Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to Rev. 0 W3F1-2013-0024 Page 1 of 210 Page 592 ofl1014 Attachment D Area Walk-by Checklists (AWCs)

REVISION 0 See Attachment L for Revision 1 AWCs

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 593 of1014 Page 2 of 210 Sheet I of 4 Status: YN NE] UJ-]

Area Walk-By Checklist (AWC) AWC-001_

Location: Bldg. RAB Floor El. -35 Room, Area' Safe-guards B Room SWEL Components: SWEA-012Fo. 036 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE- NO UEl N/A[D potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
  • Anchor bolt on SISR-883 missing (1 of 4). See LB-01 in Attachment F.
2. Does anchorage of equipment in the area appear to be free of YZ NE-] u[-] N/A--

significant degraded conditions?

0 All anchorage is free of significantly degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit YN NE]I UE N/AE]

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 594 of'1014 Page 3 of 210 Sheet 2 of 4 Status: YZ ND] UD-I Area Walk-By Checklist (AWC) AWC-001 Location: Bldg. RAB Floor El. -35 Room, Area Safequar ds B Room

4. Does it appear that the area is free of potentially adverse seismic YZ NEI U-I N/ADI spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YZ NDI UD- N/ADI interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic Y[ NDI UD- N/AD-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YN ND:- U[D- N/AD-interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 595 of1014 Page 4of 210 Sheet 3 of 4 Status: Y[<i Nil U--

Area Walk-By Checklist (AWC) AWC-001 Location: Bldg. RAB Floor El. -35 Room, Area Safecquards B Room

8. Have you looked for and found no other seismic conditions that could YO Nn UnII adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Dinesh Patel Date: 10-02-2012 Natalie George 10-02-2012

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 596 ofl 014 Page 5 of 210 Sheet 4 of 4 Status: Y; NF] UI-Area Walk-By Checklist (AWC) AWC-001 Location: Bldg. RAB Floor El. -35 Room, Area Safeaiuards B Room SWEL Components: SWELI-012, 036 Note: Anchor bolt on SISR-883 missing (1 of 4)

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 597 of'1014 Page 6 of 210 Sheet I of 4 Status: YZ NM UI-Area Walk-By Checklist (AWC) AWC-002 Location: Bldg. RAB Floor El. -35 Room, Area, Safeguards Room A SWEL Components: SWELI-013, 051 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NI- U[-- N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YN NO U-- N/AD-significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YER NEI UD- N/AD--

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 598 of1014 Page 7of 210 Sheet 2 of 4 Status: YCR NE-I UI*

Area Walk-By Checklist (AWC) AWC-002 Location: Bldg. RAB Floor El. -35 Room, Area Safeguards Room A

4. Does it appear that the area is free of potentially adverse seismic YO NOh UE N/AE spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Y[ NEI U-I N/A[:

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Y[ NDI U[] N/A[I interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[D ND UE- N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

. Tubes lying around due to ongoing work; no seismic concern

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1`-2013-0024 Rev. 0 Page 599 of1014 Page 8 of 210 Sheet 3 of 4 Status: YZ NiO UD Area Walk-By Checklist (AWC) AWC-002 Location: Bldg. RAB Floor El. -35 Room, Area Safeguards Room A

8. Have you looked for and found no other seismic conditions that could YE NEI UFL adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Mild surface corrosion on base plate located by exit, no seismic concern; CR-WF3-2012-05285 and WR 287666 initiated to address corrosion Evaluated by: Dinesh Patel Date: 10/3/12 Brian Pace 10/3/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 600 ofiO14 Page 9 of 210 Sheet 4 of 4 Status: Y] N-- U-I!

Area Walk-By Checklist (AWC) AWC-002_

Location: Bldg. RAB Floor El. -35 Room, Area Safeguards Room A SWEL Components: SWELI-013. 051 Photographs Note: Mild surface corrosion on base plate located Note:

by exit

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 601 of1014 Page 10of 210 Sheet I of 5 Status: YN N-- UD-Area Walk-By Checklist (AWC) AWC-003 Location: Bldg. RAB Floor El. -35 Room, AreaI Room B17 SWEL Components: SWELl -023. 030 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YO NDI UD- N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YZ NDI UD- N/AD significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YZ NDI UD- N/AD-raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 602 of1014 Page 11 of 210 Sheet 2 of 5 Status: Y[* ND-- uD-Area Walk-By Checklist (AWC) AWC-003 Location: Bldg. RAB Floor El. -35 Room, Area Room B17

4. Does it appear that the area is free of potentially adverse seismic YO ND_ U[i N/ArI spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YZ ND-] UD1 N/A[D]

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic YZ NDJ UD0 N/ADI interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YZ N[D U[-D N/A[D]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F11-2013-0024 Rev. 0 Page 603 of1014 Page 12 of 210 Sheet 3 of 5 Status: YZ NE] UD--

Area Walk-By Checklist (AWC) AWC-003 Location: Bldg. RAB Floor El. -35 Room, Area Room B17

8. Have you looked for and found no other seismic conditions that could YZ NEI UF adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

" Bolt missing (1 of 6) near RAB sump pump SP EMTR213A AK, no seismic concern; WR 288319 initiated to address missing bolt

  • One eye lift missing from cover near RAB sump pump SP EMTR213A AK; no seismic concern Evaluated by: Natalie George Date: 10/8/12 Chu-Chieh Lin 10/8/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 604 ofO114 Page 13 of 210 Sheet 4 of 5 Status: Y* N[-- ULI-I (AWC) AWC-003 Area Walk-By Checklist Location: Bldg. RAB Floor El. -35 Room, Area Room B17 SWEL Components: SWELl-023, 030 Photographs Note: Bolt missing (1 of 6) near RAB sump pump SP EMTR213A AK

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3FI-201 3-0024 Rev. 0 Page 605 of1014 Page 14of 210 Sheet 5 of 5 Status: Y ] N-- U--

Area Walk-By Checklist (AWC) AWC-003_

Location: Bldg. RAB Floor El. -35 Room, Area Room B17 SWEL Components: SWEL1 -023. 030 Note: Fluorescent lights do not have cages.

Falling bulbs will not damage equipment and is not a seismic concern.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 606 of1014 Page 15of 210 Sheet 1 of 4 Status: Y" ND-- U--

Area Walk-By Checklist (AWC) AWC-004 Location: Bldg. RAB Floor El. -35 Room, Area' Room B20 SWEL Components: SWEL1 -056, 066 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE NEI] U- N/AZ-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YE NEI uL- N/A--

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YN NE-I U[] N/A[-]

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 607 ofI1014 Page 16of 210 Sheet 2 of 4 Status: Y[ NjI UL-I Area Walk-By Checklist (AWC) AWC-004 Location: Bldg. RAB Floor El. -35 Room, Area Room B20

4. Does it appear that the area is free of potentially adverse seismic YZ NEIl U[I- N/A[:]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5. Does it appear that the area is free of potentially adverse seismic Y] NEI UJ- N/A-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YjN NO UI- N/AD:]

interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic YZ N- U[-D N/AD-]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 608 of1014 Page 17of 210 Sheet 3 of 4 Status: YM NI I U--

Area Walk-By Checklist (AWC) AWC-004 Location: Bldg. RAB Floor El. -35 Room, Area Room B20

8. Have you looked for and found no other seismic conditions that could YZ NDIUn adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Ceiling lights swing; no seismic concern as lights are well anchored and will not interact with other equipment Evaluated by: Dinesh Patel Date: 10/2/12 Natalie Georqe 10/2/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 609 of1014 Page 18 of 210 Sheet 4 of 4 Status: YZ NE] UF1 Area Walk-By Checklist (AWC) AWC-004 Location: Bldg. RAB Floor El. -35 Room, Area Room B20 SWEL Components: SWEL1 -056, 066 Photographs Note: Area

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 610 of1O14 Page 19of 210 Sheet I of 5 Status: YMI N-- U-il Area Walk-By Checklist (AWC) AWC-005_

Location: Bldg. RAB Floor El. -35 Room, Area, Boric Acid Makeup Tank A Room SWEL Components: SWELI -016. 040, 089 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YO N-- ULI-- N/A--

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of YZ NEI UL] N/AL]

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YN Nr-I ULI N/AE1 raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 611 oflO14 Page 20 of 210 Sheet 2 of 5 Status: Y[O ND- UD-Area Walk-By Checklist (AWC) AWC-005 Location: Bldg. RAB Floor El. -35 Room, Area Boric Acid Makeup Tank A Room

4. Does it appear that the area is free of potentially adverse seismic YV ND UD-- N/ADI spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YN NDI UDI N/ADý interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YZ NDI UD N/AD interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[Z NDI UD- N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 612 of1014 Page 21 of 210 Sheet 3 of 5 Status: Y,2 NE] U-I Area Walk-By Checklist (AWC) AWC-005 Location: Bldg. RAB Floor El. -35 Room, Area Boric Acid Makeup Tank A Room

8. Have you looked for and found no other seismic conditions that could YM NO] UI-adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Housekeeping issues include loose rope from above and from a ladder; no seismic concern
  • Boric acid deposits on yoke bolt (bottom) of valve 131A, no seismic concern; CR-WF3-201 1-00024 and WR 224286 previously initiated for this condition
  • Active oil leak under Boric Acid Makeup Pump; towel dated 8-28-2012 to track amount of leakage; no seismic concern
  • Bolts and steel corroded on supports on line connected to valve 11 3A, no seismic concern; CR-WF3-2012-05296 and WR 287685 and 287687 initiated to address corrosion
  • Missing bolt (1 of 10) on B3424-NA, no seismic concern; CR-WF3-2012-05296 and WR 287689 initiated to address missing bolt Evaluated by: Dinesh Patel Date: 10/3/12 Natalie Georqe 10/3/12

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 613 of1014 Page 22 of 210 Sheet 4 of 5 Status: YZ ND- U-'

Area Walk-By Checklist (AWC) AWC-005 Location: Bldg. RAB Floor El. -35 Room, Area Boric Acid Makeup Tank A Room SWEL Components: SWELl -016. 040. 089 Photographs Note: Housekeeping issues include loose rope Note: Boric acid deposits on yoke bolt (bottom) of from above and from a ladder; trip hazard valve 131A

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 614 of1014 Page 23 of 210 Sheet 5 of 5 Status: YN N7I" U7]

Area Walk-By Checklist (AWC) AWC-005_

Location: Bldg. RAB Floor El. -35 Room, Area Boric Acid Makeup Tank A Room SWEL Components: SWEILl -016. 040, 089 Note: Active oil leak under Boric Acid Makeup Note: Bolts and steel corroded on supports on line Pump; towel dated 8-28-2012 to track amount of connected to valve 11 3A leakage Note: Missing bolt (1 of 10) on B3424-NA

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 615 of1014 Page 24 of 210 Sheet 1 of 4 Status: YI* ND UD--

(AWC) AWC-006 Area Walk-By Checklist Location: Bldg. RAB Floor El. -35 Room, Area' Shutdown Cooling Heat Exchanger A Room SWEL Components: SWELl-092 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Y[ NDI UD- N/ADJ potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YE NDI U-- N/AD-significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YE NDJ U[- N/ADl raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 616 of1014 Page 25 of 210 Sheet 2 of 4 Status: YZ NFI Ui-Area Walk-By Checklist (AWC) AWC-006 Location: Bldg. RAB Floor El. -35 Room, Area Shutdown Cooling Heat Exchanger A Room

4. Does it appear that the area is free of potentially adverse seismic YN N[i UI:] N/A-]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5. Does it appear that the area is free of potentially adverse seismic Y[ ND: U-1 N/AD--

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Y[ ND:] U-] N/AD-1 interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YO NEI U-- N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3FI-2013-0024 Rev. 0 Page 617 ofl 014 Page 26 of 210 Sheet 3 of 4 Status: Y; NF-- UM Area Walk-By Checklist (AWC) AWC-006 Location: Bldg. RAB Floor El. -35 Room, Area Shutdown Cooling Heat Exchanger A Room.

8. Have you looked for and found no other seismic conditions that could YZ No UF adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

. 2 hoses hanging from above to floor drain; no seismic concern Evaluated by: Dinesh Patel Date: 10/3/12 Natalie George 10/3/12

Engineering Report No, WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 618 of 1014 Page 27 of 210 Sheet 4 of 4 Status: YO NEI UF]

Area Walk-By Checklist (AWC) AWC-006 Location: Bldg. RAB Floor El. -35 Room, Area Shutdown Cooling Heat Exchanger A Room SWEL Components: SWELl -092 Photographs Note: 2 hoses hanging from above to floor drain

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 619 of1014 Page 28 of 210 Sheet I of 4 Status: YN NEI UM Area Walk-By Checklist (AWC) AWC-007 Location: Bldg. RAB Floor El. -35 Room, Area' Emergency Feedwater Pump (Turbine Driven) Area SWEL Components: SWELl -010 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NEI] UE] N/A-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YN N[D UD N/AZ-significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit Y[ N[] U[I N/A[--

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 620 of1014 Page 29 of 210 Sheet 2 of 4 Status: YE ND-- U-I Area Walk-By Checklist (AWC) AWC-007 Location: Bldg. RAB Floor El. -35 Room, Area Emergency Feedwater Pump (Turbine Driven) Area

4. Does it appear that the area is free of potentially adverse seismic YN NE] UiD N/A-]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic Y[ N[D UD1 N/AD-]

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic YjZ NI LiD N/A[D-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[-- NZ U[i1 N/A-1 interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
  • One contamination protection disposal bin not secured to others. See LB-02 in Attachment F.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1`-2013-0024 Rev. 0 Page 621 ofO114 Page 30 of 210 Sheet 3 of 4 Status: YE NO- U-Area Walk-By Checklist (AWC) AWC-007 Location: Bldg. RAB Floor El. -35 Room, Area Emergency Feedwater Pump (Turbine Driven) Area

8. Have you looked for and found no other seismic conditions that could Y< NEI UI-adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Dinesh Patel Date: 10/2/12 Natalie Georqe 10/2/12

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 622 of 1014 Page 31 of 210 Sheet 4 of 4 Status: YN NEI UlI Area Walk-By Checklist (AWC) AWC-007 Location: Bldg. RAB Floor El. -35 Room, Area Emeraency Feedwater Pump (Turbine Driven) Area SWEL Components: SWELl - 010 Photographs Note: Fluorescent lights do not have cages. Falling Note: Bin not secured to others bulbs will not damage equipment and is not a seismic concern.

