TXX-7074, Interim Deficiency Rept CP-87-12 Re Containment Pressure/Temp Analysis Computer Error.Initially Reported on 870612.Next Rept Will Be Submitted by 880227

From kanterella
(Redirected from TXX-7074)
Jump to navigation Jump to search
Interim Deficiency Rept CP-87-12 Re Containment Pressure/Temp Analysis Computer Error.Initially Reported on 870612.Next Rept Will Be Submitted by 880227
ML20237A604
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 12/10/1987
From: Counsil W, Woodlan D
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-87-12, TXX-7074, NUDOCS 8712150124
Download: ML20237A604 (1)


Text

.. _ _ _ _ _ _ - _

7.

M llllllll' =

Log # TXX-7074

',__,, 5 File # 10110

=

906.2 N/ ELECTRIC Ref. # 10CFR50.55(e) wmi in c. counsin December 10, 1987 lisecutise Vice Ptrsident U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.

20555

SUBJECT:

I COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET N05, 50-445 AND 50-446 CONTAINMENT P/T ANALYSIS COMPUTER ERROR SDAR: CP-87-12 (INTERIM REPORT)

Gentlemen:

On June 12, 1987, we notified you by our letter logged TXX-6512, of a deficiency involving a containment pressure / temperature analysis computer This is an interim report of a deficiency which is reportable under error.

the provisions of 10CFR50.55(e). Our most recent report was logged TXX-6617, dated August 5, 1987.

We will submit our next report by February 27, 1988.

Very truly yours, h, b. htc4 W. G. Counsil By:

D. R. Woodlan Supervisor, Docket Licensing JCfl/grr c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) 8712150124 871210 7

I PDR ADOCK 05000445

[

S DCD MK) North Olive Street LBEl Dallas. Teus 7201 0

- - - _ _ - -