TXX-4481, Final Deficiency Rept SDAR-169 Re Sump Isolation Valve Motors Unqualified Environmentally for Svc Conditions. Initially Reported on 850215.Condition Not Reportable Under 10CFR50.55(e)
| ML20126B039 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 05/28/1985 |
| From: | Clements B TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Hunter D NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| SDAR-169, TXX-4481, NUDOCS 8506130551 | |
| Download: ML20126B039 (1) | |
Text
--.
JUN - 41985 TEXAS UTILITIES GENERATING COMPANY MKYWAY TOWER. 400 NORTH OLIVE MTREET. L.B. At. DALLAM.TEXAM 75201 p
i m f',S, llc'i"",,"L*,,,,,,
May 28, 1985 TXX-4481 Mr. 0.Rt Hunter, Chief' Reactor Project Branch 2 U.S. Nuclear Regulatory Commission Office of Inspection & Enforcement 611 Ryan Plaza Drive, Suite 1000 Docket Nos.:
50-445 Arlington, TX 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION SUMP ISOLATION VALVE MOTORS QA FILE:
CP-85-08, SDAR-169 FILE N0.:
10110
Dear Mr. Hunter:
On February 15, 1986 we verbally notified your Mr. D. Hunnicutt of a deficiency regarding the sump isolation valve motors that were not' qualified environmentally per IEEE-323 (74) for service conditions. We submitted an interim report logged TXX-4434 dated March 5, 1985.
We have completed our investigation and concluded that the matter is not reportable under 10CFR50.55(e).
Records supporting this determination are available for your inspector's review at the CPSES site.
Very truly yours, YtmaY BRC:tig-cc: NRC Region IV (0 + 1 copy)
Director, Inspection & Enforcement (15 copies)
U.S. Nuclear Regulatory Commission Washington, DC 20555-8506130551 850 pj5 ADOCK 0 gDR pW paq g
..,,.. nn n, T-.,,
.e ci. c cn
,n r e o i
u