TAC:ME2158
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
Initiation
Questions Answers | |
| From | |
MONTHYEARLR-N09-0204, Request for Relief from ASME OM Code Test Intervals for Pressure Relief2009-09-0101 September 2009
[table view]Request for Relief from ASME OM Code Test Intervals for Pressure Relief ML0925205032009-09-0909 September 2009 Acceptance Review for TAC ME2158 - Hope Creek Relief Request V-06 LR-N10-0018, Supplemental Information to Relief Request V06 to Extend the Test Intervals for Certain Class 2 and 3 Pressure Relief Valves on a One-time Basis Until Restart After Refueling Outage R162010-01-26026 January 2010 Supplemental Information to Relief Request V06 to Extend the Test Intervals for Certain Class 2 and 3 Pressure Relief Valves on a One-time Basis Until Restart After Refueling Outage R16 ML1003318162010-03-10010 March 2010 Safety Evaluation of Relief Request V-06 for the Third 10-Year Interval of the Inservice Testing Program for Hope Creek Generating Station 2009-09-09 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:ME2158&oldid=973553"