MONTHYEARULNRC-05690, Application for License Amendment Revision to Technical Specification 3.3.2 Function 6.g Engineered Safety Feature Actuation System (ESFAS) Instrumentation: on Trip of All Main Feedwater Pumps (LDCN 10-0011)2010-03-29029 March 2010 Application for License Amendment Revision to Technical Specification 3.3.2 Function 6.g Engineered Safety Feature Actuation System (ESFAS) Instrumentation: on Trip of All Main Feedwater Pumps (LDCN 10-0011) Project stage: Request ULNRC-05687, Application for Amendment to Technical Specification 3.3.2 Function 6.g Engineered Safety Feature Actuation System, Instrumentation: Auxiliary Feedwater Actuation on Trip of All Main Feedwater Pump (LDCN 10-0011)2010-03-29029 March 2010 Application for Amendment to Technical Specification 3.3.2 Function 6.g Engineered Safety Feature Actuation System, Instrumentation: Auxiliary Feedwater Actuation on Trip of All Main Feedwater Pump (LDCN 10-0011) Project stage: Request ML1009603372010-04-0606 April 2010 Acceptance Review Email, License Amendment Request (Exigent Circumstances), Revise Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation, for Function 6.G in TS Table 3.3.2-1 Project stage: Acceptance Review ML1009103222010-04-0707 April 2010 Exigent 14-day Individual Notice of Consideration of Issuance of Amendment, Revise Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation, for Function 6.g in TS Table 3.3.2-1 Project stage: Other ML1009103092010-04-0707 April 2010 Individual Notice of Consideration of Issuance of Amendment to Facility Operating License, Proposed No Significant Hazards Consideration Determination, and Opportunity for Hearing (Exigent Circumstances) (Tac No. ME3595) Project stage: Other NRC-2010-0151, Exigent 14-day Individual Notice of Consideration of Issuance of Amendment, Revise Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation, for Function 6.g in TS Table 3.3.2-12010-04-0707 April 2010 Exigent 14-day Individual Notice of Consideration of Issuance of Amendment, Revise Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation, for Function 6.g in TS Table 3.3.2-1 Project stage: Approval ML1010903012010-04-19019 April 2010 Email, Request for Additional Information License Amendment to Revise Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation, for Function 6.g in TS Table 3.3.2-1 Project stage: RAI ULNRC-05697, Revision to Technical Specification 3.3.2 Function 6.g Engineered Safety Feature Actuation System (ESFAS) Instrumentation Auxiliary Feedwater Actuation on Trip of All Main Feedwater Pumps2010-04-26026 April 2010 Revision to Technical Specification 3.3.2 Function 6.g Engineered Safety Feature Actuation System (ESFAS) Instrumentation Auxiliary Feedwater Actuation on Trip of All Main Feedwater Pumps Project stage: Other ML1011006652010-05-0505 May 2010 Amendment, Issuance of Amendment No. 196, Revise Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation, for Function 6.g in TS Table 3.3.2-1 (Exigent Circumstances) Project stage: Approval 2010-04-26
[Table View] |
|
---|
Category:Letter type:ULNRC
MONTHYEARULNRC-06853, Submittal of 2023 Fitness for Duty Performance Data Per Per 10 CFR 26.7172024-01-29029 January 2024 Submittal of 2023 Fitness for Duty Performance Data Per Per 10 CFR 26.717 ULNRC-06847, Supplement to Relief Request from Requirements of ASME BPV Code, Section XI, Subsection Iwl Regarding Examination and Testing of the Unbonded Post-Tensioning System (Relief Request C3R-01)2023-12-21021 December 2023 Supplement to Relief Request from Requirements of ASME BPV Code, Section XI, Subsection Iwl Regarding Examination and Testing of the Unbonded Post-Tensioning System (Relief Request C3R-01) ULNRC-06849, License Renewal Resolution for Commitments 34 and 35 Perform Evaluation of Crack Initiation and Propagation in Steam Generator Divider Plate and Tube-To-Tubesheet Welds2023-12-20020 December 2023 License Renewal Resolution for Commitments 34 and 35 Perform Evaluation of Crack Initiation and Propagation in Steam Generator Divider Plate and Tube-To-Tubesheet Welds ULNRC-06844, Request for Exemption from Specific Requirements in 2023 Security Rule, Enhanced Weapons, Firearms Background Checks, and Security Event Notification2023-12-0707 