TXX-6878, Interim Deficiency Rept CP-87-44 Re Spec CPES-1-1018 Which Allows Use of Either ASTM A-307,Grade a or B or SAE J-429, Grade 1 or 2 Bolting in Tubing Supports.Initially Reported on 870717.Evaluation Continuing.Next Rept by 880107

From kanterella
(Redirected from TXX-6878)
Jump to navigation Jump to search
Interim Deficiency Rept CP-87-44 Re Spec CPES-1-1018 Which Allows Use of Either ASTM A-307,Grade a or B or SAE J-429, Grade 1 or 2 Bolting in Tubing Supports.Initially Reported on 870717.Evaluation Continuing.Next Rept by 880107
ML20236C481
Person / Time
Site: Comanche Peak  
Issue date: 10/23/1987
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-87-44, TXX-6878, NUDOCS 8710270215
Download: ML20236C481 (1)


Text

__

l i

F Log # TXX-6878 l

Fi1e # 10110 l-

=

=

903.9 M/ ELECTRIC Ref.# 10CFR50.55(e)

I l

, William G. Counsil l

emota, vic, riesisen, October 23, 1987 i

U. S. Nuclear Regulatory Commission 1

l Attn: Document Control-Desk g

Washington,- D. C.

20555 s

8C$

SUBJECT:

COMANCHE PEAK. STEAM ELECTRIC STATION (CPSES)

_ 1 :7 DOCKET NOS. 50-445 AND.50-446 o

UNISTRUT-TUBING' SUPPORT BOLTING

/

SDAR: CP-87-44 (INTERIM REPORT)

->g Gentlemen:

w On July 17, 1987, we verbally notified your Mr. Ian Barnes of a deficiency involving Specification CPES-1-1018 (Installation of Piping / Tubing and Instrumentation) which allows the use of either ASTM A-307, Grade A or B or SAE J-429, Grade 1 or 2 bolting in tubing supports. This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e). Our latest interim report was logged TXX-6644, dated August 17, 1987, i

-The majority of safety-related tubing supports are fabricated utilizing 1

-(ypical Unistrut members and joint configurations.Unistrut Catalog 10R 1

.t dated 1986) requires the use of SAE J-429 Grade 2 bolts.

The torquing requirements specified by Unistrut for SAE J-429, Grade 2 bolts results in a tensile stress which could cause " permanent set" if ASTM A-307, Grade A or B bolts are used'instead of SAE J-429, Grade 2.

These conditions could result-in unpredictable bolting clamping forces and unknown load limits.

Our evaluation of this condition is continuing. Our next report on this issue will be submitted no later than January 7, 1988, i

Very truly yours, 8710270215 871023

C W. G. Counsil DAR/gj c - Mr. R. D. Martin, Region IV Resident In',pectors, CPSES (3) dl P ib
  1. 0 North Olwe Street LB 81 Dallas. Texas 75201