TXX-4330, Interim Deficiency Rept SDAR-140 Re Main Steam Relief Valves Not Qualified for Actual Loading Conditions.Initially Reported on 840710.Item Not Reportable Per 10CFR50.55(e)

From kanterella
(Redirected from TXX-4330)
Jump to navigation Jump to search
Interim Deficiency Rept SDAR-140 Re Main Steam Relief Valves Not Qualified for Actual Loading Conditions.Initially Reported on 840710.Item Not Reportable Per 10CFR50.55(e)
ML20106D863
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 10/08/1984
From: Clements B
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Hunter D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
SDAR-140, TXX-4330, NUDOCS 8410260202
Download: ML20106D863 (1)


Text

TEXAS UTILITIES GENERATING COMPANY MKYWAY TOWER . 400 NORTH OLIVE MTNEET. L.B. SI . DALLAM. TEXAM 7S301 m "'fo!"'E'"'4L*= October 8, 1984 TXX-4330

]@ @ % $3,  !

OCT I 2W Mr. D.R. Hunter, Chief Reactor Project Branch 2 . -

g U.S. Nuclear Regulatory Commission Office of Inspection & Enforcement 611 Ryan P1 aza Drive, Suite 1000 Docket No.: 50-445 Arlington, TX 76012 COMANCHE PEAK STE/M ELECTRIC STATION QUALIFICATION OF MAIN STEAM RELIEF VALVES QA FILE: CP-84-16, SDAR-140

' FILE N0.: 10110

Dear Mr. Hunter:

On July 10, 1984 we verbally notified your Mr. D. Hunnicutt of a deficiency regarding several main steam relief valves that may not be qualified for actual loading conditions. We have submitted interim reports logged TXX-4250 and TXX-4291 dated August 8,1984 and August 30, 1984.

We have completed our investigation and concluded that the matter is not reportable under 10CFR50.55(e). Records supporting this determination are available for your inspector's review at the CPSES site. .

Very truly yours,

. n

/  %

BRC:tig cc: NRC Region IV - (0 + 1 copy)

Director, Inspection & Enforcement (15 copies)

U.S. Nuclear Regulatory Ccmmission Washington, DC 20555 8410260202 641008 PDR ADOCK 05000445 S PDR I -

A DRVlNION 00' TEXAN l'TILITIER ELECTRIC COMi'ANY l l

l n c -- .