.6% k/k in MODE 1 and MODE 2 with keff 1.0.
2.3 SHUT DOWN BANK INSERTION LIMITS (LCO 3.1.6)
2.3.1 The shutdown ba nks shall be withdrawn to a position greater than or equal to 224 steps withdrawn.
2.4 CONTROL BANK INSERTION LIMITS (LCO 3.1.7)
2.4.1 The control banks are fully withdrawn or shall be limited in physica l insertion as shown in Figure 1.
2.4.2 Each control bank shall be considered fully withdrawn from the core at greater than or equal to 224 steps.
2.4.3 The control banks shall be operated in sequence by withdrawal of Bank A, Bank B, Bank C, and Bank D. The control banks shall be sequenced in reverse order upon insertion.
2.4.4 Each control bank not fully withdrawn from the core shall be operated with the following overlap as a function of park position.
Park Position (steps) Bank Overlap (steps) Bank Difference(steps) 224 108 116 225 109 116 226 110 116 227 111 116 228 112 116 229 113 116 230 114 116 231 115 116
Unit 1 Cycle 19 WATTS BAR Revision 0 2.5 HEAT FLUX HOT CHANNEL FACTOR - F Q(Z) (LCO 3.2.1)
FQ(Z) [CFQ / P]
- K(Z) for P > 0.5
FQ(Z) [CFQ / 0.5]
- K(Z) for P 0.5
Where P = Thermal Power / Rated Thermal Power
2.5.1 CFQ = 2.50
2.5.2 K(Z) is provided in Figure 2.
2.5.3 () = 1.03 () 1 +
100 where 1.03 is the fuel manufacturing tolerance,
() is the measured value of () and is the measurement uncertainty ( 5).
2.5.4 () equations are:
() 1.03 [()] () ( ) > 0.5 1 + 100
() 1.03 [()] () ( ) 0.5 0.5 1 + 100
Where () is the measured planar radial peaking factor.
() evaluations are not applicable for axial core regions, measured in percent of core height:
- a. Lower core region, from 0 to 10% inclusive,
- b. Upper core region, from 90 to 100% inclusive,
- c. Grid plane regions, +2% inclusive, and
- d. Core plane regions, within 2% of the bank demand positions of the control banks.
2.5.5 [()] values are provided in Tables A.1 and A.2 for ROS 1 and ROS 2, respectively.
2.5.6 () factors adjust the surveillance to the reference conditions assumed in generating the [ ()]factors. () may be assumed to be equal to 1.0 or may be determined for specific surveillance conditions using the approved methods listed in TS 5.9.5.
2.5.7 The penalty factors account for the potential decrease in transient FQ margin between surveillances. The factors for ROS 1 and ROS 2 are provided in Tables A.3 and A.4 respectively.
2.5.8 Table A.5 provides the required limits on THERMAL POWER and the required AFD reductions for each ROS in the event that additional margin is required.
Unit 1 Cycle 19 WATTS BAR Revision 0 2.6 NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR - F H N (LCO 3.2.2)
FHN FHRTP * ( 1 + PF * ( 1-P))
where P = Thermal Power / Rated Thermal Power
FHRTP = 1.65 for RFA-2 fuel
PF = 0.3
2.7 AXIAL FLUX DIFFERENCE - AFD (LCO 3.2.3)
2.7.1 The AFD limits for RAOC operating spaces (ROS 1 and ROS 2) and corresponding AFD reduction limits (RA-1 and RA-2) are provided in Figure 3.
2.8 REFUELING BORON CONCENTRATION (LCO 3.9.1)
2.8.1 The refueling boron concentration shall be 2300 ppm.
3.0 NUMBER OF TPBARS IN REACTOR CORE (TS 4.2.1)
3.0.1 There are 1 792 tritium producing burnable absorber rods (TPBARs) in the reactor core for Cycle 19.
Unit 1 Cycle 19 WATTS BAR Revision 0 Figure 1 Control Bank Insertion Limits Versus Thermal Power Four Loop Operation
Note: Ful ly withdrawn region shall be the condition where shutdown and control banks are at a position within the interval of 224 and 231 steps withdrawn.
