TXX-3604, Final Deficiency Rept Re Pipe Whip Restraint Weld Indications.Initially Reported on 820930.Condition Determined Not Reportable Per 10CFR50.55(e)

From kanterella
(Redirected from TXX-3604)
Jump to navigation Jump to search
Final Deficiency Rept Re Pipe Whip Restraint Weld Indications.Initially Reported on 820930.Condition Determined Not Reportable Per 10CFR50.55(e)
ML20064D032
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 12/27/1982
From: Gary R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, TXX-3604, NUDOCS 8301040545
Download: ML20064D032 (1)


Text

-- . _ _ _ _ _ _

TEXAS UTILITIES GENERATING CO3fPANY mn mn muwen nm.mmm.uomno ,7 - ,

dis?sL.- IEC 29 W December 27, 1982 TXX-3604 Mr. G. L. Madsen, Chief Reactor Project Branch 1 U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement 611 Ryan Plaza Drive, Suite 1000 Docket Nos.: 50-445 Arlington, Texas 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION PIPE WHIP RESTRAINT WELD INDICATIONS SDAR-95; CP-82-12 FILE NO.: 10110

Dear Mr. Madsen:

On September 30, 1982, we verbally informed your Mr. R. G. Taylor of a deficiency regarding weld indications in certain pipe whip restraints.

We submitted an interim report logged TXX-3584 on October 25, 1982.

We have completed our investigation and concluded that the matter is not reportable under 10 CFR50.55(e). Records supporting this determination are available for your Inspector's review at the CPSES site.

Very truly yours, f.. . Gary R.

RJG:eaq cc: NRC REGION IV - (0 + 1 copy)

Director, Inspection & Enforcement (15 copies)

U. S. Nuclear Regulatory Commission Washington, DC 20555

, 8301040545 821227 PDR ADOCK 05000445 S PDR