W3P85-1298, Forwards Rev 0 to 10-Yr Inservice Insp Program,Waterford Steam Electric Station Unit 3. Approval of Program & Relief from Testing Requirements of ASME Code Section XI Requested

From kanterella
(Redirected from W3P85-1298)
Jump to navigation Jump to search
Forwards Rev 0 to 10-Yr Inservice Insp Program,Waterford Steam Electric Station Unit 3. Approval of Program & Relief from Testing Requirements of ASME Code Section XI Requested
ML20128N764
Person / Time
Site: Waterford Entergy icon.png
Issue date: 05/28/1985
From: Cook K
LOUISIANA POWER & LIGHT CO.
To: Knighton G
Office of Nuclear Reactor Regulation
Shared Package
ML20128N767 List:
References
W3P85-1298, NUDOCS 8506030380
Download: ML20128N764 (1)


Text

Louisiama / ,4.c.-o~o.-.1 . o.ex.co.

P O W E R & L 1 G H T / N W 08%.ANS LeutStANA 70174-6008 G (504)3SS-2345 NIES Y May 28, 1985 W3P85-1298 A4.05 Mr. G._W. Knighton, Chief Licensing Branch No. 3 Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Mr. Knighton:

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 TEN YEAR INSERVICE INSPECTION PROGRAM, REVISION 0

Reference:

License Condition 2.C.5 In accordance with 10CFR50.55a(g), " Inservice Inspection Requirements"and License Condition 2.C.5, Louisiana Power & Light Company hereby submits seven (7) copies of the Ten Year Inservice Inspection Program which is prepared in accordance with the ASME Code Section XI, 1980 Edition with Addenda through Winter 1981. Relief from the testing requirements of Section XI is requested when full compliance with the requirements of the code is not practical. In such cases, specific information is provided which identifies the applicable code requirements, justification for the relief request, and the testing method to be used as an alternative.

It is hereby requested that the subject Program be approved and the ASME Section XI code relief requested be granted pursuant to Section 50.55a(g)(6)(i) of 10CFR50.

Very truly yours,

/

K.W. Cook Nuclear Support & Licensing Manager KWC:BGM:sms Enclosure 8506030380 850528 PDR ADOCK 05000382 IN 3 PDR Attachment cc (w/o enclosure): E.L. Blake, W.M. Stevenson, R.D. Martin, D.M. Crutchfield, J.H. Wilson, NRC Resident Inspectors Office