TXX-4292, Interim Deficiency Rept SDAR-145 Re Piping Matl That Does Not Meet Ultrasonic Test Requirements for NB-2500 ASME Class 1 Applications.Initially Reported on 840815.Upon Completion of Investigation,Matter Determined Not Reportable
| ML20097A812 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 08/30/1984 |
| From: | Clements B TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Johnson E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| SDAR-145, SPDAR-145, TXX-4292, NUDOCS 8409130392 | |
| Download: ML20097A812 (1) | |
Text
TEXAS UTILITIES GENERATING COMPANY MKYWAY TOWER. 400 NORTH., LIVE MTREET, L.B. Al. DALLAN. TEXAM 73201
-. -.u.. y,. cu..m..u.r.
August 30,._1S84
.i
}g@7M Txx-4292 tb SEF - 41984 e
b I
Mr. E.H. Johnson, Chief Reactor Project Branch 1 U.S. Nuclear Regulatory Commission Office of Inspection & Enforcement 611 Ryan Plaza Drive, Suite 1000 Docket Nos.:
50-445 Arlington, Tx 76012 50-446 C01ANCHE PEAK STEAM ELECTRIC STATION UT REQUIREMENTS:
CLASS 1 PIPING QA FILE:
CP-84-21, SDAR-145 FILE N0.:
10110
Dear Mr. Johnson,
On August 15, 1984 we verbally contacted your Mr. D. Hunnicutt of a deficiency regarding piping material that does not meet the ultrasonic test requirements for NB-2500 A91E Class 1 applications.
We have completed our investigation and concluded that the matter is not reportable under 10CFR50.55(e). Records supporting this detennination are available for your inspector's review at the CPSES site.
Very truly yours, WsY BRC/tig cc: fRC Region IV - (0 + 1 copy)
Director, Inspection & Enforcement (15 copies)
U.S. Nuclear Regulatory Commission Washington, DC 20555 8409130392 840830 PDR ADOCK 05000445 S
(, b
$o A,,,,,,,...
...A.,
,L,...L.c c._,.A
.