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 623 of1014 Page 32 of 210 Sheet 1 of 5 Status: YZ N--1 U-Area Walk-By Checklist (AWC) AWC-008_

Location: Bldg. CTB Floor El. -35 Room, Area, Room 59A. Transformer Room SWEL Components: SWELl -008 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN ND UI-] N/AD potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YZ NDI UD_ N/AD significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YN NDI UD-] N/AD-raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 624 of1014 Page 33 of 210 Sheet 2 of 5 Status: YN N-- UI-Area Walk-By Checklist (AWC) AWC-008 Location: Bldg. CTB Floor El. -35 Room, Area Room 59A, Transformer Room

4. Does it appear that the area is free of potentially adverse seismic YE N: UI-I N/AI-I spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Y[ NEI UI N/ADl interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YZ NEI UI- N/AD-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YZ NEI U[-- N/A[I interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 625 ofO114 Page 34 of 210 Sheet 3 of 5 Status: YO NJ- UF]

Area Walk-By Checklist (AWC) AWC-008 Location: Bldg. CTB Floor El. -35 Room, Area Room 59A. Transformer Room

8. Have you looked for and found no other seismic conditions that could YE NEI UE-adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

" Mild corrosion on supports and structural steel, no seismic concern; CR-WF3-2012-04955 and WR 286027 initiated to address corrosion

  • Spalled concrete above Fan 2-SB; no seismic concern
  • Exposed insulation on structural member near Fan 2-SB; no seismic concern Evaluated by: Brian Pace Date: 10-15-2012 Dinesh Patel 10-15-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 626 ofl 014 Page 35 of 210 Sheet 4 of 5 Status: YN NFj U-ID Area Walk-By Checklist (AWC) AWC-008 Location: Bldg. CTB Floor El. -35 Room, Area Room 59A, Transformer Room SWEL Components: SWEnLg- 008 Photographs corrosion of structural steel. Note: M corrosion on cooling tower fan housing.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 627 ofl 014 Page 36 of 210 Sheet 5 of 5 Status: YN NIZI U-I Area Walk-By Checklist (AWC) AWC-008 Location: Bldg. CTB Floor El. -35 Room, Area Room 59A. Transformer Room SWEL Components: SWELl-008 Note: Spalled concrete; no seismic concern. onUce; r. 1 ýmic concern.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 628 of1014 Page 37 of 210 Sheet I of 5 Status: YZ NDl UI--

Area Walk-By Checklist (AWC) AWC-009 Location: Bldg. CTB Floor El. -35 Room, Area, B59A, Wet Cooling Tower B Area SWEL Components: SWELl-024 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YD NM UID N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
  • Anchor bolt missing on pipe support. See LB-03 in Attachment F.
2. Does anchorage of equipment in the area appear to be free of YN ND UD] N/ADl significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YN NDJ uD N/ADl raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 629 oflO14 Page 38 of 210 Sheet 2 of 5 Status: Y[ NEI U-Area Walk-By Checklist (AWC) AWC-009 Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Area

4. Does it appear that the area is free of potentially adverse seismic Y[ NoI UI] N/A[-]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5. Does it appear that the area is free of potentially adverse seismic YZ NEI UI- N/AD-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic Y[ NEI UD1 N/AD-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YZ ND:] UF- N/AD--

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 630 of'1014 Page 39 of 210 Sheet 3 of 5 Status: YN NI U-Area Walk-By Checklist (AWC) AWC-009 Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Coolinci Tower B Area

8. Have you looked for and found no other seismic conditions that could YZ NE] Uil adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

" Safety light cover and bulb broken, no seismic concern; CR-WF3-2012-04960 initiated to address light cover and bulb

.1 .. "

Evaluated by: Dinesh Patel Date: 10/1/12 Brian Pace 10/1/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 631 of1014 Page 40 of 210 Sheet 4 of 5 Status: Yr7 NIl ULI Area Walk-By Checklist (AWC) AWC-009 Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Area SWEL Components: SWELl-024 Photographs Note: Corrosion on conduit supports Note: Missing one bolt from the plate, moderate corrosion on the box

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 632 oflO14 Page 41 of 210 Sheet 5 of 5 Status: YZ NEI UD--

Area Walk-By Checklist (AWC) AWC-009 Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Area SWEL Components: SWELl-024 Note: Safety light cover and bulb broken Note: Valve diaphragm is severely corroded

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 633 of1014 Page 42 of 210 Sheet I of 4 Status: YN NE] UL]

Area Walk-By Checklist (AWC) AWC-010 Location: Bldg. CTA Floor El. -35 Room, Area, WET COOLING TOWER A AREA SWEL Components: SWELl-060 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Y[ ND U[-- N/AL]

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

0 All anchorage is free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of YZ NEO ULi N/AL]

significant degraded conditions?

0 No corrosion found on equipment anchorage.

3. Based on a visual inspection from the floor, do the cable/conduit YN N[l ULI N/Al--

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 634 of"1014 Page 43 of 210 Sheet 2 of 4 Status: YE N[I- Ui-Area Walk-By Checklist (AWC) AWC-010 Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

4. Does it appear that the area is free of potentially adverse seismic YE N[] U- N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Y[ ND-- UDI N/AD-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YN ND UD- N/AD interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YIZ NDI UD- N/ADI interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 635 oflO14 Page 44 of 210 Sheet 3 of 4 Status: Y; NF] UF Area Walk-By Checklist (AWC) AWC-010 Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

8. Have you looked for and found no other seismic conditions that could YE N[ EU adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Bolts on grounding cable supports on the wall under fan housing shows moderate to severe corrosion; no seismic concern; WR-289630 initiated for this condition Evaluated by: Brian Pace Date: 10/5/12 Dinesh Patel 10/5/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 636 of1014 Page 45 of 210 Sheet 4 of 4 Status: YN NEI U[-I Area Walk-By Checklist (AWC) AWC-010 Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA SWEL Components: SWELl-060 Photographs Note: Bolts on grounding cable supports on the Note:

wall under fan housing shows moderate to severe corrosion

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 637 of1014 Page 46 of 210 Sheet I of 5 Status: Y[] NL-- ULI-Area Walk-By Checklist (AWC) AWC-011_

Location: Bldg. CTB Floor El. -35 Room, Area, B60A. WET COOLING TOWER B AREA SWEL Components: SWELl-020 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NEI UD1 N/AED potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YN NDI UD- N/AD-significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YLI NE; UI- N/ADI raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
  • Severe corrosion of tube steel supporting conduits
  • Conduit 30819D-SB corrosion Corroded struts supporting large bore pipes (below and above) 0 Corroded angle steel member supporting overhead stairs I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 638 of1014 Page 47 of 210 Sheet 2 of 5 Status: YO ND UD--

Area Walk-By Checklist (AWC) AWC-011_

Location: Bldg. CTB Floor El. -35 Room, Area B60A, WET COOLING TOWER B AREA

4. Does it appear that the area is free of potentially adverse seismic Y[ NDI UE] N/AD1 spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

. Minor corrosion of steel plate, no seismic concern

5. Does it appear that the area is free of potentially adverse seismic Y[ NDI UD- N/AD1 interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YZ NDI UD1 N/AD-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YZ N[D] U[D] N/A[D]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 639 oflO14 Page 48 of 210 Sheet 3 of 5 Status: YE NrIl U[--

Area Walk-By Checklist (AWC) AWC-011I Location: Bldg. CTB Floor El. -35 Room, Area B60A, WET COOLING TOWER B AREA

8. Have you looked for and found no other seismic conditions that could YN N[-] UJ-adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary) 0 CR-WF3-2012-05729 initiated to address corrosion conditions documented in this AWC.

Evaluated by: Dinesh Patel Date: 10-01-2012 Chu-Chieh Lin - ... - 10-01-2012

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 640 ofl1014 Page 49 of 210 Sheet 4 of 5 Status: YN NEI[ U[I Area Walk-By Checklist (AWC) AWC-011_

Location: Bldg. CTB Floor El. -35 Room, Area B60A, WET COOLING TOWER B AREA SWEL Components: SWELl-020 Photographs

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 641 ofO114 Page 50 of 210 Sheet 5 of 5 Status: YN NDI U['-D Area Walk-By Checklist (AWC) AWC-01 1 Location: Bldg. CTB Floor El. -35 Room, Area B60A, WET COOLING TOWER B AREA SWEL Components: SWELl-020 ILt:'. %.oUfI UbIUI I UI I U IU bUPPUI L bLUU wLalkw Ot t: u PpFuIL U1 LIit:

walkway Note: Severe corrosion on the horizontal Note: Conduit 30819D-SB corrosion connector

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 642 of1014 Page 51 of 210 Sheet 1 of 5 Status: Y; NFI U[D]

Area Walk-By Checklist (AWC) AWC-013 Location: Bldg. CTA Floor El. -35 Room, Area, WET COOLING TOWER A AREA SWEL Components: SWELl-015 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NI:] U[J N/ADJ potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YZ NDI UD- N/AD-significant degraded conditions?
  • Bolts on nearby pipe support are mildly corroded (near SE wall); no seismic concern
3. Based on a visual inspection from the floor, do the cable/conduit Y[ ND uID N/AD-raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
  • Condulet underneath junction box B3CCF284A-SA is mildly corroded; no seismic concern If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 643 of1014 Page 52 of 210 Sheet 2 of 5 Status: YN ND- U-I Area Walk-By Checklist (AWC) AWC-013 Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

4. Does it appear that the area is free of potentially adverse seismic YZ N[:] U-- N/Afl spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Steel member overhead has mild surface corrosion on both ends; no seismic concern
5. Does it appear that the area is free of potentially adverse seismic YO N[l UI- N/A[-]

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic YZ NDI UD-- N/AD-]

interactions that could cause a fire in the area?

7. Does it appear that the area' is free of potentially adverse seismic YI ND-- U-I N/A[D interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 644 of`1014 Page 53 of 210 Sheet 3 of 5 Status: YM N-i UF[

Area Walk-By Checklist (AWC) AWC-013 Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

8. Have you looked for and found no other seismic conditions that could YN N[- rIU adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Electrical junction box B30613-NAB cover has three bolts missing (3 of 8), no seismic concern; CR-WF3-2012-05301 and WR 287695 initiated to address missing bolts Evaluated by: Brian Pace Date: 10/5/12 Dinesh Patel 10/5/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 645 of1014 Page 54 of 210 Sheet 4 of 5 Status: YZ NFI UD-Area Walk-By Checklist (AWC) AWC-013 Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA SWEL Components: SWELlR-015 Photooraohs Note: Bolts on nearby pipe support are mildly Note: Condulet underneath junction box corroded B3CCF284A-SA is mildly corroded

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 646 of1014 Page 55 of 210 Sheet 5 of 5 Status: YZ NEI ULI-Area Walk-By Checklist (AWC) AWC-013 Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA SWEL Components: SWELl -015 Note: Steel member overhead has mild corrosion Note: Bolts on the blind flange and flange on on both ends south east wall has mild corrosion Note: Electrical junction box B30618-NAB cover has three bolts missing (3 of 8)

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 647 of1014 Page 56 of 210 Sheet 1 of 6 Status: YE; NR UR--

Area Walk-By Checklist (AWC) AWC-014 Location: Bldg. RAB Floor El. -35 Room, Area, B59A, MCC AREA SWEL Components: SWELl-003 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YD- NO U[I N/AD potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
  • Missing bolt on support near valve SPMVAAA328
  • Bolts missing on pump base plate o See LB-04 in Attachment F.
2. Does anchorage of equipment in the area appear to be free of YD] NO UD- N/AD]

significant degraded conditions?

  • SPMVAAA327 severely corroded
  • Severe corrosion on base plate
  • Severe corrosion on pipe support
3. Based on a visual inspection from the floor, do the cable/conduit Y-I NO uD N/AFD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

. Conduit housing near valve SP MVAAA330 severely corroded

'If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item,

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 648 of1014 Page 57 of 210 Sheet 2 of 6 Status: YE NF UD Area Walk-By Checklist (AWC) AWC- 014 Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA

4. Does it appear that the area is free of potentially adverse seismic YZ NEI U- N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YZ NE uLIO N/A[-D interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YZ NO uID N/A[-D interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YN NEI Ur N/AD-interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 649 of1014 Page 58 of 210 Sheet 3 of 6 Status: YZ NE] UI--

Area Walk-By Checklist (AWC) AWC- 014 Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA

8. Have you looked for and found no other seismic conditions that could Y-I NE UI-adversely affect the safety functions of the equipment in the area?
  • Moderate corrosion on valve SP MVAAA326 B Comments (Additional pages may be added as necessary)
  • Mild corrosion on fan housing, no seismic concern

'

  • Mild corrosion on grate, pump base plate, base plate, etc., no seismic concern
  • Mild corrosion on supports throughout dry cooling tower area, no seismic concern
  • Insulation near valve SP MVAAA330 cracked; not a seismic concern
  • Moderate corrosion tornado/missile shielding structural steel

" CR-WF3-2012-04956 was initiated to address all corrosion issues as well as the missing bolt on the support near valve SPMVAAA328.

Evaluated by: Dinesh Patel Date: 10/01/2012 Chu-ChiehLin 10/01/2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 650 oflO14 Page 59 of 210 Sheet 4 of 6 Status: Y] NR- URL Area Walk-By Checklist (AWC) AWC- 014 Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA SWEL Components: SWELl- 003 Photographs

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 651 ofl 1014 Page 60 of 210 Sheet 5 of 6 Status: YZ N-I UI-Area Walk-By Checklist (AWC) AWC- 014 Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA SWEL Components: SWELl- 003 Note: Severe corrosion on base plate Note: Severe corrosion on pipe support Note: Moderate corrosion tomado/missile shielding structural steel

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 652 of1014 Page 61 of 210 Sheet 6 of 6 Status: YZJ N-] UFI-Area Walk-By Checklist (AWC) AWC- 014 Location: Bldg. RAB Floor El. -35 Room, Area B59A. MCC AREA SWEL Components: SWEILl- 003

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 653 of1014 Page 62 of 210 Sheet 1 of 5 Status: YI7 NE] U--

Area Walk-By Checklist (AWC) AWC-015 Location: Bldg. RAB Floor El. +7 Room, Area, HVAC EQUIPMENT ROOM SWEL Components: SWELI-039 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE N[l U-iD N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YE NDI UD- N/A[D]

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YE N[D UD- N/A--

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 654 of'1014 Page 63 of 210 Sheet 2 of 5 Status: YZ NEI ULII Area Walk-By Checklist (AWC) AWC-01 5 Location: Bldg. RAB Floor El. +7 Room, Area HVAC EQUIPMENT ROOM

4. Does it appear that the area is free of potentially adverse seismic Y[ NEI U- N/AZ spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages, but falling bulbs would have no impact on equipment. No seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YZ NO U[-] N/AZ interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic Y[ NEI U- N/AZ-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[ NE U- N/AF interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
  • Housekeeping issues include clothes hanger on top of unit, coins and paper on the ground, and white caution tape on top of conduit; no seismic concern

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F11-2013-0024 Rev. 0 Page 655 of1014 Page 64 of 210 Sheet 3 of 5 Status: YM NIj U-I Area Walk-By Checklist (AWC) AWC-015 Location: Bldg. RAB Floor El. +7 Room, Area HVAC EQUIPMENT ROOM

8. Have you looked for and found no other seismic conditions that could Y[K NE] UI-adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • CHW coil isolation valves CHWMVAAA231 and CHWMVAAA883 show leakage on top; no seismic concern

" SCH inlet isolation valves SCHMVAAA528 and SCHMVAAA553 show mild to moderate surface corrosion, no seismic concern; WR 287827 initiated to address corrosion Evaluated by: Dinesh Patel Date: 10/2/12 Brian Pace 10/2/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 656 of1O14 Page 65 of 210 Sheet 4 of 5 Status: YZ NE]I U-I Area Walk-By Checklist (AWC) AWC-015 Location: Bldg. RAB Floor El. +7 Room, Area HVAC EQUIPMENT ROOM SWEL Components: SWELl-039 Photographs Note: SCH inlet isolation valve SCHMVAAA553 Note: SCH inlet isolation valve SCHMVAAA528 shows mild to moderate surface corrosion shows mild to moderate surface corrosion I

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 657 ofl1014 Page 66 of 210 Sheet 5 of 5 Status: YN Nr-] UD-]

Area Walk-By Checklist (AWC) AWC-015 Location: Bldg. RAB Floor El. +7 Room, Area HVAC EQUIPMENT ROOM SWEL Components: SWELl-039 sLhows VsigVn of miRVldcoV*rOOn is leaking and I Note: Valve CHWMVAAA231 is leaking and shows signs of mild corrosion shows signs of mild corrosion Note: Caution tape left behind piping Note:

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 658 of'1014 Page 67 of 210 Sheet 1 of 5 Status: YE NiD U--

Area Walk-By Checklist (AWC) AWC-016_

Location: Bldg. RAB Floor El. +21 Room, Area' Switchpear A Room SWEL Components: SWELo-006. 071. 082. 087 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE N[I U-I N/AZ7 potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YE NEI- U[- N/A[Z-significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YM NDI U[-7 N/A[

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 659 of1014 Page 68 of 210 Sheet 2 of 5 Status: YI* NEil UD--

Area Walk-By Checklist (AWC) AWC-016 Location: Bldg. RAB Floor El. +21 Room, Area Switchqear A Room

4. Does it appear that the area is free of potentially adverse seismic YE NIh Ul-- N/A--

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic Y[J NEI U-1 N/AL-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YO N[! uE1 N/AL]

interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic YE NE[I U[- N/AF-interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 660 ofO114 Page 69 of 210 Sheet 3 of 5 Status: YN NEI UI-Area Walk-By Checklist (AWC) AWC-016 Location: Bldg. RAB Floor El. +21 Room, Area Switchpear A Room

8. Have you looked for and found no other seismic conditions that could Y[ N[] U-I adversely affect the safety functions of the equipment in the area?
  • Conduit is rigidly supported to equipment. This is acceptable per drawing B288, S19-1.