December 2023 Request for Exemption from Specific Requirements in 2023 Security Rule, Enhanced Weapons, Firearms Background Checks, and Security Event Notification ULNRC-06827, Supplement to License Amendment Request Regarding Support System Requirements for Residual Heat Removal and Control Room Air Conditioning Systems Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 (LDCN 22-0029)2023-11-20020 November 2023 Supplement to License Amendment Request Regarding Support System Requirements for Residual Heat Removal and Control Room Air Conditioning Systems Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 (LDCN 22-0029) ULNRC-06824, Response to Request for Additional Information Regarding Operating Quality Assurance Manual (Oqam) Revision 36A2023-08-17017 August 2023 Response to Request for Additional Information Regarding Operating Quality Assurance Manual (Oqam) Revision 36A ULNRC-06830, Transmittal of Updated Technical Specification Markup and Clean Pages for License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak2023-08-15015 August 2023 Transmittal of Updated Technical Specification Markup and Clean Pages for License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak ULNRC-06223, Minor Correction to License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test Frequencies (LDCN 2020-0004)2023-07-25025 July 2023 Minor Correction to License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test Frequencies (LDCN 2020-0004) ULNRC-06799, Submittal of Licensee Event Report 2022-003-01, Class 1E Electrical Air Conditioning System Thermal Expansion Valve Failure Resulted in Condition Prohibited by Technical Specifications2023-07-13013 July 2023 Submittal of Licensee Event Report 2022-003-01, Class 1E Electrical Air Conditioning System Thermal Expansion Valve Failure Resulted in Condition Prohibited by Technical Specifications ULNRC-06821, Post-Audit Follow-Up Information in Support of Callaway'S License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301)2023-06-21021 June 2023 Post-Audit Follow-Up Information in Support of Callaway'S License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301) ULNRC-06822, Additional Information Regarding Request for NRC Approval of Operating Quality Assurance Manual (Oqam) Revision 36a2023-06-14014 June 2023 Additional Information Regarding Request for NRC Approval of Operating Quality Assurance Manual (Oqam) Revision 36a ULNRC-06815, Request for NRC Approval of Operating Quality Assurance Manual, Revision 36a2023-06-0505 June 2023 Request for NRC Approval of Operating Quality Assurance Manual, Revision 36a ULNRC-06818, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate .2023-06-0505 June 2023 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate . ULNRC-06816, Withdrawal of Previously Submitted Enclosures Regarding License Amendment Request for Adoption of Alternative Source Term and Revision of Technical Specifications (LDCN 21-0015)2023-05-0909 May 2023 Withdrawal of Previously Submitted Enclosures Regarding License Amendment Request for Adoption of Alternative Source Term and Revision of Technical Specifications (LDCN 21-0015) ULNRC-06812, Submittal of 2022 Annual Radiological Environmental Operating Report2023-04-27027 April 2023 Submittal of 2022 Annual Radiological Environmental Operating Report ULNRC-06806, Submittal of Radiological Emergency Response Plan, Revision 552023-04-12012 April 2023 Submittal of Radiological Emergency Response Plan, Revision 55 ULNRC-06807, Submittal of Single Positive Test Forms2023-04-0303 April 2023 Submittal of Single Positive Test Forms ULNRC-06798, Submittal of Status of Plant Decommissioning Funding and ISFSI Decommissioning Funding Plan2023-03-30030 March 2023 Submittal of Status of Plant Decommissioning Funding and ISFSI Decommissioning Funding Plan ULNRC-06801, CFR 50.46 Annual Report Regarding ECCS Evaluation Model Revisions2023-03-30030 March 2023 CFR 50.46 Annual Report Regarding ECCS Evaluation Model Revisions ULNRC-06804, Submittal of Nuclear Property Insurance Reporting2023-03-29029 March 2023 Submittal of Nuclear Property Insurance Reporting ULNRC-06751, Application to Revise Technical Specifications to Adopt TSTF-501-A, Rev. 1, Relocate Stored Oil & Lube Oil Volume