TXX-7088, Interim Deficiency Rept CP-87-70 Re Potentially Reportable Item Involving Possible Violation of Prebend Pipe Wall Thickness.Initially Reported on 870824.Next Rept Will Be on 880311
| ML20237C966 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 12/18/1987 |
| From: | Counsil W, John Marshall TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| CP-87-70, TXX-7088, NUDOCS 8712220287 | |
| Download: ML20237C966 (1) | |
Text
_ _ - _ - _ _ _ _ _ _ _ _ _ _ _ _ _
!d
- Log '# TXX-7088 M
File # 10110 1
= = '
903.9
)
i 3
Ref. # 10CFP50.55(e).
=
=
1UELECTRIC
\\
December 18, 1987 William G. Counsil l
Eawutise Vice Picnident L.
U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
20555 l
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES) l l
DOCKET N05. 50-445 AND 50-446-
. PRE-BEND PIPE WALL THICKNESS SDAR: CP-87-70 (INTERIM REPORT).
.s Gentlemen:
On August 24, 1987, we verbally notifled your Mr. H. S. Phillips of a potentially reportable item involving possible violation of pre-bend pipe wall thickness due to inadequate QC inspection procedures.
This is an-interim report of a potentially reportable item under the provisions of 10CFR50.55(e).
Our last report was logged TXX-6759, dated September 22, 1987.
1 Our next report on this issue will be submitted no later than March 11, 1988.
j Very truly yours,
{t) k. 0n u s$ $
W. G. Counsil d
/
'2 By:
J. S. Marshall Supervisor, Generic Licensing HAM /grr c - Mr. R. D. Martin, Region IV Resident inspectors, CPSES (3)
I h22ggy ha p
S p1 '
400 lYonh Olive Street LB 81 lhollas, Tenas 75201 y
_ - _ _ - - - - - -