Comments (Additional pages may be added as necessary)

  • Phone cord is a trip hazard; no seismic concern
  • Bent and missing weld on studs; no seismic concern
  • Missing clip on dummy breaker storage, bent door; no seismic concern
  • Base plate on support has eight bolt holes but only four bolts. However, this is acceptable since all other similar supports have only four bolts; no seismic concern Evaluated by: Natalie George Date: 10/4/12 Chu-Chieh Lin 10/4/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 661 of1014 Page 70 of 210 Sheet 4 of 5 Status: YN NI uLI-I Area Walk-By Checklist (AWC) AWC-016 Location: Bldg. RAB Floor El. +21 Room, Area Switchpear A Room SWEL Components: SWELo-006. 071. 082. 087 PhotoaraDhs

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 662 of1O14 Page 71 of 210 Sheet 5 of 5 Status: YN NFI U7 Area Walk-By Checklist (AWC) AWC-016 Location: Bldg. RAB Floor El. +21 Room, Area Switchqear A Room SWEL Components: SWELl -006. 071. 082. 087 Note: Bent door on dummy breaker storage Note: Missing clip on dummy breaker storage Note: Base plate on support has eight bolt holes but only four bolts

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 663 of1014 Page 72 of 210 Sheet I of 4 Status: YN ND UD Area Walk-By Checklist (AWC) AWC-017 Location: Bldg. RAB Floor El. +21 Room, Area, Battery Room B SWEL Components: SWELl-070 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE NEI UD N/A[]

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of YZ NDI UD- N/AD]

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YZ NDI UD- N/A[D raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

1If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 664 of1014 Page 73 of 210 Sheet 2 of 4 Status: YZ ND1 UI-Area Walk-By Checklist (AWC) AWC-017 Location: Bldg. RAB Floor El. +21 Room, Area Battery Room B

4. Does it appear that the area is free of potentially adverse seismic Y[ ND UD- N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YE NDI uD-- N/AD interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YN ND UD N/ADý interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[ NDI uD N/ADý interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 665 of'1014 Page 74 of 210 Sheet 3 of 4 Status: YZ N-I ULI Area Walk-By Checklist (AWC) AWC-017 Location: Bldg. RAB Floor El. +21 Room, Area Battery Room B

8. Have you looked for and found no other seismic conditions that could Y[ No U[--

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10/2/12 Dinesh Patel 10/2/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 666 of1014 Page 75 of 210 Sheet 4 of 4 Status: YZ NO U-I Area Walk-By Checklist (AWC) AWC-017 Location: Bldg. RAB Floor El. +21 Room, Area Battery Room B SWEL Components: SWELl-070 Photographs Note: Battery racks and area Note:

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 667 of1014 Page 76 of 210 Sheet 1 of 4 Status: YZ NFJ U-Area Walk-By Checklist (AWC) AWC-018 Location: Bldg. RAB Floor El. +21 Room, Area, Switchqear Room B SWEL Components: SWELl -002. 007. 068. 069. 097 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NEI ULI N/ALl potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

9 Anchorage is in good condition of equipment in the area.

2. Does anchorage of equipment in the area appear to be free of Y[Z NEI UL- N/AL[

significant degraded conditions?

0 No corrosion found on any anchorage in the area.

3. Based on a visual inspection from the floor, do the cable/conduit YJZ NEI UL- N/AL1 raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
  • Conduit rigidly attached to equipment is acceptable per drawing no. B288 sh. 19-1

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 668 of'1014 Page 77 of 210 Sheet 2 of 4 Status: YI* NEI-- UI--

Area Walk-By Checklist (AWC) AWC-018 Location: Bldg. RAB Floor El. +21 Room, Area Switchqear Room B

4. Does it appear that the area is free of potentially adverse seismic Y[-] NZ U- N/A[-I spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

" Lighting is in walkways, posing no seismic concern.

  • A temporary housing has been installed in the Switchgear B Room. It has the potential to impact panels near it. The walls are bolted together, but there are no anchors bolting the enclosure to the floor. There is only a 7" clearance from LCP-62 and one side of the enclosure.

o This was resolved using CR-12-5172 and EC40448.

See photos. Enclosure was braced at the top and bottom to structural steel members to ensure rigidity of the enclosure.

5. Does it appear that the area is free of potentially adverse seismic Y[R NEI- U-E N/A[D-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YN NE] U-I N/AD]

interactions that could cause a fire in the area?

7, Does it appear that the area is free of potentially adverse seismic YN NEI UE N/AD-interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 669 of1014 Page 78 of 210 Sheet 3 of 4 Status: YM ND UI--

Area Walk-By Checklist (AWC) AWC-018 Location: Bldg. RAB Floor El. +21 Room, Area Switchgear Room B

8. Have you looked for and found no other seismic conditions that could YI N[Ij UM adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated byv Brian Pace Date: 10-16-2012 Chi -rhit-h Lin 10-16-2012 10-16-2012 Chij-Chieh Lin

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 670 of1014 Page 79 of 210 Sheet 4 of 4 Status: YZ NIli U--

Area Walk-By Checklist (AWC) AWC-018 Location: Bldg. RAB Floor El. +21 Room, Area Switchaear Room B SWEL Components: SWELl -002. 007. 068. 069. 097 Photographs Note: Temporary enclosure. Note: Example of temporary enclosure possibly having an impact on cabinet LCP-62.

Note: Example of resolution to seismic Note: Example of resolution to seismic concern. concern.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 671 of1014 Page 80 of 210 Sheet I of 5 Status: YM NL-- U--

Area Walk-By Checklist (AWC) AWC-020 Location: Bldg. RAB Floor El. +21 Room, Area, Component Cooling Pump B Room SWEL Components: SWELl-009 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YO NEi UI- N/A[I potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

0 Anchorage of nearby equipment is adequate.

2. Does anchorage of equipment in the area appear to be free of YN NEI] U-- N/A[-]

significant degraded conditions?

0 No corrosion found on any equipment anchorage.

3. Based on a visual inspection from the floor, do the cable/conduit YE NO] U-JE N/A[-1 raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 672 of1014 Page 81 of 210 Sheet 2 of 5 Status: YZ N[-] U--

Area Walk-By Checklist (AWC) AWC-020 Location: Bldg. RAB Floor El. +21 Room, Area Component Cooling Pump B Room

4. Does it appear that the area is free of potentially adverse seismic YIZ1 NEI U[ N/AL spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Y[ NO' U[-I N/AD interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YO NDI U-- N/AI-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[ NI- U[-1 N/A-]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 673 of1014 Page 82 of 210 Sheet 3 of 5 Status: YN NFI- U[--]

Area Walk-By Checklist (AWC) AWC-020 Location: Bldg. RAB Floor El. +21 Room, Area Component Cooling Pump B Room

8. Have you looked for and found no other seismic conditions that could YZ NIl U--

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Minor surface corrosion on valve CHWMVAAA863, no seismic concern; WR 288420 initiated to address issue Evaluated by: Brian Pace Date: 10-12-2012 Dinesh Patel 10-12-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 674 of 1014 Page 83 of 210 Sheet 4 of 5 Status: YX Nr- UF-Area Walk-By Checklist (AWC) AWC-020 Location: Bldg. RAB Floor El. +21 Room, Area Component Cooling Pump B Room SWEL Components: SWELl-009 Photographs Note: Minor surface corrosion on valve Note: Additional equipment in area.

CHWMVAAA863.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 675 of1014 Page 84 of 210 Sheet 5 of 5 Status: Y[ NEI U7 Area Walk-By Checklist (AWC) AWC-020 Location: Bldg. RAB Floor El. +21 Room, Area Comoonent Cooling Pump B Room SWEL Components: SWELl-009 Note: Properly mounted equipment in area. Note:

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 676 of1014 Page 85 of 210 Sheet I of 4 Status: YE NI- U1D Area Walk-By Checklist (AWC) AWC-021 Location: Bldg. RAB Floor El. +21 Room, Area' Hallway near CCW Pump AB Room SWEL Components: SWELl-094 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE NEI U-- N/AZI potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YE Ni] U-I N/AD-significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YE NEI UD- N/ADl raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

1If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 677 of1014 Page 86 of 210 Sheet 2 of 4 Status: YN NE] UEII]

Area Walk-By Checklist (AWC) AWC-021 Location: Bldg. RAB Floor El. +21 Room, Area Hallway near CCW Pump AB Room

4. Does it appear that the area is free of potentially adverse seismic Yi N] U-I N/AI-I spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages. Lights are in walkway and falling bulbs would not impact equipment, no seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YN N[-" U-- N/A[l interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic Y[ N[] UW- N/AI-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YE N[- U-- N/AW interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 678 of1014 Page 87 of 210 Sheet 3 of 4 Status: YEE N-- UFD Area Walk-By Checklist (AWC) AWC-021 Location: Bldg. RAB Floor El. +21 Room, Area Hallway near CCW Pump AB Room

8. Have you looked for and found no other seismic conditions that could YZ NEil Ur adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10/4/12 C hu-Chieh Lin . *- *10/4/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 679 ofO114 Page 88 of 210 Sheet 4 of 4 Status: YN NEI[ U-I Area Walk-By Checklist (AWC) AWC-021 Location: Bldg. RAB Floor El. +21 Room, Area Hallway near CCW Pump AB Room SWEL Components: SWELl-094 Photographs Note: Area around Nitrogen Accumulator #3 Note:

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 680 of'1014 Page 89 of 210 Sheet 1 of 5 Status: YZ NF U-Area Walk-By Checklist (AWC) AWC-022_

Location: Bldg. RAB Floor El. +21 Room, Area, CCW Pump A Room SWEL Components: SWELl -065. SWEL2-010. 011 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE NE] UE- N/AZ-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of Y[ NE-] Ui- N/AZD significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YM NEI] ui-- N/A--

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 681 ofl1014 Page 90 of 210 Sheet 2 of 5 Status: YM" NF- Ur-]

Area Walk-By Checklist (AWC) AWC-022 Location: Bldg. RAB Floor El. +21 Room, Area CCW Pump A Room

4. Does it appear that the area is free of potentially adverse seismic YZ NEJ UIZ N/A[:-

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5. Does it appear that the area is free of potentially adverse seismic YZ NEI uDI N/ADI interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YZ ND:] UD- N/AD-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YN NDI Uil N/ADI interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 682 of1014 Page 91 of 210 Sheet 3 of 5 Status: YN NE-- Ufl Area Walk-By Checklist (AWC) AWC-022 Location: Bldg. RAB Floor El. +21 Room, Area CCW Pump A Room

8. Have you looked for and found no other seismic conditions that could YZ N[l UM adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

" CHWMVAAA561 and CHWMVAAA563 are leaking; no seismic concern

  • Broken insulation near valve CHWMVAAA559; no seismic concern Evaluated by: Dinesh Patel Date: 10/4/12 Natalie George 10/4/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 683 of1014 Page 92 of 210 Sheet 4 of 5 Status: YX NiI U[i Area Walk-By Checklist (AWC) AWC-022_

Location: Bldg. RAB Floor El. +21 Room, Area CCW Pump A Room SWEL Components: SWEI-1-065. SWEI-2-O11. 012 Photouraphs Note: Valve CHWMVAAA561 is leaking Note: Valve CHWMVAAA563 is leaking

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 684 ofl 014 Page 93 of 210 Sheet 5 of 5 Status: YN ND] U[D Area Walk-By Checklist (AWC) AWC-022 Location: Bldg. RAB Floor El. +21 Room, Area CCW Pump A Room SWEL Components: SWELI-065. SWEL2-011. 012 Note: Broken insulation near valve CHWMVAAA559

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 685 of1014 Page 94 of 210 Sheet 1 of 5 Status: Y; ND- UI-]

Area Walk-By Checklist (AWC) AWC-023 Location: Bldg. RAB Floor El. +21 Room, AreaI CCW HX A Room SWEL Components: SWELl -090 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Y[ N[D] uiD N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YZ NEI UD-- N/A--

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YZ NEI UD- N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 686 of1014 Page 95 of 210 Sheet 2 of 5 Status: YZ NI I U-I Area Walk-By Checklist (AWC) AWC-023 Location: Bldg. RAB Floor El. +21 Room, Area CCW HX A Room

4. Does it appear that the area is free of potentially adverse seismic YN N[: U[I: N/A[D]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5. Does it appear that the area is free of potentially adverse seismic Y[ NEI UD-- N/A[-D interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YN NDi Ui N/AD-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YZ NDI UD-] N/A[-]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

  • Harnesses lying on ground near scaffolding; no seismic concern

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 687 of1014 Page 96 of 210 Sheet 3 of 5 Status: YN N-- UL-Area Walk-By Checklist (AWC) AWC-023 Location: Bldg. RAB Floor El. +21 Room, Area CCW HX A Room

8. Have you looked for and found no other seismic conditions that could YZ N[D UDI adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Valves CHWMVAAA554 and CHWMVAAA556 are leaking and show mild corrosion; no seismic concern; WR 288402 initiated to address CHWMVAAA554 issues, WR288404 initiated to address CHWMVAAA556 issues
  • Cover on drain below HX not secured; no seismic concern 6f~~ Cp~_ _

Evaluated by: Natalie Georqe Date: 10/4/12 Chu-Chieh Lin - 10/4/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 688 ofO 104 Page 97 of 210 Sheet 4 of 5 Status: YN NEI UI Area Walk-By Checklist (AWC) AWC-023 Location: Bldg. RAB Floor El. +21 Room, Area CCW HX A Room SWEL Components: SWELl-090 Photographs Note: Harnesses lying on ground near scaffolding Note: Valve CHWMVAAA554 is leaking and shows mild corrosion

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 689 of1014 Page 98 of 210 Sheet 5 of 5 Status: Y[* N*] U[D AWC-023 Area Walk-By Checklist (AWC)

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX A Room SWEL Components: SWELl-090 Note: Valve CHWMVAAA556 is leaking and Note: Cover on drain below HX not secured shows mild corrosion

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 690 of1014 Page 99 of 210 Sheet 1 of 5 Status: YM N ULI Area Walk-By Checklist (AWC) AWC-024_

Location: Bldg. RAB Floor El. +21 Room, Area' CCW HX B Room SWEL Components: SWELl-014. 021 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE Nr UD N/AD potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Anchorage of all equipment is in good condition.

2. Does anchorage of equipment in the area appear to be free of YZ NO U- N/AD significant degraded conditions?
  • Mild corrosion found on pipe support associated with valve CHW-873. No seismic concern.
3. Based on a visual inspection from the floor, do the cable/conduit YM N- UD N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 691 of1014 Page 100 of 210 Sheet 2 of 5 Status: YIZ N-- Ui-J Area Walk-By Checklist (AWC) AWC-024 Location: Bldg. RAB Floor El. +21 Room, Area CCW HX B Room

4. Does it appear that the area is free of potentially adverse seismic YN NU U-] N/AED spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Overhead fluorescent lights without cages are overhead. The fixture is well supported. Falling bulbs would have no impact on equipment in the area. There is no seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YN NDI uDI N/AD-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YE N[i UL- N/AE[

interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic YE NEI UEI N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
  • Minor housekeeping issues. A bucket and bottles located on the floor. No seismic concern.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 692 of1014 Page 101 of 210 Sheet 3 of 5 Status: YN N-I UD Area Walk-By Checklist (AWC) AWC-024 Location: Bldg. RAB Floor El. +21 Room, Area CCW HX B Room

8. Have you looked for and found no other seismic conditions that could YN NE] ULI--

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

" A group of valves have mild surface corrosion on the bolts and yokes (CHWMVAAA872, CHWMVAAA873, CHWMVAAA874, CHWMVAAA875)

  • CHWMVAAA876 has mild surface corrosion on the bolts and yokes
  • These pose no seismic concern.

