TXX-6851, Interim Deficiency Rept CP-87-103 Re Cracked Gears in Valve Operators.Initially Reported on 870911.Evaluation Continuing.Next Rept Will Be Submitted by 871211
| ML20235V745 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 10/08/1987 |
| From: | Counsil W, John Marshall TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| CP-87-103, TXX-68513, NUDOCS 8710150301 | |
| Download: ML20235V745 (1) | |
Text
_ _.
I M
i 2M Log # TXX-6851 i
h j
File # 10110 I
=
=
903.9 Ref # 10CFR50.55(e) 7t1 ELECTRIC October 8, 1987 William G. Counsil l
Executive Vice Pernideret V. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET N05. 50-445 AND 50 446 CRACKED GEARS IN VALVE OPERATORS SDAR: CP-87-103 (INTERIM REPORT)
Gentlemen:
On September 11, 1987, we verbally notified your Mr. H. S. Phillips of a deficiency involving cracked gears in valve operators.
Specifically, cast bronze sector gears, used in Limitorque HBC-3 valve drives, were discovered to have visible defects and cracks in the web area where they bolt to the drive sleeves.
This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e).
We are continuing our evaluation and anticipated submitting our next report by l
December 11, 1987.
l Very truly yours, 6d. G. Gu sII W. G. Counsil l
By 4^d a J. S. Marshall Supervisor, Generic, Licensing CBC/grr c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3)
/,h 8710150301 87]oog gDR ADOCK 05000445 PDR T/