TXX-4460, Final Significant Deficiency Rept SDAR-176 Re Equipment Hatch Cover in Reactor Containment Bldg W/Attachments Bearing Against I Beams When Positioning Cover.Item Not Reportable Per 10CFR50.55(e)
| ML20116G781 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 04/17/1985 |
| From: | Wells J TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Hunter D NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| SDAR-176, TXX-4460, NUDOCS 8505010604 | |
| Download: ML20116G781 (1) | |
Text
-
TEXAS UTILITIES GENERATING COMPANY HKYWAY TOWER. 400 NOHTH OLIVE MTHEET, L.H. Ma
- DALLAM, TEXAM 73201 April 17, 1985 TXX-4460 Mr. D.R. Hunter, Chief Reactor Project Branch 2 U.S. Nuclear Regulatory Commission Office of Inspection & Enforcement 611 Ryan Plaza Drive, Suite 1000 Docket No.: 50-445 Arlington, TX 76012 COMANCHE PEAK STEAM ELECTRIC STATION UNIT 1 EQUIPMENT HATCH QA FILE: CP-85-15, SDAR-176 FILE NO.:
10110
Dear Mr. Hunter:
On March 28, 1985 we verbally notified your Mr. D. Hunnicutt of a deficiency regarding the equipment hatch cover in Unit 1 Reactor Containment Building that has attachments / guides which bear against I beams when positioning the hatch cover.
We have completed our investigation and concluded that the matter is not reportable under 10CFR50.55(e). Records suppcrting this determination are available for your inspector's review at the CPSES site.
Very truly yours, n
)
Ah J.R. Wells Director, Quality Assurance JRW:tig cc: NRC Region IV - (0 + 1 copy)
Director, Inspection & Enforcement (15 copies)
U.S. Nuclear Regulatory Commission g @ Q QM@ h Washington, DC 20555 APR I 9885 3
J -
8505010604 850417 PDR ADOCK 05000445 g
PDR Th0]
-QJT a DurussOx Or rexas n r:1.srien zu.ecrunc cu>>uraxv