Evaluated by: Brian Pace Date: 10-12-2012 Dinesh Patel 10-12-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 693 ofO104 Page 102 of 210 Sheet 4 of 5 Status: Y[ NF-] UFI Area Walk-By Checklist (AWC) AWC-024 Location: Bldg. RAB Floor El. +21 Room, Area CCW HX B Room SWEL Components: SWEL1-014. 021 Photographs Note: Valve CHW-874 mild surface corrosion. Note: Valve CHW-872 with mild surface corrosion.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 694 of1014 Page 103 of 210 Sheet 5 of 5 Status: Y[ NEIl UD-Area Walk-By Checklist (AWC) AWC-024_

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX B Room SWEL Components: SWELI-014. 021 Note: Mild corrosion on pipe support Note: Minor housekeeping issues.

associated with valve CHW-873.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 695 of1014 Page 104 of 210 Sheet 1 of 4 Status: YE ND UD Area Walk-By Checklist (AWC) AWC-025_

Location: Bldg. RAB Floor El. +21 Room, Area' Emergency Diesel Generator B Room SWEL Components: SWEI-1 -043. 072. 081 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YZ N[-I U[-] N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YZ N[D] UD- N/A[--

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YZ NDI U-I N/AD1 raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 696 of'1014 Page 105 of 210 Sheet 2 of 4 Status: YZ NI ULIJ Area Walk-By Checklist (AWC) AWC-025 Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator B Room

4. Does it appear that the area is free of potentially adverse seismic YE NEI UI N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages, but falling bulbs will have not impact on equipment in the room. This is no seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YZ NDI U[I N/AD interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YZ ND UD N/AD interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YE NEI U-D N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
  • Two unsecured disposal cans in front of panel but would have no adverse effect on the panel if it was impacted by cans.

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 697 of1014 Page 106 of 210 Sheet 3 of 4 Status: YN Nil U--

Area Walk-By Checklist (AWC) AWC-025 Location: Bldg. RAB Floor El. +21 Room, Area Emer-qency Diesel Generator B Room

8. Have you looked for and found no other seismic conditions that could YN Nil UD-adversely affect the safety functions of the equipment in the area?
  • Conduits rigidly attached to equipment are acceptable per drawing no. B288 sh. 19-1 Comments (Additional pages may be added as necessary)
  • Electrical junction box 2 (conduit 222-7909002-21) has two missing bolts and one loose bolt (out of 14 total); no seismic concern
  • Valves EGFMVAAA126B and EGFMVAAA1 27B near support EGRR-3019 show mild corrosion; no seismic concern Evaluated by: Dinesh Patel Date: 10/2/12 Brian Pace 10/2/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 698 of1014 Page 107 of 210 Sheet 4 of 4 Status: Y[ Nr-] UrI-Area Walk-By Checklist (AWC) AWC-025 Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator B Room SWEL Components: SWELl-043, 072. 081 Photographs Note: Electrical junction box 2 has two missing Note: Mild corrosion on valves EGFMVAAA126B bolts and one loose bolt and EGFMVAAA127B

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 699 of1014 Page 108 of 210 Sheet I of 4 Status: YZ ND ULI Area Walk-By Checklist (AWC) AWC-028 Location: Bldg. RB Floor El. -35 Room, Area, RB -35 Central Area SWEL Components: SWELl -025, 052, 053, 054, 055, 057, 058 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YNJ NO U-I N/AD--

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of YZ NO U[-I N/A[-]

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YM N- ULI N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

1If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F17-2013-0024 Rev. 0 Page 700 of1014 Page 109 of 210 Sheet 2 of 4 Status: YE NM UM Area Walk-By Checklist (AWC) AWC-028 Location: Bldg. RB Floor El. -35 Room, Area RB -35 Central Area

4. Does it appear that the area is free of potentially adverse seismic YDZ] NEI U[1 N/AU spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages but will not affect equipment if bulbs fall. Fixture is rigid.
5. Does it appear that the area is free of potentially adverse seismic Y] N[-] U0 N/A[D]

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Y[J NO U-- N/A-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[ N- UE N/AE--

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 701 of1014 Page 110of210 Sheet 3 of 4 Status: YN NEII U-Area Walk-By Checklist (AWC) AWC-028 Location: Bldg. RB Floor El. -35 Room, Area RB -35 Central Area

8. Have you looked for and found no other seismic conditions that could YN NE-] U[-

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Clip on SI MVAAA225A not secure; no seismic concern
  • Hoses on ground due to work in progress; no seismic concern
  • Leak on BD MPMPOO04. WO#319512 addresses this leak. No seismic concern.
  • One clip on insulation of pipe associated with valve SI MVAAA1 38-B is broken near the elbow.

No seismic concern.

Evaluated by: Dinesh Patel Date: 10-15-2012 Brian Pace 10-15-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 702 ofl 014 Page 111 of 210 Sheet 4 of 4 Status: YX Njj1 UFI Area Walk-By Checklist (AWC) AWC-028 Location: Bldg. RB Floor El. -35 Room, Area RB -35 Central Area SWEL Components: SWELl -025. 052. 053. 054. 055. 057. 058 Photographs Note: Leak addressed by WO#319512 Note: Clip on SI MVAAA225A not secure Note: Broken clip on insulation around pipe associated with valve SI MVAAA138-B.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 703 of1014 Page 112 of 210 Sheet 1 of 5 Status: YZ ND-- UD-Area Walk-By Checklist (AWC) AWC-029_

Location: Bldg. RB Floor El. -35 Room, Area' Diesel Oil Storage Tank A Room SWEL Components: SWELl -011, 093 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YO ND UD N/A-1 potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

0 Anchorage of equipment is free of adverse conditions.

2. Does anchorage of equipment in the area appear to be free of YO NDI UD N/AD significant degraded conditions?
  • Corrosion and minor oil leaks found on valves near the tank (EGFMVAAA1 04-A and EGFMVAAA1 061 and EGFMVAAA1 05A).

" Corrosion found on sump pumps SP EMTR213B-7B and SP EMTR213A-7B in the area.

" The level gauge attached to the tank had minor surface corrosion.

  • Two pipe supports above this equipment had corroded bolts.
  • No seismic concerns due to these issues.
3. Based on a visual inspection from the floor, do the cable/conduit Y; NDI uD N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 704 of1014 Page 113 of 210 Sheet 2 of 5 Status: YZ NE] UFI Area Walk-By Checklist (AWC) AWC-029 Location: Bldg. RB Floor El. -35 Room, Area Diesel Oil Storage Tank A Room

4. Does it appear that the area is free of potentially adverse seismic Y[ Ni-] uLi N/AF]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5. Does it appear that the area is free of potentially adverse seismic YZ N[-- U[- N/A-I interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YO NEI] Ul-] N/AL]

interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic Y] NEI Ul-] N/AL]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 705 of'1014 Page 114of 210 Sheet 3 of 5 Status: YN NEI U[--

Area Walk-By Checklist (AWC) AWC-029 Location: Bldg. RB Floor El. -35 Room, Area Diesel Oil Storage Tank A Room

8. Have you looked for and found no other seismic conditions that could YN N[] UI--

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10/5/12 Dinesh Patel 10/5/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 706 of1014 Page 115of 210 Sheet 4 of 5 Status: YN NRI- Ur]

Area Walk-By Checklist (AWC) AWC-029_

Location: Bldg. RB Floor El. -35 Room, Area Diesel Oil Storage Tank A Room SWEL Components: SWELl-0il. 093 Photographs Note: Valve EGFMVAAA1 04-A surface Note: Valve EGFMVAAA1 061 with mild surface corrosion. corrosion.

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 707 of1014 Page 116 of 210 Sheet 5 of 5 Status: Y[ NIL-- UDF Area Walk-By Checklist (AWC) AWC-029 Location: Bldg. RB Floor El. -35 Room, Area Diesel Oil Storage Tank A Room SWEL Components: SWELl-011, 093 Note: Sump pumps SP EMTR213A-7B and Note: Pipe support with corroded bolts.

SP EMTR213B-7B near tank have mild surface corrosion.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 708 of1014 Page 117 of 210 Sheet 1 of 5 Status: YZ ND UD-]

Area Walk-By Checklist (AWC) AWC-030_

Location: Bldg. RB Floor El. -4 Room, Areal B100/10A- M SWEL Components: SWEL1 -01 7, 022. 033. 076 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN N[D U-I N/AD--

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of Y[] NO UD- N/AD--

significant degraded conditions?

. Bolt displays mild corrosion; no seismic concern

3. Based on a visual inspection from the floor, do the cable/conduit YE NEI U[] N/AD-raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

'If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 709 of1014 Page 118 of 210 Sheet 2 of 5 Status: YN N[- UFD Area Walk-By Checklist (AWC) AWC-030 Location: Bldg. RB Floor El. -4 Room, Area B100 / 10A -. M

4. Does it appear that the area is free of potentially adverse seismic YN NEI U[I N/ADI spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic Y[Z NDI UDi N/AD-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YO NEI UE* N/AL interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YE] NIZ UDI N/ALE interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
  • Barrels near column 10A, line N are not properly secured. See LB-05 in Attachment F.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 710 of1014 Page 119of 210 Sheet 3 of 5 Status: YE N--I ULI Area Walk-By Checklist (AWC) AWC-030 Location: Bldg. RB Floor El. -4 Room, Area B100 / 10A - M

8. Have you looked for and found no other seismic conditions that could YN N[] UM adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Damage to jacketing near valve BD MVAAA107-A, potential insulation damage; no seismic concern
  • Mild corrosion on valves throughout; no seismic concern
  • C Evaluated by: Natalie Georqe Date: 10/5/12 Chu-Chieh Lin 6- 10/5/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 711 of1014 Page 120 of 210 Sheet 4 of 5 Status: YN NO U--

Area Walk-By Checklist (AWC) AWC-0307 Location: Bldg. RB Floor El. -4 Room, Area B100/10A - M SWEL Components: SWEILl -01 7. 022. 033. 076 Photographs Note: Bolts display mild corrosion Note: Fluorescent lights do not have cages.

Falling bulbs will not damage equipment and is not a seismic concern.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 712 of1014 Page 121 of 210 Sheet 5 of 5 Status: Y" NF- UFI Area Walk-By Checklist (AWC) AWC-030 Location: Bldg. RB Floor El. -4 Room, Area B100/10A- M SWEL Components: SWELl -017. 022, 033, 076 Note: Barrels near column 10A, line N are not Note: Damage to jacketing near valve properly secured BD MVAAA1 07-A; potential insulation damage

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 713 of1014 Page 122 of 210 Sheet 1 of 5 Status: YZ ND] UL-Area Walk-By Checklist (AWC) AWC-032 Location: Bldg. RAB Floor El. +46 Room, Area' Control Room SWEL Components: SWEL-084, 085, 086 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Y[ NO UD N/AD potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of Y[ NEI UD N/AD significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YE NO U- N/A[-D raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 714 of1014 Page 123 of 210 Sheet 2 of 5 Status: YM Ni I U--

Area Walk-By Checklist (AWC) AWC-032 Location: Bldg. RAB Floor El. +46 Room, Area Control Room

4. Does it appear that the area is free of potentially adverse seismic YEE NO] Ur- N/A--I spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YZ NEI Ut] N/At]

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic YN NI UtII N/ALI interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YN NE] Ut] N/A[]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Book eaes and trash can next to IC ECPO8 should be moved o r R

bolted (anchored), book case adjacent to IC ECP22 should be moved or bolted, trash can in front of IC ECP1 1B should be moved o After reevaluation of these components, it was determined that all loose items in the control room are anchored. Calculation ECC-095-005 was issued for the loose items in the control room after IPEEE identified these same issues.

o The trash cans were also determined to be made of material that could not damage the surrounding cabinets.

Table and trash can next to IC ECP20 should be moved o This is not a seismic concern because it is next to Non-Safety Related equipment, but must be moved for personnel safety.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 715 of1014 Page 124 of 210 Sheet 3 of 5 Status: Y[L NE] U-Area Walk-By Checklist (AWC) AWC-032 Location: Bldg. RAB Floor El. +46 Room, Area Control Room

8. Have you looked for and found no other seismic conditions that could YE NE] Ur]

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Natalie George Date: 10/8/12 Chu-Ohieh Lin *L (

  • 10/8/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 716 of1014 Page 125 of 210 Sheet 4 of 5 Status: YX N'] U--

Area Walk-By Checklist (AWC) AWC-032 Location: Bldg. RAB Floor El. +46 Room, Area Control Room SWEL Components: SWEL-084, 085. 086 Photographs Note: Book case and trash can next to IC ECP08 Note: Book case adjacent to IC ECP22 should be should be moved or bolted (anchored) (Determined moved or bolted (Determined to be anchored) to not be an issue)

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 717 of1014 Page 126 of 210 Sheet 5 of 5 Status: Y[Z NEI U[--I Area Walk-By Checklist (AWC) AWC-032 Location: Bldg. RAB Floor El. +46 Room, Area Control Room SWEL Components: SWEL-084, 085, 086 Note: Table and trash can next to IC ECP20 should be moved

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 718 of1014 Page 127 of 210 Sheet 1 of 5 Status: YN NF] UL-Area Walk-By Checklist (AWC) AWC-035 Location: Bldg. RAB Floor El. +46 Room, Area, Emergency Diesel Oil Feed Tank A Room SWEL Components: SWELl-074 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Y: ND-] Ul N/AL]

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

  • All anchorage of nearby equipment, including the Diesel Oil Feed Tank A, is in good condition.
2. Does anchorage of equipment in the area appear to be free of Y< NEI JO N/A--

significant degraded conditions?

0 No degraded conditions found on anchors.

3. Based on a visual inspection from the floor, do the cable/conduit YN NDI ulD N/ADI raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 719 of1014 Page 128 of 210 Sheet 2 of 5 Status: YZ NDI UD-Area Walk-By Checklist (AWC) AWC-035 Location: Bldg. RAB Floor El. +46 Room, Area Emeraqency Diesel Oil Feed Tank A Room

4. Does it appear that the area is free of potentially adverse seismic YN NE I UE] N/A[D spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YZ ND- U[D] N/ADl interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YE NDI U[D] N/AD--

interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic YO NDI uiDl N/ADI interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
  • A wrench located on top of a structural steel member could fall and damage valve nearby.

0 The wrench was removed and brought to the tool room, solving the potentially adverse seismic condition.

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 720 of1014 Page 129 of 210 Sheet 3 of 5 Status: YZ NEI UFI Area Walk-By Checklist (AWC) AWC-035 Location: Bldg. RAB Floor El. +46 Room, Area Emergency Diesel Oil Feed Tank A Room

8. Have you looked for and found no other seismic conditions that could YE NI] UIý adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Oil leak from diesel tank flange. Currently being resolved with WR#232292 and CR#11-1860.

No seismic concern.

  • One drain valves had a slight leak on it as well. No seismic concern.