Values to Licensee Control2023-03-29029 March 2023 Application to Revise Technical Specifications to Adopt TSTF-501-A, Rev. 1, Relocate Stored Oil & Lube Oil Volume Values to Licensee Control ULNRC-06803, Submittal of Response to Request for Additional Information Regarding Results of Steam Generator Tube In-Service Inspection2023-03-29029 March 2023 Submittal of Response to Request for Additional Information Regarding Results of Steam Generator Tube In-Service Inspection ULNRC-06805, Transmittal of Special Report 2023-02 Non-Functionality of Containment Hydrogen Analyzer Channel for Greater than 30 Days2023-03-21021 March 2023 Transmittal of Special Report 2023-02 Non-Functionality of Containment Hydrogen Analyzer Channel for Greater than 30 Days ULNRC-06802, Special Report 2023-01 (PAM Report); Non-Functionality of a Post-Accident Monitoring Instrument2023-03-0909 March 2023 Special Report 2023-01 (PAM Report); Non-Functionality of a Post-Accident Monitoring Instrument ULNRC-06795, Submittal of Fitness for Duty Reports for 2022, Including Single Positive Test Forms2023-01-24024 January 2023 Submittal of Fitness for Duty Reports for 2022, Including Single Positive Test Forms ULNRC-06794, Submittal of Fitness for Duty Program Data for 20222023-01-24024 January 2023 Submittal of Fitness for Duty Program Data for 2022 ULNRC-06787, Response to Request for Additional Information Regarding License Amendment Request for Adoption of Alternate Source Term and Revision of Technical Specifications (LDCN 21-0015)2022-12-0808 December 2022 Response to Request for Additional Information Regarding License Amendment Request for Adoption of Alternate Source Term and Revision of Technical Specifications (LDCN 21-0015) ULNRC-06781, License Amendment Request to Clarify Support System Requirements for the Residual Heat Removal System and Control Room Air Conditioning System Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 (LDCN 22-0029)2022-12-0101 December 2022 License Amendment Request to Clarify Support System Requirements for the Residual Heat Removal System and Control Room Air Conditioning System Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 (LDCN 22-0029) ULNRC-06780, Additional Supplement to License Amendment Request to Adopt TSTF-439 and TSTF-505, LDCN 20-0072022-11-30030 November 2022 Additional Supplement to License Amendment Request to Adopt TSTF-439 and TSTF-505, LDCN 20-007 ULNRC-06772, 10 CFR 50.59 and 10 CFR 72.48 Summary Report2022-11-23023 November 2022 10 CFR 50.59 and 10 CFR 72.48 Summary Report ULNRC-06777, Operating Quality Assurance Manual (Oqam) Revision 362022-11-16016 November 2022 Operating Quality Assurance Manual (Oqam) Revision 36 ULNRC-06779, ULNRC-06779: Contesting of Green NCV 05000483/2022010-03, Failure to Perform Required Inservice Testing of Residual Heat Removal Heat Exchanger Pneumatically (Air) Operated Outlet and Bypass Valves2022-11-14014 November 2022 ULNRC-06779: Contesting of Green NCV 05000483/2022010-03, Failure to Perform Required Inservice Testing of Residual Heat Removal Heat Exchanger Pneumatically (Air) Operated Outlet and Bypass Valves ULNRC-06765, License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Testing Frequencies (LDCN 2020-0004)2022-11-0303 November 2022 License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Testing Frequencies (LDCN 2020-0004) ULNRC-06773, Results of Steam Generator Tube In-Service Inspection2022-11-0101 November 2022 Results of Steam Generator Tube In-Service Inspection ULNRC-06775, Submittal of Non-Functionality of Loose-Part Detection System Channel for Greater than 30 Days2022-10-27027 October 2022 Submittal of Non-Functionality of Loose-Part Detection System Channel for Greater than 30 Days ULNRC-06771, Correction to Application to Revise Technical Specifications to Adopt TSTF 577, Revised Frequencies for Steam Generator Tube Inspections (LDCN 21-0013)2022-10-25025 October 2022 Correction to Application to Revise Technical Specifications to Adopt TSTF 577, Revised Frequencies for Steam Generator Tube Inspections (LDCN 21-0013) ULNRC-06770, Cycle 25 Commitment Change Summary Report2022-10-19019 October 2022 Cycle 25 Commitment Change Summary Report ULNRC-06766, Correction of Text Contained in Enclosures