Text

-

l TEXAS UTILITIES GENERATING COMPANY

. W KT WAY Te tWER

  • 100 NOHTil E DLIVE hil.EET L.fl. MS
  • 13 ALLAH. TEXAM T3201 August 9,

1985 wim u.o.cousm TXX-4532 Mr. D.R. Hunter, Chief Reactor Project Branch 2 U.S. Nuclear Regulatory Commission Office o' Inspection & Enforcement 611 Ryan Plaza Drive, Suite 1000 Docket No.

50-445 l

Arlington, TX 76012 l

l COMANCHE PEAK STEAM ELECTRIC STATION l

UPPER LATERAL RESTRAINT EMBEDMENT DESIGN QA FILE: CP-85-26, SDAR-187 FILE N0.:

10110

Dear Mr. Hunter:

}

On July 19, 1985 we verbally notified your D. Powell of a deficiency regarding the deviation from FSAR criteria in the design of the Unit 1 Steam Generator upper restraint embedment.

We are continuing our evaluation and anticipate completion by November 22, 1985.

Very truly yours, 4/f8 W.G. Counsil WGC:tig cc: NRC Region IV - (0 + 1 copy) gg g

Director, Inspection & Enforcement (15 copies) i U.S. Nuclear Regulatory Commission

.- MI2 m (R1 Washington, DC 20555 Ig 85002%k $h"45 A ').o 6

%9 IE-3G

..,,,,,,,,,,., r

. v T,,.,,. - c,,, c v. m..-