Evaluated by: Brian Pace Date: 10-08-2012 Dinesh Patel 10-08-2012

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 721 of1014 Page 130 of 210 Sheet 4 of 5 Status: Y; NII Uti--

Area Walk-By Checklist (AWC) AWC-035 Location: Bldg. RAB Floor El. +46 Room, Area Emergency Diesel Oil Feed Tank A Room SWEL Components: SWELl-074 Note: Wrench with potential adverse seismic Note: Leak on the diesel oil feed tank.

condition. Note that the wrench was removed and brought to the tool room, removing the condition.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 722 ofl1014 Page 131 of 210 Sheet 5 of 5 Status: YN NEI UD--

Area Walk-By Checklist (AWC) AWC-035 Location: Bldg. RAB Floor El. +46 Room, Area Emergency Diesel Oil Feed Tank A Room SWEL Components: SWELl -074 Note:

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 723 ofl 014 Page 132 of 210 Sheet 1 of 5 Status: YE ND UDl Area Walk-By Checklist (AWC) AWC-036 Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area SWEL Components: SWELl -032. 063 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YM NDI UD N/A--

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

0 Anchorage of equipment appears to be in good condition

2. Does anchorage of equipment in the area appear to be free of YO NDI UD N/AD-significant degraded conditions?
  • Valve CHWMVAAA201 has surface corrosion on yoke plate and bolts, CR-WF3-2012-05627 and WR 288441 initiated to address corrosion; not a seismic concern
  • Bolt and pipe clamp on pipe support near fan E-28 has surface corrosion; not a seismic concern
3. Based on a visual inspection from the floor, do the cable/conduit Y[ NDI UD- N/A[D raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 724 of1014 Page 133 of 210 Sheet 2 of 5 Status: YZ ND-- UD--

Area Walk-By Checklist (AWC) AWC-036 Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area

4. Does it appear that the area is free of potentially adverse seismic YN NEI UD N/A-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Overhead lighting is not above any equipment

5. Does it appear that the area is free of potentially adverse seismic YN ND UD N/AD interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YIZ ND U[D1 N/AD1 interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YE NDI UD_ N/AD1 interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 725 of1O14 Page 134 of 210 Sheet 3 of 5 Status: YI* Nl-I UL-I (AWC) AWC-036 Area Walk-By Checklist Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area

8. Have you looked for and found no other seismic conditions that could YN N[i U[-

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

. Crushed insulation on pipe on top of scaffolding by fan E-28; not a seismic concern Evaluated by: Dinesh Patel Date: 10-08-2012 Brian Pace 10-08-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 726 of1014 Page 135 of 210 Sheet 4 of 5 Status: Y; NEI U--

Area Walk-By Checklist (AWC) AWC-036 Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area SWEL Components: SWELl -032. 063 Photographs Note: Surface corrosion on valve Note: Surface corrosion on valve CHWMVAAA201 CHWMVAAA201 from underneath

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 727 of1014 Page 136 of 210 Sheet 5 of 5 Status: YZ N-- U-I Area Walk-By Checklist (AWC) AWC-036 Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area SWEL Components: SWELl -032. 063 Note: Surface corrosion on pipe clamp on pipe Note: Crushed insulation on pipe lying on support near fan E-28 scaffolding near fan E-28

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 728 of1014 Page 137 of 210 Sheet I of 6 Status: Y[ NEI UFD Area Walk-By Checklist (AWC) AWC-037 Location: Bldg. RAB Floor El. +46 Room, Area, NORTHWEST RAB +46 AREA SWEL Components: SWELl -031, 041. 049. 050. 067. 088 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YZ NDI UD- N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YN NEI U-- N/A[D significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YM NDI U-- N/AD]

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 729 of1014 Page 138 of 210 Sheet 2 of 6 Status: Y] NEI UE]

Area Walk-By Checklist (AWC) AWC-037 Location: Bldg. RAB Floor El. +46 Room, Area NORTHVA'EST RAB +46 AREA

4. Does it appear that the area is free of potentially adverse seismic Y[-] NE U[-I N/A[]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

0 Chain from crane should be re-positioned so it will not interaction w/ panel or piping; see LB-06 in Attachment F.

5. Does it appear that the area is free of potentially adverse seismic YZ NEI UEl N/AL]

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic Y[ NE] UL] N/A[L]

interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic YZ NL] UEL N/A[-]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 730 of1014 Page 139 of 210 Sheet 3 of 6 Status: YN NI 1 UDI Area Walk-By Checklist (AWC) AWC-037 Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA

8. Have you looked for and found no other seismic conditions that could YEI NE] UI-adversely affect the safety functions of the equipment in the area?

" Severe corrosion on valves CHWMVAAA121A and CHWMVAAA788A o CR-WF3-2012-06472 and WO 196829 initiated for CHWMVAAA121A.

o CR-WF3-2012-05372 and WR287812 were initiated for CHWMVAAA788A.

" Severe corrosion and leakage on valves CHWMVAAA127B, CHWMVAAA436, and CHWMVAAA881 o CR-WF3-2012-05372 and WR 287813 initiated for CHWMVAAA127B.

o CR-WF3-2012-05089 and WR 286898 and WR 286900 already written for CHWMVAAA436 and CHWMVAAA887.

Comments (Additional pages may be added as necessary)

  • Mild corrosion and leakage on pump CHWMPMPOO01B, no seismic concern; CR-WF3-2010-05497 and WR 212221 in-progress to address issues
  • Loose screws inside of pump CHWMPMPOO01B, no seismic concern; WR 287826 initiated to address issue
  • Mild corrosion and leakage on valves CHWMVAAA248, CHWMVAAA550, CHWMVAAA1341B, and CHWMVAAA1343B, no seismic concern o WR 287824 initiated for CHWMVAAA248, CR-WF3-2012-05732 and WR 287815 and WR 287816 written for CHWMVAAA1341B and CHWMVAAA1343B, WR 44875 in-progress for CHWMVAAA550 Evaluated by: Natalie Georqe Date: 10/15/12 Chu-Chieh Lin 10/15/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 731 of1014 Page 140 of 210 Sheet 4 of 6 Status: YZ NEI UL-I Area Walk-By Checklist (AWC) AWC-037 Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA SWEL Components: SWELl-031, 041, 049, 050, 067, 088 Photographs

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 732 oflO14 Page 141 of 210 Sheet 5 of 6 Status: YN NI-- UD-Area Walk-By Checklist (AWC) AWC-037 Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA SWEL Components: SWELl -031, 041, 049, 050, 067, 088 Note: Mild corrosion and leakage on valve CHWMVAAA1 341 B Note: Mild corrosion and leakage on valve CHWMVAAA248

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 733 of'1014 Page 142 of 210 Sheet 6 of 6 Status: YZ NFIl UEI Area Walk-By Checklist (AWC) AWC-037 Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA SWEL Components: SWELl-031. 041. 049. 050. 067. 088 Note: Mild corrosion and leakage on valve Note: Severe corrosion and leakage on valve CHWMVAAA550 CHWMVAAA436 Note: Severe corrosion and leakage on valve Note: Chain from crane should be re-positioned CHWMVAAA881 so it will not interaction w/ panel or piping

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 734 of1014 Page 143 of 210 Sheet I of 4 Status: YN Nf-- U--

Area Walk-By Checklist (AWC) AWC-038 Location: Bldg. RAB Floor El. +46 Room, Area, Emergency Vent Air Clean Up Units Area SWEL Components: SWELI-029, 061. 062. 064 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE NEI UEi N/AL]

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of YZ N[] U-IJ N/ADl significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YZ NEI U[Z N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 735 of1014 Page 144 of 210 Sheet 2 of 4 Status: YN NDý ULIl Area Walk-By Checklist (AWC) AWC- 038 Location: Bldg. RAB Floor El. +46 Room, Area Emergency Vent Air Clean Up Units Area

4. Does it appear that the area is free of potentially adverse seismic Y[O ND- UD:- N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YE N[D- UD-- N/AD-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YN N[D) UED N/AD1 interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YZ ND] UD1 N/AD]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 736 of1014 Page 145 of 210 Sheet 3 of 4 Status: Y; NO U-III Area Walk-By Checklist (AWC) AWC- 038 Location: Bldg. RAB Floor El. +46 Room, Area Emergency Vent Air Clean Up Units Area

8. Have you looked for and found no other seismic conditions that could Yo NE] UI--

adversely affect the safety functions of the equipment in the area?

  • Block wall in area acceptable per drawing no. G765 sh. 2, calculation no. Civil Seismic Block Walls, and FSAR Section 3.8.4.8 Comments (Additional pages may be added as necessary)
  • Damage to insulation on HVC-215A and AH-12B; no seismic concern Evaluated by: Natalie George Date: 10/9/12 Chu-Chieh Lin - L * " -- 10/9/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 737 ofO114 Page 146 of 210 Sheet 4 of 4 Status: YZ N[-- U--

Area Walk-By Checklist (AWC) AWC- 038 Location: Bldg. RAB Floor El. +46 Room, Area Emergency Vent Air Clean Urp Units Area SWEL Components: SWELl -029, 061, 062. 064 Photoaraohs Note: Damage to insulation on HVC-215A Note: Damage to insulation on AH-12B

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 738 of1014 Page 147 of 210 Sheet 1 of 5 Status: YE ND- UD-Area Walk-By Checklist (AWC) AWC-039_

Location: Bldg. RAB Floor El. +46 Room, Area, AH-25B Room SWEL Components: SWELI-042 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE NDi UD N/A--

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

All components in the vicinity of CHWMVAAA900 are well anchored.

2. Does anchorage of equipment in the area appear to be free of YE] ND] UDl N/AD-significant degraded conditions?
  • Mild surface corrosion on bolt on AH-25B and steel along bottom of air handler, but this poses no seismic impact; WR 288417 initiated to address corrosion
3. Based on a visual inspection from the floor, do the cable/conduit YN NDI uDl N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 739 of1014 Page 148 of 210 Sheet 2 of 5 Status: Y[ ND] UD-Area Walk-By Checklist (AWC) AWC-039 Location: Bldg. RAB Floor El. +46 Room, Area AH-25B Room

4. Does it appear that the area is free of potentially adverse seismic YE N- U-I N/A[--

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

  • Overhead lighting has no covers, but falling bulbs would have no impact on equipment underneath. Fixtures are well supported.
5. Does it appear that the area is free of potentially adverse seismic Y[ NDI UD N/AD--

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic YN ND U[D] N/AD interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YO ND UD N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
  • Unsecured tool box is in designated storage area.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 740 of1014 Page 149 of 210 Sheet 3 of 5 Status: Y[* Nj- UL--

Area Walk-By Checklist (AWC) AWC-039 Location: Bldg. RAB Floor El. +46 Room, Area AH-25B Room

8. Have you looked for and found no other seismic conditions that could YN NI'] UM adversely affect the safety functions of the equipment in the area?

" There is a piece of steel tied with a rope to base plate at two locations. Once of them is near a valve. It was determined that the steel piece in the vicinity of this valve could not make impact with the valve during a seismic event. Therefore, this is no seismic concern.

  • Three ladders in the area are all well secured.

Comments (Additional pages may be added as necessary) 0 Loose insulation near AH-25B; no seismic concern.

Evaluated by: Dinesh Patel Date: 10-09-2012 Brian Pace 10-09-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 741 ofl014 Page 150 of 210 Sheet 4 of 5 Status: Y[] NEI UIII (AWC) AWC-039 Area Walk-By Checklist Location: Bldg. RAB Floor El. +46 Room, Area AH-25B Room SWEL Components: SWELl-042 Photographs Note: Hanging steel determined not to have Note: Corrosion on bolt and surrounding steel an impact on the nearby valves. at the bottom of AH-25B.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 742 of1014 Page 151 of 210 Sheet 5 of 5 Status: YN NFD U--

Area Walk-By Checklist (AWC) AWC-039_

Location: Bldg. RAB Floor El. +46 Room, Area AH-25B Room SWEL Components: SWELl -042 Note: Insulation is loose, near AH-25B. Note:

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 743 of'1014 Page 152 of 210 Sheet I of 5 Status: YN NFI UD-Area Walk-By Checklist (AWC) AWC-040 Location: Bldg. RAB Floor El. +91 Room, Area, CCW Surge Tank Area SWEL Components: SWELl-073, 091 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE NDI UD N/A-I potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

0 Anchorage of equipment is in good condition.

2. Does anchorage of equipment in the area appear to be free of Y[I ND U- N/AD significant degraded conditions?
  • Slight surface corrosion on two base plates for pipe supports on LS-CC-701 1 BS; WR 288395 initiated to address corrosion
3. Based on a visual inspection from the floor, do the cable/conduit Y[K N' UD N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 744 of1014 Page 153 of 210 Sheet 2 of 5 Status: YN N[I U[I Area Walk-By Checklist (AWC) AWC-040 Location: Bldg. RAB Floor El. +91 Room, Area CCW Surge Tank Area

4. Does it appear that the area is free of potentially adverse seismic YE N[] U-I N/A[I spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Y[I NEi ULI N/AD-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YIZ NE] UL- N/AD1 interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[K NEI U[J N/A[-D interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 745 of1014 Page 154 of 210 Sheet 3 of 5 Status: YN NEI UF-1 Area Walk-By Checklist (AWC) AWC-040 Location: Bldg. RAB Floor El. +91 Room, Area CCW Surge Tank Area

8. Have you looked for and found no other seismic conditions that could YZ NE] UM adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-08-2012 Dinesh Patel 10-08-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 746 of1014 Page 155 of 210 Sheet 4 of 5 Status: YN NEI UI--

Area Walk-By Checklist (AWC) AWC-040 Location: Bldg. RAB Floor El. +91 Room, Area CCW Surge Tank Area SWEL Components: SWEL1 -073, 091 Photographs an IMIhore 1-o w.al-IbI VV aLJ WLtio Tank well Note: All additional valves and level switches anchored from walk-by observations. well supported and cause no spatial interaction concerns.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 747 ofl 014 Page 156 of 210 Sheet 5 of 5 Status: YZ NFI- U[-I Area Walk-By Checklist (AWC) AWC-040 Location: Bldg. RAB Floor El. +91 Room, Area CCW Surge Tank Area SWEL Components: SWELl-073, 091 Note: Surfa (one of Note:

Nte two shown).

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 748 of1014 Page 157 of 210 Sheet 1 of 5 Status: YE NFD U--

Area Walk-By Checklist (AWC) AWC-041 Location: Bldg. RB Floor El. +46 Room, Area AH-32, 34, 35 ROOM (ON ROOF)

SWEL Components: SWELl-078 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE NO ur-] N/AD1 potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YO NO U- N/AD significant degraded conditions?

" Degradation of concrete pad near embedded plates to which legs of tank NG-MACC-005 are welded, adverse seismic concern; identified in CR-WF3-2012-05278 and WR 287650

  • Cracks in concrete near embedded plates to which legs of tank NG-MACC-006 are welded, adverse seismic concern; identified in CR-WF3-2012-05278 and WR 287650
3. Based on a visual inspection from the floor, do the cable/conduit YEr NO U- N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
  • Severe corrosion on support for conduit lines 32095G-NB and 32095F-NB, adverse seismic concern; CR-WF3-2012-05203 and WR 287462 initiated to address corrosion

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 749 of1014 Page 158 of 210 Sheet 2 of 5 Status: YV7 Ni- U-I Area Walk-By Checklist (AWC) AWC-041 Location: Bldg. RB Floor El. +46 Room, Area AH-32, 34, 35 ROOM (ON ROOF)

4. Does it appear that the area is free of potentially adverse seismic YX NEI U-IZ N/AF-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Y[ N- U- N/AD-interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YZ NEI UD N/A-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YZ NO UO N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 750 of1014 Page 159 of 210 Sheet 3 of 5 Status: YIZ* ND U[III Area Walk-By Checklist (AWC) AWC-041 Location: Bldg. RB Floor El. +46 Room, Area AH-32. 34, 35 ROOM (ON ROOF)

8. Have you looked for and found no other seismic conditions that could Y[ NEI UFI adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

" Water pooling in recessed embedded plates, no seismic concern; CR-WF3-2012-05278 and WR's 287643, 287645, 287646, and 287650 initiated to address issue Evaluated by: Natalie George Date: 10/5/12 Chu-Chieh Lin - i 10/5/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 751 of1014 Page 160 of 210 Sheet 4 of 5 Status: Y; NRI- UF-Area Walk-By Checklist (AWC) AWC-041 Location: Bldg. RB Floor El. +46 Room, Area AH-32, 34, 35 ROOM (ON ROOF)

SWEL Components: SWELl-078 Photographs Mv.

Note: Degradation of concrete pad near Note: Cracks in concrete near embedded plates embedded plates to which legs of tank NG-MACC- to which legs of tank NG-MACC-006 are welded 005 are welded

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 752 of1O14 Page 161 of 210 Sheet 5 of 5 Status: YO ND-- Ur-Area Walk-By Checklist (AWC) AWC-041 Location: Bldg. RB Floor El. +46 Room, Area AH-32. 34, 35 ROOM (ON ROOF)

SWEL Components: SWELl-078 Note: Water pooling in recessed embedded plates MVAAA124 AB

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 753 of`1014 Page 162 of 210 Sheet I of 5 Status: YM NE] U--

Area Walk-By Checklist (AWC) AWC-042 Location: Bldg. RB Floor El. +46 Room, Area West Wing Area SWEL Components: SWEL1 -001. 034. 044. 045. 046 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YO NEI ULI N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YZ NDi UD N/AD]

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YZ N[D] U[: N/AD-raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 754 of1014 Page 163 of 210 Sheet 2 of 5 Status: Y[7 ND UD-I Area Walk-By Checklist (AWC) AWC-042 Location: Bldg. RB Floor El. +46 Room, Area West Winq Area

4. Does it appear that the area is free of potentially adverse seismic YEZ NE] UDI N/A-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YE NDI UD N/AD]

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic YE ND-- UD N/AD-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YM NDl UD- N/AD--

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 755 of1014 Page 164 of 210 Sheet 3 of 5 Status: YI* N[-- U--II Area Walk-By Checklist (AWC) AWC-042 Location: Bldg. RB Floor El. +46 Room, Area West Wing Area

8. Have you looked for and found no other seismic conditions that could YN N[-] UI-adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Mild corrosion throughout, on supports, valves, etc., no seismic concern; CR-WF3-2012-05278 and WR's 287643, 287645, 287646, and 287650 initiated to address corrosion
  • Water pooling at base of pipe support, recessed embedded plate; no seismic concern Evaluated by: Natalie George Date: 10/5/12 Chu-Chieh Lin -:  ! *t3-*10/5/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 756 of'1014 Page 165 of 210 Sheet 4 of 5 Status: Y[* Nl UD--

(AWC) AWC-042 Area Walk-By Checklist Location: Bldg. RB Floor El. +46 Room, Area West Wing Area SWEL Components: SWELl -001. 034. 044. 045. 046 Photographs riuLVu IVIIIU GU((OSIOI1 011 bUPPU[Lb L[1[UUUYF1UL dF~dd j1 urrubiuri (Al VdIVt~b tnirUUYnIUUL Wdtd Note: Mild corrosion on supports throughout area Note: Mild corrosion on valves throughout area

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 757 ofO114 Page 166 of 210 Sheet 5 of 5 Status: YZ N-- UD--

Area Walk-By Checklist (AWC) AWC-042 Location: Bldg. RB Floor El. +46 Room, Area West Wina Area SWEL Components: SWELI-O01 034, 044, 045. 046 Note: Mild corrosion on valves throughout area Note: Water pooling at base of pipe support Note: Mild corrosion on valves throughout area and dent on the pipe

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 758 of1014 Page 167 of 210 Sheet I of 4 Status: Y[* NiD ul--

Area Walk-By Checklist (AWC) AWC-043 Location: Bldg. RB Floor El. +46 Room, Area Southeast Wing Area SWEL Components: SWELl-035 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NEI UD- N/AD:

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of YE ND: UI- N/AD-significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YM NO UDi N/AD]

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 759 of1014 Page 168 of 210 Sheet 2 of 4 Status: YZ NEI U[7 Area Walk-By Checklist (AWC) AWC-043 Location: Bldg. RB Floor El. +46 Room, Area Southeast Wing Area

4. Does it appear that the area is free of potentially adverse seismic YN NEI UlI N/A[7 spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Y[ NI- U[7 N/AD-interactions that could cause flooding or spray in the area?