Unit 1 Cycle 19 WATTS BAR Revision 0 1.2
1.1
1
0.9
0.8
0.7
0.6 Core Height K(Z) 0.000 1.000 0.5 6.000 1.000 12.000 1.000
0.4
0.3
0.2
0.1
0 0 1 2 3 4 5 6 7 8 9 10 11 12 Core Height (feet)
Figure 2 K(Z) - Normalized FQ(Z) as a Function of Core Height
Unit 1 Cycle 19 WATTS BAR Revision 0 Figure 3 Axial Flux Difference Acceptable Operation Limits as a function of Rated Thermal Power (RAOC)
Unit 1 Cycle 19 WATTS BAR Revision 0 Table A.1
[()] Factors for ROS 1
Height (ft) 150 MWD/MTU 4000 MWD/MTU 8000 MWD/MTU 12000 MWD/MTU 14000 MWD/MTU 18000 MWD/MTU 12.0720 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.8708 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.6696 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.4684 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.2672 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.0660 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 10.8648 0.9796 0.9230 0.9580 1.0419 1.0744 1.1355 10.6636 1.0442 0.9999 1.0417 1.1230 1.1493 1.1986 10.4624 1.1460 1.1090 1.1499 1.2256 1.2555 1.2860 10.2612 1.1735 1.1527 1.1884 1.2542 1.2714 1.3002 10.0600 1.1248 1.1256 1.1572 1.2109 1.2256 1.2472 9.8588 1.1405 1.1559 1.1828 1.2207 1.2322 1.2469 9.6576 1.2263 1.2457 1.2664 1.2941 1.2991 1.2978 9.4564 1.2408 1.2639 1.2858 1.2987 1.3020 1.2949 9.2552 1.1828 1.2107 1.2344 1.2454 1.2468 1.2347 9.0540 1.1601 1.1942 1.2128 1.2157 1.2174 1.2074 8.8528 1.2475 1.2808 1.2856 1.2820 1.2780 1.2651 8.6516 1.3083 1.3406 1.3377 1.3283 1.3204 1.3033 8.4504 1.2826 1.3161 1.3168 1.3015 1.2971 1.2820 8.2492 1.2278 1.2628 1.2667 1.2465 1.2449 1.2346 8.0480 1.2954 1.3286 1.3261 1.2970 1.2942 1.2811 7.8468 1.3550 1.3870 1.3772 1.3373 1.3333 1.3181 7.6456 1.3229 1.3564 1.3460 1.3031 1.3000 1.2878 7.4444 1.2487 1.2843 1.2761 1.2343 1.2329 1.2260 7.2432 1.2748 1.3073 1.2952 1.2465 1.2437 1.2366 7.0420 1.3574 1.3865 1.3615 1.3014 1.2956 1.2854 6.8408 1.3775 1.4065 1.3714 1.3032 1.2946 1.2850 6.6396 1.3112 1.3458 1.3081 1.2436 1.2333 1.2256 6.4384 1.2960 1.3335 1.2887 1.2238 1.2120 1.2006 6.2372 1.3809 1.4169 1.3553 1.2803 1.2637 1.2425 6.0360 1.3993 1.4323 1.3610 1.2839 1.2645 1.2372 5.8348 1.3331 1.3670 1.2997 1.2246 1.2060 1.1810 5.6336 1.2851 1.3204 1.2523 1.1802 1.1582 1.1393 5.4324 1.3634 1.3947 1.3180 1.2346 1.2109 1.1815 5.2312 1.4162 1.4444 1.3642 1.2719 1.2468 1.2155 5.0300 1.4085 1.4359 1.3594 1.2658 1.2415 1.2127 4.8288 1.4005 1.4280 1.3549 1.2625 1.2374 1.2095 4.6276 1.4053 1.4320 1.3618 1.2701 1.2444 1.2179 4.4264 1.4209 1.4458 1.3785 1.2873 1.2630 1.2334 