TXX-6839, Interim Deficiency Rept CP-87-16 Re Conduit & Cable Which Feed safety-related Valve Limit Switches Not Installed in Accordance W/Wiring Drawings.Initially Reported on 870601. Evaluation Continuing.Next Rept Will Be Submitted by 871211
| ML20235V114 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 10/05/1987 |
| From: | Counsil W, John Marshall TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| CP-87-16, TXX-6839, NUDOCS 8710140595 | |
| Download: ML20235V114 (1) | |
Text
- - _ _ - - - - -
- i 2
n MM Log # TXX-6839 k
L d
File # 10110-907
~---
7.
TilELECTRIC
"*' ~# 10CIR00'00('I William G. Counxil em,-c wu eu.,uw October 5, 1987
' U. S. Nuclear Regulatory Commission Attn: Document Control Desk
. Washington, D. C.
20555-
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET N05, 50-445 AND 50-446 LIMIT SWITCH WIRING SDAR: CP-87-16 (INTERIM REPORT)
Gentlemen:
On June 1, 1987, we verbally notified your Mr. H. S. Phillips of a deficiency involving conduit and cable which feed safety related valve limit switches and which were not installed in accordance with the wiring drawings.
This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e). Our most recent interim report was logged TXX-6632, dated August 7, 1986.
We are continuing our evaluation and anticipate submitting our next report by December 11, 1987.
Very truly yours,
&. (, 0a M W. G. Counsil Byv
'J. S. Marshall Supervisor, Generic Licensing
-JCH/gj c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) 8710140595 871005
{DR ADOCK 0500044g PDR-p1 ll6 w
ce nores ative sarcca to si varias. rc<a,15:o1