TXX-4248, Final Deficiency Rept SDAR-129 Re Error in Tolerances Used in Calibr of Adhesion Tester.Initially Reported on 840116. Investigation Complete.Matter Not Reportable Under 10CFR50.55(e)

From kanterella
(Redirected from TXX-4248)
Jump to navigation Jump to search
Final Deficiency Rept SDAR-129 Re Error in Tolerances Used in Calibr of Adhesion Tester.Initially Reported on 840116. Investigation Complete.Matter Not Reportable Under 10CFR50.55(e)
ML20094P044
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/06/1984
From: Clements B
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
SDAR-129, TXX-4248, NUDOCS 8408160510
Download: ML20094P044 (1)


Text

y

@@M OWM 4 TEXAS UTILITIES GENERATING COMPANY M -0E MKYWAY TOWEff . 400 NORTH OLIVE HTREET, L.8. fit . DALLAN,TEXAM TSSO mi$ifffd'f*,.. August 6, 1984 TXX-4248 Mr. E.H. Johnson, Chief Reactor Project Branch 1 U.S. Nuclear Regulatory Comission Office of Inspection & Enforcement 611 Ryan Plaza Drive, Suite 1000 Docket Nos.: 50-445 Arlington, TX 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION PROTECTIVE C0ATINGS ADHESION TESTER QA FILE: CP-84-05, SDAR-129 FILE N0.: 10110

Dear Mr. Johnson,

On January 16, 1984 we verbally contacted your Mr. R.G. Taylor of a deficiency regarding an error in the tolerances used in the calibration of the adhesion tester. We have submitted interim reports logged TXX-4111, TXX-4168, and TXX-4244 dated February 15, 1984, May 11, 1984, and July 31, 1984.

We have completed our investigation and concluded that the matter is not reportable under 10CFR50.55(e). Records supporting this detennination are available for your inspector's review at the CPSES site.

Very truly yours, km Billy R. Clements BRC:tig cc: tRC Region IV - (0 + 1 copy)

Director, Inspection & Enforcenent (15 copies)

U.S. Nuclear Regulatory Commission Washington, DC 20555 8408160510 840806 PDR ADOCM 05000445 S PDR &

A........-......,.........,..,._

.y