4.2252 1.3988 1.4235 1.3638 1.2795 1.2564 1.2261 4.0240 1.3161 1.3426 1.2971 1.2283 1.2076 1.1807 3.8228 1.3122 1.3365 1.2989 1.2385 1.2180 1.1896 3.6216 1.3787 1.3978 1.3618 1.3051 1.2838 1.2471 3.4204 1.3903 1.4069 1.3790 1.3277 1.3124 1.2726 3.2192 1.3680 1.3820 1.3669 1.3260 1.3171 1.2793 3.0180 1.3514 1.3639 1.3619 1.3347 1.3270 1.2918 2.8168 1.3520 1.3679 1.3707 1.3663 1.3541 1.3207 2.6156 1.3605 1.3754 1.3869 1.4017 1.3914 1.3620 2.4144 1.3192 1.3308 1.3563 1.3909 1.3879 1.3682 2.2132 1.2306 1.2412 1.2824 1.3379 1.3437 1.3451 2.0120 1.2427 1.2462 1.3000 1.3751 1.3881 1.3917 1.8108 1.2754 1.2696 1.3344 1.4290 1.4491 1.4627 1.6096 1.2248 1.2127 1.2887 1.4027 1.4324 1.4625 1.4084 1.1456 1.1276 1.2108 1.3396 1.3781 1.4249 1.2072 1.0806 1.0553 1.1423 1.2843 1.3316 1.3967 1.0060 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.8048 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.6036 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.4024 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.2012 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Unit 1 Cycle 19 WATTS BAR Revision 0 Table A.2
[()] Factors for ROS 2
Height (ft) 150 MWD/MTU 4000 MWD/MTU 8000 MWD/MTU 12000 MWD/MTU 14000 MWD/MTU 18000 MWD/MTU 12.0720 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.8708 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.6696 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.4684 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.2672 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 11.0660 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 10.8648 0.9796 0.9185 0.9427 1.0323 1.0554 1.1118 10.6636 1.0442 0.9945 1.0270 1.1138 1.1284 1.1780 10.4624 1.1460 1.1056 1.1411 1.2168 1.2304 1.2666 10.2612 1.1735 1.1527 1.1862 1.2467 1.2592 1.2835 10.0600 1.1248 1.1255 1.1552 1.2052 1.2163 1.2342 9.8588 1.1406 1.1559 1.1829 1.2169 1.2318 1.2343 9.6576 1.2235 1.2457 1.2664 1.2826 1.2991 1.2845 9.4564 1.2337 1.2639 1.2858 1.2885 1.3008 1.2803 9.2552 1.1771 1.2107 1.2325 1.2405 1.2447 1.2320 9.0540 1.1606 1.1849 1.2087 1.2152 1.2148 1.2074 8.8528 1.2473 1.2613 1.2829 1.2820 1.2757 1.2651 8.6516 1.3083 1.3180 1.3352 1.3283 1.3189 1.3033 8.4504 1.2826 1.2939 1.3133 1.3015 1.2943 1.2820 8.2492 1.2278 1.2414 1.2619 1.2465 1.2416 1.2346 8.0480 1.2954 1.3083 1.3195 1.2970 1.2901 1.2811 7.8468 1.3550 1.3687 1.3685 1.3373 1.3285 1.3181 7.6456 1.3229 1.3420 1.3357 1.3031 1.2949 1.2878 7.4444 1.2487 1.2741 1.2646 1.2343 1.2278 1.2260 7.2432 1.2748 1.3022 1.2817 1.2465 