Provided with Supplements to Request for License Amendment and Regulatory Exemptions for a Risk-Informed Approach to Address GSI-191 and Respond to GL 2004-02 (LDCN 19-0014)2022-09-0808 September 2022 Correction of Text Contained in Enclosures Provided with Supplements to Request for License Amendment and Regulatory Exemptions for a Risk-Informed Approach to Address GSI-191 and Respond to GL 2004-02 (LDCN 19-0014) ULNRC-06767, Presentation Information for Pre-Application Meeting Regarding New License Amendment Request for Use of Framatome Fuel Assemblies2022-09-0606 September 2022 Presentation Information for Pre-Application Meeting Regarding New License Amendment Request for Use of Framatome Fuel Assemblies ULNRC-06764, Revised Response to Request for Additional Information Regarding License Amendment Request for Adoption Off Alternate Source Term and Revision of Technical Specifications (LDCN 21-0015)2022-09-0101 September 2022 Revised Response to Request for Additional Information Regarding License Amendment Request for Adoption Off Alternate Source Term and Revision of Technical Specifications (LDCN 21-0015) ULNRC-06763, Supplement to Application to Revise Technical Specifications to Adopt TSTF 577, Revised Frequencies for Steam Generator Tube Inspection (LDCN 21-0013)2022-09-0101 September 2022 Supplement to Application to Revise Technical Specifications to Adopt TSTF 577, Revised Frequencies for Steam Generator Tube Inspection (LDCN 21-0013) ULNRC-06762, Submittal of Owner'S Activity Reports (OAR-1 Forms) for Cycle/Refuel 252022-08-25025 August 2022 Submittal of Owner'S Activity Reports (OAR-1 Forms) for Cycle/Refuel 25 ULNRC-06758, Union Electric Co. - Renewed Facility Operating License NPF-30, Withdrawal of License Amendment Request and Exemption Request Regarding Transition to Framatome Fuel (LDCN 22-0002)2022-08-0404 August 2022 Union Electric Co. - Renewed Facility Operating License NPF-30, Withdrawal of License Amendment Request and Exemption Request Regarding Transition to Framatome Fuel (LDCN 22-0002) ULNRC-06755, Response to Requests for Additional Information for Proposed Revision to Radiological Emergency Response Plan Regarding Response and Notification Goals2022-07-13013 July 2022 Response to Requests for Additional Information for Proposed Revision to Radiological Emergency Response Plan Regarding Response and Notification Goals ULNRC-06754, Response to Request for Additional Information Regarding Licensee Amendment Request for Adoption of Alternate Source Term and Revision of Technical Specifications2022-07-0505 July 2022 Response to Request for Additional Information Regarding Licensee Amendment Request for Adoption of Alternate Source Term and Revision of Technical Specifications ULNRC-06739, Post-Audit Supplement to License Amendment Request to Adopt TSTF-439 and TSTF-505 (LDCN 20-0007)2022-06-30030 June 2022 Post-Audit Supplement to License Amendment Request to Adopt TSTF-439 and TSTF-505 (LDCN 20-0007) ULNRC-06752, Evacuation Time Estimates Report2022-06-27027 June 2022 Evacuation Time Estimates Report ULNRC-06753, Presentation Information for Pre-Submittal Meeting Regarding Updated Spent Fuel Criticality Safety Analysis2022-06-23023 June 2022 Presentation Information for Pre-Submittal Meeting Regarding Updated Spent Fuel Criticality Safety Analysis ULNRC-06750, Submittal of Cycle 26 Core Operating Limits Report (COLR)2022-06-13013 June 2022 Submittal of Cycle 26 Core Operating Limits Report (COLR) ULNRC-06735, Response to Request for Additional Information Regarding Request for License Amendment and Regulatory Exemptions for Risk-Informed Approach to Address GSI-191 and Respond to Generic Letter 2004-02 (LDCN 19-0014).2022-05-27027 May 2022 Response to Request for Additional Information Regarding Request for License Amendment and Regulatory Exemptions for Risk-Informed Approach to Address GSI-191 and Respond to Generic Letter 2004-02 (LDCN 19-0014). 2024-01-29
[Table view] |
Text
AmerenUE PO Box 620 Callaway Plant Fulton, MO 65251 Apri126,2010 ULNRC-05697 u.s. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop Pl-137 Washington, DC 20555-0001 10 CFR 50.90 Ladies and Gentlemen:
~rt.. DOCKET NUMBER 50-483
~Ameren CALLAWAY PLANT UE UNION ELECTRIC CO.
