TXX-4764, Part 21 & Interim Deficiency Rept CP-86-15 Re Tdi Field Flash & K1 Relays Provided W/Rating That Does Not Meet Spec Requirements.Initially Reported on 860314.Evaluation Continuing.Next Rept Expected by 860516
| ML20203P512 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 04/14/1986 |
| From: | Counsil W, Keeley G TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Johnson E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| REF-PT21-86, REF-PT21-86-159-000 CP-86-15, PT21-86-159, PT21-86-159-000, TXX-4764, NUDOCS 8605070381 | |
| Download: ML20203P512 (1) | |
Text
Log i TXX-4764
=
File # 10110 909.5 TEXAS UTILITIES GENERATING COMPAhT MKYW AY TOWER
- 400 NOR1,, OtJVE WTREET. I.B. E l e ll AIJAm. TEX AS 7530 0 April 14, 1986 E M C k ?N U.h 7%)
$.N l
\\ $ \\ T \\? f J
Mr. Eric H. Johnson, Director Division of Reactor Safety and Projects h
j U.S. Nuclear Regulatory Comission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76012
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION DOCKET NOS. 50-445 AND 50-446 DIESEL GENERATOR CONTROLS SDAR: CP-86-15
Dear Mr. Johnson:
On March 14, 1986, we verbally notified your Mr. T. F. Westerman of a deficiency involving the field _ flash and K1 relays which are required to operate during the starting process of the diesel generators.
These relays were provided with a rating that does not meet specification requirements.
This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e).
The issue was reported to the NRC by a Part 21 notice issued by the supplier (Delaval). We are continuing our evaluation and anticipate submitting our next report by May 16, 1986.
Very truly yours, G'n W. G. Cou sil 8605070381 860414
/
PDR ADOCK 05000445 g
PDR-4 h -
G. S. Keeley ^ -
Manager, Nuclear % censing JCH/ arm c-NRC Region.IV (0 + 1 copy)
Director, Inspection & Enforcement (15 copies)
U. S. Nuclear Regulatory Commission Washington, D.C.
20555
\\
A DEVENION OF TEKAN t1Til2TIEN E12CE'NIC (Y)MPANY a