/

6. Does it appear that the area is free of potentially adverse seismic Y[ NDI UD N/AD7 interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YO NEI U-- N/AD1 interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 760 of1014 Page 169 of 210 Sheet 3 of 4 Status: YM NI- U[D Area Walk-By Checklist (AWC) AWC-043 Location: Bldg. RB Floor El. +46 Room, Area Southeast Winc] Area

8. Have you looked for and found no other seismic conditions that could Y[ N[: ULI--

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Valve MS MVAAA124-B62 is leaking, previously documented and funnel in place Evaluated by: Natalie George Date: 10/5/12 Chu-Chieh Lin 10/5/12

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 761 of1014 Page 170 of 210 Sheet 4 of 4 Status: YN NF-I ULI Area Walk-By Checklist (AWC) AWC-043 Location: Bldg. RB Floor El. +46 Room, Area Southeast Wing Area SWEL Components: SWELl-035 Photographs Note: Corrosion throughout area Note: Valve MS MVAAA124-B62 is leaking, previously documented and funnel in place

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 762 of1014 Page 171 of 210 Sheet 1 of 4 Status: YN NR UL-Area Walk-By Checklist (AWC) AWC-044_

Location: Bldg. RB Floor El. +46 Room, Area Northeast Wing Area SWEL Components: SWELI -027, 028 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YZ NEI UO N/A--

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of Y[ NEI U-D N/A-]

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YZ ND- U[] N/A[D]

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 763 of'1014 Page 172 of 210 Sheet 2 of 4 Status: YE NEIl U--

Area Walk-By Checklist (AWC) AWC-044 Location: Bldg. RB Floor El. +46 Room, Area Northeast Wing Area

4. Does it appear that the area is free of potentially adverse seismic YE NEI U-I N/AOl spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YN NE] U-I N/AZ interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YN NEI u-- N/AD interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YO NDI U* N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 764 of1014 Page 173 of 210 Sheet 3 of 4 Status: YN ND ULI Area Walk-By Checklist (AWC) AWC-044 Location: Bldg. RB Floor El. +46 Room, Area Northeast Wing Area

8. Have you looked for and found no other seismic conditions that could YN NEI Uil adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

" Mild corrosion throughout area, no seismic concern; CR-WF3-2012-05207, CR-WF3-2012-05278, WR 287493, WR 287643, WR 287645, WR 287646, and WR 287650 initiated to address issue

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 765 ofI 014 Page 174 of 210 Sheet 4 of 4 Status: YZ Nr-] UD-Area Walk-By Checklist (AWC) AWC-044 Location: Bldg. RB Floor El. +46 Room, Area Northeast Wing Area SWEL Components: SWELl -027, 028 Photographs Note: Corrosion throughout area Water pooling in structural support

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 766 of1014 Page 175 of 210 Sheet 1 of 4 Status: YN NFI- UFL Area Walk-By Checklist (AWC) AWC-045 Location: Bldg. RAB Floor El. +21 Room, Area, Emerqency Diesel Generator A Room SWEL Components: SWELl -095, 096 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YZ NEJ U[D N/AL]

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of YZ N-] U[-- N/AD--

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YZ NO UD N/AZ raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 767 of1014 Page 176 of 210 Sheet 2 of 4 Status: Y[ Nn-- Ut-l Area Walk-By Checklist (AWC) AWC-045 Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator A Room

4. Does it appear that the area is free of potentially adverse seismic YZ NI[Z UI-- N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YE NEIl uJ- N/ADI interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YN NDI U-- N/ADI interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YN ND ULIE N/AD1 interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 768 of'1014 Page 177 of 210 Sheet 3 of 4 Status: Y[ N-I UD Area Walk-By Checklist (AWC) AWC-045 Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator A Room

8. Have you looked for and found no other seismic conditions that could YE NEil UL-adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Housekeeping issue; no seismic concern o Gloves left in area Evaluated by: Natalie George Date: 10/8/12 Chu-Chieh Lin .
  • 10/8/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 769 ofl 014 Page 178 of 210 Sheet 4 of 4 Status: YN NEI- U]-I Area Walk-By Checklist (AWC) AWC-045 Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator A Room SWEL Components: SWEL1-095. 096 Photographs Note: Cover not secure on north side of emergency diesel generator

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 770 of 1014 Page 179 of 210 Sheet 1 of 4 Status: Y[ ND U-II Area Walk-By Checklist (AWC) AWC-046 Location: Bldg. FHB Floor El. +1 Room, Area' Multiplexer Enclosure West Side SWEL Components: SWEL2-017, 018, 019 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NDl UL- N/AL]-

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of YZ NE-] U[] N/A[D]

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit YN] ND: UD-- N/AD-raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 771 of1014 Page 180 of 210 Sheet 2 of 4 Status: Y[. NI- UI]

Area Walk-By Checklist (AWC) AWC-046 Location: Bldg. FHB Floor El. +1 Room, Area Multiplexer Enclosure West Side

4. Does it appear that the area is free of potentially adverse seismic YN NE] UDI N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YN NDI UD- N/ADI interactions that could cause flooding or spray in the area?

Pipe from CCW tank should have been previously analyzed for seismic event; no seismic concern

6. Does it appear that the area is free of potentially adverse seismic YN N[I- U[I N/A[]

interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic YN Nil ULI N/A--

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 772 of1014 Page 181 of 210 Sheet 3 of 4 Status: YE NEI Ur-Area Walk-By Checklist (AWC) AWC-046 Location: Bldg. FHB Floor El. +1 Room, Area Multinlexer Enclosure West Side

8. Have you looked for and found no other seismic conditions that could YZ N[:]UID adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

  • Several valves are leaking oil (CC MVAAA617, CC MVAAA618, and CC MVAAA622), no seismic concern; WR 288397 initiated for CC MVAAA617, WR288398 initiated for CC MVAAA618, and WR 288399 initiated for CC MVAAA622 Evaluated by: Natalie George Date: 10/10/12 Chu-Chieh Lin 10/10/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 773 of1014 Page 182 of 210 Sheet 4 of 4 Status: Y[ NEI U-I Area Walk-By Checklist (AWC) AWC-046 Location: Bldg. FHB Floor El. +1 Room, Area Multiplexer Enclosure West Side SWEL Components: SWEL2-017, 018, 019 Photographs Note: Fluorescent lights do not have cages. Note: Example of valve leaking oil Falling bulbs will not damage equipment and is not a seismic concern.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 774 of1014 Page 183 of 210 Sheet I of 4 Status: Y[ NEI UD Area Walk-By Checklist (AWC) AWC-047 Location: Bldg. FHB Floor El. +1 Room, Area, Fuel Pool Heat Exchanger Room SWEL Components: SWEL2-020 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NDl U[- N/AD potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

. Conduits and pipe supports well anchored

2. Does anchorage of equipment in the area appear to be free of YO ND UD- N/A[-1 significant degraded conditions?

. No corrosion found

3. Based on a visual inspection from the floor, do the cable/conduit YE] ND-] UDl N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 775 of1014 Page 184 of 210 Sheet 2 of 4 Status: YN NFD U[--

Area Walk-By Checklist (AWC) AWC-047 Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Heat Exchanqer Room

4. Does it appear that the area is free of potentially adverse seismic YZ N[-- UL N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic Y[ NDI UD-] N/A[D interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YE NDI UEI N/ADI interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic Y[ NDI U[ N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 776 ofl1014 Page 185 of 210 Sheet 3 of 4 Status: YM Nn UL-n Area Walk-By Checklist (AWC) AWC-047 Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Heat Exchanqer Room

8. Have you looked for and found no other seismic conditions that could YI N[I ULI--

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-10-2012 Dinesh Patel 10-10-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 777 of1014 Page 186 of 210 Sheet 4 of 4 Status: YN Nj- Ur-Area Walk-By Checklist (AWC) AWC-047 Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Heat Exchanger Room SWEL Components: SWEL2-020 Photographs Note: Example of pipe support in good condition.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 778 of1014 Page 187 of 210 Sheet I of 4 Status: Y[ NEI UD-Area Walk-By Checklist (AWC) AWC-048 Location: Bldg. FHB Floor El. +1 Room, Area, Fuel Pool Pump A Room SWEL Components: SWEL-2-012, 015 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YN NEI UD- N/AD--

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of YZ NEI UD] N/AD-significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit Y] N[: UD-- N/AD]

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 779 of1014 Page 188 of 210 Sheet 2 of 4 Status: Y[ NEI U[--

Area Walk-By Checklist (AWC) AWC-048 Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump A Room

4. Does it appear that the area is free of potentially adverse seismic YE NEI UIE N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YE N[D] UiE N/AD-]

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic YE NDI UE- N/ADI interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YE ND: UE- N/AD-]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 780 of1014 Page 189 of 210 Sheet 3 of 4 Status: YI* ND- UD--

(AWC) AWC-048 Area Walk-By Checklist Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump A Room

8. Have you looked for and found no other seismic conditions that could Y[ N[-] U--

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Natalie Georae Date: 10/10/12 Chu-Chieh Lin 10/10/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 781 of1014 Page 190 of 210 Sheet 4 of 4 Status: YN NEI U-Area Walk-By Checklist (AWC) AWC-048 Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump A Room SWEL Components: SWEL2-012. 015 Photographs Note: Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 782 of1014 Page 191 of 210 Sheet 1 of 4 Status: YM ND UD--

Area Walk-By Checklist (AWC) AWC-049 Location: Bldg. FHB Floor El. +1 Room, Area' Fuel Pool Pump B Room SWEL Components: SWEL2-013, 016 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YO NDI UD-- N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YN NDI UD] N/AD significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YN NDI UD1 N/AD--

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 783 of1014 Page 192 of 210 Sheet 2 of 4 Status: YE NF] Ut]

Area Walk-By Checklist (AWC) AWC-049 Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump B Room

4. Does it appear that the area is free of potentially adverse seismic YE Nt] Ut] N/A[-]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

  • Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YE N[t] UtI N/AtI interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YE Nt:] Ut] N/At]

interactions that could cause a fire in the area?

7. Does it appear that the area is free of potentially adverse seismic YE N[-] Ut] N/At]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 784 of1014 Page 193 of 210 Sheet 3 of 4 Status: YE NI-- U--

Area Walk-By Checklist (AWC) AWC-049 Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump B Room

8. Have you looked for and found no other seismic conditions that could YE NEI IF adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Natalie George Date: 10/12/12 Chu-Chieh Lin 10/12/12

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 785 of'1014 Page 194 of 210 Sheet 4 of 4 Status: YM NEI U-Area Walk-By Checklist (AWC) AWC-049 Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump B Room SWEL Components: SWEL2-013, 016 Photographs Note: t-uei rooi rump s IKoom

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 786 of1014 Page 195 of 210 Sheet I of 4 Status: YZ NrI UDl Area Walk-By Checklist (AWC) AWC-050 Location: Bldg. FHB Floor El. -35 Room, Area' Refuel Canal Drain Pump Area SWEL Components: SWEL2-014. 022. 023. 024. 025. 026 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Y[K NO] L[-I N/AF]

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

  • All anchorage in area is in good condition
2. Does anchorage of equipment in the area appear to be free of YE N[I U-- N/A-]

significant degraded conditions?

  • No degraded conditions were found on any anchorage
3. Based on a visual inspection from the floor, do the cable/conduit YN NEI U[-I N/A--

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 787 of1014 Page 196 of 210 Sheet 2 of 4 Status: Y] NFI U-I Area Walk-By Checklist (AWC) AWC-050 Location: Bldg. FHB Floor El. -35 Room, Area Refuel Can al Drain Pump Area

4. Does it appear that the area is free of potentially adverse seismic Y[ NO UIO N/A[D]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

  • Overhead lights with no covers present. No seismically sensitive equipment in vicinity; no seismic concern.
5. Does it appear that the area is free of potentially adverse seismic YO ND U[-i N/AD--

interactions that could cause flooding or spray in the area?

6. Does it appear that the area is free of potentially adverse seismic YE ND U[D N/ADl interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YE ND UD N/AD--

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 788 of'1014 Page 197 of 210 Sheet 3 of 4 Status: YZ No U[--

Area Walk-By Checklist (AWC) AWC-050 Location: Bldg. FHB Floor El. -35 Room, Area Refuel Canal Drain Pump Area

8. Have you looked for and found no other seismic conditions that could YZ NE] U-I adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-10-2012 Dinesh Patel 10-10-2012

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 789 of1014 Page 198 of 210 Sheet 4 of 4 Status: Y[* Nil UL-I (AWC) AWC-050 Area Walk-By Checklist Location: Bldg. FHB Floor El. -35 Room, Area Refuel Canal Drain Pump Area SWEL Components: SWEL2-014. 022. 023, 024. 025. 026 Photographs Note: All overhead equipment is properly secured.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 790 of1014 Page 199 of 210 Sheet 1 of 4 Status: YE ND- UD-Area Walk-By Checklist (AWC) AWC-051 Location: Bldg. FHB Floor El. -35 Room, Area, Back-Up Fuel Pool Heat Exchanger Room SWEL Components: SWEL2-021 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YE ND U-I N/AD1 potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
  • Conduits and pipe supports well anchored
2. Does anchorage of equipment in the area appear to be free of YN NDI UD N/AD significant degraded conditions?
  • No corrosion or any other degraded condition were found on anchorage
3. Based on a visual inspection from the floor, do the cable/conduit Y[K ND_ UD N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

'If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 791 of1014 Page 200 of 210 Sheet 2 of 4 Status: YEE NDI UD-Area Walk-By Checklist (AWC) AWC-051 Location: Bldg. FHB Floor El. -35 Room, Area Back-Up Fuel Pool Heat Exchanger Room

4. Does it appear that the area is free of potentially adverse seismic YN NDJ U[-] N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic YN ND] UD- N/ADI interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YE ND- UD- N/AD interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YN NDI UD1 N/A[-]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 792 of1014 Page 201 of 210 Sheet 3 of 4 Status: YI* ND UDl AWC-051 Area Walk-By Checklist (AWC)

Location: Bldg. FHB Floor El. -35 Room, Area Back-Up Fuel Pool Heat Exchanger Room

8. Have you looked for and found no other seismic conditions that could Y[ N[:] UMI adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-10-2012 Dinesh Patel 10-10-2012

Engineering Report No. WF3-CS-12-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 793 of 1014 Page 202 of 210 Sheet 4 of 4 Status: YZ NF-I UM Area Walk-By Checklist (AWC) AWC-051 Location: Bldg. FHB Floor El. -35 Room, Area Back-Up Fuel Pool Heat Exchanger Room SWEL Components: SWEL-2-021 Photographs

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 794 of'1014 Page 203 of 210 Sheet 1 of 4 Status: YN ND UD Area Walk-By Checklist (AWC) AWC-052_

Location: Bldg. RAB Floor El. +35 Room, Area' Relay Room B SWEL Components: SWEL2-004 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Y[ NEI U[-i N/A--

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

0 Anchorage in area is in good condition.

2. Does anchorage of equipment in the area appear to be free of YN NDI U-- N/AD-]

significant degraded conditions?

