m NRC MONTHLY OPERATING REPORT

SUMMARY

OF OPERATIONS WATERFORD 3 OCTOBER 1986 The unit started the month at approximately 100% power. On October 16 a unit power reduction was initiated to perform control element assembly exerc: ting and turbine valve testing required by technical specifications. On Octooer 19 the unit returned to 100% power. On October 20 at 2049, at 100% power, a reactor trip occurred on low DNBR due to dropping control element assembly

  1. 21. On October 23 at 0848, the generator was back on line and on October 25 the unit returned to 100% power. The unit continued operation at approximately 100% power to the end of the month.

8611180018 861031 ADOCK0500g2 DR 1

. = -.

I l

PRESSURIZER SAFETY VALVE FAILURES AND CHALLENGES WATERFORD 3 i

During the month of October 1986, there were no pressurizer safety valve failures t

or challenges.

I t

4

]

I 3

t I

I i

4 i

i 4

i l

. _ _ _. _ _ _ _.,.. ~. _ _ - _ - - _... _ _ _ _..... _. -. _.. - _,.... _....... _, _ _.

OPERATING DATA REPORT

~

UNIT NAME: WATERFORD 3 CITY / STATE: KILLONA/LA DATE: NOVEMBER 1986 OPERATING STATUS

1. Docket: 50-382 Notes
2. Reporting Period: OCTOBER 1986
3. Utility

Contact:

GEORGE MILLER Phone Number:

(504) 467-8211

4. Licensed Thermal Power (MWt): 3390
5. Nameplate Rating (Gross Mwe): 1153
6. Design Electrical Rating (Net MW'e): 1104
7. Maximum Dependable Capacity (Gross MWe): 1120 4
8. Maximum Dependable Capacity (Net MWe): 1075
9. If Changes Occur in Capacity Ratings (Items Number 4 Through 8) Since Last Report, Give Reasons:

10.

Power Level To Which Restricted, if Any (Net MWe):

NONE 11.

Reasons For Restrictions, If Any: N/A This Month Yr.-to-Date Cumulative 12.

Hours In Reporting Period 745.0 7296.0 9673.0 13.

Number Of Hours Reactor Was Critical 710.9 6388.6 8257.3 14.

Reactor Reserve Shutdown Hours 15 Hours Generator On-Line 685.0 6296.6 8103.6 16.

Unit Reserve Shutdown Hours ;

l

s OPERATING DATA REPORT (Continued)

This Month Yr.-to-Date Cumulative 17.

Gross Thermal Energy 2,206,239 20,711,895 26,354,334 Generated (MWH) 18.

Gross Electrical Energy 748,370 6,988,920 8,886,770 Generated (MWH) 19.

Net Electrical Energy 711,675 6,659,415 8,456,579 Generated (MWH) 20.

Unit Service Factor 91.9 86.3 83.8 21.

Unit Availability Factor 91.9 86.3 83.8 22.

Unit Capacity Factor 88.9 84.9 81.3 (Using MDC Net) 23.

Unit Capacity Factor 86.5 82.7 79.2 (Using DER Net) 24.

Unit Forced Outage Rate 8.1 3.4 8.9 25.

Unit Forced Outage Hours 60.0 222.4 787.2 26.

Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

Refueling / Maintenance Outage, November 1986

.Tanuary 1987, 8 weeks.

27.

If Shut Down At End of Report Period, Estimated Date Of Startup:

28.

Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY 3/4/85 INITIAL ELECTRICITY 3/18/85 COMMERCIAL OPERATION 9/24/85

~

I AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-382 UNIT WATERFORD 3 DATE NOVEMBER 1986 COMPLETED DY GEORGE MILLER TELEPHONE 504-467-8211 MONTH OCTOBER 1986 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 1103 17 931 2

1101 18 716 3

1103 19 1061 i

4 1102 20 946 5

1109 21

-46 6

1103 22

-46 7

1104 23 99 8

1106 24 670 9

1106 25 1071 10 1106 26 1072 11 1105 27 1079 12 1105 28 1098 13 1103 29 1100 14 1104 30 1097 15 1107 31 1095 16 1105 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

l l-UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT FOR OCTOBER 1986 DOCKET NO 50-382 UNIT NAME WATERFORD 3 DATE NOVEMBER 1986 COMPLETED BY GEORGE MILLER TELEPHONE 504-467-8211 Method of Licensee Cause & Corrective Duration Shutting Event System Component Action to No.

Date Type (HOURS)

REASON 2 Down Reactor 3 l

Report #

Code 4 Codes Prevent Recurrence

]

86-15 861016 S

0 B

5 N/A AA,TA ZZZZ Unit power reduction i

to perform control i

element assembly exercising and tur-bine valve testing j

required by tech-nical specifications.

4 I

86-16 861020 F

60.0 A

3 86-023 AA XCO At 100% power, a 3

l reactor trip occurred on low DNBR due to dropping control element assembly #21.

i 1

1 2

3 F: Forced Reason:

Method S: Scheduled A-Equipment Failure (Explain) 1-Manual B-Maintenance or Test 2-Manual Scram.

C-Refueling 3-Automatic Scram.

D-Regulatory Restriction 4-Continuation 4

l E-Operator Training &

5-Load Reduction IEEE Std. 805-1984 License Examination 9-Other 5

F-Administrative IEEE Std. 803A-1983 l

G-Operational Error (Explain) l H-Other (Explain) i

LoulSI ANA / 317 BARONNESTREET

+

P. O. BJX 60340 POWER & L1GHT NEW ORLEANS, LOUISIANA 70160 (504)595-3100

$LONdvsM November 13, 1986 W3P86-2807 A4.05 QA Mr. Ronald M. Scroggins Controller and Director Office of Resource Management U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 MONTHLY OPERATING REPORT

Dear Mr. Scroggins:

Enclosed is the subject monthly report which covers the operating statistics for the month of October 1986. This report is submitted per Section 6.9.1.6 of the Waterford 3 Technical Specifications for Facility Operating License No. NPF-38.

Very truly yours, O-K.W. Cook Nuclear Support & Licensing Manager KWC:GEW:ssf Enclosure cc:

R.D. Martin, NRC Region IV NRC, Director, Office of I&E G.W. Knighton, NRC-NRR NRC Resident Inspectors Office INPO Records Center (J.T. Wheelock)

B.W. Churchill J

W.M. Stevenson l \\

"AN EQUAL OPPORTUNITY EMPLOYER"

{