1.2384 1.2366 7.0420 1.3574 1.3846 1.3457 1.3014 1.2900 1.2854 6.8408 1.3775 1.4064 1.3498 1.3032 1.2890 1.2850 6.6396 1.3112 1.3458 1.2902 1.2436 1.2279 1.2256 6.4384 1.2960 1.3335 1.2751 1.2238 1.2076 1.2006 6.2372 1.3809 1.4169 1.3472 1.2803 1.2599 1.2425 6.0360 1.3993 1.4324 1.3594 1.2839 1.2618 1.2375 5.8348 1.3333 1.3658 1.2997 1.2246 1.2043 1.1782 5.6336 1.2819 1.3148 1.2520 1.1802 1.1574 1.1379 5.4324 1.3533 1.3848 1.3121 1.2336 1.2055 1.1802 5.2312 1.3991 1.4291 1.3508 1.2677 1.2400 1.2080 5.0300 1.3865 1.4156 1.3402 1.2595 1.2334 1.1985 4.8288 1.3721 1.3999 1.3306 1.2533 1.2279 1.1907 4.6276 1.3739 1.3994 1.3323 1.2576 1.2325 1.1932 4.4264 1.3845 1.4068 1.3435 1.2712 1.2462 1.2043 4.2252 1.3586 1.3798 1.3243 1.2586 1.2353 1.1933 4.0240 1.2745 1.2985 1.2552 1.2023 1.1832 1.1456 3.8228 1.2667 1.2904 1.2520 1.2061 1.1886 1.1503 3.6216 1.3275 1.3473 1.3118 1.2639 1.2461 1.2046 3.4204 1.3314 1.3501 1.3260 1.2815 1.2617 1.2282 3.2192 1.3075 1.3221 1.3095 1.2777 1.2648 1.2320 3.0180 1.3033 1.2990 1.3054 1.2836 1.2716 1.2419 2.8168 1.3115 1.2989 1.3169 1.3056 1.2903 1.2642 2.6156 1.3211 1.3056 1.3346 1.3333 1.3193 1.2984 2.4144 1.2794 1.2625 1.3053 1.3213 1.3135 1.3016 2.2132 1.1927 1.1772 1.2336 1.2688 1.2689 1.2768 2.0120 1.2034 1.1817 1.2499 1.3021 1.3080 1.3181 1.8108 1.2340 1.2038 1.2824 1.3510 1.3629 1.3827 1.6096 1.1843 1.1500 1.2379 1.3244 1.3448 1.3801 1.4084 1.1069 1.0694 1.1625 1.2633 1.2918 1.3426 1.2072 1.0434 1.0001 1.0963 1.2098 1.2463 1.3141 1.0060 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.8048 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.6036 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.4024 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.2012 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Unit 1 Cycle 19 WATTS BAR Revision 0 Table A.3 Rj Margin Decrease Factors for ROS 1
Cycle Burnup Rj Cycle Burnup Rj Cycle Burnup Rj (MWD/MTU) (MWD/MTU) (MWD/MTU) 150 1.0000 7727 1.0096 15304 1.0000 339 1.0000 7916 1.0093 15493 1.0000 529 1.0000 8106 1.0091 15683 1.0000 718 1.0021 8295 1.0087 15872 1.0000 908 1.0054 8485 1.0083 16061 1.0000 1097 1.0081 8674 1.0123 16251 1.0000 1287 1.0102 8863 1.0116 16440 1.0000 1476 1.0118 9053 1.0108 16630 1.0000 1665 1.0133 9242 1.0099 16819 1.0000 1855 1.0147 9432 1.0089 17009 1.0000 2044 1.0153 9621 1.0084 17198 1.0000 2234 1.0152 9811 1.0103 17387 1.0000 2423 1.0146 10000 1.0120 17577 1.0000 2612 1.0134 10189 1.0091 17766 1.0000 2802 1.0118 10379 1.0108 17956 1.0000 2991 1.0100 10568 1.0125 18145 1.0003 