0 No degraded conditions were observed.

3. Based on a visual inspection from the floor, do the cable/conduit YE ND UD- N/A[-]

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3FI-2013-0024 Rev. 0 Page 795 ofIO14 Page 204 of 210 Sheet 2 of 4 Status: Y[ NDI U-Area Walk-By Checklist (AWC) AWC-052 Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

4. Does it appear that the area is free of potentially adverse seismic YDI NO U[-Z N/A[D]

spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

5. Does it appear that the area is free of potentially adverse seismic Y[ NDI urO N/AD interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic Y[ NDI U[- N/AD interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YE NEI U[D N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-1 2-00003 Attachment D Enclosure to W3F1-2013-0024 Rev. 0 Page 796 of1014 Page 205 of 210 Sheet 3 of 4 Status: YI* NI-U-Iu--

AWC-052 Area Walk-By Checklist (AWC)

Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

8. Have you looked for and found no other seismic conditions that could YX Ni] U-I adversely affect the safety functions of the equipment in the area?

" Possible surface cracks can be seen in the floor. Most have been filled. These cracks do not pose seismic concerns.

  • Blocks walls located around the room are acceptable per drawing no. G765 sh. 2, calculation no. Civil Seismic Block Walls, and FSAR Section 3.8.4.8 Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-10-2012 Dinesh Patel 10-10-2012

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 797 of1014 Page 206 of 210 Sheet 4 of 4 Status: YN NEII UD Area Walk-By Checklist (AWC) AWC-052 Location: Bldg. RAB Floor El. +35 Room, Area RAB +35 SWEL Components: SWEL2-004 Photographs Note: Reinforced block wall Note: Possible surface cracks. Most have been filled

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 798 of'1014 Page 207 of 210 Sheet I of 4 Status: Y[ NR U-Area Walk-By Checklist (AWC) AWC-053_

Location: Bldg. RAB Floor El. +35 Room, Area, RAB +35 SWEL Components: SWEI-1-083. SWEL-2-005 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YZ N[I- U-- N/ADI potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of YZ N[-] U-- N/A[D]

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit Y[ N[-- U-- N/AD-raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 799 of1014 Page 208 of 210 Sheet 2 of 4 Status: YZ NM UD-Area Walk-By Checklist (AWC) AWC-053 Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

4. Does it appear that the area is free of potentially adverse seismic YN NEI U[I N/ADI spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

. Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

5. Does it appear that the area is free of potentially adverse seismic Y[ ND-] UD-- N/ADI interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic YN ND-- U[:] N/AO-interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic YN N-- ULI N/A[-]

interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 800 of1014 Page 209 of 210 Sheet 3 of 4 Status: YZ NEI UDl Area Walk-By Checklist (AWC) AWC-053 Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

8. Have you looked for and found no other seismic conditions that could YZ N[:]UF adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

" Operations appendix R supplies locker not anchored; will not interact with equipment if it falls.

Referred to Permit # RAB+35-10-488

  • Block wall near equipment acceptable per drawing no. G765 sh. 2, calculation no. Civil Seismic Block Walls, and FSAR Section 3.8.4.8 Evaluated by: Natalie George Date: 10/15/12 Chu-Chieh Lin 10/15/12

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment D W3F1-2013-0024 Rev. 0 Page 801 ofl 014 Page 210 of 210 Sheet 4 of 4 Status: YZ NE] U]I Area Walk-By Checklist (AWC) AWC-053 Location: Bldg. RAB Floor El. +35 Room, Area RAB +35 SWEL Components: SWELl-083. SWEL2-005 Photographs Note: Operations appendix R supplies locker

Engineering Report No. WF3-CS-12-0003 Enclosure to Attachment E W3F1-2013-0024 Revision 1 Page 802 of1O14 Page 1 of 10 Attachment E Potentially Adverse Seismic Conditions

-O*m CD co 07 Potentially Adverse Seismic Conditions Engineeing Repot No.WF3-CS-12-00003 a 0 Attachment E 0 Rev. 1 =6M Page 2 of10 AA LB # SWC/AWC # IDENTIFIED CONDITION UCENSING I BASIS EVALUATION CONCLUSION ,=RESOLUTION STATUS 2 -. i.~. V4 -yr2. - & .

Condition meets the Licensing Basis.

L8-O1 AWC-001 An anchor bolt on SISR-883 is missing (1 of 4). Calculation SISR883 shows that only 3 bolts are N/A N/A required on this baseplate.

Condition meets the Licensing Basis.

The bins are located away from the Emergency LB*-O2 AWC-a07 One contamination protection disposal bin is notFedarPupndohrsftretdSSsiNANA secured to the others. Feedwater Pump and other safety related SSCs in N/A N/A the room. The loose bin does not pose any seismic hazard and would not impact the safety related SSCs within the room.

Condition meets the Licensing Basis.

The base plate and support associated with it are LB-03 AWC-009 An anchor bolt is missing on pipe support CDRH4002. non-safety and non-seismic. Drawing 4305-11938 N/A N/A does not show the bolt detail and gives no information on the number of anchors. This is concluded to not be a seismic concern.

Initial Action: Initiate CR-WF3-2012-05729.

The following is a list of seismic concerns documented in AWC-O11: CR Suggested Action: Close CR to WRs 288661, 288662, and 288663.

  • Severe corrosion of tube steel supporting conduits Operability Review: EC-40681 has been approved which concludes that
  • Conduit 30819D-SB is corroded No Licensing Basis Evaluation was performed. the corrosion identified in this CR does not present any immediate N/A AWC-011
  • Struts supporting large bore pipes (below and Operability concern for the CCW System. The surface corrosion on CR-WF3-2012-05729 above) are corroded, support CCRR378 is only minor surface corrosion. The conduits identified steel member supporting SAngle overhead stairs initiated do not require the supports to be in place to meet the minimum span are corroded requirements for Operability. Support CCRR395 on line 3CC20-3B (CCW
  • Other mild corrosion was found throughout DRY TOWER B OUTLET TO CCW HT EXCH 8) has more than minor surface the area corrosion. With the current corrosion, Engineering has determined that there is adequate load margin for these two supports.

(0-n Potentially Adverse Seismic Conditions Engineering Repal No.WF3-CS 12-00003 0D 0 Attachment E Rev. 1 Page 3 of10 -x )

K)45 LB # SWC/AWC iii IDENTIFIED CONDITION LICENSING BASIS EVALUATION CONCLUSION .. . RESOLUTION .. - ' - STATS S1 ... . . ... . " ; 1 ." 4 , , .T." ,.

. . . . . . .4. A nJsim'~u The following is a list of adverse conditions identified Initial Action: Initiate CR-WF3-2012-04956.

in AWC-014: CR Suggested Action: Close CR to wgs 286031, 286033, 188404, 138259,

" Missing bolt on support near valve No Licensing Basis Evaluation was performed. 288034,eand 286035.

N/A AWC-014 CR-WF3-2012-04956 N SPMVAAA327 severely corroded This was entered directly into the CAP and a CR Initiated

  • Severe corrosion on base plate was initiated. Operability Review: No structural or seismic issues were found that could SSevere corrosionon base supplate wimpact safety related equipment. The amount and severity of the
  • Severe corrosion on pipe support corrosion found does not challenge the operation of the DCT/WCT Train B

Initial Action: Identified previously initiated Condition Report CR-WF3-2011-07679.

No Licensing Basis Evaluation was performed. CR Suggested Action: Replace flex conduit.

The conduit housing near valve SP MVAAA330 is severely corroded. This observed condition was already documented Operability Review: Examination of exposed cabling exiting the conduit CR-WF3-2011-07679 Initiated in the CAP with a CR. shows no sign of insulation degradation. There is also no indication of water contact with electrical conductors and no indication of a ground on any electrical buses. Visual inspection revealed no indication of water in the subject conduit.

Condition meets the Licensing Basis.

LB-04 AWC-014 Bolts missing on pump base plate. SQ-MN-198 specifies that four bolts are required N/A N/A for anchorage. Four bolts are installed on the base plate. Extra holes are present in the base plate.

CD _

0 N C Potentially Adverse Seismic Conditions Engineering Report No. WF3-CS-12-00003 MO OC)

CID0 Agachment E 0W Rev. 1 6 Page 4 of10 ,C.

LB# SWC/AWC # IDENTIFIED CONDITION . UCENSING BASIS EVALUATION CONCLUSION -.  ; ,ESOLUTION R ' " STATUS Initial Action: Initiated CR-WF3-2012-05172.

CR Immediate Action: Recommended that the enclosure be braced to surrounding steel or it be removed until an analysis can be done.

A temporary enclosure has been installed in the Operability Review: ECR 40448 states that: "Scaffold bars have now been Switchgear B Room. It has the potential to impact No Licensing Basis Evaluation was performed. securely attached to the structural angle members in the wall panels panels near it. The walls are bolted together, but there using scaffold clamps. These scaffold bars are attached with scaffold N/A AWC-018 are no anchors bolting the entosure to the floor. This was entered directly into the CAP, a CR was clamps to HVAC duct supports that happen to be adjacent to and above Closed There is only a 7" clearance from LCP-62 and one side initiated, and changes were immediately made in the enclosure. These braces are set in such a way that the enclosure will of the enclosure. thefield. not be able to move during a seismic event and strike any of the surrounding safety related equipment. This will ensure that the enclosure can be considered to be seismically restrained."

Therefore, the above described condition has been resolved and the temporary enclosure is not a seismic threat to any of the surrounding equipment.

Condition meets the Licensing Basis.

It is clear from photos of these unsecured barrels LB-O AWC030 Barrels near column 10A, line N are not properly that no Safety Related SSCs are within striking N/A N/A secured, range of the barrels if they were to fall over. Also, the barrels are light and have a low center of gravity making them unlikely to fall over, roll, and damage equipment in the area.

Initial Action: Initiated CR-WF3-2012-06472.

No Licensing Basis Evaluation was performed. CR Suggested Action: Close CR to WO 196829. CR-WF3-2a12-06472 N/A AWC-037 Trhere is severe corrosion on valve CHWMVAAA121A.CRW321-47 This was entered directly into the CAP and a CR Operability Review: Civil Design Engineering reports that none of this Initiated was initiated. corrosion is considered to be severe and none of the identified corrosion affects the operation or structural/seismic capacity of the valve.

(0: Ca CD o OD c,,

Potentially Adverse Seismic Conditions Engineering Report No. WF3-CS-12 00003 Attachment E CI0 Rev. 1 60 Page 5 of 10 --.

4* NC))*

".C, LB # SWC/AWC # IDENTIFIED CONDITION ICENSING BASIS EVALUATION CONCLUSION . . RELUTION . STATUS Initial Action: Initiated CR-WF3-2012-05372.

N/A AWC-037 Severe corrosion was found onNo Licensing Basis Evaluation was performed. CR Suggested Action: Close CRto WRs 287812 and 287813. CR-WF3-2012-05372 and CHWMVAAA127B. This was entered directly into the CAP and a CR Operability Review:, Civil Design Engineering reports that none of this Initiated was initiated, corrosion is considered to be severe. None of the identified corrosion affects the operation of the identified valves.

Initial Action: Identified existing Condition Report CR-WF3-2012-05089.

CR Suggested Action: Close CR to WRs 286898 and 286900.

Operability Review: CHWMVAAA436 and CHWMVAAA881 are 4 inch (normally locked open) manually operated butterfly valves which have a No Licensing Basis Evaluation was performed. passive safety function of being open to ensure Chilled Water flow to N/A AWC-037 Severe corrosion and leakage on valves essential air handling units. These valves are not containment isolation CR-WF3-2012-05089 CHWMVAAA436 and CHWMVAAA881 This observed condition was already documented valves. These valves can be closed to isolate the supply header for system Initiated in the CAP with a CR. maintenance, but serve no safety function in the closed position in a post-accident situation.

EC Reply 40355 addresses that with the amount of corrosion identified, the structural integrity of the gland follower bolts and nuts is such that there is no challenge to the pressure boundary based on the amount of material remaining.

Condition meets the Licensing Basis.

the only equipment that the chain could impact is LB-06 AWC-037 A chain from a crane has the potential to interact with panel PMCIMUXRA4601. This is a non-safety and N/A N/A non-seismic panel. After reevaluation, it was determined that the piping could not be impacted from the chain.

CD _-

Potentially Adverse Seismic Conditions Engineering Repor No.WF3-CS-12-00003 Attachment E 0

-- 0)

Rev. 1 A A Page 6 of 10 LB # SWC/AWC #

  • ,... . ... IDENTIFIED CONDITION

... = ,* * ** , , UCENSING LI-".

J , ... BASIS

, EVALUATION 4A <'SC.

.e1VI e,. CONCLUSION  :. .,

, , .: ,...C.i/:*

.. . . RESOLUTION

CR Suggested Action: Close CR to WR 287650.

There is degradation of the concrete pad near No Licensing Basis Evaluation was performed.

embedded plates to which the legs of tank NG-MACC- Operability Review: The loose grout underneath NG MACC005 is from -WF3-2012-027 N/A AWC-041 005 are welded, and there are cracks in concrete near This was entered directly into the CAP and a CR around the embed plates to which the tank is welded. This loose grout Initiated embedded plates to which the legs of tank NG-MACC- does not affect the seismic or structural capacity of these embedded 006 are welded. was initiated. plates since they are held into the concrete with cast-in-place anchors.

The embed plate details are shown on drawing G663 at coordinate D14 on the drawing. This loose grout is treated as a cosmetic coating for the pad.

Initial Action: Initiate CR-WF3-2012-O5203.

CR Suggested Action: Close CR to WR 287462.

No Licensing Basis Evaluation was performed. Operability Review: These conduit supports are not safety-related, are not There is severe corrosion on the support for conduit CR-WF3-20112-05203 N/A AWC-041 lines 320950 NB and 3209SF-NB. This was entered directly into the CAP and a CRthe subject of any Technical Specifications or the Technical Requirements Initiated iwas initered. dManual, and do not perform a necessary support function for the purpose of ensuring accident prevention/mitigation, safe plant shutdown or reactor coolant pressure boundary integrity. This condition report describes a condition of a Structure, System or Component (SSC) that is not within the scope of the Operability Determination Process.

Initial Action: Initiate CR-WF3-2012-05743.

CR Suggested Action: Add a step to Task 07 of WO 290744 to reinstall No Licensing Basis Evaluation was performed. light switch to MCC 3158 weather endosure.

N/A SWELl-003 Light switch inside weather enclosure is not secured. Operability Review: CCW/ACCW Train B is currently out of service per CR-WF3-2012-05743 EOS 12-0433. The plant is currently in MODE 6. Although work on MCC- Initiated was initiated. 3158 is not yet completed and CCW/ACCW Train B is out of service, the condition identified in this CR does not affect the operation of any of the breakers in MCC-315B and does not affect the Operability of CCW/ACCW Train B.

tZ m 0 C' Potentially Adverse Seismic Conditions Engineering Report No. WF3-CS-12-00003 Attachment E Rev. 1 S60 DC:

Page 7 of 10 LB# SWC/AWC# . IDENTIFIED CONDITION UCENSING LI BASIS,,-EVALUATION -CONCLUSION

  • .*, . * *i.,...?,, -. . ... -. . - ., R.E-gLUTIpN ..-..

.,c*."". .... ,ASTATUS ,

__._.___.__ _ _ _ _ _ _ __ _ _ _ _ _ _ .1. .:. -,. . w e .4-* - - .1 Initial Action: Initiate CR-WF3-2012-04905 No Licensing Basis Evaluation was performed. CR Suggested Action: Implement WR 285749.

N/A SWELl-020 Bolts do not have sufficient thread interaction (nuts are CR-WF3-2012-04905 also missing) on plate that connects solenoid to valve. This was entered directly into the CAP and a CR Operability Review: EC40135 documents the seismic qualification of the Initiated was initiated. solenoid mounting plate is not affected by the current configuration. It also documents the corrosion is not severe enough to cause any structural concerns.

