TXX-4728, Interim Deficiency Rept CP-86-08 Re Control of Stamps Used to Identify Super Hilti Kwik Bolts.Initially Reported on 860206.Field Insps Identified Pipe Supports Possibly Affected by Deficiency.Next Rept to Be Submitted by 860424

From kanterella
(Redirected from TXX-4728)
Jump to navigation Jump to search
Interim Deficiency Rept CP-86-08 Re Control of Stamps Used to Identify Super Hilti Kwik Bolts.Initially Reported on 860206.Field Insps Identified Pipe Supports Possibly Affected by Deficiency.Next Rept to Be Submitted by 860424
ML20141N654
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 03/07/1986
From: Council W, Counsil W, Keeley G
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
CP-86-08, CP-86-8, TXX-4728, NUDOCS 8603170453
Download: ML20141N654 (1)


Text

- .

Log # TXX-4728 File i 10110 TEXAS UTILITIES GENERATING COMPANY SKYW AY TOWER e 400 NORTIE OLIVE STREET. 8.R. S 8 e DALLAS, TEEAS 7890 8 -

March 7, 1986

  1. 3Y,'"Af0."*#, -

E -_

l

$ kl 0 Svf @

Mr. Eric H. Johnson, Director J> ~~~ m  !

Division of Reactor Safety and Projects e!

U.S. Nuclear Regulatory Commission J b(;['

01506 "If -

611 Ryan Plaza Drive, Suite 1000 y Arlington, TX 76012 o

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION DOCKET NOS. 50-445 AND 50-446 INSTALLATION OF SUPER HILTI KWIK BOLTS SDAR: CP-86-08

Dear Mr. Johnson:

On February 6, 1986, we verbally notified your Mr. T. Westerman of a deft-ciency involving the control of stamps used to identify super hilti kwik bolts. This is an interim report of a potentially reportable item under the provisions of 10 CFR 50.55(e). Currently field inspections have iden-tified pipe supports possibly affected by this issue. Based upon an engi-neering evaluation of these installations the significance of this concern can be assessed and any further veri'ication/ evaluation will be determined.

We are continuing our evaluation and will submit our next report by April 24, 1986.

Very truly yours, w.G.Gudl W. G. Counsil B' '

8603170453 860307 #' . 5. Keel G

PDR ADOCK 05000445 s PDR Manager, Nu L censing JCH/ arm c - NRC Region IV (0 + 1 copy)

Director, Inspection & Enforcement (15 copies)

U. S. Nuclear Regulatory Commission 50 Washington, D.C. 20555 A

.