TXX-6672, Interim Deficiency Rept CP-86-72 Re Scope of Plant Mods from Project Pipe Support Validation Program.Initially Reported on 860609.List of Support Mods Issued to Date Encl. Evaluation Continuing.Next Rept Will Be Submitted by 871120

From kanterella
(Redirected from TXX-6672)
Jump to navigation Jump to search
Interim Deficiency Rept CP-86-72 Re Scope of Plant Mods from Project Pipe Support Validation Program.Initially Reported on 860609.List of Support Mods Issued to Date Encl. Evaluation Continuing.Next Rept Will Be Submitted by 871120
ML20237G866
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/20/1987
From: Counsil W, Keeley G
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-86-72, TXX-6672, NUDOCS 8708240275
Download: ML20237G866 (2)


Text

l

  • l

, Log # TXX-6672 Fi1e # 10110

--  : 903.9 E E Ref. # 10CFR50.55(e) 1UELECTRIC Wmiarn G. Counsil becunve Vwe heside,w U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHEPEAKSTEAMELECTRICSTATION(CPSES) 00CKETS N05. 50-445 AND 50-446 SMALL BORE PIPING AND SUPPORTS SDAR: CP-86-72 (INTERIM REPORT)

Gentlemen:

On June 9, 1986, we verbally notified you of a reportable item involving the scope of plant modifications resulting from the project's pipe support validation program (see TXX-4844). This is a follow-up interim report on a reportable item under provisions of 10CFR50.55(e). Our latest interim report logged TXX-6507 was submitted on June 12, 1987.

The continuing engineering evaluation has not identified any additional instances which are considered reportable pursuant to 10CFR50.55(e). The attached list shows the support modifications issued to date. The evaluation is continuing and we anticipate submitting our next report by November 20, 1987.

Very truly yours, W. G. C unsil

$h0]Qy h By: k, /[

s G. S. Keeley m / __

Manager,NuclearLicpsing BSO/amb Attachment c - Mr. R. D. Martin, Region IV q Resident Inspectors, CPSES (3) 9 s\

400 North Olive Street LB 81 Dallas, Texas 73201

. . . . . . _ - - _ - 1

3 Attachment to TXX-6672 August 20, 1987 Page 1 of 1 1

ATTACHMENT 4 SMALL BORE PIPE SUPPORT MODIFICATIONS Number of Unit Category Modifications

  • 1 Prudent 87 l Recent Industry Practice 409 Adjustment 270 l Cumulative Effects 655 i 2 Prudent 26 I Recent Industry Practice 89 l Adjustment 70 Cumulative Effects 152
  • Changes in these figures from the last report represent not only identification of further modifications but a recategorization of certain supports.

s,