Identifies Changes That Should Be Made to 940418 Proposed Amend to License NPF-62 to Allow Adoption of Later Rev to ASTM Test Method Utilized for Periodic Testing of Charcoal Used in ESF Filter Sys,In Response to NRC Concerns
ML20069N305
Person / Time
Site: Clinton Constellation icon.png
Issue date: 06/16/1994
From: Jackie Cook
ILLINOIS POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20069N306 List:
References
JGC-119-94, U-602302, NUDOCS 9406220334
Download: ML20069N305 (3)


Text

.___ _- - _-_-___-___ - -

Ilhnois Power Cornpany e

Chnton Power Station '

P O Box 678 Chnton. IL 61727 Tel 217 935 5623 Fax 217 935-4632 V ce P es de POWER u-cono2 L47 94(06 -16 )LP 8E.100a JGC-119-94 June 16, 1994 Docket No. 50-461 10CFR50.90 Document Control Desk Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Clinton Power Station Revision to Previously Submitted Proposed Amendment of Facility Operating License No. NPF-62_(.LS-91-023)

Dear Sir:

By letter dated April 18,1994 (reference U-602243), Illinois Power (IP) requested amendment of Facility Operating License No. NPF-62, Appendix A-Technical Specifications (TS) for Clinton Power Station (CPS), to allow IP to adopt a later revision to the American Society for Testing and Materials (ASTM) test method utilized for periodic laboratory testing of the charcoal used in engineered safety feature filter systems.

IP's request was prompted by a recommendation from an NRC inspector. The approach taken at that time was to propose deletion of the year / revision of the ASTM Standard currently specified in the TS to allow the flexibility to adopt future revisions to this standard without the need to process a future TS change. This approach is consistent with the requirements currently contained in the TS for at least one other nuclear power plant.

The systems afTected by this proposed change are the standby gas treatment system (SGTS)(TS 3/4.6.6.3) and the main control room filter system (VC)(TS 3/4.7.2).

During the review ofIP's request, a number of concerns were expressed by the NRC staff. These included the fact that, although IP intended to adopt the revision of the ASTM D3803 standard that the NRC considers to be the best testing requirements currently available (the 1989 revision), the NRC staff does not intend to allow the use of later revisions which have not been reviewed and approved by the NRC stafT. In addition, based on the NRC stalTs experience with the results oflaboratory testing of nuclear grade charcoal, the NRC staff does not believe that testing at temperatures above 30 C is sufliciently conservative for predicting charcoal performance during accident conditions.

l The test conditions currently specified for the SGTS in the CPS TS include a temperature of80 C.

,, .n 9406220334 940616 PDR ADOCK 05000461 ,

P PDR l

U-602302 In response to the NRC staffs expressed concerns, IP has determined that two changes to IP's April 18,1994 amendment request should be made. These consist of(l) adding "-89" after "ASThi D3803" in the testing requirements specified for both the SGTS and VC charcoal, and (2) changing the test temperature specified for testing of the SGTS charcoal from 80 C to 30 C. (The test temperature for the VC system charcoalis currently specified as 30 C and would not be affected.) These changes are identified by double change bars on the attached pages from the CPS TS contained in Attachment 2 to this letter. The pages contained in Attachment 2 to this letter replace those previously submitted in Attachment 3 to U-602243. In addition, Attachment 3 to this letter contains a proposed correction to the Bases for TS 3.7.2. This correction is identical to that previously provided in Attachment 4 to U-602243 and is being resubmitted for completeness. The proposed changes to IP's Improved Technical Specifications (ITS) conversion submittal contained in Attachment 5 to U-602243 also require revision.

Ilowever, corrections to the ITS conversion submittal will be provided as part of the

" Proof and Review" comment resolution submittal to the NRC currently scheduled for July 1994. An affidavit supporting the facts set forth in this letter and its attachments is provided in Attachment 1.

IP has reviewed the changes requested by this letter and concluded that the basis for no significant hazards consideration and basis for meeting the 10CFR51.22(c)(9) criteria for a categorical exclusion from an Environmental Impact Statement provided in IP's April 18,1994 letter remain valid for this request.

Sincerely yours, e[ ft/

/ . G. Cook

( Vice President DAS/csm Attachments cc: NRC Clinton Licensing Project hianager NRC Resident Oflice, V-690 Regional Administrator, Region 111, USNRC lilinois Department of Nuclear Safety

Attachment 1 to U-602302 STATE OF ILLINOIS COUNTY OF DEWITT John G. Cook, being first duly sworn, deposes and says: That he is Vice President of Illinois Power Company; that the application for amendment of Facility Operating License NPF-62 has been prepared under his supervision and direction; that he knows the contents thereof, and that to the best of his knowledge and belief said application and the facts contained therein are true and correct.