APPLICATION FOR AMENDMENT TO FACILITY OPERATING LICENSE NPF-30 REVISION TO TECHNICAL SPECIFICATION 3.3.2 FUNCTION 6.g ENGINEERED SAFETY FEATURE ACTUATION SYSTEM (ESFAS) INSTRUMENTATION AUXILIARY FEEDWATER ACTUATION ON TRIP OF ALL MAIN FEEDWATER PUMPS TAC NO. ME3595 (LDCN 10-0011)
Reference:
ULNRC-05687 dated March 29,2010 In the above reference, AmerenUE submitted an application for amendment to Facility Operating License Number NPF-30 for the Callaway Plant.
That amendment application proposed changes to Technical Specification (TS) 3.3.2, "Engineered Safety Feature Action System (ESFAS) Instrumentation,"
that would revise Condition J to allow one or more inoperable channels for Function 6.g ofTS Table 3.3.2-1.
During the NRC staff s review a request for additional information (RAI) was identified. Attachment 1 provides the requested information. The information provided in Attachment 1 does not affect the licensing evaluations submitted in the referenced application or alter their conclusions.
AmerenUE continues to request approval ofthis proposed license amendment prior to May 14, 2010. AmerenUE further requests that the license amendment be made effective upon NRC issuance to be implemented within 30 days. As was the case with the referenced application, no commitments are contained in this correspondence.
a subsidiary of Ameren Corporation
ULNRC-05697 April 26, 2010 Page 2 If you have any questions on this amendment application or the attached information, please contact me at (573) 676-8719 or Mr. Thomas Elwood at (314) 225-1905.
I declare under penalty ofpeljury that the foregoing is true and correct.
Very truly yours, Executed on: J../ / lis, / 10 I D
~t-oJA.
Scott A. Maglio 9
Regulatory Affairs Manager : RAI Responses
ULNRC-05697 Apri126,2010 Page 3 cc: U.S. Nuclear Regulatory Commission (Original and 1 copy)
Attn: Document Control Desk Washington, DC 20555-0001 Mr. Elmo E. Collins, Jr.
Regional Administrator U.S. Nuclear Regulatory Commission RegionN 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Mohan C. Thadani (2 copies)
Senior Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop 0-8G14 Washington, DC 20555-2738
ULNRC-05697 April 26, 2010 Page 4 Index and send hardcopy to QA File A160.0761 Hardcopy:
Certrec Corporation 4200 South Hulen, Suite 422 Fort Worth, TX 76109 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)
Electronic distribution for the following can be made via Tech Spec ULNRC Distribution:
A. C. Heflin F. M. Diya L. S. Sandbothe C. O. Reasoner III S. A. Maglio S. L. Gallagher T. L. Woodward (NSRB)
T. B. Elwood G. G. Yates Ms. Diane M. Hooper (WCNOC)
Mr. Dennis Buschbaum (Luminant Power)
Mr. Ron Barnes (APS)
Mr. Tom Baldwin (PG&E)
Mr. Wayne Harrison (STPNOC)
Mr. John O'Neill (Pillsbury, Winthrop, Shaw, Pittman LLP)
Missouri Public Service Commission Mr. Dru Buntin (DNR)
Page 1 of3 RESPONSES TO NRC REQUEST FOR ADDITIONAL INFORMATION (RAI)
QUESTIONS REGARDING LICENSE AMENDMENT REQUEST LDCN 10-0011 By letter dated March 29,2010 (i.e., letter ULNRC-05687), AmerenUE (Callaway Plant licensee) submitted a request to amend Technical Specification 3.3.2 on an exigent basis.
The NRC staffhas reviewed the licensee's request and has identified a need for additional information. To complete its review of the proposed TS changes, the staff requests the licensee's response to the following two questions.
- 1. Has the licensee considered a redesign of the turbine-driven MFW pump oil pressure channels to avoid an incorrect status indication for the turbine-driven MFW pump when it is in reset?
