TXX-6493, Interim Deficiency Rept CP-86-62 Re Misinterpretation of Polar Crane Load Cases Deemed Reportable Under 10CFR50.55(e).Initially Reported on 861003.Next Rept Will Be Submitted by 870925
| ML20214W239 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 06/08/1987 |
| From: | Counsil W TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| CP-86-62, TXX-6493, NUDOCS 8706150172 | |
| Download: ML20214W239 (1) | |
Text
Log # TXX-6493 File # 10110 903.8 FE Ref # 10CFR50.55(e) 2 C
=
=
1UELECTRIC June 8, 1987 William G. Counsil Executive Vke he &nt U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKETS NOS. 50-445 AND 50-446 POLAR CRANE SUPPORT STRUCTURE SDAR: CP-86-62 (INTERIM REPORT)
Gentlemen:
On October 3,1986, we notified you by our letter logged TXX-6011 of a deficiency involving a misinterpretation of the polar crane load cases which we deemed reportable under the provisions of 10CFR50.55(e).
Our latest interim report logged was TXX-6346 dated March 23, 1987. This is an interim report submitted to status corrective action implemented to date.
In previous reports, we concluded that reduced loading exists for the polar crane support structure. An analysis of the acceptability of the crane rail structure for these reduced loads is continuing.
We will submit our next report no later than September 25, 1987.
Very truly yours,
/
W W. G. Counsil RWH/gj c - R. D. Martin - Region IV CPSES Resident Inspector - 3 copies 8706150172 870600 gI PDR ADOCK 05000445 S
PDR j
/
t 400 North Olive Street LB 81 Dallas, Tens 75201
.