3181 1.0080 10758 1.0141 18334 1.0002 3370 1.0061 10947 1.0158 18524 1.0002 3560 1.0045 11136 1.0168 18713 1.0003 3749 1.0030 11326 1.0153 18903 1.0002 3938 1.0018 11515 1.0132 19092 1.0002 4128 1.0009 11705 1.0119 19282 1.0002 4317 1.0003 11894 1.0106 19471 1.0002 4507 1.0000 12084 1.0095 19660 1.0002 4696 1.0000 12273 1.0084 19850 1.0001 4886 1.0000 12462 1.0075 5075 1.0000 12652 1.0065 5264 1.0000 12841 1.0057 5454 1.0000 13031 1.0057 5643 1.0000 13220 1.0049 5833 1.0000 13410 1.0041 6022 1.0000 13599 1.0034 6211 1.0000 13788 1.0026 6401 1.0002 13978 1.0020 6590 1.0028 14167 1.0014 6780 1.0050 14357 1.0010 6969 1.0069 14546 1.0006 7159 1.0083 14735 1.0003 7348 1.0097 14925 1.0001 7537 1.0097 15114 1.0000
Unit 1 Cycle 19 WATTS BAR Revision 0 Table A.4 Rj Margin Decrease Factors for ROS 2
Cycle Burnup Rj Cycle Burnup Rj Cycle Burnup Rj (MWD/MTU) (MWD/MTU) (MWD/MTU) 150 1.0000 7727 1.0051 15304 1.0000 339 1.0000 7916 1.0067 15493 1.0000 529 1.0033 8106 1.0073 15683 1.0000 718 1.0084 8295 1.0065 15872 1.0000 908 1.0117 8485 1.0057 16061 1.0000 1097 1.0126 8674 1.0052 16251 1.0000 1287 1.0123 8863 1.0042 16440 1.0000 1476 1.0129 9053 1.0033 16630 1.0000 1665 1.0122 9242 1.0025 16819 1.0000 1855 1.0113 9432 1.0018 17009 1.0000 2044 1.0111 9621 1.0013 17198 1.0000 2234 1.0102 9811 1.0009 17387 1.0000 2423 1.0089 10000 1.0006 17577 1.0000 2612 1.0075 10189 1.0000 17766 1.0000 2802 1.0064 10379 1.0012 17956 1.0001 2991 1.0058 10568 1.0027 18145 1.0006 3181 1.0062 10758 1.0043 18334 1.0012 3370 1.0055 10947 1.0059 18524 1.0019 3560 1.0045 11136 1.0074 18713 1.0021 3749 1.0031 11326 1.0089 18903 1.0021 3938 1.0019 11515 1.0088 19092 1.0021 4128 1.0010 11705 1.0071 19282 1.0020 4317 1.0003 11894 1.0060 19471 1.0018 4507 1.0000 12084 1.0051 19660 1.0016 4696 1.0000 12273 1.0043 19850 1.0014 4886 1.0000 12462 1.0036 5075 1.0000 12652 1.0029 5264 1.0000 12841 1.0024 5454 1.0000 13031 1.0032 5643 1.0000 13220 1.0029 5833 1.0000 13410 1.0025 6022 1.0000 13599 1.0021 6211 1.0000 13788 1.0017 6401 1.0000 13978 1.0014 6590 1.0000 14167 1.0011 6780 1.0000 14357 1.0008 6969 1.0000 14546 1.0006 7159 1.0000 14735 1.0004 7348 1.0009 14925 1.0002 7537 1.0030 15114 1.0001
Unit 1 Cycle 19 WATTS BAR Revision 0 Table A.5 Required THERMAL POWER Limits and AFD Reductions
RAOC Required FQW(Z) Margin Required THERMAL Required AFD Operating Improvement (%) POWER Limit Reduction Space (%RTP)
ROS 1 5.5 90 See Figure 3 RA-1
>5.5 <50 N/A
ROS 2 6.3 90 See Figure 3 RA-2
>6.3 <50 N/A
Unit 1 Cycle 19 WATTS BAR Revision 0