TXX-4270, Final Deficiency Rept Re Defective Diesel Generator Valve Springs.Initially Reported on 840720.Condition Not Reportable Under 10CFR50.55(e)

From kanterella
(Redirected from TXX-4270)
Jump to navigation Jump to search
Final Deficiency Rept Re Defective Diesel Generator Valve Springs.Initially Reported on 840720.Condition Not Reportable Under 10CFR50.55(e)
ML20095H148
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/20/1984
From: Clements B
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
SDAR-145, TXX-4270, NUDOCS 8408280375
Download: ML20095H148 (1)


Text

  1. ~

TEXAS UTILITIES GENERATING COMPANY MF YWAY TOWER. 400 NORTH OLIVE NTHEET. L.B. M1

  • DALLAN, TEXAN 75201 t'

.. "'P1hcif."'41.

August 20, 1984 TXX-4270

})B@MDWM Mr. E.H. Johnson, Chief

\\

AUG 2 21984 Reactor Project Branch 1 J

U.S. Nuclear Regulatory Commission

~

Office of Inspection & Enforcement l

611 Ryan Plaza Drive, Suite 1000 Docket Nos.:

50-445 Arlington, TX 76012 50-446 CCHANCHE PEAK STEAM ELECTRIC STATION DIESEL GENERATOR MATERIAL DEFECT i

(VALVE SPRINGS)

QA FILE: CP-84-19, SDAR-145 l

FILE NO.:

10110

Dear Mr. Johnson,

On July 20, 1984, we verbally contacted your Mr. D. Hunnicutt of a deficiency regarding possible material defect in the Diesel Generator valve springs.

We have completed our investigation and concluded that the matter is not reportable under 10CFR50.55(e). Records supporting this determination are available for your inspector's review at the CPSES site.

l l

Very truly yours, kat BRC/tlg cc:

IRC Region IV - (0 + 1 copy)

Director, Inspection & Enforcement (15 copies) i U.S. Nuclear Regulatory Commission Washington, DC 20555

% 7 j

8 0 1

1 8408280375 840820 I

PDR ADOCK 05000445 S

PDR t