TXX-6248, Interim Deficiency Rept CP-85-35 Re Cable Tray Hanger Design.Initially Reported on 861021.Support Testing & Verification Programs Continuing.Next Rept Expected by 870706

From kanterella
(Redirected from TXX-6248)
Jump to navigation Jump to search
Interim Deficiency Rept CP-85-35 Re Cable Tray Hanger Design.Initially Reported on 861021.Support Testing & Verification Programs Continuing.Next Rept Expected by 870706
ML20209B646
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 01/30/1987
From: Counsil W, Keeley G
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
CP-85-35, TXX-6248, NUDOCS 8702040091
Download: ML20209B646 (1)


Text

Lcg # TXX-6248 File # 10110 903.9 Re:10CFR50.55(e)

""" 7

~

--=

=

1EIELECTRIC January 30, 1987 m,,

Iserunw Yke l>eshkw U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 CABLE TRAY HANGER DESIGN SDAR: CP-85-35 (INTERIM REPORT)

Gentlemen:

On October 21, 1986, we notified you by our letter logged TXX-6048 of a deficiency involving the design and construction activities of the cable tray support program which we deemed reportable under the provisions of 10CFR50.55(e). This is an interim report submitted to status corrective action implemented to date.

The cable tray support testing and verification programs are continuing.

The testing program and evaluation of test results are currently scheduled for completion by June 12, 1987.

Our next report on this issue will be submitted no later than July 6,1987.

Very truly yours, hY oun i W. G.fC unsil By:

M

//

G. S. Keeley

~/

m Manager, Nuclear p ensing DAR:1w c - Mr. E. H. Johnson, Region IV Mr. D. L. Kelley, RI - Region IV Mr. H. S. Phillips, RI - Region IV 8702040091 870130 PDR ADOCK 05000445 S

PDR

[

O 4m North Olne Street l.. it. M l Dallas. Ieus 75201

\\