TXX-3518, Interim Deficiency Rept Re Pacific Pump multi-vane Diffuser Cracking,Initially Reported 820414.Evaluation in Progress. Next Rept Will Be Provided by 820907
| ML20053A110 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 05/14/1982 |
| From: | Gary R TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Madsen G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| 10CFR-050.55E, 10CFR-50.55E, TXX-3518, NUDOCS 8205240562 | |
| Download: ML20053A110 (1) | |
Text
TEXAS UTILITIES GENERXflNG COMI%NY 2(M#1 liftYAN TOWIcit. L,AILAM.TIMAN 75201 i
R. J. GARY
"%'L2':::, :::'
m
%y s
MAY 171982 May 14, 1982 TXX-3518 Mr. G. L. Madsen, Chief Reactor Projects Branch U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement 611 Ryan Plaza Drive, Suite 1000 Docket Nos. 50-445 Arlington, TX 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION PACIFIC PUMP MULTI-VANE DIFFUSER CRACKING FILE N0:
10110 Caar Mr. Madsen:
On April 14, 1982, we verbally informed your Mr. R. G. Taylor of a deficiency identified regarding Pacific Pump multi-vane diffuser cracking.
We are continuing our evaluation and anticipate completion by September 7, 1982.
Very truly yours, kYWE
.. s R. J. Gary RJG:pko
/
cc:
NRC Region IV - (0 + 1 copy)
Director, Inspection and Enforcement - (15 copies) c/o Distribution Services Branch, DDC, ADM.
U.S. Nuclear Regulatory Commission Washington, DC 20555 fh k 4'\\0 8205240562 820514 PDR ADOCK 05000445 S
PDR J