ULNRC-06463, Registration of Dry Spent Storage Canister HGMPC0030
| ML18298A330 | |
| Person / Time | |
|---|---|
| Site: | Callaway, HI-STORM 100 |
| Issue date: | 10/25/2018 |
| From: | Wink R Ameren Missouri, Union Electric Co |
| To: | Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation |
| References | |
| ULNRC-06463 | |
| Download: ML18298A330 (4) | |
Text
Ameren MISSOURI Callaway Plant October25, 2018 ULNRC-06463 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-000 1 1 OCFR72.2 1 2(b)(2)
Ladies and Gentlemen:
DOCKET NUMBERS 50-483 AND 72-1045 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.
RENEWED FACILITY OPERATING LICENSE NPF-30 INDEPENDENT SPENT FUEL STORAGE INSTALLATION REGISTRATION OF DRY SPENT FUEL STORAGE CANISTER HGMPCOO3O Pursuant to 10 CFR 72.212(b)(2), Union Electric Company cl/b/a Ameren Missouri, the Licensee for Callaway Plant, is registering the use of a dry spent fuel storage cask to store spent fuel under a 10 CFR Part 72 general license at the Callaway Plant Independent Spent Fuel Storage Installation (ISFSI). The information below is provided for multi-purpose canister (MPC) number HGMPCOO3O, used to store spent fuel within cavity enclosure container (CEC) number HGUMAXOO3O, beginning on October 19, 2018.
The following information is provided as required by 10 CFR 72.2 12(b)(2):
Licensee Name:
Union Electric Company Licensee Address:
Callaway Nuclear Plant 83 1 5 County Road 459 Steedman, MO 65077 Reactor License No:
NPF-30 Docket Nos.:
50-483 and 72-1045 (1SFSI)
Contact Name and
Title:
Tom Elwood, Supervising Engineer, Regulatory Affairs and Licensing 8315 County Road 459 Steedman, MO 65077 AmerenMissouricom
ULNRC-06463 October25, 201$
Page 2 of 4 Cask Certificate No.:
Cask Model:
Certificate of Compliance No. 1 040, Amendment 0, April 6, 2015 HI-STORM UMAX Canister Storage System Cask Identification Nos. :
Multi-Purpose Canister (MPC) Identification No. : HGMPCOO3O Cavity Enclosure Container (CEC) Identification No.:
HGUMAXOO3O This letter does not contain new commitments. Should you have questions regarding this submittal, please contact Mr. Tom Elwood, Supervising Engineer, Regulatory Affairs and Licensing, at 3 14-225-1905.
JLF Sincerely, Manager, Regulatory Affairs
ULNRC-06463 October 25, 2018 Page 3 of 4 cc:
Mr. Kriss M. Kennedy Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. L. John Klos Project Manager, Callaway Plant Office ofNuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop 09E3 Washington, DC 20555-0001 Director Division of Spent Fuel Management Office ofNuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-000 1
ULNRC-06463 October25, 2018 Page 4 of 4 Index and send hardcopy to QA file A160.0761 Hardcopy:
Certrec Corporation 6100 Western Place Suite 1050 Fort Worth, TX 76107 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)
Electronic distribution for the following can be made via Responses and Reports ULNRC Distribution:
F. M. Diya T. E. Herrmann B. L. Cox R. C. Wink T. B. Elwood S. A. Gaydos G. N. Klein C. 3. Ehmke Corporate Communications NSRB Secretary STARS Regulatory Affairs Mr. Jay Silberg (Pillsbury Winthrop Shaw Pittman LLP)