Condition meets the Licensing Basis.

Anchors are cast-in-place, not wedge anchors.

LB-07 SWEL1-064 Cracks found near several anchors. The cracks in the surface appear to be cracksN/A associated with either a surface patch after placement or a grout pad poured under the equipment once it was set in place. This grout will be bearing only.

Initial Action: Initiate CR-WF3-2012-05698.

CR Suggested Action: Tighten nut fully down on the baseplate using proper plant procedure.

Operability Review: The seismic qualification of this heat exchanger is No Licensing Basis Evaluation was performed. shown in SQRT file SQ-NSSS-PE-S6. The analysis for the anchors is on pdf pages 57 and 58 of the SQRT File. The tensile stress in the bolts on this CR-WF3-2012-05698 N/A SWEL2-021 One of the four 3/4" diameter anchor bolts is loose, end of the heat exchanger is 32,357 psi. The shear stress is 6491 psi. The Initiated This was entered directly into the CAP and a CR allowable tensile stress is 43,316 psi. Even with the gap under the nut on was initiated, one of the anchors, the shear will still be carried by all four of the bolts on this end of the heat exchanger. The tensile load will begin to be carried by the three fully tightened nuts, but the one with the gap will begin to take the tensile load as the other three begin to stretch with the load.

Based on EC40666, there is no operability impact to the Spent Fuel Pool or the Spent Fuel Pool Cooling System.

Condition meets the Licensing Basis.

wo conduits were found to be -1/4" from the west end of LB-08 SWELI-002 SDEMCC31 lB. It was determined that the MCC will not move N/A N/A enough to strike the conduits so there is no interaction concern. This is documented in the SWC for SWEL1-002.

CD Co Potentially Adverse Seismic Conditions Engineering Report No WF3-CS-12-00003 0 Attachment E 0 Rev. 1 00 Page 8 of 10 C:)

LBU SWC/AWC# IDENTIFIED CONDITIONL UCENSING BASIS EVALUATION CONCLUSION. RESOLUTION r STATUS

.. ';A".

  • Ct ,.A C -Oe. -
  • ,A j ,-.".

'.-' . . ,.* ~ . ' . _ _ _. _ __...

Drawing 1564-9155 indicates that there should be six bolts used to hold down panel ICICDC1-C to the structural steel. SQRT File SQ-IC-61 indicates that there should be eight hold-down bolts. Inreality, there are seven hold-down bolts. Initial Action: Initiate CR-WF3-2012-07132 Conduits 39752-NA and 36323-NA and an electrical plug CR Suggested Action: Change design documents to reflect correct are loose. No Licensing Basis Evaluation was performed. number of bolts. Tighten fittings for conduits and electrical plug. Install N/A SWELl-075 IC ITS3001 C2 IBISSW inside of the cabinet is missing a nut on bracket of instrument inside panel. Replace nuts and/or screws on CR-WF3-2012-07132 nut from the hold-down bracketN /his instrument is This Awas directly into the CAP and a CR entered covers in lower part of cabinet. Initiated was initiated.

noted in Asset Suite as being "Abandoned in place per Operability Review: EC 41374 provided justification to Operations to DC-3382". document that these conditions do not adversely affect the panel.

A cover for an electrical panel on the lower left inside of the cabinet is missing one of four screws.

A cover on the lower right inside of this cabinet is missing a nut from one of the four screws.

Lead shielding was found to be adjacent to and touching SG ILTl11SA (STEAM GENERATOR 1 LEVELIXMITR (WIDE RANGE)). The EC and TSR restricted the location of this shielding so it could not fall over and hit any safety related equipment. Contrary to this, the shielding was Initial Action: Initiate CR-WF3-2012-07217.

found to be less than 1"from the SG ILT1loSA instrument, and was touching the support, tubing, and No Licensing Basis Evaluation was performed. CR Suggested Action: Remove shielding from near instrument. CR-WF3-2012fl7217 N/A SWEL1-079 valves for the instrument. This was entered directly into the CAP and a CR Initiated.

was nititedOperability Review: The instrument was not required by Tech Specs This was discussed with the ALARA group upon exit from was initiated, while the shielding was installed, so there was no impact on operability. 1 Containment. ALARA said that the shielding was not Shielding removed prior to instrument being required for service.

installed in this location when put in place in late October. Apparently the shielding had been moved by unknown personnel. To resolve this problem, ALARA removed this shielding from containment.

CID 0 EDt (.n) oc, :

Potentially Adverse Seismic Conditions Engineeing Report No.WF3-CS-12-00003 -, ' CD Attachment E Rev. I Page 9 of 10 LB# SWC/AWC# IDENTIFIED CONDITION . LICENSING BASIS EVALUATION CONCLUSION ,. .7.. RESOLUTIQN . .. STATUS In the cubicle for SSDEBKR3B 7 CKTBRK, there is a missing screw in an upper plate. This plate is restrained by other screws and is held in place. There is no observable sagging or movement on the plate and the Initial Action: Initiated CR-WF3-2012-06179 and CR-WF3-2012-06634.

plate cannot come loose and strike any other equipment inside panel. No other equipment is supported from this CR Suggested Action: Replace missing screws on upper plates in cubicles plate. This screw should be reinstalled. Initiated WR 7 and 11. Replace missing machine bolt on relay panel in cubicle 14A.

289665.

No Licensing Basis Evaluation was performed. Operability Review: The missing screws in cubicles 7 and 11 do not affect CR-WF3-2012-06179 In the cubicle for 4KVEBKR3B 11 CKTBRK, there is a the subject plates since they are held in place with other screws and will and N/A SWEL1-097 loose screw on an upper plate. This plate is restrained This was entered directly into the CAP and a CR not come loose during normal operations or during a seismic event. CR-WF3-2012-06634 by other screws and is held in place. There is no Initiated observable sagging or movement on the plate and the The relay panel in cubicle 14A is being held in place with one machine plate cannot come loose and strike any other equipment bolt, clips on one side of the panel, and a hinge on the other side. This inside panel. No other equipment is supported from this will adequately restrain the hinged panel in place. In addition, the relay plate. This screw should be tightened in place. Initiated on this panel is an alarm relay. Therefore, contact chatter on the relay WR 289666. will not be a concern for affecting the automatic start or stop of other equipment.

In the cubicle for RFREBKR3B 14A CKTBRK, the relay panel was found to have only one of two machine bolts installed to hold the plate in place.

Initial Action: Initiated CR-WF3-2012-06445.

Snubber CHSR237 was removed from line 2CH2-S3A/B in No Licensing Basis Evaluation was performed. CR Suggested Action: Remove strut from plant. (The strut was removed 1986. While performing this area walk-by, it was found by work order 333109.) CR-WF3-2012-06445 N/A AWC-031 tha part that of the part of the strut strforfor CH-SR237 CHSRea waswask-ti, inwas still in place. This was entered directly into the CAP and a CR Initiated was initiated. Operability Review: EC41379 documented that the loose end of this strut could not strike any nearby equipment. Therefore, there was no impact on any other equipment.

Initial Action: Initiated CR-WF3-2012-07129.

No Licensing Basis Evaluation was performed.

N/A AWC-057 The beam under line 2RC1-176 for spring hanger RCSH- CR Suggested Action: Straighten beam under line. CR-WF3-2012-07129 4162 was found off-center. This was entered directly into the CAP and a CR Initiated was initiated. Operability Review: ECs 41521 and 41649 documented that the support was acceptable in the as-found condition.

CD _

55 Potentially Adverse Seismic Conditions Engineeing Repor No.WF3-CS-12-00003 Attachment E Rev. 1 oCD 0)

Page 10Of10 0P.

LB# SWC/AWCN IDENTIFIED CONDITION .... LUCENSING BASIS EVALUATION CONCLUSION J"-; .. .. ,

... .RESOLUTION . "".. STATUS

',.,_____"____'__-._______________._._.._________-_*. ,-t:&.*.*.- "*.. *.............- . .. , .. *. .*..:..*.*...% .. -. , ,_-_._*;.______.__,,

Initial Action: Initiated CR-WF3-2012-07680 for the corrosion on line 3CC 1-1/2-35-B2.

Line 3CC1 1/2-35-B2 was found to have what could be No Licensing Basis Evaluation was performed. CR Suggested Action: Recoat line 3CC1-1/2-35-B2. Evaluate line to CR-WF3-2012-07680 N/A AWC-062 significant Pump corrosion 2B shroud where it +16 at elevation exits 7-1/8".

the Reactor Coolant This was entered directly into the CAP and a CRIntaedetermine if section needs to be replaced due to minimum wall thickness. Initiated was initiated.

Operability Review: EC41699 documented that the 1 pipe wall thickness exceeds the minimum wall thickness. Therefore, the line is acceptable as-is.

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment F W3F1-2013-0024 Rev. 0 Page 812 of1014 Page 1 of 8 Attachment F Licensina Basis Evaluation Forms (Revision 0)

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment F W3F1-2013-0024 Rev. 0 Page 813 of1014 Page 2 of 8 Licensing Basis (LB) Evaluation Form LB Evaluation No. LB-01 Originating SWC/AWC AWC-001 Equipment ID No. SISR-883 Equip. Class N/A Equipment Description Pipe Support Location: Bldg. RAB Floor El. -35 Room, Area Safeguards Room B Condition On pipe support SISR-883, one of the four anchor bolts was found to be missing.

Documents Reviewed Calculation SISR883 Licensing Basis Anchor bolts and base plate stresses shall be within allowable limits.

Evaluation Review of calculation SISR883 shows that only 3 anchor bolts are required for this base plate.

Conclusion Condition Meets the Licensing Basis: M Yes D] No Prepared by: Dinesh Patel Date 10-27-2012 Licensing Basis Reviewer Reviewed by: Greg Fergquson Date 11-10-2012 Peer Reviewer

Engineering Report No. WF3-CS-12-00003 Attachment F Enclosure to W3F1-2013-0024 Rev. 0 Page 814 of1014 Page 3 of 8 Licensing Basis (LB) Evaluation Form LB Evaluation No. LB-02 Originating SWC/AWC AWC-007 Equipment ID No. N/A Equip. Class N/A Equipment Description Contamination Protection Disposal Bins Location: Bldg. RAB Floor El. -35 Room, Area Emerqency Feedwater Pump Area Condition A series of contamination protection disposal bins has one of five bins loose and not secured to other bins.

Documents Reviewed N/A Licensing Basis Loose items may not interact with Safety Related SSCs.

Evaluation The bins are located away from the Emergency Feedwater Pump and other safety related SSCs in the room. The loose bin does not pose any seismic hazard and would not impact the safety related SSCs within the room.

Conclusion Condition Meets the Licensing Basis: Z Yes R- No Prepared by: Dinesh Patel Date 10-27-2012 Licensing Basis Reviewer Reviewed by: Greq Ferguson Date 11-10-2012 Peer Reviewer

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment F W3F1-2013-0024 Rev. 0 Page 815 of1014 Page 4 of 8 Licensing Basis (LB) Evaluation Form LB Evaluation No. LB-03 Originating SWC/AWC AWC-009 Equipment ID No. CDRH4002 Equip. Class N/A Equipment Description Pipe Support Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Condition Pipe support CDRH4002 has one of its four anchor bolts missing.

Documents Reviewed Drawing 4305-11938 Licensing Basis Anchor bolts and base plate stresses shall be within allowable limits.

Evaluation The base plate and support associated with it are non-safety and non-seismic. Drawing 4305-11938 does not show the bolt detail, and gives no information on the number of anchors. This is concluded to not be a seismic concern.

Conclusion Condition Meets the Licensing Basis: Z Yes -- No Prepared by: Dinesh Patel Date 10-27-2012 Licensing Basis Reviewer Reviewed by: Greg Ferguson Date 11-10-2012 Peer Reviewer

Engineering Report No. WF3-CS-1 2-00003 Enclosure to Attachment F W3F1-2013-0024 Rev. 0 Page 816 of1014 Page 5 of 8 Licensing Basis (LB) Evaluation Form LB Evaluation No. LB-04 Originating SWC/AWC AWC-014 Equipment ID No. SP MPMPOO14 A and SP MPMPOO14 B Equip,. Class N/A Equipment Description Sump Pump Location: Bldg. RAB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Condition An anchor bolt was found missing on a sump pump cover base plate.

Documents Reviewed SQ-MN-198 Licensing Basis Anchor bolts and base plate stresses shall be within allowable limits.

Evaluation Review of SQ-MN-1 98 indicates that only four anchor bolts are required for anchoring the sump cover plate. Presently four anchor bolts are installed. This indicates that the sump pump cover plate has extra holes drilled into the plate. No anchor bolts are missing, and this meets the Licensing Basis.

Conclusion Condition Meets the Licensing Basis: N Yes nI- No Prepared by: Dinesh Patel Date 10-27-2012 Licensing Basis Reviewer Reviewed by: Greg Ferguson Date 11-14-2012 Peer Reviewer

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment F W3F1-2013-0024 Rev. 0 Page 817 of1014 Page 6 of 8 Licensing Basis (LB) Evaluation Form LB Evaluation No. LB-05 Originating SWC/AWC AWC-030 Equipment ID No. N/A Equip. Class N/A Equipment Description Disposal Barrels Location: Bldg. RB Floor El. -4 Room, Area Col. 10A. Line N Condition Disposal/Storage barrels are not secured to each other.

Documents Reviewed N/A Licensing Basis Loose items may not interact with Safety Related SSCs.

Evaluation It is clear from photos of these unsecured barrels that no Safety Related SSCs are within striking range of the barrels if they were to fall over. Also, the barrels are light and have a low center of gravity making them unlikely to fall over, roll, and damage equipment in the area.

This condition meets the Licensing Basis.

Conclusion Condition Meets the Licensing Basis: [K Yes I No Prepared by:. Brian Pace Date 11-14-2012 Licensing Basis Reviewer Reviewed by: Greg Ferguson Date 11-14-2012 Peer Reviewer

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment F W3F1-2013-0024 Rev. 0 Page 818 oflO14 Page 7 of 8 Licensing Basis (LB) Evaluation Form LB Evaluation No. LB-06 Originating SWC/AWC AWC-037 Equipment ID No. N/A Equip. Class N/A Equipment Description Hanging Chain from Crane Location: Bldg. RAB Floor El. +46 Room, Area Northwest RAB +46 Area Condition A chain hanging from a crane in the room has the potential to impact nearby panels and piping.

Documents Reviewed Asset Suite Equipment Database Licensing Basis Loose items may not interact with Safety Related SSCs.

Evaluation The chain for the overhead chainfall cannot strike or cause damage to any equipment that is safety related. The panel, PMCIMUXRA4601, that is nearby is non-safety and non-seismic according to Asset Suite. After reevaluation, it was determined that the piping and valves nearby are higher than the main mass of the chain making it doubtful the chain could damage the equipment.

Conclusion Condition Meets the Licensing Basis: N Yes D No Prepared by: Brian Pace Date 11-07-2012 Licensing Basis Reviewer Reviewed by: Greg Ferguson Date 11-10-2012 Peer Reviewer

Engineering Report No. WF3-CS-12-00003 Enclosure to Attachment F W3F1-2013-0024 Rev. 0 Page 819 of'1014 Page 8 of 8 Licensing Basis (LB) Evaluation Form LB Evaluation No. LB-07 Originating SWC/AWC SWELl-064 Equipment ID No. HVCMAHU0009-A Equip. Class Air Handlers Equipment Description Control Room Emergency Filtration Unit A Location: Bldg. RAB Floor El. +46 Room, Area Room 314, Col. 9A. Line K Condition Cracks found near several anchors (adverse condition for Question #4).

Documents Reviewed IPEEE Seismic Report page E-76 Licensing Basis Anchor bolts and base plate stresses shall be within allowable limits Evaluation On page E-76 of the IPEEE Seismic Report, it states that the unit has twelve 7/8" diameter cast in place bolts. The cracks in the surface appear to be cracks associated with either a surface patch after placement or a grout pad poured under the equipment once it was set in place. This grout will be bearing only. Therefore, this meets the licensing basis.

Conclusion Condition Meets the Licensing Basis: Z Yes --I No Prepared by:. Brian Pace Date 10-29-2012 Licensing Basis Reviewer Reviewed by: Greg Ferguson Date 11-10-2012 Peer Reviewer