TXX-4110, Final Deficiency Rept Re Stainless Steel Tubing Observed Cracked.Investigation Complete.Matter Not Reportable Under 10CFR50.55(e)

From kanterella
(Redirected from TXX-4110)
Jump to navigation Jump to search
Final Deficiency Rept Re Stainless Steel Tubing Observed Cracked.Investigation Complete.Matter Not Reportable Under 10CFR50.55(e)
ML20080M945
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 02/13/1984
From: Gary R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
TXX-4110, NUDOCS 8402220033
Download: ML20080M945 (1)


Text

__ ____ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ._ ___

TEXAS UTILITIES GENERATING COMPANY m KT WAT TOWEH

  • endt MOH111 OE,IV E MTHEET. l..H. NI 'IBAI.E.AM.1 >:XA*.13208 R.J. GARY

.:.... . . ........' February 13, 1984 TXX-4110 Mr. E. H. Johnson, Chief Reactor Project Branch 1 U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement bil Ryan Plaza Drive, Suite 1000 Docket Nos.: 50-445 Arlington, TX 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION INSTRUMENT TUBING QA FILE: CP-84-03, SDAR-127 FILE: 10110

Dear Mr. Johnson:

On January 16, 1984, we verbally informed your Mr. R. G. Taylor of a deficiency regarding stainless steel tubing which has been observed cracked.

We have completed our investigation and concluded that the matter is not reportable under 10CFR50.55(e). Records suporting this determination are available for your Inspector's review at the CPSE5. site.

Very truly yours, hbM RJG:In cc: NRC Region IV - (0 + 1 copy)

Director, Inspection & Enforcement (15 copies)

U.S. Nuclear Regulatory Commission Washington, DC 20555 g22M[o S

3 E .R 7 A MFfMION OF TNMN PTf f.fffRN NE.ECTNic COMi%NT