Response
As discussed in the Operating Experience Review section of Attachment 1 to ULNRC-05687, under item 4.0 "Technical Analysis," the oil pressure channels serve their design function of indicating whether the main feedwater pump (MFP) turbines are tripped; however, those channels do not provide definitive indications that the MFPs are, in fact, providing feedwater flow to the steam generators. Low MFP turbine hydraulic oil pressure is a "direct" indication that the MFP turbine is tripped but an "indirect" indication ofthe MFP capability to supply feedwater to the steam generators. The MFP turbine hydraulic oil pressure provides a false indication of an MFP's capability to supply feedwater to the steam generators when the MFP turbine is "Reset" in MODES 1 and 2 but the pump is not actively supplying flow to the steam generators. This situation is routinely created during normal plant startup when one MFP is in operation but the other MFP turbine has been "Reset" for various maintenance and operational activities. Since the current version ofTS 3.3.2 Condition J does not recognize having more than one MFP trip channel inoperable, the plant is in a TS LCO 3.0.3 condition each time a MFP is placed in a "Reset" condition in the LCO Applicability when two channels are rendered inoperable but the MFP is not providing flow to the SGs.
Various redesign options and remedies for this situation might include:
- A design change could be pursued to install manual trip switches that would force a trip on the Function 6.g circuitry when a MFP turbine is "Reset" but the MFP is not yet providing feedwater flow to the steam generators. However, this would still require a change to Condition J ofTS 3.3.2 since two channels on the same MFP would be rendered inoperable by the forced trip. Artificially imposing a trip on the Function 6.g channels would make them incapable of responding as designed to their full range of inputs. The oil pressure switches can experience a pressure range of 0-200 psig. The expected performance of the switches is for the channel to trip at a decreasing pressure below 81.5 psig and for the channel to Page 2 of3 reset if the pressure rises 20 psi above the nominal setpoint. When a trip is forced on the channel, it can not meet this expected performance for the full range of inputs. The TS Definitions for Channel Calibration, Channel Operational Test, and TADOT require that an operable channel provide the desired outputs for known values of channel inputs. This design change would facilitate compliance with revised Action 1.1, but would not eliminate the need for the TS change to the TS 3.3.2 Condition I wording.
- A design change could be pursued to reduce the number of channels from two per MFP to one per MFP; however, this would require a TS change to the Required Channels column for Function 6.g ofTS Table 3.3.2-1. The advantage of this change would be that the existing TS 3.3.2 Condition I would cover the situation where one MFP is "Reset" and not providing feedwater flow to the steam generators since this would involve only one inoperable channel as opposed to the LCO 3.0.3 entry as discussed above. Disadvantages include loss of redundancy, increased likelihood of inadvertent AFW actuations, and maintaining separation criteria (if channell were associated with MFP 'A' and channel 4 were associated with MFP 'B', separation issues would have to be overcome for both channels providing inputs to the Channel I BOP ESF AS cabinet SA036A or to the Channel IV BOP ESF AS cabinet SA036B).
- A design change could be pursued to provide a different input to BOP ESF AS for AFW actuation on a loss of main feedwater flow; however, this would require a TS change to the title of Function 6.g in TS Table 3.3.2-1. For instance, the main feedwater flow transmitters could provide this input. However, these transmitters and the associated circuitry are non-Class IE and would have to be upgraded.
No design change could be implemented prior to the May 14, 2010 need date for this amendment. Design changes for Refuel 17 (which began on April 17, 2010) were issued to work planners over a year ago on April 5, 2009. A design change to Function 6.g, which is associated with the BOP ESF AS protection system, would only be prudent if due diligence and the proper attention to detail were given to developing the modification package and considering all ofthe consequences of that design change. This can not be accomplished prior to the established need date. In addition, none of the precedents and references cited in ULNRC-05687 included design changes at those plants.
AmerenUE does intend to pursue a different option for dealing with Function 6.g in the long term. As part of the risk-informed industry initiative 8a, we are evaluating whether this function is a candidate for relocation from TS 3.3.2 since it does not satisfy the criteria of 10 CFR 50.36(c)(2)(ii) for TS inclusion. It does not mitigate any accident (Criterion 3) nor is it risk-significant (Criterion 4). Likewise, Criteria 1 and 2 (reactor coolant pressure boundary degradation and initial condition of an accident analysis) do not apply to Function 6.g.
Page 3 of3
- 2. If a redesign were to be implemented, would the requested TS change still be required?
Response
See the response to question 1. The TS change is still required by May 14, 2010.